leaders in life. safety. technology. onyx ® series fire alarm control panels
Post on 28-Dec-2015
222 Views
Preview:
TRANSCRIPT
Leaders in Life. Safety. Technology.Leaders in Life. Safety. Technology.Leaders in Life. Safety. Technology.Leaders in Life. Safety. Technology.
ONYXONYX®® Series SeriesFire Alarm Control PanelsFire Alarm Control Panels
2Leaders in Life. Safety. Technology.Leaders in Life. Safety. Technology.
ONYX Series
NFS-640 and NFS-3030 A family of fire alarm control systems
Common options and accessories Common look and feel
Backward compatible Upgrades are easy!
3Leaders in Life. Safety. Technology.Leaders in Life. Safety. Technology.
ONYX Series VeriFire Tools
PC-based offline programming tool Create and backup programs in the office or
field Integrates with Excel
Ability to create programs quickly
4Leaders in Life. Safety. Technology.Leaders in Life. Safety. Technology.
NFS-640
One SLC, expandable to two FlashScan™ - 159 detectors/159 devices CLIP Protocol – 99 detectors/99 devices
Isolated Loops for greater noise immunity Ground fault detection for each loop
Integrated 6 amp power supply Four fully programmable NACs with sync
5Leaders in Life. Safety. Technology.Leaders in Life. Safety. Technology.
NFS-640
Three display options 80 character 640 character No display
Built-in network protocol 103 nodes supported Wire or fiber combinations
6Leaders in Life. Safety. Technology.Leaders in Life. Safety. Technology.
The ONYX NFS-3030
NOTIFIER flagship panel Designed for medium to large systems. Up to ten SLC loop cards
FlashScan™ - 159 detectors/159 devices CLIP Protocol – 99 detectors/99 devices
7Leaders in Life. Safety. Technology.Leaders in Life. Safety. Technology.
Adapts…To Any Situation
Built-in expandability Modular design meets
any application The NFS-3030 will grow
to meet your expanding business needs
8Leaders in Life. Safety. Technology.Leaders in Life. Safety. Technology.
Key Features
Response times exceed worldwide code requirements ( < 3 sec )
Network compatible – 103 nodes
9Leaders in Life. Safety. Technology.Leaders in Life. Safety. Technology.
Key Features
ONYX Intelligent Sensing algorithms Enhanced Walk Test options Supports the widest range of specialty
sensors in the industry Auto-Program
10Leaders in Life. Safety. Technology.Leaders in Life. Safety. Technology.
Key Features
Isolated SLC loops Supports up to 12 panel circuit modules Multiple suppression options Expanded software zones 4000 event non-volatile history file
11Leaders in Life. Safety. Technology.Leaders in Life. Safety. Technology.
Advanced Technology
Flash memory...no need to change EPROM's Customers can receive upgrades via modem
or web Reduces cost of labor and parts
Database signature protection Prevents accidental data loss
12Leaders in Life. Safety. Technology.Leaders in Life. Safety. Technology.
Display Options
CPU-3030 display QWERTY keypad and
640-character LCD CPU-3030ND (no
display Service LEDs for
annunciation Switches for control Network only
13Leaders in Life. Safety. Technology.Leaders in Life. Safety. Technology.
160-Character Event Format160-Character Event Format
ACKNOWLEDGED FIRE ALARMMAIN ELEVATOR LOBBY EAST WING FIFTH FLOOR Z005 SMOKE(PHOTO) 9:55:24A FRI SEP 06, 2002 L01D126 9:56:12A FRI SEP 08, 2000
• Up to 40 characters describe the event without abbreviations
• Up to 52 custom characters plus type ID to aid in pinpointing the location of events
• Variable time format with one second accuracy
14Leaders in Life. Safety. Technology.Leaders in Life. Safety. Technology.
Scroll Display Switches
Provide the ability to view clearly events by type. Fire Alarm Security Supervisory Trouble Other
15Leaders in Life. Safety. Technology.Leaders in Life. Safety. Technology.
History Features
4000 event non-volatile history file Protects against data loss
Separate 1000 fire alarm event history Alarms are not overwritten by other events
Advanced history filters allow sorting by event, time, date or address
16Leaders in Life. Safety. Technology.Leaders in Life. Safety. Technology.
Reports
Detector maintenance report. Cleanliness and existing condition of detection
devices Installed point report.
Provides quick lookup information Allows printing functions without need for
attached PC
17Leaders in Life. Safety. Technology.Leaders in Life. Safety. Technology.
FlashScan® (US Pat 5,539,389)
A high-speed digital polling protocol Maintains sensor data for analysis and
trending Support new panel features with no need to
replace sensors
18Leaders in Life. Safety. Technology.Leaders in Life. Safety. Technology.
FlashScan
Enhanced Walk Test options Basic/One-man test reduces labor Advanced test bypasses detector initialization
saving time between tests Multicolor LEDs
LEDs indicate device address and testing status
19Leaders in Life. Safety. Technology.Leaders in Life. Safety. Technology.
Programming Options
Fully keypad programmable Changes can be made
without a PC Auto-Program learns
devices and assigns default parameters New installations are
protected in minutes
20Leaders in Life. Safety. Technology.Leaders in Life. Safety. Technology.
Programming Options
VeriFire Tools Create programs in the
office Test and compare
programs Communicate with all
network panels from any network location
21Leaders in Life. Safety. Technology.Leaders in Life. Safety. Technology.
Software Zones
1000 General zones Simplified linking of inputs to outputs
1000 Logic zones Allows conditional I/O linking such as AND,
OR, NOT, ANYx 100 Trouble zones
Alter programming parameters based on specific fault conditions
22Leaders in Life. Safety. Technology.Leaders in Life. Safety. Technology.
Suppression Options
Multiple Releasing zones Protect against ten independent hazards
Three sophisticated Cross-zone options Allows flexibility for any application
Four Abort options Designed to comply with all jurisdictions
23Leaders in Life. Safety. Technology.Leaders in Life. Safety. Technology.
Optional Annunciators
24Leaders in Life. Safety. Technology.Leaders in Life. Safety. Technology.
Expanded ACS Protocol
96 pts / address Reduces cost per
annunciator point Enable / disable
Provides faster access to daily or repetitive tasks
Selectable LED colors Meets any local code
requirements
25Leaders in Life. Safety. Technology.Leaders in Life. Safety. Technology.
Supports Smoke Control
FSCS mode NFPA-92A, 90B
HVAC mode NFPA 90A
26Leaders in Life. Safety. Technology.Leaders in Life. Safety. Technology.
Smoke Control Station
Up to four modules/group
Three position toggle switches On / Off / Auto
Control On
Control Off
Monitor On
Monitor Off
SCS-8
Leaders in Life. Safety. Technology.Leaders in Life. Safety. Technology.Leaders in Life. Safety. Technology.Leaders in Life. Safety. Technology.
ONYX Digital Voice Command ONYX Digital Voice Command
28Leaders in Life. Safety. Technology.Leaders in Life. Safety. Technology.
System Definition
ONYX Digital Voice Command [DVC] is NOTIFIER's new digital audio system with: Audio evacuation Paging Firefighter's telephone
Eight channels of quality audio for: Live emergency paging Simultaneous broadcasting of multiple stored
messages
29Leaders in Life. Safety. Technology.Leaders in Life. Safety. Technology.
System Definition
ONYX DVC broadcasts simultaneous, unique messages throughout your entire facility or select designated areas
ONYX DVC provides critical information or instruction in an emergency
ONYX DVC ensures the right people have the right information at the right time during the following: Smoke Fire Intrusion Chemical spill Weather event
30Leaders in Life. Safety. Technology.Leaders in Life. Safety. Technology.
True Digital for Unparalleled Clarity
From message storage to amplifier, everything is digital to eliminate distortion
Up to 32 Digital Audio Amplifiers can be connected to a DVC center
Each DAA is configurable as a primary or backup amplifier
DAA is a powerful 50 Watts in either 25 Volt or 70 Volt versions with four outputs per amplifier.
31Leaders in Life. Safety. Technology.Leaders in Life. Safety. Technology.
Large Number of Audio Zones
Larger applications can be accommodated with additional DVC centers
Each networked DVC adds support for another 32 DAA series amplifiers
Applications requiring hundreds of zones can be created by networking additional DVC centers over NOTI•FIRE•NET™
32Leaders in Life. Safety. Technology.Leaders in Life. Safety. Technology.
Network for Survivability and Scalability
Multiple DVC centers can be networked together with seamless integration into NOTI•FIRE•NET
NOTI•FIRE•NET with DVC provides: Added survivability and scalability Multiple command center support System expansion
33Leaders in Life. Safety. Technology.Leaders in Life. Safety. Technology.
Paging Over the Fire Alarm Network
Every DVC has an interface with NOTI•FIRE•NET
One channel audio over NOTI•FIRE•NET allows for network-wide live paging
Allows one DVC center to page over the whole system when multiple DVC centers are networked.
34Leaders in Life. Safety. Technology.Leaders in Life. Safety. Technology.
Multiple Paging Options
Preprogrammed multiple paging groups are standard with DVC New Group Paging Options
Page Active EVAC areas Page Active ALERT areas Page Inactive areas All Call
Option to page Inactive Areas to simply notify occupants of a potential emergency.
Each group of occupants receives customized information
35Leaders in Life. Safety. Technology.Leaders in Life. Safety. Technology.
DVC Keypad for Simple Group Paging
36Leaders in Life. Safety. Technology.Leaders in Life. Safety. Technology.
Firefighter’s Telephone
Up to five channels of simultaneous Firefighter's Telephone operation
Crucial scene assessment information can be gathered more quickly for: Improved response efforts Increased safety of both building occupants and fire
service personnel
37Leaders in Life. Safety. Technology.Leaders in Life. Safety. Technology.
Large Memory Capacity
Memory capacity of up to 1000 audio sequences storage
16 minutes standard of stored audio messages expandable to 32 minutes
Store customized audio sequences for any potential emergency/evacuation messages.
38Leaders in Life. Safety. Technology.Leaders in Life. Safety. Technology.
Customized Audio Messages
Comes with a standard library of messages Message library speeds installation and simplifies
maintenance Record, edit, and distribute your own custom
messages or tones as standard .WAV format audio files
No more locked-down libraries and no need to change memory chips
39Leaders in Life. Safety. Technology.Leaders in Life. Safety. Technology.
Microphone Options
Local paging microphone option and Remote Microphone (RM-1) option.
Flexibility to page on site or from remote location to further enhance communications and life safety.
40Leaders in Life. Safety. Technology.Leaders in Life. Safety. Technology.
Backup Alarm
Alarm Bus backup activation in the event of communication loss between (DAA) and DVC center.
Two minute backup message storage
Alarm Bus initiates backup Emergency Message
Leaders in Life. Safety. Technology.Leaders in Life. Safety. Technology.Leaders in Life. Safety. Technology.Leaders in Life. Safety. Technology.
ONYX® Intelligent Sensing
42Leaders in Life. Safety. Technology.Leaders in Life. Safety. Technology.
ONYX® Intelligent Sensing
ONYX Intelligent Sensing Solves the most challenging and unique detection problems Offers the best protection from incipient fires by integrating:
Sophisticated sensor technology Powerful fire alarm control panel processing
ONYX Intelligent Sensing benefits: Minimized nuisance alarms Rapid, intelligent response Substantially reduced the cost of downtime due to false alarms or
fire related damage High-sensitivity without compromising stability or reliability
43Leaders in Life. Safety. Technology.Leaders in Life. Safety. Technology.
ONYX Intelligent Sensing Defined
Technologies Detector Sensitivity Adjust Maintenance Warnings Self-optimizing Pre-alarm Cooperative Detection Supervisory Smoke ID
Sensors VIEW Acclimate Plus HARSH
44Leaders in Life. Safety. Technology.Leaders in Life. Safety. Technology.
ONYX Intelligent Sensing
Programmed into every NOTIFIER ONYX Series Panel
Unique panel intelligence exclusive to NOTIFIER For enhanced protection, use specialty
sensors like VIEW Acclimate HARSH
45Leaders in Life. Safety. Technology.Leaders in Life. Safety. Technology.
Detector Sensitivity Adjust
Ability to program each and every detector’s settings, choosing from nine sensitivity levels
Nine sensitivity settings Provides options for controlling sensitivity levels to meet various
environmental conditions. Can be programmed manually or can alternate automatically
between daytime and night-time settings Nine distinct pre-alarm levels, based on pre-determined levels
of alarm
46Leaders in Life. Safety. Technology.Leaders in Life. Safety. Technology.
Sensitivity Levels
0.0%
0.5%
1.0%
1.5%
2.0%
2.5%
3.0%
3.5%
1 - (Hospital)2 - (Schools)
4 - (Office)
6 - (Mercantile)7 - (Industrial)
5 - (Residential)
8 - (Laundry)
3 - (Theater)CLEAN
DIRTY
Alarm Too Quickly
Alarm Too Slowly
9 - (Process Plant)
“Clean” vs. “Dirty” Environments
47Leaders in Life. Safety. Technology.Leaders in Life. Safety. Technology.
Self-Optimizing Pre-Alarm
A unique mode where the detector ‘learns’ its normal environment by measuring peak analog readings over a period of time
ONYX panel intelligence sets the Pre-Alarm levels just above these normal peaks.
Extremely sensitive pre-alarm capability with protection against nuisance alarms
Reduce false pre-alarms due to spikes
48Leaders in Life. Safety. Technology.Leaders in Life. Safety. Technology.
Three Maintenance Alerts
Determines when dust accumulation reaches an unacceptable level that can compromise detector performance
Control panel indicates one of three maintenance warning levels: Low Threshold Maintenance Required Maintenance Urgent
49Leaders in Life. Safety. Technology.Leaders in Life. Safety. Technology.
Three Maintenance Alerts
0
0.005
0.01
0.015
0.02
0.025
0.03
0.035
0.04
0.045
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27
Adjustment Periods
Ch
am
be
r V
alu
eUpper Chamber Threshold
Lower Chamber Threshold
Maintenance Alert
Low Chamber Value
Maintenance Urgent
Precise report on detector condition
50Leaders in Life. Safety. Technology.Leaders in Life. Safety. Technology.
Cooperative Sensing
Exclusively from NOTIFIER Combination of up to three sensors in reaching the
alarm decision Fire alarm control panel looks at the values from
adjacent devices rather than input from only one device
51Leaders in Life. Safety. Technology.Leaders in Life. Safety. Technology.
Cooperative Sensing
There are three generally accepted fire signatures; heat, smoke and light
Only NOTIFIER looks at a fourth signature: uniform smoke spread
Adds “distance” to the equation Smoke acts like a gas and will evenly disperse Increased response to uniformly distributed smoke Sampling over a wider area is more stable Reject isolated sources of false signals
52Leaders in Life. Safety. Technology.Leaders in Life. Safety. Technology.
Supervisory Smoke ID: Commercial Applications
Shift to Preventative Approach Where the probability of unwarranted alarms is high
Where smoke sensitivity is set to an extremely low level for use as a maintenance alert.
Allows smoke sensors to quickly sense overheating equipment prior to serious damage occurring.
Can be annunciated at an indicator panel in just the maintenance department
Will not sound general alarm
53Leaders in Life. Safety. Technology.Leaders in Life. Safety. Technology.
VIEW Very Intelligent Early Warning
VIEW laser system has an advanced laser light source and patented optical design.
Addressable, spot detector Replaces complex and expensive
aspirating systems in critical environments. Sensitivity that is 10 to 50 times higher
than present photoelectric technology. Adjustable sensitivity of pre-alarm and
alarm levels from 1.0%/ft. to .03%/ft.. VIEW offers:
very early warning individual point annunciation total supervision simplified maintenance.
54Leaders in Life. Safety. Technology.Leaders in Life. Safety. Technology.
VIEW Very Intelligent Early Warning
VIEW is ideal for critical applications where even a trace of undetected smoke is unacceptable: Network server rooms Telephone facilities Cleanrooms Mission critical areas Museums and archives Records Storage Equipment Rooms Archives
55Leaders in Life. Safety. Technology.Leaders in Life. Safety. Technology.
HARSH Hostile Area Smoke Head
Replaces heat detectors in hostile environments (e.g. dirty & non-direct water spray)
A small fan draws air and smoke into a photoelectric sensing chamber
Filter removes unwanted particulates and water mist without removing smoke.
Helps protect the detection chamber and electronics in damp and moisture-rich environments.
Easy-to-replace filter
56Leaders in Life. Safety. Technology.Leaders in Life. Safety. Technology.
HARSH Hostile Area Smoke Head
No longer compromise on detection in critical areas that are dirty or wet. Paper, lumber and textile mills Food processing plants Packaging areas (corrugated dust) Laundry facilities Zoos, stables, barns
57Leaders in Life. Safety. Technology.Leaders in Life. Safety. Technology.
Acclimate Plus
Acclimate Plus constantly monitors ambient conditions Adjusts detection parameters and alarm thresholds
automatically Provides maximum detection and reduced nuisance alarms Combines thermal and photoelectric technologies to
maximize detection across a broad range of fire types. Photo-Thermal design
Chamber sensitivity increases with heat. Heat only option. Freeze warning.
Ideal Acclimate Plus Applications: Office areas Schools Healthcare facilities, Hospitals Hospitality – Hotels/Motels Restaurants
Leaders in Life. Safety. Technology.Leaders in Life. Safety. Technology.Leaders in Life. Safety. Technology.Leaders in Life. Safety. Technology.
Thank you
top related