hitachi t escalator x series › businesses › elevator › pdf › 20191028_hita… · safety of...
Post on 07-Jun-2020
4 Views
Preview:
TRANSCRIPT
EscalatorHitachi SERIESXT
TX 2019.07Copyright:Hitachi Elevator (China) Co., Ltd.RE-C001Q 0719
CONTENTSHitachi s brand-new TX series escalators materialize to its design concepts of Safety, Reliability,
Comfort and Durability, and continue its commitment to environment-considered and energy-saving,
as well as its pursuits of high quality, which provides efficient and convenient transportation solu-
tions for buildings.
CGs presented in this catalogue are based on the recommended specification of Hitachi, with some options are included. Actual product may vary depending on selected specifications.
Safe and Reliable
Efficiency and Energy-saving
Diversified Design
Product Specification
01-06
07-10
11-14
15-18
,
Note:
01 02
SAFE AND RELIABLEProvide all-around protection for passengers.
These CGs are based on the recommended specification of Hitachi, with some options are included. Actual product may vary depending on selected specifications.
Note:
Safety of step
Safety of landing plate
8mm raised cleats on both sides of step, unique four sides demarcation lines design effectively guide passenger onto the safe standing area to prevent entrapment.
0.5mm convex surface on each stainless steel step the demarcation line area at the rear of each step, which enhance the passenger’s touch feeling of stepping onto,to reduce the risks of slipping.
The safe tooth pitch of step cleat is 8.4mm ,e ffe ct i v e l y p re v e n t t h e high-heeled shoes and umbrellas from being entrapped into its teeth.
The embedded retangular landing plate is fitted onto safe and reliable support structure, to avoid any shifting and falling of landing plate.
The anti-slip pattern meet the assessment group of R10, to effectively prevent the passengers from slipping.(Conforming to DIN51130 standard).
8mm
8.4mm
Anti-collapse
Anti-slip
Convex surface
Anti-slip Anti-collapse
03 04
These CGs are based on the recommended specification of Hitachi, with some options are included. Actual product may vary depending on selected specifications.
Note:
Standard
Standard Standard
OptionalOptional
*:
Safety detection
Electronic safety monitor
Skirt guard safety device (SGS)*
Handrail inlet safety device (TIS)
Comb plate safety device (CMS)
Emergency stop button
Landing plate close abnormity detection(MIS)
Overload, loss of phase and phase reversal protection
Handrail breaking safetydevice (HRS)* Step chain safety
device (TCS)
Emergency brakingsafety gear(H≤6m)
Over-speed, under-speed and reversal safety protection
Missing step protective device (MSD)
Reversal protection
Full range of safety protection devices
Handrail inlet safety device (TIS)
Comb plate safety device (CMS)
Skirt guard safety device (SGS)*
Missing step protective device (MSD)
Handrail running speed abnormity detection (HSD)
Emergency stop button
Driving chain safety device (DCS) Step sinking safety
device (STS)
Landing plate close abnormity detection (MIS)
Magnetic brake safety device (MGS)
Auxilary brake(ABS)*(Standard for H>6m)
Area safety detection device*
Skirt guard safety brush
Emergency Braking Safety Gear can be provided for H≤6m in addition to the main operation brake, for safe braking in the event of chain breakage.
TX escalator entirely enhance the electronic system safety performance. By comparing the operating status of main Machine and Step which improve the redundancy detection, avoiding overspeed and reversal situation, the electronic safety integrity level achieve to SIL3 (higher than EN Standard of SIL2).
Area safety detectionWhen the sensor detects passenger movement beyond the handrail, a voice announcement will alert the passenger.
*Note:Sensor is usually set up on one side where there is obstacle. In case of customer requesting to have sensor on both sides, please contact Hitachi.
Step operation detection Main machine operation detection
Anti-reversal
05 06
Standard
Standard
Optional
Optional
EFFICIENCY AND ENERGY SAVINGAssist the environmentally conscious saving operation, energy-saving buildings.
07 08
Comprehensively improve the drive technology, to achieve better
efficiency and energy saving; in addition, provide choices of
operation modes according to passenger flow, to maximize
customer's benefits .
Hitachi TX Escalator satisfies Class A+++, the highest level specified
in ISO 25745-3 “Energy performance of lifts, escalators and moving
walks -- Part 3”
A+++ ≤ 55%
A++ ≤ 60%
A+ ≤ 65%
A ≤ 70%
B ≤ 80%
C ≤ 90%
D ≤ 100%
E > 100%
A +++Low energy consumption
High energy consumption
Operation mode:
Label No:I0215765 Valid until:14.11.2021
Power off Auto start Slow speed
ISO 25745-3:2015
Auto start-stop operation
Auto dual speed + Auto start-stop operation
When the sensor detects no passenger for a predetermined period of time, the escalator automatically entersthe energy-saving mode. When the sensor detects an approaching passenger, the escalator gradually accelerates to the rated speed.
Energy Saving Mode
Standby speed (Energy-saving mode) Rated speed
Auto dual speed operationSpeed
Standby Speed
Standby Speed
Acceleration Deceleration Standby speedTime
Rated Speed
Rated speed(With passenger)
Standby speed(Without passenger)
Speed
Speed
Stop
StopStop
Acceleration
Acceleration
Deceleration Stop
Deceleration Stop
Time
Time
Rated Speed
Rated Speed
Rated speed (With passenger)
Rated speed (With passenger)
Without passenger
Detection of passenger
Detection of passenger
Detection of passenger
09 10
These CGs are based on the recommended specification of Hitachi, with some options are included. Actual product may vary depending on selected specifications.
Note:
Optional
DIVERSIFIED DESIGNMatch perfectly with buildings.
11 12
Escalators are important features for building passenger traffic. The
decorative configuration of escalator will affect the overall space
architecture in the buildings. As for the upgrade of products, Hitachi
promotes the diversified design, to adapt to the different decoration
styles of shopping malls and buildings.
These CGs are based on the recommended specification of Hitachi, with some options are included. Actual product may vary depending on selected specifications.
Note:
Handrail colors
Step designNote: Printed color and actual color may differ slightly
RedGray Blue Beige Green Brown Charcoal
Balustrade designSimple appearance design of the balustrade,will naturally guide passengers to slip the handrail.Optional LED handrail lights will further enhance architecture design.
LED lighting
13 14
Transparent tempered glass
TX-EN ModelTransparent tempered glass + handrail lighting
TX-L ModelHairline stainless steel
TX-P Model
These CGs are based on the recommended specification of Hitachi, with some options are included. Actual product may vary depending on selected specifications.
Note:
Enhance the space utilization
Expand available space
TX series escalators brand new technological innovation optimizes truss structure size, saving additional space to be used for more valuable purposes for the customers.
Standard
Black
Standard
Optional
Optional
( LED color selection: white, green, red, blue and light-yellow )
Step demarcationlighting
Comb lighting
Handrail lighting( L Model only )
Footlight
Skirt guard lighting( Hidden-type )
White (Standard color)
White (Standard color)
Skirt guard lighting( Stripe-type )
White (Standard color)
White (Standard color)
Green (Standard color)
Green (Standard color)
Standard
Standard for IndoorAluminum alloy
No painting(No demarcation line)
Optional
Option for IndoorStainless steel
Painting Reinforced synthetic resin
Around 4 edges (Fluorescent yellow)
Optional
Standard for OutdoorAluminum alloy
Painting 3 edges yellow boundary
(Painting)
PRODUCT SPECIFICATION
15 16
These CGs are based on the recommended specification of Hitachi, with some options are included. Actual product may vary depending on selected specifications.
Note:
Function
Safety device
Automatic running
Fault handling
Monitoring
Other functions
Step chain safety device(TCS)
Driving chain safety device(DCS)
Comb plate safety device(CMS)
Handrail inlet safety device(TIS)
Step sinking safety device(STS)
Handrail running speed abnormity detection(HSD)
Missing step protective device(MSD)
Landing plate close abnormity detection(MIS)
Magnetic brake safety device(MGS)
Skirt guard safety brush
Over-speed,under-speed and reversal safety protection
Emergency stop button
Overload,loss of phase and phase reversal protection
Fault detection on important components of control panel
Safe stopping distance detection
Emergency braking safety gear
Protection against electrostatic loading
Auxiliary brake(ABS)
Skirt guard safety device(SGS)
Handrail breaking safety device(HRS)
Area safety detection device
Auto Lubrication
Auto dual speed
Auto start-stop
Auto dual speed+auto start-stop
Constant speed only
Running direction indicator
Fault alarm
Fault recording
Fault display at control panel
Fault display at skirt guard
Dry contact interface
EN115-1:2008+A1:2010
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√(H≤6m)
√
√(H>6m)
√(Outdoor)
√(H≤6m)
√
√
√
√(Indoor)
1200 Type 1000 Type
Nominal width (mm)
Step width (mm)
Maximum capacity (persons/h)
Rated speed(m/s)
Angle of inclination
Power supply
1200
1004
6000
0.5
30°/ 35°
50/60Hz,AC 3-phase 220/230/380/400/415/440/460/480V, Single-phase 110/220/230/240V
1000
802
4800
Functional Configuration Standard specifications by escalator model
Fire alarm,shutter gate ,earthquake operation interface(when escalator receives signal, escalator stops)
√
√
√
√
Earthquake sensor
Automatic broadcast
√
√
√
√
√
√
√
Motor
Operation method
Three-phase AC induction motor
Key switch operation,reversible
Operating environment Indoor/Outdoor
*1:Setting value of leakage current detector ≥300 (mA)
17 18
TX-EN TX-LModelName
Balustrade
Floor
Step
- -LED (White)
Interior panel
Handrail lighting
Handrail
Skirt guard
Inner and outer deck
Skirt guard lighting
Footlight
Comb
Comb plate
Landing plate
Comb lighting
Step cleat and step riser
Demarcation lighting
Polyurethane (Black)
Indoor: Painted steel, Outdoor: Raw stainless steel
Indoor: Painted steel, Outdoor: Hairline stainless steel
Hidden-type/Strip-type LED (White)
LED (White)
Reinforced synthetic resin (Fluorescent Yellow)
Aluminum alloy
Aluminum alloy
LED (Green)
Indoor:Aluminum alloy (No painting) , Outdoor: Aluminum alloy
Indoor: No demarcation lineOutdoor: 3 edges yellow boundary (Painting)
LED (Green)
Transparent tempered glass Hairline stainless steel
TX-P
Demarcation line
Standard
Standard
Standard
Optional
Optional
Optional
Power Supply Sourcefrom Building
3-Phase/ FrequencyEscalator Motor
Capacity (kW)Model
220V,230V50/60Hz
1000 TypeH≤ 5500
5500< H ≤ 7500
7500< H ≤ 9500
H≤ 4500
4500< H ≤ 6000
6000< H ≤ 9500
5.5
7.5
11
5.5
7.5
11
40
50
63
40
50
63
≥ 40
≥ 50
≥ 63
≥ 40
≥ 50
≥ 63
D
D
D
D
D
D
12.5
16
18
12.5
16
18
4
8
10
4
8
10
1200 Type
380-415V,440V,460V,480V 50/60Hz
1000 TypeH≤ 5500
5500< H ≤ 7500
7500< H ≤ 9500
H≤ 4500
4500< H ≤ 6000
6000< H ≤ 9500
5.5
7.5
11
5.5
7.5
11
32
32
40
32
32
40
≥ 32
≥ 32
≥ 40
≥ 32
≥ 32
≥ 40
D
D
D
D
D
D
12.5
16
18
12.5
16
18
4
6
8
4
6
8
1200 Type
Rise H(mm)Control Panel
Circuit Breaker Size (A)
RequiredBuilding Side
Circuit Breaker Required
Building SideTransformer
(kVA)
MinimumSection Area
for GND (earthing)Wire
(sqmm)Current(A)*1 Curve
√
√
√
Standard Optional
Escalator planning data for 30°Escalator planning data for 30°Applicable for Rise H ≤ 6000mm Applicable for Rise 6000mm<H≤9500mm
*1. If no bottom lights or pipelines need to be installed between the truss and the exterior panel, this dimension is 70mm at the inclined section and 90mm at the horizontal section.*2. When the distance between the center line of handrail and the escalator or any obstacle in the building is less than 500mm, vertical deflector without any sharp edges shall be installed at the intersection. *3. Dimension of bearing plate for both ends : 150mm (W)×20mm (T)×1590mm (L) [1200 type]/1390mm(L) [1000type].*4. If L is more than 15102mm, an intermediate support beam is required. K,M,N,J≤15100 mm.*5. Upon planning, the gaps(clearances) between Escalator and building at both upper and lower part must be designed within the range of 40~90mm including the tolerance at the building side.
Note:
(Unit: mm) (Unit: mm)
Escalator plan view
Escalator side view Escalator front view
Details of supports onboth ends
Frame supporting portion Frame supporting portion(Construction)
140
320
Truss Frame of landing plate
5×M20 Bolt
Bearing plate*3(By others)
1200
type
: 970
(100
0 typ
e: 77
0)
1200
type
: 159
0 (10
00 ty
pe: 1
390)
1200
type
: 485(
1000
type
: 385
)
Length of bearing plate
140
20
Finished Floor Level(By others)
Bearing Plate*3(By others)(welded to the reinforced steel bars)
27050
Landing Plate
Steel Angle200×200×20
Truss
Floor Finishing Level(By others)
130
110±
10
150270
30
80
130
110±
10
140
1920
(Lower) (Upper)
Finished Floor Level(By others) Finished Floor Level(By others)
WP
W6
Landing plate
WPBarrier(By others)
W3
Overall Dimension (Width)(mm)
W (Balustrade)
W1 (Step)
W2 (Handrail)
W3 (Landing plate)
W4 (Truss)
W5 (Total width of escalator)
W6 (Min.pit/opening)
1200 Type 1000 Type
1026
802
1036
1350
1310
1350
1390
1226
1004
1236
1550
1510
1550
1590
Reaction Load(N)
R1ModelNo.
1
2
3
4
5
6
7
8
9.2H+35000
9.2H+38600
5.2K+14000
5.2K+14000
8.4H+33000
8.4H+36200
4.6K+14000
4.6K+14000
R2
9.2H+28000
9.2H+31360
5.2N+4000
5.2M+4000
8.4H+26000
8.4H+28960
4.6N+4000
4.6M+4000
R3
-
-
5.2(K+N)+5000
5.2(K+J)+5000
-
-
4.6(K+N)+5000
4.6(K+J)+5000
R4
-
-
-
5.2(J+M)+2000
-
-
-
4.6(J+M)+2000
2
3
4
2
3
4
1200 Type
H≤9500
1000 Type
Number of supporting
beam
2
3
2/3
2/3
2
3
2/3
2/3
Number offlat step
RiseH(mm)
Escalator plan view
External Dimension(Length)(mm)
2430
2830
3230
2930
2830
No. of flat stepStandardEN115-1 2008+A1(2010)
1000Type1200Type
H≤6000
6000<H≤7500
7500<H≤9500
2
3
3
3
Code Type Rise No. offlat steps
A (mm)
380~415V50/60Hz
220,230,440,460,480V50/60Hz
W3
(Lower) (Upper)
Finished Floor Level(By others) Finished Floor Level(By others)
WP
Landing plate
WPBarrier(By others)
W6
Exterior PanelSide & Bottom(By others)
1000
920
1950≥2500
30°
2200 ≥2500
700
920
1025
200(70)*1
≥12
00
Rise
H
1.732HL*4( =1.732H+2680+A)
2580 A50*5 50*5
1100
A-150
880
800
200(
90)
200
200
(Max.Load:7.2H+49000N)φ 150 Hoisting Hole(By others)
(Max.Load:7.2H+49000N)φ 150 Hoisting Hole(By others)
≥1.732x(o.h+2300)+A+50
≥23
00
(Max.Load:7.2H+33300N)φ 150 Hoisting Hole(By others)
o.h
vertical deflector*2(By others) Barrier(By others)
WP
≥4790
R4
R3
450
WP
450
Power Supply on right handside of top machine(By others)
M*4
N*4
J*4 K*4
20 W5 20
W1WW2
Finished Floor Level(By others)
Finished Floor Level(By others)
Exterior Panel(By others)
Access restriction device(By others)
1100
W4W6
Finished Floor Level(By others)
Finished Floor Level(By others)
Exterior Panel(By others)
Access restriction device(By others)
1100
20 W5 20
W1W
W2
W4W6
【 】:With the condition of H≤6000 with 3 flat steps (optional spec)
φ150 Suspension Hole(By others)
φ150 Suspension Hole(By others)
30°
WP
(Max.Load:7.2H+29400N)
≥1.732x(o.h+2300)+A+50
vertical deflector*2 (By others)
WP
Power Supply on right handside of top machine(By others)
Barrier(By others)
Exterior PanelSide & Bottom(By others)
(Max.Load:7.2H+43100N)
1000
920
1550≥2500
≥23
00
1800 ≥2500
700
920
1025
200(70)*1
≥12
00
Rise
H
1.732HL*4(=1.732H+2280+A)【(=1.732H+2680+A)】
【2580】
【4790】
N*4 K*4
【2200】
【1950】
2180 A50*5 50*5
1100
A-150
880800
200(
90)
≥4390
o.h
200
200
F.F.L
F.F.L
450
Escalator side view Escalator front view
inclination escalator inclination escalator
Intermediate frame supporting beam portion
W4
W4-230
≥50 230230
(100
) 450
180300≥50 230≥50 ≥25 ≥50
100
≥25
TrussIntermediate Support
Support Beam(By others)
Bearing Plate(400(L)×305(W)×20(T))
(By others)Support Beam
Bearing Plate(By others)(By others)
21 22
Escalator planning data for 35°Applicable for Rise H ≤ 6000mm
Note:
Details of supports on both ends
Frame supporting portion Frame supporting portion(Constrution)
(Unit: mm)
Escalator plan view
φ150 Suspension Hole(By others)
φ150 Suspension Hole(By others)
R1
Barrier(By others)vertical deflector*1(By others)
(Max.Load:7.2H+29400N)
(Max.Load:7.2H+43100N)
35°
Power Supply on right handside of top machine(By others)
Exterior PanelSide & Bottom(By others)
WP
WP
≥1.428x(o.h+2300)+A+50
1000
920
1580≥2500
≥23
00
1870 ≥2500
700
920
1025
≥12
00
Rise
H
1.428HL(=1.428H+2310+A)
2210 A50*4 50*4
1100
A-150
800900
200(70) *1
200(
90)
o.h
200
F.F.L
200
≥4180
Escalator side view Escalator front view
20
Finished Floor Level(By others)
Bearing Plate*3(By others)(welded to the reinforced steel bars)
130
110±
10
150270
3027050
Landing Plate
Steel Angle200×200×20
Truss
Floor Finishing Level(By others)
80
130
110±
10
140
140
320
Truss Frame of landing plate
5×M20 Bolt
Bearing plate*3(By others)
1200
type
: 970
(100
0 typ
e: 77
0)
1200
type
: 159
0 (10
00 ty
pe: 1
390)
1200
type
: 485(
1000
type
: 385
)
Length of bearing plate
140
F.F.L
Detail E(F and E are symmetric)
Escalator front viewEscalator side view
Escalator plan view
Architectual requirement for outdoor escalator(Unit: mm)
≥2500
≥23
00
≥2500
≥12
00
R1
Rise
H
WP
WP
1450
R2
E
F
200(70)
420
Step
Truss
Drain slope 1/10(By Others)Drain hole(200×200×200)(By Others)
Drain Diameterφ100(By Others)
Barrier(By Others)Vertical deflector(By Others)
Exterior PanelSides & Bottom(By Others
Drain(By Others)
h≥30
β=1/
10
100≤S≤300 300≤T≤500 U
S: 100-300mm.
T: 300-500mm(Slope1/10).
U: Cutter(With Cover Plate).
Consumer should set the slope and gutter according to Detail E.
Joint Of The Escalator And Floor Cover Plate(By Others)
(Lower) (Upper)
Finished Floor Level(By others) Finished Floor Level(By others)
Barrier(By others)
W6
Landing plate
W3
WP WP
W3
(Lower) (Upper)
TS
U
ST
TS
U
U
UTS390
420
Finished Floor Level(By others)Finished Floor Level(By others)
Drain(By Others) Barrier(By Others)
W4
Finished Floor Level(By others)
Finished Floor Level(By others)
Exterior Panel(By others)
Access restriction device(By others)
1100
20W2W5 20
W1W
W6
inclination escalator
External Dimension(Length)(mm)
*1. If no bottom lights or pipelines need to be installed between the truss and the exterior panel, this dimension is 70mm at the inclined section and 90mm at the horizontal section.*2. When the distance between the center line of handrail and the escalator or any obstacle in the building is less than 500mm, vertical deflector without any sharp edges shall be installed at the intersection. *3. Dimension of bearing plate for both ends: 150mm (W)×20mm(T)×1590mm (L) [1200 type]/1390mm(L) [1000type].*4. Upon planning, the gaps(clearances) between Escalator and building at both upper and lower part must be designed within the range of 40~90mm including the tolerance at the building side.
Note:
Overall Dimension (width)(mm)
W (Balustrade)W1 (Step)
W2 (Handrail)W3 (Landing plate)
W4 (Truss)W5 (Total width of escalator)
W6 (Min.pit/opening)
1200 Type 1000 Type
1026802
10361350131013501390
1226100412361550151015501590
Reaction Load(N)
H≤6000 28.2H+36000 8.2H+28000
Rise H (mm) No. of supporting point R1 R2Model
1200 Type
1000 Type 7.5H+33000 7.5H+26000
R2
2500 2900StandardEN115-1 2008+A1(2010)
1000Type1200Type H≤6000 2
Code Type Rise No. offlat steps
A (mm)380~415V50/60Hz
220,230,440,460,480V50/60Hz
W6W6
W6
Finished Floor Level(By others)
Finished Floor Level(By others)
Exterior Panel(By Others)
Barrier(By Others)
20 W5 20
W1
W4
WW2
F
F
E
E
1450
W6
≥30°
Canopy(By Others)
Work done by others for escalators
Item Work Description
15.
16.
17.
18.
19.
20.
21.
22.
23.
Main power supply for the drive motor: lead-in up to the upper control board of the escalator.
Power supply for inspection and maintenance : lead-in up to the upper control board of the escalator.
Grounding wire: lead-in up to the upper power receiving panel of the escalator.
Piping and wiring for the supervisory panel: lead-in from the installation area of the supervisory panel to the power receiving panel of the escalator.
Piping and wiring work if the escalator's operation panel is separately installed (built into the wall, etc).
Selector switch and its installation for escalator bottom lighting.
Installation of emergency lighting.
Installation of sprinklers, broadcasting speakers, guide lights, etc.
The intensity of illumination at the entrance and exit of escalator shall be at least 50 lux and 15 lux respectively.
Construction related work (Supply and install)
1.
2.
3.
Opening of holes in floor slabs for installation use and recovery work.
Installation of supporting beams for installation use.
Opening of suspension holes in floor slabs or sleeve holes for carrying the escalator into place and performing recovery work.
Item Work Description
Finishing work for floors and ceilings around the escalator after completion of escalator installation.
Installation & finishing works to barrier and walls around the escalator.
External panels on escalator frame (truss).
Installation of triangular caution mark in places where the escalator and building ceiling or one escalator and another intersects.
If the space between escalators is a stairwell, installation of intermediate down walls, ceilings, handrails, and advance prevention partitions.
Joint work in places where the escalator and the building's ceiling border.
Preparation of an entrance to carry in the escalator and perform recovery work if the escalator is to be installed in an existing building.
Protection work around the escalator if the escalator is to be installed in an existing building.
Opening of a hole in the wall if the operation panel of the escalator is to be installed in the building's wall.
Lowest floor and escalator bottom pits and waterproofing work.(if there is any resident room below the lower machine room, the pit work will be of refractory construction).
5.
6.
7.
8.
9.
10.
12.
13.
14.
4.
11. Installation of fall protection nets, etc, if the space between the escalator and the building's floor is stairwell or the space between one escalator and another is a stairwell.
Electrical equipment related work(Supply and install)
23 24
These CGs are based on the recommended specification of Hitachi, with some options are included. Actual product may vary depending on selected specifications.
Note: