HT-ST 1200 and HT-SSQ 1200 Split Furnaces for Testing Machines
1
-
High Temperature Laboratory Furnaces
HT-ST 1200 Split TubeHT-SSQ 1200 Split Square
Furnaces for Testing Machines
MICROTEST
MICROTEST
MICROTEST, S.A.
Instruments and Equipments for Materials Testing
(+34) 91 796 33 32 www.microtest-sa.com
7/29/2019 HT ST 1200 and HT SSQ 1200 High Temperature Split Furnaces for Testing Machines MICROTEST ENGLISH
http://slidepdf.com/reader/full/ht-st-1200-and-ht-ssq-1200-high-temperature-split-furnaces-for-testing-machines 2/6
HT-ST 1200 and HT-SSQ 1200 Split Furnaces for Testing Machines
2
HT-ST 1200
MICROTEST Split Tube Furnaces for Testing Machines: 1200°C
DESCRIPTION
The standard application for high temperature tests includes a 3-zone resistancewire wound furnace. The cylindrical split construction allows an easy and quickloading of the prepared sample train. The temperature ranges from ambient (25°C) to1200°C with a state-of-the-art digital programmable temperature Eurotherm 2704controller.
Typical applications are: high temperature tensile tests, creep tests, stress rupturetests, LCF or fracture mechanics.
Typical samples are metal alloys with different geometries: threaded or shoulder endround or flat specimens.
Stainless furnace cover and asbestos-free insulation material (bio-soluble fibre).
Typical Heating element in Kanthal – A1 (*).
Max. Temperature: 1000°C -1100ºC on the sample.
Typical Operating Voltage: 230 V AC single phase 50 Hz (other voltages underrequest).
Every zone in the oven has its own heater that can be controlled through a type K
(altern. R, J or S) thermocouple and a sample thermocouple type K or S (total of 3thermocouples on the specimen) in a dual loop process (typically cascade control) withstandard color coded connectors and cables. This configuration leads to a high
temperature homogeneity on the sample and stability (less than ±1°C both cases)and a precise temperature long term control, without overshooting. The uniformtemperature zone (±1ºC) is at the middle of the furnace and at least 100-150mm.
Another set of three thermocouples is used to protect the furnace from accidentaloverheating (limiting over temperature control). The system includes additionalindividual controllers for these limiters, with a first limit to set the power down to zerofor the corresponding zone and a second one to stop the whole system for security.
The 2704 Eurotherm controller Integrates a sophisticated PID Control-Algorithmfor a precise Temperature along specimen and to prevent temperature overshooting.Each zone is individually adjustable for power to attain temperature uniformity on the
specimen length. Temperature control setting can be from 25°C to 1200°C.Thermocouple break protection is available. Cold junction compensation - Automatic(internal) and 45 and 50°C (external user selectable).
For each zone, the power is driven by Eurotherm Thyristors. The control unit system
includes fuse holders and fuses and furnace over temperature shutdown relay andcontactors.
The controller can operate in a stand-alone mode, including digital display of set andprocess temperature values or be operated by PC. The MICROTEST SCM3000software allows this operation including displaying and recording of temperatures astest data.
The furnace is a split design type, with adapter to machine pull rods, concentricallyplaced along the test axis. Top and bottom finish insulation is in low thermalconducting (low 'K' factor) vacuum cast ceramic fibre insulation to provide minimumheat loss, high temperature capability and for rigid structure.
(*)Kanthal A-1 is a ferritic iron-chromium-aluminium alloy (FeCrAl alloy) with high resistivity and very good oxidation
resistance. It is suitable for use at temperatures up to 1400°C (2550°F). Typical applications for Kanthal A-1 are
electrical heating elements in high-temperature furnaces for heat treatment, ceramics, glass, steel, and electronics
industries.
7/29/2019 HT ST 1200 and HT SSQ 1200 High Temperature Split Furnaces for Testing Machines MICROTEST ENGLISH
http://slidepdf.com/reader/full/ht-st-1200-and-ht-ssq-1200-high-temperature-split-furnaces-for-testing-machines 3/6
HT-ST 1200 and HT-SSQ 1200 Split Furnaces for Testing Machines
3
Ceramic end caps at the top fit snugly around pull rod and the bottom end cap havecut out for extensometer arms and pull rod and reduce the heat loss at this points.Bottom side end cap are secured with quick retainer clamps to keep the tight fitting of the above thermal insulation boards to seal the leakages.
The machine frame is usually adapted to accommodate the furnace. It uses an extra-large testing area and the vertical clearance allows an easy management of the
furnace. The furnace is mounted on the machine frame such that the position of thefurnace is normally adjustable vertically.
Operating Voltage: 230 V AC single phase 50 Hz or 400Vac AC 3 phases (underdemand). Furnace power cables of suitable length.
The furnace dimensions are usually adapted to the end user application. To achieve a suitable low external surface temperature, an extra cover in stainless
steel acts as thermal shield for operator protection: extermal temperature <50°C.
SpecificationsTypical
Values MOUNTING
BRACKETS
Depending on the
application and type
of machine, the
furnace is supplied with the mounting
brackets to support
the furnace during
the tests and allowing
it to be retired out of
the testing area when
not in use.
Max. temperature: 1250°C
Min. temperature: 50 °C
Max. temperature on the sample 1000-1200°C
Heating rate: 10-20 °C/minOuter diameter (*): >295 mm
Outer height (*): 380-420 mm
Nominal voltage: 3 x 240 V
Heating zones 3
Nominal power 2.5 to 3.6 kW
Temp. Homogeneity on sample≤±1°C (steady
state)
Temp Stability : ≤±1°C
Constancy zone )*) : 100-200 mm
Inner diameter (*): 80-120 mm
Heated length/zone (*): 150-300 mm
(*) Typical values. Final dimensions depends on the application
7/29/2019 HT ST 1200 and HT SSQ 1200 High Temperature Split Furnaces for Testing Machines MICROTEST ENGLISH
http://slidepdf.com/reader/full/ht-st-1200-and-ht-ssq-1200-high-temperature-split-furnaces-for-testing-machines 4/6
HT-ST 1200 and HT-SSQ 1200 Split Furnaces for Testing Machines
4
HT-SSQ 1200
MICROTEST Split Square Furnaces for Testing Machines: 1200°C
The HT-SSQ 1200 furnace is another version for
MICROTEST 1200°C furnaces where the inner shape of the working space is square or rectangular.
The arrangement of the working space is adapted to
the customer’ s needs.
This construction allows the use of fixtures and grips
that are difficult to apply in round shaped furnaces.
There is a wide possibility of selection of widths,
lengths and heights for the working area.
These furnaces have also upper and lower load train
ports (holes) with adapters to machine pull rods,
concentrically placed along the test axis.
The HT-SSQ 1200 furnaces can dispose of one or three heating zones, depending onthe application and the available space.
The furnace is available with additional heavy duty brackets or mountings, which
attach to a wide range of testing systems.
The furnace can be placed within the loading space in a testing machine and the
mounting elements allows the furnace to retired from the machine when not in use.
In the case of three zone furnaces, the specifications are similar to those described for
model HT-ST 1200 furnaces.
Main Features are:
Stainless Steel Shell
Ceramic shell heater with Kanthal A1
(2200°F/1200°C), or Kanthal APM Winding(1250°C)
Low K-factor vacuum cast ceramic fiberinsulation
Build-to-Order
SpecificationsTypical
Values MOUNTING
BRACKETS
Depending on the
application and type
of machine, the
furnace is supplied
with the mountingbrackets to support
the furnace during
the tests and allowing
it to be retired out of
the testing area when
not in use.
Max. temperature: 1250°C
Min. temperature (from ambient to): 50 °C
Max. temperature on the sample 1000-1100-1200°C
Heating rate: 8-20 °C/min
Outer/Inner width (*): 255/155 mm-500/400mm
Outer/Inner height (*):350/250mm-
600/500mm
Nominal voltage: 3 x 240 V
Heating zones 1 to 3
Nominal power 2.5 to 4 kW
Temp. Homogeneity on sample (*)≤±2°C (steady
state)
Temp Stability (*) ≤±2°C
Constancy zone (*) : 100-200 mm
Load train ports 2 ports
Heated length/zone (*): 150-300 mm(*) Typical values. Final dimensions depends on the application and the desired working space
7/29/2019 HT ST 1200 and HT SSQ 1200 High Temperature Split Furnaces for Testing Machines MICROTEST ENGLISH
http://slidepdf.com/reader/full/ht-st-1200-and-ht-ssq-1200-high-temperature-split-furnaces-for-testing-machines 5/6
HT-ST 1200 and HT-SSQ 1200 Split Furnaces for Testing Machines
5
Extensometer ports
Depending on the high temperature extensometer to be used, the furnace has an optional
cut-out to allow the use of side or bottom entry high temperature extensometry.
Temperature controller unit
The temperature controller unit includes a 2704 Eurotherm controller, the power unit andcommunication to the machine control unit by USB port.
The 2704 Eurotherm controller Integrates a sophisticated PID Control-Algorithm for aprecise Temperature along specimen and to prevent temperature overshooting. Each zone isindividually adjustable for power to attain temperature uniformity on the specimen length.Temperature control setting can be from 25°C to 1200°C. Thermocouple break protection is
available. Cold junction compensation Automatic (internal) and 45 and 50°C (external userselectable).
For each zone, the power is driven by Eurotherm Thyristors. The control unit system includesfuse holders and fuses and furnace over temperature shutdown relay and contactors.The controller can operate in a stand-alone mode, including digital display of set and processtemperature values or be operated by PC. The MICROTEST SCM3000 software allows thisoperation including displaying and recording of temperatures as test data.
7/29/2019 HT ST 1200 and HT SSQ 1200 High Temperature Split Furnaces for Testing Machines MICROTEST ENGLISH
http://slidepdf.com/reader/full/ht-st-1200-and-ht-ssq-1200-high-temperature-split-furnaces-for-testing-machines 6/6
HT-ST 1200 and HT-SSQ 1200 Split Furnaces for Testing Machines
6
Pull rods and adapters
A variety of pull rods and specimen adapters are available to
accommodate various specimen geometries. They are made of special
high-temperature materials for durability and ease of use. High
Temperature Pull Rods and adapter are in Inconel 718 or 713C
or other Ni based high temperature alloys.
Specimen Holders are easily removed from the pull rods to allow rapid
interchange of flat, threaded, or button head specimen shapes.
One of the standard configuration is applied for threaded samples
(M6, M8, M10,…).
This configuration makes use of interchangeable threaded couplings
made in high temperature resistant NI-base alloy or super-alloy and
defined for every type of threaded sample.
Other types of grips are made of Inconel-713C or 718 to fix into pull rods for high
temperature tensile tests of samples. For button head specimens, collars to hold the
specimens can also be supplied.Other adapters: pin and clevis specimen holders for mounting of flat specimens with a
mounting hole diameter, threaded-end specimen holders, special wedge grips, etc. in high
temperature alloys.
Other MICROTEST Furnaces for Testing
A complete line of different laboratory furnaces can be manufactured and supplied byMICROTEST.
From medium temperatures ovens (150-250°C) to high temperature furnaces (1800°C,
with heaters in MoSi2), MICROTEST furnaces and ovens are constructed using all stainlesssteel exteriors and high quality ceramic thermal isolation. They are designed to work withmaterial testing systems of all types, such as Tensile Testing, Fatigue Testing,Compression Testing, Creep Testing or Tribological Testing, and can bemanufactured for new OEM systems or for retrofitting to an existing system.
MICROTEST Laboratory furnaces and ovens can be designed for horizontal or verticaloperation and optionally supplied with various types of mounting brackets or stands aswell as ports for atmosphere introduction.
MICROTEST Furnaces can be customized to the end user specifications.