www.srtorque.com
Accuracy. Reliability. Durability,
Knurl-Grip
For Sturtevant Richmont Micrometer Adjustable Wrenches (Up To 250 Ft. Lb.)
Metal Handle Conversion Kit Instructions
Required ToolsWork Gloves
7/64”, 3/32”, 5/32”, and 5/16” hex key
Internal Straight Tip Ring Pliers (3/8”–1” or 10–25 mm)
Torque Wrench for 15 Ft. Lb. 5/16 hex bit socket
Hex head screwdriver
Locktite®
Process OverviewThe old griplock must be removed prior to removing the rubber grip and installing the new handle.
Knurl-Grip
www.srtorque.com
STEP ONETurn handle to minimum torque
position and lock the handle
STEP FIVESlide the new handle on to the wrench. Be sure to align the handle with the “0”
sightly to the left of the scale center line. Using the torque wrench set to 15 Ft. Lb. and the 5/16 hex bit socket, torque lock
plug to 15 Ft. Lb. Check calibration and if necessary recalibrate wrench. Please note
that the new load point for both usage and calibration is here.
For Sturtevant Richmont Micrometer Adjustable Wrenches (Up To 250 Ft. Lb.)
Load Point
Metal Handle Conversion Kit Instructions
Calibration ProcessUse a mechanical loader with a tester possessing an accuracy of at least +/-1%. A more accurate tester is always preferable.
Procedure1. Determine current performance to standard.
• Test wrench on torque analyzer/tester.
– Cycle wrench at 100% of capacity a minimum of three times.
– Set wrench to 20% of capacity, cycle three (3) times and record readings.
– Set wrench to 60% of capacity, cycle three (3) times and record readings.
– Set wrench to 100% of capacity, cycle three (3) times and record readings.
• Compare readings to tolerance for each torque level.
– If wrench is within tolerance, it may be returned to service.
– If wrench is out-of-tolerance, go to next step.
2. Calibrate wrench.
a. Remove tang access screw.
b. Remove griplock control knob and hex stem lock.
c. Rotate aluminum grip to 100% of capacity (highest graduation + 0 on increment).
d. Place wrench on torque analyzer/ tester, click several times, note values obtained.
e. Adjust wrench.
– If readings are above tolerance, turn tang adjustment screw slightly CW, then repeat step 2d.
– On the models highlighted on the last page there is a second set screw that is used as a jam nut. That (jam nut) set screw needs to be removed in order to make the calibration adjustment.
– If readings are below tolerance, turn tang adjustment screw slightly CCW, then repeat step 2d.*
– If readings are in tolerance, go to next step.
f. Rotate grip and adjust torque to 20% of capacity (lowest graduation + 0 on increment).
g. Place wrench on torque analyzer/ tester, click several times, note values obtained.
– If out-of-tolerance, go to next step.
– If in tolerance, check at 60% and 100% of capacity.
h. Rotate grip CW or CCW enough clicks to bring into tolerance at 20% of scale.
i. Lock load screw by rotating internal 5/32” internal hex screw in the CCW direction.
j. Use 5/16” hex key to remove lock plug by rotating in the CCW direction.
k. Rotate grip until it aligns with lowest graduation + 0 increment (20% of capacity).
l. Replace lock plug using torque wrench, torque lock plug to 15 Ft. Lb.
m. Return to step 2c.
n. Replace hex stem, lock control knob and lock control knob set screws. Tighten to 12.5 In. Lb.
o. If necessary, tighten setscrew in lock control knob until it lightly touches bottom, then back off 1/4 to 1/3 turn.
p. Replace tang access screw and grip.
*This adjustment should only be made at 100% capacity and it effects the calibration on a percentage basis meaning a change of 4% at the high end of the scale will effect the lower end of the scale by 4%. Example on a 200 Nm wrench a change of 4% = 8 Nm however at the bottom of the scale 40 Nm it would equal 1.6Nm or 4%.
S T E P - B Y- S T E P C O N V E R S I O N K I T I N S T R U C T I O N S
Accuracy. Reliability. Durability,
STEP FOURUsing 5/16 hex bit socket to remove
lock plug. Pull the handle straight back and remove from wrench.
STEP SIXSelect the correct hex stem lock from the conversion chart* for the model you are
converting. Hold wrench in a vertical position as shown. Insert the hex stem lock into the hex opening in the lock control knob. Gently rotate knob with
inserted hex key to complete engagement with locking screw inside of the load screw
assembly. NOTE: It is important that you DO NOT unlock the handle during
this process.
STEP THREEUsing an internal straight tips retainer
ring pliers, (3/8”–1” or 10–25 mm) squeeze and remove the snap ring, griplock
and hex stem lock.
STEP EIGHTApply “Locktite® 222” threadlocker
to the 5/16”–18 x 5/16” set screw thread. Tighten set screw into the lock knob using 5/32 hex key so it contacts, or
stops with the top face of the hex key, then rotate it back 1/4–1/3 of one turn.
Let the Locktite® dry for 12 hours.
STEP TWOLoosen the set screw using the 3/32 hex key in the back of the griplock
eight turns. To release tension gently tap griplock.
STEP SEVENTorque griplock set screws using 7/64 hex
key to 12.5 In. Lb. or until snug. To test lock after full assembly: Place in vertical
position with handle facing upwards. If the set screw is sticking out of the lock knob,
or the hex is too short, replace the hex stem lock with the other supplied hex
stem lock in the grip kit.
Griplock
Lock Control Knob
Hex Stem Lock
Set Screw
Lock Plug
Item Description
Rubber Grip Wrench Number
Knurl-Grip Kit Used
Knurl-Grip Wrench Number Hex Stem Used*
3 SD 200I 810159 869071 869159 869059
2 SD 50I 810160 869070 869160 869059
2 SD 150I 810161 869065 869161 869058
3 SD 750I 810163 869067 869163 869058
3 SD 75 810165 869069 869165 869058
4 SD 150 810167 869071 869167 869058
CCM 250I 810185 869066 869185 869058
9STCM 20 Nm 810300 869073 869300 869058
9STCM 100 Nm 810301 869069 869301 869058
14STCM 200 Nm 810303 869065 869303 869058
3 SDR 1200I 810747 869068 869747 869058
3 SDR 600I 810748 869067 869748 869058
2 SDR 50I 810749 869070 869749 869058
2 SDR 150I 810750 869071 869750 869058
3 SDR 150I 810751 869071 869751 869059
3 SDR 750I 810752 869067 869752 869058
3 SDR 100 810754 869065 869754 869058
4 SDR 1800I 810755 869068 869755 869058
3 SDR 75 810756 869069 869756 869058
4 SDR 150 810757 869065 869757 869058
4 SDR 250 810758 869066 869758 869058
3 SDR 200I 810761 869071 869761 869059
CCM 1800I 810762 869068 869762 869058
CCM 600I 810763 869067 869763 869059
CCM 1200I 810764 869068 869764 869058
CCM 150I 810765 869071 869765 869058
CCM 750I 810766 869067 869766 869058
CCM 50I 810769 869070 869769 869058
CCM 75I 810770 869069 869770 869058
CCM 150 810771 869065 869771 869058
CCM 200I 810773 869071 869773 869059
2 SDR 6 Nm 810774 869072 869774 869058
2 SDR 20 Nm 810775 869073 869775 869058
3 SDR 20 Nm 810776 869073 869776 869058
3 SDR 100 Nm 810777 869069 869777 869058
4 SDR 200 Nm 810778 869065 869778 869059
4 SDR 300 Nm 810779 869066 869779 869059
2 SDR 200I 810781 869071 869781 869058
3 SDR 50 Nm 810782 869069 869782 869059
3 SDR 140 Nm 810783 869065 869783 869058
CCM 6 Nm 810784 869072 869784 869058
CCM 20 Nm 810785 869073 869785 869058
CCM 100 Nm 810786 869069 869786 869058
CCM 200 Nm 810787 869065 869787 869058
6 SDR 300 Nm 810789 869066 869789 869058
CCM 300 Nm 810792 869066 869792 869058
CCM 250 810793 869066 869793 869058
4 SDR 100 Nm 810797 869069 869797 869058
4 SDR 140 Nm 810798 869065 869798 869058
Grip Kit Description Hex Stem Description
869065 Grip, Long, Replacement Kit for 1 Unit Increments 869058 Hex Stem Lock, Short
869066 Grip, Long Replacement Kit for 2 Unit Increments 869059 Hex Stem Lock, Long
869067 Grip, Long, Replacement Kit for 5 Unit Increments – –
869068 Grip, Long, Replacement Kit for 10 Unit Increments – –
869069 Grip, Long, Replacement Kit for 1/2 Unit Increments – –
869070 Grip, Short, Replacement Kit for 1 Unit Increments – –
869071 Grip, Short, Replacement Kit for 2 Unit Increments – –
869072 Grip, Short, replacement Kit for .1 Unit Increments – –
869073 Grip, Short, Replacement Kit for .2 Unit Increments – –
*Each Grip Kit comes with both Hex Stems. The “Hex Stem Used” column designates which Hex Stem is needed with each wrench.
For kits highlighted in gray, there is a second set screw that is used as a jam nut. That (jam nut) set screw needs to be removed in order to make the calibration adjustment.
Sturtevant Richmont New Metal Grip Conversion Chart
www.srtorque.com
LIT 161 2015 April
555 Kimberly Drive
Carol Stream, IL 60188
Worldwide Direct: +1 847-455-8677
US Only Toll-Free: +1 800-877-1347
Fax: +1 847-455-0347
customerservice@srtorque.com
Tips1. Be sure to exercise the wrench at
least three (3) times prior to testing at both the low and high end of the scale.
2. Align the load point and the center ofthe pillar on the tester.
3. Keep the speed of testing consistent.
4. Be sure to return the tester to theneutral position so the wrench iscompletely released.
5. After testing the wrench on themechanical loader use the sametransducer and test by hand. Yourreadings should be very close.
6. When calibrating the high end ofthe wrench scale, set the wrenchslightly over capacity. The wrenchwill slightly settle down to thedesired capacity. If the wrench has a150 Ft. Lb. capacity calibrate thehigh end for 152 Ft. Lb.
7. Always have the lock knob tightenedor locked for testing. Turn CCW to lock.