TRANSCRIPT

Halfen Fixings

Association for Structural Engineers of London Boroughs

HALFEN FIXINGS

23rd October 2015

Mark Smith

Technical Director

Halfen Fixings

� Halfen today

Halfen, a brief introduction

Global Presence

4 plants in Europe

24 sales offices

Global sales

sales within over 50 countries

Global cultureover 1200 employees in 35 countries

Halfen Fixings

Market leader for fixing and reinforcement

systems

Innovative and competitive solutions

Highest levels of quality and safety

Halfen, a brief introduction

Halfen Channel

Cast-in channels

Halfen Channel

Tolerance

Adjustability

Halfen Channel

Nail holes

Installation

Halfen Channel

Halfen Pourstop

Standard Lengths are 3000mm Cut to Length

on Site.

Halfen Pourstop Detail

Halfen Channel

Special corner detail

Waterman Place, London

Halfen Ski Detail

Halfen Channel

• No risk of damaging concrete due to

hammer drilling• No damage to reinforcement

• No problems with oversized or shallow

holes

• No dust or noise from drilling• No waiting for chemical anchor resin to

harden

• No need for power supply

• Very fast and easy to install• Can be cast in close to concrete edges

• Multiple fixings possible at close spacing

• Reduced installation time for subsequent fixings

Advantages of cast-in channels

Halfen Channel

Software

www.halfen.co.uk

Halfen HZA channel

Toothed channels

Toothed

lips

Long welded

I-anchors

Hot rolled

channel

Halfen channel – Exhibition Hall

Halfen façade fixings

HK4Brick support

& SUK Stone support

Halfen HK4 brick support

Halfen HK4 brick support

Thermal values

Chi values

These can be used to calculate the

exact effect of the HK4 support brackets

on the heat transmission coefficient of the wall

SUK – St James Gateway

Halfen Reinforcement

HDBpunching shear

reinforcement

HBS & HBM

Reinforcement couplers

SBCBalcony connnectors

HIT

Thermal connections

CRET

Shear connectors

Halfen HDB punching shear

Why do you need punching shear reinforcement ?

Halfen HDB punching shear

• Faster to install than links

• Easy visual inspection

Halfen HDB punching shear

CE Marked

European Technical Approval with

designs based on EC2 codeSoftware

HDB

Punching Shear Reinforcement

www.halfen.co.uk

Halfen HBS Couplers

It is easy to check the completed

connection for correct safe fitting

Can be fitted without torque wrench

Due to its slender shape increased

concrete cover and reduced

congestion

CARES approvals for normal

construction and Sellafield nuclear

approval

HBS-05 Reinforcement Coupler System

Halfen HBM Couplers

CRET Shear System

More efficient shear load transfer across

the movement joint than a simple dowel

Vertical anchor rods and support box

activate the maximum amount of the

slab

Fewer columns are required

More floor space gained

CRET

for longitudinal movement onlyCRET-V

for longitudinal and lateral movement

CRET Shear System

CRET Shear

Dowel Connector

Halfen Balcony Connections

Steel Balcony Connector

SBC

Halfen Balcony Connections

SBC

• SBC cast-in assembly

easily fixed to shutter

• Avoids complicated

modifications to

shuttering

Halfen Balcony Connections

SBC

• The thermal separator

minimizes the cold bridging

Halfen Balcony Connections

SBC

• The bracket gives horizontal

and vertical adjustment

• Bracket can be bolted, the

façade can be completed

and the balconies bolted on

at a later date if required

HIT-HP : the next generation

Halfen Balcony Connections

Halfen HIT

Insulation requirements

F120

dB

Thermal

insulation

Fire protection

Sound insulation

ψψψψ

� Thermally separated connections with Halfen balcony elements

Halfen HIT

Mineral wool as insulation against fire and low

temperature

Reinforcment

Stainless steel

Product overview

Casing made of plastic material Compression shear bearing

(CSB) made of ultra-high strength

fibre-reinforced mortar

Flash-butt-welded tension

HIT-HP/SP MV

Halfen HIT

Advantages

� approval

� Load capacity

� Fire protection and Impact sound

MRd to 58,6 kNm/m

for h = 16 cm

Halfen HIT

Testing and FE modelling for CE – HIT-HP/SP

More than 80 FE-calculations:

� practical constructions (M 1:1)

� compression shear bearings (CSB)

More than 40 Full-scale tests:

� load capacity

� fire tests

� load capacity after the fire test

� Impact sound tests

Material tests:

� > 1000 compression tests

� > 800 bending test

� …..

Halfen HIT

Advantages

� Thermal protection

Halfen HIT

TIQ

S7 & S8

Stratford, London

Engineers : Buro Happold

Structural engineers: Walsh

Precaster : Grants Precast

Developer : Lend Lease & LCR

Architect:

Rogers Stirk Harbour & Partners

Residential Architects :

Allies & Morrison

Halfen HIT

TIQ

Halfen Channel

TIQ

Halfen HIT

Halfen HIT

Halfen

Summary

� Halfen channel offers site adjustability

� Software available to download

� Extensive range of HIT thermal products to

provide solutions for cold bridging problems.

� Technical support available on all Halfen’s

products