Industrial Flowmeters

delt

aw

aveC

deltawaveC-P

Portable ultrasonic clamp-on

Flowmeter for liquids

Industrial Flowmeters

delt

aw

aveC

Background

• Since 1995: Supplier of ultrasonic clamp-on flowmeters

– 1995 - 2000: Controlotron– Since 2000: fuji Electric

• Since 2004: Manufacturer of ultrasonic open channel flowmeter deltawave

• Long-term experience with ultrasonic flowmeters– Power Plants– Water distribution– Waste water treatment– Chemistry and petrochemistry – Heating, Ventilation and air conditioning– Facility management– Water management

Industrial Flowmeters

delt

aw

aveC

Motivation

• Existing flowmeters

– Limitations• Temperatur• Additional measurement: Thermal output, heat rate

– Price / availability – Poor Handling / User-interface

Industrial Flowmeters

delt

aw

aveC

Measurement principle

cos221

)12(

TT

TTLv

4cos221

)12( 2D

TT

TTLQ

Prinzip der Laufzeitmessung

T1

L D

Ultrasonic transducers

T2

Flow velocity [m/s]

Flow [m3/s]

Industrial Flowmeters

delt

aw

aveC

Heat transfer measurement

)( kaltheißw TTcQQ Thermal output

Industrial Flowmeters

delt

aw

aveC

Specification

• Measurement principle: Ultrasonic transit-time (time-of-flight)• Physical quantities

– Flow Velocity– Flow and Volume– Thermal output and heat rate

• Accuracy: up to 1%

• Operational conditions– Temperatur: -40…150°C– Pipe Size: DN10….DN6000– Measurement range: -30….30 m/s

• Interfaces– 2x PT100 for heat transfer measurement– 2x 4…20mA Outputs (flow, velocity, thermal output….)– 1x Relay (Volume, alerts)– SD Data Loger (2 GB) for data logger– USB

Industrial Flowmeters

delt

aw

aveC

Case Histories (1)

• Customer: Waste water treatment plant• Application: Verification of DN800 magmeter in plant‘s inlet • Type of transducer: 500 kHz• Mounting: Z-Mode, Textile belts

Industrial Flowmeters

delt

aw

aveC

Case Histories (2)

• Customer: WWTP• Application: Sludge measurement DN300• Type of transducers: 1 MHZ• Mounting: V-Mode with spacer bar and chains

Industrial Flowmeters

delt

aw

aveC

Case Histories (3)

• Customer: Power plant• Application: Cooling water, DN1200• Type of transducers: 500 kHZ• Mounting: V-Modus, Textile belts

Industrial Flowmeters

delt

aw

aveC

Benefits

• Handling– Quick-Setup: < 1 Minute– Large clear-text-display, intuitive handling– Comprehensive data base for media/pipes

• Measurement accuracy: up to 1%

• Ultrasonic transducers / mounting– Easy and quick installation– Non-invasive, maintenance-free– No pressure loss, leakage-prove– Hygienic

• Built-in heat transfer measurement (standard)

• Applications– Pipe Size DN10…DN6000 with 3 types of transducers– High-temperature applications with standard transducers (150°C)