hawker 750/800/850/900 series cabin window shades
Post on 18-Feb-2022
9 Views
Preview:
TRANSCRIPT
620 NW 35th Street, Boca Raton, Florida 33431 USA | Tel: +1.561.244.7400 | Fax: +1.561.735.3384 | www.atgshades.com
B
B
AA
POWERCONNECTION
MOUNTINGTAB
SWITCH
OVERLAYPANELAPERTURE
402.515.85
362.214.26
SECTION A-A
57622.76
271.06
738.5R29.08
INBOARDLENS
48.61.91
51.32.02
SECTION B-B
MOTORBARS
OUTBOARDLENS
HAWKER 750/800/850/900 SERIESCabin Window Shades
SPC-MKT-82-001_A
NOTE: ALL DIMENSIONS IN [MM] INCH
ATG82F001
ATG RELEASED
620 NW 35th Street, Boca Raton, Florida 33431 USA | Tel: +1.561.244.7400 | Fax: +1.561.735.3384 | www.atgshades.com
B
B
AA
POWERCONNECTION
MOUNTINGTAB
SWITCH
OVERLAYPANELAPERTURE
402.515.85
362.214.26
SECTION A-A
57622.76
271.06
738.5R29.08
INBOARDLENS
48.61.91
51.32.02
SECTION B-B
MOTORBARS
OUTBOARDLENS
FEATURESWindow shade assemblies are enclosed, self-contained, electrically
powered units consisting of:
•Dualhoneycombpleatedshadeandrailsystem:
- Translucent shade providing light diffusion
- Opaque (blackout) shade
•Rackandpinionguidancemechanism
•28-voltdcmicro-miniaturecustommotors
• Printedcircuitboardcontrollerwithsoftwarecontrolcabin
management system
•Abilitytointegratewithanyswitch/CMSsupplier
•Ultrathin,approximately1”overalldepth
• State-of-the-art,lightweight,polycarbonateconstruction
•Weight:approximately6lb(2.7kg)
• Availablein12standardcolors.Customcolorsavailableat
additional cost and leadtime
For reference only. Please contact Aerospace Technologies Group, Inc. for the most current information.
HAWKER 750/800/850/900 SERIESCabin Window Shades
Wiring Pin-Out Description for Aircraft Interface Connector:
Aircraft Interface ConnectorMolexP/N:39-01-2080
Pin 1 - 28 VdcPin 2 - Attendant OpenPin3-GroundReturnPin4-RemoteUserOpenPin5-N/CPin6-AttendantClosePin7-N/CPin8-RemoteUserClose
1 5
2 6
3 7
4 8
SUPPORTATAformat100CMM/IPCshippedwitheach
order
AOG spares availability
5-year warranty
CERTIFICATIONMeetsRTCADO-160E/F/G
Meets14CFR25.853requirementsfor
flammability
FAA PMA
ELECTRICALNominal Operating Voltage: 28 Vdc
EmergencyOperation: 18Vdc-32.5Vdc
SystemIdleCurrent: 35mA
Nominal Operating Current: < 120 mA
MaximumInrushCurrent: 405mA(<20msecs)
LockedMotorCurrent: 272mA(<25secs)
ATG RELEASED