HEADQUARTERS - www.deltalight.com - USA - www.deltalight.us - CANADA - www.deltalight.ca
Installation instruction SPY CLIP HP
Application Ceiling semi recessed mounted
Finishing section to be used with DELTA LIGHT rough-in housing, plasterframe
or mounting kitFor indoor use only
Color FinishW - W = White cilinder - White ceiling plate
W - B = White cilinder - Black ceiling plate
B - B = Black cilinder - Black ceiling plate
Light sourceOne 18W POWERLED WHITE included
Power SupplyListed remote current controled class 2 power supply required (not supplied).
Max 500mA, typical forward voltage 34,4V.
Specification featuresPowder coated aluminum assembly
Pre-installed springs for easy installation
Suitable for dry or damp locations
DimensionsHeight: 111mm = 4”-3/8
Diameter: Ø62mm = Ø2”-7/16
Ceiling Cut out: 51mm = 2”
Required options for non-class 2 power limited circuitsHousing for IC and/or airtight applications
Plasterframe for IC applications
For remodel application414 90 01 MOUNTING KIT FLUSH SPY
Required accessories414 01 00 SPY TUBE
Accessories not supplied (option)413 03 01 HONEYCOMB 50
413 03 02 LINEAR SPREAD LENS 50
413 03 03 SPREAD LENS 50
413 03 04 SOFTENING LENS 50
413 03 05 GLASS SBL
SPY CLIP HP 83033
6 414 341 21 831
= B-B / W-B / W-W
SPY CLIP HP 82733
6 414 341 21 821
= B-B / W-B / W-W
SPY CLIP HP 93033
6 414 341 21 931
= B-B / W-B / W-W
SPY CLIP HP 92733
6 414 341 21 921
= B-B / W-B / W-W
2 = 3000K
3 = 2700K
Color temperature
35mm
1”-3/8
2mm
1/16"
111mm
4”-3/8 Ø62mm
Ø2”7/16
Ø58mm
Ø2”-5/16
355°
90°
1 - Bar hangers standard0 - No bar hangers
1 - 120V2 - 277V3 - 120-277V
Range Installation type
Voltage Mounting Option
202
202
6
6
87 Plate D50
95 ( Flush !nish)
1 - Bar hangers standard
1 - Bar hangers standard
06 - IC Plasterframe S
06 - IC Plasterframe S
00 -
00 -
0
0
Power & Dimming Opening
OR
OR
7 - IC AT Housing S
7 - IC AT Housing S
6
6
202
202
00 -
00 -
87 Plate D50
95 ( Flush !nish)
0
0
1 - Bar hangers standard
1 - Bar hangers standard
1 - Bar hangers standard0 - No bar hangers
1 - 120V2 - 277V3 - 120-277V
Range Installation type
Power & Dimming Opening
Voltage Mounting Option
Conforms to ANSI/UL Std. 2108
Cert. to CAN/CSA Std. 22.2 No. 250.0
ICICAT
Last Update ALLU 19/12/2017
Installation instruction
2
NORTH AMERICAN EDITION
HEADQUARTERS - www.deltalight.com - USA - www.deltalight.us - CANADA - www.deltalight.ca
A
B
A
B
SAVE!
B
A
INSTALLATION LUMINAIRE
SPY CLIP HP
if not installed in a class 2 power limited circuit
ICAT
HOUSING PLASTERFRAME
Not Supplied Rough-in Housing or Plasterframe
Required
Accessories
MOUNTING KIT
1X2X
RED
1
4
5
3
2+ +
- -
+
+
--
1 UNIT
+
+
-
-
i
+ -
+
>1 UNIT
ELECTRICAL CONNECTION
+ +- - -...
6
CAUTION!
CLASS 2 POWER LIMITED CIRCUITS ONLY
ATTENTION!
SEULEMENT POUR RESEAUS CLASS 2,
A PUISSANCE LIMITE
MAX 500mA DC (red/rouge: +, black/noir: -)
IC IC
3
NORTH AMERICAN EDITION
HEADQUARTERS - www.deltalight.com - USA - www.deltalight.us - CANADA - www.deltalight.ca
Installation instruction
INSTALLATION LUMINAIRE
SPY CLIP HP
8 9
on
o�
10
355°
90
- Use only power supplies that are certi�ed according to the applicable IEC or UL safety standards.
- Use only SELV power supplies.
- Check the ratings of the power supply with those of the luminaire.
The maximum current rating must be taken into account.
The indicated typical voltage must not be used to select a constant voltage power supply but is indented to used
to select a constant current power supply that is able to cover that typical voltage.
- Take appropriate ESD measures. Avoid touching bare conductors.
- Leds or led luminaires that require a current controlled power supply must never be connected in parallel.
- Leds can be damaged by the contact with certain chemicals or chemical gasses.
Therefore led domes or led engines should never be cleaned with chemical substances.
The following substances have proven to have a negative in�uence on the performance and
must not be used in the direct environment of a led luminaire.
Methyl acetate or ethyl acetate (i.e., nail polish remover)
Cyanoacrylates (i.e., “Superglue”)
Glycol ethers (including Radio Shack® Precision Electronics Cleaner - dipropylene glycol monomethyl ether)
Formaldehyde or butadiene (including Ashland PLIOBOND® adhesive)
Dymax 984-LVUF conformal coating
Loctite Sumo Glue
Gorilla Glue
Bleach, Bleach-containing cleaners, sprays
Loctite 384 adhesive
Loctite 7387 activator
Loctite 242 threadlocker
- Remove insulation and/or provide su�cient ventilation so that the indicated max Tc is not surpassed.
- Leds are susceptible to switching transients. Therefore switching must be done in the primary circuit
of the power supply.
- DELTA LIGHT recommands to use the power supplies that are indicated in the Lighting Bible.
- Respect polarity
- Don’t test LED luminaires one by one on a powersupply that is switched on.
DO NOT TOUCH OR CLEAN THE LED ARRAY!
!
ACCESSORIES
2 3Used as
replacement
lens
1
HONEYCOMB 50
413 03 01
LINEAR SPREAD LENS 50
413 03 02
SPREAD LENS 50
413 03 03
SOFTENING LENS 50
413 03 04
GLASS SBL 50
413 03 05
SPY TUBE
414 01 00
Click!!
FLAT SIDE
ROUGH SIDE
SPY TUBE
414 01 00
Click!!
NO SECONDARY SWITCHING
AC DC
AC DC
ATTENTION
OBSERVE PRECAUTIONS FOR
HANDLING ELECTROSTATIC
DISCHARGE SENSITIVE
DEVICES
top related