Key features

•Optimizedfordatacenterswithextensivevirtualizationandconvergencefeatures

•Broadinterfaceoptionsfrom1Gto100Gscalingupto24.3Tb/sswitchingcapacity

•SDNreadywithOpenFlow1.3support

•LargeLayer2andLayer3tablestosupportlargescaledeployments

•Fullyredundantarchitecturewithhotswappablecomponents

Product overview

TheHP12500SwitchSeriesisafamilyofpowerful,next-generationroutingswitcheswithoutstandingcapacityandscaleforthenetworkcoreordatacenter.

DesignedforhighperformancewithnonblockinganddistributedClosarchitecture,theseswitchesdeliverupto24.3Tb/sswitchingcapacityand10.8Bppsthroughputwithupto400Gb/sperlinecardslot.

The12500switchesalsohaveenergy-efficiencyfeaturesthatdrivedownoperationalexpensesandareidealfororganizationscontemplatinglarge-scaledatacenterconsolidations,businesscontinuityanddisasterrecoverysites,metropolitanareanetworkdeployments,andotherapplicationsrequiringarobust,reliable,andhighlyavailableswitchingplatform.

Data sheet

HP 12500 Switch Series

2

Data sheet | HP 12500 Switch Series

Features and benefits

Data center optimized•NEWScalableLayer2fabrics

Buildflexible,resilient,andscalableLayer2fabricswithSPBandHPIRF

•MultitenantDeviceContext(MDC)

Isaninnovativedatacentervirtualizationsolutionthatenablesmulti-tenancy,givingcustomerstheabilitytovirtualizeaphysicalswitchintomultiplelogicaldevices,witheachlogicalswitchhavingitsowntenants

•HPEthernetVirtualInterconnect(EVI)

IsanHPVirtualApplicationNetworkinnovationthatprovidesaLayer2extensionacrossthedatacentertosimplifytheinterconnectivityofgeographicallydispersedatacenters

•NEWDataCenterBridging(DCB)protocols

ProvidesupportforIEEE802.1QazDataCenterBridgingExchange(DCBX),EnhancedTransmissionSelection(ETS),andIEEE802.1QbbPriorityFlowControl(PFC)forconvergedfabrics

•NEWFibreChanneloverEthernet(FCoE)features

DeliversupportforFCoE,includingexpansion,fabric,trunkVFandNports,andaggregationofE-portandN-portvirtualization

•Acceleratedperformancewithjumboframes

Forintra-data-centercommunication,orfordatacentertodatacentertraffic(disasterrecovery),reducingtheamountoftimerequiredfordatabackupandrecovery

•Networkloadbalancing(NLB)multicastARP

Microsoft®NLBco-workswithmulticastARPtoprovideserverswithloadbalancingandfaultswitchover,whichlowerscostsandinvestment

3

Data sheet | HP 12500 Switch Series

Software-defined networking•NEWSupportsOpenFlow1.3specifications

ToenableSDNbyallowingseparationofthedata(packetforwarding)andcontrol(routingdecision)paths

Performance•NEWHighperformancedesignwithnonblockinganddistributedClosarchitecture

Deliversupto24.3Tb/sswitchingcapacityand10.8Bppsthroughputwithupto400Gb/sperlinecardslot

•NEWHigh-density1/10/40/100GbEinterfaceconnectivity

Offersupto18interfacemoduleslotstoscaleupto8641GbEor1/10GbEor28840GbEor72100GbEports

•Hardware-basedwirespeedaccesscontrollists(ACLs)

Helpprovidehighlevelsofsecurityandeaseofadministrationwithoutimpactingnetworkperformancewithafeature-richTCAM-basedACLimplementation

•High-performanceprocessorsystem

Thesupervisormoduleusesthreedifferentprocessorstoisolatekeytasks:controlplane(STP,OSPF,BGP,MPLS,etc.),fastrecoveryprotocols(RRPP,BFD,etc.),andchassismanagement(temperature,power,etc.)

Product architecture•Distributedarchitecturewithseparationofdataandcontrolplanes

Deliversenhancedfaulttoleranceandfacilitatescontinuousoperationandzeroservicedisruptionduringplannedorunplannedcontrol-planeevents

•AdvancedComwaremodularOS

Bringsmodularity,enhancedserviceability,stabilityandindependentprocessmonitoringthroughmodernComwarev7OperatingSystem

•In-ServiceSoftwareUpgrade(ISSU)

Providesanupgradeoftheentirechassis,oranindividualtaskorprocess,withzeropacketloss

4

Data sheet | HP 12500 Switch Series

Resiliency and high availability•IntelligentResilientFramework(IRF)

Createsvirtualresilientswitchingfabrics,wheretwoormoreswitchesperformasasingleL2switchandL3router;switchesdonothavetobeco-locatedandcanbepartofadisaster-recoverysystem;serversorswitchescanbeattachedusingstandardLACPforautomaticloadbalancingandhighavailability;caneliminatetheneedforcomplexprotocolslikeSpanningTreeProtocol(STP),Equal-CostMultipath(ECMP),orVRRP,therebysimplifyingnetworkoperation

•Ultrafastprotocolconvergence

EnableslinkconnectivitymonitoringandreducesnetworkconvergencetimeforRIP,OSPF,BGP,IS-IS,VRRP,MPLS,andIRF

•DeviceLinkDetectionProtocol(DLDP)

Monitorslinkconnectivityandshutsdownportsatbothendsifunidirectionaltrafficisdetected,preventingloopsinSTP-basednetworks

•Completesetofroutingprotocols(Layer3IPv4andIPv6)

SupportingwiderangeofroutingprotocolsincludingRIP,OSPF,IS-IS,andBGPforbothIPv4andIPv6alongwithcompletesupportofPIM-DM,PIM-SM,PIM-SSM,andMSDP

•Hotpatching

The12500SwitchSeriessupportshotpatching,allowingin-servicepatchingforsomeisolatedsoftwareproblems

•NonStopForwarding/GracefulRestart(NSF/GR)

Usingstandardized-basedIETFprotocols,the12500SwitchSeriesprovidesnonstopforwarding(switching/routing)forLayer3routingprotocols(controlplane–OSPF,BGP,andMPLS),providinghitlessfailover

•Fullyredundantandhotswappablecomponents

Providingfullhardwareredundancyforeachcomponentincludingpowersupplies,fantrays,supervisormodules,andfabricmodulestoenablethehighestlevelofavailability

•RapidRingProtectionProtocol(RRPP)

ProvidesfastrecoveryforringEthernet-basedtopology

5

Data sheet | HP 12500 Switch Series

Quality of Service (QoS)•VirtualOutputQueue(VOQ)

Preventshead-of-line(HOL)blockingandgracefullyhandlesburstydatacentertrafficincreasingswitchperformance

•IEEE802.1pprioritization

Deliversdatatodevicesbasedonthepriorityandtypeoftraffic

•Layer4prioritization

EnablesprioritizationbasedonTCP/UDPportnumbers

•Broadcastcontrol

Allowslimitationofbroadcasttrafficratetocutdownonunwantednetworkbroadcasttraffic

•Advancedclassifier-basedQoS

ClassifiestrafficusingmultiplematchcriteriabasedonLayer2,3,and4information;appliesQoSpoliciessuchassettingprioritylevelandratelimittoselectedtrafficonaper-portorper-VLANbasis

•Bandwidthshaping

– Port-basedratelimiting

Providesper-portingress-/egress-enforcedmaximumbandwidth

– Classifier-basedratelimiting

UsesACLstoenforcemaximumbandwidthforingress/egresstrafficoneachport

Compartmentalization•Departmentprotection

Usingnetworkvirtualizationstandards(QinQ,VRF,andMPLS),the12500SwitchSeriesallowsorganizationstoisolatedifferentbusinessunitswithdifferentresources(VRFs);usingstandard-basedmechanisms,thenetworkiscompletelyvirtualized,reducingcostandoperations

•IEEE802.1ahProviderBackboneBridge(MACinMAC)

ProviderBackboneBridge(PBB)isaLayer2VPNtechnologythatallowsacompleteseparationofcustomerandproviderdomainsbysealingtheuserMACintheserviceproviderMAC,whichenhancesthescalabilityofanEthernetnetwork

6

Data sheet | HP 12500 Switch Series

Layer 2 switching•MultipleVLANRegistrationProtocol(MVRP)

HelpstomaintainVLANconfigurationdynamicallybasedoncurrentnetworkconfigurations

•GARPVLANRegistrationProtocol

AllowsautomaticlearninganddynamicassignmentofVLANs

•IPmulticastsnoopinganddata-drivenIGMP

AutomaticallypreventsfloodingofIPmulticasttraffic

•IEEE802.1adQinQ

IncreasesthescalabilityofanEthernetnetworkbyprovidingahierarchicalstructure;connectsmultipleLANsonahigh-speedcampusormetronetwork

•BridgeProtocolDataUnit(BPDU)tunneling

TransmitsSTPBPDUstransparently,allowingcorrecttreecalculationsacrossserviceproviders,WANs,orMANs

•VLANsupportandtagging

SupportsIEEE802.1Q(4KVLANIDs)

•SpanningTree

The12500SwitchSeriessupportstheentiresetofSTPprotocols(STP,RSTP,andMSTP),facilitatingacompleteintegrationwithstandardnetworks

Layer 3 routing•Layer3IPv4routing

ProvidesroutingofIPv4atmediaspeed;supportsstaticroutes,RIPandRIPv2,OSPF,IS-IS,andBGP

•RIPandRIPngsupport

ProvidescompletesupportofRIPforbothIPv4andIPv6

•OSPFandOSPFv3support

ProvidescompletesupportofOSPFforbothIPv4andIPv6

•IS-ISandIS-ISv6support

ProvidescompletesupportofIS-ISforbothIPv4andIPv6

•Equal-CostMultipath(ECMP)

Enablesmultipleequal-costlinksinaroutingenvironmenttoincreaselinkredundancyandscalebandwidth

•Layer3IPv6routing

ProvidesroutingofIPv6atmediaspeed;supportsstaticroutes,RIPng,OSPFv3,IS-ISv6,andBGP4+

•IPv6tunneling

AllowsasmoothtransitionfromIPv4toIPv6byencapsulatingIPv6trafficoveranexistingIPv4infrastructure

7

Data sheet | HP 12500 Switch Series

•Completemulticastprotocolstack

PIM-DM,PIM-SM,PIM-SSM,MSDP,andextensionstoBGPprovideoneofthemostcompletemulticastprotocolstacks

•Policyrouting

Allowscustomfiltersforincreasedperformanceandsecurity;supportsACLs,IPprefix,ASpaths,communitylists,andaggregatepolicies

•MPLSsupport

ProvidesextendedsupportofMPLS,includingMPLSVPNsandMPLSTrafficEngineering(MPLSTE)

•VPLSsupport

ProvidesextendedsupportofVPLSfordatacentertodatacentercommunicationatLayer2;providessupportofhierarchicalVPLSforscalability

Management•sFlow

Providesscalable,ASIC-basednetworkmonitoringandaccounting;thisallowsnetworkoperatorstogatheravarietyofsophisticatednetworkstatisticsandinformationforcapacityplanningandreal-timenetworkmonitoringpurposes

•IEEE802.1abLLDPdiscovery

Advertisesandreceivesmanagementinformationfromadjacentdevicesonanetwork,facilitatingeasymappingbynetworkmanagementapplications

•USBsupport

– Filecopy

AllowsuserstocopyswitchfilestoandfromaUSBflashdrive

•Multipleconfigurationfiles

Storeseasilytotheflashimage

•Command-lineinterface(CLI)

Providesasecure,easy-to-useCLIforconfiguringthemoduleviaSSHoraswitchconsole;providesdirectreal-timesessionvisibility

•Logging

ProvideslocalandremoteloggingofeventsviaSNMP(v2candv3)andsyslog;provideslogthrottlingandlogfilteringtoreducethenumberoflogeventsgenerated

•Managementinterfacecontrol

Enablesordisableseachofthefollowinginterfacesdependingonsecuritypreferences:consoleport,telnetport,andSSHport

•Out-of-bandinterface

Isolatesmanagementtrafficfromuserdataplanetrafficforcompleteisolationandtotalreachability,nomatterwhathappensinthedataplane

8

Data sheet | HP 12500 Switch Series

•Networkmanagement

HPIntelligentManagementCenter(IMC)centrallyconfigures,updates,monitors,andtroubleshoots

•Networkmanagement

SNMPv2c/v3MIB-IIwithtraps

•RADIUSaccounting

Logsallsessiondetailsthatcanbeusedtogenerateusagereportsorinterfacetoabillingsystem

•RMON

Providesadvancedmonitoringandreportingcapabilitiesforstatistics,history,alarms,andevents

•RemoteIntelligentMirroring

MirrorsingressACL-selectedtrafficfromaswitchportorVLANtoalocalorremoteswitchportanywhereonthenetwork

Connectivity•IPv6nativesupport

– IPv6host

EnablesswitchestobemanagedanddeployedattheIPv6network’sedge

– Dualstack(IPv4andIPv6)

TransitionsfromIPv4toIPv6,supportingconnectivityforbothprotocols

– MulticastListenerDiscovery(MLD)snooping

ForwardsIPv6multicasttraffictotheappropriateinterface

– IPv6ACL/QoS

SupportsACLandQoSforIPv6networktraffic,preventingtrafficflooding

– IPv6routing

SupportsIPv6staticroutesandIPv6versionsofRIPandOSPFroutingprotocols

9

Data sheet | HP 12500 Switch Series

Security•ControlPlanePolicing(CoPP)

ProtectionagainstDoSattacksatinfrastructureroutersandswitches;easeofconfigurationforcontrolplanepolicies

•IEEE802.1XandRADIUSnetworklogins

Controlsport-basedaccessforauthenticationandaccountability

•SecureFTP

Allowssecurefiletransfertoandfromtheswitch;protectsagainstunwantedfiledownloadsorunauthorizedcopyingofaswitchconfigurationfile

•Switchmanagementlogonsecurity

HelpssecureswitchCLIlogonbyoptionallyrequiringeitherRADIUSorTACACS+authentication

•DHCPprotection

BlocksDHCPpacketsfromunauthorizedDHCPservers,preventingdenial-of-serviceattacks

•DynamicARPprotection

BlocksARPbroadcastsfromunauthorizedhosts,preventingeavesdroppingortheftofnetworkdata

•SecureShell(SSHv2)

Encryptsalltransmitteddataforsecure,remoteCLIaccessoverIPnetworks

•Securemanagementaccess

Deliverssecureencryptionofallaccessmethods(CLI,GUI,orMIB)throughSSHv2andSNMPv3

•ACLs

ProvideIPv4andIPv6filteringbasedonsource/destinationIPaddress/subnetandsource/destinationTCP/UDPportnumber

•Mediaaccesscontrol(MAC)authentication

Providessimpleauthenticationbasedonauser’sMACaddress;supportslocalorRADIUS-basedauthentication

Convergence•Layers2,3,and4QoSmechanisms

SupportDiffServprioritytaggingbasedonIPaddress,IPTypeofService(ToS),Layer3protocol,TCP/UDPportnumber,andsourceport

•IPmulticastsnoopinganddata-drivenIGMP

AutomaticallypreventfloodingofIPmulticasttraffic

•LLDP-MED

Isastandardextensionthatautomaticallyconfiguresnetworkdevices,includingLLDP-capableIPphones

•InternetGroupManagementProtocol(IGMP)

UtilizesAny-SourceMulticast(ASM)orSource-SpecificMulticast(SSM)tomanageIPv4multicastnetworks;supportsIGMPv1,v2,andv3

•ProtocolIndependentMulticast(PIM)

DefinesmodesofInternetIPv4andIPv6multicastingtoallowone-to-manyandmany-to-manytransmissionofinformation;supportsPIMDenseMode(DM),SparseMode(SM),andSource-SpecificMode(SSM)

10

Data sheet | HP 12500 Switch Series

•MulticastSourceDiscoveryProtocol(MSDP)

AllowsmultiplePIM-SMdomainstointeroperate;isusedforinter-domainmulticastapplications

•MulticastVLAN

AllowsmultipleVLANstoreceivethesameIPv4orIPv6multicasttraffic,lesseningnetworkbandwidthdemandbyreducingoreliminatingmultiplestreamstoeachVLAN

Monitor and diagnostics•Portmirroring

Enablestrafficonaporttobesimultaneouslysenttoanetworkanalyzerformonitoring

•Connectivityfaultdetection(IEEE802.1ag)

Connectivityfaultdetection(CFD)providesaLayer2linkOperations,Administration,andMaintenance(OAM)mechanismusedforlinkconnectivitydetectionandfaultlocating

Integration•12500VPN20Gb/sFirewallModule

Providesenhancedstatefulpacketinspectionandfiltering;supportsflexiblesecurityzonesandvirtualfirewallcontainment;deliversadvancedVPNserviceswith3DESandAESencryptionathighperformanceandlowlatency;offersWebcontentfilteringandapplicationprioritizationandoptimization

Investment protection•Modularswitchfabric

Providesinvestmentprotectionbyenablingfutureperformanceupgradesandincreasedportdensity

•Environmentallyfriendly

ROHSsupportandlowpowerconsumptionbasedonthelatesttechnologyprovideoutstandingpowerefficiency

Warranty and support•1-yearwarranty

Advancehardwarereplacementwith10-calendar-daydelivery(availableinmostcountries)

•Electronicandtelephonesupport

Limitedelectronicandbusiness-hourstelephonesupportisavailablefromHPfortheentirewarrantyperiod;toreachoursupportcenters,refertohp.com/networking/contact-support;fordetailsonthedurationofsupportprovidedwithyourproductpurchase,refertohp.com/networking/warrantysummary.

•Softwarereleases

Tofindsoftwareforyourproduct,refertohp.com/networking/support;fordetailsonthesoftwarereleasesavailablewithyourproductpurchase,refertohp.com/networking/warrantysummary.

11

Data sheet | HP 12500 Switch Series

HP 12504 AC Switch Chassis (JC654A) HP 12504 DC Switch Chassis (JC655A) HP 12508 AC Switch Chassis (JF431C)

I/O ports and slots 4openmoduleslots

Supportsamaximumof192GigabitEthernetportsor1921/10GbEportsor6440GbEportsor16100GbEports,oracombination

4openmoduleslots

Supportsamaximumof192GigabitEthernetportsor1921/10GbEportsor6440GbEportsor16100GbEports,oracombination

8openmoduleslots

Supportsamaximumof384GigabitEthernetportsor3841/10GbEportsor12840GbEportsor32100GbEports,oracombination

Additional ports and slots 2MPU(formanagementmodules)slots

4switchfabricslots

2MPU(formanagementmodules)slots

4switchfabricslots

2MPU(formanagementmodules)slots

9switchfabricslots

Physical characteristics

Dimensions

Weight

Fullconfigurationweight

17.4(w)x27.87(d)x17.4(h)in(44.2x70.8x44.2cm)(10Uheight)

132.28lb(60kg)

220.46lb(100kg)

17.4(w)x27.87(d)x17.4(h)in(44.2x70.8x44.2cm)

132.28lb(60kg)

220.46lb(100kg)

17.4(w)x29.13(d)x38.39(h)in(44.2x73.99x97.51cm)(22Uheight)

209.44lb(95kg)

374.78lb(170kg)

Memory and processor

Gigabitmodule

10Gmodule

Managementmodule

Fabric

PowerPC@667MHz,1GBRAM;packetbuffersize:512MB(Ingress,sharedby241-GbEports)

PowerPC@667MHz,1GBRAM;packetbuffersize:512MB(Ingress/sharedby210GbEports)

QuadCoreCPU@1800MHz,512MBflash,4GBcompactflash,8GBRAM

PowerPC@400MHz,128MBRAM

PowerPC@667MHz,1GBRAM;packetbuffersize:512MB(Ingress,sharedby241-GbEports)

PowerPC@667MHz,1GBRAM;packetbuffersize:512MB(Ingress/sharedby210GbEports)

QuadCoreCPU@1800MHz,512MBflash,4GBcompactflash,8GBRAM

PowerPC@400MHz,128MBRAM

PowerPC@667MHz,1GBRAM;packetbuffersize:512MB(Ingress,sharedby241-GbEports)

PowerPC@667MHz,1GBRAM;packetbuffersize:512MB(Ingress/sharedby210GbEports)

QuadCoreCPU@1800MHz,512MBflash,4GBcompactflash,8GBRAM

PowerPC@400MHz,128MBRAM

Mounting and enclosure MountsinanEIA-standard19in.telcorackorequipmentcabinet

MountsinanEIA-standard19in.telcorackorequipmentcabinet

MountsinanEIA-standard19in.telcorackorequipmentcabinet

Performance

Throughput

Routing/Switchingcapacity

1920Mpps

3240Gb/s

1920Mpps

3240Gb/s

3840Mpps

6120Gb/s

Environment

Operatingtemperature

Operatingrelativehumidity

Nonoperating/Storagetemperature

Nonoperating/Storagerelativehumidity

32°Fto104°F(0°Cto40°C)

5%to95%,noncondensing

-40°Fto158°F(-40°Cto70°C)

5%to95%,noncondensing

32°Fto104°F(0°Cto40°C)

5%to95%,noncondensing

-40°Fto158°F(-40°Cto70°C)

5%to95%,noncondensing

32°Fto104°F(0°Cto40°C)

5%to95%,noncondensing

-40°Fto158°F(-40°Cto70°C)

5%to95%,noncondensing

HP 12500 Switch Series

Specifications

12

Data sheet | HP 12500 Switch Series

HP 12504 AC Switch Chassis (JC654A) HP 12504 DC Switch Chassis (JC655A) HP 12508 AC Switch Chassis (JF431C)

Electrical characteristics

Frequency

Description

Maximumheatdissipation

ACvoltage

DCvoltage

Maximumpowerrating

50/60Hz

8123BTU/hr(8569.77kJ/hr)

100-120/200-240VAC

2380W

NotesMaximumpowerratingandmaximumheatdissipationaretheworst-casetheoreticalmaximumnumbersprovidedforplanningtheinfrastructurewithfullyloadedPoE(ifequipped),100%traffic,allportspluggedin,andallmodulespopulated.

8123BTU/hr(8569.77kJ/hr)

-48to-60VDC

2380W

Maximumpowerratingandmaximumheatdissipationaretheworst-casetheoreticalmaximumnumbersprovidedforplanningtheinfrastructurewithfullyloadedPoE(ifequipped),100%traffic,allportspluggedin,andallmodulespopulated.

50/60HzAchievedMiercomCertifiedGreenAward

10GbEmodulesconsumehalfthepowercomparedtocompetitiveproducts;redundant,scalable,90%efficientpowersuppliesdeliverhighreliabilityinthedatacenter;newASICtechnologyhaslowpowerconsumptionwhenprovidingrichfeatures.

14587BTU/hr(15389.29kJ/hr)

100-120/200-240VAC

4750W

Maximumpowerratingandmaximumheatdissipationaretheworst-casetheoreticalmaximumnumbersprovidedforplanningtheinfrastructurewithfullyloadedPoE(ifequipped),100%traffic,allportspluggedin,andallmodulespopulated.

Safety CELabeled;cULCertified;ULListed;EN60825-1SafetyofLaserProducts-Part1;EN60825-2SafetyofLaserProducts-Part2;IEC60825;IEC60950-1:2001(withCBReport);CAN/CSA-C22.2No.60950-1-03;Anatel;ULAR;GOST;EN60950-1/A11;FDA21CFRSubchapterJ;NOM;UL60950-1:2003;EN60950-1:2001;ROHSCompliance

CELabeled;cULCertified;ULListed;EN60825-1SafetyofLaserProducts-Part1;EN60825-2SafetyofLaserProducts-Part2;IEC60825;IEC60950-1:2001(withCBReport);CAN/CSA-C22.2No.60950-1-03;Anatel;ULAR;GOST;EN60950-1/A11;FDA21CFRSubchapterJ;NOM;UL60950-1:2003;EN60950-1:2001;ROHSCompliance

CELabeled;cULCertified;ULListed;EN60825-1SafetyofLaserProducts-Part1;EN60825-2SafetyofLaserProducts-Part2;IEC60825;IEC60950-1:2001(withCBReport);CAN/CSA-C22.2No.60950-1-03;Anatel;ULAR;GOST;EN60950-1/A11;FDA21CFRSubchapterJ;NOM;UL60950-1:2003;EN60950-1:2001;ROHSCompliance

Emissions VCCIClassA;EN55022ClassA;VCCIV-3/2000.04;ICES-003ClassA;AS/NZSCISPR22ClassA;EMCDirective2004/108/EC;FCC(CFR47,Part15)ClassA

VCCIClassA;EN55022ClassA;VCCIV-3/2000.04;ICES-003ClassA;AS/NZSCISPR22ClassA;EMCDirective2004/108/EC;FCC(CFR47,Part15)ClassA

VCCIClassA;EN55022ClassA;VCCIV-3/2000.04;ICES-003ClassA;AS/NZSCISPR22ClassA;EMCDirective2004/108/EC;FCC(CFR47,Part15)ClassA

13

Data sheet | HP 12500 Switch Series

HP 12504 AC Switch Chassis (JC654A) HP 12504 DC Switch Chassis (JC655A) HP 12508 AC Switch Chassis (JF431C)

Immunity

Generic

EN

ESD

Radiated

EFT/Burst

Surge

Conducted

Powerfrequencymagneticfield

Voltagedipsandinterruptions

Harmonics

Flicker

ETSIEN300386V1.3.3

EN55024:1998+A1:2001+A2:2003

EN61000-4-2;IEC61000-4-2

EN61000-4-3;IEC61000-4-3

EN61000-4-4;IEC61000-4-4

EN61000-4-5;IEC61000-4-5

EN61000-4-6;IEC61000-4-6

IEC61000-4-8;EN61000-4-8

EN61000-4-11;IEC61000-4-11

EN61000-3-2,IEC61000-3-2

EN61000-3-3,IEC61000-3-3

ETSIEN300386V1.3.3

EN55024:1998+A1:2001+A2:2003

EN61000-4-2;IEC61000-4-2

EN61000-4-3;IEC61000-4-3

EN61000-4-4;IEC61000-4-4

EN61000-4-5;IEC61000-4-5

EN61000-4-6;IEC61000-4-6

IEC61000-4-8;EN61000-4-8

EN61000-4-11;IEC61000-4-11

EN61000-3-2,IEC61000-3-2

EN61000-3-3,IEC61000-3-3

ETSIEN300386V1.3.3

EN55024:1998+A1:2001+A2:2003

EN61000-4-2;IEC61000-4-2

EN61000-4-3;IEC61000-4-3

EN61000-4-4;IEC61000-4-4

EN61000-4-5;IEC61000-4-5

EN61000-4-6;IEC61000-4-6

IEC61000-4-8;EN61000-4-8

EN61000-4-11;IEC61000-4-11

EN61000-3-2,IEC61000-3-2

EN61000-3-3,IEC61000-3-3

Management IMC—IntelligentManagementCenter;command-lineinterface;out-of-bandmanagement(serialRS-232C);SNMPManager;Telnet;RMON1;FTP;in-lineandout-of-band;terminalinterface(serialRS-232C);modeminterface

IMC—IntelligentManagementCenter;command-lineinterface;out-of-bandmanagement(serialRS-232C);SNMPManager;Telnet;RMON1;FTP;in-lineandout-of-band;terminalinterface(serialRS-232C);modeminterface

IMC—IntelligentManagementCenter;command-lineinterface;out-of-bandmanagement(serialRS-232C);SNMPManager;Telnet;RMON1;FTP;in-lineandout-of-band;terminalinterface(serialRS-232C);modeminterface

Services RefertotheHPwebsiteathp.com/networking/servicesfordetailsontheservice-leveldescriptionsandproductnumbers.Fordetailsaboutservicesandresponsetimesinyourarea,pleasecontactyourlocalHPsalesoffice.

RefertotheHPwebsiteathp.com/networking/servicesfordetailsontheservice-leveldescriptionsandproductnumbers.Fordetailsaboutservicesandresponsetimesinyourarea,pleasecontactyourlocalHPsalesoffice.

RefertotheHPwebsiteathp.com/networking/servicesfordetailsontheservice-leveldescriptionsandproductnumbers.Fordetailsaboutservicesandresponsetimesinyourarea,pleasecontactyourlocalHPsalesoffice.

14

Data sheet | HP 12500 Switch Series

HP 12508 DC Switch Chassis (JC652A) HP 12518 AC Switch Chassis (JF430C) HP 12518 DC Switch Chassis (JC653A)

I/O ports and slots 8openmoduleslots

Supportsamaximumof384GigabitEthernetportsor3841/10GbEportsor12840GbEportsor32100GbEports,oracombination

18openmoduleslots

Supportsamaximumof864GigabitEthernetportsor8641/10GbEportsor28840GbEportsor72100GbEports,oracombination

18openmoduleslots

Supportsamaximumof864GigabitEthernetportsor8641/10GbEportsor28840GbEportsor72100GbEports,oracombination

Additional ports and slots 2MPU(formanagementmodules)slots

9switchfabricslots

2MPU(formanagementmodules)slots

9switchfabricslots

2MPU(formanagementmodules)slots

9switchfabricslots

Physical characteristics

Dimensions

Weight

Fullconfigurationweight

17.4(w)x29.13(d)x38.39(h)in(44.2x73.99x97.51cm)(22Uheight)

209.44lb(95kg)

374.78lb(170kg)

17.4(w)x29.13(d)x66.38(h)in(44.2x73.99x168.61cm)(38Uheight)

352.74lb(160kg)

639.33lb(290kg)

17.4(w)x29.13(d)x66.38(h)in(44.2x73.99x168.61cm)(38Uheight)

352.74lb(160kg)

639.33lb(290kg)

Memory and processor

Gigabitmodule

10Gmodule

Managementmodule

Fabric

PowerPC@667MHz,1GBRAM;packetbuffersize:512MB(Ingress,sharedby241-GbEports)

PowerPC@667MHz,1GBRAM;packetbuffersize:512MB(Ingress/sharedby210GbEports)

QuadCoreCPU@1800MHz,512MBflash,4GBcompactflash,8GBRAM

PowerPC@400MHz,128MBRAM

PowerPC@667MHz,1GBRAM;packetbuffersize:512MB(Ingress,sharedby241-GbEports)

PowerPC@667MHz,1GBRAM;packetbuffersize:512MB(Ingress/sharedby210GbEports)

QuadCoreCPU@1800MHz,512MBflash,4GBcompactflash,8GBRAM

PowerPC@400MHz,128MBRAM

PowerPC@667MHz,1GBRAM;packetbuffersize:512MB(Ingress,sharedby241-GbEports)

PowerPC@667MHz,1GBRAM;packetbuffersize:512MB(Ingress/sharedby210GbEports)

QuadCoreCPU@1800MHz,512MBflash,4GBcompactflash,8GBRAM

PowerPC@400MHz,128MBRAM

Mounting and enclosure MountsinanEIA-standard19in.telcorackorequipmentcabinet

MountsinanEIA-standard19in.telcorackorequipmentcabinet

MountsinanEIA-standard19in.telcorackorequipmentcabinet

Performance

Throughput

Routing/Switchingcapacity

3840Mpps

6120Gb/s

8640Mpps

13.3Tb/s

8640Mpps

13.3Tb/s

HP 12500 Switch Series

Specifications (continued)

15

Data sheet | HP 12500 Switch Series

HP 12508 DC Switch Chassis (JC652A) HP 12518 AC Switch Chassis (JF430C) HP 12518 DC Switch Chassis (JC653A)

Environment

Operatingtemperature

Operatingrelativehumidity

Nonoperating/Storagetemperature

Nonoperating/Storagerelativehumidity

32°Fto104°F(0°Cto40°C)

5%to95%,noncondensing

-40°Fto158°F(-40°Cto70°C)

5%to95%,noncondensing

32°Fto104°F(0°Cto40°C)

5%to95%,noncondensing

-40°Fto158°F(-40°Cto70°C)

5%to95%,noncondensing

32°Fto104°F(0°Cto40°C)

5%to95%,noncondensing

-40°Fto158°F(-40°Cto70°C)

5%to95%,noncondensing

Electrical characteristics

Frequency

Maximumheatdissipation

ACvoltage

DCvoltage

Maximumpowerrating

14587BTU/hr(15389.29kJ/hr)

-48to-60VDC

4750W

NotesMaximumpowerratingandmaximumheatdissipationaretheworst-casetheoreticalmaximumnumbersprovidedforplanningtheinfrastructurewithfullyloadedPoE(ifequipped),100%traffic,allportspluggedin,andallmodulespopulated.

50/60Hz

32859BTU/hr(34666.24kJ/hr)

100-120/200-240VAC

10700W

Maximumpowerratingandmaximumheatdissipationaretheworst-casetheoreticalmaximumnumbersprovidedforplanningtheinfrastructurewithfullyloadedPoE(ifequipped),100%traffic,allportspluggedin,andallmodulespopulated.

32859BTU/hr(34666.24kJ/hr)

-48to-60VDC

10700W

Maximumpowerratingandmaximumheatdissipationaretheworst-casetheoreticalmaximumnumbersprovidedforplanningtheinfrastructurewithfullyloadedPoE(ifequipped),100%traffic,allportspluggedin,andallmodulespopulated.

Safety CELabeled;cULCertified;ULListed;EN60825-1SafetyofLaserProducts-Part1;EN60825-2SafetyofLaserProducts-Part2;IEC60825;IEC60950-1:2001(withCBReport);CAN/CSA-C22.2No.60950-1-03;Anatel;ULAR;GOST;EN60950-1/A11;FDA21CFRSubchapterJ;NOM;UL60950-1:2003;EN60950-1:2001;ROHSCompliance

CELabeled;cULCertified;ULListed;EN60825-1SafetyofLaserProducts-Part1;EN60825-2SafetyofLaserProducts-Part2;IEC60825;IEC60950-1:2001(withCBReport);CAN/CSA-C22.2No.60950-1-03;Anatel;ULAR;GOST;EN60950-1/A11;FDA21CFRSubchapterJ;NOM;UL60950-1:2003;EN60950-1:2001;ROHSCompliance

CELabeled;cULCertified;ULListed;EN60825-1SafetyofLaserProducts-Part1;EN60825-2SafetyofLaserProducts-Part2;IEC60825;IEC60950-1:2001(withCBReport);CAN/CSA-C22.2No.60950-1-03;Anatel;ULAR;GOST;EN60950-1/A11;FDA21CFRSubchapterJ;NOM;UL60950-1:2003;EN60950-1:2001;ROHSCompliance

Emissions VCCIClassA;EN55022ClassA;VCCIV-3/2000.04;ICES-003ClassA;AS/NZSCISPR22ClassA;EMCDirective2004/108/EC;FCC(CFR47,Part15)ClassA

VCCIClassA;EN55022ClassA;VCCIV-3/2000.04;ICES-003ClassA;AS/NZSCISPR22ClassA;EMCDirective2004/108/EC;FCC(CFR47,Part15)ClassA

VCCIClassA;EN55022ClassA;VCCIV-3/2000.04;ICES-003ClassA;AS/NZSCISPR22ClassA;EMCDirective2004/108/EC;FCC(CFR47,Part15)ClassA

16

Data sheet | HP 12500 Switch Series

HP 12508 DC Switch Chassis (JC652A) HP 12518 AC Switch Chassis (JF430C) HP 12518 DC Switch Chassis (JC653A)

Immunity

Generic

EN

ESD

Radiated

EFT/Burst

Surge

Conducted

Powerfrequencymagneticfield

Voltagedipsandinterruptions

Harmonics

Flicker

ETSIEN300386V1.3.3

EN55024:1998+A1:2001+A2:2003

EN61000-4-2;IEC61000-4-2

EN61000-4-3;IEC61000-4-3

EN61000-4-4;IEC61000-4-4

EN61000-4-5;IEC61000-4-5

EN61000-4-6;IEC61000-4-6

IEC61000-4-8;EN61000-4-8

EN61000-4-11;IEC61000-4-11

EN61000-3-2,IEC61000-3-2

EN61000-3-3,IEC61000-3-3

ETSIEN300386V1.3.3

EN55024:1998+A1:2001+A2:2003

EN61000-4-2;IEC61000-4-2

EN61000-4-3;IEC61000-4-3

EN61000-4-4;IEC61000-4-4

EN61000-4-5;IEC61000-4-5

EN61000-4-6;IEC61000-4-6

IEC61000-4-8;EN61000-4-8

EN61000-4-11;IEC61000-4-11

EN61000-3-2,IEC61000-3-2

EN61000-3-3,IEC61000-3-3

ETSIEN300386V1.3.3

EN55024:1998+A1:2001+A2:2003

EN61000-4-2;IEC61000-4-2

EN61000-4-3;IEC61000-4-3

EN61000-4-4;IEC61000-4-4

EN61000-4-5;IEC61000-4-5

EN61000-4-6;IEC61000-4-6

IEC61000-4-8;EN61000-4-8

EN61000-4-11;IEC61000-4-11

EN61000-3-2,IEC61000-3-2

EN61000-3-3,IEC61000-3-3

Management IMC—IntelligentManagementCenter;command-lineinterface;out-of-bandmanagement(serialRS-232C);

SNMPManager;Telnet;RMON1;FTP;in-lineandout-of-band;terminalinterface(serialRS-232C);modeminterface

IMC—IntelligentManagementCenter;command-lineinterface;out-of-bandmanagement(serialRS-232C);

SNMPManager;Telnet;RMON1;FTP;in-lineandout-of-band;terminalinterface(serialRS-232C);modeminterface

IMC—IntelligentManagementCenter;command-lineinterface;out-of-bandmanagement(serialRS-232C);

SNMPManager;Telnet;RMON1;FTP;in-lineandout-of-band;terminalinterface(serialRS-232C);modeminterface

Services RefertotheHPwebsiteathp.com/networking/servicesfordetailsontheservice-leveldescriptionsandproductnumbers.Fordetailsaboutservicesandresponsetimesinyourarea,pleasecontactyourlocalHPsalesoffice.

RefertotheHPwebsiteathp.com/networking/servicesfordetailsontheservice-leveldescriptionsandproductnumbers.Fordetailsaboutservicesandresponsetimesinyourarea,pleasecontactyourlocalHPsalesoffice.

RefertotheHPwebsiteathp.com/networking/servicesfordetailsontheservice-leveldescriptionsandproductnumbers.Fordetailsaboutservicesandresponsetimesinyourarea,pleasecontactyourlocalHPsalesoffice.

17

Data sheet | HP 12500 Switch Series

HP FlexFabric 12508E AC Switch Chassis (JG782A) HP FlexFabric 12508E DC Switch Chassis (JG783A)

I/O ports and slots 8openmoduleslots

Supportsamaximumof384GigabitEthernetportsor3841/10GbEportsor12840GbEportsor32100GbEports,oracombination

8openmoduleslots

Supportsamaximumof384GigabitEthernetportsor3841/10GbEportsor12840GbEportsor32100GbEports,oracombination

Additional ports and slots 2MPU(formanagementmodules)slots

9switchfabricslots

2MPU(formanagementmodules)slots

9switchfabricslots

Physical characteristics

Dimensions

Weight

Fullconfigurationweight

17.4(w)x29.13(d)x38.39(h)in(44.2x74.0x97.51cm)(22Uheight)

242.51lb(110kg)

374.78lb(170kg)

17.4(w)x29.13(d)x38.39(h)in(44.2x73.99x97.51cm)(22Uheight)

209.44lb(95kg)

374.78lb(170kg)

Memory and processor

Gigabitmodule

10Gmodule

Managementmodule

Fabric

PowerPC@667,1GBRAM;packetbuffersize:512MB(Ingress,sharedby241-GbEports)

PowerPC@667MHz,1GBRAM;packetbuffersize:512MB(Ingress,sharedby241-GbEports)

QuadCoreCPU@1800MHz,512MBflash,4GBcompactflash,8GBRAM

PowerPC@400MHz,128MBRAM

PowerPC@667MHz,1GBRAM;packetbuffersize:512MB(Ingress,sharedby241-GbEports)

PowerPC@667MHz,1GBRAM;packetbuffersize:512MB(Ingress/sharedby210GbEports)

QuadCoreCPU@1800MHz,512MBflash,4GBcompactflash,8GBRAM

PowerPC@400MHz,128MBRAM

Mounting and enclosure MountsinanEIA-standard19in.telcorackorequipmentcabinet MountsinanEIA-standard19in.telcorackorequipmentcabinet

Performance

Throughput

Routing/Switchingcapacity

4800Mpps

10.8Tb/s

4800Mpps

10.8Tb/s

HP 12500 Switch Series

Specifications (continued)

18

Data sheet | HP 12500 Switch Series

HP FlexFabric 12508E AC Switch Chassis (JG782A) HP FlexFabric 12508E DC Switch Chassis (JG783A)

Environment

Operatingtemperature

Operatingrelativehumidity

Nonoperating/Storagetemperature

Nonoperating/Storagerelativehumidity

32°Fto104°F(0°Cto40°C)

5%to95%,noncondensing

-40°Fto158°F(-40°Cto70°C)

5%to95%,noncondensing

32°Fto104°F(0°Cto40°C)

5%to95%,noncondensing

-40°Fto158°F(-40°Cto70°C)

5%to95%,noncondensing

Electrical characteristics

Frequency

Description

Maximumheatdissipation

ACvoltage

DCvoltage

Maximumpowerrating

50/60Hz

AchievedMiercomCertifiedGreenAward

10GbEmodulesconsumehalfthepowercomparedtocompetitiveproducts;redundant,scalable,90%efficientpowersuppliesdeliverhighreliabilityinthedatacenter;newASICtechnologyhaslowpowerconsumptionwhenprovidingrichfeatures.

14587BTU/hr(15389.29kJ/hr)

100-120/200-240VAC

4750W

NotesMaximumpowerratingandmaximumheatdissipationaretheworst-casetheoreticalmaximumnumbersprovidedforplanningtheinfrastructurewithfullyloadedPoE(ifequipped),100%traffic,allportspluggedin,andallmodulespopulated.

14587BTU/hr(15389.29kJ/hr)

-48to-60VDC

4750W

Maximumpowerratingandmaximumheatdissipationaretheworst-casetheoreticalmaximumnumbersprovidedforplanningtheinfrastructurewithfullyloadedPoE(ifequipped),100%traffic,allportspluggedin,andallmodulespopulated.

Safety CELabeled;cULCertified;ULListed;EN60825-1SafetyofLaserProducts-Part1;EN60825-2SafetyofLaserProducts-Part2;IEC60825;IEC60950-1:2001(withCBReport);CAN/CSA-C22.2No.60950-1-03;Anatel;ULAR;GOST;EN60950-1/A11;FDA21CFRSubchapterJ;NOM;UL60950-1:2003;EN60950-1:2001;ROHSCompliance

CELabeled;cULCertified;ULListed;EN60825-1SafetyofLaserProducts-Part1;EN60825-2SafetyofLaserProducts-Part2;IEC60825;IEC60950-1:2001(withCBReport);CAN/CSA-C22.2No.60950-1-03;Anatel;ULAR;GOST;EN60950-1/A11;FDA21CFRSubchapterJ;NOM;UL60950-1:2003;EN60950-1:2001;ROHSCompliance

19

Data sheet | HP 12500 Switch Series

HP FlexFabric 12508E AC Switch Chassis (JG782A) HP FlexFabric 12508E DC Switch Chassis (JG783A)

Emissions VCCIClassA;EN55022ClassA;VCCIV-3/2000.04;ICES-003ClassA;AS/NZSCISPR22ClassA;EMCDirective2004/108/EC;FCC(CFR47,Part15)ClassA

VCCIClassA;EN55022ClassA;VCCIV-3/2000.04;ICES-003ClassA;AS/NZSCISPR22ClassA;EMCDirective2004/108/EC;FCC(CFR47,Part15)ClassA

Immunity

Generic

EN

ESD

Radiated

EFT/Burst

Surge

Conducted

Powerfrequencymagneticfield

Voltagedipsandinterruptions

Harmonics

Flicker

ETSIEN300386V1.3.3

EN55024:1998+A1:2001+A2:2003

EN61000-4-2;IEC61000-4-2

EN61000-4-3;IEC61000-4-3

EN61000-4-4;IEC61000-4-4

EN61000-4-5;IEC61000-4-5

EN61000-4-6;IEC61000-4-6

IEC61000-4-8;EN61000-4-8

EN61000-4-11;IEC61000-4-11

EN61000-3-2,IEC61000-3-2

EN61000-3-3,IEC61000-3-3

ETSIEN300386V1.3.3

EN55024:1998+A1:2001+A2:2003

EN61000-4-2;IEC61000-4-2

EN61000-4-3;IEC61000-4-3

EN61000-4-4;IEC61000-4-4

EN61000-4-5;IEC61000-4-5

EN61000-4-6;IEC61000-4-6

IEC61000-4-8;EN61000-4-8

EN61000-4-11;IEC61000-4-11

EN61000-3-2,IEC61000-3-2

EN61000-3-3,IEC61000-3-3

Management IMC-IntelligentManagementCenter;command-lineinterface;out-of-bandmanagement(serialRS-232C);SNMPManager;Telnet;RMON1;FTP;in-lineandout-of-band;terminalinterface(serialRS-232C);modeminterface

IMC-IntelligentManagementCenter;command-lineinterface;out-of-bandmanagement(serialRS-232C);SNMPManager;Telnet;RMON1;FTP;in-lineandout-of-band;terminalinterface(serialRS-232C);modeminterface

Services RefertotheHPwebsiteathp.com/networking/servicesfordetailsontheservice-leveldescriptionsandproductnumbers.Fordetailsaboutservicesandresponsetimesinyourarea,pleasecontactyourlocalHPsalesoffice.

RefertotheHPwebsiteathp.com/networking/servicesfordetailsontheservice-leveldescriptionsandproductnumbers.Fordetailsaboutservicesandresponsetimesinyourarea,pleasecontactyourlocalHPsalesoffice.

20

Data sheet | HP 12500 Switch Series

HP FlexFabric 12518E AC Switch Chassis (JG784A) HP FlexFabric 12518E DC Switch Chassis (JG785A)

I/O ports and slots 18openmoduleslots

Supportsamaximumof864GigabitEthernetportsor8641/10GbEportsor28840GbEportsor72100GbEports,oracombination

18openmoduleslots

Supportsamaximumof864GigabitEthernetportsor8641/10GbEportsor28840GbEportsor72100GbEports,oracombination

Additional ports and slots 2MPU(formanagementmodules)slots

9switchfabricslots

2MPU(formanagementmodules)slots

9switchfabricslots

Physical characteristics

Dimensions

Weight

Fullconfigurationweight

17.4(w)x29.13(d)x66.38(h)in(44.2x73.99x168.61cm)(38Uheight)

352.74lb(160kg)

639.33lb(290kg)

17.4(w)x29.13(d)x66.38(h)in(44.2x73.99x168.61cm)(38Uheight)

352.74lb(160kg)

639.33lb(290kg)

Memory and processor

Gigabitmodule

10Gmodule

Managementmodule

Fabric

PowerPC@667MHz,1GBRAM;packetbuffersize:512MB(Ingress,sharedby241-GbEports)

PowerPC@667MHz,1GBRAM;packetbuffersize:512MB(Ingress/sharedby210GbEports)

QuadCoreCPU@1800MHz,512MBflash,4GBcompactflash,8GBRAM

PowerPC@400MHz,128MBRAM

PowerPC@667MHz,1GBRAM;packetbuffersize:512MB(Ingress,sharedby241-GbEports)

PowerPC@667MHz,1GBRAM;packetbuffersize:512MB(Ingress/sharedby210GbEports)

QuadCoreCPU@1800MHz,512MBflash,4GBcompactflash,8GBRAM

PowerPC@400MHz,128MBRAM

Mounting and enclosure MountsinanEIA-standard19in.telcorackorequipmentcabinet MountsinanEIA-standard19in.telcorackorequipmentcabinet

Performance

Throughput

Routing/Switchingcapacity

10.8Bpps

24.3Tb/s

10.8Bpps

24.3Tb/s

Environment

Operatingtemperature

Operatingrelativehumidity

Nonoperating/Storagetemperature

Nonoperating/Storagerelativehumidity

32°Fto104°F(0°Cto40°C)

5%to95%,noncondensing

-40°Fto158°F(-40°Cto70°C)

5%to95%,noncondensing

32°Fto104°F(0°Cto40°C)

5%to95%,noncondensing

-40°Fto158°F(-40°Cto70°C)

5%to95%,noncondensing

HP 12500 Switch Series

Specifications (continued)

21

Data sheet | HP 12500 Switch Series

HP FlexFabric 12518E AC Switch Chassis (JG784A) HP FlexFabric 12518E DC Switch Chassis (JG785A)

Electrical characteristics

Frequency

Maximumheatdissipation

ACvoltage

DCvoltage

Maximumpowerrating

50/60Hz

32859BTU/hr(34666.24kJ/hr)

100-120/200-240VAC

10700W

NotesMaximumpowerratingandmaximumheatdissipationaretheworst-casetheoreticalmaximumnumbersprovidedforplanningtheinfrastructurewithfullyloadedPoE(ifequipped),100%traffic,allportspluggedin,andallmodulespopulated.

32859BTU/hr(34666.24kJ/hr)

-48to-60VDC

10700W

Maximumpowerratingandmaximumheatdissipationaretheworst-casetheoreticalmaximumnumbersprovidedforplanningtheinfrastructurewithfullyloadedPoE(ifequipped),100%traffic,allportspluggedin,andallmodulespopulated.

Safety CELabeled;cULCertified;ULListed;EN60825-1SafetyofLaserProducts-Part1;EN60825-2SafetyofLaserProducts-Part2;IEC60825;IEC60950-1:2001(withCBReport);CAN/CSA-C22.2No.60950-1-03;Anatel;ULAR;GOST;EN60950-1/A11;FDA21CFRSubchapterJ;NOM;UL60950-1:2003;EN60950-1:2001;ROHSCompliance

CELabeled;cULCertified;ULListed;EN60825-1SafetyofLaserProducts-Part1;EN60825-2SafetyofLaserProducts-Part2;IEC60825;IEC60950-1:2001(withCBReport);CAN/CSA-C22.2No.60950-1-03;Anatel;ULAR;GOST;EN60950-1/A11;FDA21CFRSubchapterJ;NOM;UL60950-1:2003;EN60950-1:2001;ROHSCompliance

Emissions VCCIClassA;EN55022ClassA;VCCIV-3/2000.04;ICES-003ClassA;AS/NZSCISPR22ClassA;EMCDirective2004/108/EC;FCC(CFR47,Part15)ClassA

VCCIClassA;EN55022ClassA;VCCIV-3/2000.04;ICES-003ClassA;AS/NZSCISPR22ClassA;EMCDirective2004/108/EC;FCC(CFR47,Part15)ClassA

Immunity

Generic

EN

ESD

Radiated

EFT/Burst

Surge

Conducted

Powerfrequencymagneticfield

Voltagedipsandinterruptions

Harmonics

Flicker

ETSIEN300386V1.3.3

EN55024:1998+A1:2001+A2:2003

EN61000-4-2;IEC61000-4-2

EN61000-4-3;IEC61000-4-3

EN61000-4-4;IEC61000-4-4

EN61000-4-5;IEC61000-4-5

EN61000-4-6;IEC61000-4-6

IEC61000-4-8;EN61000-4-8

EN61000-4-11;IEC61000-4-11

EN61000-3-2,IEC61000-3-2

EN61000-3-3,IEC61000-3-3

ETSIEN300386V1.3.3

EN55024:1998+A1:2001+A2:2003

EN61000-4-2;IEC61000-4-2

EN61000-4-3;IEC61000-4-3

EN61000-4-4;IEC61000-4-4

EN61000-4-5;IEC61000-4-5

EN61000-4-6;IEC61000-4-6

IEC61000-4-8;EN61000-4-8

EN61000-4-11;IEC61000-4-11

EN61000-3-2,IEC61000-3-2

EN61000-3-3,IEC61000-3-3

Management IMC—IntelligentManagementCenter;command-lineinterface;out-of-bandmanagement(serialRS-232C);SNMPManager;Telnet;RMON1;FTP;in-lineandout-of-band;terminalinterface(serialRS-232C);modeminterface

IMC—IntelligentManagementCenter;command-lineinterface;out-of-bandmanagement(serialRS-232C);SNMPManager;Telnet;RMON1;FTP;in-lineandout-of-band;terminalinterface(serialRS-232C);modeminterface

Services RefertotheHPwebsiteathp.com/networking/servicesfordetailsontheservice-leveldescriptionsandproductnumbers.Fordetailsaboutservicesandresponsetimesinyourarea,pleasecontactyourlocalHPsalesoffice.

RefertotheHPwebsiteathp.com/networking/servicesfordetailsontheservice-leveldescriptionsandproductnumbers.Fordetailsaboutservicesandresponsetimesinyourarea,pleasecontactyourlocalHPsalesoffice.

22

Data sheet | HP 12500 Switch Series

Standards and Protocols

(appliestoallproductsinseries)

BGP RFC1657DefinitionsofManagedObjectsforBGPv4

RFC1771BGPv4

RFC1772ApplicationoftheBGP

RFC1773ExperiencewiththeBGP-4Protocol

RFC1774BGP-4ProtocolAnalysis

RFC1997BGPCommunitiesAttribute

RFC1998PPPGandalfFZACompressionProtocol

RFC2385BGPSessionProtectionviaTCPMD5

RFC2439BGPRouteFlapDamping

RFC2796BGPRouteReflection

RFC2842CapabilityAdvertisementwithBGP-4

RFC2858BGP-4Multi-ProtocolExtensions

RFC2918RouteRefreshCapability

Denial of service protection RFC2267NetworkIngressFiltering AutomaticFilteringofwellknownDenialofServicePackets

CPUDoSProtection

RateLimitingbyACLs

Device management RFC1155StructureandMgmtInformation(SMIv1)

RFC1157SNMPv1/v2c

RFC1305NTPv3

RFC1945HypertextTransferProtocol—HTTP/1.0

RFC2452MIBforTCP6

RFC2454MIBforUDP6

RFC2573(SNMPv3Applications)

RFC2578-2580SMIv2

RFC2579(SMIv2TextConventions)

RFC2580(SMIv2Conformance)

RFC2819(RMONgroupsAlarm,Event,HistoryandStatisticsonly)

RFC2819RMON

RFC3417(SNMPTransportMappings)SNMPv3andRMON

RFCsupportSSHv1/SSHv2SecureShellTACACS/TACACS+

General protocols IEEE802.1adQ-in-Q

IEEE802.1agServiceLayerOAM

IEEE802.1ahProviderBackboneBridges

IEEE802.1DMACBridges

IEEE802.1pPriorityIEEE802.1QVLANs

IEEE802.1sMultipleSpanningTrees

IEEE802.1vVLANclassificationbyProtocolandPort

IEEE802.1wRapidReconfigurationofSpanningTree

IEEE802.1XPAE

IEEE802.3ab1000BASE-T

IEEE802.3adLinkAggregation(LAG)

IEEE802.3ae10-GigabitEthernet

IEEE802.3ahEthernetinFirstMileoverPointtoPointFiber-EFMF

IEEE802.3ba40and100GigabitEthernetArchitecture

IEEE802.3i10BASE-T

IEEE802.3u100BASE-X

IEEE802.3xFlowControl

IEEE802.3z1000BASE-X

RFC768UDP

RFC783TFTPProtocol(revision2)

RFC791IP

RFC792ICMP

RFC793TCP

RFC826ARP

RFC854TELNET

RFC868TimeProtocol

RFC903RARP

RFC951BOOTP

RFC959FileTransferProtocol(FTP)

RFC1027ProxyARP

RFC1042IPDatagrams

RFC1350TFTPProtocol(revision2)

RFC1519CIDR

RFC1542BOOTPExtensions

RFC1812IPv4Routing

RFC2131DHCP

RFC2338VRRP

RFC2784GenericRoutingEncapsulation(GRE)

RFC2865RemoteAuthenticationDialInUserService(RADIUS)

IP multicast RFC1112IGMP

RFC2236IGMPv2

RFC2283MultiprotocolExtensionsforBGP-4

RFC2362PIMSparseMode

RFC2934ProtocolIndependentMulticastMIBforIPv4

RFC3376IGMPv3

RFC3618MulticastSourceDiscoveryProtocol(MSDP)

RFC4601PIMSparseMode

23

Data sheet | HP 12500 Switch Series

Standards and Protocols

(appliestoallproductsinseries)

IPv6 RFC1350TFTP

RFC1981IPv6PathMTUDiscovery

RFC2080RIPngforIPv6

RFC2460IPv6Specification

RFC2461IPv6NeighborDiscovery

RFC2462IPv6StatelessAddressAuto-configuration

RFC2463ICMPv6

RFC2473GenericPacketTunnelinginIPv6

RFC2475IPv6DiffServArchitecture

RFC2529TransmissionofIPv6PacketsoverIPv4

RFC2710MulticastListenerDiscovery(MLD)forIPv6

RFC2740OSPFv3forIPv6

RFC2893TransitionMechanismsforIPv6HostsandRouters

RFC2925DefinitionsofManagedObjectsforRemotePing,Traceroute,andLookupOperations(Pingonly)

RFC3315DHCPv6(clientonly)

RFC3484DefaultAddressSelectionforIPv6RFC3513IPv6AddressingArchitecture

RFC3587IPv6GlobalUnicastAddressFormat

RFC3810MulticastListenerDiscoveryVersion2(MLDv2)forIPv6

RFC4251SSHv6Architecture

RFC4252SSHv6Authentication

RFC4253SSHv6TransportLayer

RFC4254SSHv6Connection

RFC4541IGMP&MLDSnoopingSwitch

RFC4862IPv6StatelessAddressAuto-configuration

MIBs IEEE8023-LAG-MIB

RFC1213MIBII

RFC1229InterfaceMIBExtensions

RFC1286BridgeMIB

RFC1493BridgeMIB

RFC1573SNMPMIBII

RFC1643EthernetMIB

RFC1657BGP-4MIB

RFC1724RIPv2MIB

RFC1757RemoteNetworkMonitoringMIB

RFC1850OSPFv2MIB

RFC2011SNMPv2MIBforIP

RFC2012SNMPv2MIBforTCP

RFC2013SNMPv2MIBforUDP

RFC2021RMONv2MIB

RFC2096IPForwardingTableMIB

RFC2233InterfacesMIB

RFC2273SNMP-NOTIFICATION-MIB

RFC2452IPV6-TCP-MIB

RFC2454IPV6-UDP-MIB

RFC2465IPv6MIB

RFC2466ICMPv6MIB

RFC2571SNMPFrameworkMIB

RFC2572SNMP-MPDMIB

RFC2573SNMP-TargetMIB

RFC2613SMONMIB

RFC2618RADIUSClientMIB

RFC2620RADIUSAccountingMIB

RFC2665Ethernet-Like-MIB

RFC2674802.1pandIEEE802.1QBridgeMIB

RFC2737EntityMIB(Version2)

RFC2787VRRPMIB

RFC2819RMONMIB

RFC2863TheInterfacesGroupMIB

RFC2925PingMIB

RFC2932IP(MulticastRoutingMIB)

RFC2933IGMPMIB

RFC3273HC-RMONMIB

RFC3414SNMP-Userbased-SMMIB

RFC3415SNMP-Viewbased-ACMMIB

RFC3418MIBforSNMPv3

RFC3621PowerEthernetMIB

RFC3813MPLSLSRMIB

RFC3814MPLSFTNMIB

RFC3815MPLSLDPMIB

RFC3826AESforSNMP’sUSMMIB

RFC4133EntityMIB(Version3)

LLDP-EXT-DOT1-MIB

LLDP-EXT-DOT3-MIB

LLDP-MIB

MPLS RFC2205ResourceReSerVationProtocol(RSVP)-Version1FunctionalSpecification

RFC2209ResourceReSerVationProtocol(RSVP)

RFC2702RequirementsforTrafficEngineeringOverMPLS

RFC2858MultiprotocolExtensionsforBGP-4

RFC3031MultiprotocolLabelSwitchingArchitecture

RFC3032MPLSLabelStackEncoding

RFC3036LDPSpecification

RFC3107CarryingLabelInformationinBGP-4

RFC3209RSVP-TE:ExtensionstoRSVPforLSPTunnels

RFC3479FaultTolerancefortheLabelDistributionProtocol(LDP)

RFC3487GracefulRestartMechanismforLDP

RFC4090FastRerouteExtensionstoRSVP-TEforLSPTunnels

RFC4364BGP/MPLSIPVirtualPrivateNetworks(VPNs)

RFC4379DetectingMulti-ProtocolLabelSwitched(MPLS)DataPlaneFailures

RFC4447PseudowireSetupandMaintenanceUsingLDP

RFC4448EncapsulationMethodsforTransportofEthernetoverMPLSNetworks

RFC4664FrameworkforLayer2VirtualPrivateNetworks

RFC4665ServiceRequirementsforLayer2ProviderProvisionedVirtualPrivateNetworks

RFC4761VirtualPrivateLANService(VPLS)UsingBGPforAuto-DiscoveryandSignaling

RFC4762VirtualPrivateLANService(VPLS)UsingLabelDistributionProtocol(LDP)Signaling

24

Data sheet | HP 12500 Switch Series

Standards and Protocols

(appliestoallproductsinseries)

Network management IEEE802.1ABLinkLayerDiscoveryProtocol(LLDP)

IEEE802.1D(STP)

RFC1155StructureofManagementInformation

RFC1157SNMPv1

RFC1215SNMPGenerictraps

RFC1757RMON4groups:Stats,History,AlarmsandEvents

RFC1905SNMPv2ProtocolOperations

RFC2211Controlled-LoadNetwork

RFC2272SNMPv3ManagementProtocolRFC2273SNMPv3Applications

RFC2274USMforSNMPv3

RFC2571SNMPManagementFrameworksRFC2572SNMPv3MessageProcessing

RFC2573SNMPv3Applications

RFC2576CoexistencebetweenSNMPversions

RFC2578SMIv2

RFC2819FourgroupsofRMON:1(statistics),2(history),3(alarm)and9(events)

RFC3164BSDsyslogProtocol

RFC3415SNMPv3View-basedAccessControlModelVACM)

ANSI/TIA-1057LLDPMediaEndpointDiscovery(LLDP-MED)

SNMPv1/v2c/v3

OSPF RFC1245OSPFprotocolanalysis

RFC1246ExperiencewithOSPF

RFC1587OSPFNSSA

RFC1765OSPFDatabaseOverflow

RFC1850OSPFv2ManagementInformationBase(MIB),traps

RFC2328OSPFv2

RFC2370OSPFOpaqueLSAOption

RFC3101OSPFNSSA

RFC3623GracefulOSPFRestart

QoS/CoS IEEE802.1P(CoS)

RFC2212GuaranteedQualityofService

RFC2474DSFieldintheIPv4andIPv6Headers

RFC2475DiffServArchitecture

RFC2597DiffServAssuredForwarding(AF)

RFC2598DiffServExpeditedForwarding(EF)

RFC2697ASingleRateThreeColorMarker

RFC2698ATwoRateThreeColorMarkerBi-directionalRateShaping

Security IEEE802.1AEMACSecurityStandard(MACSec)

IEEE802.1XPortBasedNetworkAccessControl

RFC1321TheMD5Message-DigestAlgorithmRFC2082RIP-2MD5Authentication

RFC2104Keyed-HashingforMessageAuthentication

RFC2716PPPEAPTLSAuthenticationProtocol

RFC2865RADIUSAuthentication

RFC2866RADIUSAccounting

RFC2867RADIUSAccountingModificationsforTunnelProtocolSupport

RFC2868RADIUSAttributesforTunnelProtocolSupport

RFC2869RADIUSExtensions

RFC3567IntermediateSystem(IS)toISCryptographicAuthentication

AccessControlLists(ACLs)

GuestVLANfor802.1x

MACAuthentication

SSHv2SecureShell

WebAuthentication

IKEv1 RFC2865—RemoteAuthenticationDialInUserService(RADIUS)

25

Data sheet | HP 12500 Switch Series

HP 12500 Switch Series accessories

Modules NEWHPFlexFabric12500EMainProcessingUnit(JG802A)

HP12500TypeAMainProcessingUnitwithComwarev7OperatingSystem(JG497A)

HP12500MainProcessingUnit(JC072B)

NEWHPFlexFabric125004-port100GbECFPFDModule(JG786A)

NEWHPFlexFabric125004-port100GbECFPFGModule(JG788A)

NEWHPFlexFabric1250016-port40GbEQSFP+FDModule(JG790A)

NEWHPFlexFabric1250048-port1/10GbESFP+FDModule(JG796A)

NEWHPFlexFabric1250040-port1/10GbESFP+FDModule(JG792A)

NEWHPFlexFabric1250040-port1/10GbESFP+FGModule(JG794A)

HP1250016-port10GbESFP+LEBModule(JC782A)

HP1250016-port10GbESFP+LECModule(JC783A)

HP1250032-port10GbESFP+REBModule(JC064B)

HP1250032-port10GbESFP+RECModule(JC476B)

HP125008-port10GbESFP+LEBModule(JC780A)

HP125008-port10GbESFP+LECModule(JC781A)

HP125008-port10GbESFP+LEFModule(JC659A)

HP125008-port10GbEXFPLEBModule(JC073B)

HP125008-port10GbEXFPLECModule(JC068B)

HP1250048-portGig-TLEBModule(JC074B)

HP1250048-portGig-TLECModule(JC065B)

HP1250048-portGbESFPLEBModule(JC075B)

HP1250048-portGbESFPLECModule(JC069B)

HP1250048-portGbESFPLEFModule(JC660A)

HP12500PowerMonitorModule(JC502A)

26

Data sheet | HP 12500 Switch Series

Transceivers HPX120100M/1GSFPLCLXTransceiver(JF832A)

HPX114100MSFPLCFXTransceiver(JF833A)

HPX1251GSFPLCLH401310nmTransceiver(JD061A)

HPX1201GSFPLCLH401550nmTransceiver(JD062A)

HPX1251GSFPLCLH70Transceiver(JD063B)

HPX1201GSFPRJ45TTransceiver(JD089B)

HPX1201GSFPLCBX10-UTransceiver(JD098B)

HPX1201GSFPLCBX10-DTransceiver(JD099B)

HPX1201GSFPLCLH100Transceiver(JD103A)

HPX1701GSFPLCLH701550Transceiver(JD109A)

HPX1701GSFPLCLH701570Transceiver(JD110A)

HPX1701GSFPLCLH701590Transceiver(JD111A)

HPX1701GSFPLCLH701610Transceiver(JD112A)

HPX1701GSFPLCLH701470Transceiver(JD113A)

HPX1701GSFPLCLH701490Transceiver(JD114A)

HPX1701GSFPLCLH701510Transceiver(JD115A)

HPX1701GSFPLCLH701530Transceiver(JD116A)

HPX1201GSFPLCSXTransceiver(JD118B)

HPX1201GSFPLCLXTransceiver(JD119B)

HPX13010GXFPLCZRTransceiver(JD107A)

HPX13010GXFPLCLRTransceiver(JD108B)

HPX13010GXFPLCSRTransceiver(JD117B)

HPX13510GXFPLCERTransceiver(JD121A)

HPX18010GXFPLCLH80km1538.98nmDWDMTransceiver(JG226A)

HPX18010GXFPLCLH80km1539.77nmDWDMTransceiver(JG227A)

HPX18010GXFPLCLH80km1540.56nmDWDMTransceiver(JG228A)

HPX18010GXFPLCLH80km1542.14nmDWDMTransceiver(JG229A)

HPX18010GXFPLCLH80km1542.94nmDWDMTransceiver(JG230A)

HPX18010GXFPLCLH80km1558.98nmDWDMTransceiver(JG231A)

HPX18010GXFPLCLH80km1559.79nmDWDMTransceiver(JG232A)

HPX18010GXFPLCLH80km1560.61nmDWDMTransceiver(JG233A)

HPX13010GSFP+LCSRTransceiver(JD092B)

HPX13010GSFP+LCLRMTransceiver(JD093B)

HPX13010GSFP+LCLRTransceiver(JD094B)

HPX13010GSFP+LCER40kmTransceiver(JG234A)

HPX24010GSFP+toSFP+3mDirectAttachCopperCable(JD097C)

HPX24010GSFP+toSFP+5mDirectAttachCopperCable(JG081C)

HPX24010GSFP+SFP+7mDirectAttachCopperCable(JC784C)

HPX14040GQSFP+MPOSR4Transceiver(JG325B)

HPX14040GQSFP+MPOMM850nmCSR4300mTransceiver(JG709A)

HPX14040GQSFP+LCLR4SM10km1310nmTransceiver(JG661A)

NEWHPX150100GCFPLCLR410kmSMTransceiver(JG829A)

HPX13010GSFP+LCLH80kmTransceiver(JG915A)

Cables HPPremierFlexLC/LCMulti-modeOM42fiber1mCable(QK732A)

HPPremierFlexLC/LCMulti-modeOM42fiber2mCable(QK733A)

HPPremierFlexLC/LCMulti-modeOM42fiber5mCable(QK734A)

HPPremierFlexLC/LCMulti-modeOM42fiber15mCable(QK735A)

HPPremierFlexLC/LCMulti-modeOM42fiber30mCable(QK736A)

HPPremierFlexLC/LCMulti-modeOM42fiber50mCable(QK737A)

Mounting Kit HPX421ChassisUniversal4-postRackMountingKit(JC665A)

Appliance HP1250020GbpsVPNFirewallModule(JG371A)

HP 12500 Switch Series accessories (continued)

27

Data sheet | HP 12500 Switch Series

Memory NEWHPFlexFabric4GBCompactFlashCard(JG806A)

NEWHPFlexFabric4GBDDR3SDRAM(JG807A)

HPX6001GCompactFlashCard(JC684A)

HP2GBRegisteredDDR2SDRAMMemory(JC609A)

HPX6101GBDDR2SDRAMMemory(JC071A)

HP 12504 AC Switch Chassis (JC654A) HP1250xG2FabricModule(JC658A)

HP12500ACPowerEntryModule(JF426A)

HP125002000WACPowerSupply(JF429A)

HP12504FanAssembly(JC664A)

HP 12504 DC Switch Chassis (JC655A) HP1250xG2FabricModule(JC658A)

HPX21010-meterJGConnectortoBare6AWG37800Watt72VDCPowerCable(JG280A)

HP125001800WDCPowerSupply(JC651A)

HP12504FanAssembly(JC664A)

HP 12508 AC Switch Chassis (JF431C) HP12508FabricModule(JC067B)

HP1250xG2FabricModule(JC658A)

HP12508TopandBottomCableGuidesforACPoweredSwitch(JC785A)

HP12500SideCableManagementGuide(JC084A)

HP125002000WACPowerSupply(JF429A)

HP12500ACPowerEntryModule(JF426A)HP12508FanAssembly(JC081A)

HP12508OptionalAirFilter(JC082A)

HP 12508 DC Switch Chassis (JC652A) HP12508FabricModule(JC067B)

HP1250xG2FabricModule(JC658A)

HP12508TopandBottomCableGuidesforDCPoweredSwitch(JC787A)

HP12500SideCableManagementGuide(JC084A)

HPX21010-meterJGConnectortoBare6AWG37800Watt72VDCPowerCable(JG280A)

HP125001800WDCPowerSupply(JC651A)

HP12508FanAssembly(JC081A)

HP12508OptionalAirFilter(JC082A)

HP 12518 AC Switch Chassis (JF430C) HP12518G2FabricModule(JC657A)

HP12518FabricModule(JC066A)

HP12518TopandBottomCableGuidesforACPoweredSwitch(JC786A)

HP12500SideCableManagementGuide(JC084A)

HP125002000WACPowerSupply(JF429A)

HP12500ACPowerEntryModule(JF426A)

HP12518FanAssembly(JC080A)

HP12518OptionalAirFilter(JC083A)

HP 12518 DC Switch Chassis (JC653A) HP12518G2FabricModule(JC657A)

HP12518FabricModule(JC066A)

HP12518TopandBottomCableGuidesforDCPoweredSwitch(JC788A)

HP12500SideCableManagementGuide(JC084A)

HPX21010-meterJGConnectortoBare6AWG37800Watt72VDCPowerCable(JG280A)

HP125001800WDCPowerSupply(JC651A)

HP12518FanAssembly(JC080A)

HP12518OptionalAirFilter(JC083A)

HP FlexFabric 12508E AC Switch Chassis (JG782A)

NEWHPFlexFabric12508EFabricModule(JG798A)

NEWHPFlexFabric12508EOptionalExtendedCableGuideforACPoweredSwitch(JG830A)

NEWHPFlexFabric12508EOptionalExtendedCableGuideforDCPoweredSwitch(JG832A)

HP125002000WACPowerSupply(JF429A)

NEWHPFlexFabric12500ESparePowerMonitorModule(JG804A)

NEWHPFlexFabric12500EFanTrayAssembly(JG805A)

NEWHPFlexFabric12508EOptionalAirFilter(JG808A)

HP 12500 Switch Series accessories (continued)

RatethisdocumentSharewithcolleagues

Sign up for updates hp.com/go/getupdated

©Copyright2010-2014Hewlett-PackardDevelopmentCompany,L.P.Theinformationcontainedhereinissubjecttochangewithoutnotice.TheonlywarrantiesforHPproductsandservicesaresetforthintheexpresswarrantystatementsaccompanyingsuchproductsandservices.Nothinghereinshouldbeconstruedasconstitutinganadditionalwarranty.HPshallnotbeliablefortechnicaloreditorialerrorsoromissionscontainedherein.

MicrosoftisaregisteredtrademarkoftheMicrosoftgroupofcompanies.

4AA3-0666ENW,August2014,Rev.13

Datasheet|HP12500SwitchSeries

ProductswithinthisserieshaveachievedsufficientscoresineachoftheratedcriteriatoachievetheMiercomCertifiedGreendistinctionAward.SeetheSpecificationssectionofthisseriesformoreinformation.

HP FlexFabric 12508E DC Switch Chassis (JG783A)

NEWHPFlexFabric12508EFabricModule(JG798A)

HP12508TopandBottomCableGuidesforDCPoweredSwitch(JC787A)

HP12500SideCableManagementGuide(JC084A)

HPX21010-meterJGConnectortoBare6AWG37800Watt72VDCPowerCable(JG280A)

NEWHPFlexFabric12508EOptionalExtendedCableGuideforDCPoweredSwitch(JG832A)

HP125001800WDCPowerSupply(JC651A)

NEWHPFlexFabric12500ESparePowerMonitorModule(JG804A)

NEWHPFlexFabric12500EFanTrayAssembly(JG805A)

NEWHPFlexFabric12508EOptionalAirFilter(JG808A)

HP FlexFabric 12518E AC Switch Chassis (JG784A)

NEWHPFlexFabric12518EFabricModule(JG800A)

HP12518TopandBottomCableGuidesforACPoweredSwitch(JC786A)

HP12500SideCableManagementGuide(JC084A)

NEWHPFlexFabric12518EOptionalExtendedCableGuideforACPoweredSwitch(JG831A)

HP125002000WACPowerSupply(JF429A)

HP12500ACPowerEntryModule(JF426A)

NEWHPFlexFabric12500ESparePowerMonitorModule(JG804A)

NEWHPFlexFabric12500EFanTrayAssembly(JG805A)

NEWHPFlexFabric12518EOptionalAirFilter(JG809A)

HP FlexFabric 12518E DC Switch Chassis (JG785A)

NEWHPFlexFabric12518EFabricModule(JG800A)

HP12518TopandBottomCableGuidesforDCPoweredSwitch(JC788A)

HP12500SideCableManagementGuide(JC084A)

HPX21010-meterJGConnectortoBare6AWG37800Watt72VDCPowerCable(JG280A)

NEWHPFlexFabric12518EOptionalExtendedCableGuideforDCPoweredSwitch(JG833A)

HP125001800WDCPowerSupply(JC651A)

NEWHPFlexFabric12500ESparePowerMonitorModule(JG804A)

NEWHPFlexFabric12500EFanTrayAssembly(JG805A)

NEWHPFlexFabric12518EOptionalAirFilter(JG809A)