DESCRIPTION

The GENEX Assistant is excellent software tool for Post-Processing 2G & 3G Drive Test Data. With the GENEXAssistant, you can:  Have a panorama view of network performance  Locate network troubles  Improve network quality  Verify network planning and optimization ANALYSIS OF LOGFILE FOR POST PROCESSING OF LOGFILE IN GENEX ASSISTANCE WE NEED TO OPEN A NEW PROJECT

TRANSCRIPT

1

BY

IMRAN HASHMI

INTRODUCTION

TO

GENEX ASSISTANT

2

The GENEX Assistant is excellent software tool for

Post-Processing 2G & 3G Drive Test Data.

With the GENEX Assistant, you can:

ØHave a panorama view of network performance

ØLocate network troubles

ØImprove network quality

ØVerify network planning and optimization

3

Functions of the Genex Assistant

Analyzing the test data in WCDMA GSM dual mode

The Assistant analyzes the test data in the WCDMA and GSM networksThe Assistant also has the independent display systems for separately displaying the engineering parameters and real-time data

Test data playback

The Assistant supportsØManual or automatic play of the test dataØDisplay of measurement parameters for trouble spots in detailØNetwork problems locating in a quick manner

4

FOR POST PROCESSING OF LOGFILE IN

GENEX ASSISTANCE WE NEED TO

OPEN A NEW PROJECT

ANALYSIS OF LOGFILE

5

NEW PROJECT

STEP-1 PROJECT NAME ( TEST 01 )

STEP-2 PROJECT PATH ( LOCATION TO SAVE THE PROJECT )

STEP-3 MAP PATH ( Insert the Map from the Location )

STEP-4 DATASET NAME ( LOGFILE NAME )

6Huawei TECHNOLOGIES Co., Ltd. Huawei Confidential

Opening a New Project

7Huawei TECHNOLOGIES Co., Ltd. Huawei Confidential

Project Path to Save It

8Huawei TECHNOLOGIES Co., Ltd. Huawei Confidential

Log file Name

9

ANALYSIS LOG FILE IMPORTING

Step 1 Select a dataset from the Project tab in the navigation view

Step 2 Right-click the dataset and choose Import Test Data Import GENEX Probe on the shortcut menu

Step 3 In the Import GENEX Probe log File as shown below

10Huawei TECHNOLOGIES Co., Ltd. Huawei Confidential

Import the Type of Log File

11Huawei TECHNOLOGIES Co., Ltd. Huawei Confidential

CLICK BROWSE FOR LOGFILE LOCATION

12

COMBINE DATA ANALYSIS

ASSISTANCE CAN SUPPORT IMPORTING MORE THAN ONE LOG FILE AS IT COMBINES THESE DEVICES AND RE-ANALYZE THE EVENTS

Step 1 Select a dataset from the Project tab in the navigation view

Step 2 Choose Dataset > Combine Device > Combine UE

Step 3 Select multiple devices from PreCombine in the displayed Combine Device

13Huawei TECHNOLOGIES Co., Ltd. Huawei Confidential

14Huawei TECHNOLOGIES Co., Ltd. Huawei Confidential

New Combined Log file

15Huawei TECHNOLOGIES Co., Ltd. Huawei Confidential

16

IMPORTING THE MAP DATA

ØVECTOR

ØPLACES

ØCLUTTER

Step 1 Select the Map Layer Window and right click.

Step 2 Select the location for the data to import.

17Huawei TECHNOLOGIES Co., Ltd. Huawei Confidential

Layer Control

18

Viewing Test Data in Different Formats

Following are the types that the Test Data can be Displayed

ØDISPLAY ON MAP

ØDISPLAY ON SHEET

ØDISPLAY ON CHATR

ØDISPLAY ON PIE

ØDISPLAY ON Histogram

19

Step 1 Select Any of the parameter to display in the Window by right clicking on it

Step 2 Select the type of display format.

20Huawei TECHNOLOGIES Co., Ltd. Huawei Confidential

Step 01

Step 02

DISPLAY ON MAP

21Huawei TECHNOLOGIES Co., Ltd. Huawei Confidential DISPLAY ON CHART

22Huawei TECHNOLOGIES Co., Ltd. Huawei Confidential DISPLAY ON PAI

23Huawei TECHNOLOGIES Co., Ltd. Huawei Confidential

DISPLAY ON HOLOGRAM

24Huawei TECHNOLOGIES Co., Ltd. Huawei Confidential

DISPLAY ON SHEET

25Huawei TECHNOLOGIES Co., Ltd. Huawei Confidential

Filtering Test DataThe Assistant can filter the imported data. This feature is capable of comparing the data and executing some simple logical calculations.

To filter test data, perform the following steps:

Step 1 Select a dataset from the Project tab in the navigation view.

Step 2 Choose Dataset > Filter Imported Data

26Huawei TECHNOLOGIES Co., Ltd. Huawei Confidential

27Huawei TECHNOLOGIES Co., Ltd. Huawei Confidential

Select the Desired Filter

Click on Insert

Click on Excute

28

Introduction to Engineering Parameters Engineering parameter fields

Whether Mandatory to Be Filled InRemarksField

NoAntenna altitudeAltitude

NoAntenna ground heightGround Height

YesLocation Area CodeLAC

YesCell ID CI

NoDown tilt angle (°C)Down Tilt

YesAzimuth (°C)Azimuth

YesLatitude (decimal)Latitude

YesLongitude (decimal)Longitude

29

Perform the following steps to import Engineering Parameters

Step 1 Select a dataset from the Project tab in the navigation view.

Step 2 Choose Dataset > Import Engineering Parameter, and select WCDMA or GSM based on the test data.

Step 3 In the displayed dialog box, perform the following operations

Open the Excel file for saving the engineering parameters.Select the sheet for displaying the engineering parameters.

Step 4 Click OK.

30

If all the fields in the sheet can match the parametersthe Assistant automatically imports the engineering parameters

If no field in the sheet can match the parameters

Step 5 Match the missing engineering parameter fields one by one.For details, refer to description of button functions

Step 6 Click the button to import the data.After the data is imported, the site data is automatically displayed on the map.

31Huawei TECHNOLOGIES Co., Ltd. Huawei Confidential

Step:01 Click on Dataset Name

Step:02

Select Type

32Huawei TECHNOLOGIES Co., Ltd. Huawei Confidential

Step:03 Open the Table

Step:04 Import the Excel file

33Huawei TECHNOLOGIES Co., Ltd. Huawei Confidential

Engineering Parameters Display

Engineering Parameters Display

34

DRIVE TEST PLOTS

RX LEVEL PLOT

v RXLEVEL FULL

v RXLEVEL SUB

35Huawei TECHNOLOGIES Co., Ltd. Huawei Confidential

36

RX QUALITY PLOT

vRX QUAL FULL

v RX QUAL SUB

37Huawei TECHNOLOGIES Co., Ltd. Huawei Confidential

38

OTHER DIFFERENT TYPE

OF PLOTS

39Huawei TECHNOLOGIES Co., Ltd. Huawei Confidential BCCH PLOT

40Huawei TECHNOLOGIES Co., Ltd. Huawei Confidential BSIC PLOT

41Huawei TECHNOLOGIES Co., Ltd. Huawei Confidential FER PLOT

42Huawei TECHNOLOGIES Co., Ltd. Huawei Confidential C/I PLOT

43Huawei TECHNOLOGIES Co., Ltd. Huawei Confidential HANDOVER PLOT

44

GSM DRIVE TEST STATISTICS

GENEX ASSISTANCE CAN PROVIDE THE DETAIL REPORT OF THE DRIVE TEST

ØReport: WCDMA Scanner Neighbor Cell

ØReport: WCDMA Scanner Handover Statistic

ØReport: WCDMA UE Call Setup

ØReport: WCDMA UE Call Statistics

45

ØReport: WCDMA UE Call Timing Analysis

ØReport: WCDMA UE Crossingtable HSDPA

ØReport: WCDMA UE RRC Setup Statistics

ØReport: GSM Drive Test Statistics

ØReport: GSM UE Call Statistics Analyse

ØReport: GSM Handover Statistic

46Huawei TECHNOLOGIES Co., Ltd. Huawei Confidential

47

GSM DRIVE TEST STATISTICS

The GSM Drive Test Statistics report provides the statistics on RXlevel, voice quality, and so on, as listed in Table

Number of data points in each scope of call setup duration as per callØCall Setup Time

Number of data points in each TA scopeØTA

Statistics on quality and distanceØRxQual

Distance values for RX level > 90 dBm and RX level < 90 dBmØRxLev as Distance

RX level in connected or idle stateØBCCH RxLev

RX level in connected stateØRxLev

DescriptionItem

48

-67.18560618.10Total

-101.00120.17 %0.03-120 to -100

-92.67330.61 %0.11-100 to -90

-83.485488.40 %1.52-90 to -80

-75.06186130.66 %5.55-80 to -70

-59.30315260.22 %10.90-70 to -10

AvgTotal Count%Distance(km)RxLev_Sub(dBm)

RxLev_Sub(dBm)

4918.105606Total

73.77 %13.3580.11 %449103.99 %0.723.62 %20312.61 %0.472.16 %12125.11 %0.923.42 %19233.40 %0.622.80 %15743.45 %0.622.55 %14353.33 %0.602.60 %14664.35 %0.792.73 %1537

%Distance(km)%CountRxQual sub

RxQual_Sub

50

0.14Average86.70 %47850 to 112.47 %6881 to 20.74 %412 to 30.09 %53 to 40.00 %04 to 50.00 %05 to 100.00 %010 to 320.00 %032 to 63

%CountTA

Number of data points in each TA Scope

51Huawei TECHNOLOGIES Co., Ltd. Huawei Confidential 4.5028Total

0.000.00 %0x>=20s0.000.00 %015s<=x<200.000.00 %012s<=x<15s0.000.00 %010s<=x<12s0.000.00 %08s<=x<10s7.003.57 %16s<=x<8s4.5475.00 %214s<=x<6s3.9321.43 %62s<=x<4s0.000.00 %00s<=x<2s

Avg%CountTimeCall Setup Time (Alerting - ChannelReq )

CALL SETEUP TIME

52

Microsoft Excel Worksheet

ØRxQual

ØCall Setup Time

ØTA

ØRxLev_Sub + RxLev_Idle(dBm)

REPORTS IN DEATAIL

Huaw Confidential

53

ØGSM MS Call Analysis

ØGSM MS Call Statistics

ØGSM MOS Statistics

REPORTS IN DEATAIL

Microsoft Excel Worksheet

54

THANK YOU