iguana circo freestanding - jaga · iguana circo wall mounted model 4. iguana circo corner 5....
Post on 20-Aug-2020
7 Views
Preview:
TRANSCRIPT
1
32
4
75 6
1. Iguana Circo Freestanding 2. Iguana Circo Pillar cover 3. Iguana Circo Wall mounted model 4. Iguana Circo Corner 5. Iguana Aplano
12 6. Iguana Arco 7. Iguana Visio
14
1
2
1. Iguana Circo Freestanding Top view 2. Iguana Circo Freestanding
Iguana Circo Freestanding
15
5.0
Ø
G1/2" 8
8
Iguana Circo Freestanding Dimensions CIRF_Circo Freestanding
2.5
4.5 ø
16 E
air vent G 1/8” 5.0
0.25 G1/2"
9.5
H
7.0
ø3.523.0
13
0.8
5.0
L-9.0 Ø
Metal suspension column included
Position flow and return pipe
Connections Two pipe Standard connection
Code MM
Please note: With the guard the standard flow is on the left. If a right hand flow is required please amend the code suffix using MM/CR
M M
Notice To guarantee the output of the Iguana models and to limit the pressure drop, Jaga recommends the use of tube diameter 16/2, 18/1 or 18/2.
Dimensions options Table
Ø 27.8 31.3 34.8
L 66.0 73.0 80.0D
D 50.0 55.0 60.0
L Example with 2 tables
Large shelf 17
Ø 27.8 31.3 34.8
L 63.7 67.2 70.7 D
D 31.2 32.9 34.7L
Small shelf
Ø 27.8 31.3 34.8 10
E
L 49.7 53.2 56.7 D
D 24.2 25.9 27.7L
Towel rail
Ø 27.8 31.3 34.8
Standard delivery: L 42.7 42.7 49.3D
guard and connection set with thermostatic valve and lockshield included. D 22.1 22.1 25.3 L
Sleeve couplings for Connection sets with guard see page 209.
Hat rack Dimensions in cm
Ø 27.8 31.3 34.8 Ø 27.8 31.3 34.8
L 42.7 42.7 49.3 D E 7.5 9.4 11.3
D 22.1 22.1 25.3 L
L
17
Outputs
Standard delivery : - Iguana Circo in 2 parts, to be
mounted around the suspension column, incl. all pieces for hydraulic connection
- support with suspension column and guards with opening for the
H
23
valve head - thermostatic valve 5094.430 - lockshield 5094.431 - 4 chrome-plated air vents G 1/8” - sleeve couplings: see Connection
sets & Valves
Standard colours: - sandblast grey metallic 001 - white 301(RAL 9010 satin) - white 333(RAL 9016 satin)
code height length colour conn.
ORDERING CODE: CIRF. 180 027. XXX /MM /CL
Iguana CIRF
H L 027 031 034
180 75/65/20 1602 1893 2184 90/70/20 2081 2460 2838 s o
192 75/65/20 1707 2018 2328 90/70/20 2211 2613 3015 s ot
200 75/65/20 1773 2096 2418 90/70/20 2291 2708 3125 s o
220 75/65/20 90/70/20 s o
1923 2272 2622 2471 2919 3369
240 75/65/20 2048 2421 2793 90/70/20 2617 3094 3569 st ot
Options Table in beech veneer
CODE Type
9087.012660 Circo ø 27 9087.012730 Circo ø 31 9087.012800 Circo ø 34
Large shelf in beech veneer
CODE Type
9087.010637 Circo ø 27 9087.010672 Circo ø 31 9087.010707 Circo ø 34
Small shelf in beech veneer
CODE Type
9087.011497 Circo ø 27 9087.011532 Circo ø 31 9087.011567 Circo ø 34
Towel rail chrome-plated aluminium
Igua
na C
irco
Fre
esta
ndin
g
CODE Type
9087.013427 Circo ø 27 9087.013427 Circo ø 31 9087.013493 Circo ø 34
Hat rack chrome-plated aluminium
CODE Type
9087.014427 Circo ø 27 9087.014427 Circo ø 31 9087.014493 Circo ø 34
Deco thermostatic head
chrome / white
CODE Colour
5090.1111 chrome 5090.1110 chrome / white
chrome
Foot for concrete floor
CODE Type
9086.000278 Circo ø 27 9086.000313 Circo ø 31 9086.000348 Circo ø 34
Finished floor level
Page Rod (thread M16 ) not
Output measured in accordance C3 delivered as standard.
with EN442, at a water tempera- T9ture of 75/65 and a room tempe- C3rature of 20°C (ΔT=50). P2
18
Iguana Circo Pillar cover
5.0
G1/2"
Ø
8
8
Iguana Circo Pillar cover Dimensions Connections CIRP_Circo Pilar Two pipe Standard connection
Code MM 2.5
Please note: 4.5 With the guard the standard flow
ø E is on the left. If a right hand flow
20 is required please amend the Architectural or concrete pilar 5.0 code suffix using MM/CR
0.25 G1/2" air vent G 1/8” øz
9.5
M M
H Notice To guarantee the output of the Iguana models and to limit the pressure drop, Jaga recommends the use of tube diameter 16/2, 18/1 or 18/2.
Dimensions options Table
Ø 27.8 31.3 34.8
L 66.0 73.0 80.0 D ø3.5 D 50.0 55.0 60.0
23.0 13.0 Example with 2
0.8 L tables 5.0 Large shelf
17L-9.0 Ø 27.8 31.3 34.8
Ø
Position flow and return pipe L 63.7 67.2 70.7 D
D 31.2 32.9 34.7L
Small shelf
Ø 27.8 31.3 34.8 10E
L 49.7 53.2 56.7 D
D 24.2 25.9 27.7L
Towel rail
Ø 27.8 31.3 34.8 Standard delivery: guard and connection set with thermostatic valve and lockshield included. L 42.7 42.7 49.3 D
Sleeve couplings for connection sets with guard see page 209. D 22.1 22.1 25.3 L
Dimensions in cm Hat rack
Ø 27.8 31.3 34.8 Ø 27.8 31.3 34.8
E 7.5 9.4 11.3 L 42.7 42.7 49.3 D
ØZ 11.0 12.5 16.0 D 22.1 22.1 25.3 L
21
Outputs
H
23
Standard delivery : - Iguana circo in 2 parts, including all
pieces for hydraulic connection L - suspension brackets for mounting
around construction column - guards with opening for valve head - thermostatic valve 5094.430 - lockshield 5094.431 - 4 chrome-plated air vents G 1/8” - sleeve couplings: see Connection
sets & Valves
Standard colours: - sandblast grey metallic 001 - white 301(RAL 9010 satin) - white 333(RAL 9016 satin)
Iguana CIRP code height length colour conn.
ORDERING CODE: CIRF. 180 027. XXX /MM /CL
H L 027 031 034
180 75/65/20 1602 1893 2184 90/70/20 2081 2460 2838 s o
192 75/65/20 1707 2018 2328 90/70/20 2211 2613 3015 s o
200 75/65/20 1773 2096 2418 90/70/20 2291 2708 3125 s o
220 75/65/20 1923 2272 2622 90/70/20 2471 2919 3369 s o
240 75/65/20 2048 2421 2793 90/70/20 2617 3094 3569 s o
Options Table in beech veneer
CODE Type
9087.012660 Circo ø 27 9087.012730 Circo ø 31 9087.012800 Circo ø 34
Large shelf in beech veneer
CODE Type
9087.010637 Circo ø 27 9087.010672 Circo ø 31 9087.010707 Circo ø 34
Small shelf in beech veneer Igua
na C
irco
Pill
ar c
over
CODE Type
9087.011497 Circo ø 27 9087.011532 Circo ø 31 9087.011567 Circo ø 34
Towel rail chrome-plated aluminium
CODE Type
9087.013427 Circo ø 27 9087.013427 Circo ø 31 9087.013493 Circo ø 34
Hat rack chrome-plated aluminium
CODE Type
9087.014427 Circo ø 27 9087.014427 Circo ø 31 9087.014493 Circo ø 34
Deco thermostatic head
CODE Colour
5090.1111 chrome 5090.1110 chrome / white chrome / white
chrome
Output measured in accordance with EN442, at a water tempera- ture of 75/65 and a room tempe-rature of 20°C (ΔT=50).
1
2
1. Iguana Circo Wall Model (at the top) 2. Iguana Circo Wall Model (below)
22
23
Iguana Circo Wall Model
24
Iguana Circo Wall mounted model Dimensions CIRW_Circo Wall
D 4.5
0.25 5.0
E
C
ø
G1/2" air vent G 1/8”
Option: guard
13.0ø3.5
9.5
H
7.6
Connections Two pipe Standard connection
4 5 Code MM
Top end connection Code 45 or 54 (1° number > flow) When ordering a top end con-nection, no insert pipe should be ordered. Air vents should be positioned on the central heating pipes. Ordering code: specify code 45 or 54 instead if MM, no sur-charge.
One pipe connection M M The standard radiator can be
connected to a one pipe system with connection sets 41 or 42. With a maximum of 2 radiators per heating ring.
Notice To guarantee the output of the Iguana models and to limit the pressure drop, Jaga recommends the use of tube diameter 16/2, 18/1 or 18/2.
Dimensions options Table
Ø 27.8 31.3 34.8
L 66.0 73.0 80.0 D 50.0 55.0 60.0
L
D
Large shelf
Ø 27.8 31.3 34.8
L 63.7 67.2 70.7 D 31.2 32.9 34.7
L 17
D
Small shelf
Ø 27.8 31.3 34.8
L 49.7 53.2 56.7 D 24.2 25.9 27.7
L 10
D
Towel rail
Ø 27.8 31.3 34.8
L 42.7 42.7 49.3 D 22.1 22.1 25.3
D
L
8
Hat rack
Ø 27.8 31.3 34.8
L 42.7 42.7 49.3 D 22.1 22.1 25.3
D
L
8
min. 10 cmWith guard 23 cm
ø
Position flow and return pipe
E
2.5 2.5
G1/2"
With connection sets 31-32-33-34-43-44 Remark: flow and return can be reordered.
Dimensions in cm
Ø 27.8 31.3 34.8
C 7.4 10.8 14.4 D 14.2 15.7 17.7 E 7.7 9.6 11.5
E
2.5 2.5
G1/2"
With connection sets 41-42
25
Outputs
Standard delivery : - Circo Wall mounted model with
central connection MM underneath - wall fixing L - 2 chrome-plated air vents G 1/8”
Standard colours: - sandblast grey metallic 001 - white 301(RAL 9010 satin) - white 333(RAL 9016 satin)
H
code height length colour conn.
ORDERING CODE : CIRW. 180 027. XXX /MM
Iguana CIRW
H L 027 031 034
180 75/65/20 801 946 1092 90/70/20 1041 1229 1419 s o
192 75/65/20 854 1009 1164 90/70/20 1106 1307 1507 s o
200 75/65/20 887 1048 1209 90/70/20 1146 1354 1562 s o
220 75/65/20 961 1136 1311 90/70/20 1235 1460 1685 s o
240 75/65/20 1024 1210 1397 90/70/20 1309 1546 1785 s o
Output measured in accordance with EN442, at a water tempera-ture of 75/65 and a room tempe-rature of 20°C (ΔT=50).
Options Table in beech veneer
CODE Type
9087.012660 Circo ø 27 9087.012730 Circo ø 31 9087.012800 Circo ø 34
Large shelf in beech veneer
CODE Type
9087.010637 Circo ø 27 9087.010672 Circo ø 31 9087.010707 Circo ø 34
Small shelf in beech veneer Igua
na C
irco
Wal
l Mod
el
CODE Type
9087.011497 Circo ø 27 9087.011532 Circo ø 31 9087.011567 Circo ø 34
Towel rail chrome-plated aluminium
CODE Type
9087.013427 Circo ø 27 9087.013427 Circo ø 31 9087.013493 Circo ø 34
Hat rack chrome-plated aluminium
CODE Type
9087.014427 Circo ø 27 9087.014427 Circo ø 31 9087.014493 Circo ø 34
Connection set with guard (colour to match radiator)
CODE Ø st.
COIG.28L.DW.3... ... 27 COIG.28L.DC.3... ... 27
COIG.31L.DW.3... ... 31 COIG.31L.DC.3... ... 31 COIG.34L.DW.3... ... 34 COIG.34L.DC.3... ... 34
colour fill in sleeve coupling
Remark: For flow right (set 44), R instead of L. Ex. COIG.28R.DW.3.. ...
Flow left
TWO PIPE
Guard
DW
DC
Thermostatic head
43 Flow right
44
Price incl. thermostatic valve, lockshield and sleeve couplings. For connection to the wall: order 2 curves. Sleeve couplings for connection sets with cover plate see p.209. ATTENTION: floorboards need to be removed for the quard.
1
2
1. Iguana Circo Corner (at the top) 2. Iguana Circo Corner (below)
26
Iguana Circo Corner
27
28
Iguana Circo Corner18
.2
Dimensions ConnectionsCORW_Corner Wall Two pipe Standard connection
4 5 Code MM 18.2
air vent G 1/8”
M M
Notice To guarantee the output of the Iguana models and to limit the pressure drop, Jaga recommends the use of tube diameter 16/2, 18/1 or 18/2.
90° 27
.2
5.0
7.0
H
10.1
Top end connection Code 45 or 54 (1° number > flow) When ordering a top end con-nection, no insert pipe should be ordered. Air vents should be positioned on the central heating pipes. Ordering code: specify code 45 or 54 instead if MM, no sur-charge.
One pipe connection The standard radiator can be connected to a one pipe system with connection sets 41 or 42. With a maximum of 2 radiators per heating ring.
Dimensions options Large shelf
45.1
44
17
Small shelf
Position flow and return pipe
17.2 17.2
38.1
10
37
17.2 13
.7
13.7
5.0 G1/2"
17.2 13
.7
13.7
5.0 G1/2"
Towel rail
35.1
10
36
With connection sets 31-32-33-34 With connection sets 41-42 Hat rack
Remark: flow and return can be reordered.
36
35.1
10
29
Outputs
L
H
Standard delivery : - Circo Corner with central connection
MM underneath - wall fixing - 2 chrome-plated air vents G 1/8”
Standard colours: - sandblast grey metallic 001 - white 301(RAL 9010 satin) - white 333(RAL 9016 satin)
Options Large shelf in beech veneer
CODE
9087.040628
Small shelf in beech veneer
CODE
9087.041528
Igua
na C
irco
Cor
ner
Towel rail chrome-plated aluminium
CODE
9087.043466
Hat rack chrome-plated aluminium
CODE
9087.044466
code height length colour conn.
ORDERING CODE : CORW. 125 027. XXX /MM
Iguana CORW
Page
H L 027
125 75/65/20 723 90/70/20 952 s o
150 75/65/20 834 90/70/20 1100 s o
180 75/65/20 967 90/70/20 1277 s o
192 75/65/20 1021 90/70/20 1350 s o
200 75/65/20 1058 90/70/20 1399 s o
220 75/65/20 1149 90/70/20 1521 s o
240 75/65/20 1242 90/70/20 1646 s ot
Output measured in accordance with EN442, at a water tempera- ture of 75/65 and a room tempe-rature of 20°C (ΔT=50).
30
31
Iguana Aplano
Iguana Aplano Dimensions ConnectionsAPLW_Aplano Wall Two pipe Standard connection
4 5 Code MM
Top end connectionC
5.0
0.25 5.0 2.5
4.25 5.25 Code 45 or 54
(1° number > flow)32 8.1
4.5 When ordering a top end con-nection, no insert pipe should be ordered. Air vents should be
L
H
air vent G 1/8”
7.0 9.5
4.8
7.0
min. 10.0
10.1
0.6
positioned on the central heating pipes. Ordering code: specify code 45 or 54 instead if MM, no sur-charge.
M M One pipe connection The standard radiator can be connected to a one pipe system with connection sets 41 or 42. With a maximum of 2 radiators per heating ring.
Notice To guarantee the output of the Iguana models and to limit the pressure drop, Jaga recommends the use of tube diameter 16/2, 18/1 or 18/2.
Dimensions options
Large shelf
Aplano 30 41/52 63/74/85
L - 40.0 40.0 D - 26.1 26.1
D 17
5.0 L
G1/2" Small shelf
Aplano 30 41/52 63/74/85
L - 40.0 50.0 D - 19.1 19.1
1010
L
D
Dimensions in cm Towel rail
L 31 41 52 63 74 85
C 16.0 27.0 38.0 49.0 60.0 71.0
Aplano 30 41/52 63/74/85
L - 56.0 66.0 D - 15.8 15.8
D8
L
Hat rack
Aplano 30 41/52 63/74/85
L - 56.0 66.0 D - 15.8 15.8
8 L
D
Outputs Options
Standard delivery : Large shelf in beech veneer L
- Aplano with central connection MM underneath
- wall fixing - 2 chrome-plated air vents G 1/8”
Standard colours: - sandblast grey metallic 001
CODE For Aplano L
9087.030400 L 41-52-63-74-85 40
Small shelf in beech veneer
33 - white 301(RAL 9010 satin) - white 333(RAL 9016 satin)
Towel rail chrome-plated aluminium
CODE For Aplano L
9087.031400 L 41-52-63-74-85 40 9087.031500 L 52-63-74-85 50
Hat rack chrome-plated aluminium
CODE For Aplano L
9087.033560 L 41-52-63-74-85 56 9087.033660 L 52-63-74-85 66
code height length colour conn.
ORDERING CODE : APLW. 180 030. XXX /MM
Iguana APLW
H L 030 041 052 063 074 085
180 75/65/20 700 954 1208 1463 1717 1972 90/70/20 895 1219 1544 1870 2194 2520 s o
192 75/65/20 733 999 1265 1532 1798 2065 90/70/20 936 1276 1616 1957 2296 2637 s o
200 75/65/20 754 1028 1302 1576 1850 2124 90/70/20 962 1312 1662 2012 2362 2711
CODE For Aplano L
9087.034560 L 41-52-63-74-85 569087.034660 L 52-63-74-85 66
s ot
220 75/65/20 804 1097 1389 1681 1974 2266 90/70/20 1025 1399 1771 2144 2518 2890 s o
240 75/65/20 851 1161 1471 1780 2090 2399 90/70/20 1084 1479 1874 2268 2663 3056 s ot
H
Igua
na A
plan
o
Output measured in accordance with EN442, at a water tempera- ture of 75/65 and a room tempe- rature of 20°C (ΔT=50).
34
35
Iguana Arco
Iguana Arco Dimensions ConnectionsARCW_Arco Wall Two pipe Standard connection
4 5 Code MM
5.25 4.25
0.25 5.0
4.5
2.5
F
E
C
M M
When ordering a top end con-nection, no insert pipe should be ordered. Air vents should be air vent
G 1/8” positioned on the central heating pipes. Ordering code: specify code 45 or 54 instead if MM, no sur-charge.
One pipe connection The standard radiator can be connected to a one pipe system with connection sets 41 or 42. With a maximum of 2 radiators per heating ring.
Top end connection Code 45 or 54 (1° number > flow)
36 D
E
L
H
7.0
10.1
9.5
MIN 10
7.0
5.0
G1/2"
Notice To guarantee the output of the Iguana models and to limit the pressure drop, Jaga recommends the use of tube diameter 16/2, 18/1 or 18/2.
Dimensions options
Large shelf
Arco 29 41 51 62 73 83
L - 53.0 53.0 54.0 54.0 54.0 D - 28.9 30.5 30.0 31.5 33.5
D
L
17
Small shelf
Arco 29 41 51 62 73 83
L - 48.0 48.0 51.0 51.0 51.0 D - 21.9 23.5 23.0 24.5 26.5
L
10D
Dimensions in cm Towel rail
L 29.8 41.0 51.9 62.5 73.3 83.9
C 10.0 20.0 30.0 40.0 50.0 60.0 D 10.1 11.1 12.7 12.2 13.7 15.7
E 4.1 5.1 6.7 6.2 7.7 9.7 F 3.6 2.9 2.3 3.0 2.5 2.4
Arco 29 41 51 62 73 83
L - 55.0 55.0 66.0 66.0 66.0 D - 18.8 20.4 19.9 21.4 23.4
8D
Hat rack
Arco 29 41 51 62 73 83
L - 55.0 55.0 66.0 66.0 66.0 D - 18.8 20.4 19.9 21.4 23.4 L
8D
L
Outputs Options
Standard delivery Large shelf in beech veneer L - Arco with central connection MM
underneath- wall fixing - 2 chrome-plated air vents G 1/8”
Standard colours: - sandblast grey metallic 001
CODE For Arco L
9087.020529 L 41-51 53 9087.020543 L 62-73-83 54
Small shelf in beech veneer
37 - white 301(RAL 9010 satin) - white 333(RAL 9016 satin)
Towel rail chrome-plated aluminium
CODE For Arco L
9087.021480 L 41-51 48 9087.021512 L 62-73-83 51
Hat rack chrome-plated aluminium
CODE For Arco L
9087.023550 L 41-51 55 9087.023656 L 62-73-83 66
code height length colour conn.
ORDERING CODE : ARCW. 180 029. XXX /MM
Iguana ARCW
H L 029 041 051 062 073 083
180 75/65/20 791 1079 1366 1654 1941 2229 90/70/20 1011 1380 1747 2115 2482 2850 s o
192 75/65/20 813 1109 1404 1700 1995 2291 90/70/20 1039 1417 1794 2172 2549 2927 s ot
200 75/65/20 826 1127 1427 1727 2028 2328 90/70/20 1055 1439 1822 2205 2590 2973
CODE For Arco L
9087.024550 L 41-51 55 9087.024656 L 62-73-83 66
s ot
220 75/65/20 858 1170 1482 1794 2106 2418 90/70/20 1094 1492 1890 2288 2686 3084 s ot
240 75/65/20 886 1208 1530 1852 2174 2496 90/70/20 1129 1539 1949 2359 2770 3180 s o
H
Igua
na A
rco
Output measured in accordance with EN442, at a water tempera- ture of 75/65 and a room tempe- rature of 20°C (ΔT=50).
38
39
Iguana Visio
4.5
2.5 0.25
40
Iguana Visio Dimensions ConnectionsVISW_Visio Wall Two pipe Standard connection
4 5 Code MM
5.25 4.25
C
5.0
F
E
Top end connection Code 45 or 54 (1° number > flow) When ordering a top end con-D
nection, no insert pipe should be ordered. Air vents should be positioned on the central heatingair vent
0.5L 26.0
7.0 9.5
180
E
10.1
MIN 10
7.0 0.5
5.0
G1/2"
G 1/8” pipes.Ordering code: specify code 45 or 54 instead if MM, no sur-charge.
M M
One pipe connection The standard radiator can be connected to a one pipe system with connection sets 41 or 42. With a maximum of 2 radiators per heating ring.
Notice To guarantee the output of the Iguana models and to limit the pressure drop, Jaga recommends the use of tube diameter 16/2, 18/1 or 18/2.
Dimensions options
Large shelf
Visio 29 41 51 62 73 83
L - 53.0 53.0 54.0 54.0 54.0 D - 28.9 30.5 30.0 31.5 33.5 L
17D
Small shelf
Visio 29 41 51 62 73 83
L - 48.0 48.0 51.0 51.0 51.0 D - 21.9 23.5 23.0 24.5 26.5 LL
10D
Dimensions in cm
L 51.9 62.5 73.3
C 30.0 40.0 50.0 D 10.7 11.2 12.7
E 6.7 6.2 7.7 F 2.2 3.0 2.5
Towel rail
Visio 29 41 51 62 73 83
L - 55.0 55.0 66.0 66.0 66.0 D - 18.8 20.4 19.9 21.4 23.4
8D
Hat rack
Visio 29 41 51 62 73 83
L - 55.0 55.0 66.0 66.0 66.0 D - 18.8 20.4 19.9 21.4 23.4
8D
L
L
Outputs Options
Standard delivery : Large shelf in beech veneer - Visio with central connection MM L
underneath - wall fixing - 2 chrome-plated air vents G 1/8”
Standard colours: - sandblast grey metallic 001
CODE For Visio L
9087.020529 L 51 53 9087.020543 L 62-73 54
Small shelf in beech veneer
41 - white 301(RAL 9010 satin) - white 333(RAL 9016 satin)
H
Towel rail chrome-plated aluminium
CODE For Visio L
9087.021480 L 51 48 9087.021512 L 62-73 51
Hat rack chrome-plated aluminium
CODE For Visio L
9087.023550 L 51 55 9087.023656 L 62-73 66
code height length colour conn.
ORDERING CODE : VISW. 180 051. XXX /MM
Iguana VISW
H L 051 062 073
180 75/65/20 719 1007 1294 90/70/20 919 1288 1655 s o
200 75/65/20 751 1051 1352 90/70/20 959 1342 1726 s o
220 75/65/20 780 1092 1404 90/70/20 995 1393 1791 s o
Igua
na V
isio
CODE For Visio L
9087.024550 L 51 55 9087.024656 L 62-73 66
Output measured in accordance with EN442, at a water tempera-ture of 75/65 and a room tempe-rature of 20°C (ΔT=50).