Specifications LM42 / LM42-SS
Please consult the manufacturer’s installation manual for all details and requirements before making a final
design layout decision.
Longmire Linear Wood-Burning Fireplace
1-1/2" [38]
15-1/2" [394]
1-1/2" [38]
31" [787]
65" [1651]
59-3/4" [1518]
18" [457]
12" [305]
16" [406]
38-1/8" [968]
42" [1067]62" [1575]
10" [254]
12-1/2" [318] 18-3/4"
[476]
8" [203]
53-1/4" [1353]
56-5/8" [1438]
24" [610]
12-1/2" [318]
10" [254]
MODEL FRONT WIDTH BACK WIDTH HEIGHT DEPTH VIEWING AREA
LM42LM42-SS
Actual Framing Actual Framing Actual Framing Actual Framing38-1/8" x 16"[968 x 406]65"
[1651]65-1/2"[1664]
65"[1651]
65-1/2"[1664]
59-3/4"[1518]
60-1/4"[1530]
24"[610]
24"[610]
Front View Top View
1-1/2" [38]
15-1/2" [394]
1-1/2" [38]
31" [787]
65" [1651]
59-3/4" [1518]
18" [457]
12" [305]
16" [406]
38-1/8" [968]
42" [1067]62" [1575]
10" [254]
12-1/2" [318] 18-3/4"
[476]
8" [203]
53-1/4" [1353]
56-5/8" [1438]
24" [610]
12-1/2" [318]
10" [254]
Right Side ViewLeft Side View
Specifications
HEARTH PAD EXTENSION
LM42 / LM42-SS
Heatilator • LM42 • Installers Manual • 4087-901 • Rev A • 04/14/1614
60-1/4"[1530]
65-1/2"[1664]
14-1/2"[368]
24"[610]APPLIANCE MAY BE INSTALLED
OFF OF FLOOR***
16"[406]
36"
0"
E=MEASUREMENT FROM TOP OF FIREPLACE OPENING TO CEILING
K=MEASUREMENT FROM BOTTOM OF FIREPLACE TO CEILING
0"
0"
MINIMUM FRAMING DIMENSIONS*
LM42A B C* D E F G H I
to
Depth
Behind
Appliance
Appliance
14-1/2" 60-1/4" 24" 0 16" 0" 0"
610 1664 914 0 406 0 0
* = Adjust framing dimensions for interior sheathing (such as sheetrock)
Construct platform in accordance with local building codes.
Figure 3.3 Clearances to Combustibles
" " "
FRAMING DIMENSIONSAPPLIANCE LOCATION – INSIDE
* 8" (203 mm) extra space included for outside air connection. If outside air duct has no bend, this dimension may be reduced as long as minimum clearances are met.
Across a corner
In an exterior chase
Along a wallAs a room divider
*
* *
80-3/4" [2051]30-3/8" [772]
30-3/8" [772]
58-1/2" [1486]
117" [2972]65"
[1651]
20" [508]
65" [1651]*73" [1854]
24" [610]
65" [1651]*73" [1854]
24" [610]
*73" [1854]
65" [1651]
24" [610]
48" [1219]
20" [508]
12" [305]
Note: If this surface is inside the building’s warm air envelope... ...then this surface
must be an exterior wall system.
20" [508]
* 8" (203 mm) extra space included for outside air connection. If outside air duct has no bend, this dimension may be reduced as long as minimum clearances are met.
*
*
80-3/4" [2051]30-3/8" [772]
30-3/8" [772]
58-1/2" [1486]
117" [2972]
65" [1651]
65" [1651]
*73" [1854]
24" [610]
*73"
[185
4]
65" [
1651
]
3 ft (914 mm)minimum
from fireplace openingto ceiling
Combustible Wall
2 x 4 header
Standoffs
Measured from top of fireplace opening
1 1/2 in./38 mmmaximum
Non-combustibleDecorative Facing
44 in.(1118 mm)minimum
Base of fireplace
Grid represents 1 in. squares
Mantel
12 in./305 mm
14 in./356 mmminimum
8 in./203mmminimum
APPLIANCE LOCATION – OUTSIDE
Hearth Extension Dimensions
Model # A B C
LM42in. 16 8
mm 1321 406
52"[1321] 8"
[203]
8"[203]
16"[406]
MANTEL AND WALL PROJECTIONS
WS/HTL/LONGMIRE/LM42_0416
PRODUCT LISTING CODES
US UL 127
CAN ULC-S610
Product information provided is not complete and is subject to change without notice. Product installation must adhere strictly to instructions accompanying product to avoid risk of fire and potential injury.
Additional information can be found online at www.heatilator.com