kone 2010 architectural planning guide
Post on 04-Apr-2015
485 Views
Preview:
TRANSCRIPT
Architectural
Planning Guide
2010
2 KONE Architectural Planning Guide
Redefining Elevator TechnologyKONE EcoDisc®
Proven Technologyn More than 10 years of experience with EcoDisc technology,
including the world’s first Machine Room-Less (MRL) installation
n Over 250,000 MRL installations worldwide
n Applicable from 2 to 100+ floors
Space Savingsn In low- to mid-rise elevators, the compact EcoDisc structure eliminates
the traditional machine room
n In high-rise systems, the EcoDisc delivers remarkable space savingsand improved efficiency
MRL
Machine Room-Less
MR
Machine Room Above
KONE Eco-efficient™ solutionsHow much can you save by selecting right?
KONE elevators can reduce the total energy consumption by as much
as two-thirds or even more. For example, a KONE EcoSpace elevator,
with the KONE EcoDisc hoisting machine, uses up to 70% less energy
compared to a hydraulic elevator and up to 50% less than a 2-speed
traction. With additional energy-saving features, this energy
consumption can be reduced still further.
1
2
3
4
A green hoisting system
The KONE EcoDisc hoisting machine made DC gearless and
inefficient geared hoisting machines obsolete. The KONE EcoDisc
permanent-magnet synchronous machine, together with a vector-
controlled drive system and regenerative options, provide the highest
total efficiency and minimize both mechanical and electrical losses.
Regenerative drive
When the car is going down with a heavy load, it contains potential
energy. The regenerative drive recovers this energy. It can save up to
25% of the energy consumed by a typical 14-person KONE
EcoSystem MR elevator.
Put to sleep when not in use
In today’s elevators, lights, signalization and ventilation can consume
a considerable amount of electricity even when the elevator is not
moving. KONE energy-efficient options supervise elevator usage and
set the devices to sleep mode during inactive periods to minimize
total energy consumption.
Eco-efficient car lighting
To save energy used for car lighting, halogen lights have been
replaced by LED spot lights. LED lights consume 80% less electricity
than halogen lights and last up to 10 times longer.
1
2
3
4
EcoDisc Applications
3KONE Architectural Planning Guide
Select your EcoDisc-powered elevator
Application Low-Rise
Type MRL
Powered by EcoDisc
Capacity 2000 – 5000 lb (907 – 2268 kg)
Speed 150 fpm (.75 m/s)
Landings 2 to 10
Machine Room-Less performance in a new or existing
hoistway: Designed specifically to fit in the hydraulic
footprint, KONE EcoSpace delivers pure traction
Machine Room-Less performance to low-rise buildings.
n No oiln No hole drillingn Uses 70% less energy than hydraulic applicationsn Minimal building interfacen Ideal solution for replacement of existing hydraulic
elevator (contact KONE Sales Professional)
Application High-Rise
Type MR
Powered by EcoDisc
Capacity 2000 – 8000 lb (907 – 3629 kg)
Speed 700 – 1600 fpm (3.5 – 8.13 m/s)
Landings 6 to 126
State-of-the-art technology, a truly extraordinary
elevator system: KONE Alta elevators are developed
for the next generation of super-tall buildings of up
to 1600 ft (480 m) in height.
n Reaches speeds of up to 1600 fpm (8.13 m/s)n Super efficientn High power-to-weight ratio
The special Silent Car™ technology applied on bothsingle and high capacity double-decker cars ensuresa smooth and quite ride.
KONE Alta
KONE EcoSpace
For the latest product information and interactive design tools, visit www.us.kone.com
Application Mid-Rise
Type MRL
Powered by EcoDisc
Capacity 2000 – 5000 lb (907 – 2268 kg)
Speed 200 – 500 fpm (1.0 – 2.54 m/s)
Landings 6 to 27
The Machine Room-Less solution that launched
a revolution: Introduced over a decade ago, KONE
MonoSpace forever changed the vertical
transportation landscape by eliminating the
requirement for a machine room.
n Consumes approximately 50% less energy than
conventional traction machinesn Creates more usable space – variable machine
locationsn Superior ride qualityn Minimal building interface
KONE MonoSpace
Application Mid- to High-Rise
Type MR
Powered by EcoDisc
Capacity 2000 – 5000 lb (907 – 2268 kg)
Speed 200 – 700 fpm (1.0 – 3.5 m/s)
Landings 6 to 63
Innovative, space efficient, mid-high rise system:
KONE EcoSystem MR elevators use next-generation
KONE EcoDisc hoisting machines that require only
half the overhead machine room space of traditional
traction elevators.
n Energy efficientn Superior acceleration/deceleration profilen Improved floor-floor times and leveling
KONE EcoSystem MR
KONE Architectural Planning Guide4
Co
ntr
ol
Sp
ace
CAPACITY LBS (kg) CONTROLLER SPACE WIDTH (mm) DEPTH (mm) DOOR WIDTH (mm)
2000 to 3500 integral or remote closet 3'-8" 1'-8" 3'-0"(907 to 1588) (1118) (508) (914)
4000 to 5000 integral or remote closet 4'-2" 1'-8" 3'-6"(1814 to 2268) (1270) (508) (1067)
2000 to 5000 adjacent room 5'-0" dimension (B) 3'-0"(907 to 2268) (1524) (914)
SERV
ICE
PASSEN
GER
Fro
nt
& R
evers
e O
pen
ing
Fro
nt
Op
en
ing
2000 (907) SSP 7'-4" (2235) 6'-31⁄4" (1911) 5'-8" (1727) 4'-3" (1295) 3'-0" (914)
2500 (1134) SSP-CO 8'-4" (2540) 6'-31⁄4" (1911) 6'-8" (2032) 4'-3" (1295) 3'-6" (1067)
3000 (1361) SSP-CO 8'-4" (2540) 6'-11" (2108) 6'-6" (1981) 5'-0" (1524) 3'-6" (1067)
3500 (1588) SSP-CO 8'-4" (2540) 7'-51⁄4" (2267) 6'-6" (1981) 5'-63⁄16" (1681) 3'-6" (1067)
4000 (1814) CO 9'-4" (2845) 7'-51⁄4" (2267) 7'-513⁄16" (2281) 5'-63⁄16" (1681) 4'-0" (1219)
4000 (1814) 2SP 7'-4" (2235) 10'-11⁄2" (3086) 5'-63⁄16" (1681) 7'-7 7⁄16" (2323) 4'-0" (1219)
4500 (2041) 2SP 7'-4" (2235) 10'-7 1⁄2" (3238) 5'-63⁄16" (1681) 8'-13⁄8" (2473) 4'-0" (1219)
5000 (2268) 2SP 7'-4" (2235) 11'-31⁄4" (3435) 5'-63⁄16" (1681) 8'-93⁄16" (2672) 4'-0" (1219)SERV
ICE
PASSEN
GER
CAPACITY OPENING HOISTWAY HOISTWAY INTERIOR INTERIOR DOORLBS (kg) TYPE WIDTH (mm) DEPTH (mm) WIDTH (mm) DEPTH (mm) WIDTH (mm)
2000 (907) SSP 7'-4" (2235) 5'-9" (1753) 5'-8" (1727) 4'-3" (1295) 3'-0" (914)
2500 (1134) SSP-CO 8'-4" (2540) 5'-9" (1753) 6'-8" (2032) 4'-3" (1295) 3'-6" (1067)
3000 (1361) SSP-CO 8'-4" (2540) 6'-3" (1905) 6'-6" (1981) 5'-0" (1524) 3'-6" (1067)
3500 (1588) SSP-CO 8'-4" (2540) 6'-11" (2108) 6'-6" (1981) 5'-63⁄16" (1681) 3'-6" (1067)
4000 (1814) CO 9'-4" (2845) 6'-11" (2108) 7'-513⁄16" (2281) 5'-63⁄16" (1681) 4'-0" (1219)
4000 (1814) 2SP 7'-4" (2235) 9'-2" (2794) 5'-63⁄16" (1681) 7'-7 7⁄16" (2323) 4'-0" (1219)
4500 (2041) 2SP 7'-4" (2235) 9'-8" (2946) 5'-63⁄16" (1681) 8'-13⁄8" (2473) 4'-0" (1219)
5000 (2268) 2SP 7'-4" (2235) 10'-21⁄4" (3105) 5'-63⁄16" (1681) 8'-93⁄16" (2672) 4'-0" (1219)
EcoSpace A B C D E
J K L
Notes
(1) A hoist beam (by KONE) is required for installation (by
others). Dimension reflects clear under hoist beam.
(2) If an EBD (Emergency Battery Device) is required please
contact your KONE Sales Professional for further detail
regarding dimension .
(3) The published hoistway x dimensions represent
the minimum clear inside requirements. Construction
efficiencies can be realized by increasing these
dimensions by up to 2" (51 mm).
(4) For seismic zones, add 4" (102 mm) to dimension
for 2000 lb (907 kg) and 2500 lb (1134 kg) capacity
applications.
(5) For pit depths less than 5' (1524 mm) please contact a
KONE Sales Professional.
(6) No occupied space below the pit is allowed with
EcoSpace.
(7) All dimensions are based on an 8'-0" (2438 mm) cab
with a 7'-0" (2134 mm) door. Alternate car and door
heights are available, but will affect dimension .
(8) Contact your local KONE Sales Representative regarding
local code variations when utilizing the integral and
remote closet options.
Visit www.us.kone.com for the latest job-specific details,
CAD drawings, specifications, electrical data, reaction loads,
cab designer tool and building access requirements.
BH
A
A
J
H
KONE EcoSpace MAX TRAVEL
83 ft (25 m)
MAX LANDINGS
10
SPEED
150 fpm (.75 m/s)
CAR HEIGHT
8, 9 or 10 ft
(2438, 2743
or 3048 mm)
ENTRANCE HEIGHT
7, 8 or 9 ft
(2134, 2438
or 2743 mm)
MINIMUM
OVERHEAD HEIGHT
13 ft (3962 mm)
PIT DEPTH
5 ft (1524 mm)
F
G
H
I
Plan ViewsSection ViewRemote Control
Closet(option 1)
Adjacent orRemote Control
Room(option 2)
Integral Controller Space (standard)
(3)
(3) (4)
A
C
D
K
B
B
L
K
LJ
J
L
J
E
H F G
TRAVEL G
I(5)
(1)
KONE Architectural Planning Guide 5
KO
NE E
coSp
ace
K
ON
E M
on
oSp
ace
KO
NE E
coSyste
m M
RK
ON
E A
lta
1
2
3
4
5
6
Space Efficiency
Possibility to accommodate reduced headroom height and pit depth. The KONE EcoDisc
machine is so compact there is no need for a machine room above, as it fits right into
the hoistway.
Energy-efficient
The revolutionary gearless KONE EcoDisc machine has only one moving part and is three
times more efficient than a hydraulic-powered unit using 70% less energy – with the
potential to cut annual operating costs in half or better – a true energy miracle.
Minimal Disruption
EcoSpace EB fits inside the existing hydraulic hoistway, minimizing the need for modifications.
Reusable Entrances
KONE EcoSpace EB reduces significant structural modifications by seamlessly interfacing
with most existing hydraulic entrances.
Modern, Code-compliant
Modern, simple and code-compliant operating displays.
High Performance
Optimal stopping accuracy for a smooth ride.
No Oil
The hydraulic cylinder is drained of all oil and capped, ensuring oil free, environmentally-
friendly operation.
KONE EcoSpace is also applicable for
existing buildings with hydraulic
elevators. This turnkey solution
replaces the hydraulic system with
innovative MRL technology.
Why Replace?
Instead of replacing your old elevators
with similar technology, KONE offers
you a new choice. Our innovative
Machine Room-Less design is the first
turnkey full replacement elevator
solution for existing hydraulic
elevators. Thanks to the revolutionary
KONE EcoDisc motor, EcoSpace EB
fits into the existing hydraulic hoistway
with capability to seamlessly interface
with your existing entrances.
KONE has sold over 250,000 Machine
Room-Less elevators globally, with an
excellent record of operating reliability.
So, instead of complicated, lengthy
and expensive retrofit upgrades,
KONE provides a brand new elevator.
n Everything from the site survey to
the dismantling of the existing
equipment is carefully thought out
in order to minimize disruption to
your building.
n Our optimized maintenance program
minimizes downtime and ensures safe
and reliable lifetime operation.
EcoSpace EB Advantagesn For the owner: Minimized building
disruption, increased property value,
accommodates reduced pit depth
and overhead
n For the tenant: Smoother, quieter
ride, no hydraulic oil odor, optimum
stopping accuracy, sophisticated car
features
n For the environment: No hydraulic
oil, energy-efficient, recycle existing
elevator where feasible, minimize
building materials
KONE EcoSpace EB™
The Benefits are Clear
2
3
4
5
6
7
1
7
6 KONE Architectural Planning Guide
2000 (907) 7'-9" (2362) 13'-5" (4089) 9'-0" (2743) 13'-10" (4216) 8'-8" (2642) 13'-10" (4216)
2500 (1134) 6'-9" (2057) 13'-5" (4089) 8'-1" (2464) 13'-10" (4216) 7'-10" (2388) 13'-10" (4216)
3000 (1361) 6'-9" (2057) 13'-5" (4089) 8'-1" (2464) 13'-10" (4216) 7'-10" (2388) 13'-10" (4216)
3500 (1588) 6'-9" (2057) 13'-5" (4089) 8'-1" (2464) 13'-10" (4216) 7'-10" (2388) 13'-10" (4216)
4000 (1814) 6'-9" (2057) 13'-5" (4089) 8'-7" (2616) 13'-10" (4216) 8'-4" (2540) 13'-10" (4216)
2000 (907) SSP 7'-4" (2235) 6'-8" (2032) 5'-81⁄2" (1740) 4'-3
1⁄4" (1302) 3'-0" (914)
2500 (1134) SSP-CO 8'-4" (2540) 6'-8" (2032) 6'-81⁄2" (2045) 4'-3
1⁄4" (1302) 3'-6" (1067)
3000 (1361) SSP-CO 8'-4" (2540) 7'-2" (2184) 6'-81⁄2" (2045) 4'-9
1⁄4" (1454) 3'-6" (1067)
3500 (1588) SSP-CO 8'-4" (2540) 7'-10" (2388) 6'-81⁄2" (2045) 5'-5
1⁄4" (1657) 3'-6" (1067)
4000 (1814) CO 9'-4" (2845) 7'-10" (2388) 7'-81⁄2" (2350) 5'-5
1⁄4" (1657) 4'-0" (1219)
2000 to 4000 integral or remote cabinet 4'-2" 1'-8" 3'-6"
(907 to 1814) (1270) (508) (1067)
2000 to 4000 adjacent or remote room 5'-0" dimension (B) 3'-0"
(907 to 1814) (1524) (914)
KONE MonoSpace Planning Guide:Machine at Rear Configuration – Optimizes Space (Available in passenger shape with front opening option)
MAX TRAVEL 230 ft. (70.1 m)
MAX LANDINGS 36
SPEED 200, 350, 500 fpm
(1.00, 1.78, 2.54 m/s)
CAR HEIGHT8, 9 or 10 ft. (2438, 2743 or 3048 mm)
ENTRANCE HEIGHT7, 8 or 9 ft. (2134, 2438 or 2743 mm)
F
G
Notes(1) Shallower Pit Depths may be available per
specific applications. Contact your KONESales Professional for further information.
(2) Buffer service platforms are required whenpit depth exceeds 8'-6" (2590 mm).
(3) Hoist beams (by KONE) are required forinstallation (by others). Dimension reflectsclear under hoist beam.
(4) If occupied space exists below the hoistway,consult your KONE Sales Professional.
(5) All dimensions are based on an 8'-0"(2438 mm) cab with a 7'-0" (2134 mm) door. Alternate car and door heights are available, but will affect dimension .
(6) For seismic applications (zone 2 or greater)add 4" (102 mm) to hoistway width and 13"(330 mm) to the pit depth.
(7) If an EBD (Emergency Battery Device) isrequired, please contact your KONE SalesProfessional for further detail regardingdimension .
(8) Contact your local KONE Sales Representativeregarding local code variations when utilizingthe integral and remote closet options.
H
HVisit www.us.kone.com for the latest job-
specific details, CAD drawings, specifications,
electrical data, reaction loads, cab designer
tool and building access requirements.
J
7KONE Architectural Planning Guide
KO
NE E
coSp
ace
K
ON
E M
on
oSp
ace
KO
NE E
coSyste
m M
RK
ON
E A
lta
Integral Controller Space (standard)
(6)
A
C
D
K
B
LJ
E
(7)
Adjacent orRemote Control Room
(option 2)
B
L
J
(7)
Remote Control Closet(option 1)
K
LJ
(7)
(3)
(1) (2) (6)
H F G
G
I
(4)
(5)
TRAVEL
Plan Views
Section View
8 KONE Architectural Planning Guide
Notes(1) Shallower Pit Depths may be available per
specific applications. Contact your KONE SalesProfessional for further information.
(2) Buffer service platforms are required when pitdepth exceeds 8'-6" (2590 mm).
(3) A hoist beam (by KONE) is required forinstallation (by others). Dimension reflectsclear under hoist beam.
(4) If occupied space exists below the hoistway, consult your KONE Sales Professional.
(5) All dimensions are based on an 8'-0" (2438mm) cab with a 7'-0" (2134 mm) door.Alternate car and door heights are available,but will affect dimension .
(6) For 2000 lb (907 kg) capacity maximum travel= 90' (27.4 m) and maximum openings = 10.
(7) For 2500 lb – 5000 AIA (1134 kg – 2268 kg)capacity maximum travel = 230' (70 m) andmaximum openings = 36 with 4'-0" dooroption on 5000 and 5000 AIA capacities. If5000 and 5000 AIA capacities feature a 4'-6"door the maximum openings = 18.
(8) For front opening seismic applications (zone 2or greater) add 4" (102 mm) to hoistwaywidth and 3" (76 mm) to hoistway depth.
(9) For front and reverse opening seismic applications (zone 2 or greater) add 4" (102 mm) to hoistway width.
(10) If an EBD (Emergency Battery Device) isrequired, please contact your KONE SalesProfessional for further detail regardingdimension .
(11) Contact your local KONE Sales Representativeregarding local code variations when utilizingthe integral and remote closet options.
Visit www.us.kone.com for the latest job-specific details, CAD drawings, specifications,electrical data, reaction loads, cab designertool and building access requirements.
H
H
J
2000 to 5000 AIA integral or remote cabinet 4'-2" 1'-8" 3'-6"
(907 to 2268) (1270) (508) (1067)
2000 to 5000 AIA adjacent or remote room 5'-0" dimension (B) 3'-0"
(907 to 2268) (1524) (914)
2000 (907) SSP 8'-0" (2438) 6'-4" (1930) 5'-81⁄2" (1740) 4'-3
1⁄4" (1302) 3'-0" (914)
2500 (1134) SSP-CO 9'-5" (2870) 6'-10" (2083) 6'-81⁄2" (2045) 4'-3
1⁄4" (1302) 3'-6" (1067)
3000 (1361) SSP-CO 9'-5" (2870) 7'-1" (2159) 6'-81⁄2" (2045) 4'-9
1⁄4" (1454) 3'-6" (1067)
3500 (1588) SSP-CO 9'-5" (2870) 7'-5" (2261) 6'-81⁄2" (2045) 5'-5
1⁄4" (1657) 3'-6" (1067)
4000 (1814) CO 10'-5" (3175) 7'-5" (2261) 7'-81⁄2" (2350) 5'-5
1⁄4" (1657) 4'-0" (1219)
2500 (1134) SSP-CO 9'-5" (2870) 7'-1" (2159) 6'-81⁄2" (2045) 4'-3
3⁄4" (1314) 3'-6" (1067)
3000 (1361) SSP-CO 9'-5" (2870) 7'-6" (2286) 6'-81⁄2" (2045) 4'-9
3⁄4" (1467) 3'-6" (1067)
3500 (1588) SSP-CO 9'-5" (2870) 7'-91⁄2" (2375) 6'-8
1⁄2" (2045) 5'-5
3⁄4" (1670) 3'-6" (1067)
4000 (1814) CO 10'-5" (3175) 7'-91⁄2" (2375) 7'-8
1⁄2" (2350) 5'-5
3⁄4" (1670) 4'-0" (1219)
4000 (1814) 2SP 8'-5" (2565) 10'-1" (3073) 5'-81⁄2" (1740) 7'-6
1⁄2" (2299) 4'-0" (1219)
4500 (2041) 2SP 8'-5" (2565) 10'-7" (3226) 5'-81⁄2" (1740) 8'-0
1⁄2" (2451) 4'-0" (1219)
5000 (2268) 2SP 8'-5" (2565) 11'-23⁄4" (3422) 5'-8
1⁄2" (1740) 8'-8
1⁄4" (2648) 4'-6"* (1372)
5000 AIA (2268) 2SP 8'-5" (2565) 11'-63⁄4" (3524) 5'-8
1⁄2" (1740) 9'-0" (2743) 4'-6"* (1372)
4000 (1814) 2SP 8'-5" (2565) 9'-5" (2870) 5'-81⁄2" (1740) 7'-6" (2286) 4'-0" (1219)
4500 (2041) 2SP 8'-5" (2565) 9'-11" (3023) 5'-81⁄2" (1740) 8'-0" (2438) 4'-0" (1219)
5000 (2268) 2SP 8'-5" (2565) 10'-2" (3099) 5'-81⁄2" (1740) 8'-7
3⁄4" (2635) 4'-6"* (1372)
5000 AIA (2268) 2SP 8'-5" (2565) 10'-73⁄4" (3245) 5'-8
1⁄2" (1740) 9'-0" (2743) 4'-6"* (1372)
2000 5'-4" (1626) 13'-1" (3988) – – – –
2500 – 3500 5'-5" (1651) 13'-7" (4140) 5'-5" (1651) 13'-8" (4166) 6'-0" (1829) 13'-11" (4242)
4000 5'-8" (1728) 13'-7" (4140) 5'-10" (1778) 13'-8" (4166) 6'-5" (1956) 13'-11" (4242)
4500 6'-6" (1982) 13'-7" (4140) 6'-5" (1956) 13'-8" (4166) – –
5000 – 5000 AIA 7'-2" (2185) 13'-7" (4140) 7'-2" (2185) 13'-8" (4166) – –
KONE MonoSpace Planning Guide:Machine at Side Configuration – (Available in passenger and service shape with front and rear opening options)
MAX TRAVEL230 ft (70.1 m)
MAX LANDINGS36
SPEED200, 350, 500 fpm
(1.00, 1.78, 2.54 m/s)
CAR HEIGHT 8, 9 or 10 ft
(2438, 2743
or 3048 mm)
ENTRANCEHEIGHT 7, 8 or 9 ft
(2134, 2438
or 2743 mm)
F
G
Plan Views
Section View
9KONE Architectural Planning Guide
KO
NE E
coSp
ace
K
ON
E M
on
oSp
ace
KO
NE E
coSyste
m M
RK
ON
E A
lta
Adjacent orRemote Control Room
(option 2)
B
L
J
(10)
Remote Control Closet(option 1)
K
LJ
(10)
Integral Controller Space (standard)
(8)
(8) (9)
A
C
D
K
B
LJ
E
E
(10)
(3)
(1) (2)
H F G
G
I
(4)
(5)
TRAVEL
10 KONE Architectural Planning Guide
KO
NE E
coSp
ace
K
ON
E M
on
oSp
ace
KO
NE E
coSyst
em
MR
KO
NE A
lta
KONE EcoSystem MR E
DB
E
C
A
(2)
(6)
I
TRAVEL
J
G
GF
(8)
(4)
(5)
SERV
ICE
PASSEN
GER
Fro
nt
& R
evers
e O
pen
ing
Fro
nt
Op
en
ing
SERV
ICE
PASSEN
GER
EcoSystem MR A B C D E
2000 SSP 8'-4" 6'-31⁄4" 5'-81⁄2" 4'-31⁄4" 3'-0"(907) (2540) (1911) (1740) (1302) (914)
2500 SSP-CO 9'-4" 6'-3 1⁄4" 6'-81⁄2" 4'-33 ⁄4" 3'-6"(1134) (2845) (1911) (2045) (1314) (1067)
3000 SSP-CO 9'-4" 6'-91⁄4" 6'-81⁄2" 4'-93 ⁄4" 3'-6"(1361) (2845) (2064) (2045 ) (1467) (1067)
3500 SSP-CO 9'-4" 7'-51⁄4" 6'-81⁄2" 5'-53 ⁄4" 3'-6"(1588) (2845) (2267) (2045) (1670) (1067)
4000 CO 10'-4" 7'-51⁄4" 7'-8 1⁄2" 5'-53 ⁄4" 4'-0"(1814) (3150) (2267) (2350) (1670) (1219)
4000 2SP 8'-1" 10'-1" 5'-81⁄2" 7'-61⁄2" 4'-0"(1814) (2464) (3073) (1740) (2299) (1219)
4500 2SP 8'-1" 10'-7" 5'-81⁄2" 8'-01⁄2" 4'-0"(2041) (2464) (3226) (1740) (2451) (1219)
5000 2SP 8'-1" 11'-23 ⁄4" 5'-81⁄2" 8'-81 ⁄4" 4'-0"(2268) (2464) (3423) (1740) (2648) (1219)
5000 AIA 2SP 8'-8" 11'-63 ⁄4" 5'-81⁄2" 9'-0" 4'-6"(2268) (2642) (3524) (1740) (2743) (1372)
CAPACITY OPENING HOISTWAY HOISTWAY INTERIOR INTERIOR DOORLBS (kg) TYPE WIDTH (mm) DEPTH (mm) WIDTH (mm) DEPTH (mm) WIDTH (mm)
2000 SSP 7'-4" 6'-10" 5'-8 1⁄2" 4'-31⁄4" 3'-0"(907) (2235) (2083) (1740) (1302) (914)
2500 SSP-CO 8'-4" 6'-8" 6'-81⁄2" 4'-31⁄4" 3'-6"(1134) (2540) (2032) (2045) (1302) (1067)
3000 SSP-CO 8'-4" 7'-2" 6'-81⁄2" 4'-91⁄4" 3'-6"(1361) (2540) (2184) (2045) (1454) (1067)
3500 SSP-CO 8'-4" 7'-10" 6'-81⁄2" 5'-51⁄4" 3'-6"(1588) (2540) (2388) (2045) (1657) (1067)
4000 CO 9'-4" 7'-10" 7'-81⁄2" 5'-51⁄4" 4'-0"(1814) (2845) (2388) (2350) (1657) (1219)
4000 2SP 8'-1" 9'-2" 5'-81⁄2" 7'-6" 4'-0"(1814) (2464) (2794) (1740) (2286) (1219)
4500 2SP 8'-1" 9'-8" 5'-81⁄2" 8'-0" 4'-0"(2041) (2464) (2946) (1740) (2438) (1219)
5000 2SP 8'-1" 10'-2" 5'-81⁄2" 8'-73 ⁄4" 4'-0"(2268) (2464) (3099) (1740) (2635) (1219)
5000 AIA 2SP 8'-8" 10'-73 ⁄4" 5'-81⁄2" 9'-0" 4'-6"(2268) (2642) (3245) (1740) (2743) (1372)
Notes
(1) For speeds above 700 fpm (3.56 m/s) or travel
above 590' (180 m) contact your KONE Sales
Professional for design and planning assistance.
(2) For 700 fpm (3.56 m/s) front opening passenger
configurations add 2" (51 mm) to the hoistway
depth .
(3) Information is based upon chain compensation.
For rope compensation applications, please
consult your KONE Sales Professional.
(4) All dimensions are based on an 8'-0" (2438 mm)
cab with a 7'-0" (2134 mm) door. Alternate car
and door heights are available, but will affect
dimension .
(5) If occupied space exists below the hoistway,
consult your KONE Sales Professional.
(6) For seismic applications (zone 2 or greater) add 4"
(102 mm) for passenger elevators and 3" (76 mm)
for service elevators to hoistway width .
(7) Information is based upon structural machine room
floor slabs. For machine beam applications, please
consult your KONE Sales Professional.
(8) Machine room height of 8'-0" (2438 mm) is
measured from the machine room floor surface
to underside of the lowest obstruction above
the machine . Consult your KONE Sales
Professional for details.
(9) For service applications the machine room is
not centered on the hoistway and requires
an additional 7" (178 mm) of width. The
additional 7" (178 mm) should be added to
the counterweight side. Consult your KONE
Sales Professional for details.
Visit www.us.kone.com for the latest
job-specific details, CAD drawings,
specifications, electrical data,
reaction loads, cab designer tool
and building access requirements.
A
H
I
B
MAX TRAVEL 590 ft (180 m)
MAX LANDINGS 63
SPEED 200, 350, 500, 700 fpm (1.00, 1.78, 2.54, 3.56 m/s)
CAR HEIGHT 8, 9 or 10 ft (2438, 2743 or 3048 mm)
ENTRANCE HEIGHT 7, 8 or 9 ft (2134, 2438 or 2743 mm)
CLEAR OVERHEAD and PIT DEPTH
F
G
JI
CAPACITY PIT CLEAR PIT CLEAR PIT CLEAR PIT CLEAR PIT CLEARLBS (kg) DEPTH OVRHD DEPTH OVRHD DEPTH OVRHD DEPTH OVRHD DEPTH OVRHD
(mm) (mm) (mm) (mm) (mm) (mm) (mm) (mm) (mm) (mm)
2000 – – – – – – – – 10'-6" 21'-0"
(907) – – – – – – – – (3200 mm) (6401)
2500-3500 5-'3" 14'-1" 5'-6" 14'-7" 6'-0" 14'-11" 6'-10" 15'-8" 10'-6" 21'-0"
(1134-1588) (1600) (4292) (1676) (4445) (1829) (4547) (2083) (4775) (3200) (6401)
4000 5-'3" 14'-1" 5'-6" 14'-7" 6'-0" 14'-11" 6'-10" 15'-8" – –
(1814) (1600) (4292) (1676) (4445) (1829) (4547) (2083) (4775) – –
4500 5-'3" 14'-7" 5'-6" 15'-1" 6'-0" 15'-5" 6'-10" 16'-2" – –
(2041) (1600) (4445) (1676) (4597) (1829) (4953) (2083) (4928) – –
5000 5-'3" 14'-7" 5'-6" 15'-1" 6'-0" 15'-5" 6'-10" 16'-2" – –
(2268) (1600) (4445) (1676) (4597) (1829) (4953) (2083) (4928) – –
5000 AIA 5'-6" 14'-9" 5'-8" 15'-1" 7'-2" 16'-2" 7'-2" 16'-2" – –
(2268) (1676) (4496) (1727) (4597) (2184) (4928) (2184) (4928) – –
200 FPM 350 FPM 400 FPM 500 FPM 700 FPM (1,2,3)1.00 m/s 1.78 m/s 2.03 m/s 2.54 m/s 3.56 m/s (1,2,3)
H
For more information on Alta, contact KONE Major Projects Unit at
(630) 955-3195(630) 955-3192 (fax)
11KONE Architectural Planning Guide
KO
NE E
coSp
ace
K
ON
E M
on
oSp
ace
KO
NE E
coSyste
m M
RK
ON
E A
lta
KONE AltaKONE Alta began as a vision, drawing
upon our global resources as the
recognized innovators in the industry,
and raised elevator technology to
new heights.
Alta is the ultimate high-performance
elevator system dedicated to the
world’s tallest buildings, offering a
unique combination of intelligence,
speed, ride comfort, reliability, safety,
space and energy efficiency. The
KONE Alta blends advanced technology
with design flexibility, backed up by
our global project planning and
implementation capabilities.
Alta is performance, finely tuned to
enhance your building.
Hyatt Center
300 North LaSalle
12 KONE Architectural Planning Guide
Escalators + Autowalks
For the latest product information and interactive design tools, visit www.us.kone.com
n Quiet, smooth operationn Small installation dimensionsn Efficient and economicaln High levels of reliabilityn Design options to match the
image of your building
Application Retail, airports,
stadiums, hotels,
leisure venues
Type Escalator
Rise Maximum 49'-29⁄16"
Nominal
Step Width 24", 32", 40"
(600, 800,
1000 mm)
Balustrade Glass or solid
Speed 100 fpm (.50 m/s)
KONE ECO3000 escalators
raise global standards with
innovative technology, space-
savings, environmentally sound
design, leading-edge style
and safe, reliable performance
– all backed by the experience
and expertise of a world leader
in vertical transportation.
KONE ECO3000®
Application Heavy traffic
Type Autowalk
Length Per requirements
Nominal
Pallet Width 32", 40", 48", 56"
(800, 1000,
1200, 1400 mm)
Balustrade Glass or solid
Speed 100 or 130 fpm
(.50 or .66 m/s)
The KONE Autowalk achieves
the perfect balance between
form and function. An attractive
welcome area invites passengers
to take an uncommonly
smooth and quiet ride, while
offering options to meet your
architectural vision.
KONE Autowalk
Application Retail, airports,
stadiums, hotels,
leisure venues
Type Complete escalator
modernization
Nominal
Step Width 24", 32", 40"
(600, 800,
1000 mm)
Balustrade Glass or solid
Speed 100 fpm (.50 m/s)
The KONE EcoMod escalator
modernization solution offers
an innovative and systematic
approach to replacing the entire
workings of your escalators and
delivering brand new ECO3000
technology without expensive,
disruptive truss removal.
KONE EcoMod™
Application Heavy traffic,
public
transportation,
Metro
Type Escalator
Nominal
Step Width 40" (1000 mm)
Balustrade Glass or solid
Speed 100 fpm (.50 m/s)
The versatile TransitMaster 140
escalator is ideal for new
installations and is specifically
designed to meet the demands
and needs of the market sector
all the way up to the demanding
requirements of mass transit
airport and railway systems.
Our heavy-duty escalators
are designed to enable the
seamless flow of large numbers
of passengers.
Planning details are available in
our full Escalator & Autowalk
Planning Guide. See
www.us.kone.com/escalators or
contact your local KONE Sales
Representative for more details.
TransitMaster™ 140
Detail 2
13KONE Architectural Planning Guide
KO
NE E
CO
3000
KO
NE A
uto
walk
KO
NE E
coM
od
KONE ECO3000 escalators are available
in three step widths, glass or solid
balustrades and many other available
options and finishes. The robust
design, coupled with excellence
in manufacturing and service, keep
KONE at the top of the list of
preferred suppliers of escalators for
airports and lightly used railway or
metro stations, public access, office
or retail applications.
KONE ECO3000
Detail 1
Notes
(1) Details represent standardKONE escalator configurations.Please consult your SalesProfessional to review all possible deviations.
(2) Please visit www.us.kone.comfor the latest job-specificdetails, electrical data, reaction loads, cab designertool and building accessrequirements.
Inclination 30 degrees
Level Steps 2 or 3 Level Steps
Radii 3'-33⁄8" or 4'-11" (1.0 or 1.5 m) Upper Radius
Maximum 49'-29⁄16" (15m)Vertical Rise
Nominal 24", 32" and 40" Step Width (600, 800, 1000 mm)
Balustrade Glass, Solid Vertical or Solid Inclined
Balustrade Height 3'-33⁄8" (1000 mm)
Speed 100 fpm (0.5 m/s)
Electrification ANSI
Chain Type Inside Chain Roller
Handrail C or V-type
Environment Indoor, Semi-outdoor or Outdoor
KONE ECO3000 – Basic Data
NOMINAL STEP WIDTH (A) 24" (600 mm) 32" (800 mm) 40" (1000 mm)
Center to Center of handrail (B) 2'-101⁄8" (867 mm) 3'-57⁄8" (1064 mm) 4'-111⁄16" (1262 mm)
Finished width of escalator (D) 3'-111⁄16" (1195 mm) 4'-67⁄8" (1394 mm) 5'-211⁄16" (1592 mm)
Width of pit (C) 4'-11⁄16" (1246 mm) 4'-87⁄8" (1445 mm) 5'-45⁄8" (1641 mm)
Detail 1
MA
X.
RIS
E
E
F
G
L
2-LEVEL STEPS 2-LEVEL STEPS 3-LEVEL STEPS
24" (600) STEP 37'-613⁄16" (11.45 m) 24" (600) STEP 37'-613⁄16" (11.45 m) 24" (600) STEP 37'-613⁄16" (11.45 m)
32" (800) STEP 28'-23⁄5" (8.6 m) 32" (800) STEP 47'-6" (14.47 m) 32" (800) STEP 47'-6" (14.47 m)
40" (1000) STEP 23' (7.01 m) 40" (1000) STEP 49'-29⁄16" (15 m) 40" (1000) STEP 49'-29⁄16" (15 m)
NON-SEISMIC SEISMIC NON-SEISMIC SEISMIC NON-SEISMIC SEISMIC(mm) (mm) (mm) (mm) (mm) (mm)
13'-91⁄16" (4193) 13'-105⁄8" (4232) 13'-91⁄16" (4193) 13'-105⁄8" (4232) 15'-13⁄16" (4593) 15'-23⁄8" (4632)
8'-13⁄16" (2469) 8'-23⁄4" (2508) 8'-61⁄2" (2604) 8'-81⁄16" (2643) 9'-101⁄4" (3004) 9'-1113⁄16" (3043)
7'-23⁄8" (2194) 7'-315⁄16" (2234) 7'-23⁄8" (2194) 7'-315⁄16" 2234) 8'-61⁄8" (2594) 8'-711⁄16" (2634)
A+15'-39⁄16" (4663) A+15'-611⁄16" (4742) A+15'-813⁄16" (4796) A+16' (4877) A+18'-43⁄8" (5598) A+18'-71⁄2" (5677)
Detail 2
3'-33⁄8" (1.0 m) upper radius 4'-11" (1.5 m) upper radius 4'-11" (1.5 m) upper radius
14 KONE Architectural Planning Guide
KO
NE E
CO
3000
KO
NE A
uto
walk
KO
NE E
coM
od
KONE Autowalk Stanchion
KONE Autowalks have been installed
in all types of applications. Exposition
centers, stadiums, auditoriums and
airports are only a few of the many
applications where autowalks can move
high numbers of people smoothly
and efficiently. High-profile projects
include: The Denver International
Airport, Miami International Airport,
Atlanta International Airport and
Dallas-Fort Worth International
Airport, to name a few.
32" (800) 4'-111⁄8" (1052) 5'-11⁄8" (1553)
40" (1000) 5'-615⁄16" (1700) 5'-815⁄16" (1751)
48" (1200) 6'-23⁄4" (1899) 6'-43⁄4" (1950)
56" (1400) 6'-101⁄2" (2096) 7'-01⁄2" (2146)
KONE Autowalk – Stanchion StyleBasic DataNOMINAL PALLET WIDTH (A) (mm)
ROUGH OPENING (C) (mm)
FINISHED WIDTH(B) (mm)
Inclination 0 deg – 3 deg at ends
for no wellway applications
Nominal 32", 40", 48" and 56" (800, Pallet Width 1000, 1200 and 1400 mm)
Balustrade Glass or Solid Vertical Panels
Balustrade 2'-103⁄16" (868 mm)
Height
Speed 100 fpm (0.5 m/s) or 130 fpm (0.65 m/s)
Electrification ANSI
Chain Type Rollers outside chain links
Handrail V-type
Environment Indoor, Semi-outdoor or Outdoor
KONE Autowalk – Stanchion Basic Data
Notes
(1) Details represent standard KONE escalator configurations. Please consult your Sales Professional to review all possible deviations.
(2) Please visit www.us.kone.com for the latest job-specific details, electrical data, reactionloads, cab designer tool and building access requirements.
15KONE Architectural Planning Guide
KO
NE E
CO
3000
KO
NE A
uto
walk
KO
NE E
coM
od
KONE EcoModNew escalators the quick and easy way
KONE is the only company that offers
a complete escalator modernization
solution without the expense and
disruption of removing the existing
truss. During modernization we can
maintain continuous people flow.
KONE EcoMod delivers brand new
escalator technology without the
need to demolish floors, roofs and
building façades, and there’s always
an escalator available for passengers.
EcoMod is designed to be compatible
with both KONE escalators and
equipment from other manufacturers.
New technology = better escalatorsn Improved equipment dependability
and performance
n Enhanced safety and reliability
n Energy-efficient technology for
reduced operating costs
n Improved user experience with
smoother rides
n Increased building value
For additional information
please contact your KONE
Sales Representative.
Quick and Easy Installation
A KONE EcoMod complete escalator modernization begins with the
removal of all existing mechanical and electrical components. The existing
truss is then modified to accept KONE EcoMod modules, allowing
quick installation of the latest technology without major disruption.
upper module1
incline modules2
lower module3
EcoMod Installation Advantagesn Quicker, cleaner and less costly than
a new installation
n Modifying the existing truss means
no major structural modifications
n Reuse of existing cladding and deck-
ing for significant cost-savings
n One or more escalators always
available to passengers
n Increased building value and
simplified budgeting process
Traditional Installation Disadvantages
n Lengthy process with extensive
construction
n Substantial general contractor costs
for work by others
n Additional time for removal and prep
of structural and related elements
n Complete escalator shutdown
during construction
n Major disruption to people flow
It’s wise to modernize
U.S. Operations Center
One KONE Court
Moline, Illinois 61265
1-800-956-KONE (5663)
Canadian Operations Center
80 Horner Avenue
Toronto, Ontario M8Z 4X8
1-416-252-6151
KONE Mexico, S.A. de C.V.
Clavel 227
Colonia Atlampa
Mexico City, D.F. 06450
+52.55.1946.0100
For the latest product information
and interactive design tools, visit
www.us.kone.com
Alabama
Birmingham 205-944-1032
Mobile 251-661-7522
Arizona
Phoenix 602-269-7877
Tucson 520-624-3125
Arkansas
Little Rock 501-758-1889
California
Los Angeles 562-921-1555
Sacramento 916-372-1458
San Diego 858-679-2400
San Francisco 510-351-5141
Santa Barbara 805-349-1013
Colorado
Denver 303-792-3423
Connecticut
Hartford 860-257-9277
Delaware 856-251-1555
District of Columbia
Washington, DC 301-459-8660
Florida
Jacksonville 904-292-0225
Miami 954-437-4300
Naples 239-598-9310
Orlando 407-812-8033
Tampa 813-635-0330
Georgia
Atlanta 770-427-3373
Hawaii
Honolulu 808-836-2231
Idaho 801-977-1144
Illinois
Chicago 630-629-3100
Peoria 309-697-9011
Quad Cities 309-797-3232
Rockford 815-874-1502
Indiana
Fort Wayne 260-484-9586
Indianapolis 317-788-0061
Iowa
Des Moines 515-243-0109
Quad Cities 309-797-3232
Kansas
Wichita 316-942-1201
Kentucky
Louisville 502-491-0565
Louisiana
Baton Rouge 225-291-5270
New Orleans 504-736-0776
Maine 781-828-6355
Maryland
Baltimore 410-766-2100
Massachusetts
Boston 781-828-6355
Michigan
Detroit 734-513-6944
Grand Rapids 616-534-3300
Minnesota
Minneapolis 651-452-8062
Mississippi
Jackson 601-939-7597
Missouri
Kansas City 816-531-2140
St. Louis 314-521-8800
Springfield 417-862-1174
Montana
Helena 406-449-1399
Nebraska
Omaha 402-592-7381
Nevada
Las Vegas 702-269-0919
New Hampshire 781-828-6355
New Jersey
High Bridge 908-638-6881
New Mexico
Albuquerque 505-888-0626
New York
Albany 518-464-0002
New York City 718-361-7200
North Carolina
Charlotte 704-597-0430
North Dakota 651-452-8062
Ohio
Cincinnati 513-755-6195
Cleveland 440-546-1100
Columbus 614-866-1751
Oklahoma
Oklahoma City 405-682-5651
Tulsa 918-258-0582
Oregon
Portland 503-652-1011
Pennsylvania
Harrisburg 717-653-7177
Philadelphia 856-488-8830
Pittsburgh 412-279-1561
Rhode Island 781-828-6355
South Carolina 704-597-0430
South Dakota
Sioux Falls 605-336-1578
Tennessee
Knoxville 865-938-3444
Memphis 901-758-8320
Nashville 615-360-7013
Texas
Austin 512-443-0967
Dallas 469-549-0581
Houston 281-442-6619
San Antonio 210-491-0485
Utah
Salt Lake City 801-977-1144
Vermont 781-828-6355
Virginia
Richmond 804-328-1032
Washington
Seattle 425-861-9696
West Virginia
Charleston 614-866-1751
Morgantown 412-279-1561
Wisconsin
Milwaukee 262-373-0460
Wyoming 303-792-3423
U.S. Offices
Canada Offices
KONE Inc. reserves the right to alter
design and specifications without
prior notice.
KONE is a registered trademark of
KONE Inc. Dedicated to People Flow
and XXXXXXXXXX are trademarks of
KONE Inc.
“USGBC” and related logo is a
trademark owned by the U.S. Green
Building Council and is used by
permission.
Alberta
Calgary 403-275-5650
Edmonton 780-452-9227
British Columbia
Vancouver 604-777-5663
Victoria 250-384-0613
Kelowna 250-491-1838
Manitoba
Winnipeg 204-895-2942
Nova Scotia
Halifax 902-450-1102
Ontario
Hamilton 905-648-3188
Kingston 613-531-6262
Ottawa 613-225-8222
Toronto 905-948-2230
Quebec
Montreal 514-284-2025
Quebec City 418-877-1494
Sherbrooke 819-821-2182
This document is printed using soy-based inks.©2010 KONE Inc.
SFXXXX Rev XXXX
Printed in U.S.A
KONE Inc. reserves the right to alterdesign and specifications withoutprior notice.
KONE, ECO3000, EcoDisc andMonoSpace are registered trademarksof KONE Inc. Alta, Dedicated toPeople Flow, Eco-efficient, EcoMod,EcoSpace, EcoSpace EB, EcoSystemMR and Silent Car are trademarks of KONE Inc.
“USGBC” and related logo is atrademark owned by the U.S. Green Building Council and is used by permission.
©2010 KONE Inc.SF2861 Rev 0910Printed in U.S.A.