gypsum board ceiling systems - knauf astm ceiling manual.pdf · en-bs and din standards, to meet...
Post on 25-Jun-2020
13 Views
Preview:
TRANSCRIPT
2019
GYPSUM BOARD CEILING SYSTEMS
3
To our Valued Customers,
Greetings!
Knauf is a family name and a corporate group of global dimensions at the same time synonymous with a type of corporate culture which has become rare. Knauf is a typical family firm in spite of its size and this is precisely the reason for its amazing success. It is short and direct decision-making paths, the courage to tackle new ideas, innovations, investments and the wealth of ideas contributed by all Knauf employees that characterize the company.
From its beginnings in gypsum processing, Knauf has expanded and diversified to become a corporation with worldwide activities, Knauf UAE has been active in the Middle East for more than a decade.
Knauf shows its commitment not only in the GCC, headquarters in Dubai UAE, but also in the subcontinent.We have offices based in Saudi, Qatar and India to support the market and dealers.Knauf provides value-added products and services in the following fields:
• Building materials and systems based on gypsum and gypsum-related products• ASTM certified products & systems• Multi- Purpose Joint compounds• Knauf Aquapanel interior and exterior wall systems• Knauf Insulations sustainable, high-performance, cost-effective insulation solutions• Knauf Heradesign’s acoustic designs for Interior and Exterior in ceiling & partition systems• Knauf Integral’s Knauf GIFA Floor, sheet-panelled access floors• Thermal and sound insulation materials• Value engineering and technical consultancy for architects and consultants to meet specified design requirements• On site hands-on training and supervision for contractors when installing drywall systems• Knauf systems are approved by Dubai, Abu Dhabi, Ras Al Khaimah and Qatar Civil Defense
Sustainability is central to our vision of doing the right thing for our clients, our people and the communities in which we work. We maintain and provide certificates for individual products and designs to improve quality and performance. Knauf systems combine innovative products to realize speed of installation and warranted high performance-based systems as per ASTM, EN-BS and DIN Standards.
Knauf is not only committed towards it Products and System but also towards it employees. Within the framework of its four key K-Values; Partnership, Commitment, Entrepreneurship and Menschlichkeit meaning human touch Knauf looks after its people and drives a sense of passion in all its staff. This is what makes Knauf unique and special!
Safety is something that Knauf does not compromise on whether for its products or people and therefore all our products are tested and approved by Intertek to make sure that nothing leaves the plant which is not up to the mark.
Amer Bin AhmedManaging DirectorKnauf GCC & India
1) Manual Ceiling (ASTM) Feb-23-2017.indd 3 3/9/17 10:30 AM
2
Contents
04System overview
05 - 12Construction details
13General information
14Installation steps
15Processing of gypsum boards
16Joint treatment
17 - 18Cladding of boards
19Certifications
Introduction 03
1) Manual Ceiling (ASTM) Feb-23-2017.indd 2 3/9/17 10:30 AM
Manual Ceiling (ASTM)-UB.indd 2 3/29/17 6:25 PM
To Our Valued Customers,
Knauf is one of the leading voices in sourcing locally and manufacturing products that are truly “Made in UAE” as well as enabling collaboration with the major industry leaders towards technological advancements in manufactur-ing and logistics. This has made us fully equipped to efficiently cater the needs, wants and preferences of our valued customers and clients who over time have become a part of our big family.
Our commitment towards building environmentally responsible and economically sustainable products locally have been applauded, recognized and certified by esteemed UAE government authorities such as Ministry of Interiors, Civil Defense, Central Laboratory, Quality and Conformity Council.
Headquartered in Dubai, UAE, Knauf shows its customer service excellence and commitment in the Middle East and India. We ensure that the demand meets the supply, the first time and every time by utilizing our full range of flexibility and potential of our production facilities, human resources, technical expertise, logistics and cutting edge digitalisation, thereby facilitating rapid growth and development in the region.
Here is a highlight of some of Knauf’s products, systems and services:• Gypsum based high performance drywall building materials, system and accessories.• ASTM certified products & systems – Ceiling, Partition, Wall Lining and Cinema System.• Knauf Aquapanel cement boards for interior, exterior and universal usages.• Knauf Aquapanel Exterior Systems (Exterior walls, cladding and ceiling).• Knauf Heraklith’s acoustic designs for Interior and Exterior in ceiling & partition systems.• Knauf Integral’s Knauf GIFA Floor, sheet-paneled access floors systems.• Fire and acoustic rated sealants and materials.• Multi- Purpose Joint compounds.• Engineering and technical consultancy for architects, consultants, etc.• Knauf Training Academy: Hands-on training.
Knauf’s high performing, innovative systems are fast and easy to install and are manufactured to meet ASTM, EN-BS and DIN Standards, to meet any client requirements. Our dedicated Training Academy is committed to making sure that all our end users are up to date of our system.
Quality, sustainability, health and safety are central to our vision, actions towards our people and the local commu-nities ensuring every product that comes out of the line is rigorously tested, certified, approved and socio- environ-mentally responsible while producing them. Our ISO 9001 (Quality Management System), 14001 (Health, Environment and Safety), 18001 (OHSAS) and 50001 (Energy Management) certifications are a testament to our commitment to the same.
Our four dimensional core values called K-Values: Partnership, Commitment, Entrepreneurship and Menschlichkeit (“the human touch” in German) are the key drivers of our camaraderie and operational excellence throughout our multi-cultural organizational structure. It is this passion that subsequently reflects in our products and customer service excellence as well.
Thank you for being part of this big family and Let’s Build the Future together.
Amer Bin AhmedManaging DirectorKnauf Middle East & India
Global Board of Director Board of Director Intertek Certified ISO Certified
USCM
LISTED
OHSAS18001OccupationalHealth & SafetyManagement
ISO14001EnvironmentalManagement
ISO9001QualityManagement
ISO50001Energy Management
www. .ae
5
Construction details for Fire Rated Systems
These details represent some of the most common designs situations relevant to the Knauf KC A001 ceiling systems.
D) Abutment to wall, parallel to primary support channel
C) Abutment to wall, perpendicular to primary support channel
TN Screw Hat Furring Channel
Perimeter Wall fixingHammer Fixings
UD-Channel
200 mm1000 mm
Main ChannelL - angle
LN Screw
Wedge Anchor
Knauf Gypsum Board
406 mm150 mm
Hat Furring Channel
Main ChannelWire Hanger
TN Screw
Wedge Anchor
Perimeter Wall fixingHammer Fixings
UD-Channel Knauf Gypsum Board
Knauf Joint Compound
1220 mm c/c L-angle
D) Abutment to wall, parallel to primary support channel
C) Abutment to wall, perpendicular to primary support channel
These details represent some of the most common designs situations relevant to theKnauf KC A001 ceiling systems.
Construction details for Non Fire Rated Systems
TN Screw Hat Furring Channel
Perimeter Wall fixingHammer Fixings
UD-Channel
200 mm1000 mm
Main ChannelL - angle
LN Screw
Wedge Anchor
Knauf Gypsum Board
406 mm150 mm
Hat Furring Channel
Main ChannelWire Hanger
TN Screw
Wedge Anchor
Perimeter Wall fixingHammer Fixings
UD-Channel Knauf Gypsum Board
Knauf Joint Compound
1220 mm c/c L-angle
D) Abutment to wall, parallel to primary support channel
C) Abutment to wall, perpendicular to primary support channel
These details represent some of the most common designs situations relevant to theKnauf KC A001 ceiling systems.
Construction details for Non Fire Rated Systems
1) Manual Ceiling (ASTM) Feb-23-2017.indd 5 3/9/17 10:30 AM
4
System overview
600 mm
600 mm
406
1000 mm
1220 mm
200
150
406
406
Hat Furring Channel
L - angle
Main Channel Access Opening
Gypsum Board
Perimeter WallUD - Channel
* Fire Protection to Floor or Roof Cavity above* Fire Protection to Steel Beams Supporting Concrete Floors
Spacing of StructureCladding
ThicknessFire
ResistanceSuspensionHangers (mm)
UpperChannels (mm)
FurringChannels (mm)
Knauf Fire Resistant & Non Fire Resistant, Ceiling Assemblies,Tested in accordance to ASTM E-119
Construction details
1 x 12.7 mm -
60 min.1 x 15.9 mm -
120 min.
1220 mm
1220 mm
1000 mm
1000 mm
406 mm
406 mm*2 x 12.7 mm
*2 x 15.9 mm
*Boards types: Knauf Type-X Boards
A) Splicing of Main Channel B) Splicing of furring channel
A) Splicing of Main Channel B) Splicing of furring channel
609 mm
Overlap
38
12.5
Hat Furring ChannelSplicing / End to End Connection
406 mm
Hat Furring Channel
LN Screw
A) Splicing of Main Channel B) Splicing of furring channel
609 mm
Overlap
38
12.5
Hat Furring ChannelSplicing / End to End Connection
406 mm
Hat Furring Channel
LN Screw
A) Splicing of Main Channel B) Splicing of furring channel
609 mm
Overlap
38
12.5
Hat Furring ChannelSplicing / End to End Connection
406 mm
Hat Furring Channel
LN Screw
1) Manual Ceiling (ASTM) Feb-23-2017.indd 4 3/9/17 10:30 AM
Manual Ceiling (ASTM)-UB.indd 4 3/29/17 6:25 PM
5
Construction details for Fire Rated Systems
These details represent some of the most common designs situations relevant to the Knauf KC A001 ceiling systems.
D) Abutment to wall, parallel to primary support channel
C) Abutment to wall, perpendicular to primary support channel
TN Screw Hat Furring Channel
Perimeter Wall fixingHammer Fixings
UD-Channel
200 mm1000 mm
Main ChannelL - angle
LN Screw
Wedge Anchor
Knauf Gypsum Board
406 mm150 mm
Hat Furring Channel
Main ChannelWire Hanger
TN Screw
Wedge Anchor
Perimeter Wall fixingHammer Fixings
UD-Channel Knauf Gypsum Board
Knauf Joint Compound
1220 mm c/c L-angle
D) Abutment to wall, parallel to primary support channel
C) Abutment to wall, perpendicular to primary support channel
These details represent some of the most common designs situations relevant to theKnauf KC A001 ceiling systems.
Construction details for Non Fire Rated Systems
TN Screw Hat Furring Channel
Perimeter Wall fixingHammer Fixings
UD-Channel
200 mm1000 mm
Main ChannelL - angle
LN Screw
Wedge Anchor
Knauf Gypsum Board
406 mm150 mm
Hat Furring Channel
Main ChannelWire Hanger
TN Screw
Wedge Anchor
Perimeter Wall fixingHammer Fixings
UD-Channel Knauf Gypsum Board
Knauf Joint Compound
1220 mm c/c L-angle
D) Abutment to wall, parallel to primary support channel
C) Abutment to wall, perpendicular to primary support channel
These details represent some of the most common designs situations relevant to theKnauf KC A001 ceiling systems.
Construction details for Non Fire Rated Systems
1) Manual Ceiling (ASTM) Feb-23-2017.indd 5 3/9/17 10:30 AM
4
System overview
600 mm
600 mm
406
1000 mm
1220 mm
200
150
406
406
Hat Furring Channel
L - angle
Main Channel Access Opening
Gypsum Board
Perimeter WallUD - Channel
* Fire Protection to Floor or Roof Cavity above* Fire Protection to Steel Beams Supporting Concrete Floors
Spacing of StructureCladding
ThicknessFire
ResistanceSuspensionHangers (mm)
UpperChannels (mm)
FurringChannels (mm)
Knauf Fire Resistant & Non Fire Resistant, Ceiling Assemblies,Tested in accordance to ASTM E-119
Construction details
1 x 12.7 mm -
60 min.1 x 15.9 mm -
120 min.
1220 mm
1220 mm
1000 mm
1000 mm
406 mm
406 mm*2 x 12.7 mm
*2 x 15.9 mm
*Boards types: Knauf Type-X Boards
A) Splicing of Main Channel B) Splicing of furring channel
A) Splicing of Main Channel B) Splicing of furring channel
609 mm
Overlap
38
12.5
Hat Furring ChannelSplicing / End to End Connection
406 mm
Hat Furring Channel
LN Screw
A) Splicing of Main Channel B) Splicing of furring channel
609 mm
Overlap
38
12.5
Hat Furring ChannelSplicing / End to End Connection
406 mm
Hat Furring Channel
LN Screw
A) Splicing of Main Channel B) Splicing of furring channel
609 mm
Overlap
38
12.5
Hat Furring ChannelSplicing / End to End Connection
406 mm
Hat Furring Channel
LN Screw
1) Manual Ceiling (ASTM) Feb-23-2017.indd 4 3/9/17 10:30 AM
Manual Ceiling (ASTM)-UB.indd 5 3/29/17 6:25 PM
7
Construction details for Fire Rated Systems
H) Movement control joint
G) Change of level and bulkhead
Construction details for Fire Rated Systems
G) Change of level and bulkhead
H) Movement control joint
Hat Furring Channel
Main Channel
L - angleLN Screw
TN Screw Knauf MovementControl Joint
Knauf Approved Fixing
Main Channel
UD-Channel
Hat Furring ChannelKnauf Gypsum Board
Hat FurringChannel
Perimeter Wall fixingHammer Fixings
UD-Channel
L - Angle
LN Screw
Wedge Anchor
Fire Sealant
200 mm
UD-Channel
TN Screw
Construction details for Fire Rated Systems
G) Change of level and bulkhead
H) Movement control joint
Hat Furring Channel
Main Channel
L - angleLN Screw
TN Screw Knauf MovementControl Joint
Knauf Approved Fixing
Main Channel
UD-Channel
Hat Furring ChannelKnauf Gypsum Board
Hat FurringChannel
Perimeter Wall fixingHammer Fixings
UD-Channel
L - Angle
LN Screw
Wedge Anchor
Fire Sealant
200 mm
UD-Channel
TN Screw
1) Manual Ceiling (ASTM) Feb-23-2017.indd 7 3/9/17 10:30 AM
6
Construction details for Fire Rated Systems
Construction details
F) Abutment to wall, parallel to primary support channel, double layer
E) Optional Suspension Support
Option - 1 Option - 2
Construction details for Fire Rated Systems
TN ScrewLN ScrewKnauf Gypsum Board
TN Screw
Knauf Gypsum Board
Hat Furring Channel
L-Angle
Main ChannelWire Hanger
Wedge Anchor
F) Abutment to wall, parallel to primary support channel, double layer
E) Optional Suspension Support
Option - 1 Option - 2
Construction details
406 mm150 mm
Hat Furring Channel
Main ChannelL - angle
TN Screw
LN Screw
Wedge Anchor
1220 mm c/c L-angle
UD-Channel
Perimeter Wall fixingHammer Fixings
Knauf Gypsum Board
Knauf Joint Compound
Construction details for Fire Rated Systems
TN ScrewLN ScrewKnauf Gypsum Board
TN Screw
Knauf Gypsum Board
Hat Furring Channel
L-Angle
Main ChannelWire Hanger
Wedge Anchor
F) Abutment to wall, parallel to primary support channel, double layer
E) Optional Suspension Support
Option - 1 Option - 2
Construction details
406 mm150 mm
Hat Furring Channel
Main ChannelL - angle
TN Screw
LN Screw
Wedge Anchor
1220 mm c/c L-angle
UD-Channel
Perimeter Wall fixingHammer Fixings
Knauf Gypsum Board
Knauf Joint Compound
1) Manual Ceiling (ASTM) Feb-23-2017.indd 6 3/9/17 10:30 AM
Manual Ceiling (ASTM)-UB.indd 6 3/29/17 6:25 PM
7
Construction details for Fire Rated Systems
H) Movement control joint
G) Change of level and bulkhead
Construction details for Fire Rated Systems
G) Change of level and bulkhead
H) Movement control joint
Hat Furring Channel
Main Channel
L - angleLN Screw
TN Screw Knauf MovementControl Joint
Knauf Approved Fixing
Main Channel
UD-Channel
Hat Furring ChannelKnauf Gypsum Board
Hat FurringChannel
Perimeter Wall fixingHammer Fixings
UD-Channel
L - Angle
LN Screw
Wedge Anchor
Fire Sealant
200 mm
UD-Channel
TN Screw
Construction details for Fire Rated Systems
G) Change of level and bulkhead
H) Movement control joint
Hat Furring Channel
Main Channel
L - angleLN Screw
TN Screw Knauf MovementControl Joint
Knauf Approved Fixing
Main Channel
UD-Channel
Hat Furring ChannelKnauf Gypsum Board
Hat FurringChannel
Perimeter Wall fixingHammer Fixings
UD-Channel
L - Angle
LN Screw
Wedge Anchor
Fire Sealant
200 mm
UD-Channel
TN Screw
1) Manual Ceiling (ASTM) Feb-23-2017.indd 7 3/9/17 10:30 AM
6
Construction details for Fire Rated Systems
Construction details
F) Abutment to wall, parallel to primary support channel, double layer
E) Optional Suspension Support
Option - 1 Option - 2
Construction details for Fire Rated Systems
TN ScrewLN ScrewKnauf Gypsum Board
TN Screw
Knauf Gypsum Board
Hat Furring Channel
L-Angle
Main ChannelWire Hanger
Wedge Anchor
F) Abutment to wall, parallel to primary support channel, double layer
E) Optional Suspension Support
Option - 1 Option - 2
Construction details
406 mm150 mm
Hat Furring Channel
Main ChannelL - angle
TN Screw
LN Screw
Wedge Anchor
1220 mm c/c L-angle
UD-Channel
Perimeter Wall fixingHammer Fixings
Knauf Gypsum Board
Knauf Joint Compound
Construction details for Fire Rated Systems
TN ScrewLN ScrewKnauf Gypsum Board
TN Screw
Knauf Gypsum Board
Hat Furring Channel
L-Angle
Main ChannelWire Hanger
Wedge Anchor
F) Abutment to wall, parallel to primary support channel, double layer
E) Optional Suspension Support
Option - 1 Option - 2
Construction details
406 mm150 mm
Hat Furring Channel
Main ChannelL - angle
TN Screw
LN Screw
Wedge Anchor
1220 mm c/c L-angle
UD-Channel
Perimeter Wall fixingHammer Fixings
Knauf Gypsum Board
Knauf Joint Compound
1) Manual Ceiling (ASTM) Feb-23-2017.indd 6 3/9/17 10:30 AM
Manual Ceiling (ASTM)-UB.indd 7 3/29/17 6:25 PM
9
Construction details for Non Fire Rated Systems
L) Abutment to wall, parallel to primary support channel
K) Optional Suspension Support
Option - 1 Option - 2
L) Abutment to wall, parallel to primary support channel
K) Optional Suspension Support
Option - 1 Option - 2
These details represent some of the most common designs situations relevant to theKnauf KC A001 ceiling systems.
TN Screw Hat Furring Channel
Main ChannelWire HangerL-Angle
LN Screw
Wedge Anchor
Knauf Gypsum Board
Construction details for Non Fire Rated Systems
Knauf Joint Compound
406 mm150 mm
Hat Furring Channel
Main ChannelL - angle
TN Screw
LN Screw
Wedge Anchor
Knauf Gypsum Board
1220 mm c/c L-angle
UD-Channel
Perimeter Wall fixingHammer Fixings
L) Abutment to wall, parallel to primary support channel
K) Optional Suspension Support
Option - 1 Option - 2
These details represent some of the most common designs situations relevant to theKnauf KC A001 ceiling systems.
TN Screw Hat Furring Channel
Main ChannelWire HangerL-Angle
LN Screw
Wedge Anchor
Knauf Gypsum Board
Construction details for Non Fire Rated Systems
Knauf Joint Compound
406 mm150 mm
Hat Furring Channel
Main ChannelL - angle
TN Screw
LN Screw
Wedge Anchor
Knauf Gypsum Board
1220 mm c/c L-angle
UD-Channel
Perimeter Wall fixingHammer Fixings
These details represent some of the most common designs situations relevant to the Knauf KC A001 ceiling systems.
1) Manual Ceiling (ASTM) Feb-23-2017.indd 9 3/9/17 10:30 AM
8
Construction details for Fire Rated Systems
J) Reinforcement of Board Joints
I) Junction with partition
Construction details for Fire Rated Systems
J) Reinforcement of Board Joints (Square edge only)
I) Junction with partition
Main ChannelUD-Channel
L - Angle
LN Screw
Wedge Anchor
50 mm
Wedge Anchor
Hat Furring Channel
Knauf Gypsum Board
50 mm
Fire Sealant TN Screw
For Fire Resistant System
Main Channel
Hat Furring Channel
TN Screw
Knauf Gypsum Board Knauf Joint Compound
Construction details for Fire Rated Systems
J) Reinforcement of Board Joints (Square edge only)
I) Junction with partition
Main ChannelUD-Channel
L - Angle
LN Screw
Wedge Anchor
50 mm
Wedge Anchor
Hat Furring Channel
Knauf Gypsum Board
50 mm
Fire Sealant TN Screw
For Fire Resistant System
Main Channel
Hat Furring Channel
TN Screw
Knauf Gypsum Board Knauf Joint Compound
1) Manual Ceiling (ASTM) Feb-23-2017.indd 8 3/9/17 10:30 AM
Manual Ceiling (ASTM)-UB.indd 8 3/29/17 6:25 PM
9
Construction details for Non Fire Rated Systems
L) Abutment to wall, parallel to primary support channel
K) Optional Suspension Support
Option - 1 Option - 2
L) Abutment to wall, parallel to primary support channel
K) Optional Suspension Support
Option - 1 Option - 2
These details represent some of the most common designs situations relevant to theKnauf KC A001 ceiling systems.
TN Screw Hat Furring Channel
Main ChannelWire HangerL-Angle
LN Screw
Wedge Anchor
Knauf Gypsum Board
Construction details for Non Fire Rated Systems
Knauf Joint Compound
406 mm150 mm
Hat Furring Channel
Main ChannelL - angle
TN Screw
LN Screw
Wedge Anchor
Knauf Gypsum Board
1220 mm c/c L-angle
UD-Channel
Perimeter Wall fixingHammer Fixings
L) Abutment to wall, parallel to primary support channel
K) Optional Suspension Support
Option - 1 Option - 2
These details represent some of the most common designs situations relevant to theKnauf KC A001 ceiling systems.
TN Screw Hat Furring Channel
Main ChannelWire HangerL-Angle
LN Screw
Wedge Anchor
Knauf Gypsum Board
Construction details for Non Fire Rated Systems
Knauf Joint Compound
406 mm150 mm
Hat Furring Channel
Main ChannelL - angle
TN Screw
LN Screw
Wedge Anchor
Knauf Gypsum Board
1220 mm c/c L-angle
UD-Channel
Perimeter Wall fixingHammer Fixings
These details represent some of the most common designs situations relevant to the Knauf KC A001 ceiling systems.
1) Manual Ceiling (ASTM) Feb-23-2017.indd 9 3/9/17 10:30 AM
8
Construction details for Fire Rated Systems
J) Reinforcement of Board Joints
I) Junction with partition
Construction details for Fire Rated Systems
J) Reinforcement of Board Joints (Square edge only)
I) Junction with partition
Main ChannelUD-Channel
L - Angle
LN Screw
Wedge Anchor
50 mm
Wedge Anchor
Hat Furring Channel
Knauf Gypsum Board
50 mm
Fire Sealant TN Screw
For Fire Resistant System
Main Channel
Hat Furring Channel
TN Screw
Knauf Gypsum Board Knauf Joint Compound
Construction details for Fire Rated Systems
J) Reinforcement of Board Joints (Square edge only)
I) Junction with partition
Main ChannelUD-Channel
L - Angle
LN Screw
Wedge Anchor
50 mm
Wedge Anchor
Hat Furring Channel
Knauf Gypsum Board
50 mm
Fire Sealant TN Screw
For Fire Resistant System
Main Channel
Hat Furring Channel
TN Screw
Knauf Gypsum Board Knauf Joint Compound
1) Manual Ceiling (ASTM) Feb-23-2017.indd 8 3/9/17 10:30 AM
Manual Ceiling (ASTM)-UB.indd 9 3/29/17 6:25 PM
11
P) Movement control joint
O) Change of level and bulkhead
Construction details for Non Fire Rated Systems
O) Change of level and bulkhead
P) Movement control joint
Main Channel
UD-Channel
Hat Furring ChannelKnauf Gypsum Board
Hat FurringChannel
Perimeter Wall fixingHammer Fixings
UD-Channel
L - Angle
LN Screw
Wedge Anchor
Fire Sealant
200 mm
UD-Channel
TN Screw
Hat Furring Channel
Main Channel
L - angleLN Screw
TN Screw Knauf MovementControl Joint
Knauf Approved Fixing
Construction details for Non Fire Rated Systems
O) Change of level and bulkhead
P) Movement control joint
Main Channel
UD-Channel
Hat Furring ChannelKnauf Gypsum Board
Hat FurringChannel
Perimeter Wall fixingHammer Fixings
UD-Channel
L - Angle
LN Screw
Wedge Anchor
Fire Sealant
200 mm
UD-Channel
TN Screw
Hat Furring Channel
Main Channel
L - angleLN Screw
TN Screw Knauf MovementControl Joint
Knauf Approved Fixing
Construction details for Non Fire Rated Systems
1) Manual Ceiling (ASTM) Feb-23-2017.indd 11 3/9/17 10:30 AM
1 0
These details represent some of the most common designs situations relevant to the Knauf KC A001 ceiling systems.
N) Abutment to wall, parallel to primary support channel
M) Abutment to wall, perpendicular to primary support channel
N) Abutment to wall, parallel to primary support channel
M) Abutment to wall, perpendicular to primary support channel
These details represent some of the most common designs situations relevant to theKnauf KC A001 ceiling systems.
Construction details for Non Fire Rated Systems
406 mm150 mmHat Furring Channel
Main ChannelWire Hanger
TN Screw
Wedge Anchor
UD-Channel Knauf Gypsum Board
Knauf Joint Compound
1220 mm c/c L-angle
Perimeter Wall fixingHammer Fixings
TN Screw Hat Furring Channel
Perimeter Wall fixingHammer Fixings
UD-Channel
200 mm1000 mm
Main ChannelL - angle
LN Screw
Wedge Anchor
Knauf Gypsum Board
N) Abutment to wall, parallel to primary support channel
M) Abutment to wall, perpendicular to primary support channel
These details represent some of the most common designs situations relevant to theKnauf KC A001 ceiling systems.
Construction details for Non Fire Rated Systems
406 mm150 mmHat Furring Channel
Main ChannelWire Hanger
TN Screw
Wedge Anchor
UD-Channel Knauf Gypsum Board
Knauf Joint Compound
1220 mm c/c L-angle
Perimeter Wall fixingHammer Fixings
TN Screw Hat Furring Channel
Perimeter Wall fixingHammer Fixings
UD-Channel
200 mm1000 mm
Main ChannelL - angle
LN Screw
Wedge Anchor
Knauf Gypsum Board
Construction details for Non Fire Rated Systems
1) Manual Ceiling (ASTM) Feb-23-2017.indd 10 3/9/17 10:30 AM
Manual Ceiling (ASTM)-UB.indd 10 3/29/17 6:25 PM
11
P) Movement control joint
O) Change of level and bulkhead
Construction details for Non Fire Rated Systems
O) Change of level and bulkhead
P) Movement control joint
Main Channel
UD-Channel
Hat Furring ChannelKnauf Gypsum Board
Hat FurringChannel
Perimeter Wall fixingHammer Fixings
UD-Channel
L - Angle
LN Screw
Wedge Anchor
Fire Sealant
200 mm
UD-Channel
TN Screw
Hat Furring Channel
Main Channel
L - angleLN Screw
TN Screw Knauf MovementControl Joint
Knauf Approved Fixing
Construction details for Non Fire Rated Systems
O) Change of level and bulkhead
P) Movement control joint
Main Channel
UD-Channel
Hat Furring ChannelKnauf Gypsum Board
Hat FurringChannel
Perimeter Wall fixingHammer Fixings
UD-Channel
L - Angle
LN Screw
Wedge Anchor
Fire Sealant
200 mm
UD-Channel
TN Screw
Hat Furring Channel
Main Channel
L - angleLN Screw
TN Screw Knauf MovementControl Joint
Knauf Approved Fixing
Construction details for Non Fire Rated Systems
1) Manual Ceiling (ASTM) Feb-23-2017.indd 11 3/9/17 10:30 AM
1 0
These details represent some of the most common designs situations relevant to the Knauf KC A001 ceiling systems.
N) Abutment to wall, parallel to primary support channel
M) Abutment to wall, perpendicular to primary support channel
N) Abutment to wall, parallel to primary support channel
M) Abutment to wall, perpendicular to primary support channel
These details represent some of the most common designs situations relevant to theKnauf KC A001 ceiling systems.
Construction details for Non Fire Rated Systems
406 mm150 mmHat Furring Channel
Main ChannelWire Hanger
TN Screw
Wedge Anchor
UD-Channel Knauf Gypsum Board
Knauf Joint Compound
1220 mm c/c L-angle
Perimeter Wall fixingHammer Fixings
TN Screw Hat Furring Channel
Perimeter Wall fixingHammer Fixings
UD-Channel
200 mm1000 mm
Main ChannelL - angle
LN Screw
Wedge Anchor
Knauf Gypsum Board
N) Abutment to wall, parallel to primary support channel
M) Abutment to wall, perpendicular to primary support channel
These details represent some of the most common designs situations relevant to theKnauf KC A001 ceiling systems.
Construction details for Non Fire Rated Systems
406 mm150 mmHat Furring Channel
Main ChannelWire Hanger
TN Screw
Wedge Anchor
UD-Channel Knauf Gypsum Board
Knauf Joint Compound
1220 mm c/c L-angle
Perimeter Wall fixingHammer Fixings
TN Screw Hat Furring Channel
Perimeter Wall fixingHammer Fixings
UD-Channel
200 mm1000 mm
Main ChannelL - angle
LN Screw
Wedge Anchor
Knauf Gypsum Board
Construction details for Non Fire Rated Systems
1) Manual Ceiling (ASTM) Feb-23-2017.indd 10 3/9/17 10:30 AM
Manual Ceiling (ASTM)-UB.indd 11 3/29/17 6:25 PM
13
GeneralKnauf KC A001 Ceiling Systems must be installed inaccordance with Knauf 's recommendations. When creating an airtight space, methods for the reduction of potential “ceiling lift ’’ should be considered.
Perimeter FixingMark the position of the ceiling line with a Chalk Line (1). Knauf UD channels should be secured to the walls at the required heights, at maximum 609mm centers and 50mm from the ends of channels. The Knauf UD forming the perimeter and the Knauf Main C Channels do not need to be mechanically fixed together (2).
SuspensionSelect the fixing centers suited to the ceiling loading. See page 3 for spacing of dowels.Fix Knauf approved fixing to the structural soffit with suitable fixings. Use the Knauf L Angle and fix to the approved fixing dowel (3).
Primary Support Channels – C ChannelsThe centers of the primary support channels should be aligned at the required height.Knauf L Angle should be fixed to the Knauf Main C Channels with two Knauf LN Wafer Head Screws (4).
Splicing of the Main C ChannelsIf straight lengths of Knauf Main C Channelsneed jointing, place the channels back toback, with a minimum 609 mm overlap, and fix withtwo Knauf LN Wafer Head Screws.
Hat Furring ChannelsThe Knauf Hat Furring Channels should bepositioned at 406mm centers within the perimeterchannels to coincide with the abutments of theboards, which will be fixed later. Connect the Knauf Hat Furring Channels to the Knauf Main C Channel by means of Knauf LN Wafer Head Screws (5).
InsulationIf insulation is required, once the primary support and the ceiling channels have been connected and before the boarding has started, Knauf insulation as specified should be inserted above the primary support channels. Care should be taken to ensure that the insulation is fitted neatly without gaps at abutments or between different rolls.
Movement Control JointsCreate movement control joints where ceilingruns exceed 10m, coinciding where possible with movement joints in the surrounding structure.
BoardingAll boards should be fixed to the ceiling gridwith the decorative face of the boards outwards and secured with Knauf Screws at maximum 203 mm centers (6).Boards should be mounted at 90° to the direction of the ceiling channels (7).Second layer should be installer with staggered joints.as shown in details (J) page 8
General information
Where the cut end of Gypsum board end’s Reinforcement through the inclusion of additional Hat Furring Channels should be implemented. A piece of Hat Furring channel should be located approx. 1 inch back from each board edge.
(Only for Fire Resistant System)Board Joint Reinforcement
1) Manual Ceiling (ASTM) Feb-23-2017.indd 13 3/9/17 10:30 AM
1 2
R) Reinforcement of Board Joint
Q) Junction with Partition
Construction details for Non Fire Rated Systems
R) Reinforcement of Board Joint (Square edge Only)
Q) Junction with Partition
Main ChannelHat Furring Channel
TN ScrewKnauf Gypsum Board Knauf Joint Compound
TN Screw
Hat Furring ChannelFire SealantUD-Channel
Main Channel
LN Screw
L - angle
Wedge Anchor
Knauf Gypsum Board
Knauf UW Runner
Knauf CW Stud
Knauf Drywall Screw
Knauf Gypsum Board
Insulation Material
50 mm 50 mm
Construction details for Non Fire Rated Systems
R) Reinforcement of Board Joint (Square edge Only)
Q) Junction with Partition
Main ChannelHat Furring Channel
TN ScrewKnauf Gypsum Board Knauf Joint Compound
TN Screw
Hat Furring ChannelFire SealantUD-Channel
Main Channel
LN Screw
L - angle
Wedge Anchor
Knauf Gypsum Board
Knauf UW Runner
Knauf CW Stud
Knauf Drywall Screw
Knauf Gypsum Board
Insulation Material
50 mm 50 mm
Construction details for Non Fire Rated Systems
1) Manual Ceiling (ASTM) Feb-23-2017.indd 12 3/9/17 10:30 AM
Manual Ceiling (ASTM)-UB.indd 12 3/29/17 6:25 PM
13
GeneralKnauf KC A001 Ceiling Systems must be installed inaccordance with Knauf 's recommendations. When creating an airtight space, methods for the reduction of potential “ceiling lift ’’ should be considered.
Perimeter FixingMark the position of the ceiling line with a Chalk Line (1). Knauf UD channels should be secured to the walls at the required heights, at maximum 609mm centers and 50mm from the ends of channels. The Knauf UD forming the perimeter and the Knauf Main C Channels do not need to be mechanically fixed together (2).
SuspensionSelect the fixing centers suited to the ceiling loading. See page 3 for spacing of dowels.Fix Knauf approved fixing to the structural soffit with suitable fixings. Use the Knauf L Angle and fix to the approved fixing dowel (3).
Primary Support Channels – C ChannelsThe centers of the primary support channels should be aligned at the required height.Knauf L Angle should be fixed to the Knauf Main C Channels with two Knauf LN Wafer Head Screws (4).
Splicing of the Main C ChannelsIf straight lengths of Knauf Main C Channelsneed jointing, place the channels back toback, with a minimum 609 mm overlap, and fix withtwo Knauf LN Wafer Head Screws.
Hat Furring ChannelsThe Knauf Hat Furring Channels should bepositioned at 406mm centers within the perimeterchannels to coincide with the abutments of theboards, which will be fixed later. Connect the Knauf Hat Furring Channels to the Knauf Main C Channel by means of Knauf LN Wafer Head Screws (5).
InsulationIf insulation is required, once the primary support and the ceiling channels have been connected and before the boarding has started, Knauf insulation as specified should be inserted above the primary support channels. Care should be taken to ensure that the insulation is fitted neatly without gaps at abutments or between different rolls.
Movement Control JointsCreate movement control joints where ceilingruns exceed 10m, coinciding where possible with movement joints in the surrounding structure.
BoardingAll boards should be fixed to the ceiling gridwith the decorative face of the boards outwards and secured with Knauf Screws at maximum 203 mm centers (6).Boards should be mounted at 90° to the direction of the ceiling channels (7).Second layer should be installer with staggered joints.as shown in details (J) page 8
General information
Where the cut end of Gypsum board end’s Reinforcement through the inclusion of additional Hat Furring Channels should be implemented. A piece of Hat Furring channel should be located approx. 1 inch back from each board edge.
(Only for Fire Resistant System)Board Joint Reinforcement
1) Manual Ceiling (ASTM) Feb-23-2017.indd 13 3/9/17 10:30 AM
1 2
R) Reinforcement of Board Joint
Q) Junction with Partition
Construction details for Non Fire Rated Systems
R) Reinforcement of Board Joint (Square edge Only)
Q) Junction with Partition
Main ChannelHat Furring Channel
TN ScrewKnauf Gypsum Board Knauf Joint Compound
TN Screw
Hat Furring ChannelFire SealantUD-Channel
Main Channel
LN Screw
L - angle
Wedge Anchor
Knauf Gypsum Board
Knauf UW Runner
Knauf CW Stud
Knauf Drywall Screw
Knauf Gypsum Board
Insulation Material
50 mm 50 mm
Construction details for Non Fire Rated Systems
R) Reinforcement of Board Joint (Square edge Only)
Q) Junction with Partition
Main ChannelHat Furring Channel
TN ScrewKnauf Gypsum Board Knauf Joint Compound
TN Screw
Hat Furring ChannelFire SealantUD-Channel
Main Channel
LN Screw
L - angle
Wedge Anchor
Knauf Gypsum Board
Knauf UW Runner
Knauf CW Stud
Knauf Drywall Screw
Knauf Gypsum Board
Insulation Material
50 mm 50 mm
Construction details for Non Fire Rated Systems
1) Manual Ceiling (ASTM) Feb-23-2017.indd 12 3/9/17 10:30 AM
Manual Ceiling (ASTM)-UB.indd 13 3/29/17 6:25 PM
15
Cut the paper face with a sharp knife
Cut the board 45 degrees Smooth the cut edge with a beveler
Processing of gypsum boards
Cutting and processing the boards
nKnauf Boards shall be cut by scoring and breaking or by sawingnWhen cutting by scoring, the face paper shall be cut with a utility knifenKnauf boards shall be broken by snapping boards in the reverse direction, then cutting the back paper with a utility knifenCut edges should be smoothed with Knauf Beveler / Rasp Combo to obtain neat joints when installednShort edges should be chamfered with Knauf Beveler / Rasp CombonHoles for pipes or other small openings shall be scored on the back and the face outlined before removal / cut out with a purposely designed tool
Score the board by pushing along the cut side, then cut the other paper side
1) Manual Ceiling (ASTM) Feb-23-2017.indd 15 3/9/17 10:31 AM
1 4
1
4
6 7
2
5
3Mark the position of the ceiling line (deducting the thickness of the boards) with a Chalk Line.
Fix the UD channel on the perimeter (at 609mm centers and 50mm from end of channel).
Predrill the holes for the
the dowel (e.g. Wedge Anchor) at the recommended spacing.
Knauf Main C Channels should
Knauf LN Wafer Head Screws at the desired length.
Connect the Knauf Hat Furring Channels to the Knauf Main C Channel by means of Knauf LN Wafer Head Screws
Fix the boards to the furring channel with Knauf screws.max. 203 mm.
Installation steps
1) Manual Ceiling (ASTM) Feb-23-2017.indd 14 3/9/17 10:30 AM
Manual Ceiling (ASTM)-UB.indd 14 3/29/17 6:25 PM
15
Cut the paper face with a sharp knife
Cut the board 45 degrees Smooth the cut edge with a beveler
Processing of gypsum boards
Cutting and processing the boards
nKnauf Boards shall be cut by scoring and breaking or by sawingnWhen cutting by scoring, the face paper shall be cut with a utility knifenKnauf boards shall be broken by snapping boards in the reverse direction, then cutting the back paper with a utility knifenCut edges should be smoothed with Knauf Beveler / Rasp Combo to obtain neat joints when installednShort edges should be chamfered with Knauf Beveler / Rasp CombonHoles for pipes or other small openings shall be scored on the back and the face outlined before removal / cut out with a purposely designed tool
Score the board by pushing along the cut side, then cut the other paper side
1) Manual Ceiling (ASTM) Feb-23-2017.indd 15 3/9/17 10:31 AM
1 4
1
4
6 7
2
5
3Mark the position of the ceiling line (deducting the thickness of the boards) with a Chalk Line.
Fix the UD channel on the perimeter (at 609mm centers and 50mm from end of channel).
Predrill the holes for the
the dowel (e.g. Wedge Anchor) at the recommended spacing.
Knauf Main C Channels should
Knauf LN Wafer Head Screws at the desired length.
Connect the Knauf Hat Furring Channels to the Knauf Main C Channel by means of Knauf LN Wafer Head Screws
Fix the boards to the furring channel with Knauf screws.max. 203 mm.
Installation steps
1) Manual Ceiling (ASTM) Feb-23-2017.indd 14 3/9/17 10:30 AM
Manual Ceiling (ASTM)-UB.indd 15 3/29/17 6:25 PM
17
Boards should be mounted at 90° to the direction of the ceiling channels.In case of multi layer cladding, apply layers with staggered joints according to application scheme.
.
Single / First layer cladding
Fastening of claddingSpacing of screws
Screw Spacing second layer: 203 mm
Second layerFirst layerBoard thickness
TN 3.9X35 mmTN 3.9X25 mm12.7 mm
TN 3.9X45 mmTN 3.9X25 mm15.9 mm
2436
1220
1220
1220
406406406406
203
203
203
203
406 4062436 mm
1000
Cladding of boards
1) Manual Ceiling (ASTM) Feb-23-2017.indd 17 3/9/17 10:31 AM
1 6
Joint treatment
Cutting and processing the boardsnBoard surface should be cleaned of materials such as dust, oil etc.nFilling and covering of joints should only take place after the boards have been allowed to rest in the given humidity and temperature zones, and no more longitudinal changes can be expected, i.e. expansion or contraction.
nFirst coat of Knauf Joint filler should be applied with tools of sufficient width to extend a minimum 50 mm beyond both sides of the center of the joint (100 mm width).nKnauf Joint Tape should be embedded into the joint filler to reinforce the joint between two gypsum boards.nOnce the first coat has dried, a second coat of Knauf Joint filler should be applied with 100 mm width on both sides of the center of the joint tape (200 mm width).nA very thin third coat of Knauf Joint filler should be applied with a minimum width no less than 150 mm beyond both sides of the center of the joint tape (300 mm width).nOnce third coat has dried, surface should be sanded and smoothed.
1) Manual Ceiling (ASTM) Feb-23-2017.indd 16 3/9/17 10:31 AM
Manual Ceiling (ASTM)-UB.indd 16 3/29/17 6:25 PM
17
Boards should be mounted at 90° to the direction of the ceiling channels.In case of multi layer cladding, apply layers with staggered joints according to application scheme.
.
Single / First layer cladding
Fastening of claddingSpacing of screws
Screw Spacing second layer: 203 mm
Second layerFirst layerBoard thickness
TN 3.9X35 mmTN 3.9X25 mm12.7 mm
TN 3.9X45 mmTN 3.9X25 mm15.9 mm
2436
1220
1220
1220
406406406406
203
203
203
203
406 4062436 mm
1000
Cladding of boards
1) Manual Ceiling (ASTM) Feb-23-2017.indd 17 3/9/17 10:31 AM
1 6
Joint treatment
Cutting and processing the boardsnBoard surface should be cleaned of materials such as dust, oil etc.nFilling and covering of joints should only take place after the boards have been allowed to rest in the given humidity and temperature zones, and no more longitudinal changes can be expected, i.e. expansion or contraction.
nFirst coat of Knauf Joint filler should be applied with tools of sufficient width to extend a minimum 50 mm beyond both sides of the center of the joint (100 mm width).nKnauf Joint Tape should be embedded into the joint filler to reinforce the joint between two gypsum boards.nOnce the first coat has dried, a second coat of Knauf Joint filler should be applied with 100 mm width on both sides of the center of the joint tape (200 mm width).nA very thin third coat of Knauf Joint filler should be applied with a minimum width no less than 150 mm beyond both sides of the center of the joint tape (300 mm width).nOnce third coat has dried, surface should be sanded and smoothed.
1) Manual Ceiling (ASTM) Feb-23-2017.indd 16 3/9/17 10:31 AM
Manual Ceiling (ASTM)-UB.indd 17 3/29/17 6:25 PM
19
Regional Materials On a range of 500 miles from factory and quarry location, our boards can provide points for regional materials mentioned in different evaluation criteria (LEED, Estidama, etc.).
Total VOC content
Our boards have been tested for total Volatile Organic Compounds emissions. Detected amount: below 0.05 mg/kg.
Certificate of RegistrationQUALITY MANAGEMENT SYSTEM - ISO 9001:2008
This is to certify that: Knauf LLCPO Box 112871DubaiUnited Arab Emirates
Holds Certificate No: FM 577441
and operates a Quality Management System which complies with the requirements of ISO 9001:2008 for thefollowing scope:
The production of Metal Profiles, Plasters, Plasterboards, Ready Fix and all supporting activitieswithin the Middle East.
For and on behalf of BSI:Gary Fenton, Global Assurance Director
Originally registered: 09/11/2011 Latest Issue: 25/09/2014 Expiry Date: 09/11/2017
Page: 1 of 2
This certificate was issued electronically and remains the property of BSI and is bound by the conditions of contract.An electronic certificate can be authenticated online.Printed copies can be validated at www.bsi-global.com/ClientDirectory or telephone +971 (4) 3364917.
Information and Contact: BSI, Kitemark Court, Davy Avenue, Knowlhill, Milton Keynes MK5 8PP. Tel: + 44 845 080 9000
BSI Assurance UK Limited, registered in England under number 7805321 at 389 Chiswick High Road, London W4 4AL, UK.
Certifications
Asbestos content The boards produced at the Knauf factory in Ras Al Khaimah have been tested on asbetos content. No asbestos could be traced in the boards’ composition. Complies with the requirements of EN 13964.
Formaldehyde content The boards produced at the Knauf factory in Ras Al Khaimah have been tested on DIN EN ISO 16009 for formaldehyde emissions. Maximum concentration levels 16µg/m3(0.016mg/m3) (complies with the requirements of EN 13964).
Environmental certifications For outstanding performances in water and energy manangement, our factory has been recently awarded the Environmental Performance Certificate from the Ministry of Environment & Water.
Quality Management System ISO 9001: 2008
Estidama Requirements
1) Manual Ceiling (ASTM) Feb-23-2017.indd 19 3/9/17 10:31 AM
1 8
Cladding of boards
Second layer cladding Second layer should be installer with staggered joints.
System’s components
Cladding of boards
Second layer cladding Second layer should be installer with staggered joints.
2)
2436
1220
1220
1220
406406406406
203
203
203
203
406 4062436 mm
1000
See Detail (J) page 08
TN Screw3.9 dia. X 25/35/45 mm Length LN Screw Hammer Fixings Wedge Anchor
ASTM Ceiling Accessories
Main "C" Channel (1.4 mm. thk.)
12
38
67
22
12.5 35 12.5
Hat Furring Channel (0.5 mm. thk.)
22
23
UD Channel (0.5 mm.thk.) L-Angle (0.5 mm.thk.)
25
35
1) Manual Ceiling (ASTM) Feb-23-2017.indd 18 3/9/17 10:31 AM
Manual Ceiling (ASTM)-UB.indd 18 3/29/17 6:25 PM
19
Regional Materials On a range of 500 miles from factory and quarry location, our boards can provide points for regional materials mentioned in different evaluation criteria (LEED, Estidama, etc.).
Total VOC content
Our boards have been tested for total Volatile Organic Compounds emissions. Detected amount: below 0.05 mg/kg.
Certificate of RegistrationQUALITY MANAGEMENT SYSTEM - ISO 9001:2008
This is to certify that: Knauf LLCPO Box 112871DubaiUnited Arab Emirates
Holds Certificate No: FM 577441
and operates a Quality Management System which complies with the requirements of ISO 9001:2008 for thefollowing scope:
The production of Metal Profiles, Plasters, Plasterboards, Ready Fix and all supporting activitieswithin the Middle East.
For and on behalf of BSI:Gary Fenton, Global Assurance Director
Originally registered: 09/11/2011 Latest Issue: 25/09/2014 Expiry Date: 09/11/2017
Page: 1 of 2
This certificate was issued electronically and remains the property of BSI and is bound by the conditions of contract.An electronic certificate can be authenticated online.Printed copies can be validated at www.bsi-global.com/ClientDirectory or telephone +971 (4) 3364917.
Information and Contact: BSI, Kitemark Court, Davy Avenue, Knowlhill, Milton Keynes MK5 8PP. Tel: + 44 845 080 9000
BSI Assurance UK Limited, registered in England under number 7805321 at 389 Chiswick High Road, London W4 4AL, UK.
Certifications
Asbestos content The boards produced at the Knauf factory in Ras Al Khaimah have been tested on asbetos content. No asbestos could be traced in the boards’ composition. Complies with the requirements of EN 13964.
Formaldehyde content The boards produced at the Knauf factory in Ras Al Khaimah have been tested on DIN EN ISO 16009 for formaldehyde emissions. Maximum concentration levels 16µg/m3(0.016mg/m3) (complies with the requirements of EN 13964).
Environmental certifications For outstanding performances in water and energy manangement, our factory has been recently awarded the Environmental Performance Certificate from the Ministry of Environment & Water.
Quality Management System ISO 9001: 2008
Estidama Requirements
1) Manual Ceiling (ASTM) Feb-23-2017.indd 19 3/9/17 10:31 AM
1 8
Cladding of boards
Second layer cladding Second layer should be installer with staggered joints.
System’s components
Cladding of boards
Second layer cladding Second layer should be installer with staggered joints.
2)
2436
1220
1220
1220
406406406406
203
203
203
203
406 4062436 mm
1000
See Detail (J) page 08
TN Screw3.9 dia. X 25/35/45 mm Length LN Screw Hammer Fixings Wedge Anchor
ASTM Ceiling Accessories
Main "C" Channel (1.4 mm. thk.)
12
38
67
22
12.5 35 12.5
Hat Furring Channel (0.5 mm. thk.)
22
23
UD Channel (0.5 mm.thk.) L-Angle (0.5 mm.thk.)
25
35
1) Manual Ceiling (ASTM) Feb-23-2017.indd 18 3/9/17 10:31 AM
Manual Ceiling (ASTM)-UB.indd 19 3/29/17 6:25 PM
info@knauf.ae
Fax: +971 4 334 9659
Phone: +971 4 337 7170
Knauf Head Office
www.Knauf.ae
Knauf Gypsum India Pvt.LtdKnauf Manufacturing Plant
No. 8 - C, 8th Floor Commercial ComplexDoshi Tower, New No. 205, (Old No.156)Poonamallee High Road, Kilpauk Chennai - 600010 Tamil Nadu, IndiaTel: +91 44 49580000Fax: +91 44 49575300
P.O.Box 50006Ras Al Khaimah, U.A.E.Tel: +971 7 268 9837Fax: +971 7 221 5301
Disclaimer:
The information provided in this leaflet is only intended to give guidance in selecting and using Knauf products. While we make every effort to ensure its accuracy, neither Knauf LLC and its branches nor any of tis employees or affiliates warrant or assume any legal liability or responsibility for the completeness or usefullness of any failure in installation or constructing any structure installation or building or caused by using this leaflet. Readers are adviced to independently verify this information prior to rely on it. In particular, readers must obtain appropriate independent advice on the use in specific structures, insllations or buildings to ensure compliance with all regulations, including health and safety regulations. Knauf reserves the right to amend technical specification.
The constructional and structural properties, and characteristic building physics Knauf system can solely beensured with the exclusive use Knauf system components, or other product expressly recommended by Knauf.
P.O.Box: 112871, Dubai
top related