7/28/2019 Helling Engl KATALOG
1/42
Testing
Geschichte von Helling
27 August 2007
Non destructive
testing
-
7/28/2019 Helling Engl KATALOG
2/42
2
Dear reader!
Herewith I would like to introduce you to the company
HELLING. The catalogue will give you an insight intoour delivery program concerning equipment, products
and accessories for Non Destructive Testing.
HELLING company was founded in 1863 and has long
experience concerning the European market. Constant
growth and partnership have been contributing to
consequent development of the company and today
HELLING is a leading manufacturer and supplier for
high quality equipment and products for Non
Destructive Testing in more then 39 countries.HELLING company is a member of German
Association for Non Destructive Testing (DGZfP) and also of Russian Association of Non
Destructive Testing & engineering diagnostics, Czech association of Non Destructive
Testing, Japan and American Associations.
Based on well-developed scientific foundation we design and offer unique testing techniques,
corresponding to world standards requirements.
We hope for long and beneficial co-operation,
Yours faithfully,
President of HELLING
N. Riess
-
7/28/2019 Helling Engl KATALOG
3/42
3
HELLING GmbH Spkerdamm 2 D-25436 Heidgraben (bei Hamburg) Postfach 2132 D-25437 TorneschTelephone: +49(0)4122 922-0 Telefax: +49(0)4122 922-201 e-mail: info@hellinggmbh.de www.hellinggmbh.de
Contents
Penetrant testing
Dye penetrant method (red-white) 4Fluorescent method 6
Penetrant testing systems 7
Test panels 8
Magnetic particle testing
Magnetizing devices 11
Stationary test facilities 13
Demagnetizations 13
Colored magnetic particles 14
Fluorescent magnetic particles 15
Additional products 16Reference blocks 18
Black light
Stationary UV lamps 20
Portable UV lamps 21
UV-LED-sources 22
Leak testing
Bubble method 23
Hydrogen leak detector 24
Helium leak detector 24
Ultrasonic leak detector 25
Fluorescent concentrate 26
Radiographic testing
Radiographic films 27
Developing machines 29
Accessories 30
Ultrasonic testing
Ultrasonic thickness gauge 31
Ultrasonic test facilities 31
Accessories 32
Auxiliary equipment for weld
inspection 33
Temperature detection 35
Delivery program 40
-
7/28/2019 Helling Engl KATALOG
4/42
4
Penetrant testing (PT), how it works
The penetrant method of non-destructive testing is based on capillary penetration of indicator
liquid (penetrant) into the surface defects (cracks, pores etc.). After intermediate cleaning and
subsequent drying, a developer is applied as a thin, white layer onto the surface to be
inspected. The developer pulls the penetrant out of the surface defects and makes themvisible as coloured, linear or rounded indications. Documentation is possible by means of
adhersive foil, photographic or video techniques.
Procedure of penetrant inspection.
Precleaning
Mechanically, with brush By stream process Degreasing with hot steam Cleaning with solvent
Predrying
Application ofpenetrant.
Dip in bath Laying with brush Application by spraying Application by electrostatic mean
Intermediate
cleaning
With lint free cloth, water-moistened or a
spongeWith water-moistened brush Rinse with water With lint free cloth or sponge,
moistened with a special solvent
Drying
Dry in open air Wipe with a lint free cloth Blow with dry, clean air Dry with warm air
Application of
developer
By immersion(aqueous developer) Application from the diffuser /aerosol (non-aqueous developer)
Electrostatic application(non-
aqueous developer)
Application of dry powder developer(
in special cases, e.g. extremely porous
surfaces)
Examination of the
surface and
documentation
Viewing under day light or in artificial
illumination min.. 500 Lux (EN 571-1/EN
3059)
If using fluorescent penetrant:
Ambient illumination: < 20 Lux
Intensity of UV: 1000W/cm2
Documentation by adhasive foil Photo-optical documentation Documentation by means of videofilming or photocamera
Penetrant testing systems
Met-L-Chek, Standard Chek, Nord-Testare reliable in detecting the defects with awidth down to the range ofm.
Necessary condition: defects must be opento surface.Systems are also used for the leak testing.
The examination of testing
media adequacy is done inaccordance with :
AMS 2644
AMS 2647
DIN EN ISO 3452-2 (3)
ASME
Penetrant inspection can accurately and
easily detect surface defects independent oftypes, materials and surface configurations ofthe objects to be tested. Other methods of
non destructive testing, can only be appliedfor these requirements with restrictions.
-
7/28/2019 Helling Engl KATALOG
5/42
5
Products are available in aerosol tanks (400 and 500 ml), containers(1; 10 l) and barrels (200 l).
Contrast (red-white) method
Areas of us e:
Aircrafts industry, Metallurgy, nuclear industry, Electrical engineering, Engineering, Foundry, Blanking, Shipbuilding, Medicine,Car production.
Work with materials:Alloyed and plain steel, cast iron, platings, plastics*, welds, nonferrous metals, products of powder metallurgy, steatite,ceramics*, other synthetic materials.
*check for adequacy
MET-L-Chek, Standard-Chek & Nord-Test*
Used in temperature ranges from -5 to + 50. In low temperatures (from -5 to + 10 ) it is necessary to increase time ofpenetrating. One must take into account peculiar specifications according to DIN EN ISO 3452 part 2 & EN 571 part 1. Forexamination in higher temperatures (from +10 to + 175) Super-Chek was especially developed..
MET-L-Chek, checked and approved
DIN EN ISO 3452-2, EN 571, KWU correspond to requirements: Lloyd's Register of Shipping, Bureau Veritas, Bureau CentralHollandais, Germanischer Lloyd, MIL-I-25135/QPL-25135, AMS 2644, ASME Boiler and Pressure Vessel, ASTM E-165,
ASTM-E1417, certificated NAVSEA 250-1500-1, RDT & EdF, RCC-
Standard- Chek & Nord-Test examined and approved according to: DIN EN ISO 3452-2, EN 571, KWU correspond to requirements Lloyd's Register of Shipping, Bureau Veritas, Bureau CentralHollandais, Germanischer Lloyd, MIL-I-25135/QPL-25135, AMS 2644, ASME Boiler and Pressure Vessel, ASTM E-165,
ASTM-E1417.Content of sulfur is determined according to ASTM D 516-88, examination of the content of halogens (fluorine and chlorine) isdetermined in accordance with ASTM E 165-91, application 2, method A and ASTM E 165-91, application 3.
Example of Nord-Test penetrant system
Remover U87 Penetrant U88 Penetrant Red 3000 Developer U89 Environmentally
safe remover on
a solvent base.
Fumes fast.
Doesnt leavedints.
High sensitivity
Easily cleansed with water
Smells slightly
Sensitivity according to:DIN EN ISO 3452-2II-level (high sensitive)
Ultra high level of sensitivity
Water washable
Doesnt contain AZO-colouring agents
Smells slightly
Testing by luminescent method, by means of
ultraviolet illumination is possible
Sensitivity according to:DIN EN ISO 3452-2 II-level (high sensitive)
Fine-grained whitepowder on a spirit
base ,
Doesnt containaroma additives.
1 2 3
Indication of cracks on standard panel1
(max width of cracks 1,5 m, depth 28,5 m) by use of
NORD-TEST (U87, Rot 3000, U89)system under following
viewing conditions:
1.At day light (500 Lux)
2.At day light (500 Lux) +ultraviolet(1000 W/cm2) illumination
3.At ultraviolet illumination (5 Lux, 1000 W/cm2)
-
7/28/2019 Helling Engl KATALOG
6/42
6 Available in cans(1; 10 l) and barrels (200 l).
Develo
per
RemoverEmulsifier
Penetrant
Fluorescent method**
Fluorescent penetrants according to AMS-2644 & ASTM E-1417
REMOVAL METHODS:A Water washable
B Post emulsifiable, lipophilic emulsifier.
C Solvent wipe removal
D Post emulsifiable ,hydrophilic emulsifier
(17-20%: dip or < 5%: spray, concentrations).SENSITIVITY LEVEL:1/2 very low; 1 low; 2 medium; 3 high; 4- very highDEVELOPER FORMS: a Dry developer; Use with all the fluorescent penetrants(Type I), Methods A, B, C & D.
b Water soluble type; Use with fluorescent penetrants (Type I), Methods B, C & D.
c Water suspendable developer ; Use with all the penetrants , Methods A, B, C & D.
d Nonaqueous developer; use with (Type I) penetrants , Methods A, B, C & D.
e - Nonaqueous developer; use with (Type II) penetrants, Methods A, B, C & D.
f Special application material.
SOLVENT CLASS: 1 Halogenated solvent remover, use with all penetrants, Method C.
2 Nonhalogenated solvent remover, use with all penetrants, Method C.
3 Special application material used with special application penetrants, Method C.
Name TypeMethodClass/
form
Sensitivitylevel
AMS-2644
QPL4
General description
FP-900 I A & C 1/2 YES Very low sensitivity, general metal working
FP-901 I A & C 1 YES Low sensitivity, general metal working
FBP-911 I A & C 1 YES Low sensitivity, oil and solvent free
FP-921 I A & C 1 YES Low sensitivity, aerospace applications
FP-902 I A & C 2 YES Medium sensitivity, general metal working
FBP-912 I A & C 2 YES Medium sensitivity, oil and solvent free
FP-922 I A & C 2 YES Medium sensitivity, aerospace applications
FP-903 I A & C 3 YES High sensitivity, all applications
FBP-913 I A & C 3 YES High sensitivity, oil and solvent free
FB-923 I A & C 3 YES High sensitivity, aerospace applications
FBP-914 I A & C 4 YES Ultra High sensitivity, oil & solvent free
FP-93A(M) I B, C & D 2 YES Medium sensitivity, all applications
FP-95A(M) I B, C & D 3 YES High sensitivity, all applications
FP-97A(M) I B, C & D 4 YES Ultra high sensitivity, all applications
E-57 I B NA YES Lipophilic emulsifier forFP-93/95/97A(M)
E-58D I D NA YES Hydrophilic emulsifier forFP-93/95/97A(M)
E-59 I & II C, class 2 NA YES Solvent remover for all penetrants
E-59A I & II C, class 2 NA YES Solvent cleaner / remover for all penetrants
R-502* II C, class 3 NA NA Special high temperature remover
D-70 I & II Forms d & e NA YES Nonaqueous developer, all penetrants
D-72A I Form a NA YES Dry powder developer, all Type I penetrants
D-76B I Form b NA YES Aqueous soluble developer
D-78B I & II Form c NA YES Aqueous suspendable developer
D-702* II Form f NA NA Special high temperature developer
Met-L-Chek
-
7/28/2019 Helling Engl KATALOG
7/42
7
Procedure of fluorescent penetrant inspection
System of the fluorescent penetrant testing
Present system correspond to requirements of world standards: MIL-I 25135E, MIL STD 6866, AMS 2644, EN 571-1. Allcomponents meet the European requirements on Health, Safety and Ergonomics. The inspection system is basically made ofstainless steel and equipped with first class means for functional control, delivered by producers like Siemens, Rittal,Weidmller, Festo, Sick, Balluf.
Basic phases of processing:
1. precleaning
2. wash3. dry to =1000C4. cooling to 400
5. immersion in a tank with penetrant6. water wash
7. immersion in a tank with emulsifier8. post water wash
9. dry in heater=600
C10. electrostatic application of powder developer11. inspection of the sample in a cabin at ultraviolet illumination
Precleaning
Drain
Penetration
Emulsification
Water wash
Wet development
Hot air dry
Inspection(20Lux; 1000W/cm2)
Hot air dry
Dry development Fast drying
development
Water removal Penetrant removal
-
7/28/2019 Helling Engl KATALOG
8/42
8
Test panelsSensitivity of inspection media, quality of intermediate cleaning and control of the whole penetrant
process are determined on reference blocks, i.e. on metal panels with defined roughness and provided
with standardized artificial cracks(defects).
Test panel ASME V
Used for the testing of the penetrants indication sensitivity. Due to thedivision of the test panel into two parts, it is possible to compare 2 differentpenetrants.Present test panel is an aluminium plate (805010 mm), divided by a notch(5021,5 mm), into two parts. Because of a special thermal treatment
ASME panel, there is a uniform crack pattern, which is visible on both sidesof the test panel.
Indication of cracks by using of system
NORD-TEST (U87, Rot 3000, U89)
Test body 2 (EN ISO 3452-3)
The reference block 2 consists of an austenitic base plate, which is chromium-
plated on one side and provided with 4 different surface roughnesses on the otherside. 5 star-shaped crack patterns of different sizes are generated in the chromium-
plated side by applying a pressure load to the rear side with a ball. The rough areas
are used for control of the intermediate rinse step. The indication on the referenceblock gives no suggestion of the indication on the part under test. The user uses the
reference block for the control of inspection material. For checking the rinsability
of penetrants four adjacent areas sized 25 x 35 mm are placed on one half of thepanel with roughness of Ra = 2,5 m, Ra = 5 m, Ra = 10 m and Ra = 15 m. The
defect area is located on the other half of the test surface of the panel. The size ofeach defect is determined optically at its maximum diameter using calibrated scales
Reference block1 (EN ISO 3452-3)
The type 1 reference block consists of a set of 4 nickel-chrome plated panels with10, 20, 30 and 50 m thickness of plating respectively.
The 10, 20 and 30 m panels are used for determination of the sensitivity of
fluorescent penetrant systems.The sensitivity of colour contrast penetrant systems is determined by using the 30
and 50 m panels.
The type 1 panels are rectangular in shape with typical dimensions of 35 x 100 x 2mm Transverse cracks are made in each panel by stretching the panels in the
longitudinal direction. The width to depth ratio of each crack should be
approximately 1:20.
A declaration stating conformance to EN ISO 3452-3 and in line with EN 10204,
Type 3.1 B shall accompany each test block.
Test body JIS Z 2343
Used to determine the sensitivity of penetrant systems and for comparingtwo penetrants, one of which can be taken for standard. Consists of two testpanels which are bronze planes 100352 mm , covered with NiCr-layer. InNiCr-blanket. Crosscut cracks are made, depth of which fits the width of theNiCr-blanket. (Designed in 4 types 10, 20, 30 & 50 m). The quotient ofcracks width to their depth equals 1:20. Each test-panel has a certificateaccording to EN 10204, type 3.1 B, which verifies its aptitude to EN ISO3452-3. Test-panels with cracks width of 10 m, 20 m, 30 m used for afluorescent sensitivity testing penetrant systems. The sensitivity of contrastpenetrant systems is determined by means of panels, depth of cracks inwhich - 30 and 50 m.
Article No. 127.100.000
Article No. 127.550.000
Article No. 127.400.001
Article No. 127.600.001 - 10 mArticle No. 127.600.002 - 20 mArticle No. 127.600.003 - 30 mArticle No. 127.600.004 - 50 m
-
7/28/2019 Helling Engl KATALOG
9/42
9
Article No. 127.700.004 Article No. 127.700.003
Article No. 127.700.002 WTP-2
Test panel WTP-1 & WTP-2Designed to evaluate removability of the fluorescent penetrant. PanelWTP-2 is a stainless steel panel, measuring 46 inches and 0,090 thickwith two parallel medium rough strips, each 61,5 inches, separatedby a smooth 1 inch strip. The panel is used to evaluate the quality ofremovability according to the requirements of MIL-STD-6866 & ASTM E-1417.
Test panel PSM-5Present test panel is used for testing the penetrant process in whole.Test-panel PSM-5 is rectangular,1015cm, width 2,3mm, made fromstainless steel.The chromium-plated strip on the side contains 5 crack patterns. Theraised, circular or star-shaped crack patterns are arranged according to
their sizes.The biggest defect becomes visual after low-sensitive penetrant`streatment. The smallest defect can hardly be seen even after application ofhighly sensitive penetrants. There are no two identical panels. The crackpattern differs from one panel to another. Test panel is designed in twomodels. Both models are designed in accordance with specification Pratt-Whitney P/N TAM 146040. The panel is not to be used for detecting thesensitivity of penetrants system.
Indication of cracks by use of FP903 & D70
KDS-Test panelTwin KDS Panel, with the cracked sections side by side, facilitate quick andaccurate determination of relative defect visibility.Twin KDS Panel, with the grit blasted sections side by side, makefluorescent background comparison simple.Twin KDS Panel comes in two models.Model WW for use with Method A water washable penetrants. Model PE foruse with Method B,C,D nonwater-washable penetrants.The difference between two models is in crack size. Model WW cracks rangefrom 1/22 1/6 inches while Model PE cracks range from 1/64 to1/11inches.
Twin KDS PE Twin KDS WW
Comparator UTE-3
Designed for right determination of ultraviolet radiation intensity at workplaceif using fluorescent penetrants.Used to compare size of pores and comparison board of optical probes withtext according to Jger 1 andJger 2.
Article No. 127.700.001 WTP - 1
Article No. 127.800.000
Article No. 127.850.000
-
7/28/2019 Helling Engl KATALOG
10/42
10
Magnetic particle testing
The magnetic particle testing method (MT) is one of the most sensitive, reliable and productive NDT-method forsurface inspection of products from ferro-magnetic materials. The method is based on the attraction of ferro-magnetic particles by force of leakage flux like cracks, laps, leak of fusion, pores which appear above surfacedefects after adequate magnetization. MT can be used for surface defects (open to the surface) and under certain
conditions for detection of near-surface defects. Higher probability of detection is given, when the direction of adefect is perpendicular to the direction of the applied magnetic field. The smaller the angle between defect andfield direction the weaker the indication
Microscope imaging of cracks Cracks indication by fluorescentT method
Magnetic Particle testing is used in almost every industry branch:metallurgy, machine building, aircraft building, shipbuilding, during production in steelworks, at pipe
installation), electric power and chemical machine building, Means of transportation (aircrafts, rail cars,vehicles).Magnetic Particle testing procedure consists of the following: 1 Preparation of the items` surfaces of the testobjects for testing, 2 magnetization of the object, 3 application of magnetic particle suspension onto the testobject 4 Testing of the object, 5 demagnetization.
Circular, longitudinal and combined magnetization are used for MT. There are a lot of magnetization schemes,some of which are shown below.
Circular Longitudinal
Magnetic field direction10m
-
7/28/2019 Helling Engl KATALOG
11/42
11
Article No.131.002.000
Hand magnetizing devices.
Specifications:
UM8 UM8/42*
UM15 UM15/42*KMU
8/42*
Permanent
magnetFlaw Finder
Article No. 131.002.001 132.002.000 131.010.000 131.010.001 131.015.100 131.001.010
Distance between poles (mm) 168 168 76-260 76-260 195 to 250
Pole cross section (mm) 27,5x22,5 27,5x22,5 27,5x22,5 27,5x22,5 27x27
32Dimensions LHmax (mm) 235x156 235x156 230x132-200 230x132-200 195x320 150 50
Tangential field strength
A/cm (DIN 54131-2)40 36 23 21 35 23
Standard length of the cable(m)
3 3 3 3 3
Supply voltage, V 230 42 230 42 2x42
Protection system IP65 IP65 IP65 IP65 IP65
Pull-off strength app.:EN ISO 9934-3:2002
17 kg 16 kg 7,5 kg 7,5 kg 16 kg 30 kg
Weight (kg) 3,4 3,4 3,8 3,8 11,0 1,0
*Additional transformer 230/42 V is necessary
UM8UM15
KMU 8/42 Flaw Finder
Article No.131.002.001Article No.131.010.000
Article No.131.001.010
-
7/28/2019 Helling Engl KATALOG
12/42
12
Portable magnetizing devices
Specifications:
DIN 54131 & VDE Hellotest 10 Hellotest 20 Hellotest 40 Hellotest 60Article No. 131.020.100 131.020.300 131.050.005
Alternate currentMax. test current, measured via highcurrent 5 m cable.
Effective value A 1000 2000 2800 4200
Peak value A 1400 2800 4000 6000
Short-circuit A 3700 6900 8000 9000
Infinitely variable Main
Operating data
Source voltage V 230 400 400 400
Frequency Hz 50 50 50 50
Power input max. kVA 3 12 23 50
Open circuit voltage max. V 3,2 6 7,5 10,5
Control voltage V 15 15 15 15
Dimensions
Length mm 325 445 500 1200
Width mm 290 290630 630
Height mm 385 385 965 910
Weight kg 17 30 105 160
-
7/28/2019 Helling Engl KATALOG
13/42
13
Stationary Magnetic Devices
Defectoscopes are designed and constructed due to client`s performance specification. As an example you cansee these two the most popular defectoscopes.
Demagnetizing devices
HETT 150/250/350/450/550
900-Universal WE II
Basic device for combined magnetization of items byalternate current.
Test detail length 900 mm
Test detail diameter 450 mm
Test detail mass 450 kgCircular magnetization current 2800 Longitudinal magnetization current 15000 tPower consumption 55 kVA
Air-operated clamp lead 7 mmSource voltage 3400 VLength 2200 mmHeight 2300 mmWidth 760 mmWeight 780 kg
ZER-O-MAT
Noncontact magnetization of the test objects. A specially designedU-like solenoid lets detect surface defects every direction oncylinder-like objects.
Demagnetization coils are designed for reducing the remanent magnetism of objects, magnetized duringpreceding MT.
150 250 350 450 550Magnetic field strength /cm 110 90 80 65 54
demagnetization window, mm 150 250 350 450 550
-
7/28/2019 Helling Engl KATALOG
14/42
14
Coloured magnetic particles
For preparing a suspension on a water & oil base
Item Colour
Average
dimension
of the
grain (m)
Recommended
concentration (g)
Sedimentation
( 2 g/l)/100ml
BW333
black 4 3-5 0,1
WD105 grey-white 37 5 0,1
TGL
orangeorange 47 5 0,3
TGL11 brown 35 5 0,3
WW50 grey-white 30 5 0,25
TGL12 green 35 5 0,3
magnification:
140
175
175
175
175
630
.
Grain form Indication of artificial cracks on a
test body 1
*Wetting-, antifoam-, antirust-agentBC502 (30ml./1l.) isnecessary to prepare a suspension on a water base.
Article No. 135.001.520
Article No. 135.003.030
Article No. 135.001.510
Article No. 135.001.511
Article No. 135.001.530
Article No. 135.002.010
-
7/28/2019 Helling Engl KATALOG
15/42
15
Fluorescent magnetic particles
Delivery:
1. Dry powders in 1kg container2. Concentrates (1:20, 1:50) on water base (cans 1; 10 l)3. Ready-to-use suspensions on oil base
magnification:
280
280
630
630
630
ItemFluorescence
coefficient
Gd/W
Average
grain size
(m)
Recommended
concentration (g)
Sedimentation
( 1 g/l)/100ml
MEF
8-TC1,7 2 0,6-1 0,15
LY
25002,8 4 0,4-1 0,3
LY
23003,4 6 0,4-1 0,25
LY
1500 5,2 12,5 0,6-1,5 0,2
CGY
400011,3 14 0,5-1,5 0,25
Article No. 135.001.008
Article No. 135.001.040
Article No. 135.001.150
Article No. 135.001.010
Article No. 135.001.180
-
7/28/2019 Helling Engl KATALOG
16/42
16
Magnetic particle testing by means of aerosol system from the firm HELLING
quick and efficient handy and easy to use reliable estimation of defects high sensitivity
economic material consumption in accordance with ASME Code, Sect. V,
ASTM E 709:95, EN ISO 9934 doesnt contain CKW/FCKW
NRF 101Article No. 135.005.050
Luminescent magnetic suspension of ultra high sensitivity. Average grain dimension4 m. Form is ready for use. High-flash magnetic particle suspension in a slightlysmelling oil-carrier-fluid. It is a good corrosion inhibitor.
NR 104A
Article No. 135.006.020
White background paint. White pigmented suspension in a slightly volitilizablesolvent, doesnt contain chlorinated hydrocarbons. To be applied as thin layer with athickness up to 30 m.
NRS 103
Article No. 135.005.070
Black magnetic suspension of high sensitivity . Average grain dimension of 4 mHigh -flash magnetic particles suspension in a slightly smelling oil-carrier-fluid. It isa good corrosion inhibitor.
NR 107Article No. 135.006.050
Remover for background paint.
Additional products
Oil carrier fluid for preparing magnetic particle suspensions.
Specifications: Oil 4000
Inspection method Oil 4000
Density DIN 51 757 762
Kinematic viscosity in 20mm
2/s
Kinematic viscosity in 40mm
2/s
Kinematic viscosity in 50mm
2/s
DIN 51 562DIN 51 562DIN 51 562
2,01,61,4
Burning point DIN 51 758 >60
Chilling point DIN ISO 3016
-
7/28/2019 Helling Engl KATALOG
17/42
17
Magnetic field strengthmeter MP-U, MPU-ST
Present device is designed for measuring the magnetic field strength (AC, DC) in range of 0 2 000 /m.
Liquid-crystal 3.5 digit display, indication of battery condition. The following probes are available: axial field
probe ( 6,0 mm); tangential field probe ( 1,6 mm); flexible sensor( 0,7 mm).
Bulb for sedimentation control Hydraulic pump atomizer
PROFI
Specifications: MP-U MPU-ST
Measuring range0-200 /cm;
0-2000 /cm
0-200/cm;
0-2000 /cm
0-20000 /cm
Unit measure /cm; Oe
Indication Liquid-crystal 3.5 discharge display
Error 2%
Power supply 9 V (ICE 6 LF 22)
Memory2000
measurements
Interface device RS 232 (V.24)
Dimensions, mm 1608027
Weight, g 250
Designed to detect suspension quality. Determines themagnetic powder concentration in suspension.Corresponds to standards: ASME V, ASTM E 709,1444
Used for magnetic powder sputtering suspensions, andalso for colored and fluorescent penetrants. Operatingpressure 4 bar, container volume 1,5 l, max. filling volume1,3 l.
Article No. 133.005.010
Article No. 126.400.000Article No. 134.005.000
-
7/28/2019 Helling Engl KATALOG
18/42
18
Reference Blocks/Field Indicators
Magnetic field direction
Magnetic field direction
Reference block 2 (EN ISO 9934-2)Reference block is a self contained unit requiring no external magnetic fieldinduction. Used to determine the quality of the magnetic particlesuspensions. The block consists of 2 soft iron bars, separated by a thin(15m) Al-foil, representing an artificial defect. Permanent magnets are seton the sample ends. Because of the permanent magnetic field the bars getmagnetized and magnetic particles accumulate over the artificial defect,forming indicator lines. The quality of the suspension or dry powder isestimated over the summarized the length of the lines.
Specifications:Dimensions (LWH): 1554012 mmTangential component of magnetic fieldover the artificial defect at points G (-4): -1/m
(4): 1/cm
Reference block 1 (EN ISO 9934-2)The reference block is a disc with 2 types of natural cracks on the surface.Coarse cracks are the result of the polishing, fine cracks are the result ofstress corrosion. The block is permanently magnetized by centralconductor through the hole. Estimation of magnetic particle suspensions ismade by visual or other appropriated method of comparison of theindications.
Specifications:Sample diameter: 50 mmSample height: 10 mmThe width of cracks: 2-10 m
Field Indicator according to BertholdDesigned to determine the strength and direction of the selectedmagnetizing setup and the quality of magnetic powder suspension.
Specifications:Sample diameter: 20 mmSample height: 5 mmHolder length: 95 mmWeight: 24 g.
Magnetic Field Indicator D 250 (ASME-V)The magnetic field indicator type D 250 is designed in accordance with thefollowing specification methods of non destructive testing :MIL-STD-271 E, 4.3.2.5.5, figure 8NAVSHIPS 250-1500-1, 12.4.1.5, figure 12 17
ASME, section V, Art. 25, SA-275, figure 8The sample is used for localization of magnetic fields and their directionsduring performance of magnetic particle testing.
Specifications:Sample diameter: 27 mmSample height: 4 mmHolder length: 100 mmWeight: 42 g.
Ketos Ring (ASTM E 1444-01)The sample is designed to determine the defectoscope working capacityand the quality of magnetic powder suspension. The sample representsitself a 7/8"(22,2mm)-wide disk. Outer diameter 5"(127mm), inner diameter1,25"(31,75mm) - made from steel AISI 01.12 holes (diameter 0,07" (1,78mm) are placed on different distances fromthe outer cylindrical surface. When current (FWDC or HWDC) is passedthrough the central conductor, (conductor diameter 1 3/16 , conductor
length mustnt be less then 400mm), waste fields appear, decreasing asthe distance from the hole to the outer cylindrical surface increases. Whenthe magnetic suspension is applied on the disk, magnetic powderaccumulates over the cylindrical surface holes, forming indicator lines.The process, corresponding to the recovery of the majority of lines isaccepted as optimal.
Article No. 134.002.100
Article No. 134.002.002
Article No. 134.003.000
Article No. 134.003.100
Article No. 134.004.000
-
7/28/2019 Helling Engl KATALOG
19/42
19
Roughness standard test block enclosed
Hardness standard test block enclosed
Test-kit E 100 forTConsists of accessories, necessary for the MP:
Magnetic field strength meter MPU
UV-intensity measuring device Reference block 1
Reference block 2
Package of detectors Burmah-Castrol TypeI or TypeII
Field Indicator according to Berthold
Bulb for sedimentation control
Gelatine film for documentation (10 documentation cards)
Surface Roughness TesterTR100Determination of surface roughness quickly and qualitatively (Ra;Rz)
Specifications: Tracing length: 6 mm
Speed: 1 mm/
Cut-off length: 0,25/0,8/2,5 mm
Effective range: Ra:0,05-10,0 m
Rz:0,1-50,0 m Error: 15%
Measuring tip: diamond, R 5,0 m
Dimensions: 1257326 mm
Weight: 200 g
Portable Hardness Tester-1000Dynamic hardness tester with digital display for hardnessmeasurement of any item easily and quickly.
Specifications:
Unit measure: Leeb (HL); Vickers(HV); Brinell (HB); Rockwell B(HRB); Rockwell C (HRC); Shore D (HSD)
Effective range: 200-900 HL
Error: 0,5%
Angle of measurement:
Dimensions: 165x28x28mm
Article No. 134.001.100
Article No. 150.500.100
Article No. 710.010.001
-
7/28/2019 Helling Engl KATALOG
20/42
20
Ultraviolet sources
Stationary ultraviolet lamps
ZERO-400 IP-20
ZERO-400 IP-54
ZERO-800 IP-54
Specifications: ZERO-400IP-20
ZERO-400IP-54
ZERO-800IP-54
Article No. 144.000.404 144.000.403 144.000.801
Input voltage 230 V; 50/60 Hz
Starting current 5 A 10 A
Starting time Less then 5 min
Restarting time Less then 10 min
Ultraviolet radiant 400 2 400
Wave length of UV light 365 nm
Ultraviolet intensity on distance 400 mm 5000 11000
Lifespan of UV source about 1500 hours
Dimensions 500500300
Weight 30 kg 40 kg
Protection class IP20 IP 54
-30-25-20-15-10 -5 0 5 1015
2025
30
1000
2000
3000
4000
5000
6000
7000
8000
9000
-25-20
-15-10
-50
510
1520
25Bestrahlun
gsstrke(W/cm
2)
YAx
is(cm)
XAxis(cm)
Ultraviolet radiation distribution (W/cm2)
of Zero 400
200 220 240 260 280
300
320
340
360 380 400
0
100
200
300
400
500
600
700
800
Helling Zero
(nm)
UVC UVB
Ultraviolet radiation spectral distribution of
Zero 400
Intensity
-
7/28/2019 Helling Engl KATALOG
21/42
21
Handheld ultraviolet lamps
Specifications: Super UV 2005 C 10 A-HE C 10 A-SH C 10 A-SArticle No. 142.000.105 142.000.200 142.000.300 142.000.110
Input voltage 230 V; 50/60 Hz
Starting current 1,60 A 1,85 A 1,85 A 1,85 A
Starting time Less then 5 min
Restarting time Less then 10 min
Ultraviolet radiant HN100
Wave length of UV light 365 nm
Half-width value of UV emission 1,5 nm
Ultraviolet intensity on distance 400 mm 10000 4000 10000 4000
Lifespan of UV source about 1500 hours
Dimensions 20010080 mm 280280140
Weight 5 kg 7,5 kgProtection class IP20
Super UV 2005
C 10 A-HE
C 10 A-SH
C 10 A-S
UVC UVB UVA
200 220 240 260 280 300 320 340 360 380 4000
500
1000
1500
2000
2500
3000
3500
4000
4500
(nm)Ultraviolet radiation spectral distribution
-12-10
-8-6
-4-2
02
46
810
12
0
500
1000
1500
2000
2500
3000
3500
-14-12
-10-8
-6-4
-20
24
68
1012
14
Bestrahlungsstrke(W/cm2)
YAx
is(cm
)
XAxis(cm)
Ultraviolet radiation distribution
0 10 20 30 40 50 60 70 80 90 100 110 1200.01
0.1
1
10
100
1000
t (min.)
Ultraviolet radiation constancy
W/(cm
2nm)
-
7/28/2019 Helling Engl KATALOG
22/42
22
Ultraviolet-LED lamps
Achieved-Change of Generation for handheld lamps!
Specifications:
iAlso available with power supply,
iiPermanent use is possible,
UV-EndoskopUV-Inspector
365-LWGUV-
Inspector 380-RUV-Inspector 365 UV-Inspector 2000
iUV-Inspector 3000
i
Ar ticle No. 142.300.001 142.200.311 142.200.101 142.200.301 142.200.411 142.200.511
Voltage 4,8 V (4x accum) 18 V 24 V
UV-light sour ce 1xUV-LED 1xUV-LED 1xUV-LED 1xUV-LED 4xUV-LED 9xUV-LED
Lifetim e the UV-LED (h.)
approx. 10 000
UV-light intensity(W/cm
2)
6000 at 20mm10000 at50 mm
2000 at 200 mm 3000 at 400 mm 2500 at 400 mm 4000 at 400 mm
Wavelength(nm) 365 365 365 365 365 370
Emission half-width (nm)
8,5 8,5 8,5 8,5 8,5 8,5
Working hours (H) approx. 6ii
approx. 6ii
approx. 4,5ii
approx. 4ii
approx. 4ii
Weight(g.) approx. 550 approx. 550 approx. 250 approx. 300 approx. 1300 approx. 1400
Dimensions (mm) 1000x6 2000x5 170x45 170x45 75x320x110 230x130
Advantages of ultraviolet-LED sources:
High efficiency at low power consumption
Low heat generation
Very long lifetime
Rigid against shock and vibration
Defined wavelength of emission
Safety due to protective low Voltage
Immediately ready for use after switch on
UV-Endoscope
UV-Inspector 365-LWG
UV-Inspector 380
UV-Inspector 365UV-Inspector 2000 UV-Inspector 3000-N
-
7/28/2019 Helling Engl KATALOG
23/42
23
Leak inspection
Bubble methodThe essential matter of the method is as follows:
Registration of local leakages in an under-test item by appearing of indicator gas bubbles in indicator liquid(indicator cover). The method is used for testing the impermeability of reservoirs welded joint, fluid power andgas systems under the overpressure,(which can be created by vacuum pump).Foam-film indicator(Proof Check) is applied on the under-test joint weld and overpressure is generated. Air(check gas), penetrating through the joint weld microflaws, impacts mechanically on foam-film indicator,accumulating on the defective place, deforms it. In this case bubbles or foam swelling can be seen .
Specifications: EV20:
Evacuation rate: 4m3/hour
Vacuum: 800 mbar
Dimensions: 280290225 mmWeight: 10,5 kg
Voltage: 220-230 V (50Hz)
Protection class: IP54
Foam-film indicator Proof Check
and leak indicationVacuum pumpEV 20 for pressure gradient origination
Vacuum rames o di erent con idurations or testin the oint welds im ermeabilit
D
(D: 251200 mm) 600100 mm 600100 mm 300 mm
Article No. 611.001.001Article No. 616.000.001
-
7/28/2019 Helling Engl KATALOG
24/42
24
Hydrogen leak detectorsThe concept of catalitically selective estimation of hydrogen by a special semiconductor sensor is a basis of the
leak detector Mixture of nitrogen (95 %) and hydrogen (5%) is used as an indicator gas. This mixture isntflammable (ISO 10156 )is not toxic or corrosive, nor dangerous to the environment
H1000 9012XRS
Specifications: H1000 9012XRSMinimum detectable concentration of hydrogen 0,5 ppm
Minimum detectable leak of hydrogen 5 10-5 mbar l/s
Reaction time for hydrogen 2sec.
Self-test procedure and warm-up time 1min.
Supply 100-230 V
Continuous work time from accumulator 13 hours
Dimensions 275 155 170 mm 250 120 85 mm
Weight 3 kg 1,9 kg
Helium leak detector PDH-4
The basis of the detector is so called Selective Ion Pump Detector SIPD. Principe of the work is asfollowing: helium is heated up to a certain temperature, penetrates special quartz membrane (which ispermeable only for helium atom). Detector senses helium and sends a signal, which force is proportional to thequantity of helium, having penetrated through the quartz membrane. Signal amplitude represents the size of leak.
Specifications:PDH-4:Minimum detectable concentration of He 2 ppm
Minimum detectable He leak 5 10-7 Pa m3/s
Reaction time for He 2 sec.
Self-test procedure and warm-up time 3 minutes
Supply 18 V, Accumulator
Continuous work time from accumulator 4 hours
Operating conditions
Temperature
Relative humidity
+5 35
90% maximumDimensions 170 136 290 mm
Weight 2,6 kg
Portability High sensitivity Hugh selectivity Easy to use High robustness
-
7/28/2019 Helling Engl KATALOG
25/42
25
Ultrasonic leak detector Hellophone
Leak detectorHellophonedesigned for:Detection of compressed gas, liquid (also viscous) leaks from small holes (flute cracks) in pipeline and
reservoirs
Testing of stop valve (cocks, clappers etc.) in operating objects Compression and joint weld leak testing (if using ultrasonic generator)
Detection of minor electrical discharge in defective contacts of electric installations.
Delivery kit:Ultrasonic device with accumulator power supplyUltrasonic generator
ChargerEarphonesWaterproof probing device for solid bodySolid state probeAir-ultrasonic probe
HellophoneSpecifications: Measuring frequency: 40 Hz1Hz
Digital display LCD
Conservation of max- quantity
Integral accumulator (10 hours of work)
Dimensions: 1206525 (generator)19510040 (receiver)
Weight of the package with the bag: 3,6kg
Article No. 613.100.010Article No. 613.100.001
-
7/28/2019 Helling Engl KATALOG
26/42
26
Fluorescent concentrate for detecting leaks in cooling systems etc.
Luminescent leak testing method is based on the use of special agents (as test medium) - luminophors, whichare emitting visible light under ultraviolet radiation. The location of a leakage is detected by this specificlight emission.
H 800Oil-suspendible concentrate
for detecting leaks in cooling
systems:
flammable oiling materials
synthetic and mineral oils
Consumption: 0,5-2ml/l
Optimum wave length
excitation: 365nm
Color under UV excitation: yellow
H 849Concentrate on water basis with emulsifying additive
and corrosion inhibitor for detecting leaks in cooling
systems, leak testing of different objects
Consumption: 2-5 ml/lOptimum wave length excitation: 365nm
Color under UV excitation: green
Article No. 616.000.033 0,5 LitreArticle No. 616.000.034 1,0 LitreArticle No. 616.000.032 10,0 Litre
Article No. 616.000.035 20,0 kg barrel
Article No. 616.100.103
-
7/28/2019 Helling Engl KATALOG
27/42
27
Radiographic testing
Radiographic film
*Hand developing by use of Fuji-Chemicals at 20C and 5 min developing time**
Machine developing by use of Agfa-Chemicals at 28C and 8 min developing time
Helling GmbH officialdistributor of Fuji Industrial
X-RAY Products
IX 50
An ultra-fine grain, high contrast ASTM Class I film having excellent sharpness and high discrimination characteristics. Itis suitable for use with any low atomic number material where fine image detail is imperative. Its ultra-fine grain makes ituseful in high energy, low subject contrast applications where high curie isotopes or high output X-ray machines permit itsuse. Wide exposure latitude has been demonstrated in high subject contrast applications.IX50 is generally used in directexposure techniques or with lead screens.
IX 80An extremely fine grain, high contrast ASTM Class Ifilm suitable for detection of minute defects. It is applicable to theinspection of low atomic number materials with low kilovoltage X-ray sources as well as inspection of higher atomicnumber materials with high kilovoltage X-ray or gamma ray sources. Wide exposure latitude has been demonstrated inhigh subject contrast applications. IX80 is generally used in direct exposure techniques or with lead screens.
IX 100A very fine grain, high contrast ASTM Class II film suitable for the inspection of light metals with low activity radiationsources and for inspection of thick, higher density specimens with high kilovoltage X-ray or gamma ray sources. Wideexposure latitude has been demonstrated in high contrast subject applications. Although IX100 is generally used in directexposure techniques or with lead screens, it is suitable for use with fluorescent or fluorometallic screens.
IX 150A high speed, fine grain, high contrast ASTM Class III film suitable for inspection of a large variety of specimens with low-to-high kilovoltage X-ray and gamma ray sources. It is particularly useful when gamma ray sources of high activity areunavailable or when very thick specimens are to be inspected. It is also useful in X-ray diffraction work. IX150 is used indirect exposure techniques or with lead screens.
FUJI IX AGFA KODAKFilm category Sensitivity, R-1
IX 50 D 2 M 100 C 2 2,7
IX 80 D 4 M 125 C 3 4,5
IX 100* D 5 T 200 C 4 6,7
IX 100** D 7 AA 400 C 5 11,0
IX 150 D 8 CX C 6 17,0
-
7/28/2019 Helling Engl KATALOG
28/42
28
Format cm Film type
NIF non interleaved package, 100 sheets10 x 24 IX 50, IX 80, IX 100, IX 150
10 x 48 IX 50, IX 80, IX 100, IX 150
13 x 18 IX 80, IX 100, IX 150
24 x 30 IX 50, IX 80, IX 100, IX 150
30 x 40 IX 50, IX 80, IX 100, IX 150
NIF - non interleaved package, roll package (4 items)70 mm 168 m IX 100
EPAK vacuum package with layers, without Pb screen, 50 sheets6 x 24 IX 80, IX 1006 x 48 IX 80, IX 100
10 x 24 IX 50, IX 80, IX 100
10 x 40 IX 80
10 x 48 IX 50, IX 80, IX 100
18 x 24 IX 80
24 x 30 IX 80
30 x 40 IX 80
EPAK - vacuum package with layers, without Pb screen, roll package (2items)
60 mm 61 m IX 80100 mm 61 m IX 80
EPPB vacuum package with Pb screen, 50 sheets6 x 24 IX 50, IX 80, IX 100
6 x 48 IX 50, IX 80, IX 100
10 x 24 IX 50, IX 80, IX 100
10 x 40 IX 50, IX 80, IX 100
10 x 48 IX 50, IX 80, IX 100
18 x 24 IX 50, IX 80, IX 100
24 x 30 IX 50, IX 80, IX 100
30 x 40 IX 50, IX 80, IX 100
EPPB - vacuum package with Pb screen, roll package (2 items.)60 mm 61 m IX 50, IX 80, IX 100
70 mm 61 m IX 50, IX 80, IX 100
100 mm 61 m IX 50, IX 80, IX 100
Chemical agents for processing radiographic film Fuji
Developer Rendol 4 5 l ready to use liquor for hand development
Fixing solution M-FIX 25 l ready to use liquor for hand development
Developer Audel 2 20 l ready to use liquor for automatic
development
Fixing solution AUFIX 2 20 l ready to use liquor for automaticdevelopment
-
7/28/2019 Helling Engl KATALOG
29/42
29
Developing machines for radiographic film
Characteristic data Colenta FNDX1 Article No. 232.010.001Film type Sheet and roll films
Max. film width 36 cm
Development time Controlled from 3 to 13 minutes
Development rate at 8 min. 16 films/hour, Format3543mm
Development temperature Regulated from 18 to 43C
Drying temperature Max. 60C, hot air
Regeneration system Automatic
Capacity charge2,6 l of developer2,5 l of fixer , 3 l of water
Water consumption while working 1,5 l
Water connection 3/4" (3-10 bar)
Supply 220-240 V, 16 , 50-60 Hz
Power consumption 1,7 W, Stand-By (0,35 kW)
Weight 58 kg
Characteristic data Colenta FNDX2Film type Sheet and roll films
Max. film width 43 cm
Development time Controlled from 2 to 10 minutes
Development rate at 8 min. 29 films/hour Format 3543mm
Development temperature Regulated from 18 to 43C
Drying temperature Max. 60C, hot air
Regeneration system Automatic
Capacity charge6 l of developer,6 of fixer, 6 l of water
Water consumption while working 1,5 l
Water connection 3/4" (3-10 bar)
Supply 220-240 V, 16 , 50-60 Hz
Power consumption 3,1 W, Stand-By (0,6 W)
Weight 127 kg
Characteristic data Colenta FNDX3Film type Sheet and roll films
Max. Film width 43 cm
Development time Controlled from 3 to 14 minutes
Development rate at 8 min. 38 films/hour Format3543mm
Development temperature Regulated from 18 to43C
Drying temperature Max. 60C, hot air
Regeneration system Automatic
Capacity charge9 of developer,8 l of fixer, 8 l of water
Water consumption while working 1,5 l
Water connection 3/4" (3-10 bar)
Supply 220-240 V, 16 , 50-60 Hz
Power consumption 3,5 W, Stand-By (0,6 W)
Weight 132 kg
-
7/28/2019 Helling Engl KATALOG
30/42
30
Accessories
Film viewing equipment
Densitometer
Sensitivity standards
Darkroom accessories
Absorbance standard
Packages of lead letters and numbers
Article No. 242.004.000
-
7/28/2019 Helling Engl KATALOG
31/42
31
Ultrasonic testing
Wall thickness measuring device
HELLISON-1
Ultrasonic defectoscope
HELLSTEIN II
Ultrasonic defectoscope
INT-Bond-Tester
Tested materials: Black and nonferrous metals,
hard plastics, glass, ceramics
Effective range: 1-300 mm
Definition: 0,1 mm
Error: 0,5%Ultrasonic transducers: 2; 5: 10 Hz
In-steel calibration
Power Supply: 2,4 V, 2 from AccumulatorDimensions: 1256530 mm
Weight: 200 g
Delivery: ultrasonic thickness indicator, ultrasonic transducer2 Hz, ultrasonic gel 250 ml, charging device.
Detection of defects as homogeneity disfunction in welds,
preformed materials and finished materials. Depth determination
and defects coordinates.
Test range 10-5000mm (in steel)
Velocity range: 1000-9999 m/sGain: 140 dB
Frequency range: 0,5-15Hz
Interface RS232Power Supply: 14 V, Li-AccumDimensions: 15225570 mmWeight: 2,3 kg
Ultrasonic resonance spectroscopy (URS) utilizes information in the
frequency domain obtained due to the constructive and destructiveinterference of elastic waves for nondestructive evaluation of
inspected objects. In a resonance test an ultrasonic tone-burst with
sweeping frequency is applied to an ultrasonic transducer and aresonance spectrum of the inspected structure is acquired. The
acquired spectrum contains information about the properties of
materials used for the structure and flaws that may be present in it.
Measurement setup: Narrowband ultrasonic spectroscopy can be
used for the NDT of aerospace multi-layered structures. The INT-Bond-Tester used for this test operate on the principle of exciting a
mechanical resonance in a multi-layered structure. A piezoelectric
probe, excited by a swept frequency signal is coupled to the surface
of the inspected structure using a coupling agent. The instrumentacquires probes frequency spectrum in the range of some tens of
kHz to several hundreds of kHz. A resonance in the layered structure
occurs when echoes between two boundaries travel back and forth
due to the difference in acoustic impedances at the boundaries.
Article No. 311.000.100
Article No. 311.001.001
-
7/28/2019 Helling Engl KATALOG
32/42
-
7/28/2019 Helling Engl KATALOG
33/42
33
Sample
Sample
Current meter (AC, DC)
High quality steel feeler 0,05-1mm
Pocket lamp
Pocket lens(magnification 3, 6, 9)
Article No. 810.070.002 Article No. 810.080.038
Article No. 810.070.005
Article No. 810.080.039
Article No. 810.080.008
Article No. 220.026.300
Article No. 810.080.009
Article No. 810.080.042
-
7/28/2019 Helling Engl KATALOG
34/42
34
h
Telescopic magnet
Joint weld master made of high quality steel
Thermometer(-70-+1000C)
Depth Gauge
Article No. 810.070.003
Article No. 810.080.003
Article No. 810.080.047
Article No. 810.080.017
-
7/28/2019 Helling Engl KATALOG
35/42
35
Temperature indicators
Surface temperature detection
easy to use, quick and durable
precise (1% fromrated temperature)
temperature range from 38C to 1371C
Surface temperature detection
Self-adhersice labels
easy to use, quick and durable
precise (2% from rated temperature)
temperature range from 38C to 260C
High temperature paint
for surfaces protection, undergoing hightemperature impact
temperature range :up to1093C
Article No. 510.100.000
Article No. 510.200.000
Article No. 518.000.007
-
7/28/2019 Helling Engl KATALOG
36/42
36
HELLING DYKEMTEXPENAND HELLING DYKEMDALOMARKERThe HELLING DYKEM
TEXPEN
stands out for its distinctive fine,
medium and bold oil-based paint markings. Its stainless steel
ball valve action tip writes through oil, grease and underwater without losing legibility or brightness even in extreme weatherconditions.The HELLING DYKEM
DALO
Marker is a marking pen with medium, and bold tips that hold a high capacity of oil-based paint
and it is a larger version of the HELLING DYKEMTEXPEN
.
Benefits:
Write sharp, defined, bright marks on almost any surfaceincluding metal, plastic, glass, concrete, rubber and more
Ergonomically correct marker that enables you to markat all angles, even upside down
Marker retains its shape
Paint flow is controlled by the bulb at the end of the barrel
Drying time: 25-35 minutes
DYKEMTEXPEN colours available
Fine Medium Broad
810.016.030 810.016.020 810.016.033 810.016.023 810.016.034 810.016.024
810.016.010 810.016.080 810.016.013 810.016.083 810.016.014 810.016.084
810.016.040 810.016.060 810.016.043 810.016.063 810.016.044 810.016.064
810.016.100 810.016.103 810.016.104
DYKEMDALO colours available
Medium Broad
810.026.033 810.026.023 810.026.034 810.026.024
810.026.013 810.026.083 810.026.014 810.026.084
810.026.043 810.026.063 810.026.044 810.026.064
810.026.103 810.026.104
HELLING DYKEMBRITE-MARKThe HELLING DYKEM
BRITE-MARK
is a general purpose marker that writes on almost any surface and features different tip
sizes for clear, bold markings. Its quick drying, oil-based paint withstands indoor and outdoor conditions, including acid andalkaline rain without fading, chipping or losing opacity. The HELLING DYKEM
BRITE-MARK
pens can be used to permanently
identify inventory, assemblies, tools, finished products or working-in-progress while resisting most work related abuses orcompounds.
Benefits:
Makes permanent, bright marks on metal, rubber, plastic, glass, concrete,leather, stone, wood, vinyl and more
Valve action mechanism prevents paint in barrel from drying when cap is left off
Threaded end of The HELLING DYKEMBRITE-MARK
40 can be screwed
into a jig or apparatus for continuous identification application Heavy-duty aluminium body
Ideal for colour coding
Bullet tips are replaceable
Drying time: 25-35 seconds
DYKEMBRITE-MARK colours available
Medium Broad 40
810.041.003 810.041.045 810.084.002 810.084.019 810.084.009 810.D40.003 810.D40.045
810.041.001 810.041.002 810.084.001 810.084.006 810.084.006 810.D40.001 810.D40.002
810.041.004 810.041.016 810.084.007 810.084.050 810.016.044 810.D40.004 810.D40.016
810.041.014 810.041.008 810.084.051 810.084.003 810.D40.014 810.D40.008
810.041.010 810.041.006 810.084.005 810.084.004 810.016.104 810.D40.010 810.D40.006
BRITE-MARK Fine
BRITE-MARK Medium
BRITE-MARK 40
-
7/28/2019 Helling Engl KATALOG
37/42
37
HELLING DYKEMRINZ OFFTM and The HELLING DYKEMSUDZ OFFTMThe HELLING DYKEM
RINZ OFF
TMand The HELLING DYKEM
SUDZ OFF
TMwater removable ink marker and the HELLING
DYKEMSUDZ OFF
TMdetergent removable ink marker write on non-treated, non-painted metal, glass, ceramic and some plastic
surfaces and can be removed, leaving no ghosting. The markers feature a fibre tip ink pen that can be used indoors and
outdoors on any smooth nonporous surface and will not react with paint systems (should be tested for suitability). The HELLINGDYKEM
RINZ OFF
TMcan be removed with water while the HELLING DYKEM
SUDZ OFF
TMcan be removed with detergent.
DYKEMRINZ OFF DYKEMSUDZ OFF
Medium Broad Medium Broad
810.091.109 810.044.109 810.091.985 810.091.146 810.044.985 810.044.146810.06.024
810.091.105 810.044.105 810.091.938 810.091.694 810.044.938 810.044.69410.016.084
810.091.108 810.044.108 810.091.371 810.016.063 810.044.371
810.091.106 810.044.106 810.091.939 10.01 6.104 810.044.939
HELLING ACTION MARKERThe HELLING ACTION MARKER
44 and the HELLING ACTION MARKER
Fine Line are dye-based ink pens with a valve
action fibre tip that writes on any smooth surface. The HELLING ACTION MARKER
44 has a threaded end that can bescrewed into a jig or apparatus for continuous identification application. It is used to make broad markings on any smoothsurface, The HELLING ACTION MARKER
Fine Line is lightweight and writes fine, distinctive markings. Both markers feature a
clip to secure the pen in your pocket or on your clipboard.
Benefits:
Permanent ink writes on smooth surfaces such as metal, aluminium, plastic,glass, rubber and more
Inks are able to withstand oil, dirt, grease and extreme weather conditions
Interchangeable and replaceable tips are available
6 to 8 times the writing life of most other capillary markers of comparable size
Drying time: 45 seconds to 1 minute
Colours available
AM 44 Fine Liner
810.044.003 810.044.010 810.033.003 810.033.010
810.044.001 810.044.002 810.033.001 810.033.002
810.044.004 810.033.004
Fine Liner
AM 44
-
7/28/2019 Helling Engl KATALOG
38/42
38
HELLING HIGH TEMPERATURE MARKERS
The HELLING TEXPEN
for high temperatures has a stainless steel-ball valve action tip and heavy viscosity, oil-based paintthat is specially formulated for nonporous surfaces that reach temperatures of up to 2000F/1093C. Marks become permanentand fused when heated. The marker is an ergonomically correct pen that enables you to mark at all angles, even upside down.The bulb at the end of the barrel controls paint flow.
The HELLING ACTION MARKER
44 and HELLING ACTION MARKER
33 for high temperatures are pigmented, oil-basedfibre tip pens that are specially formulated for nonporous surfaces that can reach temperatures up to 2000F/1093C. Marksbecome permanent and fused when heated. Both markers feature a clip to secure the pen in your pocket or on your clipboard.The HELLING ACTION MARKER
44 has an extra large paint capacity. The EHELLING ACTION MARKER
33 is lightweight
and writes fine, distinctive markings.
HELLING ACTION MARKER TEXPEN
colours available
Fine Medium Broad Range of Temperature
810.017.030 810.017.033 810.017.034 1093C / 2000F
810.017.010 810.017.013 810.017.014 1093C / 2000F
810.017.040 810.017.043 810.017.044 1093C / 2000F
810.017.100 810.017.103 810.017.104 426-482C / 800-900F
810.017.020 810.017.023 810.017.024 426-482C / 800-900F
810.017.080 810.017.083 810.017.084 426-482C / 800-900F
810.017.060 810.017.063 810.017.064 426-482C / 800-900F
HELLING ACTION MARKERcolours available
AM3 33 AM 44 Range of Temperature
810.033.250 810.044.250 1093C / 2000F
810.033.094 810.044.094 1093C / 2000F
810.033.266 810.044.266 982C / 1800F
810.033.219 810.044.219 843-899C / 1550-1650F
810.033.424 810.044.424 426-482C / 800-900F
-
7/28/2019 Helling Engl KATALOG
39/42
39
HELLING HIGH PURITY MARKERS
The high purity HELLING TEXPEN
contains trace amounts of halogens, low melting metals and is low in chlorides. Therefore,its stainless steel ball valve tip can be used on surfaces where degradation, contamination or adverse effects are not desired.The high purity HELLING TEXPEN
is an ergonomically correct marker that enables you to mark at all angles, even upside
down. Its oil-based paint withstands extreme weather conditions.
The high purity HELLING ACTION MARKER
44 and HELLINGACTION MARKER
33 are dye and pigment based ink pens with a
valve action fibre tip that write on smooth surfaces. They are verylow in chlorides, so they can be used on surfaces wheredegradation, contamination or adverse effects are not desired. Pensmeet or exceed the requirements of the US Energy Research &Development Administrations Nuclear Grade for black, red, yellowand white inks. The HELLING ACTION MARKER
44 has a
threaded end that can be screwed into a jig or apparatus forcontinuous identification application. The HELLING ACTION MARKER
33 is light weight and writes fine, distinctive markings.
Both markers feature a clip on the pen cap that fits easily into your pocket or on your clipboard.
HELLING TEXPEN colours available
Fine Medium Broad
810.017.470 810.014.100 810.017.473 810.014.103 810.017.474 810.014.104
810.014.210 810.017.460 810.014.213 810.017.463 810.014.214 810.017.464
810.010.350 810.014.140 810.010.353 810.014.143 810.010.354 810.014.144
810.014.200 810.014.203 810.014.204
HELLING ACTION MARKER 44 and HELLING ACTION MARKER 33 colours available
AM 44 AM 33
810.044.404 810.044.729 810.033.404 810.033.729
810.044.534 810.044.916 810.033.534 810.033.916
810.044.301 810.033.301
-
7/28/2019 Helling Engl KATALOG
40/42
40
Delivery program
Penetrant testing
Met-L-Chek / Dub-L-Chek , Standard Chek, Nord-Test,test equipment
Contrast and fluorescent systems
Electrostatic, penetrant and other coating systems
Control devices, UV examination lamps, UV measuring instruments
Magnetic powder testing
Magnetizing devices/test benches
Stationary defectoscopes
Colored and fluorescent magnetic powders
Test bodies
Leak testing
Helium and hydrogen leak detectors
Ultrasonic leak detectors
Vacuum testers with test frames
Colored and fluorescent concentrations
Radiographic testing
Mobile and stationary X-ray equipment and laboratories.
Radiographic accessories, radiographic films, darkroom accessories
Film viewing equipment, film development systems Radiation, measuring and alarm systems
Visual inspection
Rigid and flexible endoscopes
TV camera system
Mirrors, light probes and magnifiers
Ultrasonic testing Wall thickness measuring systems
Ultrasonic defectoscopes
Material test equipment
Control devices and accessories
Thermal inspection
Heat-sensitive crayons, lacquers, labels, inkfrom 38 C to 1371 C
Pyrometer
-
7/28/2019 Helling Engl KATALOG
41/42
41
For Your Notes:
-
7/28/2019 Helling Engl KATALOG
42/42
02.08.2007
top related