Nokia Siemens Networks WCDMA RAN, Rel. RU10, System Library, v. 6
Troubleshooting Node B
DN70580522
Issue 01AApproval Date 2009/09/18
Confidential
2 DN70580522Issue 01A
Troubleshooting Node B
Id:0900d805806e513eConfidential
The information in this document is subject to change without notice and describes only the product defined in the introduction of this documentation. This documentation is intended for the use of Nokia Siemens Networks customers only for the purposes of the agreement under which the document is submitted, and no part of it may be used, reproduced, modified or transmitted in any form or means without the prior written permission of Nokia Siemens Networks. The documentation has been prepared to be used by professional and properly trained personnel, and the customer assumes full responsibility when using it. Nokia Siemens Networks welcomes customer comments as part of the process of continuous development and improvement of the documentation.
The information or statements given in this documentation concerning the suitability, capacity, or performance of the mentioned hardware or software products are given "as is" and all liability arising in connection with such hardware or software products shall be defined conclusively and finally in a separate agreement between Nokia Siemens Networks and the customer. However, Nokia Siemens Networks has made all reasonable efforts to ensure that the instructions contained in the document are adequate and free of material errors and omissions. Nokia Siemens Networks will, if deemed necessary by Nokia Siemens Networks, explain issues which may not be covered by the document.
Nokia Siemens Networks will correct errors in this documentation as soon as possible. IN NO EVENT WILL Nokia Siemens Networks BE LIABLE FOR ERRORS IN THIS DOCUMENTA-TION OR FOR ANY DAMAGES, INCLUDING BUT NOT LIMITED TO SPECIAL, DIRECT, INDI-RECT, INCIDENTAL OR CONSEQUENTIAL OR ANY LOSSES, SUCH AS BUT NOT LIMITED TO LOSS OF PROFIT, REVENUE, BUSINESS INTERRUPTION, BUSINESS OPPORTUNITY OR DATA,THAT MAY ARISE FROM THE USE OF THIS DOCUMENT OR THE INFORMATION IN IT.
This documentation and the product it describes are considered protected by copyrights and other intellectual property rights according to the applicable laws.
The wave logo is a trademark of Nokia Siemens Networks Oy. Nokia is a registered trademark of Nokia Corporation. Siemens is a registered trademark of Siemens AG.
Other product names mentioned in this document may be trademarks of their respective owners, and they are mentioned for identification purposes only.
Copyright © Nokia Siemens Networks 2009. All rights reserved
f Important Notice on Product Safety Elevated voltages are inevitably present at specific points in this electrical equipment. Some of the parts may also have elevated operating temperatures.
Non-observance of these conditions and the safety instructions can result in personal injury or in property damage.
Therefore, only trained and qualified personnel may install and maintain the system.
The system complies with the standard EN 60950 / IEC 60950. All equipment connected has to comply with the applicable safety standards.
The same text in German:
Wichtiger Hinweis zur Produktsicherheit
In elektrischen Anlagen stehen zwangsläufig bestimmte Teile der Geräte unter Span-nung. Einige Teile können auch eine hohe Betriebstemperatur aufweisen.
Eine Nichtbeachtung dieser Situation und der Warnungshinweise kann zu Körperverlet-zungen und Sachschäden führen.
Deshalb wird vorausgesetzt, dass nur geschultes und qualifiziertes Personal die Anlagen installiert und wartet.
Das System entspricht den Anforderungen der EN 60950 / IEC 60950. Angeschlossene Geräte müssen die zutreffenden Sicherheitsbestimmungen erfüllen.
DN70580522 Issue 01A
3
Troubleshooting Node B
Id:0900d805806e513eConfidential
Table of contentsThis document has 313 pages.
Reason for Update. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 271.1 Title . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 281.2 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 281.2.1 Managed Object Class / Hardware Type . . . . . . . . . . . . . . . . . . . . . . . . 281.2.2 Event Type. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 291.2.3 Probable Cause . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 291.2.4 Severity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 291.2.4.1 Fault Escalation Strategy. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 301.2.4.2 Configuration of Alarm Severities . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 301.3 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 311.4 Troubleshooting (LMT). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
2 200506 - Node B system start-up malfunction due to software/hardware problem . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
2.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 322.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 322.3 Troubleshooting (LMT). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
3 200507 - System halt due to software watchdog detected problem . . . 333.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 333.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 333.3 Troubleshooting (LMT). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
4 200508 - System halt due to detected application process error. . . . . . 344.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 344.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 344.3 Troubleshooting (LMT). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
5 200509 - System halt due to detected hardware exception. . . . . . . . . . 355.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 355.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 355.3 Troubleshooting (LMT). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
6 200510 - System halt due to detected software loading malfunction. . . 366.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 366.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 366.3 Troubleshooting (LMT). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
7 200656 - Iub link broke down. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 377.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 377.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 377.3 Troubleshooting (LMT). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
8 200657 - SSCOP sent overrun . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 398.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 398.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 398.3 Troubleshooting (LMT). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
4 DN70580522Issue 01A
Troubleshooting Node B
Id:0900d805806e513eConfidential
9 200658 - Transmit bandwidth limit for NBAP reached . . . . . . . . . . . . . . 409.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 409.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 409.3 Troubleshooting (LMT) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
10 200659 - Core Controller overload protection activated . . . . . . . . . . . . . 4110.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4110.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4110.3 Troubleshooting (LMT) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
11 200660 - SSCOP Dedicated Link send overrun . . . . . . . . . . . . . . . . . . . 4211.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4211.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4211.3 Troubleshooting (LMT) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
12 200661 - SSCOP Common Link send overrun . . . . . . . . . . . . . . . . . . . . 4312.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4312.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4312.3 Troubleshooting (LMT) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
13 200706 - An error occurred in the nbDatabase. . . . . . . . . . . . . . . . . . . . 4413.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4413.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4413.3 Troubleshooting (LMT) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
14 200707 - A warning occurred in the nbDatabase . . . . . . . . . . . . . . . . . . 4614.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4614.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4614.3 Troubleshooting (LMT) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
15 200905 - VSWR alarm Low . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4715.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4715.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4715.3 Troubleshooting (LMT) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
16 200906 - VSWR alarm High . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4916.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4916.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4916.3 Troubleshooting (LMT) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
17 200907 - RX alarm Low . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5117.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5117.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5117.3 Troubleshooting (LMT) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
18 200908 - RX alarm High . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5318.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5318.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5318.3 Troubleshooting (LMT) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53
19 200909 - TMA switched off, but not defective. . . . . . . . . . . . . . . . . . . . . 5519.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5519.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
DN70580522 Issue 01A
5
Troubleshooting Node B
Id:0900d805806e513eConfidential
19.3 Troubleshooting (LMT). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
20 200910 - TMA feeder alarm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5620.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5620.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5620.3 Troubleshooting (LMT). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56
21 200911 - TMA DC alarm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5821.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5821.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5821.3 Troubleshooting (LMT). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58
22 200914 - Fan unit failed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6022.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6022.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6022.3 Troubleshooting (LMT). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61
23 200915 - Site input alarm detected . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6223.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6223.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6223.3 Troubleshooting (LMT). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63
24 200916 - Rack Door open . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6524.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6524.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6524.3 Troubleshooting (LMT). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65
25 200918 - PA combiner interface fault. . . . . . . . . . . . . . . . . . . . . . . . . . . 6625.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6625.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6625.3 Troubleshooting (LMT). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66
26 200919 - Failure in the DC supply of PA . . . . . . . . . . . . . . . . . . . . . . . . 6726.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6726.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6726.3 Troubleshooting (LMT). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67
27 200920 - High temperature of PA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6827.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6827.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6827.3 Troubleshooting (LMT). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69
28 200921 - Over temperature of PA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7028.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7028.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7028.3 Troubleshooting (LMT). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70
29 200922 - RF performance not being met due to bad linearization. . . . . 7229.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7229.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7229.3 Troubleshooting (LMT). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72
30 200923 - Internal failure of PA detected . . . . . . . . . . . . . . . . . . . . . . . . 73
6 DN70580522Issue 01A
Troubleshooting Node B
Id:0900d805806e513eConfidential
30.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7330.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7330.3 Troubleshooting (LMT) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73
31 200924 - Input power level of LPA too high but LPA can still hold its RF specification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74
31.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7431.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7431.3 Troubleshooting (LMT) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74
32 200925 - Input power level of PA too high . . . . . . . . . . . . . . . . . . . . . . . 7532.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7532.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7532.3 Troubleshooting (LMT) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75
33 200926 - CPU failure of baseband card . . . . . . . . . . . . . . . . . . . . . . . . . 7633.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7633.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7633.3 Troubleshooting (LMT) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 76
34 200927 - Volatile memory failure of baseband card . . . . . . . . . . . . . . . . 7734.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7734.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7734.3 Troubleshooting (LMT) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77
35 200928 - Non-volatile memory failure of baseband card . . . . . . . . . . . . 7835.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7835.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7835.3 Troubleshooting (LMT) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 78
36 200929 - DSP failure. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7936.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7936.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7936.3 Troubleshooting (LMT) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79
37 200931 - FPGA failure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8037.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8037.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8037.3 Troubleshooting (LMT) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80
38 200932 - Control FPGA failure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8138.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8138.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8138.3 Troubleshooting (LMT) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81
39 200933 - External timing signal failure . . . . . . . . . . . . . . . . . . . . . . . . . . 8239.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8239.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8239.3 Troubleshooting (LMT) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82
40 200934 - Failure of the RF part of the TRX. . . . . . . . . . . . . . . . . . . . . . . 8340.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8340.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83
DN70580522 Issue 01A
7
Troubleshooting Node B
Id:0900d805806e513eConfidential
40.3 Troubleshooting (LMT). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83
41 200935 - LVDS Failure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8441.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8441.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8441.3 Troubleshooting (LMT). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 84
42 200936 - Local bus failure around the CPU. . . . . . . . . . . . . . . . . . . . . . 8542.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8542.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8542.3 Troubleshooting (LMT). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85
43 200937 - FTP connection failure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8643.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8643.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8643.3 Troubleshooting (LMT). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 86
44 200938 - CRC error during software image check. . . . . . . . . . . . . . . . . 8744.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8744.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8744.3 Troubleshooting (LMT). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 87
45 200939 - Static configuration file CRC check failed. . . . . . . . . . . . . . . . 8845.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8845.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8845.3 Troubleshooting (LMT). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 88
46 200940 - Software activation failed . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8946.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8946.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8946.3 Troubleshooting (LMT). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 89
47 200941 - Internal clock failure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9047.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9047.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9047.3 Troubleshooting (LMT). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 90
48 200942 - Configuration file inconsistent. . . . . . . . . . . . . . . . . . . . . . . . . 9148.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9148.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9148.3 Troubleshooting (LMT). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 91
49 200943 - IOR file inconsistent . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9249.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9249.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9249.3 Troubleshooting (LMT). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92
50 200944 - FTP put failed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9350.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9350.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9350.3 Troubleshooting (LMT). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 93
51 200945 - FTP manage failure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 94
8 DN70580522Issue 01A
Troubleshooting Node B
Id:0900d805806e513eConfidential
51.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9451.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9451.3 Troubleshooting (LMT) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 94
52 200946 - Still alive supervision failure. . . . . . . . . . . . . . . . . . . . . . . . . . . 9552.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9552.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9552.3 Troubleshooting (LMT) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 95
53 200947 - Failure in the DC supply of DUAMCO . . . . . . . . . . . . . . . . . . . 9653.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9653.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9653.3 Troubleshooting (LMT) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 96
54 200948 - CORBA communication failed . . . . . . . . . . . . . . . . . . . . . . . . . 9754.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9754.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9754.3 Troubleshooting (LMT) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 97
55 200949 - Internal CORBA call failed . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9855.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9855.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9855.3 Troubleshooting (LMT) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 98
56 200950 - Timeout for request or modification . . . . . . . . . . . . . . . . . . . . . 9956.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9956.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9956.3 Troubleshooting (LMT) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 99
57 200951 - Status notification undefined . . . . . . . . . . . . . . . . . . . . . . . . . 10057.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10057.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10057.3 Troubleshooting (LMT) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100
58 200952 - Maximum number of resets exceeded. . . . . . . . . . . . . . . . . . 10158.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10158.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10158.3 Troubleshooting (LMT) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 101
59 200953 - CAN bus off . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10259.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10259.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10259.3 Troubleshooting (LMT) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 102
60 200954 - No message response on CAN . . . . . . . . . . . . . . . . . . . . . . . 10360.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10360.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10360.3 Troubleshooting (LMT) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 103
61 200955 - Mount supervision failure. . . . . . . . . . . . . . . . . . . . . . . . . . . . 10461.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10461.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10461.3 Troubleshooting (LMT) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 104
DN70580522 Issue 01A
9
Troubleshooting Node B
Id:0900d805806e513eConfidential
62 200956 - Watch dog timer expired. . . . . . . . . . . . . . . . . . . . . . . . . . . . 10562.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10562.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10562.3 Troubleshooting (LMT). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 105
63 200957 - Internal CAN processing failure . . . . . . . . . . . . . . . . . . . . . . 10663.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10663.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10663.3 Troubleshooting (LMT). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 106
64 200958 - Timer for the reset supervision expired . . . . . . . . . . . . . . . . 10764.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10764.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10764.3 Troubleshooting (LMT). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 107
65 200959 - Missing response from baseband card. . . . . . . . . . . . . . . . . 10865.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10865.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10865.3 Troubleshooting (LMT). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 108
66 200960 - Invalid response from baseband card. . . . . . . . . . . . . . . . . . 10966.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10966.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10966.3 Troubleshooting (LMT). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 109
67 200961 - Firmware download failure . . . . . . . . . . . . . . . . . . . . . . . . . . 11067.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11067.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11067.3 Troubleshooting (LMT). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 110
68 200980 - Invalid MO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11168.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11168.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11168.3 Troubleshooting (LMT). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 111
69 200981 - MO not mounted. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11269.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11269.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11269.3 Troubleshooting (LMT). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 112
70 200982 - Invalid command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11370.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11370.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11370.3 Troubleshooting (LMT). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 113
71 200983 - Invalid parameter in command . . . . . . . . . . . . . . . . . . . . . . . 11471.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11471.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11471.3 Troubleshooting (LMT). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 114
72 200984 - Firmware download access file error . . . . . . . . . . . . . . . . . . 11572.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11572.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 115
10 DN70580522Issue 01A
Troubleshooting Node B
Id:0900d805806e513eConfidential
72.3 Troubleshooting (LMT) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 115
73 200985 - CAN transaction error . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11673.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11673.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11673.3 Troubleshooting (LMT) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 116
74 200986 - Temperature out of range in upper direction . . . . . . . . . . . . . 11774.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11774.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11774.3 Troubleshooting (LMT) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 117
75 200987 - Hardware parameter invalid. . . . . . . . . . . . . . . . . . . . . . . . . . 11975.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11975.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11975.3 Troubleshooting (LMT) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 119
76 200988 - Response unknown . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12076.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12076.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12076.3 Troubleshooting (LMT) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 120
77 200989 - No CORBA proxy available for LRU . . . . . . . . . . . . . . . . . . . 12177.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12177.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12177.3 Troubleshooting (LMT) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 121
78 200990 - No still alive response from LRU . . . . . . . . . . . . . . . . . . . . . . 12278.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12278.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12278.3 Troubleshooting (LMT) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 122
79 200991 - Duplex error . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12379.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12379.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12379.3 Troubleshooting (LMT) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 123
80 200992 - Software error . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12480.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12480.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12480.3 Troubleshooting (LMT) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 124
81 200993 - Unexpected alarm status bit . . . . . . . . . . . . . . . . . . . . . . . . . 12581.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12581.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12581.3 Troubleshooting (LMT) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 125
82 200994 - Hardware Failure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12682.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12682.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12682.3 Troubleshooting (LMT) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 126
83 200995 - High Temperature Limit (Ht3) reached . . . . . . . . . . . . . . . . . 127
DN70580522 Issue 01A
11
Troubleshooting Node B
Id:0900d805806e513eConfidential
83.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12783.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12783.3 Troubleshooting (LMT). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 127
84 200996 - Critical Temperature Limit (Ht4) reached . . . . . . . . . . . . . . . 12984.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12984.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12984.3 Troubleshooting (LMT). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 129
85 200997 - Lower Temperature Limit (Ht0) reached. . . . . . . . . . . . . . . . 13185.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13185.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13185.3 Troubleshooting (LMT). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 131
86 200998 - Temperature out of range in lower direction . . . . . . . . . . . . . 13286.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13286.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13286.3 Troubleshooting (LMT). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 132
87 200999 - Unexpected loss of unlocked LRU . . . . . . . . . . . . . . . . . . . . 13387.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13387.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13387.3 Troubleshooting (LMT). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 133
88 201001 - RET power off. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13588.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13588.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13588.3 Troubleshooting (LMT). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 135
89 201002 - RET feeder alarm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13789.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13789.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13789.3 Troubleshooting (LMT). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 137
90 201003 - RET hardware alarm. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13990.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13990.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13990.3 Troubleshooting (LMT). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 139
91 201004 - ALD communication error . . . . . . . . . . . . . . . . . . . . . . . . . . . 14091.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14091.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14091.3 Troubleshooting (LMT). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 140
92 201005 - RET is not calibrated . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14292.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14292.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14292.3 Troubleshooting (LMT). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 142
93 201006 - RET is not scaled . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14393.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14393.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14393.3 Troubleshooting (LMT). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 143
12 DN70580522Issue 01A
Troubleshooting Node B
Id:0900d805806e513eConfidential
94 201007 - RET lost position . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14494.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14494.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14494.3 Troubleshooting (LMT) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 144
95 201008 - RET received wrong configuration data. . . . . . . . . . . . . . . . . 14595.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14595.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14595.3 Troubleshooting (LMT) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 145
96 201009 - A mounted card is not used to its full capacity. . . . . . . . . . . . 14796.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14796.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14796.3 Troubleshooting (LMT) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 147
97 201010 - An incompatible card is mounted. . . . . . . . . . . . . . . . . . . . . . 14897.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14897.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14897.3 Troubleshooting (LMT) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 148
98 201011 - Alignment of standby CC failed . . . . . . . . . . . . . . . . . . . . . . . 14998.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14998.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14998.3 Troubleshooting (LMT) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 149
99 201012 - Timeout for connection to standby CC . . . . . . . . . . . . . . . . . 15099.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15099.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15099.3 Troubleshooting (LMT) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 150
100 201013 - Connection failure to standby CC . . . . . . . . . . . . . . . . . . . . . 151100.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 151100.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 151100.3 Troubleshooting (LMT) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 151
101 201014 - Standby CC forced to become active due to unreachable active CC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 152
101.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 152101.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 152101.3 Troubleshooting (LMT) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 152
102 201015 - Preparation of data to be aligned has failed . . . . . . . . . . . . . 153102.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 153102.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 153102.3 Troubleshooting (LMT) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 153
103 201016 - Non-fatal internal LVDS failure . . . . . . . . . . . . . . . . . . . . . . . 154103.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 154103.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 154103.3 Troubleshooting (LMT) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 154
104 201017 - Digital input power level too high, but gain reduced . . . . . . . 155104.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 155
DN70580522 Issue 01A
13
Troubleshooting Node B
Id:0900d805806e513eConfidential
104.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 155104.3 Troubleshooting (LMT). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 155
105 201018 - The LRU could not process a message from CC . . . . . . . . . 156105.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 156105.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 156105.3 Troubleshooting (LMT). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 156
106 201019 - Gain below threshold . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 157106.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 157106.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 157106.3 Troubleshooting (LMT). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 157
107 201020 - Loss of single DRIF interface detected. . . . . . . . . . . . . . . . . 158107.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 158107.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 158107.3 Troubleshooting (LMT). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 158
108 201022 - Alignment of file data has failed . . . . . . . . . . . . . . . . . . . . . . 159108.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 159108.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 159108.3 Troubleshooting (LMT). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 159
109 201023 - Bad signal quality of single DRIF interface detected . . . . . . 160109.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 160109.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 160109.3 Troubleshooting (LMT). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 160
110 201024 - Bad signal quality of all DRIF interfaces detected . . . . . . . . 162110.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 162110.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 162110.3 Troubleshooting (LMT). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 162
111 201025 - PID could not be read or is corrupted . . . . . . . . . . . . . . . . . . 164111.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 164111.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 164111.3 Troubleshooting (LMT). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 164
112 201026 - LRU sent illegal parameter . . . . . . . . . . . . . . . . . . . . . . . . . . 165112.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 165112.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 165112.3 Troubleshooting (LMT). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 165
113 201027 - LRU could not process a message from CC containing data from DB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 166
113.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 166113.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 166113.3 Troubleshooting (LMT). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 166
114 201028 - Node B system clock hardware failure . . . . . . . . . . . . . . . . . 168114.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 168114.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 168114.3 Troubleshooting (LMT). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 168
14 DN70580522Issue 01A
Troubleshooting Node B
Id:0900d805806e513eConfidential
115 201029 - MEF blocked . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 169115.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 169115.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 169115.3 Troubleshooting (LMT) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 169
116 201030 - Invalid hardware capacity licensing value . . . . . . . . . . . . . . . 170116.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 170116.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 170116.3 Troubleshooting (LMT) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 170
117 201031 - Wrong combination of licensed cards . . . . . . . . . . . . . . . . . . 171117.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 171117.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 171117.3 Troubleshooting (LMT) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 171
118 201032 - Not all cells are licensed . . . . . . . . . . . . . . . . . . . . . . . . . . . . 172118.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 172118.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 172118.3 Troubleshooting (LMT) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 172
119 201033 - PID could not be read or is corrupted - non-fatal . . . . . . . . . . 173119.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 173119.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 173119.3 Troubleshooting (LMT) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 173
120 201034 - Booster’s Fan unit failed . . . . . . . . . . . . . . . . . . . . . . . . . . . . 174120.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 174120.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 174120.3 Troubleshooting (LMT) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 174
121 201035 - MEF completely blocked . . . . . . . . . . . . . . . . . . . . . . . . . . . . 175121.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 175121.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 175121.3 Troubleshooting (LMT) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 175
122 201036 - RRHs unable to establish communication links with the expected number of PSRs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 176
122.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 176122.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 176122.3 Troubleshooting (LMT) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 176
123 201037 - ALD unspecified error . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 177123.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 177123.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 177123.3 Troubleshooting (LMT) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 177
124 201038 - Resource conflict between CP and OAM . . . . . . . . . . . . . . . 178124.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 178124.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 178124.3 Troubleshooting (LMT) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 178
125 201039 - Inconsistency between hardware license and configuration . 179125.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 179
DN70580522 Issue 01A
15
Troubleshooting Node B
Id:0900d805806e513eConfidential
125.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 179125.3 Troubleshooting (LMT). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 179
126 201040 - Wrong cabling of LRU detected . . . . . . . . . . . . . . . . . . . . . . 180126.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 180126.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 180126.3 Troubleshooting (LMT). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 180
127 201041 - Test channels have been lost . . . . . . . . . . . . . . . . . . . . . . . . 181127.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 181127.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 181127.3 Troubleshooting (LMT). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 181
128 201042 - Incompatible Firmware . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 182128.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 182128.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 182128.3 Troubleshooting (LMT). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 182
129 201043 - Missing software image . . . . . . . . . . . . . . . . . . . . . . . . . . . . 183129.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 183129.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 183129.3 Troubleshooting (LMT). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 183
130 201044 - Non fatal configuration failure . . . . . . . . . . . . . . . . . . . . . . . . 184130.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 184130.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 184130.3 Troubleshooting (LMT). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 184
131 201045 - Fatal hardware error . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 185131.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 185131.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 185131.3 Troubleshooting (LMT). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 185
132 201046 - No ATM connection for OAM Autoconfiguration. . . . . . . . . . 186132.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 186132.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 186132.3 Troubleshooting (LMT). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 186
133 201047 - Fatal BB software failure. . . . . . . . . . . . . . . . . . . . . . . . . . . . 188133.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 188133.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 188133.3 Troubleshooting (LMT). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 188
134 201048 - Non-fatal BB software failure . . . . . . . . . . . . . . . . . . . . . . . . 189134.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 189134.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 189134.3 Troubleshooting (LMT). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 189
135 201049 - Non-fatal DSP failure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 190135.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 190135.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 190135.3 Troubleshooting (LMT). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 190
16 DN70580522Issue 01A
Troubleshooting Node B
Id:0900d805806e513eConfidential
136 201050 - Major hardware failure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 191136.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 191136.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 191136.3 Troubleshooting (LMT) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 191
137 202007 - A scanner could not be initialized . . . . . . . . . . . . . . . . . . . . . 192137.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 192137.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 192137.3 Troubleshooting (LMT) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 192
138 202008 - The temporary measurement results could not be stored . . . 193138.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 193138.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 193138.3 Troubleshooting (LMT) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 193
139 202009 - Unable to request measurement results . . . . . . . . . . . . . . . . 194139.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 194139.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 194139.3 Troubleshooting (LMT) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 194
140 202010 - The ScanCo could not be initialized . . . . . . . . . . . . . . . . . . . 195140.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 195140.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 195140.3 Troubleshooting (LMT) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 195
141 202011 - The final results files could not be generated . . . . . . . . . . . . 196141.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 196141.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 196141.3 Troubleshooting (LMT) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 196
142 202014 - The first sccpchUsageRatio Quality of Service alarm has oc-curred . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 197
142.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 197142.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 197142.3 Troubleshooting (LMT) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 197
143 202015 - The second sccpchUsageRatio Quality of Service alarm has oc-curred . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 198
143.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 198143.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 198143.3 Troubleshooting (LMT) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 198
144 202016 - The first prachUsageRatio Quality of Service alarm has occurred199
144.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 199144.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 199144.3 Troubleshooting (LMT) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 199
145 202017 - The second prachUsageRatio Quality of Service alarm has oc-curred . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 200
145.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 200145.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 200145.3 Troubleshooting (LMT) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 200
DN70580522 Issue 01A
17
Troubleshooting Node B
Id:0900d805806e513eConfidential
146 202018 - The first cpUsageRatio Quality of Service alarm has occurred . 201
146.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 201146.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 201146.3 Troubleshooting (LMT). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 201
147 202019 - The second cpUsageRatio Quality of Service alarm has occurred202
147.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 202147.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 202147.3 Troubleshooting (LMT). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 202
148 202020 - The first prachCrciFailures Quality of Service alarm has occurred203
148.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 203148.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 203148.3 Troubleshooting (LMT). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 203
149 202021 - The second prachCrciFailures Quality of Service alarm has oc-curred. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 204
149.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 204149.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 204149.3 Troubleshooting (LMT). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 204
150 202022 - The first bbUsageRatioLicense Quality of Service alarm has oc-curred. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 205
150.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 205150.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 205150.3 Troubleshooting (LMT). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 205
151 202023 - The second bbUsageRatioLicense Quality of Service alarm has occurred. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 206
151.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 206151.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 206151.3 Troubleshooting (LMT). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 206
152 202024 - The first bbUsageRatioHw Quality of Service alarm has occurred207
152.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 207152.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 207152.3 Troubleshooting (LMT). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 207
153 202025 - The second bbUsageRatioHw Quality of Service alarm has oc-curred. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 208
153.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 208153.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 208153.3 Troubleshooting (LMT). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 208
154 202026 - The first e1Crc Quality of Service alarm has occurred . . . . . 209154.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 209154.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 209154.3 Troubleshooting (LMT). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 209
18 DN70580522Issue 01A
Troubleshooting Node B
Id:0900d805806e513eConfidential
155 202027 - The second e1Crc Quality of Service alarm has occurred . . 211155.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 211155.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 211155.3 Troubleshooting (LMT) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 211
156 202028 - The first vcUsageRatio Quality of Service alarm has occurredA-larm added . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 213
156.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 213156.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 213156.3 Troubleshooting (LMT) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 213
157 202029 - The second vcUsageRatio Quality of Service alarm has occurred214
157.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 214157.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 214157.3 Troubleshooting (LMT) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 214
158 202056 - Loss Of Signal on Physical Link . . . . . . . . . . . . . . . . . . . . . . 215158.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 215158.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 215158.3 Troubleshooting (LMT) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 215
159 202057 - Loss Of Frame on Physical Link . . . . . . . . . . . . . . . . . . . . . . 217159.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 217159.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 217159.3 Troubleshooting (LMT) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 217
160 202058 - Loss Of Cell Delineation on Physical Link . . . . . . . . . . . . . . . 220160.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 220160.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 220160.3 Troubleshooting (LMT) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 220
161 202059 - Alarm Indication Signal on Physical Link . . . . . . . . . . . . . . . . 223161.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 223161.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 223161.3 Troubleshooting (LMT) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 223
162 202060 - Remote Alarm Indication on Physical Link . . . . . . . . . . . . . . 225162.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 225162.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 225162.3 Troubleshooting (LMT) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 225
163 202061 - Loss of Multi Frame Alarm Indication on E1 Physical Link . . 227163.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 227163.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 227163.3 Troubleshooting (LMT) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 227
164 202062 - Line Alarm Indication Signal Indication on STM1 Physical Link .229
164.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 229164.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 229164.3 Troubleshooting (LMT) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 229
DN70580522 Issue 01A
19
Troubleshooting Node B
Id:0900d805806e513eConfidential
165 202063 - Line Remote Defect Indication on STM1 Physical Link . . . . 231165.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 231165.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 231165.3 Troubleshooting (LMT). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 231
166 202064 - Path Loss of Pointer Indication on STM1 Physical Link . . . . 233166.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 233166.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 233166.3 fcTroubleshooting (LMT) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 233
167 202065 - Path Alarm Indication Signal on STM1 Physical Link . . . . . . 235167.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 235167.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 235167.3 Troubleshooting (LMT). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 236
168 202066 - Path Remote Defect Indication on STM1 Physical Link . . . . 237168.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 237168.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 237168.3 Troubleshooting (LMT). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 237
169 202068 - Signal Label Mismatch Indication on STM1 Physical Link . . 239169.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 239169.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 239169.3 Troubleshooting (LMT). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 239
170 202070 - Signal Degrade Indication on STM1 Physical Link. . . . . . . . 240170.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 240170.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 240170.3 Troubleshooting (LMT). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 240
171 202071 - Excessive Bit Error Rate Indication on STM1 Physical Link. 242171.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 242171.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 242171.3 Troubleshooting (LMT). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 242
172 202072 - Alarm Indication Signal on an ATM VC . . . . . . . . . . . . . . . . 244172.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 244172.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 244172.3 Troubleshooting (LMT). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 244
173 202073 - Remote Defect Indication on an ATM VC. . . . . . . . . . . . . . . 246173.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 246173.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 246173.3 Troubleshooting (LMT). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 246
174 202074 - SSCOP Failure Indication on an ATM VC used by ALCAP or NBAP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 248
174.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 248174.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 248174.3 Troubleshooting (LMT). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 248
175 202075 - Alarm Indication Signal on an ATM VP. . . . . . . . . . . . . . . . . 250175.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 250
20 DN70580522Issue 01A
Troubleshooting Node B
Id:0900d805806e513eConfidential
175.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 250175.3 Troubleshooting (LMT) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 250
176 202076 - Remote Defect Indication on an ATM VP . . . . . . . . . . . . . . . 252176.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 252176.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 252176.3 Troubleshooting (LMT) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 252
177 202077 - ALCAP PVC Out Of Service Indication . . . . . . . . . . . . . . . . . 254177.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 254177.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 254177.3 Troubleshooting (LMT) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 254
178 202078 - Loss Of Delay Synchronization on IMA Link . . . . . . . . . . . . . 255178.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 255178.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 255178.3 Troubleshooting (LMT) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 255
179 202079 - Loss Of IMA Frame on IMA Link . . . . . . . . . . . . . . . . . . . . . . 256179.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 256179.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 256179.3 Troubleshooting (LMT) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 256
180 202080 - Remote Failure Indicator on IMA Link . . . . . . . . . . . . . . . . . . 257180.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 257180.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 257180.3 Troubleshooting (LMT) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 257
181 202081 - IMA Tx link is detected as mis-connected . . . . . . . . . . . . . . . 258181.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 258181.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 258181.3 Troubleshooting (LMT) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 258
182 202082 - IMA Rx link is detected as mis-connected . . . . . . . . . . . . . . . 259182.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 259182.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 259182.3 Troubleshooting (LMT) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 259
183 202083 - Tx fault declared at the NE on IMA Link . . . . . . . . . . . . . . . . 260183.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 260183.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 260183.3 Troubleshooting (LMT) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 260
184 202084 - Rx fault declared at the NE on IMA Link . . . . . . . . . . . . . . . . 261184.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 261184.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 261184.3 Troubleshooting (LMT) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 261
185 202085 - FE has reported Tx-Unusable on IMA Link . . . . . . . . . . . . . . 262185.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 262185.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 262185.3 Troubleshooting (LMT) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 262
DN70580522 Issue 01A
21
Troubleshooting Node B
Id:0900d805806e513eConfidential
186 202086 - FE has reported Rx-Unusable on IMA Link . . . . . . . . . . . . . 263186.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 263186.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 263186.3 Troubleshooting (LMT). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 263
187 202087 - Startup FE reported on IMA Group. . . . . . . . . . . . . . . . . . . . 264187.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 264187.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 264187.3 Troubleshooting (LMT). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 264
188 202088 - Config Abort reported on IMA Group . . . . . . . . . . . . . . . . . . 265188.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 265188.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 265188.3 Troubleshooting (LMT). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 265
189 202089 - Config Abort FE reported on IMA Group . . . . . . . . . . . . . . . 266189.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 266189.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 266189.3 Troubleshooting (LMT). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 266
190 202090 - Insufficient Links reported at NE on IMA Group . . . . . . . . . . 267190.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 267190.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 267190.3 Troubleshooting (LMT). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 267
191 202091 - Insufficient Links at FE reported on IMA Group . . . . . . . . . . 268191.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 268191.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 268191.3 Troubleshooting (LMT). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 268
192 202092 - Group Blocked at FE reported on IMA Group. . . . . . . . . . . . 269192.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 269192.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 269192.3 Troubleshooting (LMT). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 269
193 202093 - Timing Synch error reported on IMA Group . . . . . . . . . . . . . 270193.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 270193.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 270193.3 Troubleshooting (LMT). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 270
194 202095 - The Near End IMA has detected an invalid version set by the Far End . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 271
194.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 271194.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 271194.3 Troubleshooting (LMT). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 271
195 202097 - Loss of Continuity detected on an ATM VP . . . . . . . . . . . . . 272195.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 272195.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 272195.3 Troubleshooting (LMT). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 272
196 202098 - CRC4 not used by FE reported on E1TTP . . . . . . . . . . . . . . 273196.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 273
22 DN70580522Issue 01A
Troubleshooting Node B
Id:0900d805806e513eConfidential
196.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 273196.3 Troubleshooting (LMT) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 273
197 202106 - Software activation failed. . . . . . . . . . . . . . . . . . . . . . . . . . . . 274197.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 274197.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 274197.3 Troubleshooting (LMT) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 274
198 202107 - Database activation failed . . . . . . . . . . . . . . . . . . . . . . . . . . . 275198.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 275198.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 275198.3 Troubleshooting (LMT) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 275
199 202108 - Reliable software started without prior explicit activation . . . 276199.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 276199.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 276199.3 Troubleshooting (LMT) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 276
200 202109 - Reliable database started without prior explicit activation . . . 277200.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 277200.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 277200.3 Troubleshooting (LMT) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 277
201 202358 - CAN received an unexpected message . . . . . . . . . . . . . . . . 278201.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 278201.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 278201.3 Troubleshooting (LMT) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 278
202 202360 - A necessary resource is missed . . . . . . . . . . . . . . . . . . . . . . 279202.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 279202.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 279202.3 Troubleshooting (LMT) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 279
203 202406 - ALCAP protocol error. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 280203.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 280203.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 280203.3 Troubleshooting (LMT) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 280
204 202431 - ALCAP transaction to RNC initiated by transport timed out . 281204.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 281204.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 281204.3 Troubleshooting (LMT) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 281
205 202432 - ALCAP transaction to RNC initiated by NBAP timed out . . . . 282205.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 282205.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 282205.3 Troubleshooting (LMT) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 282
206 202433 - Configuration misalignment between RNC and CPA . . . . . . 283206.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 283206.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 283206.3 Troubleshooting (LMT) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 283
DN70580522 Issue 01A
23
Troubleshooting Node B
Id:0900d805806e513eConfidential
207 202434 - RNC Establish Request message received which is invalid or cannot be handled . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 284
207.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 284207.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 284207.3 Troubleshooting (LMT). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 284
208 202435 - CPA to RNC communication (socket) problems. . . . . . . . . . 285208.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 285208.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 285208.3 Troubleshooting (LMT). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 285
209 202506 - Node B system clock in holdover mode . . . . . . . . . . . . . . . . 286209.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 286209.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 286209.3 Troubleshooting (LMT). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 286
210 202507 - Node B system clock in medium accuracy . . . . . . . . . . . . . . 288210.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 288210.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 288210.3 Troubleshooting (LMT). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 288
211 262041 - System call unsuccessful . . . . . . . . . . . . . . . . . . . . . . . . . . . 290211.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 290211.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 290211.3 Troubleshooting (LMT). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 290
212 262042 - Unexpected software error . . . . . . . . . . . . . . . . . . . . . . . . . . 291212.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 291212.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 291212.3 Troubleshooting (LMT). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 291
213 262043 - Error from device driver received . . . . . . . . . . . . . . . . . . . . . 292213.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 292213.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 292213.3 Troubleshooting (LMT). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 292
214 262044 - Not enough memory to initialize software. . . . . . . . . . . . . . . 293214.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 293214.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 293214.3 Troubleshooting (LMT). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 293
215 262045 - Memory allocation failure . . . . . . . . . . . . . . . . . . . . . . . . . . . 294215.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 294215.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 294215.3 Troubleshooting (LMT). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 294
216 262046 - Unexpected exception handling . . . . . . . . . . . . . . . . . . . . . . 295216.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 295216.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 295216.3 Troubleshooting (LMT). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 295
217 262047 - Uncaught exception handling . . . . . . . . . . . . . . . . . . . . . . . . 296217.1 Failure Event Report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 296
24 DN70580522Issue 01A
Troubleshooting Node B
Id:0900d805806e513eConfidential
217.2 Error Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 296217.3 Troubleshooting (LMT) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 296
218 Appendix . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 297218.1 Fault management in the NB/RSxxx. . . . . . . . . . . . . . . . . . . . . . . . . . . 297218.1.1 Equipment fault management . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 300218.1.2 Transport network fault management . . . . . . . . . . . . . . . . . . . . . . . . . . 301218.2 Mapping of NB/RSxxx alarms to NetAct alarms . . . . . . . . . . . . . . . . . . 304
DN70580522 Issue 01A
25
Troubleshooting Node B
Id:0900d805806e513eConfidential
List of tablesTable 1 Mapping of NB/RSxxx alarms to NetAct alarms . . . . . . . . . . . . . . . . . 304
26 DN70580522Issue 01A
Troubleshooting Node B
Id:0900d805806241c3Confidential
Reason for Update
Reason for UpdateIssue History
Note that the issue numbering system is changing. For more information, see Guide to WCDMA RAN Documentation.
DetailsAll– First issue for new release.
201047 - Fatal BB software failure (133)
– Severity of 201047 failure has been updated.
Issue Number Date of Issue Reason for Update
01 09/2008 First issue for new release.
01A 09/2009 Severity of 201047 failure has been updated.
DN70580522 Issue 01A
27
Troubleshooting Node B Introduction
Id:0900d8058022b398Confidential
1 Introductiong This document is prepared as a standard edition that may include descriptions not
applying to your system.
The goal of this manual is to describe all alarms and system information which can be generated by the Node B. The “Troubleshooting Node B” manual provides information on handling these alarms via the LMT.
A description of the general UTRAN maintenance concept and an example of how to solve an alarm are provided in this manual’s “Appendix”, section “Solving and clearing an alarm”.
The software attempts to provide a precise error description for each alarm containing all information for the operator and manufacturer in order to rapidly localize, investigate and eliminate the fault. There is no relation between the number of described faults and their frequency of occurrence in the system.
Error ceased messages clear all alarms for a specific probable cause of one object. Whenever a diagnosis of a faulty object fails, the operator has to replace the faulty module (specified in the test report) following the procedure described in the according maintenance manual.
This manual is organized according to the error-IDs where each one forms a chapter with: • Title • Failure Event Report • Error Description • Troubleshooting (LMT)
Suppression of toggling Node B alarmsOperators at the Node B can reduce the amount of alarms at the Itf-B interface to the really important alarms by means of alarm suppression. Applying alarm suppression, operators can prevent the system from alarms which fill the alarm buffers but do not provide further important information. Alarms which are raised and cleared in short periods (toggling alarms) and which do not give more detailed information on fault analysis and fault location will thus be suppressed.
The toggling condition is indicated by a specifically modified “additionalText”.
To achieve the suppression of toggling alarms, a specific algorithm is used. This algo-rithm detects toggling alarms as such and suppresses the toggling alarm notifications after a specified time. The suppression algorithm works as follows:
If the managed object (MO) raises the same alarm (see: Failure Event Report) for a specified number of times (x) within a predefined period (y seconds), the system assigns the ’Alarm Toggling Condition’ to this specific alarm in this specific MO. As long as the ’Alarm Toggling Condition’ is active, each single alarm notification and alarm clearance message is suppressed.
The following two scenarios lead to the cancellation of the ’Alarm Toggling Condition’: • Case 1: The alarm has not been present for a specified period (z seconds).
The ’Alarm Toggling Condition’ is cleared and the system sends an alarm clearance message, indicating the end of the ’Alarm Toggling Condition’.
28 DN70580522Issue 01A
Troubleshooting Node B
Id:0900d8058022b398Confidential
Introduction
• Case 2: The previously toggling alarms becomes stable, i.e. non-toggling, for a specified period (z seconds).The ’Alarm Toggling Condition’ is cleared (see also Case 1) and the relevant alarm message of the specific alarm is sent to the management system.
Operators can enable or disable the suppression of toggling alarms in the Node B, via a CLI command by setting the togglingSuppressed parameter. This parameter specifies whether suppression of toggling alarms is active (TRUE) or not (FALSE).
Set to FALSE means that the suppression function is generally disabled for all external and internal alarms.
Operators can define or change toggling alarm conditions for NodeB2 to reduce the amount of alarms via a CLI command. Conditions for external toggling data and internal toggling data can be defined.
Example:Configure the toggling condition (TC: x=occurence, y=detection time, z=stable condition time) for following alarms: • External alarm (incoming port 0) and TC (x,y,z = 3, 300, 600) • External alarm (incoming port 3) and TC (x,y,z = 2, 100, 100) • Internal alarm with ID = 200908, which is mapped to the error string “RX alarm High”
and TC (x,y,z = 4, 300, 900)
In addition to the built-in default list, one modifiable list contains those alarms the operator wants to suppress in case of the toggling condition. This list also contains the related parameters, i.e. number of occurrences (x), period (y seconds), period of stable toggling (z seconds).
Detailed information about the actions mentioned above is available in “Node B Service Terminal Commands” reference manual.
1.1 TitleComposed of error-ID and error string
1.2 Failure Event ReportContains the following details: • Managed Object Class / Hardware Type • Event Type • Probable Cause • Severity
1.2.1 Managed Object Class / Hardware TypeThe managed object class / hardware type identifies the managed object class of the fault or error.
In the “Troubleshooting Node B” manual, an asterisk (’*’) symbol in the related field of the failure event report means that potentially any managed object class / hardware type can report this alarm.
DN70580522 Issue 01A
29
Troubleshooting Node B Introduction
Id:0900d8058022b398Confidential
1.2.2 Event TypeThe Event Type may have these possible values: • communicationsAlarm
An alarm of this type is principally associated with the procedures and/or processes required to convey information from one network node to another.
• environmentalAlarmAn alarm of this type is principally associated with a condition relating to an enclo-sure in which the equipment resides.
• equipmentAlarmAn alarm of this type is principally associated with an equipment fault.
• qualityOfServiceAlarmAn alarm of this type is principally associated with a degradation in the quality of a service and is issued as a result of performance measurements.QoS alarms help the operator to– Evaluate and gauge thresholds for performance management– Modify (add, remove, activate, deactivate) thresholds
• processingErrorAlarmAn alarm of this type is principally associated with a software or processing fault.
1.2.3 Probable CauseIdentifies the probable cause of the fault or error. The probable cause is taken out of a predefined set of values defined for each alarm type.
1.2.4 SeverityAccording to the CCITT Rec. X.733 all alarm notifications produced in switching systems have to be classified concerning the severity of their impact on the NE’s (Network Element) functionality.
The severity assigned to a specific alarm has one of the following values: • critical
The fault condition affects the ability to provide service. Immediate corrective action is required because (for example) a managed object has completely gone out of service.
• majorThe fault condition affects the ability to provide service. Urgent corrective action is required because (for example) a managed object has suffered from a severe deg-radation of its capabilities.
• minorThe fault condition does not affect the service as a whole. Corrective action is rec-ommended to prevent a more serious fault.
• warningA fault has been detected which potentially affects service. No significant effects have occurred. Action should be taken to further diagnose and (if necessary) correct the problem in order to prevent it from developing into a more serious service affect-ing fault.
30 DN70580522Issue 01A
Troubleshooting Node B
Id:0900d8058022b398Confidential
Introduction
1.2.4.1 Fault Escalation StrategySome specific problems are handled according to the so-called “Fault Escalation Strat-egy”. This strategy consists of the following rules: • If the object raises the corresponding alarm for the first time, the alarm’s severity is
WARNING. • Upon each occurrence of this alarm, a dedicated escalation counter is incremented
and a corresponding dedicated escalation timer is (re-)started. • If the object operates normally for a specific period of time (the expiration period of
the escalation timer), i.e. if the object does not raise the same alarm again until the escalation timer expires, the escalation counter is reset.If the object raises the same alarm after expiry of the escalation timer, the alarm’s severity will be WARNING again.
• If the object raises the same alarm a predefined number of times without having operated normally for the escalation counter’s expiration period or longer, i.e. if the escalation counter crosses a predefined threshold, the severity will change from WARNING to a predefined final alarm severity.The alarm’s final severity is then set in the Failure Event Report. This manual describes the alarm’s final severity in the failure event report of the relevant alarm.
1.2.4.2 Configuration of Alarm SeveritiesThe operator can configure the severities of some alarms to either minor, major, or crit-ical, thus achieving a satisfying adaptation to actual needs. To adapt the alarm severity, the Node B’s database (DB) has to be changed. The FaultMng MOC in the Node B’s DB contains the severities parameter which is a list of all modified alarm severities. Several instances within this list can be created at the LMT. Each instance provides the following operator-configurable attributes: • Error ID of the alarm to be modified • ID of the MOC related to the alarm for which the severity is to be changed • Severity
Each instance within the severities parameter is evaluated by the Node B’s software (SW). Instances with MOC IDs or error IDs incompatible to the current Node B SW load are ignored.
To change the severity of an alarm, the following procedure has to be applied:1. Upload the DB to the LMT.
Use the TREE View window of the LMT or apply the uploadDataInitiate command to the relevant Osu managed object.
2. Modify the DB with the help of an XML editor or using scripts.Proceed according to the “Node B Database Editing Guide”.The following possibilities exist at the LMT:– Adding or removing an instance to or from, respectively, the severities list.– Modifying an existing instance within the list.
3. Download the modified DB.Use the TREE View window of the LMT or apply the downloadDataInitiate command to the relevant Osu managed object.
4. Activate the downloaded DB.Use the TREE View window or the Osu “activate”, nodeBDatabaseVersionType command.
DN70580522 Issue 01A
31
Troubleshooting Node B Introduction
Id:0900d8058022b398Confidential
For more information about DB parameters, refer to the “Node B Database Description”.
The severity assignment for a specific alarm is determined by the following sources, listed in descending priority:1. Severity setting for a particular managed object class (MOC), such as ExtEquipIn or
Scanner.2. Severity setting in the severities list of the Node B’s FaultMng MOI.3. Default built-in severity.
g NOTEThe severities attribute will be considered only for alarms that represent a con-dition for which a corresponding clearance event exists. In contrast, alarms that rep-resent only one single event, will always be sent with severity warning.
1.3 Error DescriptionDescribes the probable cause of the error concisely.
1.4 Troubleshooting (LMT)Describes the actions the operator must perform to attempt to solve the problem.
Collect Info for AssistanceIn some cases it is necessary to get support from customer services in order to isolate the fault. Prior to contacting the Technical Assistance Center (TAC) pay attention to the following questions and tasks: • Description of malfunction. • What is the suspected origin of the error? • What are the functional and hardware states of the affected system? • What are the issues of the affected boards? Check HW and FW states. • Observed system activities? • External influences (power supply, environment)? • What has been done (customer, local service staff)? • Exact time of error: synchronize the time stamp of all log files, if possible. • Save the database of the affected NE. • Save the IDF (Inventory Data File) of the affected NE. • Upload the log file of the affected NE.
The LMT provides a feature to upload diagnosis data from the Node B. The result of the diagnosis data upload is a zip file which should be attached to any fault report. The zip file contains information on the exact time of occurrence of the error, the database and the inventory data file (IDF) of the affected network element and the log file. For details about the diagnosis data upload, refer to the “Using Node B Service Terminal” guideline.
32 DN70580522Issue 01A
Troubleshooting Node B
Id:0900d8058022b3a0Confidential
200506 - Node B system start-up malfunction due to software/hardware problem
2 200506 - Node B system start-up malfunction due to software/hardware problem
2.1 Failure Event Report
2.2 Error DescriptionThe Node B system start-up is maintained by a dedicated software subsystem (Mas-terServiceTask: MST). Any error encountered during initialization of this subsystem will generate this fault report. The affected Node B Core Controller is not available. Probable reasons for these conditions are problems related either to hardware (e.g.: memory problem, input/output malfunction) or operating system environment. This condition leads to a recovery reset of the whole Node B.
If the fault report relates to a HW problem, troubleshooting might require detailed knowl-edge of the Node B hardware structure (memory, boot system, ...). If the fault report relates to a SW problem, troubleshooting might require direct access to the Node B's operating system console.
2.3 Troubleshooting (LMT)Due to the imponderable system behavior in such cases there is no statement about further system operations. Contact the technical assistance center (TAC) to get support in isolating the fault. For suitable preparation save the error symptoms as described in “Collect Info for Assistance”. Log files need to be analyzed and specific measures must be taken which are out of the operator’s scope.
Managed Object Class / Hardware Type:
Osu
Event Type: processingErrorAlarm
Probable Cause: ApplicationSubsystemFailure
Severity: critical
DN70580522 Issue 01A
33
Troubleshooting Node B 200507 - System halt due to software watchdog detect-ed problem
Id:0900d8058022b3a8Confidential
3 200507 - System halt due to software watchdog detected problem
3.1 Failure Event Report
3.2 Error DescriptionThis problem reports a situation, where the software health observation system has detected a missing health indication from any Node B software subsystem. The affected subsystem malfunction might (dependent of subsystem and error cause) be already noticeable by generated fault reports from it's own scope. This condition leads to a recovery reset of the whole Node B. The affected Node B Core Controller is temporary not available. This information has to be analyzed to find the malfunction originator. Due to the recovery reset, only the system log files could be used for 'post' analysis.
The probable reason for this alarm is a software problem.
3.3 Troubleshooting (LMT)Contact the technical assistance center (TAC) to get support in isolating the fault. For suitable preparation save the error symptoms as described in “Collect Info for Assis-tance”. Log files need to be analyzed and specific measures must be taken which are out of the operator’s scope.
Managed Object Class / Hardware Type:
Osu
Event Type: processingErrorAlarm
Probable Cause: WatchDogTimerExpired
Severity: critical
34 DN70580522Issue 01A
Troubleshooting Node B
Id:0900d8058022b3aeConfidential
200508 - System halt due to detected application pro-cess error
4 200508 - System halt due to detected applica-tion process error
4.1 Failure Event Report
4.2 Error DescriptionThis problem reports a situation, where the software health observation system has detected a 'dead' Node B software subsystem. The affected subsystem (generally) could not be indicated by generated fault reports from it's own scope, but this problem report contains information about the originator of the error. This condition leads to a recovery reset of the whole Node B. The affected Node B Core Controller is temporarily not available. Due to the recovery reset, only the system log files could be used for 'post' analysis.
The probable reason for this alarm is a software problem.
4.3 Troubleshooting (LMT)Contact the technical assistance center (TAC) to get support in isolating the fault. For suitable preparation save the error symptoms as described in “Collect Info for Assis-tance”. Log files need to be analyzed and specific measures must be taken which are out of the operator’s scope.
Managed Object Class / Hardware Type:
Osu
Event Type: processingErrorAlarm
Probable Cause: SoftwareProgramAbnormallyTermi-nated
Severity: critical
DN70580522 Issue 01A
35
Troubleshooting Node B 200509 - System halt due to detected hardware excep-tion
Id:0900d8058022b3b4Confidential
5 200509 - System halt due to detected hardware exception
5.1 Failure Event Report
5.2 Error DescriptionThis problem reports a situation, where the software health observation system has detected an 'unexpected' signal by the Node B hardware. This will be just logged by the observation system. This problem report contains information about the signal origina-tor. This condition leads to a recovery reset of the whole Node B. The affected Node B Core Controller is temporarily not available. Due to the recovery reset, only the system log files could be used for 'post' analysis.
5.3 Troubleshooting (LMT)Contact the technical assistance center (TAC) to get support in isolating the fault. For suitable preparation save the error symptoms as described in “Collect Info for Assis-tance”. Log files need to be analyzed and specific measures must be taken which are out of the operator’s scope.
Managed Object Class / Hardware Type:
Osu
Event Type: communicationsAlarm
Probable Cause: VendorSpecific
Severity: critical
36 DN70580522Issue 01A
Troubleshooting Node B
Id:0900d8058022b3bcConfidential
200510 - System halt due to detected software loading malfunction
6 200510 - System halt due to detected software loading malfunction
6.1 Failure Event Report
6.2 Error DescriptionThis problem reports a situation, where the system loader detects a failure during software loading. This problem report contains information about the name of the failed software component. If the malfunction relates to a HW problem, it might be necessary to replace the addressed card. If the malfunction relates to a software problem, it might be solved by the recovery mechanisms of the software management subsystem (ISW). This condition leads to a recovery reset of the whole Node B. The affected Node B Core Controller is temporarily not available. Due to the recovery reset, only the system log files could be used for 'post' analysis.
6.3 Troubleshooting (LMT)1. Try to reset the addressed card.2. If there is a hardware failure, replace the addressed card.
Replacement must be done according to the “Replacing Node B Units” manual, “Tasklist”.
3. It there is a software failure, contact the technical assistance center (TAC) to get support in isolating the fault. For suitable preparation save the error symptoms as described in “Collect Info for Assistance”. Log files need to be analyzed and specific measures must be taken which are out of the operator’s scope.
Managed Object Class / Hardware Type:
Osu
Event Type: processingErrorAlarm
Probable Cause: VendorSpecific
Severity: critical
DN70580522 Issue 01A
37
Troubleshooting Node B 200656 - Iub link broke down
Id:0900d8058022b3c4Confidential
7 200656 - Iub link broke down
7.1 Failure Event Report
7.2 Error DescriptionAn existing ATM connection between CRNC (controlling RNC) and Node B (Iub link) is broken because the CRNC is down, the cable has been plugged off or is broken. There-fore the Node B performs a reset.
The following subsequent alarms may also be initiated depending on the used interface type (E1/J1/T1, STM-1/OC-3):
• 202056 - Loss Of Signal on Physical Link • 202057 - Loss Of Frame on Physical Link • 202058 - Loss Of Cell Delineation on Physical Link • 202059 - Alarm Indication Signal on Physical Link • 202060 - Remote Alarm Indication on Physical Link • 202061 - Loss of Multi Frame Alarm Indication on E1 Physical Link • 202062 - Line Alarm Indication Signal Indication on STM1 Physical Link • 202063 - Line Remote Defect Indication on STM1 Physical Link • 202064 - Path Loss of Pointer Indication on STM1 Physical Link • 202068 - Signal Label Mismatch Indication on STM1 Physical Link • 202070 - Signal Degrade Indication on STM1 Physical Link • 202071 - Excessive Bit Error Rate Indication on STM1 Physical Link • 202072 - Alarm Indication Signal on an ATM VC • 202073 - Remote Defect Indication on an ATM VC • 202074 - SSCOP Failure Indication on an ATM VC used by ALCAP or NBAP • 202075 - Alarm Indication Signal on an ATM VP • 202076 - Remote Defect Indication on an ATM VP • 202077 - ALCAP PVC Out Of Service Indication
The “Iub link broke down” alarm may be caused by:1. A failure in the RNC. In this case alarms from the RNC are additionally active.2. A failure of the link equipment or in the cable connection between Node B and link
equipment (LE).Usually the Node B is connected to the RNC or each other (Iub interface) via link equipment (LE) and in some rare cases by direct lines. If LE is involved the operation and maintenance system of this network has to be used for getting information about the state and status of the relevant network element (NE).Link equipment thus comprises network components such as SDH/PDH multiplex-ers, ATM switches, or repeaters.
Managed Object Class / Hardware Type:
Cc
Event Type: equipmentAlarm
Probable Cause: LinkFailure
Severity: critical
38 DN70580522Issue 01A
Troubleshooting Node B
Id:0900d8058022b3c4Confidential
200656 - Iub link broke down
3. A failure within the OVPT or the IUBCON if an E1/J1/T1 interface is used.4. A failure in the CC (refer to 200994 - Hardware Failure). In this case, other CC initi-
ated alarms are additionally active.
The affected Node B is not working. All services will be interrupted. All cells will be lost.
7.3 Troubleshooting (LMT) • If RNC alarms for the Iub link to the affected Node B are reported to the RC concen-
trate the fault clearance actions on these alarms first. • Is the LE, which is connected to the relevant port, reporting an equipment alarm?
– If an equipment alarm at the LE is present try to fix this fault first which probably also eliminates the Iub link broke down alarm.
• Check the cable connections:
1. With regard to E1/J1/T1 lines check the OVPT or IUBCONElectrical Iub lines (E1/J1/T1) are connected to the Node B using an OVPT (over-voltage protection and tracer module) equipped with surge arresters or an IUBCON (Iub connector). Both are available for coax and symmetrical cables.– Check surge arresters at OVPT and replace a defective one if necessary– Replace OVPT or IUBCON if no other reason was found
2. With regard to optical STM-1/OC-3 lines
Check for:– Proper connection at the LE (good contact, clean optical connector)– Proper connection at the Node B (good contact, clean optical connector)– Undamaged cable between Node B and LE respectively other Node B or RNC
• Is there also an equipment alarm of the Core Controller (CC) in the reporting Node B present?Using the ALARM View window of the LMT:– Click on the “Alarm View” button or use the shortcut key Ctrl + A
– Use the filter and sort function to concentrate on CC alarmsIf an equipment alarm of the CC is present try to fix this fault first which probably also eliminates the Iub link broke down alarm.
!WARNING: Radiation from laser devices (EN 60825/IEC 60825).
Damage of health may occur.
To avoid damage to health, you must observe the regulations regarding protection against radiation from laser devices (EN 60825/IEC 60825). • You must always use dedicated laser-protective goggles. • Never look into open fiber-optic cable ends, as this may damage your eyes.
DN70580522 Issue 01A
39
Troubleshooting Node B 200657 - SSCOP sent overrun
Id:0900d8058022b3caConfidential
8 200657 - SSCOP sent overrun
8.1 Failure Event Report
8.2 Error DescriptionNode B’s SSCOP is not able to transmit the messages to the CRNC (controlling RNC) since the configured bandwidth on this link is too low. Therefore, the Node B performs an automatic reset.
8.3 Troubleshooting (LMT)Contact the technical assistance center (TAC) to get support in isolating the fault. For suitable preparation save the error symptoms as described in “Collect Info for Assis-tance”. Log files need to be analyzed and specific measures must be taken which are out of the operator’s scope.
Managed Object Class / Hardware Type:
Cc
Event Type: equipmentAlarm
Probable Cause: LinkFailure
Severity: critical
40 DN70580522Issue 01A
Troubleshooting Node B
Id:0900d8058022b3d0Confidential
200658 - Transmit bandwidth limit for NBAP reached
9 200658 - Transmit bandwidth limit for NBAP reached
9.1 Failure Event Report
9.2 Error DescriptionUnder conditions with high traffic, the NBAP bandwidth set at the reporting Node B’s Iub interface may not be sufficient. If the high-traffic condition persists, the Node B will start dropping messages.
This alarm therefore indicates a general lack of bandwidth to send messages at the Node B’s Iub interface. In other words, the Node B’s transmit bandwidth for NBAP con-nections toward the RNC has reached its limit and the message buffers are exhausted.
The Node B then started overload defence actions. This may affect service quality because dedicated measurement reports will be dropped and RL setup or reconfigura-tion attempts will be rejected.
The reporting Node B continues operation. Service quality, however, is decreased. The increased traffic thus requires appropriate settings for the transmit bandwidth at the Node B’s Iub interface. In other words, the Node B’s database (DB) settings have to be revised and the transmit bandwith at the Iub interface has to be increased.
9.3 Troubleshooting (LMT) Take the following measures to clear this alarm and to prevent this overload condition in the future:1. Revise the reporting Node B’s DB settings in such a way that the NBAP transmit
bandwidth is increased.Increase both the ingress and the egress peak cell rate to an identical value, using the following commands:– TrafficDescriptor “Set peakCellRateIngress”– TrafficDescriptor “Set peakCellRateEgress”
2. If the first action did not clear the cause for this alarm, contact the technical assis-tance center (TAC) to get support in isolating the fault. For suitable preparation save the error symptoms as described in “Collect Info for Assistance”. Log files need to be analyzed and specific measures must be taken which are out of the operator’s scope.
Managed Object Class / Hardware Type:
NodeBFddE
Event Type: qualityOfServiceAlarm
Probable Cause: SystemResourcesOverload
Severity: minor
DN70580522 Issue 01A
41
Troubleshooting Node B 200659 - Core Controller overload protection activated
Id:0900d8058022b3d8Confidential
10 200659 - Core Controller overload protection activated
10.1 Failure Event Report
10.2 Error DescriptionA situation with peak load has occurred in the reporting Node B. Due to this situation, the Node B may activate an overload protection. Overload protection is a defence action of the Node B to maintain stable operation.
In fact, the reporting Node B’s core controller (CC) CPU capacity has reached its limit. As a consequence, RL setup or reconfiguration attempts will be rejected. Service quality is decreased.
The causes for the Node B’s high CPU load needs to be investigated.
10.3 Troubleshooting (LMT) Take the following measures to clear the alarm cause:1. First, investigate the causes for the high CC load.2. Contact the technical assistance center (TAC) to get support in isolating the fault.
For suitable preparation save the error symptoms as described in “Collect Info for Assistance”. Log files need to be analyzed and specific measures must be taken which are out of the operator’s scope.
Managed Object Class / Hardware Type:
NodeBFddE
Event Type: qualityOfServiceAlarm
Probable Cause: SystemResourcesOverload
Severity: minor
42 DN70580522Issue 01A
Troubleshooting Node B
Id:0900d8058022b3deConfidential
200660 - SSCOP Dedicated Link send overrun
11 200660 - SSCOP Dedicated Link send overrun
11.1 Failure Event Report
11.2 Error DescriptionThe bandwidth configured on the suspected link is too low. The Node B’s SSCOP is therefore not able to transmit messages over the NBAPDedicated link (“Communication Context Control” port, see usedByAttribute parameter) to the controlling RNC (CRNC).
As a consequence, the Node B performs an automatic reset.
11.3 Troubleshooting (LMT)Take the following measures to solve the reported problem:1. Make sure to adapt the link capacity to the expected traffic at this particular Node B.
The referenced VcCTP which supports the suspected link (VcTTP, see connectivity-Pointer parameter) points to a TrafficDescriptor object via the trafficDescriptor-Pointer parameter. This TrafficDescriptor object has to be configured as follows:– serviceCategory=“CBR”– peakCellRateIngress and peakCellRateEgress must have identical values☞ Also check whether the link capacity problem can be verified, using appropriate
performance measurements (PMs).2. If the problem persists after adapting the link capacity, contact the technical assis-
tance center (TAC) to get support in isolating the fault. For suitable preparation save the error symptoms as described in “Collect Info for Assistance”. Log files need to be analyzed and specific measures must be taken which are out of the operator's scope.
Managed Object Class / Hardware Type:
Cc
Event Type: equipmentAlarm
Probable Cause: LinkFailure
Severity: critical
DN70580522 Issue 01A
43
Troubleshooting Node B 200661 - SSCOP Common Link send overrun
Id:0900d8058022b3e4Confidential
12 200661 - SSCOP Common Link send overrun
12.1 Failure Event Report
12.2 Error DescriptionThe bandwidth configured on the suspected link is too low. The Node B’s SSCOP is therefore not able to transmit messages over the NBAPCommon link (“Node B Control” port, see usedByAttribute parameter) to the controlling RNC (CRNC).
As a consequence, the Node B performs an automatic reset.
12.3 Troubleshooting (LMT)Take the following measures to solve the reported problem:1. Make sure to adapt the link capacity to the expected traffic at this particular Node B.
The referenced VcCTP which supports the suspected link (VcTTP, see connectivity-Pointer parameter) points to a TrafficDescriptor object via the trafficDescriptor-Pointer parameter. This TrafficDescriptor object has to be configured as follows:– serviceCategory=“CBR”– peakCellRateIngress and peakCellRateEgress must have identical values☞ Also check whether the link capacity problem can be verified, using appropriate
performance measurements (PMs).2. If the problem persists after adapting the link capacity, contact the technical assis-
tance center (TAC) to get support in isolating the fault. For suitable preparation save the error symptoms as described in “Collect Info for Assistance”. Log files need to be analyzed and specific measures must be taken which are out of the operator's scope.
Managed Object Class / Hardware Type:
Cc
Event Type: equipmentAlarm
Probable Cause: LinkFailure
Severity: critical
44 DN70580522Issue 01A
Troubleshooting Node B
Id:0900d8058022b3ecConfidential
200706 - An error occurred in the nbDatabase
13 200706 - An error occurred in the nbDatabase
13.1 Failure Event Report
13.2 Error DescriptionNode B startup failed because of an error in the nbDatabase.
This may be caused by the following:
• A new database was installed but does not match release and version of the software load.
• A new database was installed but does not match the hardware configuration. • A new hardware equipment was installed but was not configured in the database. • A software error has occurred.
13.3 Troubleshooting (LMT)Depending on the cause due to which the Node B startup failed, perform one of the fol-lowing tasks: • If the new database does not match release and version of the software load:
– Check the Node B database with the mibCheck tool delivered with Node B soft-ware. Proceed according to the “Node B Database Editing Guide”.
– Adapt the database according to the results of this check. Proceed according to the “Node B Database Editing Guide”.
• If the new database does not match the hardware configuration:– Check that the current database version is used (from the RC or on site).
Proceed according to the “Node B Database Editing Guide”.– Upgrade the database if necessary. Use the mibUpgrader tool. Proceed accord-
ing to the “Node B Database Editing Guide”.– Check the Node B database to generate a new database that matches the
hardware configuration. Use the mibCheck or mibCheckWin tool. Proceed according to the “Node B Database Editing Guide”.
– If only little changes are necessary, enter new hardware equipment in database. To edit the Node B’s database, proceed according to the “Node B Database Editing Guide”.
• If new hardware equipment is not configured in the database:– Check the hardware configuration (on site). Use the mibCheck or mibCheckWin
tool. Proceed according to the “Node B Database Editing Guide”.– Enter new hardware equipment in database. To edit the Node B’s database,
proceed according to the “Node B Database Editing Guide”.
Managed Object Class / Hardware Type:
Osu
Event Type: processingErrorAlarm
Probable Cause: SoftwareError
Severity: critical
DN70580522 Issue 01A
45
Troubleshooting Node B 200706 - An error occurred in the nbDatabase
Id:0900d8058022b3ecConfidential
• If the error is not caused by an invalid DB or an unsuitable hardware configuration:Contact the technical assistance center (TAC) to get support in isolating the fault. For suitable preparation save the error symptoms as described in ’Collect Info for Assistance’. Log files need to be analyzed and specific measures must be taken which are out of the operator’s scope.
46 DN70580522Issue 01A
Troubleshooting Node B
Id:0900d8058022b3f4Confidential
200707 - A warning occurred in the nbDatabase
14 200707 - A warning occurred in the nbData-base
14.1 Failure Event Report
14.2 Error DescriptionThere may be an error in the nbDatabase. This warning only occurs during a version upgrade of the database.
There may be the following causes:
1. During version upgrade: There are missing attributes because of using a database from an older version.
2. No version upgrade: The database is defective or a new database was installed but does not match the software version.
14.3 Troubleshooting (LMT)1. There is no action necessary because default values will be used.2. If the new database does not match the software load:
– Check the Node B database with the mibCheck tool delivered with Node B soft-ware. Proceed according to the “Node B Database Editing Guide”.
– Adapt the database according to the results of this check. Proceed according to the “Node B Database Editing Guide”.
g NOTESoftware load and database must base on the same InfoModel which is also the basis for the “Node B Service Terminal Commands” reference manual.
Managed Object Class / Hardware Type:
Osu
Event Type: processingErrorAlarm
Probable Cause: SoftwareError
Severity: warning
DN70580522 Issue 01A
47
Troubleshooting Node B 200905 - VSWR alarm Low
Id:0900d805806e6cd1Confidential
15 200905 - VSWR alarm Low
15.1 Failure Event Report
15.2 Error DescriptionEach antenna port of the DUAMCO/RRH is monitored for the Voltage Standing Wave Ratio (VSWR) of the connected antenna system. Two levels for the antenna return loss can be defined for which an alarm of the appropriate severity will be generated as soon as the relevant threshold (vswrThreshold parameter) is exceeded. The “VSWR alarm Low” is the minor one - which is under consideration here - related with the lower thresh-old and may be received before alarm 200906 - VSWR alarm High. The most likely reason for the VSWR alarms is a defective antenna feeder cable or a damaged antenna.
g NOTEThis alarm does not occur when the TX power falls below the lower power level con-figured for VSWR monitoring.
15.3 Troubleshooting (LMT)To isolate the origin of the high return loss it is necessary to know whether the antenna system is equipped with a TMA/DTMA or not. This is known from the site specific doc-umentation or can be verified by checking the availability via LMT.
Probable causes: • A destroyed antenna due to a stroke of lightning or thunderstorms can trigger this
alarm • Water inleakage or an otherwise damaged feeder cable is the most likely reason • Other alarms related with the TMA, such as “200910 – TMA feeder alarm” or
“200911 – TMA DC alarm” may also be received previously indicating a bro-ken/short-circuit feeder cable or a faulty TMA itself
Managed Object Class / Hardware Type:
Duamco, Rrh
Event Type: equipmentAlarm
Probable Cause: TransmitterAntennaNotAdjusted
Severity: minor
!WARNING – Uncontrolled emission of microwave radiation
Microwave radiation may be emitted uncontrolled during the replacement of antenna cables, antennas, TMAs, DUAMCOs, or RRHs.
To avoid uncontrolled emission of microwave radiation during one of these replacement procedures, apply the following respective task: • When replacing antenna cables, antennas, TMAs, or DUAMCOs, switch off the
relevant breakers which supply the LPAs/CATs involved in the affected antenna branch in order to prevent an uncontrolled emission of microwave radiation.
• For RRHs, switch off the power supply to prevent uncontrolled emission of micro-wave radiation.
48 DN70580522Issue 01A
Troubleshooting Node B
Id:0900d805806e6cd1Confidential
200905 - VSWR alarm Low
For an effective troubleshooting, the actions in the following order should be performed with reference to the relevant manuals:1. Inspect the antenna, the feeder cable and the TMA - if mounted - visually for any
damage caused by lightnings, thunderstorms or other impacts (e.g. bullets).– Replace the defective cable or antenna according to the OEM manual– Replace the defective TMA. Replacement must be done according to the
“Replacing Node B Units” manual, “Tasklist”.2. Check all connectors of the antenna system for correct and tight fit and if loose for
not being corroded.– Tighten loose connectors after removing corrosion or replacing destroyed ones.
3. Measure the antenna feeder cable parameters according to the OEM specification.– Replace the defective cable if minimum requirements are not met according to
the OEM manual.4. If none of the causes above can be identified for the alarm the DUAMCO or RRH is
assumed to be defective.– Replace the DUAMCO or RRH. Replacement must be done according to the
“Replacing Node B Units” manual, “Tasklist”.
DN70580522 Issue 01A
49
Troubleshooting Node B 200906 - VSWR alarm High
Id:0900d805806e5198Confidential
16 200906 - VSWR alarm High
16.1 Failure Event Report
16.2 Error DescriptionEach antenna port of the DUAMCO/RRH is monitored for the Voltage Standing Wave Ratio (VSWR) of the connected antenna system. Two levels for the antenna return loss can be defined for which an alarm of the appropriate severity will be generated as soon as the relevant threshold (vswrThreshold parameter) is exceeded. The 200905 - VSWR alarm Low is the minor one related with the lower threshold and may be received before the “VSWR alarm High” which is under consideration here. The most likely reason for the VSWR alarms is a defective antenna feeder cable or a damaged antenna.
As a consequence, cells or calls could potenitally be lost. Furthermore, the states of all affected managed objects is changed accordingly.
g NOTEThis alarm does not occur when the TX power falls below the lower power level con-figured for VSWR monitoring.
16.3 Troubleshooting (LMT)To isolate the origin of the high return loss it is necessary to know whether the antenna system is equipped with a TMA / DTMA or not. This is known from the site specific doc-umentation or can be verified by checking the availability via LMT.
Probable causes: • A destroyed antenna due to a stroke of lightning or thunderstorms can trigger this
alarm • Water inleakage or an otherwise damaged feeder cable is the most likely reason
Managed Object Class / Hardware Type:
Duamco, Rrh
Event Type: equipmentAlarm
Probable Cause: TransmissionAntennaFailure
Severity: major
50 DN70580522Issue 01A
Troubleshooting Node B
Id:0900d805806e5198Confidential
200906 - VSWR alarm High
• Other alarms related with the TMA, such as “200910 – TMA feeder alarm” or “200911 – TMA DC alarm” may also be received previously indicating a bro-ken/short-circuit feeder cable or a faulty TMA itself
For an effective trouble-shooting the actions in the following order should be performed with reference to the relevant manuals:1. Inspect the antenna, the feeder cable and the TMA - if mounted - visually for any
damage caused by lightnings, thunderstorms or other impacts (e.g. bullets).– Replace the defective cable or antenna according to the OEM manual– Replace the defective TMA. Replacement must be done according to the
“Replacing Node B Units” manual, “Tasklist”.2. Check all connectors of the antenna system for correct and tight fit and if loose for
not being corroded.– Tighten loose connectors after removing corrosion or replacing destroyed ones.
3. Measure the antenna feeder cable parameters according to the OEM specification.– Replace the defective cable if minimum requirements are not met according to
the OEM manual.4. If none of the causes above can be identified for the alarm the DUAMCO or RRH is
assumed to be defective.– Replace the DUAMCO or RRH. Replacement must be done according to the
“Replacing Node B Units” manual, “Tasklist”.
!WARNING – Uncontrolled emission of microwave radiation
Microwave radiation may be emitted uncontrolled during the replacement of antenna cables, antennas, TMAs, DUAMCOs, or RRHs.
To avoid uncontrolled emission of microwave radiation during one of these replacement procedures, apply the following respective task: • When replacing antenna cables, antennas, TMAs, or DUAMCOs, switch off the
relevant breakers which supply the LPAs/CATs involved in the affected antenna branch in order to prevent an uncontrolled emission of microwave radiation.
• For RRHs, switch off the power supply to prevent uncontrolled emission of micro-wave radiation.
DN70580522 Issue 01A
51
Troubleshooting Node B 200907 - RX alarm Low
Id:0900d8058022b40aConfidential
17 200907 - RX alarm Low
17.1 Failure Event Report
17.2 Error DescriptionThis alarm occurred because one branch of an RX amplifier of the reporting LRU has failed. The RX amplifier is still working but degraded in its performance.
Among other scenarios, output of the alarm results from simultaneous occurrence of the following two events: • Misconfiguration (wrong installation) of the Node B
A DTMA for RF = 2100 MHz is installed in a Node B dedicated for use in the 1900 MHz RF band, or vice versa. As a consequence of this misconfiguration, the DTMA breaks.
• Operational state (OST) of the related cell is disabledIf both branches become out of order, the 200908 - RX alarm High will be sent.
17.3 Troubleshooting (LMT)An immediate action is not necessary, but it is recommended to replace the reporting DUAMCO, RRH, DRX, or TMA as soon as possible. Perform the following tasks in the order described:1. First, before replacing the equipment, try to reset the reporting managed object.
Use the TREE View window of the LMT and apply the respective command, depending on the reporting MO:DRX Drx “reset”DUAMCO Duamco “reset”RRH Rrh “reset”TMA Tma “reset”g NOTE
During the reset and the repair action the cell is not available.2. If the alarm persists after the reset, replace the reporting DUAMCO, RRH, DRX, or
TMA. Replacement must be done according to the “Replacing Node B Units” instructions.
Managed Object Class / Hardware Type:
Duamco, Tma, Rrh, Drx
Event Type: equipmentAlarm
Probable Cause: ReceiverFailure
Severity: minor
!DANGER: Uncontrolled emission of microwave radiation.
Damage of health may occur.
To avoid the danger of an uncontrolled emission of microwave radiation, switch off the breakers for the related LPAs/CATs before replacing antenna cables, antennas, RET, or DUAMCO.
52 DN70580522Issue 01A
Troubleshooting Node B
Id:0900d8058022b40aConfidential
200907 - RX alarm Low
g NOTEBefore replacing the DUAMCO, set the DIP-switches on the front side of the DUAMCO in the same configuration as it was on the replaced DUAMCO.
g NOTEAfter replacing the TMA, reset the DUAMCO via LMT or reset button. When resetting the DUAMCO via reset button. press the button for at least eight seconds. Otherwise, the reset will not become effective.Then reset the TMA (via LMT). Use the TREE View window or the Tma “reset” command.
DN70580522 Issue 01A
53
Troubleshooting Node B 200908 - RX alarm High
Id:0900d8058022b410Confidential
18 200908 - RX alarm High
18.1 Failure Event Report
18.2 Error DescriptionThis alarm is output in consequence of various scenarious, depending on the reporting hardware. If this alarm message is sent by the • DUAMCO or direct receiver (DRX) module, both branches of an RX amplifier of the
reporting LRU have failed. • TMA, both branches of an RX amplifier of the reporting LRU have failed.
Furthermore, the MUCO mode in the DUAMCO will switch back to AMCO mode.After the reset, the DUAMCO will be in its original mode according to the DIP-switches on the front.
• RRH, the alarm is output in consequence of one of the following two events– Both branches of the RX-balanced LNA input stage fail.
g This failure cause is applicable for all RRH types.– The root mean square (RMS) of the digital signal has fallen below a specific
threshold for more than 60 seconds [s].Beside an LRU failure, this can also be caused by a general problem on one RX path, such as a cabling problem (DUAMCO – CAT or antenna cabling).g This failure cause is applicable for some RRH types only.
• CAT, the root mean square (RMS) of the digital signal has fallen below a specific threshold for more than 60 seconds [s].The alarm is raised only when some circuit within the RX chain has a malfunction.
Among other scenarios, output of the alarm results from simultaneous occurrence of the following two events: • Misconfiguration (wrong installation) of the Node B
A DTMA for RF = 2100 MHz is installed in a Node B dedicated for use in the 1900 MHz RF band, or vice versa. As a consequence of this misconfiguration, the DTMA breaks.
• Operational state (OST) of the related cell is enabledThere might have been an alarm 200907 - RX alarm Low before.
As a consequence, cells or calls could potentially be lost. Furthermore, the states of all affected managed objects change accordingly.
18.3 Troubleshooting (LMT)g NOTE
Managed Object Class / Hardware Type:
Duamco, Tma, Rrh, Drx, Cat
Event Type: equipmentAlarm
Probable Cause: ReceiverFailure
Severity: major
54 DN70580522Issue 01A
Troubleshooting Node B
Id:0900d8058022b410Confidential
200908 - RX alarm High
During the reset and the repair action the cell is not available.
Take the following measures to clear the fault which led to this alarm:1. If this alarm is reported by a CAT or RRH, check the DUAMCO – CAT or antenna
cabling to rule out any cabling problem.
2. Reset the reporting managed object.Use the TREE View window of the LMT and apply the following action command, depending on the reporting MO:DUAMCO Duamco “Reset”TMA Tma “Reset”RRH Rrh “Reset”DRX Drx “Reset”CAT Cat “Reset”
3. If the alarm persists after the reset, replace the module which corresponds to the reporting managed object.Replacement must be done according to the “Replacing Node B Units” instructions.
g NOTEBefore replacing the DUAMCO, set the DIP-switches on the front side of the DUAMCO in the same configuration as it was on the replaced DUAMCO.
4. After having replaced a defective TMA, take the following measures:4.1 Reset the DUAMCO via LMT or reset button.
When resetting the DUAMCO via LMT, use the TREE View window of the LMT and apply the Duamco “Reset” action command.When resetting the DUAMCO via reset button, press the button for at least eight seconds. Otherwise, the reset will not become effective.
4.2 Then reset the TMA (via LMT).Use the TREE View window of the LMT and apply the Tma “Reset” action command.
!DANGER: Uncontrolled emission of microwave radiation.
Damage of health may occur.
To avoid the danger of an uncontrolled emission of microwave radiation, switch off the breakers for the related LPAs/CATs before checking antenna cables, antennas, RET, or DUAMCO.
!DANGER: Uncontrolled emission of microwave radiation.
Damage of health may occur.
To avoid the danger of an uncontrolled emission of microwave radiation, switch off the breakers for the related LPAs/CATs before replacing antenna cables, antennas, RET, or DUAMCO.
DN70580522 Issue 01A
55
Troubleshooting Node B 200909 - TMA switched off, but not defective
Id:0900d8058022b416Confidential
19 200909 - TMA switched off, but not defective
19.1 Failure Event Report
19.2 Error Description The TMA is switched off, but not defective and the DUAMCO works in AMCO mode. This mode is indicated by the TMA LED which is off. The receiver is degraded in its per-formance. The failure occurs in one of the following situations:
• Most likely this alarm is raised during normal Node B operation if the DIP switch 1 of the corresponding DIP switch group of the DUAMCO is set to OFF position (AMCO mode/TMA off) by accident. The TMA is switched off, but not defective.
• In rare cases, the alarm can also be raised together with another more critical alarm such as 200908 - RX alarm High.
19.3 Troubleshooting (LMT)Check the power supply for the TMA at the associated DUAMCO. Furthermore, verify that the TMA is connected to the DUAMCO and check if the DIP switch 1 of the DUAMCO (TMA ON/OFF) is switched ON.
If the DIP switch 1 was set to the OFF position by accident do the following:
1. Switch the DUAMCO DIP switch 1 to the ON position. The TMA LED should now be on (green), but the alarm still exists at the LMT/RC.
2. Reset the TMA managed object in the TREE View window of the LMT. Apply the Tma “reset” action command to the reporting managed object.
If other critical alarms such as 200908 - RX alarm High are also raised, please refer to the corresponding alarm description. Please note that the DIP switch 1 may be in the ON position in this case.
Managed Object Class / Hardware Type:
Tma
Event Type: equipmentAlarm
Probable Cause: PowerSupplyFailure
Severity: minor
56 DN70580522Issue 01A
Troubleshooting Node B
Id:0900d8058022b41cConfidential
200910 - TMA feeder alarm
20 200910 - TMA feeder alarm
20.1 Failure Event Report
20.2 Error DescriptionThe DUAMCO monitors the 2.176 MHz signaling carrier coming from the TMA. A break-down of this carrier initiates the TMA Feeder Alarm. The amplifier is degraded in its per-formance. The combination of OST/AVS for the addressed TMA and the related localCellE managed object instance changes to disabled/failed and enabled/degraded, respectively.
The “TMA feeder alarm” may be caused by: • A failure in the antenna feeder cable. In this case, the 200905 - VSWR alarm Low /
200906 - VSWR alarm High and uplink/downlink alarms may be additionally active. • A failure in the TMA. • A failure in the power supply, indicated by the 200911 - TMA DC alarm.
If a RET module is installed in the current configuration, the alarm 201004 – RET com-munication error will be output as a consequence of this alarm.
In addition to the above alarm causes, a wrong installation of the Node B may also lead to the “TMA feeder alarm”: whenever a DTMARET (supporting RET) and a DUAMCORT (without RET support) are installed in the same Node B, this alarm is output. As a con-sequence of the wrong configuration, the 201002 – RET feeder alarm may also be output.
For TMA recovery, a reset of the related DUAMCO is required in order to re-establish the communication between the DUAMCO and the TMA. A reset of the TMA managed object is not possible while this failure persists.
20.3 Troubleshooting (LMT)
1. First, reset the related DUAMCO to re-establish the communication between the DUAMCO and the TMA.Use the TREE View window and apply the Duamco “reset” command.
Managed Object Class / Hardware Type:
Tma
Event Type: equipmentAlarm
Probable Cause: ReceiverFailure
Severity: minor
!DANGER: Uncontrolled emission of microwave radiation.
Damage of health may occur.
To avoid the danger of an uncontrolled emission of microwave radiation, switch off the breakers for the related LPAs/CATs before replacing antenna cables, antennas, RET, or DUAMCO.
DN70580522 Issue 01A
57
Troubleshooting Node B 200910 - TMA feeder alarm
Id:0900d8058022b41cConfidential
2. The further procedure depends on the actual problem. Refer to the following list:– If only the “TMA feeder alarm” exists, replace the TMA.
Replacement must be done according to the “Replacing Node B Units” instruc-tions.
– If an additional DC alarm (200911 - TMA DC alarm) is active in the ALARM View window, check the DC/DC converter of the DUAMCO: Unplug the antenna feeder cable and measure the voltage at the antenna port of the DUAMCO. If the voltage is below the defined threshold, the DC/DC converter of the DUAMCO is defective.Replace the DUAMCO. Replacement must be done according to the “Replacing Node B Units” instructions.
– If an additional VSWR alarm (200905 - VSWR alarm Low or 200906 - VSWR alarm High) is active in the ALARM View window, check the antenna feeder cable: If the alarm message is canceled after unplugging the antenna feeder cable, the fault is caused by a short circuit in the antenna feeder cable or an overcharged TMA.Check the antenna feeder cable.
– An additional RET feeder alarm (201002 – RET feeder alarm) normally is a strong indicator for a wrong configuration of the Node B, i.e. installation of a DTMARET (supporting RET) and a DUAMCORT (without RET support).To solve this error, replace the DUAMCORT with a DUAMCORET (supporting RET). Replacement must be done according to the “Replacing Node B Units” instructions.
3. If none of the above reasons could be verified, replace the TMA.Replacement must be done according to the “Replacing Node B Units” instructions.
g NOTEBefore replacing the DUAMCO, set the DIP-switches on the front side of the DUAMCO in the same configuration as it was on the replaced DUAMCO.
g NOTEAfter replacing the TMA, reset the DUAMCO via LMT or reset button. When reset-ting the DUAMCO via reset button, press the button for at least eight (8) seconds. Otherwise the reset will not become effective. Then reset the TMA (via LMT). Use the TREE View window and apply the Tma “reset” command.
58 DN70580522Issue 01A
Troubleshooting Node B
Id:0900d8058022b422Confidential
200911 - TMA DC alarm
21 200911 - TMA DC alarm
21.1 Failure Event Report
21.2 Error DescriptionThe power supply for the TMA is fed via the antenna feeder cable from the DUAMCO/DRX to the TMA. If the supply voltage for the TMA at the antenna port of the DUAMCO/DRX is below the defined threshold (11,3 V), the TMA DC Alarm is initiated.
The TMA DC Alarm may be caused by:
• A failure in the DC/DC converter of the DUAMCO/DRX. • A short circuit in the antenna feeder cable. In this case the alarms 200905 - VSWR
alarm Low or 200906 - VSWR alarm High and uplink/ downlink alarms are addition-ally active.
• The TMA is overcharged. The current consumption of the TMA is too high.
The amplifier is degraded in its performance.
21.3 Troubleshooting (LMT)
1. Unplug the antenna feeder cable and measure the voltage at the antenna port of the DUAMCO/DRX. If the voltage is below the defined threshold, the DC/DC converter of the DUAMCO/DRX is defective. Replace the DUAMCO/DRX. Replacement must be done according to the “Replacing Node B Units” instructions.
2. If the alarm message is cleared after unplugging the antenna feeder cable, the fault is caused by a short circuit in the antenna feeder cable or an overcharged TMA. Check the antenna feeder cable.
3. If none of the above reasons could be verified, replace the TMA. Replacement must be done according to the “Replacing Node B Units” instructions.
g NOTEBefore replacing the DUAMCO/DRX, set the DIP-switches on the front side of the DUAMCO/DRX in the same configuration as it was on the replaced DUAMCO/DRX.
Managed Object Class / Hardware Type:
Duamco, Drx
Event Type: equipmentAlarm
Probable Cause: EquipmentFailure
Severity: minor
!DANGER: Uncontrolled emission of microwave radiation.
Damage of health may occur.
To avoid the danger of an uncontrolled emission of microwave radiation, switch off the breakers for the related LPAs/CATs before replacing antenna cables, antennas, RET, or DUAMCO.
DN70580522 Issue 01A
59
Troubleshooting Node B 200911 - TMA DC alarm
Id:0900d8058022b422Confidential
g NOTEAfter replacing the TMA, reset the DUAMCO/DRX via LMT or reset button. When resetting the DUAMCO/DRX via reset button, press the button for at least eight seconds. Otherwise, the reset will not become effective. Then reset the TMA (via LMT). Use the TREE View window and apply the Tma “reset” command.
60 DN70580522Issue 01A
Troubleshooting Node B
Id:0900d8058022b42aConfidential
200914 - Fan unit failed
22 200914 - Fan unit failed
22.1 Failure Event Report
22.2 Error DescriptionOne of the fan units in the Node B is defective. There might be a failure of components sensitive to heat. Caused by the lack of air circulation, there might occur temperature alarms, reported by the rack/ shelter or the cards.
This alarm message may occur in conjunction with temperature alarms: • 200920 - High temperature of PA • 200921 - Over temperature of PA • 200995 - High Temperature Limit (Ht3) reached • 200996 - Critical Temperature Limit (Ht4) reached
g NOTEIf the reporting Node B is of type NB-441/NB-881/NB-861, the lack of air circulation may be caused by a polluted membrane filter (MEF). Therefore, if the Node B site is located in heavily air-polluted environments combined with special temperature con-ditions, a maintenance of the MEF filters in the outdoor NB-441/NB-881/NB-861 might be necessary.
If the MEFs are polluted, the 201029 - MEF blocked or 201035 - MEF completely blocked alarm is output. Refer to the relevant alarm’s error description and follow the troubleshooting.
g NOTETo avoid toggling of this alarm from the same managed object, i.e. the alarm is raised and ceased alternately, the alarm will only be ceased if the following applies:
After having cleared the cause of this fault, the addressed LRU has not reported the same alarm again for at least 100 seconds.
Otherwise, this alarm will not be ceased but remains active. Troubleshooting tasks for this alarm must be taken.
Managed Object Class / Hardware Type:
Fan
Event Type: environmentalAlarm
Probable Cause: FanFailure
Severity: major
DN70580522 Issue 01A
61
Troubleshooting Node B 200914 - Fan unit failed
Id:0900d8058022b42aConfidential
22.3 Troubleshooting (LMT)g NOTE
If all fan units of the B-shelf are defective, self-disabling of B-shelf cards can occur as a consequence. The Node B handles self-disabled cards as if a fatal board failure, such as an on-board power supply failure, has occurred. In other words, the combination of OST/AVS changes to disabled/not installed and the LED of the self-disabled card is off.
g NOTEThe defective fan unit(s) are recommended to be exchanged within the next 24 hours!
Take the following measures to clear the alarm cause:1. Identify the defective fan unit.
Use either the TREE View window or the ALARM View window of the LMT.2. Replace the fan unit.
Replacement must be done according to the “Replacing Node B Units” manual, “Tasklist”.
!CAUTION: Gyrating rotor!
Damage to health may occur.
When pulling out the fan module, the rotor may still rotate for a few seconds. Wait until the rotor stands still and watch your fingers!
62 DN70580522Issue 01A
Troubleshooting Node B
Id:0900d8058022b255Confidential
200915 - Site input alarm detected
23 200915 - Site input alarm detected
23.1 Failure Event Report
23.2 Error Descriptiong NOTE
Changing the ExtEquipIn managed object’s alarm severity, alarm value, associ-ated string, and probable cause attributes does not affect an existing “200915 - Site input alarm detected” alarm. The modified attributes will take effect for the next occurrence of this alarm.
When modifying the attributes mentioned above, however, only one attribute can be changed simultaneously. In other words, when using the relevant command for setting these attributes, only one single attribute of one single managed object can be set.
A site input alarm was detected.
This alarm is raised if one of the connected site input sensors is active, e.g. water detec-tor, site door open switch, window broken, air condition system defect, etc.
The reported “Probable Cause” and “Severity” in the Failure Event Report depend on the configuration of the related ExtEquipIn managed object in the nbDatabase. • For the severity the value of the attribute label “alarmSeverity” of each object class
ExtEquipIn can be set to minor, major, or critical in the nbDatabase by an equiv-alent string.
• The ExtEquipIn instances ExtEquipIn.4 to ExtEquipIn.12 at the RRH are reserved for reporting alarms related to the power supply units for RRHs (PSRs). These ExtEquipIn instances have to exist in the database in configurations with RRHs.
• Whereas the value of the “probableCause” attribute label is represented by a number which is related to a string defined in the Infomodel, e. g.:4 Battery Breakdown22 Power Supply Failure147 Smoke Detected149 Fuse Failure
• With the AD panel HW, the alarm properties (Probable Cause: PowerSupplyFailure) listed below may be displayed.Source Additional TextExtEquipIn.7 AC/DC Converter - Mains Break Down AlarmExtEquipIn.8 AC/DC Converter - Battery Breakdown AlarmExtEquipIn.9 AC/DC Converter - Battery Charger FaultExtEquipIn.10 AC/DC Converter - DC Output Voltage out of Tolerance
Managed Object Class / Hardware Type:
ExtEquipIn
Event Type: environmentalAlarm
Probable Cause: ExternalEquipmentFailure
Severity: minor, major, critical
DN70580522 Issue 01A
63
Troubleshooting Node B 200915 - Site input alarm detected
Id:0900d8058022b255Confidential
• A broken/defective DCBCTRL may be the cause of this alarm whenever the “200915 - Site input alarm detected” alarm is output four times, showing each of the alarm properties (Probable Cause: PowerSupplyFailure) mentioned below:Source Additional TextExtEquipIn.7 AC/DC Converter - Mains Break Down AlarmExtEquipIn.8 AC/DC Converter - Battery Breakdown AlarmExtEquipIn.9 AC/DC Converter - Battery Charger FaultExtEquipIn.10 AC/DC Converter - DC Output Voltage out of ToleranceDefective DCBCTRL modules have to be replaced.
• If the reporting Node B is of type NB-441 or NB-881, the alarm may also originate from a defect in the over voltage protection of the (optional) OVP box between the Node B and external equipment, such as RRHs.
For explanations of customizing a nbDatabase please refer to the relevant chapter of the “Node B Database Description”.
External equipment input identifier (extEquipInId) and pinning relations to the ACTM (Alarm Collection Terminal Master) can be found in the “Node B Cards/Modules Hardware Description”.
23.3 Troubleshooting (LMT)g If the following alarm properties are displayed after the system was in battery
backup operation, there is no need for further actions:
Source: ExtEquipIn.10 (of ServiceRack.0)
Probable Cause: PowerSupplyFailure
Additional Text: AC/DC Converter – DC Output Voltage out of Tolerance
Before re-charging is finished and battery is full again, it may happen that the alarm oszillates sometimes. When battery is fully charged the alarm is ceased durable.
If this alarm is caused by a defective DCBCTRL module, replace the DCBCTRL. Replacement must be done according to the “Replacing Node B Units” manual.
ChecksOtherwise, confirm whether the indicated root cause for this alarm is plausible: • Is this alarm at the reported ExtEquipIn port probable? Possible alarm causes may
be a broken window, defective air condition system, ingress of moisture, open site door, etc.Inspect the Node B visually. Depending on the result, continue with one of the fol-lowing tasks:– Reset Node B Hardware– On-Site Troubleshooting
• Is this alarm at the reported ExtEquipIn port not probable?Continue with the “Troubleshooting for Improbable Alarm Causes” task.
Troubleshooting for Improbable Alarm CausesA wrong configuration of the database could be the reason for such an alarm. If necces-sary correct the database as follows:1. Upload the database via LMT.
Apply the Osu “uploadDataInitiate”, fileType=database command.2. Find the alarmValue attribute of the extEquipInId of the alarm in question and verify
the setting:
64 DN70580522Issue 01A
Troubleshooting Node B
Id:0900d8058022b255Confidential
200915 - Site input alarm detected
0 low active = closed contact1 high active = open contact
3. Correct the setting if necessary and download the database.Proceed according to the “Node B Database Editing Guide”.
4. Download the corrected database.Apply the Osu “downloadDataInitiate”, fileType=database command.
5. Activate the downloaded database.Apply the Osu “activate” command.
6. If the alarm is still active, continue with the “Reset Node B Hardware” task.
Reset Node B HardwareReset the following hardware of the Node B in the order provided:1. Reset the ACT.
Apply the Act “reset” command.2. Reset the core controller (CC).
Apply the Cc “reset” command.3. If the alarm is still active, continue with the “On-Site Troubleshooting” task.
On-Site Troubleshooting1. Inspect the supervised object for being in false condition and get rid of the conditions
which have caused the alarm. Examples are:– Supervision contacts (for doors, etc.)– Cabling– DIP switch settings– Air condition system
2. Replace suspicious Node B hardware in the following order:2.1 Replace the ACT module. Replacement must be done according to “Replacing
Node B Units”, “Tasklist”.☞ For information about the different ACT types, their locations, functions, and
interfaces, consult the “Node B Cards/Modules Hardware Description”, “ACT”.
2.2 Replace the CC card. Replacement must be done according to “Replacing Node B Units”, “Tasklist”.☞ For information about the different CC types and interfaces, consult the
“Node B Cards/Modules Hardware Description”, “CC”.3. Check and, if neccessary, fix the CAN bus cabling.4. Fix the backplane cabling and the respective terminators.
If the above measures did not help to cease this alarm, contact the technical assistance center (TAC) to get support in isolating the fault. For suitable preparation save the error symptoms as described in “Collect Info for Assistance”. Log files need to be analyzed and specific measures must be taken which are out of the operator’s scope.
DN70580522 Issue 01A
65
Troubleshooting Node B 200916 - Rack Door open
Id:0900d8058022b438Confidential
24 200916 - Rack Door open
24.1 Failure Event Report
24.2 Error DescriptionThe door condition is controlled by a reed switch together with a permanent magnet. This alarm occurs if one of the following doors is open:
• The door of a rack • The door of a single shelter • One or both doors of a double shelter
A damaged or misaligned supervision contact (reed switch - magnet) or a door that is not firmly closed (gap more than 10mm) should also be taken into consideration.
For outdoor shelters it has to be noted that the filter system (MEF = membrane filter) may be by-passed allowing dust to contaminate the equipment in the shelter, resulting in the malfunction.
24.3 Troubleshooting (LMT)Take the following measures to clear the alarm cause:1. Inspect the doors for perfect closing and locking.2. Damaged doors (vandalism) have to be replaced. Shelters must be air tight to
ensure effective air filtering and circulation as well as electromagnetic shielding requirements conformance.
3. If the alarm is active even though all doors are perfectly closed, the supervision contacts (reed switch - magnet) and the cabling should be checked:– Is the door supervision contact connected to the ACT board? For double
shelters the left door contact is connected to the ACTCM at the EMI-Panel, the right door contact is connected to the ACTCB at the DC-Panel. The door contact of single shelters is connected to the ACTCS at the EMI-Panel whereas the door contact of a rack to the ACTCB at the DC-Panel connected is.
– Is the permanent magnet at the top edge of the doors in place? If not, adjust the magnet or fit a new one.
– With the door open place a permanent magnet close to the reed switch at the top edge of the rack/shelter’s opening. Drawing the magnet far and near should activate/deactivate the alarm. If not, the reed switch has to be replaced.
Managed Object Class / Hardware Type:
BaseRack, ServiceRack, Booster
Event Type: environmentalAlarm
Probable Cause: EnclosureDoorOpen
Severity: minor
66 DN70580522Issue 01A
Troubleshooting Node B
Id:0900d8058022b440Confidential
200918 - PA combiner interface fault
25 200918 - PA combiner interface fault
25.1 Failure Event Report
25.2 Error DescriptionAn excessive level of Radio Frequency (RF) reflected power occurred. The cable between the Power Amplifier (PA) and the DUAMCO may be damaged or not con-nected. As a consequence, the PA is switched off.
The PA was put out of service. This leads to a scenario in which cells or calls could potentially be lost. The states of all affected managed objects are then changed accord-ingly.
25.3 Troubleshooting (LMT)1. Check the cable connection between the PA and the DUAMCO:
• For correct attached and tightened connectors (N-type) at PA and DUAMCO • Undamaged cable (visual inspection)☞ Two different lengths of the RG142 cables are used, depending on whether the
PA is located left (80 mm) or right (250 mm) of the DUAMCO.
2. A damaged cable has to be replaced by the right type and length.3. If the error has not ceased yet, the related card has to be replaced. Replacement
must be done according to the “Replacing Node B Units” manual, “Tasklist”.
Managed Object Class / Hardware Type:
Lpa, Booster, Cat
Event Type: equipmentAlarm
Probable Cause: TransmitterFailure
Severity: major
!DANGER: Uncontrolled emission of microwave radiation.
Damage of health may occur.
To prevent uncontrolled emission of microwave radiation, switch off the relevant breakers which supply the LPAs/CATs involved in the affected antenna branch before replacing antenna cables, antennas, cables connected to the output of the power ampli-fier, TMAs, or DUAMCOs.
DN70580522 Issue 01A
67
Troubleshooting Node B 200919 - Failure in the DC supply of PA
Id:0900d8058022b448Confidential
26 200919 - Failure in the DC supply of PA
26.1 Failure Event Report
26.2 Error DescriptionA failure in the internal DC supply of the Power Amplifier (PA) occurred. As a conse-quence, the PA is switched off.
The PA was put out of service. This leads to a scenario in which cells or calls could potentially be lost. The states of all affected managed objects change accordingly.
26.3 Troubleshooting (LMT)At the front of the PA the state of the DC supply is shown by an LED marked “POWER”. This LED can either be ON or OFF, depending on the failure cause inside the PA.
To clear the alarm cause, replace the reporting PA (or external module). Replacement must be done according to the “Repacing Node B Units” manual, “Tasklist”.
Managed Object Class / Hardware Type:
Lpa, Booster, Cat, Rrh, Drx
Event Type: equipmentAlarm
Probable Cause: PowerSupplyFailure
Severity: major
68 DN70580522Issue 01A
Troubleshooting Node B
Id:0900d8058022b450Confidential
200920 - High temperature of PA
27 200920 - High temperature of PA
27.1 Failure Event Report
27.2 Error DescriptionThe temperature of the PA has exceeded the maximum operating temperature speci-fied. This could be caused by an internal problem of the PA or by insufficient cooling of the rack/shelter.
If this alarm is reported by a booster, the 201034 - Booster’s Fan unit failed alarm may be the root cause for the failure reported by this alarm.
An additional rack/shelter temperature alarm (200995 or 200996) or fan alarms (200914) may indicate that the air circulation is decreased. A fan unit could be defective or, especially for outdoor shelters, obstructed air in- or outlets could also reduce the cooling capability.
This alarm message may occur in conjunction with temperature alarms: • 200914 - Fan unit failed • 200995 - High Temperature Limit (Ht3) reached • 200996 - Critical Temperature Limit (Ht4) reached
g NOTEIf the reporting Node B is of type NB-441/NB-881/NB-861, the lack of air circulation may be caused by a polluted membrane filter (MEF). Therefore, if the Node B site is located in heavily air-polluted environments combined with special temperature con-ditions, a maintenance of the MEF filters in the outdoor NB-441/NB-881/NB-861 might be necessary.
If the MEFs are polluted, the 201029 - MEF blocked or 201035 - MEF completely blocked alarm is output. Refer to the relevant alarm’s error description and follow the troubleshooting.
Managed Object Class / Hardware Type:
Lpa, Booster, Cat, Rrh, Drx
Event Type: environmentalAlarm
Probable Cause: HighTemperature
Severity: minor
DN70580522 Issue 01A
69
Troubleshooting Node B 200920 - High temperature of PA
Id:0900d8058022b450Confidential
27.3 Troubleshooting (LMT)Depending on the actual problem, perform one of the following tasks: • In the event that the following preconditions are met, i.e.
– The “200920 – High temperature of PA” alarm is reported by a booster and– The “201034 – Booster’s Fan unit failed” alarm has been output before,refer to the error description of the “201034 – Booster’s Fan unit failed” alarm and follow the troubleshooting accordingly. Reason: the “201034 – Booster’s Fan unit failed” alarm may indicate the root cause for the failure reported by this alarm.
• If this alarm is raised for one single PA only, it is most likely that the PA itself has got a problem. Replace the reporting PA. Replacement must be done according to the “Replacing Node B Units” manual, “Tasklist”.
• If one or more fan alarms or a rack/shelter temperature alarm is reported the addressed fan unit should be checked and possibly replaced. Replacement must be done according to the “Replacing Node B Units” manual, “Tasklist”.
• A rack/shelter temperature alarm leads one to assume that the air circulation is decreased by obstructed air in- or outlets. Check and clean the air in- and outlets according to the section “Cleaning of Air In- and Outlets” in the “Maintaining the Node B” manual.
70 DN70580522Issue 01A
Troubleshooting Node B
Id:0900d8058022b458Confidential
200921 - Over temperature of PA
28 200921 - Over temperature of PA
28.1 Failure Event Report
28.2 Error DescriptionThe PA is overheated and a high temperature alarm (200920 - High temperature of PA) may be preceded. Because the temperature has reached a level that would cause damage, the PA is switched off. This could be caused by an internal problem of the PA or by insufficient cooling capacity of the rack/shelter.
If this alarm is reported by a booster, the 201034 - Booster’s Fan unit failed alarm may be the root cause for the failure reported by this alarm.
An additional rack/shelter temperature alarm (200995 or 200996) or fan alarms (200914) may indicate that the air circulation is decreased. A fan unit could be defective or, especially for outdoor shelters, obstructed air in- or outlets could also reduce the cooling capability.
As a consequence, the PA was put out of service. Cells and/or calls could potentially be lost. The states of all affected managed objects change accordingly.
This alarm message may occur in conjunction with temperature alarms: • 200914 - Fan unit failed • 200995 - High Temperature Limit (Ht3) reached • 200996 - Critical Temperature Limit (Ht4) reached
g NOTEIf the reporting Node B is of type NB-441/NB-881/NB-861, the lack of air circulation may be caused by a polluted membrane filter (MEF). Therefore, if the Node B site is located in heavily air-polluted environments combined with special temperature con-ditions, a maintenance of the MEF filters in the outdoor NB-441/NB-881/NB-861 might be necessary.
If the MEFs are polluted, the 201029 - MEF blocked or 201035 - MEF completely blocked alarm is output. Refer to the relevant alarm’s error description and follow the troubleshooting.
28.3 Troubleshooting (LMT)Depending on the actual problem, perform one of the following tasks: • In the event that the following preconditions are met, i.e.
– The “200921 – Over temperature of PA” alarm is reported by a booster and
Managed Object Class / Hardware Type:
Lpa, Booster, Cat, Rrh, Drx
Event Type: equipmentAlarm
Probable Cause: ExcessiveTransmitterTemperature
Severity: major
DN70580522 Issue 01A
71
Troubleshooting Node B 200921 - Over temperature of PA
Id:0900d8058022b458Confidential
– The “201034 – Booster’s Fan unit failed” alarm has been output before,refer to the error description of the “201034 – Booster’s Fan unit failed” alarm and follow the troubleshooting accordingly. Reason: the “201034 – Booster’s Fan unit failed” alarm may indicate the root cause for the failure reported by this alarm.
• If this alarm is raised for one single PA only, it is most likely that the PA itself has got a problem. Replace the reporting PA. Replacement must be done according to the “Replacing Node B Units” manual, “Tasklist”.
• If one or more fan alarms or a rack/shelter temperature alarm is reported, the addressed fan unit should be checked and possibly replaced. Replacement must be done according to the “Replacing Node B Units” manual, “Tasklist”.
• A rack/shelter temperature alarm leads one to assume that the air circulation is decreased by obstructed air in- or outlets. Check and clean the air in- and outlets according to the section “Cleaning of Air In- and Outlets” in the “Maintaining the Node B” manual.
72 DN70580522Issue 01A
Troubleshooting Node B
Id:0900d8058022b460Confidential
200922 - RF performance not being met due to bad linearization
29 200922 - RF performance not being met due to bad linearization
29.1 Failure Event Report
29.2 Error DescriptionThe PA linearization technics does not work correctly and could result in signal quality not being met. The PA is switched off. The PA was, furthermore, put out of service.
As a consequence, cells or calls could potentially be lost. The states of all affected managed objects change accordingly.
29.3 Troubleshooting (LMT)To clear the alarm cause, the addressed card or external module (such as RRHs) has to be replaced. Replacement must be done according to the “Replacing Node B Units” manual, “Tasklist”.
Managed Object Class / Hardware Type:
Lpa, Booster, Cat, Rrh
Event Type: equipmentAlarm
Probable Cause: SignalQualityEvaluationFault
Severity: major
DN70580522 Issue 01A
73
Troubleshooting Node B 200923 - Internal failure of PA detected
Id:0900d8058022b466Confidential
30 200923 - Internal failure of PA detected
30.1 Failure Event Report
30.2 Error DescriptionA fatal vendor specific hardware or software failure inside the PA was detected and the PA was switched off. Furthermore, the PA was put out of service.
The card should be replaced.
Cells or calls could potentially be lost. The states of all affected managed objects change accordingly.
30.3 Troubleshooting (LMT)1. First, reset the addressed card or external module.
Depending on the reporting managed object, use the TREE View window of the LMT and apply the respective command:Booster Booster “reset”CAT Cat “reset”DRX Drx “reset”LPA Lpa “reset”RRH Rrh “reset”
2. If the fault cannot be cleared by reset, the addressed card/external module has to be replaced. Replacement must be done according to the “Replacing Node B Units” instructions.
Managed Object Class / Hardware Type:
Lpa, Booster, Cat, Rrh, Drx
Event Type: equipmentAlarm
Probable Cause: EquipmentFailure
Severity: major
74 DN70580522Issue 01A
Troubleshooting Node B
Id:0900d8058022b46eConfidential
200924 - Input power level of LPA too high but LPA can still hold its RF specification
31 200924 - Input power level of LPA too high but LPA can still hold its RF specification
31.1 Failure Event Report
31.2 Error DescriptionThe LPA detected an input power level from a TRX card that is above the nominal value. However, the specifications relating to the RF output are still met. There is no imminent danger for the LPA to be damaged.
A further power level increase will result in the error report 200925 - Input power level of PA too high with the higher severity level “major” and a shutdown of the LPA is inevita-ble.
31.3 Troubleshooting (LMT)Take the following measures to clear the alarm cause:1. Check the cables connections.2. Monitor the connected TRX card for a high output level.
g If the output power increases further, the error “200925 – Input power level of PA too high” will occur and the LPA will be switched off.
3. Precautionary, replace the TRX card.Replacement must be done according to the “Replacing Node B Units” manual, “Tasklist”.
Managed Object Class / Hardware Type:
Lpa
Event Type: equipmentAlarm
Probable Cause: ExcessiveTransmitterOutputPower
Severity: minor
DN70580522 Issue 01A
75
Troubleshooting Node B 200925 - Input power level of PA too high
Id:0900d8058022b476Confidential
32 200925 - Input power level of PA too high
32.1 Failure Event Report
32.2 Error DescriptionThe PA detected an input power level that would cause the PA to fail specifications relating to the RF output or damaging the PA. According to the following cases, the input power level may be either analog or digital:
• Case 1: This alarm occurred in an LPA, receiving its input power from a TRX card. Thus, the analog input power level is too high.
• Case 2: This alarm occurred in a CAT/RRH, receiving its input power from DRIC. The following causes may be the root for this failure:– The digital input power level has been too high for a certain period of time. In this
case, an autonomous gain correction was not possible.– Too rapid digital input signal variations could not be processed adequately.– The CAT/RRH itself produces too much power.
To avoid this the PA is switched off. As a consequence, cells or calls could potentially be lost. The states of all affected managed objects change accordingly.
It may be that the error reports 200924 - Input power level of LPA too high but LPA can still hold its RF specification if LPA is affected, or 201018 - The LRU could not process a message from CC if CAT/RRH is affected, were emitted before, being a sign of increasing power level input at the PA.
32.3 Troubleshooting (LMT)Take the following measures to clear the alarm cause:1. First, check the cables connections.2. The related card or external module (such as RRHs) has to be replaced.
Replacement must be done according to the “Replacing Node B Units” manual, “Tasklist”.
Managed Object Class / Hardware Type:
Lpa, Booster, Cat, Rrh
Event Type: equipmentAlarm
Probable Cause: ExcessiveTransmitterOutputPower
Severity: major
76 DN70580522Issue 01A
Troubleshooting Node B
Id:0900d8058022b47cConfidential
200926 - CPU failure of baseband card
33 200926 - CPU failure of baseband card
33.1 Failure Event Report
33.2 Error DescriptionA fatal software or hardware error arose: a boot or watchdog error of a CPU occurred.
After an unsuccessful automatic recovery by means of a reset, the reporting BB card was put out of service.
As a consequence, cells or calls could potentially be lost. The states of all affected managed objects change accordingly.
33.3 Troubleshooting (LMT)1. First, reset the addressed card.
Use the TREE View window of the LMT and, depending on the reporting managed object, apply the respective command:CHC Ch “reset”DRIC Dric “reset”REP Rep “reset”TRX Trx “reset”
2. If the fault cannot be cleared by reset, the addressed card has to be replaced. Replacement must be done according to the “Replacing Node B Units” instructions.
3. Furthermore, contact the technical assistance center (TAC) to get support in isolat-ing the fault. For suitable preparation save the error symptoms as described in “Collect Info for Assistance”. Log files need to be analyzed and specific measures must be taken which are out of the operator’s scope.
Managed Object Class / Hardware Type:
Ch, Rep, Trx, Dric
Event Type: equipmentAlarm
Probable Cause: ProcessorProblem
Severity: major (final), handled according to the Fault Escalation Strategy
DN70580522 Issue 01A
77
Troubleshooting Node B 200927 - Volatile memory failure of baseband card
Id:0900d8058022b482Confidential
34 200927 - Volatile memory failure of baseband card
34.1 Failure Event Report
34.2 Error DescriptionA failure of an SDRAM (synchronous dynamic random access memory) was detected.
After an unsuccessful automatic recovery by means of a reset, the reporting BB card was put out of service.
As a consequence, cells or calls could potentially be lost. The states of all affected managed objects change accordingly.
34.3 Troubleshooting (LMT)1. First, reset the addressed card.
Use the TREE View window of the LMT and, depending on the reporting managed object, apply the respective command:CHC Ch “reset”DRIC Dric “reset”REP Rep “reset”TRX Trx “reset”
2. If the fault cannot be cleared by reset, the addressed card has to be replaced. Replacement must be done according to the “Replacing Node B Units” instructions.
Managed Object Class / Hardware Type:
Ch, Rep, Trx, Dric
Event Type: equipmentAlarm
Probable Cause: EquipmentMalfunction
Severity: major (final), handled according to the Fault Escalation Strategy
78 DN70580522Issue 01A
Troubleshooting Node B
Id:0900d8058022b489Confidential
200928 - Non-volatile memory failure of baseband card
35 200928 - Non-volatile memory failure of baseband card
35.1 Failure Event Report
35.2 Error DescriptionA checksum error was found for a ROM (read only memory).
After an unsuccessful automatic recovery by means of a reset, the reporting BB card was put of service.
As a consequence, cells or calls could potentially be lost. The states of all affected managed objects change accordingly.
35.3 Troubleshooting (LMT)1. First, reset the addressed card.
Use the TREE View window of the LMT and, depending on the reporting managed object, apply the respective command:CHC Ch “reset”DRIC Dric “reset”REP Rep “reset”TRX Trx “reset”
2. If the fault cannot be cleared by reset, the addressed card has to be replaced. Replacement must be done according to the “Replacing Node B Units” instructions.
Managed Object Class / Hardware Type:
Ch, Rep, Trx, Dric
Event Type: processingErrorAlarm
Probable Cause: CorruptData
Severity: major (final), handled according to the Fault Escalation Strategy
DN70580522 Issue 01A
79
Troubleshooting Node B 200929 - DSP failure
Id:0900d8058022b48fConfidential
36 200929 - DSP failure
36.1 Failure Event Report
36.2 Error DescriptionA boot or watchdog error of a UTOPIA relevant DSP (digital signal processor) occurred.
After an unsuccessful automatic recovery by means of a reset, the reporting BB card was put out of service.
As a consequence, cells or calls could potentially be lost. The states of all affected managed objects change accordingly.
36.3 Troubleshooting (LMT)1. First, reset the addressed card.
Use the TREE View window of the LMT and, depending on the reporting managed object, apply the respective command:CHC Ch “reset”DRIC Dric “reset”REP Rep “reset”TRX Trx “reset”
2. If the fault cannot be cleared by reset, the addressed card has to be replaced. Replacement must be done according to the “Replacing Node B Units” instructions.
Managed Object Class / Hardware Type:
Ch, Rep, Trx, Dric
Event Type: equipmentAlarm
Probable Cause: ProcessorProblem
Severity: major (final), handled according to the Fault Escalation Strategy
80 DN70580522Issue 01A
Troubleshooting Node B
Id:0900d8058022b495Confidential
200931 - FPGA failure
37 200931 - FPGA failure
37.1 Failure Event Report
37.2 Error DescriptionA configuration failure of an FPGA (field programmable gate array) was detected.
After an unsuccessful automatic recovery by means of a reset, the reporting BB card was put out of service.
As a consequence, cells or calls could potentially be lost. The states of all affected managed objects change accordingly.
37.3 Troubleshooting (LMT)1. First, reset the addressed card.
Use the TREE View window of the LMT and, depending on the reporting managed object, apply the respective command:CHC Ch “reset”DRIC Dric “reset”REP Rep “reset”TRX Trx “reset”
2. If the fault cannot be cleared by reset, the addressed card has to be replaced. Replacement must be done according to the “Replacing Node B Units” instructions.
Managed Object Class / Hardware Type:
Ch, Rep, Trx, Dric
Event Type: equipmentAlarm
Probable Cause: EquipmentMalfunction
Severity: major (final), handled according to the Fault Escalation Strategy
DN70580522 Issue 01A
81
Troubleshooting Node B 200932 - Control FPGA failure
Id:0900d8058022b49bConfidential
38 200932 - Control FPGA failure
38.1 Failure Event Report
38.2 Error DescriptionA control FPGA (field programmable gate array) failure occurred.
After an unsuccessful automatic recovery by means of a reset, the reporting BB card was put out of service.
As a consequence, cells or calls could potentially be lost. The states of all affected managed objects change accordingly.
38.3 Troubleshooting (LMT)1. First, reset the addressed card.
Use the TREE View window of the LMT and, depending on the reporting managed object, apply the respective command:CHC Ch “reset”DRIC Dric “reset”REP Rep “reset”TRX Trx “reset”
2. If the fault cannot be cleared by reset, the addressed card has to be replaced. Replacement must be done according to the “Replacing Node B Units” instructions.
Managed Object Class / Hardware Type:
Ch, Rep, Trx, Dric
Event Type: equipmentAlarm
Probable Cause: EquipmentMalfunction
Severity: major (final), handled according to the Fault Escalation Strategy
82 DN70580522Issue 01A
Troubleshooting Node B
Id:0900d8058022b4a1Confidential
200933 - External timing signal failure
39 200933 - External timing signal failure
39.1 Failure Event Report
39.2 Error DescriptionFor synchronizing the baseband cards (CH, REP, TRX, DRIC) the Core Controller (CC) sends timing signals via the UTOPIA bus and clock busses. These timing signals derive from the master clock generator of the Core Controller.
• If only one baseband card sends the alarm message: There is a hardware failure in the baseband card. The Node B is degraded in its performance.
• If several baseband cards send the alarm message: There is a failure in the Core Controller. The uplink and downlink connections of the Node B are affected. All affected cells are lost.
After an unsuccessful automatic recovery by means of a reset, the reporting BB card was put out of service.
As a consequence, cells or calls could potentially be lost. The states of all affected managed objects change accordingly.
39.3 Troubleshooting (LMT)1. Contact the technical assistance center (TAC) to get support in isolating the fault.
For suitable preparation save the error symptoms as described in “Collect Info for Assistance”. Log files need to be analyzed and specific measures must be taken which are out of the operator’s scope.
2. Reset the addressed card.Use the TREE View window of the LMT and, depending on the reporting managed object, apply the respective command:CHC Ch “reset”DRIC Dric “reset”REP Rep “reset”TRX Trx “reset”
3. If only one baseband card sends the alarm message and the fault cannot be cleared by reset, replace this baseband card. Replacement must be done according to the “Replacing Node B Units” instructions.
4. If several baseband cards send the alarm message and the fault cannot be cleared by reset, replace the CC. Replacement must be done according to the “Replacing Node B Units” instructions.
Managed Object Class / Hardware Type:
Ch, Rep, Trx, Dric
Event Type: equipmentAlarm
Probable Cause: EquipmentMalfunction
Severity: major (final), handled according to the Fault Escalation Strategy
DN70580522 Issue 01A
83
Troubleshooting Node B 200934 - Failure of the RF part of the TRX
Id:0900d8058022b4a7Confidential
40 200934 - Failure of the RF part of the TRX
40.1 Failure Event Report
40.2 Error DescriptionThere is a hardware failure in the TRX card. Within the TRX card, the radio frequency block (RF) handles the downlink signals. If there is a failure in the RF part, the TRX card does not transmit downlink signals any longer.
After an unsuccessful automatic recovery by means of a reset, the reporting TRX card was put out of service.
As a consequence, cells or calls could potentially be lost. The states of all affected managed objects change accordingly.
40.3 Troubleshooting (LMT)1. First, reset the addressed TRX card.
Use the TREE View window of the LMT and apply the Trx “reset” command to it.2. The TRX card can be blocked locally. The card or carrier can also be blocked from
the LMT.Make sure that the card is not blocked. In other words, confirm that the administra-tive state of the relevant TRX card is set to unlocked.Use either the TREE View window or the RACK View window of the LMT and apply the Trx “Set administrativeState Unlocked” command to the reporting TRX.
3. If the fault cannot be cleared by reset, the addressed card has to be replaced. Replacement must be done according to the “Replacing Node B Units” instructions.
Managed Object Class / Hardware Type:
Trx
Event Type: equipmentAlarm
Probable Cause: EquipmentMalfunction
Severity: major (final), handled according to the Fault Escalation Strategy
84 DN70580522Issue 01A
Troubleshooting Node B
Id:0900d8058022b4adConfidential
200935 - LVDS Failure
41 200935 - LVDS Failure
41.1 Failure Event Report
41.2 Error DescriptionThe LVDS (low voltage differential signal) is an internal connection between the baseband cards. This alarm message occurs if the communication between the baseband cards is interrupted.
After an unsuccessful automatic recovery by means of a reset, the reporting BB card was put out of service.
As a consequence, cells or calls could potentially be lost. The states of all affected managed objects change accordingly.
This alarm message may occur in conjunction with the 200933 - External timing signal failure.
41.3 Troubleshooting (LMT)1. First, reset the addressed card.
Use the TREE View window of the LMT and, depending on the reporting managed object, apply the respective command:CHC Ch “reset”DRIC Dric “reset”REP Rep “reset”TRX Trx “reset”
2. Replace the defective card.Replacement must be done according to the “Replacing Node B Units” instructions.
Managed Object Class / Hardware Type:
Ch, Rep, Trx, Dric
Event Type: communicationsAlarm
Probable Cause: RemoteNodeTransmissionError
Severity: major (final), handled according to the Fault Escalation Strategy
DN70580522 Issue 01A
85
Troubleshooting Node B 200936 - Local bus failure around the CPU
Id:0900d8058022b4b3Confidential
42 200936 - Local bus failure around the CPU
42.1 Failure Event Report
42.2 Error DescriptionLocal bus failure around the CPU.
After an unsuccessful automatic recovery by means of a reset, the reporting BB card was put out of service.
As a consequence, cells or calls could potentially be lost. The states of all affected managed objects change accordingly.
42.3 Troubleshooting (LMT)1. First, reset the addressed card.
Use the TREE View window of the LMT and, depending on the reporting managed object, apply the respective command:CHC Ch “reset”DRIC Dric “reset”REP Rep “reset”TRX Trx “reset”
2. If the fault cannot be cleared by reset, the addressed card has to be replaced. Replacement must be done according to the “Replacing Node B Units” instructions.
Managed Object Class / Hardware Type:
Ch, Rep, Trx, Dric
Event Type: communicationsAlarm
Probable Cause: RemoteNodeTransmissionError
Severity: major (final), handled according to the Fault Escalation Strategy
86 DN70580522Issue 01A
Troubleshooting Node B
Id:0900d8058022b4b9Confidential
200937 - FTP connection failure
43 200937 - FTP connection failure
43.1 Failure Event Report
43.2 Error DescriptionFTP (file transfer protocol) connection between CC card (Core Controller) and BB card (baseband) or CAT (combined amplifier and transceiver) or RRH (remote radio head) could not be established.
After an unsuccessful automatic recovery by means of a reset, the reporting LRU was put out of service.
As a consequence, cells or calls could potentially be lost. The states of all affected managed objects change accordingly.
The error should be reported to customer services. The root of the problem may be a hardware or software error.
43.3 Troubleshooting (LMT)1. First, reset the addressed card or external module (such as RRHs).
Use the TREE View window of the LMT and, depending on the reporting managed object, apply the respective command:CAT Cat “reset”CHC Ch “reset”DRIC Dric “reset”DRX Drx “reset”REP Rep “reset”RRH Rrh “reset”TRX Trx “reset”
2. If the fault cannot be cleared by reset, the addressed card/external module has to be replaced. Replacement must be done according to the “Replacing Node B Units” instructions.
3. Furthermore, contact the technical assistance center (TAC) to get support in isolat-ing the fault. For suitable preparation save the error symptoms as described in “Collect Info for Assistance”. Log files need to be analyzed and specific measures must be taken which are out of the operator’s scope.
Managed Object Class / Hardware Type:
Ch, Rep, Trx, Dric, Cat, Rrh, Drx
Event Type: communicationsAlarm
Probable Cause: TransmissionError
Severity: major (final), handled according to the Fault Escalation Strategy
DN70580522 Issue 01A
87
Troubleshooting Node B 200938 - CRC error during software image check
Id:0900d8058022b4bfConfidential
44 200938 - CRC error during software image check
44.1 Failure Event Report
44.2 Error DescriptionA CRC (cyclic redundancy check) error has been detected while checking the SWI (soft-ware image). This alarm message may occur if a new SW load is activated, which, however, is defective. If no new SW load has been activated, there is an error in the soft-ware.
After an unsuccessful automatic recovery by means of a reset, the reporting BB card was put out of service. As a consequence, cells and/or calls could potentially be lost. The states of all affected managed objects change accordingly.
44.3 Troubleshooting (LMT)Contact the technical assistance center (TAC) to get support in isolating the fault. For suitable preparation save the error symptoms as described in “Collect Info for Assis-tance”. Log files need to be analyzed and specific measures must be taken which are out of the operator’s scope.
Managed Object Class / Hardware Type:
Ch, Rep, Trx, Dric
Event Type: processingErrorAlarm
Probable Cause: FileError
Severity: major (final), handled according to the Fault Escalation Strategy
88 DN70580522Issue 01A
Troubleshooting Node B
Id:0900d8058022b4c5Confidential
200939 - Static configuration file CRC check failed
45 200939 - Static configuration file CRC check failed
45.1 Failure Event Report
45.2 Error DescriptionA CRC (cyclic redundancy check) error has been detected while checking the static con-figuration file. This alarm message may occur if a new SW load is activated, which, however, is defective. If no new SW load has been activated, there is an error in the soft-ware.
After an unsuccessful automatic recovery by means of a reset, the reporting BB card was put out of service. As a consequence, cells or calls could potentially be lost. The states of all affected managed objects change accordingly.
45.3 Troubleshooting (LMT)Contact the technical assistance center (TAC) to get support in isolating the fault. For suitable preparation save the error symptoms as described in “Collect Info for Assis-tance”. Log files need to be analyzed and specific measures must be taken which are out of the operator’s scope.
Managed Object Class / Hardware Type:
Ch, Rep, Trx, Dric
Event Type: processingErrorAlarm
Probable Cause: FileError
Severity: major (final), handled according to the Fault Escalation Strategy
DN70580522 Issue 01A
89
Troubleshooting Node B 200940 - Software activation failed
Id:0900d8058022b4cbConfidential
46 200940 - Software activation failed
46.1 Failure Event Report
46.2 Error DescriptionThe SW version specified in the SW activation command could not be activated.
After an unsuccessful automatic recovery by means of a reset, the reporting BB card was put out of service.
As a consequence, cells or calls could potentially be lost. The states of all affected managed objects change accordingly.
46.3 Troubleshooting (LMT)1. Report this error to the technical assistance center (TAC). For suitable preparation
save the error symptoms as described in “Collect Info for Assistance”. Special actions must be taken and log files need to be analyzed which are out of the opera-tor’s scope.
2. Reset the addressed card.Use the TREE View window of the LMT and, depending on the reporting managed object, apply the respective command:CHC Ch “reset”DRIC Dric “reset”REP Rep “reset”TRX Trx “reset”
3. If the fault cannot be cleared by reset, the addressed card has to be replaced. Replacement must be done according to the “Replacing Node B Units” instructions.
Managed Object Class / Hardware Type:
Ch, Rep, Trx, Dric
Event Type: processingErrorAlarm
Probable Cause: SoftwareProgramAbnormallyTermi-nated
Severity: major (final), handled according to the Fault Escalation Strategy
90 DN70580522Issue 01A
Troubleshooting Node B
Id:0900d8058022b4d1Confidential
200941 - Internal clock failure
47 200941 - Internal clock failure
47.1 Failure Event Report
47.2 Error DescriptionA failure of the internal clock occurred.
After an unsuccessful automatic recovery by means of a reset, the reporting BB card was put out of service.
As a consequence, cells or calls could potentially be lost. The states of all affected managed objects change accordingly.
47.3 Troubleshooting (LMT)1. First, reset the addressed card.
Use the TREE View window of the LMT and, depending on the reporting managed object, apply the respective command:CHC Ch “reset”DRIC Dric “reset”REP Rep “reset”TRX Trx “reset”
2. If the fault cannot be cleared by reset, the addressed card has to be replaced. Replacement must be done according to the “Replacing Node B Units” instructions.
3. Furthermore, contact the technical assistance center (TAC) to get support in isolat-ing the fault. For suitable preparation save the error symptoms as described in “Collect Info for Assistance”. Log files need to be analyzed and specific measures must be taken which are out of the operator’s scope.
Managed Object Class / Hardware Type:
Ch, Rep, Trx, Dric
Event Type: equipmentAlarm
Probable Cause: TimingProblem
Severity: major (final), handled according to the Fault Escalation Strategy
DN70580522 Issue 01A
91
Troubleshooting Node B 200942 - Configuration file inconsistent
Id:0900d8058022b4d7Confidential
48 200942 - Configuration file inconsistent
48.1 Failure Event Report
48.2 Error DescriptionA configuration file contains inconsistent data.
After an unsuccessful automatic recovery by means of a reset, the reporting LRU was put out of service.
As a consequence, cells or calls could potentially be lost. The states of all affected managed objects change accordingly.
48.3 Troubleshooting (LMT)1. Report this error to the technical assistance center (TAC). For suitable preparation
save the error symptoms as described in “Collect Info for Assistance”. Special actions must be taken and log files need to be analyzed which are out of the opera-tor’s scope.
2. Reset the addressed card or external module (such as RRHs).Use the TREE View window of the LMT and, depending on the reporting managed object, apply the respective command:CAT Cat “reset”CHC Ch “reset”DRIC Dric “reset”DRX Drx “reset”REP Rep “reset”RRH Rrh “reset”TRX Trx “reset”
3. If the fault cannot be cleared by reset, the addressed card/external module has to be replaced. Replacement must be done according to the “Replacing Node B Units” instructions.
Managed Object Class / Hardware Type:
Ch, Rep, Trx, Dric, Cat, Rrh, Drx
Event Type: processingErrorAlarm
Probable Cause: FileError
Severity: major (final), handled according to the Fault Escalation Strategy
92 DN70580522Issue 01A
Troubleshooting Node B
Id:0900d8058022b4ddConfidential
200943 - IOR file inconsistent
49 200943 - IOR file inconsistent
49.1 Failure Event Report
49.2 Error DescriptionA fatal software error has occurred. The IOR (interoperable object reference) configura-tion file contains inconsistent data.
After an unsuccessful automatic recovery by means of a reset, the reporting LRU was put out of service.
As a consequence, cells or calls could potentially be lost. The states of all affected managed objects change accordingly.
49.3 Troubleshooting (LMT)1. First, reset the addressed card or external module (such as RRHs).
Use the TREE View window of the LMT and, depending on the reporting managed object, apply the respective command:CAT Cat “reset”CHC Ch “reset”DRIC Dric “reset”DRX Drx “reset”REP Rep “reset”RRH Rrh “reset”TRX Trx “reset”
2. If the fault cannot be cleared by reset, the addressed card/external module has to be replaced. Replacement must be done according to the “Replacing Node B Units” instructions.
3. Report this error to the technical assistance center (TAC). For suitable preparation save the error symptoms as described in “Collect Info for Assistance”. Special actions must be taken and log files need to be analyzed which are out of the opera-tor’s scope.
Managed Object Class / Hardware Type:
Ch, Rep, Trx, Dric, Cat, Rrh, Drx
Event Type: processingErrorAlarm
Probable Cause: FileError
Severity: major (final), handled according to the Fault Escalation Strategy
DN70580522 Issue 01A
93
Troubleshooting Node B 200944 - FTP put failed
Id:0900d8058022b4e3Confidential
50 200944 - FTP put failed
50.1 Failure Event Report
50.2 Error DescriptionA failure occurred while trying to put an FTP (file transfer protocol) file to the CC card (Core Controller). The addressed LRU is reset.
The error should be reported to customer services.
As a consequence of this failure, cells or calls could potentially be lost. The states of all affected managed objects furthermore change accordingly.
50.3 Troubleshooting (LMT)1. First, reset the addressed card.
Use the TREE View window of the LMT and, depending on the reporting managed object, apply the respective command:CHC Ch “reset”DRIC Dric “reset”REP Rep “reset”TRX Trx “reset”
2. If the fault cannot be cleared by reset, the addressed card has to be replaced. Replacement must be done according to the “Replacing Node B Units” instructions.
3. Report this error to the technical assistance center (TAC). For suitable preparation save the error symptoms as described in “Collect Info for Assistance”. Special actions must be taken and log files need to be analyzed which are out of the opera-tor’s scope.
Managed Object Class / Hardware Type:
Ch, Rep, Trx, Dric
Event Type: communicationsAlarm
Probable Cause: TransmissionError
Severity: warning (final), handled according to the Fault Escalation Strategy
94 DN70580522Issue 01A
Troubleshooting Node B
Id:0900d8058022b4e9Confidential
200945 - FTP manage failure
51 200945 - FTP manage failure
51.1 Failure Event Report
51.2 Error DescriptionA failure occurred in managing the RAM (random access memory) disc via FTP. The addressed LRU is reset.
The error should be reported to customer services.
As a consequence of this failure, cells or calls could potentially be lost. The states of all affected managed objects change accordingly.
51.3 Troubleshooting (LMT)1. First, reset the addressed card.
Use the TREE View window of the LMT and, depending on the reporting managed object, apply the respective command:CHC Ch “reset”DRIC Dric “reset”REP Rep “reset”TRX Trx “reset”
2. If the fault cannot be cleared by reset, the addressed card has to be replaced. Replacement must be done according to the “Replacing Node B Units” instructions.
3. Report this error to the technical assistance center (TAC). For suitable preparation save the error symptoms as described in “Collect Info for Assistance”. Special actions must be taken and log files need to be analyzed which are out of the opera-tor’s scope.
Managed Object Class / Hardware Type:
Ch, Rep, Trx, Dric
Event Type: processingErrorAlarm
Probable Cause: CorruptData
Severity: warning (final), handled according to the Fault Escalation Strategy
DN70580522 Issue 01A
95
Troubleshooting Node B 200946 - Still alive supervision failure
Id:0900d8058022b4efConfidential
52 200946 - Still alive supervision failure
52.1 Failure Event Report
52.2 Error DescriptionA still alive supervision failure occurred. It is possible that a hardware or software error is the root of the problem.
After an unsuccessful automatic recovery by means of a reset, the reporting LRU was put out of service.
As a consequence, cells or calls could potentially be lost. The states of all affected managed objects change accordingly.
52.3 Troubleshooting (LMT)1. First, reset the addressed card or external module (such as RRHs).
Use the TREE View window of the LMT and, depending on the reporting managed object, apply the respective command:CAT Cat “reset”CHC Ch “reset”DRIC Dric “reset”DRX Drx “reset”REP Rep “reset”RRH Rrh “reset”TRX Trx “reset”
2. If the fault cannot be cleared by reset, the addressed card/external module has to be replaced. Replacement must be done according to the “Replacing Node B Units” instructions.
3. Report this error to the technical assistance center (TAC). For suitable preparation save the error symptoms as described in “Collect Info for Assistance”. Special actions must be taken and log files need to be analyzed which are out of the opera-tor’s scope.
Managed Object Class / Hardware Type:
Ch, Rep, Trx, Dric, Cat, Rrh, Drx
Event Type: equipmentAlarm
Probable Cause: EquipmentMalfunction
Severity: major (final), handled according to the Fault Escalation Strategy
96 DN70580522Issue 01A
Troubleshooting Node B
Id:0900d8058022b4f5Confidential
200947 - Failure in the DC supply of DUAMCO
53 200947 - Failure in the DC supply of DUAMCO
53.1 Failure Event Report
53.2 Error DescriptionThe DUAMCO is switched off. As a consequence, the DUAMCO was put out of service.
Furthermore, cells or calls could potentially be lost. The states of all affected managed objects change accordingly.
53.3 Troubleshooting (LMT)1. First, reset the addressed card.
Use the TREE View window of the LMT and apply the Duamco “reset” command to the addressed card.
2. If the fault cannot be cleared by reset, the addressed card has to be replaced.Replacement must be done according to the “Replacing Node B Units” instructions.
g NOTEBefore replacing the DUAMCO, set the DIP-switches on the front side of the DUAMCO in the same configuration as it was on the replaced DUAMCO.
Managed Object Class / Hardware Type:
Duamco
Event Type: equipmentAlarm
Probable Cause: PowerSupplyFailure
Severity: major
!DANGER: Uncontrolled emission of microwave radiation.
Damage of health may occur.
To prevent uncontrolled emission of microwave radiation, switch off the relevant breakers which supply the LPAs/CATs involved in the affected antenna branch before replacing antenna cables, antennas, TMAs, or DUAMCOs.
DN70580522 Issue 01A
97
Troubleshooting Node B 200948 - CORBA communication failed
Id:0900d8058022b4fbConfidential
54 200948 - CORBA communication failed
54.1 Failure Event Report
54.2 Error DescriptionThis alarm message is output due to the following fatal error: a CORBA (common object request broker architecture) communication failure between CC and the reporting LRU occurred. It is possible that a hardware or a software error is the root of the problem.
After an unsuccessful automatic recovery by means of a reset, the reporting LRU was put out of service.
As a consequence, cells or calls could potentially be lost. The states of all affected managed objects change accordingly.
54.3 Troubleshooting (LMT)1. First, reset the addressed card or external module (such as RRHs).
Use the TREE View window of the LMT and, depending on the reporting managed object, apply the respective command:CAT Cat “reset”CHC Ch “reset”DRIC Dric “reset”REP Rep “reset”RRH Rrh “reset”TRX Trx “reset”
2. If the fault cannot be cleared by reset, the addressed card/external module has to be replaced. Replacement must be done according to the “Replacing Node B Units” instructions.
3. If the fault cannot be cleared by reset, contact the technical assistance center (TAC) to get support in isolating the fault. For suitable preparation save the error symptoms as described in “Collect Info for Assistance”. Log files need to be analyzed and specific measures must be taken which are out of the operator’s scope.
Managed Object Class / Hardware Type:
Ch, Rep, Trx, Dric, Cat, Rrh
Event Type: communicationsAlarm
Probable Cause: TransmissionError
Severity: major (final), handled according to the Fault Escalation Strategy
98 DN70580522Issue 01A
Troubleshooting Node B
Id:0900d8058022b501Confidential
200949 - Internal CORBA call failed
55 200949 - Internal CORBA call failed
55.1 Failure Event Report
55.2 Error DescriptionA fatal software error has occurred! This is a recoverable error situation caused by a potentially serious software fault which should be reported to customer services! The recovery will result in a complete reset of the Node B. Due to the reset, all services will be interrupted.
This means:
• All cells will be lost. • The connection between the Node B and the RNC will be lost. • Uplink or downlink errors will be reported by other Node Bs if they are connected to
the resetting Node B.
All connections to the management system will also be interrupted during this reset period. Once the reset is completed, normal operational service should be resumed i.e. the cells are built up again, connection with the RNC will be re-established, and any cross connections will be built up again. Any calls that were in operation before the reset are lost.
55.3 Troubleshooting (LMT)Contact the technical assistance center (TAC) to get support in isolating the fault. For suitable preparation save the error symptoms as described in “Collect Info for Assis-tance”. Log files need to be analyzed and specific measures must be taken which are out of the operator’s scope.
Managed Object Class / Hardware Type:
Cc
Event Type: communicationsAlarm
Probable Cause: TransmissionError
Severity: warning
DN70580522 Issue 01A
99
Troubleshooting Node B 200950 - Timeout for request or modification
Id:0900d8058022b509Confidential
56 200950 - Timeout for request or modification
56.1 Failure Event Report
56.2 Error DescriptionA fatal hardware error has occurred. The card did not send an expected response or notification.
After an unsuccessful automatic recovery by means of a reset, the reporting LRU was put out of service.
As a consequence, cells or calls could potentially be lost. The states of all affected managed objects change accordingly.
56.3 Troubleshooting (LMT)Take the following measures to clear the alarm cause:1. First, reset the addressed card.2. If the fault cannot be cleared by reset, the addressed card has to be replaced.
Replacement must be done according to the “Replacing Node B Units” manual, “Tasklist”.
3. Contact the technical assistance center (TAC) to get support in isolating the fault. For suitable preparation save the error symptoms as described in “Collect Info for Assistance”. Log files need to be analyzed and specific measures must be taken which are out of the operator’s scope.
Managed Object Class / Hardware Type:
*
Event Type: processingErrorAlarm
Probable Cause: TimeoutExpired
Severity: major (final), handled according to the Fault Escalation Strategy
100 DN70580522Issue 01A
Troubleshooting Node B
Id:0900d8058022b511Confidential
200951 - Status notification undefined
57 200951 - Status notification undefined
57.1 Failure Event Report
57.2 Error DescriptionA fatal hardware error has occurred. The card sends an unknown status notification.
After an unsuccessful automatic recovery by means of a reset, the reporting LRU was put out of service.
As a consequence, cells or calls could potentially be lost. The states of all affected managed objects change accordingly.
57.3 Troubleshooting (LMT)1. First, reset the addressed card.2. If the fault cannot be cleared by reset, contact the technical assistance center (TAC)
to get support in isolating the fault. For suitable preparation save the error symptoms as described in ’Collect Info for Assistance’. Log files need to be analyzed and specific measures must be taken which are out of the operator’s scope.
Managed Object Class / Hardware Type:
*
Event Type: processingErrorAlarm
Probable Cause: CorruptData
Severity: major (final), handled according to the Fault Escalation Strategy
DN70580522 Issue 01A
101
Troubleshooting Node B 200952 - Maximum number of resets exceeded
Id:0900d8058022b519Confidential
58 200952 - Maximum number of resets exceeded
58.1 Failure Event Report
58.2 Error DescriptionA fatal hardware error or software error occurred. The card was not able to start up com-pletely even after performing several numbers of resets.
The reporting LRU was put out of service.
As a consequence, cells or calls could potentially be lost. The states of all affected managed objects change accordingly.
58.3 Troubleshooting (LMT)Take the following actions to clear the alarm condition:1. Since the fault could not be cleared by the numerous resets, the addressed card has
to be replaced.Replacement must be done according to the “Replacing Node B Units” manual, “Tasklist”.
2. If the fault cannot be cleared by card replacement, contact the technical assistance center (TAC) to get support in isolating the fault. For suitable preparation save the error symptoms as described in “Collect Info for Assistance”. Log files need to be analyzed and specific measures must be taken which are out of the operator’s scope.
Managed Object Class / Hardware Type:
*
Event Type: equipmentAlarm
Probable Cause: EquipmentMalfunction
Severity: major
102 DN70580522Issue 01A
Troubleshooting Node B
Id:0900d8058022b521Confidential
200953 - CAN bus off
59 200953 - CAN bus off
59.1 Failure Event Report
59.2 Error DescriptionThere is an error detected in the physical CAN communication layer. Service may thus be affected.
This alarm message may occur in conjunction with other CAN-related alarms: • 200954 - No message response on CAN • 200955 - Mount supervision failure • 200956 - Watch dog timer expired • 200957 - Internal CAN processing failure
59.3 Troubleshooting (LMT)Take the following measures to clear the alarm cause:1. First, reset the addressed card.2. If the fault cannot be cleared by reset, the addressed card has to be replaced.
Replacement must be done according to the “Replacing Node B Units” manual, “Tasklist”.
3. If the card replacement did not clear the fault, contact the technical assistance center (TAC) to get support in isolating the fault. For suitable preparation save the error symptoms as described in “Collect Info for Assistance”. Log files need to be analyzed and specific measures must be taken which are out of the operator’s scope.
Managed Object Class / Hardware Type:
*
Event Type: equipmentAlarm
Probable Cause: ProcessorProblem
Severity: warning
DN70580522 Issue 01A
103
Troubleshooting Node B 200954 - No message response on CAN
Id:0900d8058022b529Confidential
60 200954 - No message response on CAN
60.1 Failure Event Report
60.2 Error DescriptionThe watchdog timer on the CAN bus is expired. An object on the affected CAN bus therefore performed a reset.
After an unsuccessful automatic recovery by means of a reset, the reporting LRU was put out of service.
As a consequence, cells or calls could potentially be lost. The states of all affected managed objects change accordingly.
This alarm message may occur in conjunction with other CAN-related alarms: • 200953 - CAN bus off • 200955 - Mount supervision failure • 200956 - Watch dog timer expired • 200957 - Internal CAN processing failure
60.3 Troubleshooting (LMT)Take the following measures to clear the alarm cause:1. First, reset the addressed card.2. If the fault cannot be cleared by reset, the addressed card has to be replaced.
Replacement must be done according to the “Replacing Node B Units” manual, “Tasklist”.
3. If the card replacement did not clear the fault, contact the technical assistance center (TAC) to get support in isolating the fault. For suitable preparation save the error symptoms as described in “Collect Info for Assistance”. Log files need to be analyzed and specific measures must be taken which are out of the operator’s scope.
Managed Object Class / Hardware Type:
*
Event Type: processingErrorAlarm
Probable Cause: TimeoutExpired
Severity: major (final), handled according to the Fault Escalation Strategy
104 DN70580522Issue 01A
Troubleshooting Node B
Id:0900d8058022b531Confidential
200955 - Mount supervision failure
61 200955 - Mount supervision failure
61.1 Failure Event Report
61.2 Error DescriptionA CAN object performed a reset caused by expiration of the mount supervision timer.
After an unsuccessful automatic recovery by means of a reset, the reporting LRU was put out of service.
As a consequence, cells or calls could potentially be lost. The states of all affected managed objects change accordingly.
This alarm message may occur in conjunction with other CAN-related alarms: • 200953 - CAN bus off • 200954 - No message response on CAN • 200956 - Watch dog timer expired • 200957 - Internal CAN processing failure
61.3 Troubleshooting (LMT)Take the following measures to clear the alarm cause:1. First, reset the addressed card.2. If the fault cannot be cleared by reset, the addressed card has to be replaced.
Replacement must be done according to the “Replacing Node B Units” manual, “Tasklist”.
3. If the card replacement did not clear the fault, contact the technical assistance center (TAC) to get support in isolating the fault. For suitable preparation save the error symptoms as described in “Collect Info for Assistance”. Log files need to be analyzed and specific measures must be taken which are out of the operator’s scope.
Managed Object Class / Hardware Type:
*
Event Type: processingErrorAlarm
Probable Cause: TimeoutExpired
Severity: major (final), handled according to the Fault Escalation Strategy
DN70580522 Issue 01A
105
Troubleshooting Node B 200956 - Watch dog timer expired
Id:0900d8058022b539Confidential
62 200956 - Watch dog timer expired
62.1 Failure Event Report
62.2 Error DescriptionThe watch dog timer on CAN bus expired.
If the reporting managed object is a CAT (combined amplifier and transceiver) or a RRH (remote radio head), the following applies: The CAT’s/RRH’s CPU (central processing unit) watchdog detected a CPU failure.
After an unsuccessful automatic recovery by means of a reset, the reporting LRU was put out of service.
As a consequence, cells or calls could potentially be lost. The states of all affected managed objects change accordingly.
This alarm message may occur in conjunction with other CAN-related alarms: • 200953 - CAN bus off • 200954 - No message response on CAN • 200955 - Mount supervision failure • 200957 - Internal CAN processing failure
62.3 Troubleshooting (LMT)Take the following measures to clear the alarm cause:1. First, reset the addressed card.2. If the fault cannot be cleared by reset, the addressed card has to be replaced.
Replacement must be done according to the “Replacing Node B Units” manual, “Tasklist”.
3. If the card replacement did not clear the fault, contact the technical assistance center (TAC) to get support in isolating the fault. For suitable preparation save the error symptoms as described in “Collect Info for Assistance”. Log files need to be analyzed and specific measures must be taken which are out of the operator’s scope.
Managed Object Class / Hardware Type:
*
Event Type: processingErrorAlarm
Probable Cause: WatchDogTimerExpired
Severity: major (final), handled according to the Fault Escalation Strategy
106 DN70580522Issue 01A
Troubleshooting Node B
Id:0900d8058022b541Confidential
200957 - Internal CAN processing failure
63 200957 - Internal CAN processing failure
63.1 Failure Event Report
63.2 Error DescriptionA CAN object performed a reset caused by an internal processing failure.
After an unsuccessful automatic recovery by means of a reset, the reporting LRU was put out of service.
As a consequence, cells or calls could potentially be lost. The states of all affected managed objects change accordingly.
This alarm message may occur in conjunction with other CAN-related alarms: • 200953 - CAN bus off • 200954 - No message response on CAN • 200955 - Mount supervision failure • 200956 - Watch dog timer expired
63.3 Troubleshooting (LMT)Take the following measures to clear the alarm cause:1. First, reset the addressed card.2. If the fault cannot be cleared by reset, the addressed card has to be replaced.
Replacement must be done according to the “Replacing Node B Units” manual, “Tasklist”.
3. If the card replacement did not clear the fault, contact the technical assistance center (TAC) to get support in isolating the fault. For suitable preparation save the error symptoms as described in “Collect Info for Assistance”. Log files need to be analyzed and specific measures must be taken which are out of the operator’s scope.
Managed Object Class / Hardware Type:
*
Event Type: equipmentAlarm
Probable Cause: EquipmentMalfunction
Severity: major (final), handled according to the Fault Escalation Strategy
DN70580522 Issue 01A
107
Troubleshooting Node B 200958 - Timer for the reset supervision expired
Id:0900d8058022b549Confidential
64 200958 - Timer for the reset supervision expired
64.1 Failure Event Report
64.2 Error DescriptionThe timer for the reset supervision has been expired.
After an unsuccessful automatic recovery by means of a reset, the reporting LRU was put out of service.
As a consequence, cells or calls could potentially be lost. The states of all affected managed objects change accordingly.
64.3 Troubleshooting (LMT)1. First, reset the addressed card.2. If the fault cannot be cleared by reset, contact the technical assistance center (TAC)
to get support in isolating the fault. For suitable preparation save the error symptoms as described in ’Collect Info for Assistance’. Log files need to be analyzed and specific measures must be taken which are out of the operator’s scope.
Managed Object Class / Hardware Type:
*
Event Type: equipmentAlarm
Probable Cause: TimingProblem
Severity: major (final), handled according to the Fault Escalation Strategy
108 DN70580522Issue 01A
Troubleshooting Node B
Id:0900d8058022b54fConfidential
200959 - Missing response from baseband card
65 200959 - Missing response from baseband card
65.1 Failure Event Report
65.2 Error DescriptionThe following fatal error has occurred: NBAP (Node B application part) has detected a missing response from a baseband card. It is possible that a hardware or software error is the root of the problem. The problem may be located either in the reporting baseband (BB) card or in the core controller (CC).
After an unsuccessful automatic recovery by means of a reset, the reporting BB card was put out of service.
As a consequence, cells or calls could potentially be lost. The states of all affected managed objects change accordingly.
The error should be reported to customer service.
65.3 Troubleshooting (LMT)1. First, reset the addressed card.
Use the TREE View window of the LMT and, depending on the reporting baseband card, apply the following command:CHC (Ch) Ch “reset”REP (Rep) Rep “reset”TRX (Trx) Trx “reset”DRIC (Dric) Dric “reset”
2. If the fault cannot be cleared by reset, replace defective cards:2.1 Replace the addressed baseband card.2.2 Even though the alarm is reported by a baseband card, the core controller may
also be the root cause of the detected problem. Therefore, replace the core con-troller.
For either card, replacement must be done according to the “Replacing Node B Units” instructions.
3. If the card replacement did not clear the fault, either, contact the technical assis-tance center (TAC) to get support in isolating the fault. For suitable preparation save the error symptoms as described in “Collect Info for Assistance”. Log files need to be analyzed and specific measures must be taken which are out of the operator’s scope.
Managed Object Class / Hardware Type:
Ch, Rep, Trx, Dric
Event Type: processingErrorAlarm
Probable Cause: TimeoutExpired
Severity: major (final), handled according to the Fault Escalation Strategy
DN70580522 Issue 01A
109
Troubleshooting Node B 200960 - Invalid response from baseband card
Id:0900d8058022b555Confidential
66 200960 - Invalid response from baseband card
66.1 Failure Event Report
66.2 Error DescriptionThe following fatal software error has occurred: NBAP (Node B application part) has detected an invalid response from a baseband card. It is possible that a hardware or software error is the root of the problem.
After an unsuccessful automatic recovery by means of a reset, the reporting BB card was put out of service.
As a consequence, cells or calls could potentially be lost. The states of all affected managed objects change accordingly.
The error should be reported to customer service.
66.3 Troubleshooting (LMT)1. First, reset the addressed card.
Use the TREE View window of the LMT and, depending on the reporting managed object, apply the respective command:CHC Ch “reset”DRIC Dric “reset”REP Rep “reset”TRX Trx “reset”
2. If the fault cannot be cleared by reset, the addressed card has to be replaced. Replacement must be done according to the “Replacing Node B Units” instructions.
3. If the card replacement did not clear the fault, contact the technical assistance center (TAC) to get support in isolating the fault. For suitable preparation save the error symptoms as described in “Collect Info for Assistance”. Log files need to be analyzed and specific measures must be taken which are out of the operator’s scope.
Managed Object Class / Hardware Type:
Ch, Rep, Trx, Dric
Event Type: communicationsAlarm
Probable Cause: InvalidMessageReceived
Severity: major (final), handled according to the Fault Escalation Strategy
110 DN70580522Issue 01A
Troubleshooting Node B
Id:0900d8058022b55dConfidential
200961 - Firmware download failure
67 200961 - Firmware download failure
67.1 Failure Event Report
67.2 Error DescriptionA fatal hardware error was detected while downloading the FW (firmware) or no FW is available at all at the card.
The reporting LRU was put out of service.
As a consequence, cells or calls could potentially be lost. The states of all affected managed objects change accordingly.
67.3 Troubleshooting (LMT)Take the following measures to clear the alarm cause:1. First, reset the addressed card.2. If the fault cannot be cleared by reset, the addressed card has to be replaced.
Replacement must be done according to the “Replacing Node B Units” manual, “Tasklist”.
3. If the card replacement did not clear the fault, contact the technical assistance center (TAC) to get support in isolating the fault. For suitable preparation save the error symptoms as described in “Collect Info for Assistance”. Log files need to be analyzed and specific measures must be taken which are out of the operator’s scope.
Managed Object Class / Hardware Type:
*
Event Type: processingErrorAlarm
Probable Cause: SoftwareDownloadFailure
Severity: major
DN70580522 Issue 01A
111
Troubleshooting Node B 200980 - Invalid MO
Id:0900d8058022b565Confidential
68 200980 - Invalid MO
68.1 Failure Event Report
68.2 Error DescriptionAn object was accessed at the CAN bus which does not exist or which is not mounted.
There may be following causes:
• The Node B database is defective. A new database was installed but does not match the hardware configuration.
• The hardware configuration is invalid. A new hardware equipment was installed but does not match the database.
• A software error has occurred.
68.3 Troubleshooting (LMT)Perform the following tasks in the given order to solve this alarm:1. Check if the Node B works with the newest version of the database. Use the
mibCheck or mibCheckWin tool delivered with the Node B’s software. Proceed according to the “Node B Database Editing Guide”.
2. If necessary, change the running database. Edit the database according to the “Node B Database Editing Guide”.
3. Otherwise, if the database was not defective, check the hardware configuration.Check the entry in the database and check the addressed MO on site. There might have been a change of the MO type on site or in the configuration, which was not edited in the database.
4. If the error is not caused by an invalid database or an unsuitable hardware configu-ration, contact the technical assistance center (TAC) to get support in isolating the fault. For suitable preparation save the error symptoms as described in “Collect Info for Assistance”. Log files need to be analyzed and specific measures must be taken which are out of the operator’s scope.
Managed Object Class / Hardware Type:
*
Event Type: processingErrorAlarm
Probable Cause: DatabaseInconsistency
Perceived severity: warning
112 DN70580522Issue 01A
Troubleshooting Node B
Id:0900d8058022b56dConfidential
200981 - MO not mounted
69 200981 - MO not mounted
69.1 Failure Event Report
69.2 Error DescriptionThe specified MO is not mounted.
69.3 Troubleshooting (LMT)Check if the addressed card is equipped. If not, insert a card of the required type, HW and FW state. Proceed according to the installation manual (IMN) of the reporting Node B type: • For NB-440 or NB-880, refer to “Installing NB-440/NB-880”. • For NB-441 or NB-881, refer to “Installing NB-441/NB-881”. • For NB-420 or NB-860, refer to “Installing NB-420/NB-860”. • For NB-861, refer to “Installing NB-861”. • For NB-341, refer to “Installing NB-341”. • For Radio Server Slider Unit RSSU-380, refer to “Installing RSSU-380”. • For Radio Server RS-381, refer to “Installing RS-381”. • For Radio Server RS-880, refer to “Installing RS-880”.
Managed Object Class / Hardware Type:
*
Event Type: communicationsAlarm
Probable Cause: Unavailable
Severity: warning
DN70580522 Issue 01A
113
Troubleshooting Node B 200982 - Invalid command
Id:0900d8058022b575Confidential
70 200982 - Invalid command
70.1 Failure Event Report
70.2 Error DescriptionA CAN command is invalid.
This alarm may be caused by one of the following: • The Node B database is defective. A new database was installed but does not
match the hardware configuration. • The hardware configuration is invalid. A new hardware equipment was installed but
does not match the database. • A software error has occurred.
70.3 Troubleshooting (LMT)Perform the following tasks in the given order to solve this alarm:1. Check the Node B database and software version. Use the mibCheck or mibCheck-
Win tool delivered with the Node B’s software. Proceed according to the “Node B Database Editing Guide”.
2. If necessary, change the running database. Edit the database according to the “Node B Database Editing Guide”.
3. Otherwise, if the database was not defective, check the hardware configuration.Check the entry in the database and check the addressed MO on site. There might have been a change of the MO type on site or in the configuration, which was not edited in the database.
4. If the error is not caused by an invalid database or an unsuitable hardware configu-ration: Contact the technical assistance center (TAC) to get support in isolating the fault. For suitable preparation save the error symptoms as described in “Collect Info for Assistance”. Log files need to be analyzed and specific measures must be taken which are out of the operator’s scope.
Managed Object Class / Hardware Type:
*
Event Type: processingErrorAlarm
Probable Cause: CorruptData
Severity: warning
114 DN70580522Issue 01A
Troubleshooting Node B
Id:0900d8058022b57dConfidential
200983 - Invalid parameter in command
71 200983 - Invalid parameter in command
71.1 Failure Event Report
71.2 Error DescriptionA CAN command contains an invalid parameter.
This alarm may be caused by one of the following: • The Node B database is defective. A new database was installed but does not
match the hardware configuration. • The hardware configuration is invalid. A new hardware equipment was installed but
does not match the database. • A software error has occurred.
71.3 Troubleshooting (LMT)Perform the following tasks in the given order to solve this alarm:1. Check the Node B database and software version. Use the mibCheck or mibCheck-
Win tool delivered with the Node B’s software. Proceed according to the “Node B Database Editing Guide”.
2. If necessary, change the running database. Edit the database according to the “Node B Database Editing Guide”.
3. Otherwise, if the database was not defective, check the hardware configuration.Check the entry in the database and check the addressed MO on site. There might have been a change of the MO type on site or in the configuration, which was not edited in the database.
4. If the error is not caused by an invalid database or an unsuitable hardware configu-ration: Contact the technical assistance center (TAC) to get support in isolating the fault. For suitable preparation save the error symptoms as described in “Collect Info for Assistance”. Log files need to be analyzed and specific measures must be taken which are out of the operator’s scope.
Managed Object Class / Hardware Type:
*
Event Type: processingErrorAlarm
Probable Cause: InvalidParameter
Severity: warning
DN70580522 Issue 01A
115
Troubleshooting Node B 200984 - Firmware download access file error
Id:0900d8058022b585Confidential
72 200984 - Firmware download access file error
72.1 Failure Event Report
72.2 Error DescriptionFW (firmware) download access file error. The access to the card firmware is not possi-ble. Probably providing a wrong software causes the problem.
72.3 Troubleshooting (LMT)Take the following measures to clear the alarm cause:1. Contact the technical assistance center (TAC) to get support in isolating the fault.
For suitable preparation save the error symptoms as described in “Collect Info for Assistance”. Log files need to be analyzed and specific measures must be taken which are out of the operator’s scope.
2. Choose the appropriate FW file for the selected card.3. Download the FW to the card. The download has to be done separately for each
card. (At a particular time, FW download is only possible to one card).
Managed Object Class / Hardware Type:
*
Event Type: processingErrorAlarm
Probable Cause: SoftwareDownloadFailure
Severity: warning
116 DN70580522Issue 01A
Troubleshooting Node B
Id:0900d8058022b58dConfidential
200985 - CAN transaction error
73 200985 - CAN transaction error
73.1 Failure Event Report
73.2 Error DescriptionA CAN transaction error occurred. The card will be reset after inconsistency of data during communication over CAN, e.g. message time-outs, unexpected responses or errors while download of the firmware.
As a consequence, cells or calls could potentially be lost. The states of all affected managed objects change accordingly.
73.3 Troubleshooting (LMT)Take the following measures to clear the alarm cause:1. First, reset the addressed card.2. If the fault cannot be cleared by reset, the addressed card has to be replaced.
Replacement must be done according to the “Replacing Node B Units” manual, “Tasklist”.
3. If the card replacement did not clear the fault, contact the technical assistance center (TAC) to get support in isolating the fault. For suitable preparation save the error symptoms as described in “Collect Info for Assistance”. Log files need to be analyzed and specific measures must be taken which are out of the operator’s scope.
Managed Object Class / Hardware Type:
*
Event Type: equipmentAlarm
Probable Cause: EquipmentMalfunction
Severity: warning
DN70580522 Issue 01A
117
Troubleshooting Node B 200986 - Temperature out of range in upper direction
Id:0900d8058022b595Confidential
74 200986 - Temperature out of range in upper direction
74.1 Failure Event Report
74.2 Error DescriptionNormally, this alarm is output when the temperature sensor wired to the ACTC board is not connected. In this case, the temperature may rise to critical values without any threshold alarms being raised.
The alarm may however also occur in combination with the 200996 - Critical Tempera-ture Limit (Ht4) reached alarm. In this case, the temperature at the temperature sensor wired to the ACTC board is out of range in upper direction. The temperature is above +87 °C (188.6 °F). When both the “200986 - Temperature out of range in upper direc-tion” and the “200996 - Critical Temperature Limit (Ht4) reached” alarm are output, immediate further proceeding according to the 200996 - Critical Temperature Limit (Ht4) reached alarm has to be done. Otherwise, severe hardware damage can occur.
g NOTEIf the reporting Node B is of type NB-441/NB-881/NB-861, the lack of air circulation may be caused by a polluted membrane filter (MEF). Therefore, if the Node B site is located in heavily air-polluted environments combined with special temperature con-ditions, a maintenance of the MEF filters in the outdoor NB-441/NB-881/NB-861 might be necessary.
If the MEFs are polluted, the 201029 - MEF blocked or 201035 - MEF completely blocked alarm is output. Refer to the relevant alarm’s error description and follow the troubleshooting.
74.3 Troubleshooting (LMT)The procedure to clear this alarm (“200986 – Temperature out of range in upper direc-tion”) depends on whether or not the “200996 – Critical Temperature Limit (Ht4) reached” alarm is output in combination with this alarm. Proceed as follows:1. Check whether the “200996 – Critical Temperature Limit (Ht4) reached” alarm is
also output.Using the ALARM View window of the LMT, proceed as follows:– Click on the “Alarm View” button or use the shortcut key combination Ctrl + A .– Look for a “200996 – Critical Temperature Limit (Ht4) reached” alarm in the
reporting Node B.2. The further proceeding depends on the result of the analysis in the previous step.
Managed Object Class / Hardware Type:
BaseRack, ServiceRack
Event Type: environmentalAlarm
Probable Cause: HighTemperature
Severity: minor
118 DN70580522Issue 01A
Troubleshooting Node B
Id:0900d8058022b595Confidential
200986 - Temperature out of range in upper direction
– If the “200996 – Critical Temperature Limit (Ht4) reached” alarm is output, proceed according to the troubleshooting of the 200996 – Critical Temperature Limit (Ht4) reached alarm.
– If the “200996 – Critical Temperature Limit (Ht4) reached” alarm is not output, check the sensor connections.
DN70580522 Issue 01A
119
Troubleshooting Node B 200987 - Hardware parameter invalid
Id:0900d8058022b59bConfidential
75 200987 - Hardware parameter invalid
75.1 Failure Event Report
75.2 Error DescriptionThis alarm indicates that an unknown hardware parameter has been received. The reporting card will be reset after it has delivered an unknown hardware parameter.
Normally, this alarm would have been caused by an incompatible hardware configura-tion, a defective database, etc.
In this case, however, the Node B software reports an invalid hardware parameter although neither the hardware configuration nor the Node B database are mismatched! In fact, this is an error in the software which should be reported to customers service.
Due to the reason that this is a software error rather than an incompatibility in the database or hardware configuration, checking or changing the Node B’s database and hardware configuration would not help to solve this alarm.
As a consequence of this failure, cells or calls could potentially be lost. The states of all affected managed objects change accordingly.
75.3 Troubleshooting (LMT)Contact the technical assistance center (TAC) to get support in isolating the fault. For suitable preparation save the error symptoms as described in “Collect Info for Assis-tance”. Log files need to be analyzed and specific measures must be taken which are out of the operator’s scope.
Managed Object Class / Hardware Type:
*
Event Type: processingErrorAlarm
Probable Cause: InvalidParameter
Severity: warning
120 DN70580522Issue 01A
Troubleshooting Node B
Id:0900d8058022b5a3Confidential
200988 - Response unknown
76 200988 - Response unknown
76.1 Failure Event Report
76.2 Error DescriptionA non-fatal software error has occurred. An unknown response has been received.
76.3 Troubleshooting (LMT)Take the following measures to clear the alarm cause:1. Reset the addressed card.2. If the fault could not be cleared by the reset, replace the addressed card.
Replacement must be done according to the “Replacing Node B Units” manual, “Tasklist”.
3. If the fault cannot be cleared by replacement of the card, contact the technical assis-tance center (TAC) to get support in isolating the fault. For suitable preparation save the error symptoms as described in “Collect Info for Assistance”. Log files need to be analyzed and specific measures must be taken which are out of the operator’s scope.
Managed Object Class / Hardware Type:
*
Event Type: processingErrorAlarm
Probable Cause: MessageNotExpected
Severity: warning
DN70580522 Issue 01A
121
Troubleshooting Node B 200989 - No CORBA proxy available for LRU
Id:0900d8058022b5a9Confidential
77 200989 - No CORBA proxy available for LRU
77.1 Failure Event Report
77.2 Error DescriptionThis alarm is output due to the following fatal software error: there is no CORBA (common object request broker architecture) proxy available for the addressed LRU.
After an unsuccessful automatic recovery by means of a reset, the reporting LRU was put out of service.
As a consequence, cells or calls could potentially be lost. The states of all affected managed objects change accordingly.
77.3 Troubleshooting (LMT)Perform the following tasks in the given order to solve this error:1. First, reset the addressed card or external module (such as RRHs).
Use the TREE View window of the LMT and, depending on the reporting managed object, apply the respective command:CAT Cat “reset”CHC Ch “reset”DRIC Dric “reset”DRX Drx “reset”REP Rep “reset”RRH Rrh “reset”TRX Trx “reset”
2. If the fault cannot be cleared by reset, the addressed card has to be replaced. Replacement must be done according to the “Replacing Node B Units” instructions.
3. If the card replacement did not clear the fault, either, contact the technical assis-tance center (TAC) to get support in isolating the fault. For suitable preparation save the error symptoms as described in “Collect Info for Assistance”. Log files need to be analyzed and specific measures must be taken which are out of the operator’s scope.
Managed Object Class / Hardware Type:
Ch, Rep, Trx, Dric, Cat, Rrh, Drx
Event Type: equipmentAlarm
Probable Cause: EquipmentMalfunction
Severity: major (final), handled according to the Fault Escalation Strategy
122 DN70580522Issue 01A
Troubleshooting Node B
Id:0900d8058022b5afConfidential
200990 - No still alive response from LRU
78 200990 - No still alive response from LRU
78.1 Failure Event Report
78.2 Error DescriptionThis alarm message is output due to the following fatal software error: no still alive response from the addressed LRU has been received.
After an unsuccessful automatic recovery by means of a reset, the reporting LRU was put out of service.
The error should be reported to the customers service.
As a consequence, cells or calls could potentially be lost. The states of all affected managed objects change accordingly.
78.3 Troubleshooting (LMT)Perform the following tasks in the given order:1. First, reset the addressed card or external module (such as RRHs).
Use the TREE View window of the LMT and, depending on the reporting managed object, apply the respective command:CAT Cat “reset”CHC Ch “reset”DRIC Dric “reset”DRX Drx “reset”REP Rep “reset”RRH Rrh “reset”TRX Trx “reset”
2. If the fault cannot be cleared by reset, the addressed card/external module has to be replaced. Replacement must be done according to the “Replacing Node B Units” instructions.
3. If the card/external module replacement did not clear the fault, contact the technical assistance center (TAC) to get support in isolating the fault. For suitable preparation save the error symptoms as described in “Collect Info for Assistance”. Log files need to be analyzed and specific measures must be taken which are out of the operator’s scope.
Managed Object Class / Hardware Type:
Ch, Rep, Trx, Dric, Cat, Rrh, Drx
Event Type: equipmentAlarm
Probable Cause: EquipmentMalfunction
Severity: major (final), handled according to the Fault Escalation Strategy
DN70580522 Issue 01A
123
Troubleshooting Node B 200991 - Duplex error
Id:0900d8058022b5b5Confidential
79 200991 - Duplex error
79.1 Failure Event Report
79.2 Error DescriptionThe duplex error occurs in the event of: • Receive logical channel FIFO overrun on duplex. • Loss of signal alarm on duplex. • Loss of cell delineation. • HCS-error on RXD interface on duplex. • Cell delineation state out of sync. • Transmit logical channel FIFO overrun on duplex. • Unable to lock input reference clock on duplex. • Invalid start of cell sequence on utopia input port on duplex.
As a consequence of this failure, service may be affected. Thus, cells or calls could potentially be lost. The states of all affected managed objects change accordingly.
79.3 Troubleshooting (LMT)Perform the following tasks in the given order:1. First, reset the addressed card. Use the TREE View window of the LMT or, alterna-
tively, apply the Cc “reset” command to the addressed card.2. If the fault cannot be cleared by reset, the addressed card has to be replaced.
Replacement must be done according to the “Replacing Node B Units” instructions.3. If the card replacement did not clear the fault, contact the technical assistance
center (TAC) to get support in isolating the fault. For suitable preparation save the error symptoms as described in “Collect Info for Assistance”. Log files need to be analyzed and specific measures must be taken which are out of the operator’s scope.
Managed Object Class / Hardware Type:
Cc
Event Type: equipmentAlarm
Probable Cause: EquipmentMalfunction
Severity: major (final), handled according to the Fault Escalation Strategy
124 DN70580522Issue 01A
Troubleshooting Node B
Id:0900d8058022b5bbConfidential
200992 - Software error
80 200992 - Software error
80.1 Failure Event Report
80.2 Error DescriptionThis error occurs in the event of: • Flash error • CAN receive or transmit queue overflow • Interrupt queue overflow
As a consequence of this failure, service may be affected. Thus, cells or calls could potentially be lost. The states of all affected managed objects change accordingly.
80.3 Troubleshooting (LMT)Perform the following tasks in the given order to solve this error:1. First, reset the addressed card. Use the TREE View window of the LMT or, alterna-
tively, apply the Cc “reset” command to the addressed card.2. If the fault cannot be cleared by reset, the addressed card has to be replaced.
Replacement must be done according to the “Replacing Node B Units” instructions.3. If the card replacement did not clear the fault, contact the technical assistance
center (TAC) to get support in isolating the fault. For suitable preparation save the error symptoms as described in “Collect Info for Assistance”. Log files need to be analyzed and specific measures must be taken which are out of the operator’s scope.
Managed Object Class / Hardware Type:
Cc
Event Type: processingErrorAlarm
Probable Cause: SoftwareError
Severity: critical
DN70580522 Issue 01A
125
Troubleshooting Node B 200993 - Unexpected alarm status bit
Id:0900d8058022b5c1Confidential
81 200993 - Unexpected alarm status bit
81.1 Failure Event Report
81.2 Error DescriptionUnexpected CAN status notification occurs in the event of:
• CRC-8 error for the whole received cell (RXD) on duplex.
• Remote defect indication (RDI) received on LVDS (low voltage differential signal) on duplex.
• SRAM, duplex, EEPROM or CAN voltage error.
As a consequence of this failure, service may be affected. Thus, cells or calls could potentially be lost. The states of all affected managed objects change accordingly.
81.3 Troubleshooting (LMT)Perform the following tasks in the given order to solve this error:1. First, reset the addressed card. Use the TREE View window of the LMT or, alterna-
tively, apply the Cc “reset” command to the addressed card.2. If the fault cannot be cleared by reset, the addressed card has to be replaced.
Replacement must be done according to the “Replacing Node B Units” instructions.3. If the card replacement did not clear the fault, contact the technical assistance
center (TAC) to get support in isolating the fault. For suitable preparation save the error symptoms as described in “Collect Info for Assistance”. Log files need to be analyzed and specific measures must be taken which are out of the operator’s scope.
Managed Object Class / Hardware Type:
Cc
Event Type: processingErrorAlarm
Probable Cause: CorruptData
Severity: critical
126 DN70580522Issue 01A
Troubleshooting Node B
Id:0900d8058022b5c7Confidential
200994 - Hardware Failure
82 200994 - Hardware Failure
82.1 Failure Event Report
82.2 Error DescriptionThis alarm is output in the event of: • PLL of DC/DC-unit unlocked • Voltage or current out of range • Insufficient or excess temperature on DC/DC-unit • HSDPA throughput degraded • Boot parameter check failure
The different errors can be distinguished by means of the “Additional Text” field in this alarm’s row (ALARM View window of the LMT or “Alarm Monitoring” application of the Radio Commander).
82.3 Troubleshooting (LMT)If the alarm is output due to the “Boot parameter check failure”, contact the the technical assistance center (TAC) before resetting or replacing equipment. For suitable prepara-tion save the error symptoms as described in “Collect Info for Assistance”. Log files need to be analyzed and specific measures must be taken which are out of the operator’s scope.
Perform the following tasks in the given order to solve this error:1. First, reset the addressed card. Use the TREE View window of the LMT and apply
the Cc “reset” command to the addressed card.2. If the fault cannot be cleared by reset, the addressed card has to be replaced.
Replacement must be done according to the “Replacing Node B Units” instructions.3. If the card replacement did not clear the fault, contact the technical assistance
center (TAC) to get support in isolating the fault. For suitable preparation save the error symptoms as described in “Collect Info for Assistance”. Log files need to be analyzed and specific measures must be taken which are out of the operator’s scope.
Managed Object Class / Hardware Type:
Cc
Event Type: equipmentAlarm
Probable Cause: EquipmentFailure
Severity: minor
DN70580522 Issue 01A
127
Troubleshooting Node B 200995 - High Temperature Limit (Ht3) reached
Id:0900d8058022b5cfConfidential
83 200995 - High Temperature Limit (Ht3) reached
83.1 Failure Event Report
83.2 Error DescriptionThe Node B rack/shelter internal temperature has reached a high level (Ht3). If the tem-perature increases further (by 2 °C, which is equivalent to 3.6 °F) the critical level (Ht4) will be reached. See also 200996 - Critical Temperature Limit (Ht4) reached. The tem-perature level depends on the Node B type and is as follows:
• NB-441/NB-881/NB-861: Ht3 = 63 °C (125.6 °F) • NB-440/NB-880/RS-880/RSSU-380: Ht3 = 59 °C (138.2 °F) • NB-420/NB-860: Ht3 = 61 °C (141.8 °F) • NB-341/RS-381: Ht3 = 70 °C (158 °F)
This alarm message may occur in conjunction with 200920 - High temperature of PA and 200921 - Over temperature of PA.
This alarm is cleared if the temperature decreases to the Ht2 level, which depends also on the Node B type:
• NB-441/NB-881/NB-861: Ht2 = 52 °C (125.6 °F) • NB-440/NB-880/RS-880/RSSU-380: Ht2 = 47 °C (116.6 °F) • NB-420/NB-860: Ht2 = 47 °C (116.6 °F) • NB-341/RS-381: Ht2 = 65 °C (149 °F)
g NOTEIf the reporting Node B is of type NB-441/NB-881/NB-861, this alarm may be caused by a polluted membrane filter (MEF). Therefore, if the Node B site is located in heavily air-polluted environments combined with special temperature conditions, a maintenance of the MEF filters in the outdoor NB-441/NB-881/NB-861 might be nec-essary.
If the MEFs are polluted, the 201029 - MEF blocked or 201035 - MEF completely blocked alarm is output. Refer to the relevant alarm’s error description and follow the troubleshooting.
83.3 Troubleshooting (LMT)First, contact the technical assistance center (TAC) to get support in isolating the fault. For suitable preparation save the error symptoms as described in “Collect Info for Assis-
Managed Object Class / Hardware Type:
BaseRack, ServiceRack
Event Type: environmentalAlarm
Probable Cause: HighTemperature
Severity: major
128 DN70580522Issue 01A
Troubleshooting Node B
Id:0900d8058022b5cfConfidential
200995 - High Temperature Limit (Ht3) reached
tance”. Log files need to be analyzed and specific measures must be taken which are out of the operator’s scope.
Additional fan alarms such as “200914 – Fan unit failed” may indicate the basic cause.
For indoor Node Bs:1. Check the fan units.2. Is the environmental temperature in the specified range?
For outdoor Node Bs:1. Check the fan units.2. Are the air in- and outlets free from air stream blocking material?3. Make sure the heater units are not switched on undesignedly.
DN70580522 Issue 01A
129
Troubleshooting Node B 200996 - Critical Temperature Limit (Ht4) reached
Id:0900d8058022b5d5Confidential
84 200996 - Critical Temperature Limit (Ht4) reached
84.1 Failure Event Report
84.2 Error DescriptionThe Node B rack/shelter internal temperature has reached a critical level (Ht4). An immediate operator action is required: Switch off the Node B! Otherwise a severe hardware damage can occur.
The temperature level depends on the Node B type and is as follows:
• NB-441/NB-881/NB-861: Ht4 = 65 °C (149 °F) • NB-440/NB-880/RS-880/RSSU-380: Ht4 = 61 °C (141.8 °F) • NB-420/NB-860: Ht4 = 63 °C (145.4 °F) • NB-341/RS-381: Ht4 = 72 °C (161.6 °F)
This alarm message may occur in conjunction with 200920 - High temperature of PA, 200921 - Over temperature of PA, and 200986 - Temperature out of range in upper direction.
This alarm is cleared if the temperature decreases to the Ht2 level, which depends also on the Node B type:
• NB-441/NB-881/NB-861: Ht2 = 52 °C (125.6 °F) • NB-440/NB-880/RS-880/RSSU-380: Ht2 = 47 °C (116.6 °F) • NB-420/NB-860: Ht2 = 47 °C (116.6 °F) • NB-341/RS-381: Ht2 = 65 °C (149 °F)
g NOTEIf the reporting Node B is of type NB-441/NB-881/NB-861, this alarm may be caused by a polluted membrane filter (MEF). Therefore, if the Node B site is located in heavily air-polluted environments combined with special temperature conditions, a maintenance of the MEF filters in the outdoor NB-441/NB-881/NB-861 might be nec-essary.
If the MEFs are polluted, the 201029 - MEF blocked or 201035 - MEF completely blocked alarm is output. Refer to the relevant alarm’s error description and follow the troubleshooting.
84.3 Troubleshooting (LMT)g NOTE
Managed Object Class / Hardware Type:
BaseRack, ServiceRack
Event Type: environmentalAlarm
Probable Cause: HighTemperature
Severity: major
130 DN70580522Issue 01A
Troubleshooting Node B
Id:0900d8058022b5d5Confidential
200996 - Critical Temperature Limit (Ht4) reached
An overtemperature scenario in the Node B can lead to a self-disabling of B-shelf cards. The Node B handles self-disabled cards as if a fatal board failure, such as an on-board power supply failure, has occurred. In other words, the combination of OST/AVS then changes to disabled/not installed and the LED of the self-disabled card is off.
Switch off the Node B immediately! Otherwise, severe hardware damage can occur.
Additional fan alarms such as 200914 - Fan unit failed may indicate the basic cause.
For indoor Node Bs:1. Check the fan units.
Use the LMT’s TREE View window and apply the Fan “Get All Attributes” command to all related fan units.
2. Is the environmental temperature in the specified range?
For outdoor Node Bs:1. Check the fan units.
Use the LMT’s TREE View window and apply the Fan “Get All Attributes” command to all related fan units.
2. Are the air in- and outlets free from air stream blocking material?Perform a visual inspection and, if necessary, preventive maintenance tasks on site (check the air filter, heat exchanger). Both tasks must be done according to the “Replacing Node B Units” instructions.
3. Make sure the heater units are not switched on undesignedly.
DN70580522 Issue 01A
131
Troubleshooting Node B 200997 - Lower Temperature Limit (Ht0) reached
Id:0900d8058022b5ddConfidential
85 200997 - Lower Temperature Limit (Ht0) reached
85.1 Failure Event Report
85.2 Error Description The Node B rack/shelter internal temperature has reached the lower limit (Ht0). Below this temperature electronic equipment does not work reliably.
The temperature level for all Node B types is: • Ht0 = -5 °C (23 °F)
This alarm is cleared, if the temperature increases to the Ht1 level, which is Node B dependent: • NB-441/NB-881/NB-881 HR/NB-861: Ht1 = 5 °C (41 °F) • NB-440/NB-880/NB-580/RS-880/RSSU-380: Ht1 = 5 °C (41 °F) • NB-420/NB-860: Ht1 = 5 °C (41 °F) • NB-341/RS-381: Ht1 = 0 °C (32 °F)
85.3 Troubleshooting (LMT)Even the Node B’s own power dissipation is not sufficient to keep the rack/shelter internal temperature above the lowest operating limit.
Take the following measures to clear the alarm cause: • For indoor Node Bs:
Rooms with electronic equipment are usually temperature-controlled by radiators and/or air condition systems:– Check radiator for sufficient heating– Check windows, doors etc. for perfect closing (infiltration)
• For outdoor Node Bs:– Are heater units installed for keeping the shelter internal temperature above -
5°C (23 °F) under worst environmental conditions?– Do the heater units work? Check the power supply, proper connection, and
ohmic resistance.– Replace the heater units if identified as defective.
Replacement must be done according to the “Replacing Node B Units” manual, “Tasklist”.
Managed Object Class / Hardware Type:
BaseRack, ServiceRack
Event Type: environmentalAlarm
Probable Cause: LowTemperature
Severity: minor
132 DN70580522Issue 01A
Troubleshooting Node B
Id:0900d8058022b5e5Confidential
200998 - Temperature out of range in lower direction
86 200998 - Temperature out of range in lower direction
86.1 Failure Event Report
86.2 Error Description The temperature at the temperature sensor wired to the ACT is out of range in lower direction.
The temperature is below: • NB-441/NB-881/NB-861: -8 °C (17.6 °F) • NB-440/NB-880/RS-880/RSSU-380: -8 °C (17.6 °F) • NB-420/NB-860: -8 °C (17.6 °F) • NB-341/RS-381: -10 °C (14 °F)
This error message occurs also, if there is a short-circuit in the sensor or in the wires between sensor and ACT.
86.3 Troubleshooting (LMT)Even the Node Bs own power dissipation is not sufficient to keep the rack/shelter internal temperature above the lowest operating limit.
• For indoor Node Bs:Rooms with electronic equipment are usually temperature controlled by radiators and/or air condition systems:– Check radiator for sufficient heating.– Check windows, doors etc. for perfect closing (infiltration).
• For outdoor Node Bs:– Are heater units installed for keeping the shelter internal temperature above -
5 °C (23 °F) under worst environmental conditions?– Do the heater units work? Check the power supply, proper connection, and
ohmic resistance.– Replace the heater units if identified as defective. Replacement must be done
according to the “Replacing Node B Units” manual, “Tasklist”. • Check the temperature sensor and the wires to the ACT for a short-circuit if none of
the above reasons were identified.
Managed Object Class / Hardware Type:
BaseRack, ServiceRack
Event Type: environmentalAlarm
Probable Cause: LowTemperature
Severity: minor
DN70580522 Issue 01A
133
Troubleshooting Node B 200999 - Unexpected loss of unlocked LRU
Id:0900d8058022b5ebConfidential
87 200999 - Unexpected loss of unlocked LRU
87.1 Failure Event Report
87.2 Error DescriptionThe mentioned LRU was unmounted without being locked before. The unexpected loss of an unlocked LRU can be caused by one of the following: • Extracting the reporting LRU or disconnecting the cable at the DRIF (CPRI) to the
reporting internal or external module (such as CATs or RRHs, respectively) without setting the administrative state (AST) to locked before
• Occurrance of a fatal LRU failure • Self-disabling of the reporting LRU due to an overtemperature scenario
As a consequence of this scenario, cells or calls could potentially be lost. The states of all affected managed objects thus change accordingly.The Node B handles self-disabled LRUs as if a fatal LRU failure, such as an on-board power supply failure, has occurred. In other words, the combination of OST/AVS changes to disabled/not installed and the LED of the self-disabled LRU is off.g NOTE
If the reporting Node B is of type NB-441/NB-881/NB-861, the self-disabling of the reporting card may be caused by a polluted membrane filter (MEF). There-fore, if the Node B site is located in heavily air-polluted environments combined with special temperature conditions, a maintenance of the MEF filters in the outdoor NB-441/NB-881/NB-861 might be necessary.If the MEFs are polluted, the 201029 - MEF blocked or 201035 - MEF completely blocked alarm is output. Refer to the relevant alarm’s error description and follow the troubleshooting.
If this fatal board failure occurs, even a CAN communication is not possible anymore.
87.3 Troubleshooting (LMT)Depending on the current situation due to which this fault occurred, perform one of the following procedures to cease this alarm: • If this alarm occurs in combination with the “200914 – Fan unit failed” alarm and/or
the “200996 – Critical Temperature Limit (Ht4) reached” alarm, the probability is very high that the reporting LRU disabled itself due to an overtemperature scenario.Further repair actions must be done according to the “Replacing Node B Units” instructions.
• If the LRU was plugged out by mistake, just install the LRU again.
Managed Object Class / Hardware Type:
*
Event Type: equipmentAlarm
Probable Cause: EquipmentFailure
Severity: critical
134 DN70580522Issue 01A
Troubleshooting Node B
Id:0900d8058022b5ebConfidential
200999 - Unexpected loss of unlocked LRU
• If the cable at the CPRI interface (between DRIC and CAT/RRH/DRX) was discon-nected by mistake, connect the cable again.
• If the card is not to be used anymore, perform a lock and unlock operation, using the TREE View window of the LMT.g NOTE
If an LPA, a DUAMCO, a TRX, a CAT, or a RRH has to be locked and unlocked, apply the following procedure:1. Deactivate the related WCDMA cell, using the RNC’s element manager or
NetAct.2. Lock the LPA, DUAMCO, TRX, CAT, or RRH.
Use the TREE View window and, depending on the reporting hardware type, apply the following command:– Lpa “Set administrativeState Locked”– Duamco “Set administrativeState Locked”– Trx “Set administrativeState Locked”– Cat “Set administrativeState Locked”– Rrh “Set administrativeState Locked”
3. Unlock the LPA, DUAMCO, TRX, CAT, or RRH.Use the TREE View window and, depending on the reporting HW type, apply the following command:– Lpa “Set administrativeState Unlocked”– Duamco “Set administrativeState Unlocked”– Trx “Set administrativeState Unlocked”– Cat “Set administrativeState Unlocked”– Rrh “Set administrativeState Unlocked”
4. Activate the related WCDMA cell, using the RNC’s element manager or NetAct.
• If the LRU is still plugged in, a board failure occurred and the addressed LRU has to be replaced. Replacement must be done according to the “Replacing Node B Units” instructions.
!WARNING: Radiation from laser devices (EN 60825/IEC 60825).
Damage of health may occur.
To avoid damage to health, you must observe the regulations regarding protection against radiation from laser devices (EN 60825/IEC 60825). • You must always use dedicated laser-protective goggles. • Never look into open fiber-optic cable ends, as this may damage your eyes.
DN70580522 Issue 01A
135
Troubleshooting Node B 201001 - RET power off
Id:0900d8058022b5f1Confidential
88 201001 - RET power off
88.1 Failure Event Report
88.2 Error DescriptionThe addressed RET module is switched off at the POWER ON/OFF switch, but not defective. This mode is indicated by the RET LED which is off. Most likely, this alarm is raised during normal Node B operation if the DIP switch 6 of the corresponding DIP switch group is set to OFF position by accident.
Please switch on the RET module.
This alarm will only be output if the power status of the RET module has changed from ON to OFF during operation. However, if the RET module is already switched off at boot time of the Node B, this alarm will not be raised.
• If the RET is supplied by a DUAMCO:For RET recovery, a reset of the related DUAMCO is required in order to re-estab-lish the communication between DUAMCO and RET. A reset of the RET managed object is not possible while this failure exists.
• If the RET is supplied by a DRX:For RET recovery, a reset of the RET itself is sufficient to re-establish the commu-nication.
For RET recovery, a reset of the related DUAMCO is required in order to re-establish the communication between DUAMCO and RET. A reset of the RET managed object is not possible while this failure exists.
88.3 Troubleshooting (LMT)
If the DIP switch 6 was set to the OFF position by accident, perform the following steps in the given order:1. Confirm that the power is supplied to the relevant RET module from DUAMCO or
DRX. Check the cables, and switch the POWER ON/OFF DIP switch 6 in position ON.
Managed Object Class / Hardware Type:
Ret
Event Type: environmentalAlarm
Probable Cause: ExternalPowerSupplyFailure
Severity: minor
!DANGER: Uncontrolled emission of microwave radiation.
Damage of health may occur.
To avoid the danger of an uncontrolled emission of microwave radiation, switch off the breakers for the related LPAs/CATs before replacing antenna cables, antennas, RET, or DUAMCO.
136 DN70580522Issue 01A
Troubleshooting Node B
Id:0900d8058022b5f1Confidential
201001 - RET power off
2. The further proceeding depends on whether the RET is supplied by a DUAMCO or a DRX:– If the RET is supplied by a DUAMCO, reset the relevant DUAMCO managed
object. Use the TREE View window of the LMT and apply the Duamco “reset” command to the relevant managed object.
– If the RET is supplied by a DRX, reset the reporting RET. Use the TREE View window of the LMT and apply the Ret “reset” command to the relevant managed object.
DN70580522 Issue 01A
137
Troubleshooting Node B 201002 - RET feeder alarm
Id:0900d8058022b5f7Confidential
89 201002 - RET feeder alarm
89.1 Failure Event Report
89.2 Error DescriptionRET operations of the reporting module are not possible because the 2.176 MHz carrier between the DUAMCO and DTMARET or the cable between DTMARET and RET is defective.
In correct configurations of the Node B (according to installation and configuration guidelines), this alarm should not occur at all. This alarm is designed for possible appli-cations in the future when no TMA will be used. If the carrier is defective in the current configuration, the alarms 200910 - TMA feeder alarm and 201004 - RET communication error are output.
However, the RET feeder alarm may be caused by a wrong configuration of the Node B: whenever a DTMARET (supporting RET) and a DUAMCORT (without RET support) are installed in the same Node B, this alarm is output. As a consequence of the wrong con-figuration, the 200910 – TMA feeder alarm may also be output.
For RET recovery a reset of the related DUAMCO is required in order to re-establish the communication between DUAMCO and RET. A reset of the RET managed object is not possible while this failure exists.
89.3 Troubleshooting (LMT)
In order to solve this error, perform the following steps in the given order:1. Confirm that the cables between RET and DUAMCO are connected properly.2. Reset the relevant DUAMCO.
Use the TREE View window of the LMT and apply the Duamco “reset” command to the respective managed object.
3. If the above actins could not clear this alarm, check whether the 200910 – TMA feeder alarm is also output. This may be a strong indicator for a wrong configuration
Managed Object Class / Hardware Type:
Ret
Event Type: equipmentAlarm
Probable Cause: ReceiverFailure
Severity: minor
!DANGER: Uncontrolled emission of microwave radiation.
Damage of health may occur.
To avoid the danger of an uncontrolled emission of microwave radiation, switch off the breakers for the related LPAs/CATs before replacing antenna cables, antennas, RET, or DUAMCO.
138 DN70580522Issue 01A
Troubleshooting Node B
Id:0900d8058022b5f7Confidential
201002 - RET feeder alarm
of the Node B, i.e. installation of a DTMARET (supporting RET) and a DUAMCORT (without RET support).To solve this error, replace the DUAMCORT with a DUAMCORET (supporting RET). Replacement must be done according to the “Replacing Node B Units” instructions.
4. If the alarm has not ceased yet, the defective RET module must be replaced. Since both the RET module and the antenna are OEM products, replacement must be done according to the OEM vendor’s description.
DN70580522 Issue 01A
139
Troubleshooting Node B 201003 - RET hardware alarm
Id:0900d8058022b5ffConfidential
90 201003 - RET hardware alarm
90.1 Failure Event Report
90.2 Error DescriptionThe addressed RET module reported a hardware error, such as a motor jam or an EPROM error.
90.3 Troubleshooting (LMT)
Perform the following steps in the given order to solve this error:1. Replace the defective RET module. Since both the RET module and the antenna are
OEM products, replacement must be done according to the OEM vendor’s descrip-tion.
2. If the card replacement did not clear the fault, contact the technical assistance center (TAC) to get support in isolating the fault. For suitable preparation save the error symptoms as described in “Collect Info for Assistance”. Log files need to be analyzed and specific measures must be taken which are out of the operator’s scope.
Managed Object Class / Hardware Type:
Ret
Event Type: equipmentAlarm
Probable Cause: EquipmentFailure
Severity: minor
!DANGER: Uncontrolled emission of microwave radiation.
Damage of health may occur.
To avoid the danger of an uncontrolled emission of microwave radiation, switch off the breakers for the related LPAs/CATs before replacing antenna cables, antennas, RET, or DUAMCO.
140 DN70580522Issue 01A
Troubleshooting Node B
Id:0900d8058022b605Confidential
201004 - ALD communication error
91 201004 - ALD communication error
91.1 Failure Event Report
91.2 Error DescriptionThe addressed antenna line device (ALD), i.e. RET or TMA module, reported a commu-nication error, such as a signaling interrupt. This alarm may be caused by one of the fol-lowing:
• An error occurred on the serial communication line (RS485) between RET/TMA and its controlling device (DUAMCO, RRH, or DRX).
• The cable toward the RET/TMA module is defective. • The communication to the RET/TMA module could not be established. • This alarm is output at the RET as a consequence of 200910 - TMA feeder alarm,
occurring whenever the 2.176 MHz carrier between DUAMCO and DTMARET or the cable between DTMARET and RET is defective.
• The reporting RET or TMA is supplied by a DUAMCO:For RET/TMA recovery, a reset of the related DUAMCO and the addressed RET/TMA is required in order to re-establish the communication between DUAMCO and RET/TMA. Only resetting the RET/TMA managed object is not possible while this failure exists.
• The reporting RET or TMA is supplied by an RRH or a DRX:For RET/TMA recovery, a reset of the RET itself is sufficient to re-establish the com-munication.
91.3 Troubleshooting (LMT)
First, check whether alarm 200910 - TMA feeder alarm is output. If this alarm has occurred before, eliminate the cause of the fault. Proceed according to the troubleshoot-ing of 200910 - TMA feeder alarm. This may clear the communication error of the antenna line device (RET or TMA), as well.
Managed Object Class / Hardware Type:
Ret, Tma
Event Type: communicationsAlarm
Probable Cause: CommunicationProtocolError
Severity: minor
!DANGER: Uncontrolled emission of microwave radiation.
Damage of health may occur.
To avoid the danger of an uncontrolled emission of microwave radiation, switch off the breakers for the related LPAs/CATs before replacing antenna cables, antennas, RET, or DUAMCO.
DN70580522 Issue 01A
141
Troubleshooting Node B 201004 - ALD communication error
Id:0900d8058022b605Confidential
If either the TMA feeder alarm did not occur or the measures taken above did not clear this fault, perform the following steps in the given order:1. Confirm that the cables between RET/TMA and its controlling device (DUAMCO,
RRH, or DRX) are connected properly.2. The further proceeding depends on whether or not the reporting RET/TMA is con-
trolled by a DUAMCO:– If the RET/TMA is controlled by a DUAMCO, continue with step (3).– Otherwise, if the RET/TMA is not controlled by a DUAMCO, skip step (3) and
continue with step (4).3. Reset the relevant DUAMCO managed object.
Use the TREE View window of the LMT and apply the Duamco “reset” command to the relevant managed object.
4. Reset the addressed RET/TMA managed object.– For RET: use the TREE View window of the LMT and apply the Ret “reset”
command to the relevant RET managed object.– For TMA: use the TREE View window of the LMT and apply the Tma “reset”
command to the relevant TMA managed object.5. If the alarm is still active, replace the defective RET/TMA module.
– RET replacement: Since both the RET module and the antenna are OEM prod-ucts, replacement must be done according to the OEM vendor’s description.
– TMA replacement: Replacement must be done according to the “Replacing Node B Units” instructions.
6. If the card replacement did not clear the fault, contact the technical assistance center (TAC) to get support in isolating the fault. For suitable preparation save the error symptoms as described in “Collect Info for Assistance”. Log files need to be analyzed and specific measures must be taken which are out of the operator’s scope.
142 DN70580522Issue 01A
Troubleshooting Node B
Id:0900d8058022b60bConfidential
201005 - RET is not calibrated
92 201005 - RET is not calibrated
92.1 Failure Event Report
92.2 Error DescriptionThe reporting RET module is disabled because it is not calibrated. Both the RET module and the antenna have to be calibrated after installation. The stepper motor drives to the end position.
To solve this error, the addressed RET module has to be calibrated.
92.3 Troubleshooting (LMT)
Perform the following tasks in the order described to solve this error:1. Check the antenna for mechanical problems.
Since antennas are OEM products, proceed according to the OEM vendor’s descrip-tion.
2. Check the mechanical calibration of the antenna and, if necessary, calibrate the antenna again.As antennas are OEM products, proceed according to the OEM vendor’s descrip-tion.
3. If the alarm condition had not been caused by the antenna, calibrate the relevant RET moduleUse the TREE View window of the LMT and apply the Ret “calibrate” action command to the reporting managed object.
4. Contact the technical assistance center (TAC) to get support in isolating the fault. For suitable preparation save the error symptoms as described in “Collect Info for Assistance”. Log files need to be analyzed and specific measures must be taken which are out of the operator’s scope.
Managed Object Class / Hardware Type:
Ret
Event Type: equipmentAlarm
Probable Cause: ExternalIFDeviceProblem
Severity: minor
!DANGER! Emission of microwave radiation.
Damage to health may occur because the electromagnetic field (EMF) generated by a Node B may have detrimental effects on human health. This danger arises especially – but not exclusively! – in areas very close to the Node B antenna, where EMF levels can be high enough to cause human tissue heating.
To avoid the danger of uncontrolled emission of microwave radiation, switch off the breakers for the related amplifiers before checking antenna cables, antennas, or RETs on site. Furthermore, keep the required distance to the antenna system as described in the antenna documentation.
DN70580522 Issue 01A
143
Troubleshooting Node B 201006 - RET is not scaled
Id:0900d8058022b611Confidential
93 201006 - RET is not scaled
93.1 Failure Event Report
93.2 Error DescriptionThe reporting RET module is disabled because it is not scaled. In other words, the trans-lation table has not been downloaded to the relevant RET module.
The spindle scale table of the relevant RET module must be re-programmed.
93.3 Troubleshooting (LMT)1. Upload the relevant configuration data.
As a precondition, the relevant RET module must be accessible to connect the RS485 interface.To upload (and update) the RET configuration data, use the TREE View window of the LMT and apply the Ret “updateTable” command to the reporting managed object.g Please note that the “201005 – RET is not calibrated” alarm is usually output
after having finished this step!2. Contact the technical assistance center (TAC) to get support in isolating the fault.
For suitable preparation save the error symptoms as described in “Collect Info for Assistance”. Log files need to be analyzed and specific measures must be taken which are out of the operator’s scope.
Managed Object Class / Hardware Type:
Ret
Event Type: equipmentAlarm
Probable Cause: ExternalIFDeviceProblem
Severity: minor
144 DN70580522Issue 01A
Troubleshooting Node B
Id:0900d8058022b617Confidential
201007 - RET lost position
94 201007 - RET lost position
94.1 Failure Event Report
94.2 Error DescriptionThe reporting RET module lost position of the stepper motor and is therefore disabled. The relevant RET module must be calibrated again.
This alarm may occur if the power supply was interrupted while adjusting the antenna tilt.
94.3 Troubleshooting (LMT)Perform the following steps in the given order to solve this error:1. First, calibrate the relevant RET module
Use the TREE View window of the LMT and apply the Ret “calibrate” action command to the reporting managed object.
2. Set the tilt value of the reporting RET moduleUse the TREE View window of the LMT and apply the Ret “setTilt” action command to this Ret managed object.
3. Contact the technical assistance center (TAC) to get support in isolating the fault. For suitable preparation save the error symptoms as described in “Collect Info for Assistance”. Log files need to be analyzed and specific measures must be taken which are out of the operator’s scope.
Managed Object Class / Hardware Type:
Ret
Event Type: equipmentAlarm
Probable Cause: ExternalIFDeviceProblem
Severity: minor
DN70580522 Issue 01A
145
Troubleshooting Node B 201008 - RET received wrong configuration data
Id:0900d8058022b61dConfidential
95 201008 - RET received wrong configuration data
95.1 Failure Event Report
95.2 Error DescriptionThe addressed RET module received wrong configuration data and is therefore dis-abled.
Setting the appropriate configuration data may be required after installation of any RET module unless this task has already been performed by the vendor before delivery. It loads vendor and antenna specific configuration data to establish the relationship between the movement of the drive system and the beam position of the antenna.
95.3 Troubleshooting (LMT)
In order to solve this error, perform the following steps in the given order:1. Check whether the correct configuration data (antenna type and antenna OEM
vendor) is used.– If the configuration data is OK, go to step (2).– Otherwise, if the configuration data is NG, the correct configuration data must be
uploaded using the LMT. To upload and update the RET configuration data, use the TREE View window of the LMT or, alternatively, apply the Ret “updateTable” command to the reporting RET.
2. Confirm that the cables between the RET and DUAMCO modules are connected properly.
3. If the alarm is still active, replace the defective RET module. Since both the RET module and the antenna are OEM products, replacement must be done according to the OEM vendor’s description.
4. If the card replacement did not clear the fault, contact the technical assistance center (TAC) to get support in isolating the fault. For suitable preparation save the error symptoms as described in “Collect Info for Assistance”. Log files need to be
Managed Object Class / Hardware Type:
Ret
Event Type: communicationsAlarm
Probable Cause: CommunicationProtocolError
Severity: minor
!DANGER: Uncontrolled emission of microwave radiation.
Damage of health may occur.
To avoid the danger of an uncontrolled emission of microwave radiation, switch off the breakers for the related LPAs/CATs before replacing antenna cables, antennas, RET, or DUAMCO.
146 DN70580522Issue 01A
Troubleshooting Node B
Id:0900d8058022b61dConfidential
201008 - RET received wrong configuration data
analyzed and specific measures must be taken which are out of the operator’s scope.
DN70580522 Issue 01A
147
Troubleshooting Node B 201009 - A mounted card is not used to its full capacity
Id:0900d8058022b625Confidential
96 201009 - A mounted card is not used to its full capacity
96.1 Failure Event Report
96.2 Error DescriptionThe Node B's configuration does not use the mounted card's full capacity and/or fea-tures. This could be an unwanted waste of resources.
96.3 Troubleshooting (LMT)In order to solve this error, perform the following steps in the given order:1. Check the hardware compatibility of the configuration.2. Replace the incompatible card.
Replacement must be done according to the “Replacing Node B Units” manual, “Tasklist”.
3. If the error has not ceased yet, contact the technical assistance center (TAC) to get support in isolating the fault. For suitable preparation save the error symptoms as described in “Collect Info for Assistance”. Log files need to be analyzed and specific measures must be taken which are out of the operator’s scope.
Managed Object Class / Hardware Type:
*
Event Type: processingErrorAlarm
Probable Cause: ConfigurationOrCustomizationError
Severity: warning
148 DN70580522Issue 01A
Troubleshooting Node B
Id:0900d8058022b62dConfidential
201010 - An incompatible card is mounted
97 201010 - An incompatible card is mounted
97.1 Failure Event Report
97.2 Error DescriptionThe mounted card does not fulfill the Node B's configuration requirements.
97.3 Troubleshooting (LMT)In order to solve this error, perform the following steps in the given order:1. Check the hardware compatibility of the configuration.2. Replace the incompatible card.
Replacement must be done according to the “Replacing Node B Units” manual, “Tasklist”.
3. If the error has not ceased yet, contact the technical assistance center (TAC) to get support in isolating the fault. For suitable preparation save the error symptoms as described in “Collect Info for Assistance”. Log files need to be analyzed and specific measures must be taken which are out of the operator’s scope.
Managed Object Class / Hardware Type:
*
Event Type: processingErrorAlarm
Probable Cause: ConfigurationOrCustomizationError
Severity: major
DN70580522 Issue 01A
149
Troubleshooting Node B 201011 - Alignment of standby CC failed
Id:0900d8058022b633Confidential
98 201011 - Alignment of standby CC failed
98.1 Failure Event Report
98.2 Error DescriptionThe alignment of the standby CC failed. The error should be reported to customer ser-vices. It is possible that a hardware or software error is the root of the problem.
98.3 Troubleshooting (LMT)Take the following steps to solve this error:1. First, reset the relevant card. Use the TREE View window of the LMT or, alterna-
tively, apply the Cc “reset” command to the addressed card.2. If the manual reset did not clear the fault, contact the technical assistance center
(TAC) to get support in isolating the fault. For suitable preparation save the error symptoms as described in “Collect Info for Assistance”. Log files need to be analyzed and specific measures must be taken which are out of the operator’s scope.
Managed Object Class / Hardware Type:
Cc
Event Type: processingErrorAlarm
Probable Cause: FileError
Severity: major (final), handled according to the Fault Escalation Strategy
150 DN70580522Issue 01A
Troubleshooting Node B
Id:0900d8058022b639Confidential
201012 - Timeout for connection to standby CC
99 201012 - Timeout for connection to standby CC
99.1 Failure Event Report
99.2 Error DescriptionAn expected message from the standby CC did not come in time. The error should be reported to customer services. It is possible that a hardware or software error is the root of the problem.
99.3 Troubleshooting (LMT)In order to solve this error, perform the following steps in the given order:1. Reset the relevant card. Use the TREE View window of the LMT or, alternatively,
apply the Cc “reset” command to the addressed card.2. If the manual reset did not clear the fault, contact the technical assistance center
(TAC) to get support in isolating the fault. For suitable preparation save the error symptoms as described in “Collect Info for Assistance”. Log files need to be analyzed and specific measures must be taken which are out of the operator’s scope.
Managed Object Class / Hardware Type:
Cc
Event Type: processingErrorAlarm
Probable Cause: TimeoutExpired
Severity: major
DN70580522 Issue 01A
151
Troubleshooting Node B 201013 - Connection failure to standby CC
Id:0900d8058022b63fConfidential
100 201013 - Connection failure to standby CC
100.1 Failure Event Report
100.2 Error DescriptionAn attempt to connect to the standby CC failed. The error should be reported to customer services. It is possible that a hardware or software error is the root of the problem.
100.3 Troubleshooting (LMT)In order to solve this error, perform the following steps in the given order:1. Reset the addressed standby CC. Use the TREE View window of the LMT or, alter-
natively, apply the Cc “reset” command to the addressed card.2. Confirm that the relevant standby CC card is properly plugged into its slot.3. If the manual reset did not clear the fault, contact the technical assistance center
(TAC) to get support in isolating the fault. For suitable preparation save the error symptoms as described in “Collect Info for Assistance”. Log files need to be analyzed and specific measures must be taken which are out of the operator’s scope.
Managed Object Class / Hardware Type:
Cc
Event Type: equipmentAlarm
Probable Cause: LinkFailure
Severity: major
152 DN70580522Issue 01A
Troubleshooting Node B
Id:0900d8058022b645Confidential
201014 - Standby CC forced to become active due to unreachable active CC
101 201014 - Standby CC forced to become active due to unreachable active CC
101.1 Failure Event Report
101.2 Error DescriptionThe former standby CC was not able to connect with the expected active CC and now became active. Please note that this CC became active due to a recovery action and might not contain the expected configuration. The other CC was not able to become active, thus it should be replaced.
101.3 Troubleshooting (LMT)In order to solve this error, perform the following steps in the given order:1. Replace that CC which is in standby mode now and used to be active before.
Replacement must be done according to the “Replacing Node B Units” instructions.2. Confirm that the Node B is configured properly. Check the Node B’s versions of
database and SW load.Use the TREE View window of the LMT or apply the Osu “validateFile” command to the relevant Osu object.
3. Perform a switch-over of the standby CC. This CC will then become active.Take the following steps in the order provided:– Reset the standby CC, using the TREE View window of the LMT or, alterna-
tively, applying the Cc “reset” command to the standby CC.– Perform the actual switch-over. Use the TREE View window or apply the Cc
“redundancySwitch” command to the CC reset before.4. If the measures taken above did not clear the fault, contact the technical assistance
center (TAC) to get support in isolating the fault. For suitable preparation save the error symptoms as described in “Collect Info for Assistance”. Log files need to be analyzed and specific measures must be taken which are out of the operator’s scope.
Managed Object Class / Hardware Type:
Cc
Event Type: processingErrorAlarm
Probable Cause: CorruptData
Severity: warning
DN70580522 Issue 01A
153
Troubleshooting Node B 201015 - Preparation of data to be aligned has failed
Id:0900d8058022b64bConfidential
102 201015 - Preparation of data to be aligned has failed
102.1 Failure Event Report
102.2 Error DescriptionData which has to be aligned could not be prepared. As a consequence, the standby CC will not be aligned correctly. The error should be reported to customer services. It is possible that a hardware or software error is the root of the problem.
102.3 Troubleshooting (LMT)Contact the technical assistance center (TAC) to get support in isolating the fault. For suitable preparation save the error symptoms as described in “Collect Info for Assis-tance”. Log files need to be analyzed and specific measures must be taken which are out of the operator’s scope.
Managed Object Class / Hardware Type:
Cc
Event Type: processingErrorAlarm
Probable Cause: FileError
Severity: warning
154 DN70580522Issue 01A
Troubleshooting Node B
Id:0900d8058022b651Confidential
201016 - Non-fatal internal LVDS failure
103 201016 - Non-fatal internal LVDS failure
103.1 Failure Event Report
103.2 Error DescriptionA non-fatal hardware error has occurred (internal LVDS failure) in the reporting DRIC. The state of the card is changed accordingly (AVS is degraded). If the card is providing service (SBS is Providing Service), parts of the service could be lost and some of the cells get disabled.
The card is still working partly but should be replaced. If a redundant card is installed which is enabled, an operator-triggered switchover can be initiated from LMT.
103.3 Troubleshooting (LMT)1. If a redundant card is installed, perform a switch-over to this card. Afterwards, this
card will be active.To trigger a switch-over from the active to a redundant card installed, set the admin-istrative state of the reporting DRIC to shuttingDown. Use the TREE View window of the LMT or, alternatively, apply the Dric “Set administrativeState ShuttingDown” command to it.g NOTE
A switch-over to a redundant DRIC can only be triggered by setting the active DRIC’s AVS to shuttingDown. Setting the AVS to locked is not sufficient.Applying the Dric “Set administrativeState ShuttingDown” command is further-more only allowed if no cells would go down due to this operation.
2. Replace the defective card which used to be active before. Replacement must be done according to the “Replacing Node B Units” instructions.g NOTE
Replacing the formerly active card will lead to a scenario in which all services will be lost if there is not any redundant card installed.
Managed Object Class / Hardware Type:
Dric
Event Type: equipmentAlarm
Probable Cause: EquipmentMalfunction
Severity: minor
DN70580522 Issue 01A
155
Troubleshooting Node B 201017 - Digital input power level too high, but gainreduced
Id:0900d8058022b659Confidential
104 201017 - Digital input power level too high, but gain reduced
104.1 Failure Event Report
104.2 Error DescriptionThe CAT/RRH detected a digital input power level from the DRIC that has continuously been too high. In fact, the digital input power level has been more than 5 dB above the maximum output power of the CAT/RRH for more than 60 seconds.
A root cause for the occurrence of the “201017 – Digital input power level too high, but gain reduced” alarm may be the following: the congestion control parameters for the related cell are not configured sufficiently in the RNC’s database.
For more information about setting up congestion control in a specific cell, please refer to the WCDMA RAN Parameter Dictionary and the Admission Control radio resource management functional area description.
104.3 Troubleshooting (LMT)In order to solve this error, perform the following steps in the given order:1. Confirm that all relevant cables are connected properly.
2. Check the setting of the following parameters related to congestion control in the RNC database. The relevant parameters for the related cell of this Node B must be set to the following values:– Downlink congestion threshold < 90%– Downlink congestion hysteresis > 15%– Number of bearers that are switched/dropped in each step: more than one (1)– Bearer dropping has to be enabled
3. If the fault could not be cleared, the addressed card must be replaced. Replacement must be done according to the “Replacing Node B Units” manual, “Tasklist”.
Managed Object Class / Hardware Type:
Cat, Rrh
Event Type: equipmentAlarm
Probable Cause: ExcessiveTransmitterOutputPower
Severity: minor
!WARNING: Radiation from laser devices (EN 60825/IEC 60825).
Damage of health may occur.
To avoid damage to health, you must observe the regulations regarding protection against radiation from laser devices (EN 60825/IEC 60825). • You must always use dedicated laser-protective goggles. • Never look into open fiber-optic cable ends, as this may damage your eyes.
156 DN70580522Issue 01A
Troubleshooting Node B
Id:0900d8058022b65fConfidential
201018 - The LRU could not process a message from CC
105 201018 - The LRU could not process a message from CC
105.1 Failure Event Report
105.2 Error DescriptionA fatal software error has occurred: the addressed LRU indicates a messaging failure towards the CC.
After an unsuccessful automatic recovery by means of a reset, the reporting LRU was put out of service.
As a consequence, cells or calls could potentially be lost. The states of all affected managed objects change accordingly.
105.3 Troubleshooting (LMT)In order to solve this error, perform the following steps in the given order:1. Check the hardware compatibility of the configuration.
If necessary, replace the relevant card. Replacement must be done according to the “Replacing Node B Units” instructions.
2. Reset the relevant card or external module.Use the TREE View window of the LMT and apply the respective command, depending on the reporting managed object:CAT Cat “reset”CC Cc “reset”CHC Ch “reset”DRIC Dric “reset”DRX Drx “reset”REP Rep “reset”RET Ret “reset”RRH Rrh “reset”TMA Tma “reset”TRX Trx “reset”
3. Contact the technical assistance center (TAC) to get support in isolating the fault. For suitable preparation save the error symptoms as described in “Collect Info for Assistance”. Log files need to be analyzed and specific measures must be taken which are out of the operator’s scope.
Managed Object Class / Hardware Type:
Cc, Ch, Rep, Trx, Tma, Dric, Cat, Ret, Rrh, Drx
Event Type: processingErrorAlarm
Probable Cause: InvalidParameter
Severity: major (final), handled according to the Fault Escalation Strategy
DN70580522 Issue 01A
157
Troubleshooting Node B 201019 - Gain below threshold
Id:0900d8058022b665Confidential
106 201019 - Gain below threshold
106.1 Failure Event Report
106.2 Error DescriptionThe gain of the CAT/RRH falls below a certain threshold. The output power has been 3dB below the expected output power calculated from the digital input signal for more than a specified period of time.
As a consequence, the reporting CAT/RRH was put out of service. Cells or calls could potentially be lost. The states of all affected managed objects change accordingly.
106.3 Troubleshooting (LMT)Contact the technical assistance center (TAC) to get support in isolating the fault. For suitable preparation save the error symptoms as described in “Collect Info for Assis-tance”. Log files need to be analyzed and specific measures must be taken which are out of the operator’s scope.
Managed Object Class / Hardware Type:
Cat, Rrh
Event Type: equipmentAlarm
Probable Cause: SignalQualityEvaluationFault
Severity: major
158 DN70580522Issue 01A
Troubleshooting Node B
Id:0900d8058022b66dConfidential
201020 - Loss of single DRIF interface detected
107 201020 - Loss of single DRIF interface detected
107.1 Failure Event Report
107.2 Error DescriptionThe communiation to a specific CAT/RRH module over one CPRI-compliant DRIF inter-face was lost, whereas a second DRIF interface to this CAT/RRH exits and is still working.
The single DRIF loss may be caused by a missing cable connection, by hardware problems on the CAT/RRH-DRIF-interface side as well as on the DRIC side.
As a consequence, cells or calls could potentially be lost if the lost DRIF carried user plane data. Furthermore, the states of all affected managed objects change accordingly.
107.3 Troubleshooting (LMT)In order to solve this error, perform the following steps in the given order:1. Confirm that all relevant cables are connected properly.
2. If the fault could not be cleared, replace the defective card. Replacement must be done according to the “Replacing Node B Units” manual, “Tasklist”.
Managed Object Class / Hardware Type:
Dric
Event Type: equipmentAlarm
Probable Cause: LinkFailure
Severity: minor
!WARNING: Radiation from laser devices (EN 60825/IEC 60825).
Damage of health may occur.
To avoid damage to health, you must observe the regulations regarding protection against radiation from laser devices (EN 60825/IEC 60825). • You must always use dedicated laser-protective goggles. • Never look into open fiber-optic cable ends, as this may damage your eyes.
DN70580522 Issue 01A
159
Troubleshooting Node B 201022 - Alignment of file data has failed
Id:0900d8058022b673Confidential
108 201022 - Alignment of file data has failed
108.1 Failure Event Report
108.2 Error DescriptionAlignment of file data from the active to the standby CC failed.
The data to be aligned is not indispensable for redundancy in general. For example logging-, or PM-data can be affected.
The error should be reported to customer services. It is possible that a hardware or software error is the root of the problem.
108.3 Troubleshooting (LMT)Contact the technical assistance center (TAC) to get support in isolating the fault. For suitable preparation save the error symptoms as described in “Collect Info for Assis-tance”. Log files need to be analyzed and specific measures must be taken which are out of the operator’s scope.
Managed Object Class / Hardware Type:
Cc
Event Type: processingErrorAlarm
Probable Cause: FileError
Severity: minor, handled according to the Fault Escalation Strategy
160 DN70580522Issue 01A
Troubleshooting Node B
Id:0900d8058022b67bConfidential
201023 - Bad signal quality of single DRIF interface detected
109 201023 - Bad signal quality of single DRIF interface detected
109.1 Failure Event Report
109.2 Error DescriptionThe addressed CAT/RRH module detected that the signal quality on one DRIF will not ensure a reliable data transmission.
The following cases are possible: • Case 1: The DRIF to DRIC-N is affected and a second working DRIF connection to
DRIC-E exists. Therefore, CAT/RRH connects to DRIC-E. However, in this case cells and calls could potentially be lost.
• Case 2: The DRIF to DRIC-E is affected. This case has no direct impact for cells and calls until a switch over to DRIC-E occurs.
This alarm message may occur in conjunction with 201020 - Loss of single DRIF inter-face detected on DRIC-N.
The failure can be caused by one of the following:
• Failure to receive an expected response to a CORBA request within specified time limits.
• Indications of a connection failure from the communication stack, for example pointto-point protocol (PPP), internet protocol (IP), high level data link control protocol (HDLC), etc.
109.3 Troubleshooting (LMT)In order to solve this error, perform the following steps in the given order:1. Confirm that all relevant cables are connected properly.
2. If the fault could not be cleared, replace the defective card/external module.Replacement must be done according to the “Replacing Node B Units” manual, “Tasklist”.
Managed Object Class / Hardware Type:
Cat, Rrh
Event Type: equipmentAlarm
Probable Cause: LinkFailure
Severity: minor
!WARNING: Radiation from laser devices (EN 60825/IEC 60825).
Damage of health may occur.
To avoid damage to health, you must observe the regulations regarding protection against radiation from laser devices (EN 60825/IEC 60825). • You must always use dedicated laser-protective goggles. • Never look into open fiber-optic cable ends, as this may damage your eyes.
DN70580522 Issue 01A
161
Troubleshooting Node B 201023 - Bad signal quality of single DRIF interfacedetected
Id:0900d8058022b67bConfidential
3. If the replacement of the card/external module could not clear the fault, contact the technical assistance center (TAC) to get support in isolating the fault. For suitable preparation save the error symptoms as described in “Collect Info for Assistance”. Log files need to be analyzed and specific measures must be taken which are out of the operator’s scope.
162 DN70580522Issue 01A
Troubleshooting Node B
Id:0900d8058022b683Confidential
201024 - Bad signal quality of all DRIF interfaces de-tected
110 201024 - Bad signal quality of all DRIF inter-faces detected
110.1 Failure Event Report
110.2 Error DescriptionThe addressed CAT/RRH/DRX module detected that the signal quality on all DRIF will not ensure a reliable data transmission. After an unsuccessful automatic recovery (card reset), the CAT/RRH/DRX was put out of service. The states of the CAT/RRH/DRX (operational state, availability status, and alarm status) changed accordingly.
As a consequence, cells or calls could potentially be lost. The states of all affected managed objects change accordingly.
The failure can be caused by one of the following: • Failure to receive an expected response to a CORBA request within specified time
limits • Indications of a connection failure from the communication stack, for example
pointto-point protocol (PPP), internet protocol (IP), high level data link control protocol (HDLC), etc.
110.3 Troubleshooting (LMT)In order to solve this error, perform the following steps in the given order:1. Confirm that all relevant cables are connected properly.
2. If the fault could not be cleared, replace the defective card/external module.Replacement must be done according to the “Replacing Node B Units” manual, “Tasklist”.
3. If the replacement of the card/external module could not clear the fault, contact the technical assistance center (TAC) to get support in isolating the fault. For suitable preparation save the error symptoms as described in “Collect Info for Assistance”.
Managed Object Class / Hardware Type:
Cat, Rrh, Drx
Event Type: equipmentAlarm
Probable Cause: LinkFailure
Severity: major (final), handled according to the Fault Escalation Strategy
!WARNING: Radiation from laser devices (EN 60825/IEC 60825).
Damage of health may occur.
To avoid damage to health, you must observe the regulations regarding protection against radiation from laser devices (EN 60825/IEC 60825). • You must always use dedicated laser-protective goggles. • Never look into open fiber-optic cable ends, as this may damage your eyes.
DN70580522 Issue 01A
163
Troubleshooting Node B 201024 - Bad signal quality of all DRIF interfaces de-tected
Id:0900d8058022b683Confidential
Log files need to be analyzed and specific measures must be taken which are out of the operator’s scope.
164 DN70580522Issue 01A
Troubleshooting Node B
Id:0900d8058022b68bConfidential
201025 - PID could not be read or is corrupted
111 201025 - PID could not be read or is corrupted
111.1 Failure Event Report
111.2 Error DescriptionA hardware error has occurred! The PID of the addressed LRU could not be read or is corrupted. Basic operation of the affected LRU is not possible.
The information contained in the PID is essential for the operation of the LRU. Therefore, the reporting LRU will fail.
As a consequence, cells or calls could potentially be lost. The states of all affected managed objects change accordingly.
Report this error to customer service. The PID of the failed LRU has to be updated.
111.3 Troubleshooting (LMT)Carrying out the following measures will help to solve this error:1. Replace the addressed card. Replacement must be done according to the “Replac-
ing Node B Units” manual, “Tasklist”.However, if OEM parts are affected, proceed according to the OEM vendor’s description.
2. If the replacement of the card could not clear the fault, contact the technical assis-tance center (TAC) to get support in isolating the fault. For suitable preparation save the error symptoms as described in “Collect Info for Assistance”. Log files need to be analyzed and specific measures must be taken which are out of the operator’s scope.
Managed Object Class / Hardware Type:
*
Event Type: equipmentAlarm
Probable Cause: EquipmentFailure
Severity: major (final), handled according to the Fault Escalation Strategy
DN70580522 Issue 01A
165
Troubleshooting Node B 201026 - LRU sent illegal parameter
Id:0900d8058022b693Confidential
112 201026 - LRU sent illegal parameter
112.1 Failure Event Report
112.2 Error DescriptionThe following fatal software error has occurred: the addressed LRU sent an illegal parameter.
After an unsuccessful automatic recovery by means of a reset, the reporting LRU was put of of service.
As a result of this failure, cells or calls could potentially be lost. Furthermore, the states of all affected managed objects change accordingly.
As a matter of principle, this error should always be reported to customer service.
Manual recovery can be applied by an operator-triggered reset of the addressed card from the LMT.
112.3 Troubleshooting (LMT)In order to solve this error, perform the following steps in the given order:1. Reset the addressed card.2. If the manual reset has not helped to cease the alarm, check the hardware compat-
ibility of the configuration.3. If the measures taken above have not been successful, contact the technical assis-
tance center (TAC) to get support in isolating the fault. For suitable preparation save the error symptoms as described in “Collect Info for Assistance”. Log files need to be analyzed and specific measures must be taken which are out of the operator’s scope.
Managed Object Class / Hardware Type:
*
Event Type: processingErrorAlarm
Probable Cause: InvalidParameter
Severity: major (final), handled according to the Fault Escalation Strategy
166 DN70580522Issue 01A
Troubleshooting Node B
Id:0900d8058022b699Confidential
201027 - LRU could not process a message from CC containing data from DB
113 201027 - LRU could not process a message from CC containing data from DB
113.1 Failure Event Report
113.2 Error DescriptionA fatal error has occurred: the reporting LRU could not process a message from the core controller (CC) containing data from the Node B’s database (DB).
This alarm may be caused by one of the following: • Wrong database • A database attribute which has been changed via Itf-B from the LMT.
As a consequence of this failure, service may be affected.
The database should be verified. Manual recovery could be applied by an operator-trig-gered reset of the reporting object from the LMT.
113.3 Troubleshooting (LMT)The following measures must be taken in the given order to solve this error:
1 Reset the reporting card by means of the following procedure:
1. Lock the card/module.Use the TREE View window of the LMT and apply the respective command, depending on the reporting managed object:CAT Cat “Set administrativeState Locked”CHC Ch “Set administrativeState Locked”DRIC Dric “Set administrativeState Locked”DRX Drx “Set administrativeState Locked”REP Rep “Set administrativeState Locked”RRH Rrh “Set administrativeState Locked”TRX Trx “Set administrativeState Locked”
2. Reset the relevant card or external module.Use the TREE View window of the LMT and apply the respective command, depending on the reporting managed object:CAT Cat “reset”CHC Ch “reset”DRIC Dric “reset”DRX Drx “reset”REP Rep “reset”RRH Rrh “reset”
Managed Object Class / Hardware Type:
Ch, Rep, Trx, Dric, Cat, Rrh, Drx
Event Type: processingErrorAlarm
Probable Cause: InvalidParameter
Severity: major
DN70580522 Issue 01A
167
Troubleshooting Node B 201027 - LRU could not process a message from CCcontaining data from DB
Id:0900d8058022b699Confidential
TRX Trx “reset”
2 If the manual reset did not help to solve this error, check the Node B’s database. The DB check must be performed according to the OGL:Node B DB Editing Guide.
3 Change the Node B’s DB. The DB change must be performed according to the OGL:Node B DB Editing Guide.
4 If the measures taken above have not been successful, contact the technical assis-tance center (TAC) to get support in isolating the fault. For suitable preparation save the error symptoms as described in ’Collect Info for Assistance’. Log files need to be analyzed and specific measures must be taken which are out of the operator’s scope.
168 DN70580522Issue 01A
Troubleshooting Node B
Id:0900d8058022b69fConfidential
201028 - Node B system clock hardware failure
114 201028 - Node B system clock hardware failure
114.1 Failure Event Report
114.2 Error DescriptionThis error is caused by a fatal HW failure of the active core controller’s (CC) clock pro-cessing unit. This failure may lead to impacts on the air interface’s synchronization.
If the clock processing failure occurs simultaneously with the 202506 - Node B system clock in holdover mode alarm, stable Node B operation may not be possible any longer.
As a consequence, cells or calls could be lost. The states (operational state and avail-ability status) of all affected managed objects change accordingly.
The card should be replaced. Furthermore, manual recovery could be applied by an operator-triggered reset of the CC from the LMT. If a standby CC is installed, a switch over to this CC can be initiated, too.
114.3 Troubleshooting (LMT)Perform the following steps in the given order to solve this alarm:1. Reset the defective core controller.
Use the TREE View window of the LMT and apply the Cc “reset” command to the (defective) active core controller (CC) MOI).
2. If a standby CC is installed, perform a switch over from the defective active CC to the standby CC.Use the TREE View window of the LMT and apply the Cc “redundancySwitch” command to the active CC.
3. Replace the defective CC. Replacement must be done according to the “Replacing Node B Units” instructions.
Managed Object Class / Hardware Type:
NodeBFddE
Event Type: equipmentAlarm
Probable Cause: EquipmentMalfunction
Severity: major
DN70580522 Issue 01A
169
Troubleshooting Node B 201029 - MEF blocked
Id:0900d8058022b6a7Confidential
115 201029 - MEF blocked
115.1 Failure Event Report
115.2 Error DescriptionThe membrane filter (MEF) is polluted. Therefore, the MEF’s lifetime will run out.
The 200920 - High temperature of PA alarm has been output before. This alarm indi-cates a high temperature scenario in at least one PA installed in the Node B.
The MEF has to be exchanged within the next 2 weeks.
A further increase of the MEF’s pollution may lead to a severe defect. A heavily-polluted MEF can cause the following alarms: • 200921 - Over temperature of PA • 200986 - Temperature out of range in upper direction • 200995 - High Temperature Limit (Ht3) reached • 200996 - Critical Temperature Limit (Ht4) reached • 201035 - MEF completely blocked
115.3 Troubleshooting (LMT)Replace the MEF during the next two (2) weeks after occurrence of this alarm. Replace-ment must be done according to the “Replacing Node B Units”, manual, “Tasklist”.
Replacing the MEF will assure a sufficient air flow and therefore cooling of the Node B.
Managed Object Class / Hardware Type:
BaseRack
Event Type: equipmentAlarm
Probable Cause: EquipmentMalfunction
Severity: minor
170 DN70580522Issue 01A
Troubleshooting Node B
Id:0900d8058022b6afConfidential
201030 - Invalid hardware capacity licensing value
116 201030 - Invalid hardware capacity licensing value
116.1 Failure Event Report
116.2 Error DescriptionThe hardware capacity licensing value read from the reporting card is invalid.
116.3 Troubleshooting (LMT)Perform the following steps in the given order to solve this error:1. Replace the reporting card by a licensed card. Replacement must be done accord-
ing to the “Replacing Node B Units” manual, “Tasklist”.2. If the replacement of the card could not clear the fault, contact the technical assis-
tance center (TAC) to get support in isolating the fault. For suitable preparation save the error symptoms as described in “Collect Info for Assistance”. Log files need to be analyzed and specific measures must be taken which are out of the operator’s scope.
Managed Object Class / Hardware Type:
Cat, Cc, Ch, Dric
Event Type: processingErrorAlarm
Probable Cause: CorruptData
Severity: warning
DN70580522 Issue 01A
171
Troubleshooting Node B 201031 - Wrong combination of licensed cards
Id:0900d8058022b6b7Confidential
117 201031 - Wrong combination of licensed cards
117.1 Failure Event Report
117.2 Error DescriptionThe combination of hardware capacity licensing values is invalid. This error might be caused by using more cards that carry a restricted license than supported by the licens-ing terms and conditions.
117.3 Troubleshooting (LMT)Perform the following steps in the given order to solve this error:1. Check the hardware compatibility of the configuration.2. If the first step could not clear the fault, contact the technical assistance center
(TAC) to get support in isolating the fault. For suitable preparation save the error symptoms as described in “Collect Info for Assistance”. Log files need to be analyzed and specific measures must be taken which are out of the operator’s scope.
Managed Object Class / Hardware Type:
NodeBFddE
Event Type: processingErrorAlarm
Probable Cause: ConfigurationOrCustomizationError
Severity: minor
172 DN70580522Issue 01A
Troubleshooting Node B
Id:0900d8058022b6c0Confidential
201032 - Not all cells are licensed
118 201032 - Not all cells are licensed
118.1 Failure Event Report
118.2 Error DescriptionThe contracted hardware capacity licenses for UTRAN cells do not cover all cells con-figured in the Node B’s database. Those cells which are not licensed remain disabled after Node B’s start-up.
118.3 Troubleshooting (LMT)Carrying out the following steps in the given order will help to solve this alarm:1. Check the compatibility of the current configuration.2. Check the Node B’s database (DB), using the mibCheck or mibCheckWin tool deliv-
ered with the Node B’s software. The DB check must be performed according to the “Node B Database Editing Guide”.
3. Change the Node B’s DB in such a way that only the licensed number of UTRAN cells is configured. The DB change must be performed according to the “Node B Database Editing Guide”.
Managed Object Class / Hardware Type:
NodeBFddE
Event Type: processingErrorAlarm
Probable Cause: ConfigurationOrCustomizationError
Severity: minor
DN70580522 Issue 01A
173
Troubleshooting Node B 201033 - PID could not be read or is corrupted - non-fatal
Id:0900d8058022b6c8Confidential
119 201033 - PID could not be read or is corrupted - non-fatal
119.1 Failure Event Report
119.2 Error DescriptionA hardware error has occurred! The PID of the addressed LRU could not be read or is corrupted. Basic operation of the affected LRU is possible without the information con-tained in the PID.
Service is not affected.
Report this error to customer service. The PID of the failed LRU has to be updated.
119.3 Troubleshooting (LMT)Carrying out the following measures will help to solve this error:1. Replace the addressed card.
– Replacement must be done according to the “Replacing Node B Units” manual, “Tasklist”.
– However, if OEM parts are affected, proceed according to the OEM vendor’s description.
2. If the replacement of the card could not clear the fault, contact the technical assis-tance center (TAC) to get support in isolating the fault. For suitable preparation save the error symptoms as described in “Collect Info for Assistance”. Log files need to be analyzed and specific measures must be taken which are out of the operator’s scope.
Managed Object Class / Hardware Type:
*
Event Type: equipmentAlarm
Probable Cause: EquipmentFailure
Severity: minor
174 DN70580522Issue 01A
Troubleshooting Node B
Id:0900d8058022b6d0Confidential
201034 - Booster’s Fan unit failed
120 201034 - Booster’s Fan unit failed
120.1 Failure Event Report
120.2 Error DescriptionThe fan unit of the reporting booster is defective. This situation leads to a lack of air cir-culation in the affected Node B. A failure of components which are sensitive to heat may exist.
Caused by the insufficient air circulation in the Node B, related temperature alarms may be reported by the addressed booster. The following alarms may therefore occur in con-junction with the ’201034 - Booster’s Fan unit failed’ alarm: • 200920 - High temperature of PA • 200921 - Over temperature of PA
120.3 Troubleshooting (LMT)
g NOTEThe defective fan unit(s) are recommended to be exchanged within the next 24 hours!
Replace the defective fan unit of the reporting booster within the next 24 hours. Replace-ment must be done according to the “Replacing Node B Units” manual, “Tasklist”.
Managed Object Class / Hardware Type:
Booster
Event Type: environmentalAlarm
Probable Cause: FanFailure
Severity: major
!DANGER: Circulating rotor of the fan module!
Damage to health may occur when fingers are cut.
When pulling out the fan module, the rotor may still rotate for a few seconds. To prevent serious injuries, watch your fingers.
DN70580522 Issue 01A
175
Troubleshooting Node B 201035 - MEF completely blocked
Id:0900d8058022b6d6Confidential
121 201035 - MEF completely blocked
121.1 Failure Event Report
121.2 Error DescriptionThe membrane filter (MEF) is heavily polluted. Therefore, the MEF’s lifetime has run out.
The 200921 - Over temperature of PA alarm has been output before. This alarm indi-cates an over temperature scenario in at least one PA installed in the Node B.
Exchange the defective MEF immediately. Otherwise a severe hardware damage can occur.
A defective MEF can cause the following alarms: • 200986 - Temperature out of range in upper direction • 200995 - High Temperature Limit (Ht3) reached • 200996 - Critical Temperature Limit (Ht4) reached
121.3 Troubleshooting (LMT)Take the following measures to clear the fault which cause this alarm:1. Replace the MEF immediately.
Replacement must be done according to the “Replacing Node B Units” instructions.Replacing the defective MEF will assure a sufficient air flow and therefore cooling of the Node B.
2. As the 200921 - Over temperature of PA alarm is a fatal alarm (severity: major), all PAs which report this alarm have to be reset manually via LMT.Use the TREE View window of the LMT and apply the respective reset action com-mand(s) to the reporting PA(s).
Managed Object Class / Hardware Type:
BaseRack
Event Type: equipmentAlarm
Probable Cause: EquipmentMalfunction
Severity: critical
176 DN70580522Issue 01A
Troubleshooting Node B
Id:0900d8058022b6deConfidential
201036 - RRHs unable to establish communication links with the expected number of PSRs
122 201036 - RRHs unable to establish communi-cation links with the expected number of PSRs
122.1 Failure Event Report
122.2 Error DescriptionRemote radio heads (RRHs) of the reporting Node B cannot establish communication links with the expected number of power supplies for the RRHs (PSRs).
The problem indicated by this alarm may occur in either of the following situations: • After Node B startup, not all configured PSRs managed to establish a communica-
tion link with a connected RRH within a specified period of time.Besides RRH and PSR hardware defects and wrong cable connections, this alarm can occur when the number of PSRs configured in the system is wrong.
• After breakdown of a communication link, a PSR failed to reconnect itself to an RRH within a specified period of time.The breakdown of a communication link may be caused by the following:– RRH or PSR hardware defect– Broken cable connection– Preceding reset of the related RRH
If no communication link between RRH and PSR exists, no PSR alarms can be reported by the Node B.
122.3 Troubleshooting (LMT)Take the following measures to clear the fault cause and, thus, the alarm:1. Confirm that all cables are connected properly.2. Replace the defective PSRs. Replacement must be done according to the “Replac-
ing Node B Units” manual, “Tasklist”.3. If the alarm has not ceased yet, check in the Node B’s database whether the number
of PSRs configured in the system is wrong.– Check the Node B database. Use the mibCheck or mibCheckWin tool delivered
with the Node B’s software. Proceed according to the “Node B Database Editing Guide”.
– If necessary, change the running database. Edit the database according to the “Node B Database Editing Guide”.
Managed Object Class / Hardware Type:
NodeBFddE
Event Type: equipmentAlarm
Probable Cause: EquipmentFailure
Severity: minor
DN70580522 Issue 01A
177
Troubleshooting Node B 201037 - ALD unspecified error
Id:0900d8058022b6e6Confidential
123 201037 - ALD unspecified error
123.1 Failure Event Report
123.2 Error DescriptionAn unspecified error occurred in the reporting antenna line device (ALD), i.e. RET module or TMA. Due to this error, the addressed antenna line device is disabled.
123.3 Troubleshooting (LMT)
Perform the following steps in the given order to solve this error:1. Replace the defective antenna line device:
– RET replacement: Since both the RET module and the antenna are OEM prod-ucts, replacement must be done according to the OEM vendor’s description.
– TMA replacement: Replacement must be done according to the “Replacing Node B Units” manual, “Tasklist”.
2. If the card replacement did not clear the fault, contact the technical assistance center (TAC) to get support in isolating the fault. For suitable preparation save the error symptoms as described in “Collect Info for Assistance”. Log files need to be analyzed and specific measures must be taken which are out of the operator’s scope.
Managed Object Class / Hardware Type:
Ret, Tma
Event Type: equipmentAlarm
Probable Cause: ExternalIFDeviceProblem
Severity: minor (final), handled according to the Fault Escalation Strategy
!DANGER: Uncontrolled emission of microwave radiation.
Damage of health may occur.
To avoid the danger of an uncontrolled emission of microwave radiation, switch off the breakers for the related LPAs/CATs before replacing antenna cables, antennas, RET, or DUAMCO.
178 DN70580522Issue 01A
Troubleshooting Node B
Id:0900d8058022b6eaConfidential
201038 - Resource conflict between CP and OAM
124 201038 - Resource conflict between CP and OAM
124.1 Failure Event Report
124.2 Error DescriptionThe CP rejected a request of the RNC, such as a radio link setup request, because the necessary resources are currently allocated by OAM, for instance channels for orthog-onal channel noise simulator (OCNS). These resources may be channelization codes or code trees occupied by DLLG or OCNS, issued by the startModulatedSignalTransmis-sion command.
The required resources have to be freed, releasing the OCNS channels, for example, before the RNC’s request can be processed.
This alarm is cleared as soon as all DLLG and OCNS channels are stopped on the affected cell.
124.3 Troubleshooting (LMT)To solve this problem, free the occupied resources of the reporting cell (LocalCellE MOI) by completely stopping the DLLG or OCNS channels. Use the TREE View window of the LMT and apply the endModulatedSignalTransmission action command to the LocalCellE object the occupied resources are assigned to.
This will clear the alarm and free the resources allocated by OAM. RNC requests can now be serviced again.
To avoid such collisions in the future, an adjustment of the channelization codes used for OCNS may be necessary.
Managed Object Class / Hardware Type:
LocalCellE
Event Type: processingErrorAlarm
Probable Cause: UnderlyingResourceUnavailable
Severity: minor
DN70580522 Issue 01A
179
Troubleshooting Node B 201039 - Inconsistency between hardware license andconfiguration
Id:0900d8058022b6f2Confidential
125 201039 - Inconsistency between hardware license and configuration
125.1 Failure Event Report
125.2 Error DescriptionThe hardware capacity license of the reporting LRU is not consistent with the current configuration. This error may be caused by using an LRU equipped with an insufficient license.
As a result, the addressed LRU is put out of service. Additionally, all cells related to this LRU remain disabled after startup.
125.3 Troubleshooting (LMT)To solve this error, perform the following steps in the order provided:1. Check the hardware compatibility of the Node B.2. Update the addressed LRU’s hardware capacity to the required value.3. If the first steps could not clear the fault, contact the technical assistance center
(TAC) to get support in isolating the fault. For suitable preparation save the error symptoms as described in “Collect Info for Assistance”. Log files need to be analyzed and specific measures must be taken which are out of the operator’s scope.
Managed Object Class / Hardware Type:
Cat, Ret, Rrh
Event Type: processingErrorAlarm
Probable Cause: ConfigurationOrCustomizationError
Severity: major
180 DN70580522Issue 01A
Troubleshooting Node B
Id:0900d8058022b6faConfidential
201040 - Wrong cabling of LRU detected
126 201040 - Wrong cabling of LRU detected
126.1 Failure Event Report
126.2 Error DescriptionThe reporting LRU was not cabled correctly according to the installation manual of the Node B. As a result, the addressed LRU has been put out of service. All cells related to this LRU remain disabled.
126.3 Troubleshooting (LMT)Perform the following steps in the order provided to solve this error: • For rack-mounted LRUs:
Check for the LRU’s correct position in the Node B’s rack. • Otherwise, confirm that cables are connected correctly to the addressed LRU. In the
event of wrong cabling, connect the cables correctly to the LRU. Proceed according to the installation manual (IMN) of the relevant Node B.– For NB-440 or NB-880, refer to the Installing NB-440/NB-880.– For NB-441 or NB-881, refer to the Installing NB-441/NB-881.– For NB-420 or NB-860, refer to the Installing NB-420/NB-860.– For NB-861, refer to to the Installing NB-861.– For NB-341, refer to the Installing NB-341.– For Radio Server Slider Unit RSSU-380, refer to the Installing RSSU-380.– For Radio Server RS-381, refer to the Installing RS-381.– For Radio Server RS-880, refer to the Installing RS-880.
Managed Object Class / Hardware Type:
Cat, Drx, Rrh
Event Type: processingErrorAlarm
Probable Cause: ConfigurationOrCustomizationError
Severity: major
DN70580522 Issue 01A
181
Troubleshooting Node B 201041 - Test channels have been lost
Id:0900d8058022b6feConfidential
127 201041 - Test channels have been lost
127.1 Failure Event Report
127.2 Error DescriptionUsing the startModulatedSignalTransmission or staModSTx actions at the LMT or RC, respectively, operators can start tests such as modulated signal transmission (MST), downlink load generation (DLLG), or orthogonal channel noise simulation (OCNS).
This alarm indicates that one or several test channels for MST, DLLG, or OCNS have been lost. The loss of test channels may be caused by one of the following: • Test channels have been lost due to a necessary channel card reconfiguration.The
reconfiguration of the CHC can be caused by a reset of the CHC or by a failure of the CHC which in turn led to a reset.
• The RNC has deleted a cell on which test channels were set up. • A cell on which test channels were set up has been disabled. Among other causes,
disabling the cell may have been caused by the following:– Hardware problem– Shutdown operation by the user– Lock operation by the user
• The RNC sent request to the reporting Node B, such as an NBAP: RADIO LINK SETUP REQUEST message. The RNC thus required resources which had previ-ously been allocated by one or several test channels.
As a consequence of the failure reported by this alarm, all test channels on the affected cell (LocalCellE MOI) have been stopped. Furthermore, this ’201041 - Test channels have been lost’ alarm has to be cleared before any new test channel can be set up again on the reporting cell (LocalCellE MOI).
127.3 Troubleshooting (LMT)To clear this alarm, free the resources occupied by the test channels. Use the TREE View window of the LMT and apply the endModulatedSignalTransmission action command to the LocalCellE object in which the test channels have been configured.
As a consequence, all test channels in the reporting cell (LocalCellE MOI) will be stopped.
Managed Object Class / Hardware Type:
LocalCellE
Event Type: processingErrorAlarm
Probable Cause: UnderlyingResourceUnavailable
Severity: minor
182 DN70580522Issue 01A
Troubleshooting Node B
Id:0900d8058022b706Confidential
201042 - Incompatible Firmware
128 201042 - Incompatible Firmware
128.1 Failure Event Report
128.2 Error DescriptionThe mounted card does not fulfill the Node B's configuration requirements. In other words, the reporting card’s firmware (FW) does not fit to one or several features, for example smart cell configuration, operated in this Node B.
128.3 Troubleshooting (LMT)In order to solve this error, perform the following steps in the given order:1. Check the hardware compatibility of the configuration.2. Download a valid firmware to the specified card.
The update of the firmware must be done according to the “Replacing Node B Units” manual, “Tasklist”.
3. If the error has not ceased yet, contact the technical assistance center (TAC) to get support in isolating the fault. For suitable preparation save the error symptoms as described in “Collect Info for Assistance”. Log files need to be analyzed and specific measures must be taken which are out of the operator’s scope.
Managed Object Class / Hardware Type:
Cat, Duamco, Rrh
Event Type: processingErrorAlarm
Probable Cause: ConfigurationOrCustomizationError
Severity: major
DN70580522 Issue 01A
183
Troubleshooting Node B 201043 - Missing software image
Id:0900d8058022b70cConfidential
129 201043 - Missing software image
129.1 Failure Event Report
129.2 Error DescriptionThe ’201043 - Missing software image’ alarm indicates that the mounted card, which reports this alarm, could not start up. The reporting card failed to start up because a software image (SWI) is missing.Due to the missing SWI, the automatic upgrade config-uration procedure either has failed or was not started at all. The upgrade configuration procedure ensures that missing SWIs are downloaded to the Node B and added to the currently running smart software package without resetting the Node B.
129.3 Troubleshooting (LMT)In order to solve this error, perform the following steps in the given order:1. Start the update configuration procedure manually.
Use the TREE View window of the LMT and apply the Osu “updateConfiguration” command to the relevant Osu instance in the reporting Node B.
2. If the error has not ceased yet, contact the technical assistance center (TAC) to get support in isolating the fault. For suitable preparation save the error symptoms as described in “Collect Info for Assistance”. Log files need to be analyzed and specific measures must be taken which are out of the operator’s scope.
Managed Object Class / Hardware Type:
Cc, Ch, Dric, Rep, Trx
Event Type: processingErrorAlarm
Probable Cause: SoftwareDownloadFailure
Severity: major
184 DN70580522Issue 01A
Troubleshooting Node B
Id:0900d8058022b714Confidential
201044 - Non fatal configuration failure
130 201044 - Non fatal configuration failure
130.1 Failure Event Report
130.2 Error DescriptionThe addressed DUAMCO does not support a RET module in the current Node B config-uration. This mismatch is caused by one of the following: • If the Node B configuration does not contain a RET module, the DIP switch 6 is set
to ON position by accident. • Otherwise, if a RET module is installed in the Node B configuration and the Node B’s
DB contains a RET MO, the DUAMCO has to be replaced.
130.3 Troubleshooting (LMT)In order to solve this error, perform the following steps in the given order:1. If RET support is not required for the suspected Node B, switch OFF the DIP
switch 6.☞ For information about the DUAMCO’s DIP switches, refer to the “Node B
Cards/Modules Hardware Description”.2. If a RET module is installed and RET support is required for the suspected Node B,
replace the reporting DUAMCO by another type which is capable of supporting the RET module in the given configuration.Replacement of the DUAMCO must be done according to the “Replacing Node B Units” manual, “Tasklist”.
3. If the error has not ceased yet, contact the technical assistance center (TAC) to get support in isolating the fault. For suitable preparation save the error symptoms as described in “Collect Info for Assistance”. Log files need to be analyzed and specific measures must be taken which are out of the operator’s scope.
Managed Object Class / Hardware Type:
Duamco
Event Type: processingErrorAlarm
Probable Cause: ConfigurationOrCustomizationError
Severity: minor
DN70580522 Issue 01A
185
Troubleshooting Node B 201045 - Fatal hardware error
Id:0900d8058022b71aConfidential
131 201045 - Fatal hardware error
131.1 Failure Event Report
131.2 Error DescriptionThis alarm indicates the occurrence of a fatal hardware failure in the reporting Node B. The actual details of the hardware failure are provided in the additional text field of the alarm.
Users at the LMT: To obtain information in the alarm’s additional text field, use the ALARM View window of the LMT:1. Click on the “Alarm View” button or use the shortcut key Ctrl + A .2. Concentrate on the ’Additional Text’ column.
Users at the RC: To obtain information in the alarm’s additional text field, use the Alarm Monitoring application of the Radio Commander:1. Select and open the icon “Alarm Monitoring” in the Application Launcher window
(double left-click).2. Concentrate on the ’Additional Text’ column
If “RAM parity error at the ATM switching hardware” is displayed in the additional text field, the error occurred due to a defective RAM mounted on the reporting core control-ler.
131.3 Troubleshooting (LMT)If this alarm occurred due to the RAM parity error at the ATM switching hardware, replace the defective core controller. Replacement must be done according to the “Replacing Node B Units” instructions.
Perform the following tasks in the given order to solve this error:1. First, reset the addressed card.
Use the TREE View window of the LMT or, alternatively, apply the Cc “reset” command to the addressed card.
2. If the fault cannot be cleared by the reset, replace the addressed card.Replacement must be done according to the “Replacing Node B Units” instructions.
3. If the card replacement has not cleared the fault, either, contact the technical assis-tance center (TAC) to get support in isolating the fault. For suitable preparation save the error symptoms as described in ’Collect Info for Assistance’. Log files need to be analyzed and specific measures must be taken which are out of the operator’s scope.
Managed Object Class / Hardware Type:
Cc
Event Type: equipmentAlarm
Probable Cause: EquipmentFailure
Severity: critical
186 DN70580522Issue 01A
Troubleshooting Node B
Id:0900d8058022b720Confidential
201046 - No ATM connection for OAM Autoconfigura-tion
132 201046 - No ATM connection for OAM Auto-configuration
132.1 Failure Event Report
132.2 Error DescriptionWhile executing the Node B OAM auto configuration, the following failure occurred: incorrect configuration of the default or dedicated transport path for VCs (VcTTP managed object) used for O&M and/or FTP (usedByAttribute = “ftpOAndMCommand”).
The Node B has restarted a predefined number of times to solve the misconfiguration before finally raising this alarm. The detailed failure cause has been logged in the Node B’s log file.
132.3 Troubleshooting (LMT)Taking the following steps will help to clear the failure cause which led to this alarm:1. Check for alarms of managed objects on the physical or ATM layer, which are used
for the “ftpOAndMCommand” connection. These alarms may indicate the failure cause.Open the ALARM VIEW window of the LMT by either clicking on the “Alarm View” button or using the shortcut key Ctrl + A .VcTTP alarms in question:– 202072 – Alarm Indication Signal on an ATM VC– 202073 – Remote Defect Indication on an ATM VC– 202074 – SSCOP Failure Indication on an ATM VC used by ALCAP or NBAP– 202077 – ALCAP PVC Out Of Service IndicationVpTTP alarms in question:– 202075 – Alarm Indication Signal on an ATM VP– 202076 – Remote Defect Indication on an ATM VPE1TTP and J1TTP alarms in question:– 202056 – Loss Of Signal on Physical Link– 202057 – Loss Of Frame on Physical Link– 202058 – Loss Of Cell Delineation on Physical Link– 202059 – Alarm Indication Signal on Physical Link– 202060 – Remote Alarm Indication on Physical Link– 202061 – Loss Of MultiFrame Alarm Indication on E1 Physical Link (E1TTP
only)– 202098 – CRC4 not used by FE reported on E1TTP (E1TTP only)
Managed Object Class / Hardware Type:
Cc
Event Type: communicationsAlarm
Probable Cause: ConnectionEstablishmentError
Severity: Major
DN70580522 Issue 01A
187
Troubleshooting Node B 201046 - No ATM connection for OAM Autoconfigura-tion
Id:0900d8058022b720Confidential
Stm1TP alarms in question:– 202056 – Loss Of Signal on Physical Link– 202057 – Loss Of Frame on Physical Link– 202058 – Loss Of Cell Delineation on Physical Link– 202062 – Line Alarm Indication Signal Indication on STM1 Physical Link– 202063 – Line Remote Defect Indication on STM1 Physical Link– 202064 – Path Loss of Pointer Indication on STM1 Physical Link– 202065 – Path Alarm Indication Signal on STM1 Physical Link– 202066 – Path Remote Defect Indication on STM1 Physical Link– 202068 – Signal Label Mismatch Indication on STM1 Physical Link– 202070 – Signal Degrade Indication on STM1 Physical Link– 202071 – Excessive Bit Error Rate Indication on STM1 Physical Link
2. Contact the technical assistance center (TAC) to get support in isolating the fault. For suitable preparation save the error symptoms as described in “Collect Info for Assistance”. Log files need to be analyzed and specific measures must be taken which are out of the operator’s scope.
188 DN70580522Issue 01A
Troubleshooting Node B
Id:0900d80580619b47Confidential
201047 - Fatal BB software failure
133 201047 - Fatal BB software failure
133.1 Failure Event Report
133.2 Error DescriptionA fatal software failure occurred in the reporting baseband (BB) card.
After an unsuccessful automatic recovery by means of a reset, the reporting BB card was put out of service.
As a consequence, cells (LocalCellE instances) or calls could potentially be lost. The states of all affected managed objects change accordingly.
133.3 Troubleshooting (LMT)Take the following measures to clear the fault which had led to this alarm:1. Contact the technical assistance center (TAC) to get support in isolating the fault.
For suitable preparation save the error symptoms as described in “Collect Info for Assistance”. Log files need to be analyzed and specific measures must be taken which are out of the operator’s scope.
2. As a temporary solution, reset the defective baseband (BB) card again.Resetting the defective equipment may possibly put it into operation again.To reset the card, use the TREE View window of the LMT and apply the following action command, depending in the reporting card:CHC Ch “Reset”DRIC Dric “Reset”REP Rep “Reset”TRX Trx “Reset”
Managed Object Class / Hardware Type:
Ch, Dric, Rep, Trx
Event Type: processingErrorAlarm
Probable Cause: SoftwareError
Severity: major (final), handled according to the Fault Escalation Strategy
DN70580522 Issue 01A
189
Troubleshooting Node B 201048 - Non-fatal BB software failure
Id:0900d8058022b72cConfidential
134 201048 - Non-fatal BB software failure
134.1 Failure Event Report
134.2 Error DescriptionA non-fatal software failure occurred in the reporting baseband (BB) card. The BB card is still operational, but possibly with reduced performance.
As a consequence of the failure which led to this alarm, the Node B may be degraded in its performance.
134.3 Troubleshooting (LMT)Contact the technical assistance center (TAC) to get support in isolating the fault. For suitable preparation save the error symptoms as described in “Collect Info for Assis-tance”. Log files need to be analyzed and specific measures must be taken which are out of the operator’s scope.
Managed Object Class / Hardware Type:
Ch, Rep, Trx, Dric
Event Type: processingErrorAlarm
Probable Cause: SoftwareError
Severity: warning
190 DN70580522Issue 01A
Troubleshooting Node B
Id:0900d8058022b732Confidential
201049 - Non-fatal DSP failure
135 201049 - Non-fatal DSP failure
135.1 Failure Event Report
135.2 Error DescriptionA non-fatal digital signal processor (DSP) failure occurred in the reporting baseband (BB) card. The BB card is still operational, but possibly with reduced performance.
As a consequence of the BB card’s DSP failure, the Node B may be degraded in its per-formance.
135.3 Troubleshooting (LMT)Contact the technical assistance center (TAC) to get support in isolating the fault. For suitable preparation save the error symptoms as described in “Collect Info for Assis-tance”. Log files need to be analyzed and specific measures must be taken which are out of the operator’s scope.
Managed Object Class / Hardware Type:
Ch, Rep, Trx, Dric
Event Type: processingErrorAlarm
Probable Cause: SoftwareError
Severity: warning
DN70580522 Issue 01A
191
Troubleshooting Node B 201050 - Major hardware failure
Id:0900d8058022b738Confidential
136 201050 - Major hardware failure
136.1 Failure Event Report
136.2 Error DescriptionThis alarm is for future use. In the current release, this alarm should not be output at all.
136.3 Troubleshooting (LMT)Contact the technical assistance center (TAC) to get support in isolating the fault. For suitable preparation save the error symptoms as described in “Collect Info for Assis-tance”. Log files need to be analyzed and specific measures must be taken which are out of the operator’s scope.
Managed Object Class / Hardware Type:
Cc
Event Type: equipmentAlarm
Probable Cause: EquipmentFailure
Severity: major
192 DN70580522Issue 01A
Troubleshooting Node B
Id:0900d8058022b740Confidential
202007 - A scanner could not be initialized
137 202007 - A scanner could not be initialized
137.1 Failure Event Report
137.2 Error DescriptionThe addressed scanner could not be initialized. The additional text will give the reason (e.g. too many scanners, invalid parameters).
Users at the LMT: To obtain information in the alarm’s additional text field, use the ALARM View window of the LMT:1. Click on the “Alarm View” button or use the shortcut key Ctrl + A .2. Concentrate on the ’Additional Text’ column.
Users at the RC: To obtain information in the alarm’s additional text field, use the Alarm Monitoring application of the Radio Commander:1. Select and open the icon “Alarm Monitoring” in the Application Launcher window
(double left-click).2. Concentrate on the ’Additional Text’ column
If the problem is a misconfiguration, the scanner will be created but will be disabled. Lock the scanner, fix the configuration, then unlock to clear the error.
137.3 Troubleshooting (LMT)Take the following measures to clear the alarm cause:1. Lock the reporting scanner type.
Use the TREE View window of the LMT in order to set the administrative state of the relevant scanner to locked.
2. Fix the configuration.3. Set the administrative state of the addressed scanner to unlocked in order to clear
the error.Use the TREE View window of the LMT.
Managed Object Class / Hardware Type:
Scanner, ScannerHsxpa, Scanner Tnl
Event Type: processingErrorAlarm
Probable Cause: ConfigurationOrCustomizationError
Severity: minor
DN70580522 Issue 01A
193
Troubleshooting Node B 202008 - The temporary measurement results couldnot be stored
Id:0900d8058022b746Confidential
138 202008 - The temporary measurement results could not be stored
138.1 Failure Event Report
138.2 Error DescriptionThe internal temporary measurement results could not be stored. The reporting scanner will no longer perform any measurements and will be set to disabled. The Node B may need to be reset before measurements can be restarted correctly.
138.3 Troubleshooting (LMT)Reset the Node B. Use the TREE View window of the LMT and apply the NodeBFddE “reset” command to the NodeBFddE managed object.
Managed Object Class / Hardware Type:
Scanner, ScannerHsxpa, Scanner Tnl
Event Type: processingErrorAlarm
Probable Cause: FileError
Severity: minor
194 DN70580522Issue 01A
Troubleshooting Node B
Id:0900d8058022b74cConfidential
202009 - Unable to request measurement results
139 202009 - Unable to request measurement results
139.1 Failure Event Report
139.2 Error DescriptionOne or more of the measurement results for the addressed scanner could not be requested. These measurements will be marked as suspect for the current granularity period. The scanner will try to request these measurements again at the end of the next granularity period. If the next request for reports is successful, the fault will automatically be cleared.
139.3 Troubleshooting (LMT)Contact the technical assistance center (TAC) to get support in isolating the fault. For suitable preparation save the error symptoms as described in “Collect Info for Assis-tance”. Log files need to be analyzed and specific measures must be taken which are out of the operator’s scope.
Managed Object Class / Hardware Type:
Scanner, ScannerHsxpa, Scanner Tnl
Event Type: processingErrorAlarm
Probable Cause: SystemCallUnsuccessful
Severity: minor
DN70580522 Issue 01A
195
Troubleshooting Node B 202010 - The ScanCo could not be initialized
Id:0900d8058022b752Confidential
140 202010 - The ScanCo could not be initialized
140.1 Failure Event Report
140.2 Error DescriptionA ScanCo could not be created. The additional text will give the reason for the failure. As a consequence, performance measurements will not be started on the relevant Node B.
140.3 Troubleshooting (LMT)Contact the technical assistance center (TAC) to get support in isolating the fault. For suitable preparation save the error symptoms as described in “Collect Info for Assis-tance”. Log files need to be analyzed and specific measures must be taken which are out of the operator’s scope.
Managed Object Class / Hardware Type:
ScanCo
Event Type: processingErrorAlarm
Probable Cause: ConfigurationOrCustomizationError
Severity: minor
196 DN70580522Issue 01A
Troubleshooting Node B
Id:0900d8058022b758Confidential
202011 - The final results files could not be generated
141 202011 - The final results files could not be generated
141.1 Failure Event Report
141.2 Error DescriptionThe temporary measurement results of the reporting ScanCo could not be converted into a final results files.
This failure will have the following impacts: • The upload in progress will be aborted. • Some measurement files will be lost. • A Node B reset may be required before further upload attempts will be successful.
141.3 Troubleshooting (LMT)Reset the associated Node B. Use the TREE View window of the LMT and apply the NodeBFddE “reset” command to the relevant NodeBFddE managed object.
Managed Object Class / Hardware Type:
ScanCo
Event Type: processingErrorAlarm
Probable Cause: FileError
Severity: minor
DN70580522 Issue 01A
197
Troubleshooting Node B 202014 - The first sccpchUsageRatio Quality of Servicealarm has occurred
Id:0900d8058022b760Confidential
142 202014 - The first sccpchUsageRatio Quality of Service alarm has occurred
142.1 Failure Event Report
142.2 Error DescriptionThe first sccpchUsageRatio threshold-crossing alarm was raised. This is a QoS alarm which was not generated by any HW or SW error.
The operator can set four thresholds of any percentage for sccpchUsageRatio: notify high 1/2 and notify low 1/2 which raise and clear the related alarms (202014 - The first sccpchUsageRatio Quality of Service alarm has occurred / 202015 - The second sccp-chUsageRatio Quality of Service alarm has occurred), respectively, when crossed. Fur-thermore, the operator can determine an alarm severity for each of the relevant QoS alarms. All values are related to call-processing resources of the Node B.
If many subscribers within one UTRAN cell use their UEs at the same time, a shortage of HW resources in this cell may occur as a consequence and this alarm will be output.
142.3 Troubleshooting (LMT)Re-consider the current network design. If possible, modify the configuration of the adjacent cells so that the same area of this cell is covered by several Node Bs. This may help to solve the lack of resources without a system crash.
Furthermore, contact the technical assistance center (TAC) to get support in isolating the fault. For suitable preparation save the error symptoms as described in “Collect Info for Assistance”. Log files need to be analyzed and specific measures must be taken which are out of the operator’s scope.
As soon as this QoS alarm is ceased, relevant threshold information will be displayed.
Managed Object Class / Hardware Type:
LocalCellE
Event Type: qualityOfServiceAlarm
Probable Cause: ThresholdCrossed
Severity: indeterminate
198 DN70580522Issue 01A
Troubleshooting Node B
Id:0900d8058022b766Confidential
202015 - The second sccpchUsageRatio Quality of Service alarm has occurred
143 202015 - The second sccpchUsageRatio Quality of Service alarm has occurred
143.1 Failure Event Report
143.2 Error DescriptionThe second sccpchUsageRatio threshold-crossing alarm was raised. This is a QoS alarm which was not generated by any HW or SW error.
The operator can set four thresholds of any percentage for sccpchUsageRatio: notify high 1/2 and notify low 1/2 which raise and clear the related alarms (202014 - The first sccpchUsageRatio Quality of Service alarm has occurred / 202015 - The second sccp-chUsageRatio Quality of Service alarm has occurred), respectively, when crossed. Fur-thermore, the operator can determine an alarm severity for each of the relevant QoS alarms. All values are related to call-processing resources of the Node B.
If many subscribers within one UTRAN cell use their UEs at the same time, a shortage of HW resources in this cell may occur as a consequence and this alarm will be output.
143.3 Troubleshooting (LMT)Re-consider the current network design. If possible, modify the configuration of the adjacent cells so that the same area of this cell is covered by several Node Bs. This may help to solve the lack of resources without a system crash.
Furthermore, contact the technical assistance center (TAC) to get support in isolating the fault. For suitable preparation save the error symptoms as described in “Collect Info for Assistance”. Log files need to be analyzed and specific measures must be taken which are out of the operator’s scope.
As soon as this QoS alarm is ceased, relevant threshold information will be displayed.
Managed Object Class / Hardware Type:
LocalCellE
Event Type: qualityOfServiceAlarm
Probable Cause: ThresholdCrossed
Severity: indeterminate
DN70580522 Issue 01A
199
Troubleshooting Node B 202016 - The first prachUsageRatio Quality of Servicealarm has occurred
Id:0900d8058022b76cConfidential
144 202016 - The first prachUsageRatio Quality of Service alarm has occurred
144.1 Failure Event Report
144.2 Error DescriptionThe first prachUsageRatio threshold-crossing alarm was raised. This is a QoS alarm which was not generated by any HW or SW error.
The operator can set four thresholds of any percentage for prachUsageRatio: notify high 1/2 and notify low 1/2 which raise and clear the related alarms (202016 - The first prachUsageRatio Quality of Service alarm has occurred / 202017 - The second pra-chUsageRatio Quality of Service alarm has occurred), respectively, when crossed. Fur-thermore, the operator can determine an alarm severity for each of the relevant QoS alarms. All values are related to call-processing resources of the Node B.
If many subscribers within one UTRAN cell use their UEs at the same time, a shortage of HW resources in this cell may occur as a consequence and this alarm will be output.
144.3 Troubleshooting (LMT)Re-consider the current network design. If possible, modify the configuration of the adjacent cells so that the same area of this cell is covered by several Node Bs. This may help to solve the lack of resources without a system crash.
Furthermore, contact the technical assistance center (TAC) to get support in isolating the fault. For suitable preparation save the error symptoms as described in “Collect Info for Assistance”. Log files need to be analyzed and specific measures must be taken which are out of the operator’s scope.
As soon as this QoS alarm is ceased, relevant threshold information will be displayed.
Managed Object Class / Hardware Type:
LocalCellE
Event Type: qualityOfServiceAlarm
Probable Cause: ThresholdCrossed
Severity: indeterminate
200 DN70580522Issue 01A
Troubleshooting Node B
Id:0900d8058022b772Confidential
202017 - The second prachUsageRatio Quality of Ser-vice alarm has occurred
145 202017 - The second prachUsageRatio Quality of Service alarm has occurred
145.1 Failure Event Report
145.2 Error DescriptionThe second prachUsageRatio threshold-crossing alarm was raised. This is a QoS alarm which was not generated by any HW or SW error.
The operator can set four thresholds of any percentage for prachUsageRatio: notify high 1/2 and notify low 1/2 which raise and clear the related alarms (202016 - The first prachUsageRatio Quality of Service alarm has occurred / 202017 - The second pra-chUsageRatio Quality of Service alarm has occurred), respectively, when crossed. Fur-thermore, the operator can determine an alarm severity for each of the relevant QoS alarms. All values are related to call-processing resources of the Node B.
If many subscribers within one UTRAN cell use their UEs at the same time, a shortage of HW resources in this cell may occur as a consequence and this alarm will be output.
145.3 Troubleshooting (LMT)Re-consider the current network design. If possible, modify the configuration of the adjacent cells so that the same area of this cell is covered by several Node Bs. This may help to solve the lack of resources without a system crash.
Furthermore, contact the technical assistance center (TAC) to get support in isolating the fault. For suitable preparation save the error symptoms as described in “Collect Info for Assistance”. Log files need to be analyzed and specific measures must be taken which are out of the operator’s scope.
As soon as this QoS alarm is ceased, relevant threshold information will be displayed.
Managed Object Class / Hardware Type:
LocalCellE
Event Type: qualityOfServiceAlarm
Probable Cause: ThresholdCrossed
Severity: indeterminate
DN70580522 Issue 01A
201
Troubleshooting Node B 202018 - The first cpUsageRatio Quality of Servicealarm has occurred
Id:0900d8058022b77aConfidential
146 202018 - The first cpUsageRatio Quality of Service alarm has occurred
146.1 Failure Event Report
146.2 Error DescriptionThe first cpUsageRatio threshold-crossing alarm was raised. This is a QoS alarm which was not generated by any HW or SW error.
The operator can set four thresholds of any percentage for cpUsageRatio: notify high 1/2 and notify low 1/2 which raise and clear the related alarms (202018 - The first cpUsageRatio Quality of Service alarm has occurred / 202019 - The second cpUsageR-atio Quality of Service alarm has occurred), respectively, when crossed. Furthermore, the operator can determine an alarm severity for each of the relevant QoS alarms. All values are related to call-processing resources of the Node B.
If many subscribers within one UTRAN cell use their UEs at the same time, a shortage of HW resources in this cell may occur as a consequence and this alarm will be output.
146.3 Troubleshooting (LMT)Re-consider the current network design. If possible, modify the configuration of the adjacent cells so that the same area of this cell is covered by several Node Bs. This may help to solve the lack of resources without a system crash.
Furthermore, contact the technical assistance center (TAC) to get support in isolating the fault. For suitable preparation save the error symptoms as described in “Collect Info for Assistance”. Log files need to be analyzed and specific measures must be taken which are out of the operator’s scope.
As soon as this QoS alarm is ceased, relevant threshold information will be displayed.
Managed Object Class / Hardware Type:
NodeBFddE
Event Type: qualityOfServiceAlarm
Probable Cause: ThresholdCrossed
Severity: indeterminate
202 DN70580522Issue 01A
Troubleshooting Node B
Id:0900d8058022b780Confidential
202019 - The second cpUsageRatio Quality of Service alarm has occurred
147 202019 - The second cpUsageRatio Quality of Service alarm has occurred
147.1 Failure Event Report
147.2 Error DescriptionThe second cpUsageRatio threshold-crossing alarm was raised. This is a QoS alarm which was not generated by any HW or SW error.
The operator can set four thresholds of any percentage for cpUsageRatio: notify high 1/2 and notify low 1/2 which raise and clear the related alarms (202018 - The first cpUsageRatio Quality of Service alarm has occurred / 202019 - The second cpUsageR-atio Quality of Service alarm has occurred), respectively, when crossed. Furthermore, the operator can determine an alarm severity for each of the relevant QoS alarms. All values are related to call-processing resources of the Node B.
If many subscribers within one UTRAN cell use their UEs at the same time, a shortage of HW resources in this cell may occur as a consequence and this alarm will be output.
147.3 Troubleshooting (LMT)Re-consider the current network design. If possible, modify the configuration of the adjacent cells so that the same area of this cell is covered by several Node Bs. This may help to solve the lack of resources without a system crash.
Furthermore, contact the technical assistance center (TAC) to get support in isolating the fault. For suitable preparation save the error symptoms as described in “Collect Info for Assistance”. Log files need to be analyzed and specific measures must be taken which are out of the operator’s scope.
As soon as this QoS alarm is ceased, relevant threshold information will be displayed.
Managed Object Class / Hardware Type:
NodeBFddE
Event Type: qualityOfServiceAlarm
Probable Cause: ThresholdCrossed
Severity: indeterminate
DN70580522 Issue 01A
203
Troubleshooting Node B 202020 - The first prachCrciFailures Quality of Servicealarm has occurred
Id:0900d8058022b786Confidential
148 202020 - The first prachCrciFailures Quality of Service alarm has occurred
148.1 Failure Event Report
148.2 Error DescriptionThe first prachCrciFailures threshold-crossing alarm was raised. This is a QoS alarm which was not generated by any HW or SW error.
The operator can set four thresholds of any percentage for cpUsageRatio: notify high 1/2 and notify low 1/2 which raise and clear the related alarms (202020 - The first prachCrciFailures Quality of Service alarm has occurred / 202021 - The second prach-CrciFailures Quality of Service alarm has occurred), respectively, when crossed. Fur-thermore, the operator can determine an alarm severity for each of the relevant QoS alarms. All values are related to call-processing resources of the Node B.
If many subscribers within one UTRAN cell use their UEs at the same time, a shortage of HW resources in this cell may occur as a consequence and this alarm will be output.
148.3 Troubleshooting (LMT)Re-consider the current network design. If possible, modify the configuration of the adjacent cells so that the same area of this cell is covered by several Node Bs. This may help to solve the lack of resources without a system crash.
Furthermore, contact the technical assistance center (TAC) to get support in isolating the fault. For suitable preparation save the error symptoms as described in “Collect Info for Assistance”. Log files need to be analyzed and specific measures must be taken which are out of the operator’s scope.
As soon as this QoS alarm is ceased, relevant threshold information will be displayed.
Managed Object Class / Hardware Type:
LocalCellE
Event Type: qualityOfServiceAlarm
Probable Cause: ThresholdCrossed
Severity: indeterminate
204 DN70580522Issue 01A
Troubleshooting Node B
Id:0900d8058022b78cConfidential
202021 - The second prachCrciFailures Quality of Ser-vice alarm has occurred
149 202021 - The second prachCrciFailures Quality of Service alarm has occurred
149.1 Failure Event Report
149.2 Error DescriptionThe second prachCrciFailures threshold-crossing alarm was raised. This is a QoS alarm which was not generated by any HW or SW error.
The operator can set four thresholds of any percentage for cpUsageRatio: notify high 1/2 and notify low 1/2 which raise and clear the related alarms (202020 - The first prachCrciFailures Quality of Service alarm has occurred / 202021 - The second prach-CrciFailures Quality of Service alarm has occurred), respectively, when crossed. Fur-thermore, the operator can determine an alarm severity for each of the relevant QoS alarms. All values are related to call-processing resources of the Node B.
If many subscribers within one UTRAN cell use their UEs at the same time, a shortage of HW resources in this cell may occur as a consequence and this alarm will be output.
149.3 Troubleshooting (LMT)Re-consider the current network design. If possible, modify the configuration of the adjacent cells so that the same area of this cell is covered by several Node Bs. This may help to solve the lack of resources without a system crash.
Furthermore, contact the technical assistance center (TAC) to get support in isolating the fault. For suitable preparation save the error symptoms as described in “Collect Info for Assistance”. Log files need to be analyzed and specific measures must be taken which are out of the operator’s scope.
As soon as this QoS alarm is ceased, relevant threshold information will be displayed.
Managed Object Class / Hardware Type:
LocalCellE
Event Type: qualityOfServiceAlarm
Probable Cause: ThresholdCrossed
Severity: indeterminate
DN70580522 Issue 01A
205
Troubleshooting Node B 202022 - The first bbUsageRatioLicense Quality of Ser-vice alarm has occurred
Id:0900d8058022b794Confidential
150 202022 - The first bbUsageRatioLicense Quality of Service alarm has occurred
150.1 Failure Event Report
150.2 Error DescriptionThe first bbUsageRatioLicense threshold-crossing alarm was raised . This is a QoS alarm which was not generated by any HW or SW error.
The operator can set four thresholds of any percentage for bbUsageRatioLicense: notify high 1/2 and notify low 1/2 which raise and clear the related alarms (202022 - The first bbUsageRatioLicense Quality of Service alarm has occurred / 202023 - The second bbUsageRatioLicense Quality of Service alarm has occurred), respectively, when crossed. Furthermore, the operator can determine an alarm severity for each of the relevant QoS alarms. All values are related to call-processing resources of the Node B.
If many subscribers within one UTRAN cell use their UEs at the same time, a shortage of the purchased channel element (CE) license resources may occur as a consequence and this alarm will be output.
150.3 Troubleshooting (LMT)Take the following measures to clear this alarm:1. The number of channel element (CE) licenses available is not sufficient.
Purchase additional CE licenses.2. If purchasing additional CE licenses does not help to solve the error reported,
contact the technical assistance center (TAC) to get support in isolating the fault. For suitable preparation save the error symptoms as described in “Collect Info for Assis-tance”. Log files need to be analyzed and specific measures must be taken which are out of the operator’s scope.
As soon as this QoS alarm is ceased, relevant threshold information will be displayed.
Managed Object Class / Hardware Type:
NodeBFddE
Event Type: qualityOfServiceAlarm
Probable Cause: ThresholdCrossed
Severity: indeterminate
206 DN70580522Issue 01A
Troubleshooting Node B
Id:0900d8058022b79cConfidential
202023 - The second bbUsageRatioLicense Quality of Service alarm has occurred
151 202023 - The second bbUsageRatioLicense Quality of Service alarm has occurred
151.1 Failure Event Report
151.2 Error DescriptionThe second bbUsageRatioLicense threshold-crossing alarm was raised . This is a QoS alarm which was not generated by any HW or SW error.
The operator can set four thresholds of any percentage for bbUsageRatioLicense: notify high 1/2 and notify low 1/2 which raise and clear the related alarms (202022 - The first bbUsageRatioLicense Quality of Service alarm has occurred / 202023 - The second bbUsageRatioLicense Quality of Service alarm has occurred), respectively, when crossed. Furthermore, the operator can determine an alarm severity for each of the relevant QoS alarms. All values are related to call-processing resources of the Node B.
If many subscribers within one UTRAN cell use their UEs at the same time, a shortage of the purchased channel element (CE) license resources may occur as a consequence and this alarm will be output.
151.3 Troubleshooting (LMT)Take the following measures to clear this alarm:1. The number of channel element (CE) licenses, which are available, is not sufficient.
Purchase additional CE licenses.2. If purchasing additional CE licenses does not help to solve the error reported,
contact the technical assistance center (TAC) to get support in isolating the fault. For suitable preparation save the error symptoms as described in “Collect Info for Assis-tance”. Log files need to be analyzed and specific measures must be taken which are out of the operator’s scope.
As soon as this QoS alarm is ceased, relevant threshold information will be displayed.
Managed Object Class / Hardware Type:
NodeBFddE
Event Type: qualityOfServiceAlarm
Probable Cause: ThresholdCrossed
Severity: indeterminate
DN70580522 Issue 01A
207
Troubleshooting Node B 202024 - The first bbUsageRatioHw Quality of Servicealarm has occurred
Id:0900d8058022b7a4Confidential
152 202024 - The first bbUsageRatioHw Quality of Service alarm has occurred
152.1 Failure Event Report
152.2 Error DescriptionThe first bbUsageRatioHw threshold-crossing alarm was raised. This is a QoS alarm which was not generated by any HW or SW error.
The operator can set four thresholds of any percentage for bbUsageRatioHw: notify high 1/2 and notify low 1/2 which raise and clear the related alarms (202024 - The first bbUsageRatioHw Quality of Service alarm has occurred / 202025 - The second bbUs-ageRatioHw Quality of Service alarm has occurred), respectively, when crossed. Fur-thermore, the operator can determine an alarm severity for each of the relevant QoS alarms. All values are related to call-processing resources of the Node B.
If many subscribers use their UEs at the same time, a shortage of hardware resources in this cell may occur as a consequence and this alarm will be output.
152.3 Troubleshooting (LMT)Re-consider the current network design. If possible, modify the configuration of the adjacent cells so that the same area of this cell is covered by several Node Bs. This may help to solve the lack of resources without any system crash.
Furthermore, contact the technical assistance center (TAC) to get support in isolating the fault. For suitable preparation save the error symptoms as described in “Collect Info for Assistance”. Log files need to be analyzed and specific measures must be taken which are out of the operator’s scope.
As soon as this QoS alarm is ceased, relevant threshold information will be displayed.
Managed Object Class / Hardware Type:
NodeBFddE
Event Type: qualityOfServiceAlarm
Probable Cause: ThresholdCrossed
Severity: indeterminate
208 DN70580522Issue 01A
Troubleshooting Node B
Id:0900d8058022b7acConfidential
202025 - The second bbUsageRatioHw Quality of Ser-vice alarm has occurred
153 202025 - The second bbUsageRatioHw Quality of Service alarm has occurred
153.1 Failure Event Report
153.2 Error DescriptionThe second bbUsageRatioHw threshold-crossing alarm was raised. This is a QoS alarm which was not generated by any HW or SW error.
The operator can set four thresholds of any percentage for bbUsageRatioHw: notify high 1/2 and notify low 1/2 which raise and clear the related alarms (202024 - The first bbUs-ageRatioHw Quality of Service alarm has occurred / 202025 - The second bbUsageR-atioHw Quality of Service alarm has occurred), respectively, when crossed. Furthermore, the operator can determine an alarm severity for each of the relevant QoS alarms. All values are related to call-processing resources of the Node B.
If many subscribers within one cell use their UEs at the same time, a shortage of hardware resources in this cell may occur as a consequence and this alarm will be output.
153.3 Troubleshooting (LMT)Re-consider the current network design. If possible, modify the configuration of the adjacent cells so that the same area of this cell is covered by several Node Bs. This may help to solve the lack of resources without any system crash..
Furthermore, contact the technical assistance center (TAC) to get support in isolating the fault. For suitable preparation save the error symptoms as described in “Collect Info for Assistance”. Log files need to be analyzed and specific measures must be taken which are out of the operator’s scope.
As soon as this QoS alarm is ceased, relevant threshold information will be displayed.
Managed Object Class / Hardware Type:
NodeBFddE
Event Type: qualityOfServiceAlarm
Probable Cause: ThresholdCrossed
Severity: indeterminate
DN70580522 Issue 01A
209
Troubleshooting Node B 202026 - The first e1Crc Quality of Service alarm hasoccurred
Id:0900d8058022b7b2Confidential
154 202026 - The first e1Crc Quality of Service alarm has occurred
154.1 Failure Event Report
154.2 Error DescriptionThe first e1Crc threshold crossing alarm has been raised. This is a QoS alarm which has been raised due to bad signal quality on the reporting E1 line, resulting in high bit error ratios (BERs).
Operators can set four thresholds of any values within the allowed range for e1Crc: notify high 1/2 and notify low 1/2 which raise and clear the related alarms (“202026 – The first e1Crc Quality of Service alarm has occurred” / “202027 – The second e1Crc Quality of Service alarm has occurred”), respectively, when crossed.
If the BER increases, the “202027 – The second e1Crc Quality of Service alarm has occurred” alarm will be output in addition to the “202026 – The first e1Crc Quality of Service alarm has occurred” alarm.
Whenever the “202026 – The first e1Crc Quality of Service alarm has occurred” alarm is output, the consequence for the related E1 line depends on whether or not the “202027 – The second e1Crc Quality of Service alarm has occurred” is output, too. The consequences for the E1 line are provided subsequently.
154.3 Troubleshooting (LMT)Contact the technical assistance center (TAC) to get support in isolating the fault. For suitable preparation save the error symptoms as described in Collect Info for Assis-tance. Log files need to be analyzed and specific measures must be taken which are out of the operator’s scope.
As soon as this QoS alarm is ceased • Relevant threshold information will be displayed
Managed Object Class / Hardware Type:
E1TTP
Event Type: qualityOfServiceAlarm
Probable Cause: ThresholdCrossed
Severity: Indeterminate
Condition of QoS Alarm (ID)… Consequence for the E1 Line Remark
202026 (1st QoS Alarm) 202027 (2nd QoS Alarm) OST AVS RAI
Cleared Cleared enabled empty set cleared
Raised Cleared enabled degraded cleared
Raised Raised disabled failed raised Refer to the “Error Description” of the 2nd QoS Alarm (202027).
210 DN70580522Issue 01A
Troubleshooting Node B
Id:0900d8058022b7b2Confidential
202026 - The first e1Crc Quality of Service alarm has occurred
• The AVS of the E1 line will be set to empty set.
DN70580522 Issue 01A
211
Troubleshooting Node B 202027 - The second e1Crc Quality of Service alarmhas occurred
Id:0900d8058022ac61Confidential
155 202027 - The second e1Crc Quality of Service alarm has occurred
155.1 Failure Event Report
155.2 Error DescriptionThe second e1Crc threshold-crossing alarm has been raised. This is a QoS alarm which has been raised due to bad signal quality on the reporting E1 line, resulting in high bit error ratios (BERs).
Operators can set four thresholds of any values within the allowed range for e1Crc: notify high 1/2 and notify low 1/2 which raise and clear the related alarms (“202026 – The first e1Crc Quality of Service alarm has occurred” / “202027 – The second e1Crc Quality of Service alarm has occurred”), respectively, when crossed.
☞ Whenever the “202027 – The second e1Crc Quality of Service alarm has occurred” alarm is active, the “202026 – The first e1Crc Quality of Service alarm has occurred” is active, too.
As a consequence of this alarm, the reporting managed object (E1TTP) will be set to OST = disabled and AVS = failed, except for E1 lines required by VCs (VcTTP managed object) used for • FTP and OAM • ALCAP • NBAPAdditionally, a remote alarm indication (RAI) signal will be sent to the far end in upstream direction. Depending on the network topology and if the far end (FE) equipment is an NB/RSAxxx, the RAI may be indicated by the following alarm: 202060 – Remote Alarm Indication on Physical Link.
Corresponding alarms may be reported for the RNC, other Node B types, or link equipment (LE).
The E1 line related to the reporting E1TTP object will not be used for traffic anymore until the “202027 – The second e1Crc Quality of Service alarm has occurred” alarm and the subsequent RAI signal are cleared. The exception mentioned before still applies, however.
155.3 Troubleshooting (LMT)Contact the technical assistance center (TAC) to get support in isolating the fault. For suitable preparation save the error symptoms as described in “Collect Info for Assis-
Managed Object Class / Hardware Type:
E1TTP
Event Type: qualityOfServiceAlarm
Probable Cause: ThresholdCrossed
Severity: Indeterminate
212 DN70580522Issue 01A
Troubleshooting Node B
Id:0900d8058022ac61Confidential
202027 - The second e1Crc Quality of Service alarm has occurred
tance”. Log files need to be analyzed and specific measures must be taken which are out of the operator’s scope.
As soon as this QoS alarm is ceased, relevant threshold information will be displayed. The consequence for the E1 line depends on whether or not the first e1Crc threshold-crossing QoS alarm is also ceased. For details, consult the “202026 – The first e1Crc Quality of Service alarm has occurred” alarm’s “Error Description”.
DN70580522 Issue 01A
213
Troubleshooting Node B 202028 - The first vcUsageRatio Quality of Servicealarm has occurredAlarm added
Id:0900d8058022b7c0Confidential
156 202028 - The first vcUsageRatio Quality of Service alarm has occurredAlarm added
156.1 Failure Event Report
156.2 Error DescriptionThe first vcUsageRatio threshold-crossing alarm was raised. This is a QoS alarm which was not generated by any HW or SW error.
The operator can set four thresholds of any values for prachCrciFailures: notify high 1/2 and notify low 1/2 which raise and clear the related alarms (202028 - The first vcUsag-eRatio Quality of Service alarm has occurred / 202029 - The second vcUsageRatio Quality of Service alarm has occurred),respectively, when crossed. Furthermore, the operator can determine an alarm severity for each of the relevant QoS alarms. All values are related to call-processing resources of the Node B.
156.3 Troubleshooting (LMT)Re-consider the current network design. If possible, modify the configuration of the adjacent cells so that the same area of this cell is covered by several Node Bs. This may help to solve the lack of resources without a system crash.
Furthermore, contact the technical assistance center (TAC) to get support in isolating the fault. For suitable preparation save the error symptoms as described in “Collect Info for Assistance”. Log files need to be analyzed and specific measures must be taken which are out of the operator’s scope.
As soon as this QoS alarm is ceased, relevant threshold information will be displayed.
Managed Object Class / Hardware Type:
VcCTP
Event Type: qualityOfServiceAlarm
Probable Cause: ThresholdCrossed
Severity: indeterminate
214 DN70580522Issue 01A
Troubleshooting Node B
Id:0900d8058022b7c8Confidential
202029 - The second vcUsageRatio Quality of Service alarm has occurred
157 202029 - The second vcUsageRatio Quality of Service alarm has occurred
157.1 Failure Event Report
157.2 Error DescriptionThe second vcUsageRatio threshold-crossing alarm was raised. This is a QoS alarm which was not generated by any HW or SW error.
The operator can set four thresholds of any values for prachCrciFailures: notify high 1/2 and notify low 1/2 which raise and clear the related alarms (202028 - The first vcUsag-eRatio Quality of Service alarm has occurred / 202029 - The second vcUsageRatio Quality of Service alarm has occurred),respectively, when crossed. Furthermore, the operator can determine an alarm severity for each of the relevant QoS alarms. All values are related to call-processing resources of the Node B.
157.3 Troubleshooting (LMT)Re-consider the current network design. If possible, modify the configuration of the adjacent cells so that the same area of this cell is covered by several Node Bs. This may help to solve the lack of resources without a system crash.
Furthermore, contact the technical assistance center (TAC) to get support in isolating the fault. For suitable preparation save the error symptoms as described in “Collect Info for Assistance”. Log files need to be analyzed and specific measures must be taken which are out of the operator’s scope.
As soon as this QoS alarm is ceased, relevant threshold information will be displayed.
Managed Object Class / Hardware Type:
VcCTP
Event Type: qualityOfServiceAlarm
Probable Cause: ThresholdCrossed
Severity: indeterminate
DN70580522 Issue 01A
215
Troubleshooting Node B 202056 - Loss Of Signal on Physical Link
Id:0900d80580228b89Confidential
158 202056 - Loss Of Signal on Physical Link
158.1 Failure Event Report
158.2 Error DescriptionLoss of signal (LOS) indication has been received on a physical link E1, J1, T1 or STM-1/OC-3 (according to reported MOC in the failure event report). This indicates that the signal from the next device upstream is not present. This may be due to misconfig-uration of the hardware at either end, faulty hardware at either end or due to a break in the transmission medium between the two ends.
The loss of signal may be the root cause for alarms indicated by different NEs in the supervision of the RC. If this NE is an NB/RSxxx, the following subsequent alarms may be output: • Downstream direction:
– 202059 - Alarm Indication Signal on Physical Link– 202062 - Line Alarm Indication Signal Indication on STM1 Physical Link
• Upstream direction:– 202060 - Remote Alarm Indication on Physical Link– 202063 - Line Remote Defect Indication on STM1 Physical Link
Additionally, the LOS causes the reporting Node B’s system clock to switch in holdover mode, indicated by the 202506 - Node B system clock in holdover mode alarm.
158.3 Troubleshooting (LMT)Usually the Node B is connected to the RNC or each other (Iub interface) via Link Equip-ment (LE, such as SDH/PDH multiplexers, ATM switches, or repeaters) and in some rare cases by direct lines. If LE is involved the operation and maintenance system of this network has to be used for getting information about the state and status of the relevant network element (NE).
Depending on the applied configuration of the Node Bs such as star, hub, cascade or loop not only the reported Node B of this error message is affected but also subordi-nated Node Bs.
• Star configurationOnly the reported Node B
• Hub configurationIf the hub Node B is the reporting one for a connection to the RNC:– For E1/J1/T1: the supplied Node B of the relevant E1/J1/T1 link will report AIS– For STM-1/OC-3: all supplied Node Bs will report AIS
Managed Object Class / Hardware Type:
E1TTP, J1TTP, Stm1TP
Event Type: communicationsAlarm
Probable Cause: LossOfSignal
Severity: major
216 DN70580522Issue 01A
Troubleshooting Node B
Id:0900d80580228b89Confidential
202056 - Loss Of Signal on Physical Link
• Cascade configurationAll Node Bs in the chain downstream the LOS reporting Node B will initiate a VP AIS error message for the relevant E1/J1/T1 link respectively all if the first Node B is reporting and connected to the RNC via STM-1/OC-3.
• Loop configurationThe redundant path in the loop configuration will take over the traffic
To isolate the fault check for other error messages in the following order:1. Is there also an equipment alarm of the Core Controller (CC) in the reporting Node B
present?Using the ALARM View window of the LMT:– Click on the “Alarm View” button or use the shortcut key Ctrl + A
– Use the filter and sort function to concentrate on CC alarmsIf an equipment alarm of the CC is present try to fix this fault first which probably also eliminates the LOS alarm.
2. Is the LE, which is connected to the relevant port, reporting an equipment alarm?– If an equipment alarm at the LE is present try to fix this fault first which probably
also eliminates the LOS alarm.3. Check the cable connection
– Take special care if an optical STM-1/OC-3 line is used (see warning above)– Proper connection at the LE (good contact, clean optical connector)– Proper connection at the Node B (good contact, clean optical connector)– Undamaged cable between Node B and LE respectively other Node B or RNC
4. Check the OVPT or IUBCONElectrical Iub lines (E1/J1/T1) are connected to the Node B using an OVPT (over-voltage protection and tracer module) equipped with surge arresters or an IUBCON (Iub connector). Both are available for coax and symmetrical cables.– Check surge arresters at OVPT and replace a defective one if necessary– Replace OVPT or IUBCON if any other reason could not be found. Replacement
must be done according to the “Replacing Node B Units” instructions.
Configuration mismatch?Is the configuration of the relevant ports at either end in accordance with each other? • For Node B use the LMT to upload the nbDatabase and analyze the settings for the
relevant port • For LE the appropriate local maintenance system has to be used
If the misconfiguration can be identified as probable cause for the error report the align-ment of the settings should clear the fault.
!WARNING: Radiation from laser devices (EN 60825/IEC 60825).
Damage of health may occur.
To avoid damage to health, you must observe the regulations regarding protection against radiation from laser devices (EN 60825/IEC 60825). • You must always use dedicated laser-protective goggles. • Never look into open fiber-optic cable ends, as this may damage your eyes.
DN70580522 Issue 01A
217
Troubleshooting Node B 202057 - Loss Of Frame on Physical Link
Id:0900d80580228b8bConfidential
159 202057 - Loss Of Frame on Physical Link
159.1 Failure Event Report
159.2 Error DescriptionLoss of frame (LOF) indication has been received on a physical link E1, J1, T1 or STM-1/OC-3 (according to reported MOC in the failure event report).
This alarm indicates one of the following: • Basic frame synchronization has been lost on the transport interface between the
Node B and the next device upstream.This may be due to– Misconfiguration of the hardware at either end– Faulty hardware at either end– Problems on the transmission medium between the two endsThe loss of basic frame alignment always causes the output of this alarm, indepen-dent of the Node B’s mode of CRC operation (disabled, automatic, forced).
• Although both frame alignment is active and the reporting line is running, a great number of CRC-4 errors occurred. This failure causes the output of the ’Loss of Frame on Physical Link’ alarm only if the Node B operates in CRC forced mode.The loss of frame is indicated when the number of detected CRC-4 errors exceeds a threshold 914 negative comparisons out of 1,000 CRC-4 checks per second. In this case, the Node B goes out of synchronization.
The loss of frame may be the root cause for alarms indicated by different NEs in the supervision of the RC. If this NE is an NB/RSxxx, the following subsequent alarms may be output: • Downstream direction:
– 202059 - Alarm Indication Signal on Physical Link– 202062 - Line Alarm Indication Signal Indication on STM1 Physical Link
• Upstream direction:– 202060 - Remote Alarm Indication on Physical Link– 202063 - Line Remote Defect Indication on STM1 Physical Link
Additionally, the LOF causes the reporting Node B’s system clock to switch in holdover mode, indicated by the 202506 - Node B system clock in holdover mode alarm.
159.3 Troubleshooting (LMT)Usually the Node B is connected to the RNC or each other (Iub interface) via Link Equip-ment (LE, such as SDH/PDH multiplexers, ATM switches, or repeaters) and in some
Managed Object Class / Hardware Type:
E1TTP, J1TTP, Stm1TP
Event Type: communicationAlarm
Probable Cause: LossOfFrame
Severity: major
218 DN70580522Issue 01A
Troubleshooting Node B
Id:0900d80580228b8bConfidential
202057 - Loss Of Frame on Physical Link
rare cases by direct lines. If LE is involved the operation and maintenance system of this network has to be used for getting information about the state and status of the relevant network element (NE).
Depending on the applied configuration of the Node Bs such as star, hub, cascade or loop not only the reported Node B of this error message is affected but also subordi-nated Node Bs.
• Star configurationonly the reported Node B
• Hub configurationif the hub Node B is the reporting one for a connection to the RNC:– for E1/J1/T1: the supplied Node B of the relevant E1/J1/T1 link will report VP
AIS– for STM-1/OC-3: all supplied Node Bs will report AIS
• Cascade configurationall Node Bs in the chain downstream the LOF reporting Node B will initiate a VP AIS error message for the relevant E1/J1/T1 link respectively all if the first Node B is reporting and connected to the RNC via STM-1/OC-3.
• Loop configurationthe redundant path in the loop configuration will take over the traffic
To isolate the fault check for other error messages in the following order:1. Is there also an equipment alarm of the Core Controller (CC) in the reporting Node B
present?Using the ALARM View window of the LMT:– Click on the “Alarm View” button or use the shortcut key Ctrl + A
– Use the filter and sort function to concentrate on CC alarmsIf an equipment alarm of the CC is present try to fix this fault first which probably also eliminates the LOF alarm.
2. Is the LE, which is connected to the relevant port, reporting an equipment alarm?– If an equipment alarm at the LE is present try to fix this fault first which probably
also eliminates the LOF alarm.3. Check the cable connection
– Take special care if an optical STM-1/OC-3 line is used (see warning above)– Proper connection at the LE (good contact, clean optical connector)– Proper connection at the Node B (good contact, clean optical connector)– Undamaged cable between Node B and LE respectively other Node B or RNC
4. Check the OVPT or IUBCONElectrical Iub lines (E1/J1/T1) are connected to the Node B using an OVPT (over-voltage protection and tracer module) equipped with surge arresters or an IUBCON (Iub connector). Both are available for coax and symmetrical cables.– Check surge arresters at OVPT and replace a defective one if necessary
!WARNING: Radiation from laser devices (EN 60825/IEC 60825).
Damage of health may occur.
To avoid damage to health, you must observe the regulations regarding protection against radiation from laser devices (EN 60825/IEC 60825). • You must always use dedicated laser-protective goggles. • Never look into open fiber-optic cable ends, as this may damage your eyes.
DN70580522 Issue 01A
219
Troubleshooting Node B 202057 - Loss Of Frame on Physical Link
Id:0900d80580228b8bConfidential
– Replace OVPT or IUBCON if any other reason could not be found. Replacement must be done according to the “Replacing Node B Units” instructions.
Configuration mismatch?Is the configuration of the relevant ports at either end in accordance with each other? • For Node B use the LMT to upload the nbDatabase and analyze the settings for the
relevant port • For LE the appropriate local maintenance system has to be used
If the misconfiguration can be identified as probable cause for the error report the align-ment of the settings should clear the fault.
220 DN70580522Issue 01A
Troubleshooting Node B
Id:0900d80580228b8dConfidential
202058 - Loss Of Cell Delineation on Physical Link
160 202058 - Loss Of Cell Delineation on Physical Link
160.1 Failure Event Report
160.2 Error DescriptionLoss of cell delineation (LCD) indication has been received on a physical link E1, J1, T1 or STM-1/OC-3 (according to reported MOC in the failure event report). This indicates that ATM cells are not being delineated correctly and so cannot be extracted from the received signal. This may be due to faulty hardware at either end or problems on the transmission medium between the two ends.
If the reporting Node B is equipped with a CCv3, this alarm may be output due to a database misconfiguration, caused by the following: the “local” Node B is directly con-nected to a “remote” Node B via E1, J1, or T1 line (cascade configuration). The line coding attribute of the E1 or J1/T1 line (e1LineCode or j1LineCode, respectively), however, is set to different values in the “local” and in the “remote” Node B’s DB.
The loss of cell delineation may be the root cause for alarms indicated by different NEs in the supervision of the RC. If this NE is an NB/RSxxx, the following subsequent alarms may be output: • Downstream direction:
– 202060 - Remote Alarm Indication Signal on Physical Link– 202075 - Alarm Indication Signal on an ATM VP
• Upstream direction:– 202076 - Remote Defect Indication on an ATM VP
160.3 Troubleshooting (LMT)Usually the Node B is connected to the RNC or each other (Iub interface) via Link Equip-ment (LE, such as SDH/PDH multiplexers, ATM switches, or repeaters) and in some rare cases by direct lines. If LE is involved the operation and maintenance system of this network has to be used for getting information about the state and status of the relevant network element (NE).
Depending on the applied configuration of the Node Bs such as star, hub, cascade or loop not only the reported Node B of this error message is affected but also subordi-nated Node Bs.
• Star configurationonly the reported Node B
Managed Object Class / Hardware Type:
E1TTP, J1TTP, Stm1TP
Event Type: communicationsAlarm
Probable Cause: LossOfCellDelineation
Severity: major
DN70580522 Issue 01A
221
Troubleshooting Node B 202058 - Loss Of Cell Delineation on Physical Link
Id:0900d80580228b8dConfidential
• Hub configurationif the hub Node B is the reporting one for a connection to the RNC:– for E1/J1/T1: the supplied Node B of the relevant E1/J1/T1 link will report VPAIS– for STM-1/OC-3: all supplied Node Bs will report AIS
• Cascade configurationall Node Bs in the chain downstream the LCD reporting Node B will initiate a VPAIS error message for the relevant E1/J1/T1 link respectively all if the first Node B is reporting and connected to the RNC via STM-1/OC-3.
• Loop configurationthe redundant path in the loop configuration will take over the traffic
To isolate the fault check for other error messages in the following order:
1. Is there also an equipment alarm of the Core Controller (CC) in the reporting Node B present?Using the ALARM View window of the LMT:– Click on the “Alarm View” button or use the shortcut key Ctrl + A
– Use the filter and sort function to concentrate on CC alarmsIf an equipment alarm of the CC is present try to fix this fault first which probably also eliminates the LCD alarm.
2. Is the LE, which is connected to the relevant port, reporting an equipment alarm?– If an equipment alarm at the LE is present try to fix this fault first which probably
also eliminates the LCD alarm.3. Check the cable connection
– Take special care if an optical STM-1/OC-3 line is used (see warning above)– Proper connection at the LE (good contact, clean optical connector)– Proper connection at the Node B (good contact, clean optical connector)– Undamaged cable between Node B and LE respectively other Node B or RNC
4. Check the OVPT or IUBCONElectrical Iub lines (E1/J1/T1) are connected to the Node B using an OVPT (over-voltage protection and tracer module) equipped with surge arresters or an IUBCON (Iub connector). Both are available for coax and symmetrical cables.– Check surge arresters at OVPT and replace a defective one if necessary– Replace OVPT or IUBCON if any other reason could not be found. Replacement
must be done according to the “Replacing Node B Units” instructions.5. Configuration mismatch
Is the configuration of the relevant ports at either end in accordance with each other, for example with regard to the line coding?– for Node B use the LMT to upload the nbDatabase and analyze the settings for
the relevant port
!WARNING: Radiation from laser devices (EN 60825/IEC 60825).
Damage of health may occur.
To avoid damage to health, you must observe the regulations regarding protection against radiation from laser devices (EN 60825/IEC 60825). • You must always use dedicated laser-protective goggles. • Never look into open fiber-optic cable ends, as this may damage your eyes.
222 DN70580522Issue 01A
Troubleshooting Node B
Id:0900d80580228b8dConfidential
202058 - Loss Of Cell Delineation on Physical Link
– for LE the appropriate local maintenance system has to be usedIf the misconfiguration can be identified as probable cause for the error report the alignment of the settings should clear the fault.
6. If none of the proposed actions results in a fault clearance contact the technical assistance center (TAC) to get support in isolating the fault. For suitable preparation save the error symptoms as described in “Collect Info for Assistance”. Log files need to be analyzed and specific measures must be taken which are out of the operator’s scope.
DN70580522 Issue 01A
223
Troubleshooting Node B 202059 - Alarm Indication Signal on Physical Link
Id:0900d80580228b8fConfidential
161 202059 - Alarm Indication Signal on Physical Link
161.1 Failure Event Report
161.2 Error DescriptionAlarm indication signal (AIS) indication has been received on a physical link E1, J1, or T1 (according to reported MOC in the failure event report). This alarm indicates that a problem has been detected upstream from the Node B (backward direction) on the physical link reporting the alarm. Transmission to the Node B from that direction has probably been interrupted on this link. The Node B forwards a VP AIS to the next NE in forward direction (downstream). The AIS are forwarded by all downstream NEs until they reach the NE which terminates the link affected by the failure.
This alarm is triggered by a preceded alarms from another upstream NE in the supervi-sion of the RC. If this NE is an NB/RSxxx, the following alarms may be the trigger: • 202056 - Loss Of Signal on Physical Link • 202057 - Loss Of Frame on Physical Link
Alternatively, an alarm from Link Equipment (LE, such as SDH/PDH multiplexers, ATM switches, or repeaters) in upstream direction may be the root cause, such as: • Loss Of Signal (LOS) • Loss Of Frame (LOF)
Additionally, the AIS causes the reporting Node B’s system clock to switch in holdover mode, indicated by the 202506 - Node B system clock in holdover mode alarm.
161.3 Troubleshooting (LMT)Because this error message is a consequence of a preceded alarm from an upstream NE in the supervision of the RC, the troubleshooting has to start with investigation of the trigger alarm.
As regards Node B PF2 alarms, find the relevant alarm in the list of the ALARM View window of the LMT:1. Click on the “Alarm View” button or use the shortkey Ctrl + A .2. Use the filter and sort function to concentrate on the relevant alarms
As regards any other NE in the supervision of the RC, find the relevant alarm in the list of the Alarm Monitoring Application:1. Select and open the icon “Alarm Monitoring” in the Application Launcher window
(double left-click)
Managed Object Class / Hardware Type:
E1TTP, J1TTP
Event Type: communicationsAlarm
Probable Cause: AlarmIndicationSignal
Severity: major
224 DN70580522Issue 01A
Troubleshooting Node B
Id:0900d80580228b8fConfidential
202059 - Alarm Indication Signal on Physical Link
2. Look for one of the alarms in the list below reported from an upstream NE
For troubleshooting instructions, refer to preceded alarms reported by NB/RSxxx: • 202056 - Loss Of Signal on Physical Link • 202057 - Loss Of Frame on Physical Link
LE-caused alarms and alarms caused by other NEs are handled accordingly.
After solving the problem which initiated the trigger alarm this error message will also be cleared.
If the fault cannot be cleared, contact the technical assistance center (TAC) to get support in isolating the fault. For suitable preparation save the error symptoms as described in “Collect Info for Assistance”. Log files need to be analyzed and specific measures must be taken which are out of the operator’s scope.
DN70580522 Issue 01A
225
Troubleshooting Node B 202060 - Remote Alarm Indication on Physical Link
Id:0900d80580228b91Confidential
162 202060 - Remote Alarm Indication on Physical Link
162.1 Failure Event Report
162.2 Error DescriptionRemote alarm indication (RAI) indication has been received on a physical link E1, J1, or T1 (according to reported MOC in the failure event report). Indicates that a problem has been detected downstream from the Node B on the physical link reporting the alarm. Reception from the Node B in that direction has probably been interrupted on this link. This may be due to faulty hardware at either end or problems on the transmission medium between the two ends.
This alarm is triggered by a preceded alarm from another downstream NE in the super-vision of the RC. If this NE is an NB/RSxxx, the following alarms may be the trigger: • 202056 - Loss Of Signal on Physical Link • 202057 - Loss Of Frame on Physical Link • 202058 - Loss Of Cell Delineation on Physical Link
Alternatively, an alarm from Link Equipment (LE, such as SDH/PDH multiplexers, ATM switches, or repeaters) in downstream direction may be the root cause, such as: • Loss Of Signal (LOS) • Loss Of Frame (LOF) • Alarm Indication Signal (AIS)
162.3 Troubleshooting (LMT)Because this error message is a consequence of a preceded alarm from a downstream NE in the supervision of the RC, the troubleshooting has to start with investigation of the trigger alarm.
As regards Node B PF2 alarms, find the relevant alarm in the list of the ALARM View window of the LMT:1. Click on the “Alarm View” button or use the shortkey Ctrl + A .2. Use the filter and sort function to concentrate on the relevant alarms
As regards any other NE in the supervision of the RC, find the relevant alarm in the list of the Alarm Monitoring Application:1. Select and open the icon “Alarm Monitoring” in the Application Launcher window
(double left-click)2. Look for one of the alarms in the list below reported from a downstream NE
Managed Object Class / Hardware Type:
E1TTP, J1TTP
Event Type: communicationsAlarm
Probable Cause: RemoteAlarmIndication
Severity: major
226 DN70580522Issue 01A
Troubleshooting Node B
Id:0900d80580228b91Confidential
202060 - Remote Alarm Indication on Physical Link
For troubleshooting instructions refer to one of the following preceded alarms reported by another NB/RSxxx: • 202056 - Loss Of Signal on Physical Link • 202057 - Loss Of Frame on Physical Link • 202058 - Loss Of Cell Delineation on Physical Link
LE-caused alarms and preceded alarms of other NEs are handled accordingly.
After solving the problem which initiated the trigger alarm this error message will also be cleared.
If the fault cannot be cleared, contact the technical assistance center (TAC) to get support in isolating the fault. For suitable preparation save the error symptoms as described in “Collect Info for Assistance”. Log files need to be analyzed and specific measures must be taken which are out of the operator’s scope.
DN70580522 Issue 01A
227
Troubleshooting Node B 202061 - Loss of Multi Frame Alarm Indication on E1Physical Link
Id:0900d8058022b7eeConfidential
163 202061 - Loss of Multi Frame Alarm Indica-tion on E1 Physical Link
163.1 Failure Event Report
163.2 Error DescriptionLoss of multi frame alarm (LOMF) indication has been received on an E1 physical link. This alarm indicates that multiframe synchronization has been lost on the E1 transport interface between the Node B and the next device upstream.
This may be due to: • Misconfiguration of the hardware at either end • Faulty hardware at either end • Problems on the transmission medium between the two ends
The “202061 - Loss of Multi Frame Alarm Indication on E1 Physical Link” alarm may be caused by the following:
The Node B's E1TTP managed object's attribute crcOperationMode, which indicates the mode of CRC operation, is set to its default value crcForced whereas the frame format for the RNC is set to 0 meaning that the CRC is disabled.
As a consequence of these settings, the E1TTP’s OST/AVS combination changes to disabled/failed.
If the Node B's E1TTP managed object's attribute crcOperationMode is set to crcAu-tomatic, however, the 202098 - CRC4 not used by FE reported on E1TTP alarm is output. Refer to the alarm’s error description and follow its troubleshooting.
163.3 Troubleshooting (LMT)Take the following measures to clear the alarm cause:1. Is there also an equipment alarm of the Core Controller (CC) in the reporting Node B
present?Using the ALARM View window of the LMT:– Click on the “Alarm View” button or use the shortcut key Ctrl + A
– Use the filter and sort function to concentrate on CC alarmsIf an equipment alarm of the CC is present try to fix this fault first which probably also eliminates the LOMF alarm.
2. Is the LE, which is connected to the relevant port, reporting an equipment alarm?– If an equipment alarm at the LE is present try to fix this fault first which probably
also eliminates the LOMF alarm.
Managed Object Class / Hardware Type:
E1TTP
Event Type: communicationsAlarm
Probable Cause: LossOfMultiFrame
Severity: major
228 DN70580522Issue 01A
Troubleshooting Node B
Id:0900d8058022b7eeConfidential
202061 - Loss of Multi Frame Alarm Indication on E1 Physical Link
3. Check the cable connection
– Take special care if an optical STM-1/OC-3 line is used (see warning above)– Proper connection at the LE (good contact, clean optical connector)– Proper connection at the Node B (good contact, clean optical connector)– Undamaged cable between Node B and LE respectively other Node B or RNC
4. Check the OVPT or IUBCONElectrical Iub lines (E1/J1/T1) are connected to the Node B using an OVPT (over-voltage protection and tracer module) equipped with surge arresters or an IUBCON (Iub connector). Both are available for coax and symmetrical cables.– Check surge arresters at OVPT and replace a defective one if necessary– Replace OVPT or IUBCON if any other reason could not be found.
Replacement must be done according to the “Replacing Node B Units” manual, “Tasklist”.
5. Configuration mismatchIs the configuration of the relevant ports at either end in accordance with each other?– For Node B use the LMT to upload the nbDatabase and analyze the settings for
the relevant port– For LE the appropriate local maintenance system has to be usedIf the misconfiguration can be identified as probable cause for the error report the alignment of the settings should clear the fault.
6. If none of the proposed actions results in a fault clearance contact the technical assistance center (TAC) to get support in isolating the fault. For suitable preparation save the error symptoms as described in “Collect Info for Assistance”. Log files need to be analyzed and specific measures must be taken which are out of the operator’s scope.
!WARNING: Radiation from laser devices (EN 60825/IEC 60825).
Damage of health may occur.
To avoid damage to health, you must observe the regulations regarding protection against radiation from laser devices (EN 60825/IEC 60825). • You must always use dedicated laser-protective goggles. • Never look into open fiber-optic cable ends, as this may damage your eyes.
DN70580522 Issue 01A
229
Troubleshooting Node B 202062 - Line Alarm Indication Signal Indication onSTM1 Physical Link
Id:0900d80580228b93Confidential
164 202062 - Line Alarm Indication Signal Indica-tion on STM1 Physical Link
164.1 Failure Event Report
164.2 Error DescriptionLine alarm indication signal (L-AIS) indication has been received on an STM-1/OC-3 physical link. This alarm indicates that a problem (e.g. LOS, LOF, LOP) has been detected upstream from the Node B (backward direction) on the STM-1/OC-3 link reporting the alarm. Transmission to the Node B from that direction has probably been interrupted on this link. The Node B forwards a VP AIS to the next NE in forward direc-tion (downstream). The VP AIS are forwarded by all downstream NEs until they reach the NE which terminates the link affected by the failure.
This alarm is triggered by a preceded alarm from another upstream NE in the supervi-sion of the RC. If this NE is an NB/RSxxx, the following alarms may be the trigger: • 202056 - Loss Of Signal on Physical Link • 202057 - Loss Of Frame on Physical Link • 202064 - Path Loss of Pointer Indication on STM1 Physical Link
Alternatively, an alarm from Link Equipment (LE, such as SDH/PDH multiplexers, ATM switches, or repeaters) in upstream direction may be the root cause, such as: • Loss Of Signal (LOS) • Loss Of Frame (LOF) • Loss Of Pointer (LOP)
Additionally, the L-AIS causes the reporting Node B’s system clock to switch in holdover mode, indicated by the 202506 - Node B system clock in holdover mode alarm.
164.3 Troubleshooting (LMT)Because this error message is a consequence of a preceded alarm from an upstream NE in the supervision of the RC, the troubleshooting has to start with investigation of the trigger alarm.
As regards Node B PF2 alarms, find the relevant alarm in the list of the ALARM View window of the LMT:1. Click on the “Alarm View” button or use the shortkey Ctrl + A .2. Use the filter and sort function to concentrate on the relevant alarms
Managed Object Class / Hardware Type:
Stm1TP
Event Type: communicationsAlarm
Probable Cause: AlarmIndicationSignal
Severity: major
230 DN70580522Issue 01A
Troubleshooting Node B
Id:0900d80580228b93Confidential
202062 - Line Alarm Indication Signal Indication on STM1 Physical Link
As regards any other NE in the supervision of the RC, find the relevant alarm in the list of the Alarm Monitoring Application:1. Select and open the icon “Alarm Monitoring” in the Application Launcher window
(double left-click)2. Look for one of the alarms in the list below reported from an upstreamNE
For troubleshooting instructions refer to the following preceded alarms reported by another NB/RSxxx: • 202056 - Loss Of Signal on Physical Link • 202057 - Loss Of Frame on Physical Link • 202064 - Path Loss of Pointer Indication on STM1 Physical Link
LE caused alarms and preceded alarms of other NEs are handled accordingly.
After solving the problem which initiated the trigger alarm this error message will also be cleared.
If the fault cannot be cleared, contact the technical assistance center (TAC) to get support in isolating the fault. For suitable preparation save the error symptoms as described in “Collect Info for Assistance”. Log files need to be analyzed and specific measures must be taken which are out of the operator’s scope.
DN70580522 Issue 01A
231
Troubleshooting Node B 202063 - Line Remote Defect Indication on STM1Physical Link
Id:0900d80580228b95Confidential
165 202063 - Line Remote Defect Indication on STM1 Physical Link
165.1 Failure Event Report
165.2 Error DescriptionLine remote defect indication (L-RDI) has been received on an STM-1/OC-3 physical link. The L-RDI indicates that a problem has been detected downstream from the Node B on the link reporting the alarm. In other words, L-RDI is used by the node termi-nating the link to inform the other terminating NE in the backward direction (upstream) about a failure that was detected in forward direction. Reception from the Node B in that direction has probably been interrupted on the reporting link.
The fault leading to this alarm may have been caused by faulty hardware at either end or problems on the transmission medium between the two ends.
This alarm is triggered by a preceded alarm from another downstream NE in the super-vision of the RC. If this NE is an NB/RSxxx, the following alarms may be the trigger: • 202056 - Loss Of Signal on Physical Link • 202057 - Loss Of Frame on Physical Link • 202064 - Path Loss of Pointer Indication on STM1 Physical Link
Alternatively, an alarm from Link Equipment (LE, such as SDH/PDH multiplexers, ATM switches, or repeaters) in downstream direction may be the root cause, such as: • Loss Of Signal (LOS) • Loss Of Frame (LOF) • Loss Of Pointer (LOP) • Alarm Indication Signal (AIS)
165.3 Troubleshooting (LMT)Because this error message is a consequence of a preceded alarm from a downstream NE in the supervision of the RC, the troubleshooting has to start with investigation of the trigger alarm.
As regards Node B PF2 alarms, find the relevant alarm in the list of the ALARM View window of the LMT:1. Click on the “Alarm View” button or use the shortkey Ctrl + A .2. Use the filter and sort function to concentrate on the relevant alarms
Managed Object Class / Hardware Type:
Stm1TP
Event Type: communicationsAlarm
Probable Cause: RemoteAlarmIndicator
Severity: major
232 DN70580522Issue 01A
Troubleshooting Node B
Id:0900d80580228b95Confidential
202063 - Line Remote Defect Indication on STM1 Physical Link
As regards any other NE in the supervision of the RC, find the relevant alarm in the list of the Alarm Monitoring Application:1. Select and open the icon “Alarm Monitoring” in the Application Launcher window
(double left-click)2. Look for one of the alarms in the list below reported from a downstream NE
For troubleshooting instructions refer to one of the following preceded alarms reported by another NB/RSxxx: • 202056 - Loss Of Signal on Physical Link • 202057 - Loss Of Frame on Physical Link • 202064 - Path Loss of Pointer Indication on STM1 Physical Link
LE-caused alarms and preceded alarms of other NEs are handled accordingly.
After solving the problem which initiated the trigger alarm this error message will also be cleared.
If the fault cannot be cleared, contact the technical assistance center (TAC) to get support in isolating the fault. For suitable preparation save the error symptoms as described in “Collect Info for Assistance”. Log files need to be analyzed and specific measures must be taken which are out of the operator’s scope.
DN70580522 Issue 01A
233
Troubleshooting Node B 202064 - Path Loss of Pointer Indication on STM1Physical Link
Id:0900d80580228b97Confidential
166 202064 - Path Loss of Pointer Indication on STM1 Physical Link
166.1 Failure Event Report
166.2 Error DescriptionPath loss of pointer (P-LOP) indication has been received on an STM-1/OC-3 physical link. The pointer enables the STM-1/OC-3 device on the Node B to locate the payload within the signal. If the Node B STM-1/OC-3 interface has received an invalid path pointer, it will declare a loss of pointer condition. Because the STM-1/OC-3 interface cannot determine where the payload starts, all downstream traffic will be lost as long as the condition persists. This may be due to faulty hardware at either end or problems on the transmission medium between the two ends.
The path loss of pointer may be the root cause for alarms indicated by different NEs in the supervision of the RC. If this NE is an NB/RSxxx, the following subsequent alarms may be output: • Downstream direction:
202065 - Path Alarm Indication Signal on STM1 Physical Link • Upstream direction:
202066 - Path Remote Defect Indication on STM1 Physical Link
166.3 fcTroubleshooting (LMT)1. Is there also an equipment alarm of the Core Controller (CC) in the reporting Node B
present?Using the ALARM View window of the LMT:– Click on the “Alarm View” button or use the shortcut key Ctrl + A
– Use the filter and sort function to concentrate on CC alarmsIf an equipment alarm of the CC is present try to fix this fault first which probably also eliminates the P-LOP alarm.
2. Is the LE, which is connected to the relevant port, reporting an equipment alarm?– If an equipment alarm at the LE is present try to fix this fault first which probably
also eliminates the P-LOP alarm.
Managed Object Class / Hardware Type:
Stm1TP
Event Type: communicationsAlarm
Probable Cause: LossOfPointer
Severity: major
234 DN70580522Issue 01A
Troubleshooting Node B
Id:0900d80580228b97Confidential
202064 - Path Loss of Pointer Indication on STM1 Physical Link
3. Check the cable connection
– Take special care if an optical STM-1/OC-3 line is used (see warning above)– Proper connection at the LE (good contact, clean optical connector)– Proper connection at the Node B (good contact, clean optical connector)– Undamaged cable between Node B and LE respectively other Node B or RNC
4. Check the OVPT or IUBCONElectrical Iub lines (E1/J1/T1) are connected to the Node B using an OVPT (over-voltage protection and tracer module) equipped with surge arresters or an IUBCON (Iub connector). Both are available for coax and symmetrical cables.– Check surge arresters at OVPT and replace a defective one if necessary– Replace OVPT or IUBCON if any other reason could not be found. Replacement
must be done according to the “Replacing Node B Units” instructions.5. If none of the proposed actions results in a fault clearance contact the technical
assistance center (TAC) to get support in isolating the fault. For suitable preparation save the error symptoms as described in “Collect Info for Assistance”. Log files need to be analyzed and specific measures must be taken which are out of the operator’s scope.
!WARNING: Radiation from laser devices (EN 60825/IEC 60825).
Damage of health may occur.
To avoid damage to health, you must observe the regulations regarding protection against radiation from laser devices (EN 60825/IEC 60825). • You must always use dedicated laser-protective goggles. • Never look into open fiber-optic cable ends, as this may damage your eyes.
DN70580522 Issue 01A
235
Troubleshooting Node B 202065 - Path Alarm Indication Signal on STM1 Physi-cal Link
Id:0900d80580228b99Confidential
167 202065 - Path Alarm Indication Signal on STM1 Physical Link
167.1 Failure Event Report
167.2 Error DescriptionA Path Alarm Indication Signal (P-AIS) has been received on an STM-1/OC-3 physical link. In other words, the value 1 was received for three times consecutively at all relevant pointer bytes. The mismatch may be caused by an incorrect configuration at the trans-mitting end.
AIS is used to inform the neighboring NE in forward direction (downstream) about a failure that was detected in in backward direction (upstream). AIS are forwarded by all NEs until they reach the NE which terminates the link that is affected by the failure.
The P-AIS indicates the following: • At least one of the following problems has been detected upstream from the Node B
on the STM-1/OC-3 link reporting this alarm:– Loss of Signal (LOS)– Loss of Frame (LOF)– Path Loss of Pointer (P-LOP)
• Transmission from upstream direction to the Node B has probably been interrupted on the reporting link.
The “202065 - Path Alarm Indication Signal on STM1 Physical Link” alarm may be trig-gered by a preceded alarm reported by another upstream NE in the supervision of the RC. If this NE is an NB/RSxxx, the following alarms may be the trigger: • 202056 - Loss Of Signal on Physical Link • 202057 - Loss Of Frame on Physical Link • 202064 - Path Loss of Pointer Indication on STM1 Physical Link
Alternatively, an alarm from link equipment (LE, such as SDH/PDH multiplexers, ATM switches, or repeaters) in upstream direction may be the root cause: • Loss Of Signal (LOS) • Loss Of Frame (LOF) • Loss Of Pointer (LOP)
Managed Object Class / Hardware Type:
Stm1TP
Event Type: communicationAlarm
Probable Cause: AlarmIndicationSignal
Severity: major
236 DN70580522Issue 01A
Troubleshooting Node B
Id:0900d80580228b99Confidential
202065 - Path Alarm Indication Signal on STM1 Physi-cal Link
167.3 Troubleshooting (LMT)Because this error message is a consequence of a preceded alarm from an upstream NE in the supervision of the RC, the troubleshooting has to start with investigation of the trigger alarm.
As regards Node B PF2 alarms, find the relevant alarm in the list of the ALARM View window of the LMT:1. Click on the “Alarm View” button or use the shortkey Ctrl + A .2. Use the filter and sort function to concentrate on the relevant alarms
As regards any other NE in the supervision of the RC, find the relevant alarm in the list of the Alarm Monitoring Application:1. Select and open the icon “Alarm Monitoring” in the Application Launcher window
(double left-click)2. Look for one of the alarms in the list below reported from an upstream NE
For troubleshooting instructions refer to one of the following preceded alarms, reported by another NB/RSxxx: • 202056 - Loss Of Signal on Physical Link • 202057 - Loss Of Frame on Physical Link • 202064 - Path Loss of Pointer Indication on STM1 Physical Link
Alarms caused by LE or other NEs are handled accordingly.
After having solved the problem which initiated the trigger alarm, this error message will also be cleared.
If the fault could not be cleared yet, contact the technical assistance center (TAC) to get support in isolating the fault. For suitable preparation save the error symptoms as described in “Collect Info for Assistance”. Log files need to be analyzed and specific measures must be taken which are out of the operator’s scope.
DN70580522 Issue 01A
237
Troubleshooting Node B 202066 - Path Remote Defect Indication on STM1Physical Link
Id:0900d80580228b9bConfidential
168 202066 - Path Remote Defect Indication on STM1 Physical Link
168.1 Failure Event Report
168.2 Error DescriptionA Path Remote Defect Indication (P-RDI) indication has been received on the reporting STM-1/OC-3 physical link. The mismatch may be caused by an incorrect configuration at the transmitting end.
RDI is used by the node terminating the link to inform the other terminating NE in the backward (upstream) direction about a failure that was detected in forward (down-stream) direction.
The P-RDI indicates the following: • At least one of the following problems has been detected downsteam from the
Node B on the STM-1/OC-3 link reporting this alarm:– Loss of Signal (LOS)– Loss of Frame (LOF)– Path Loss of Pointer (P-LOP)
• Transmission in downstream direction of the Node B has probably been interrupted on the reporting link.
The “202066 - Path Remote Defect Indication on STM1 Physical Link” alarm may be trig-gered by a preceded alarm, reported by another downsteam NE in the supervision of the RC. If this NE is an NB/RSxxx, the following alarms may be the trigger: • 202056 - Loss Of Signal on Physical Link • 202057 - Loss Of Frame on Physical Link • 202064 - Path Loss of Pointer Indication on STM1 Physical Link
Alternatively, an alarm from link equipment (LE, such as SDH/PDH multiplexers, ATM switches, or repeaters) in downstream direction may be the root cause, such as: • Loss Of Signal (LOS) • Loss Of Frame (LOF) • Loss Of Pointer (LOP)
168.3 Troubleshooting (LMT)Because this error message is a consequence of a preceded alarm from a downstream NE in the supervision of the RC, the troubleshooting has to start with investigation of the trigger alarm.
Managed Object Class / Hardware Type:
Stm1TP
Event Type: communicationsAlarm
Probable Cause: RemoteAlarmIndication
Severity: major
238 DN70580522Issue 01A
Troubleshooting Node B
Id:0900d80580228b9bConfidential
202066 - Path Remote Defect Indication on STM1 Physical Link
As regards Node B PF2 alarms, find the relevant alarm in the list of the ALARM View window of the LMT:1. Click on the “Alarm View” button or use the shortkey Ctrl + A .2. Use the filter and sort function to concentrate on the relevant alarms
As regards any other NE in the supervision of the RC, find the relevant alarm in the list of the Alarm Monitoring Application:1. Select and open the icon “Alarm Monitoring” in the Application Launcher window
(double left-click)2. Look for one of the alarms in the list below reported from a downstream NE
For troubleshooting instructions refer to one of the following preceded alarms, reported by another NB/RSxxx: • 202056 - Loss Of Signal on Physical Link • 202057 - Loss Of Frame on Physical Link • 202064 - Path Loss of Pointer Indication on STM1 Physical Link
Alarms caused by LE or by other NEs are handled accordingly.
After having solved the problem which initiated the trigger alarm, this error message will also be cleared.
If the fault could not be cleared yet, contact the technical assistance center (TAC) to get support in isolating the fault. For suitable preparation save the error symptoms as described in “Collect Info for Assistance”. Log files need to be analyzed and specific measures must be taken which are out of the operator’s scope.
DN70580522 Issue 01A
239
Troubleshooting Node B 202068 - Signal Label Mismatch Indication on STM1Physical Link
Id:0900d8058022b814Confidential
169 202068 - Signal Label Mismatch Indication on STM1 Physical Link
169.1 Failure Event Report
169.2 Error DescriptionSignal label mismatch (SLM) indication has been received on an STM-1/OC-3 physical link. This may be because of corruptions on the STM-1/OC-3 line or incorrect configu-ration at the transmitting end.
169.3 Troubleshooting (LMT)Is the configuration of the relevant ports at either end in accordance with each other? • For Node B use the LMT to upload the nbDatabase and analyze the settings for the
relevant port • For LE the appropriate local maintenance system has to be used
If the misconfiguration can be identified as probable cause for the error report the align-ment of the settings should clear the fault.
If none of the proposed actions results in a fault clearance contact the technical assis-tance center (TAC) to get support in isolating the fault. For suitable preparation save the error symptoms as described in “Collect Info for Assistance”. Log files need to be analyzed and specific measures must be taken which are out of the operator’s scope.
Managed Object Class / Hardware Type:
Stm1TP
Event Type: communicationsAlarm
Probable Cause: SignalLabelMismatch
Severity: minor
240 DN70580522Issue 01A
Troubleshooting Node B
Id:0900d8058022b81cConfidential
202070 - Signal Degrade Indication on STM1 Physical Link
170 202070 - Signal Degrade Indication on STM1 Physical Link
170.1 Failure Event Report
170.2 Error DescriptionSignal degrade (SD) indication has been received on an STM-1/OC-3 physical link. This indicates that the bit error rate on the received STM-1/OC-3 signal has exceeded the threshold set in the signalDegradeThreshold configuration attribute. This may be due to faulty hardware at either end or problems on the transmission medium between the two ends.
170.3 Troubleshooting (LMT)Take the following measures to clear the alarm cause:1. Is there also an equipment alarm of the Core Controller (CC) in the reporting Node B
present?Using the ALARM View window of the LMT:– Click on the “Alarm View” button or use the shortcut key Ctrl + A
– Use the filter and sort function to concentrate on CC alarmsIf an equipment alarm of the CC is present try to fix this fault first which probably also eliminates the SD alarm.
2. Is the LE, which is connected to the relevant port, reporting an equipment alarm?– If an equipment alarm at the LE is present try to fix this fault first which probably
also eliminates the SD alarm.3. Check the cable connection
– Take special care if an optical STM-1/OC-3 line is used (see warning above)– Proper connection at the LE (good contact, clean optical connector)– Proper connection at the Node B (good contact, clean optical connector)– Undamaged cable between Node B and LE respectively other Node B or RNC
Managed Object Class / Hardware Type:
Stm1TP
Event Type: communicationsAlarm
Probable Cause: DegradedSignal
Severity: minor
!WARNING: Radiation from laser devices (EN 60825/IEC 60825).
Damage of health may occur.
To avoid damage to health, you must observe the regulations regarding protection against radiation from laser devices (EN 60825/IEC 60825). • You must always use dedicated laser-protective goggles. • Never look into open fiber-optic cable ends, as this may damage your eyes.
DN70580522 Issue 01A
241
Troubleshooting Node B 202070 - Signal Degrade Indication on STM1 PhysicalLink
Id:0900d8058022b81cConfidential
4. Check the OVPT or IUBCONElectrical Iub lines (E1/J1/T1) are connected to the Node B using an OVPT (over-voltage protection and tracer module) equipped with surge arresters or an IUBCON (Iub connector). Both are available for coax and symmetrical cables.– Check surge arresters at OVPT and replace a defective one if necessary– Replace OVPT or IUBCON if any other reason could not be found.
Replacement must be done according to the “Replacing Node B Units” manual, “Tasklist”.
5. If none of the proposed actions results in a fault clearance contact the technical assistance center (TAC) to get support in isolating the fault. For suitable preparation save the error symptoms as described in “Collect Info for Assistance”. Log files need to be analyzed and specific measures must be taken which are out of the operator’s scope.
242 DN70580522Issue 01A
Troubleshooting Node B
Id:0900d8058022b824Confidential
202071 - Excessive Bit Error Rate Indication on STM1 Physical Link
171 202071 - Excessive Bit Error Rate Indication on STM1 Physical Link
171.1 Failure Event Report
171.2 Error DescriptionExcessive bit error rate (EBER) indication has been received on an STM-1/OC-3 physical link. This indicates that the bit error rate on the received STM-1/OC-3 signal has exceeded the threshold set in the signalFailThreshold configuration attribute. This may be due to faulty hardware at either end or problems on the transmission medium between the two ends.
171.3 Troubleshooting (LMT)Take the following measures to clear the alarm cause:1. Is there also an equipment alarm of the Core Controller (CC) in the reporting Node B
present?Using the ALARM View window of the LMT:– Click on the “Alarm View” button or use the shortcut key Ctrl + A
– Use the filter and sort function to concentrate on CC alarmsIf an equipment alarm of the CC is present try to fix this fault first which probably also eliminates the EBER alarm.
2. Is the LE, which is connected to the relevant port, reporting an equipment alarm?– If an equipment alarm at the LE is present try to fix this fault first which probably
also eliminates the EBER alarm.3. Check the cable connection
– Take special care if an optical STM-1/OC-3 line is used (see warning above)– Proper connection at the LE (good contact, clean optical connector)– Proper connection at the Node B (good contact, clean optical connector)– Undamaged cable between Node B and LE respectively other Node B or RNC
Managed Object Class / Hardware Type:
Stm1TP
Event Type: communicationsAlarm
Probable Cause: ExcessiveBER
Severity: major
!WARNING: Radiation from laser devices (EN 60825/IEC 60825).
Damage of health may occur.
To avoid damage to health, you must observe the regulations regarding protection against radiation from laser devices (EN 60825/IEC 60825). • You must always use dedicated laser-protective goggles. • Never look into open fiber-optic cable ends, as this may damage your eyes.
DN70580522 Issue 01A
243
Troubleshooting Node B 202071 - Excessive Bit Error Rate Indication on STM1Physical Link
Id:0900d8058022b824Confidential
4. Check the OVPT or IUBCONElectrical Iub lines (E1/J1/T1) are connected to the Node B using an OVPT (over-voltage protection and tracer module) equipped with surge arresters or an IUBCON (Iub connector). Both are available for coax and symmetrical cables.– Check surge arresters at OVPT and replace a defective one if necessary– Replace OVPT or IUBCON if any other reason could not be found.
Replacement must be done according to the “Replacing Node B Units” manual, “Tasklist”.
5. If none of the proposed actions results in a fault clearance contact the technical assistance center (TAC) to get support in isolating the fault. For suitable preparation save the error symptoms as described in “Collect Info for Assistance”. Log files need to be analyzed and specific measures must be taken which are out of the operator’s scope.
244 DN70580522Issue 01A
Troubleshooting Node B
Id:0900d80580228b9dConfidential
202072 - Alarm Indication Signal on an ATM VC
172 202072 - Alarm Indication Signal on an ATM VC
172.1 Failure Event Report
172.2 Error DescriptionAn alarm indication signal (AIS) has been received on an ATM VC. The ATM cell stream on the affected VC will probably have been interrupted.
AIS indicates that another NE upstream (backward direction) from the Node B detected an alarm condition and thus sent the AIS. The alarm indication signal is used to inform neighboring NE in forward direction (downstream) about the alarm condition. AIS are then forwarded by all NEs in downstream direction until they reach the NE which termi-nates the link that is affected by the failure.
This alarm is triggered by a preceded alarms from another upstream NE in the supervi-sion of the RC. If this NE is an NB/RSxxx, the following alarms may be the trigger: • 202056 - Loss Of Signal on Physical Link • 202057 - Loss Of Frame on Physical Link • 202058 - Loss Of Cell Delineation on Physical Link
Alternatively, an alarm from Link Equipment (LE, such as SDH/PDH multiplexers, ATM switches, or repeaters) in upstream direction may be the root cause, such as: • Loss Of Signal (LOS) • Loss Of Frame (LOF)
172.3 Troubleshooting (LMT)Because this error message is a consequence of a preceded alarm from an upstream NE in the supervision of the RC, the troubleshooting has to start with investigation of the trigger alarm.
As regards Node B PF2 alarms, find the relevant alarm in the list of the ALARM View window of the LMT:1. Click on the “Alarm View” button or use the shortkey Ctrl + A .2. Use the filter and sort function to concentrate on the relevant alarms
As regards any other NE in the supervision of the RC, find the relevant alarm in the list of the Alarm Monitoring Application:1. Select and open the icon “Alarm Monitoring” in the Application Launcher window
(double left-click)2. Look for one of the alarms in the list below reported from an upstream NE
Managed Object Class / Hardware Type:
VcTTP
Event Type: communicationsAlarm
Probable Cause: AlarmIndicationSignal
Severity: minor
DN70580522 Issue 01A
245
Troubleshooting Node B 202072 - Alarm Indication Signal on an ATM VC
Id:0900d80580228b9dConfidential
For troubleshooting instructions refer to one of the following preceded alarms, reported by another NB/RSxxx: • 202056 - Loss Of Signal on Physical Link • 202057 - Loss Of Frame on Physical Link • 202058 - Loss Of Cell Delineation on Physical Link
LE-caused alarms and alarms reported by other NEs are handled accordingly.
After solving the problem which initiated the trigger alarm this error message will also be cleared.
If the fault cannot be cleared, contact the technical assistance center (TAC) to get support in isolating the fault. For suitable preparation save the error symptoms as described in “Collect Info for Assistance”. Log files need to be analyzed and specific measures must be taken which are out of the operator’s scope.
246 DN70580522Issue 01A
Troubleshooting Node B
Id:0900d80580228b9fConfidential
202073 - Remote Defect Indication on an ATM VC
173 202073 - Remote Defect Indication on an ATM VC
173.1 Failure Event Report
173.2 Error DescriptionA remote defect indication (RDI) indication has been received on an ATM VC. The ATM cell stream on the affected VC will probably have been interrupted.
RDI is used by the node terminating the link to inform the other terminating NE in the backward (upstream) direction about a failure that was detected in forward (down-stream) direction.
This alarm is triggered by a preceded alarm from another downstream NE in the super-vision of the RC. If this NE is an NB/RSxxx, the following alarms may be the trigger: • 202056 - Loss Of Signal on Physical Link • 202057 - Loss Of Frame on Physical Link • 202058 - Loss Of Cell Delineation on Physical Link
Alternatively, an alarm from Link Equipment (LE, such as SDH/PDH multiplexers, ATM switches, or repeaters) in downstream direction may be the root cause, such as: • Loss Of Signal (LOS) • Loss Of Frame (LOF) • Alarm Indication Signal (AIS)
173.3 Troubleshooting (LMT)Because this error message is a consequence of a preceded alarm from an upstream NE the troubleshooting has to start with investigation of the trigger alarm. Find the relevant alarm in the list of the ALARM View window of the LMT:1. Click on the “Alarm View” button or use the shortkey Ctrl + A .2. Use the filter and sort function to concentrate on the relevant alarms
For troubleshooting instructions refer to one of the following preceded alarms, reported by another NB/RSxxx: • 202056 - Loss Of Signal on Physical Link • 202057 - Loss Of Frame on Physical Link • 202058 - Loss Of Cell Delineation on Physical Link
LE-caused alarms and alarms cause by other NEs are handled accordingly.
After solving the problem which initiated the trigger alarm this error message will also be cleared.
Managed Object Class / Hardware Type:
VcTTP
Event Type: communicationsAlarm
Probable Cause: RemoteAlarmIndication
Severity: minor
DN70580522 Issue 01A
247
Troubleshooting Node B 202073 - Remote Defect Indication on an ATM VC
Id:0900d80580228b9fConfidential
If the fault cannot be cleared, contact the technical assistance center (TAC) to get support in isolating the fault. For suitable preparation save the error symptoms as described in “Collect Info for Assistance”. Log files need to be analyzed and specific measures must be taken which are out of the operator’s scope.
248 DN70580522Issue 01A
Troubleshooting Node B
Id:0900d8058022b838Confidential
202074 - SSCOP Failure Indication on an ATM VC used by ALCAP or NBAP
174 202074 - SSCOP Failure Indication on an ATM VC used by ALCAP or NBAP
174.1 Failure Event Report
174.2 Error DescriptionA SAAL failure has been received on an ATM VC used for ALCAP or NBAP signaling. This may be only a temporary failure from which the link will have recovered by itself (e.g. by automatic retransmission). Persistent reports of this kind may be due to hardware or software failure at either end or problems on the transmission medium between the two ends.
174.3 Troubleshooting (LMT)Take the following measures to clear the alarm cause:1. Is there also an equipment alarm of the Core Controller (CC) in the reporting Node B
present?Using the ALARM View window of the LMT:– Click on the “Alarm View” button or use the shortcut key Ctrl + A
– Use the filter and sort function to concentrate on CC alarmsIf an equipment alarm of the CC is present try to fix this fault first which probably also eliminates this alarm.
2. Is the LE, which is connected to the relevant port, reporting an equipment alarm?– If an equipment alarm at the LE is present try to fix this fault first which probably
also eliminates this alarm.3. Check the cable connection
– Take special care if an optical STM-1/OC-3 line is used (see warning above)– Proper connection at the LE (good contact, clean optical connector)– Proper connection at the Node B (good contact, clean optical connector)– Undamaged cable between Node B and LE respectively other Node B or RNC
Managed Object Class / Hardware Type:
VcTTP
Event Type: communicationsAlarm
Probable Cause: SscopFailure
Severity: warning
!WARNING: Radiation from laser devices (EN 60825/IEC 60825).
Damage of health may occur.
To avoid damage to health, you must observe the regulations regarding protection against radiation from laser devices (EN 60825/IEC 60825). • You must always use dedicated laser-protective goggles. • Never look into open fiber-optic cable ends, as this may damage your eyes.
DN70580522 Issue 01A
249
Troubleshooting Node B 202074 - SSCOP Failure Indication on an ATM VCused by ALCAP or NBAP
Id:0900d8058022b838Confidential
4. Check the OVPT or IUBCONElectrical Iub lines (E1/J1/T1) are connected to the Node B using an OVPT (over-voltage protection and tracer module) equipped with surge arresters or an IUBCON (Iub connector). Both are available for coax and symmetrical cables.– Check surge arresters at OVPT and replace a defective one if necessary– Replace OVPT or IUBCON if any other reason could not be found.
Replacement must be done according to the “Replacing Node B Units” manual, “Tasklist”.
5. If none of the proposed actions results in a fault clearance contact the technical assistance center (TAC) to get support in isolating the fault. For suitable preparation save the error symptoms as described in “Collect Info for Assistance”. Log files need to be analyzed and specific measures must be taken which are out of the operator’s scope.
250 DN70580522Issue 01A
Troubleshooting Node B
Id:0900d80580228ba1Confidential
202075 - Alarm Indication Signal on an ATM VP
175 202075 - Alarm Indication Signal on an ATM VP
175.1 Failure Event Report
175.2 Error DescriptionAn alarm indication signal (AIS) indication has been received on an ATM VP. The ATM cell stream on the affected VP will probably have been interrupted.
AIS indicates that another NE upstream (backward direction) from the Node B detected an alarm condition and thus sent the AIS. The alarm indication signal is used to inform neighboring NE in forward direction (downstream) about the alarm condition. AIS are then forwarded by all NEs in downstream direction until they reach the NE which termi-nates the link that is affected by the failure.
This alarm is triggered by a preceded alarm from another upstream NE in the supervi-sion of the RC. If this NE is an NB/RSxxx, the following alarms may be trigger: • 202056 - Loss Of Signal on Physical Link • 202057 - Loss Of Frame on Physical Link • 202058 - Loss Of Cell Delineation on Physical Link
Alternatively, an alarm from Link Equipment (LE, such as SDH/PDH multiplexers, ATM switches, or repeaters) in upstream direction may be the root cause, such as: • Loss Of Signal (LOS) • Loss Of Frame (LOF)
175.3 Troubleshooting (LMT)Because this error message is a consequence of a preceded alarm from an upstream NE in the supervision of the RC, the troubleshooting has to start with investigation of the trigger alarm.
As regards Node B PF2 alarms, find the relevant alarm in the list of the ALARM View window of the LMT:1. Click on the “Alarm View” button or use the shortkey Ctrl + A .2. Use the filter and sort function to concentrate on the relevant alarms
As regards any other NE in the supervision of the RC, find the relevant alarm in the list of the Alarm Monitoring Application:1. Select and open the icon “Alarm Monitoring” in the Application Launcher window
(double left-click)2. Look for one of the alarms in the list below reported from an upstream NE
Managed Object Class / Hardware Type:
VpTTP
Event Type: communicationsAlarm
Probable Cause: AlarmIndicationSignal
Severity: minor
DN70580522 Issue 01A
251
Troubleshooting Node B 202075 - Alarm Indication Signal on an ATM VP
Id:0900d80580228ba1Confidential
For troubleshooting instructions refer to one of the following preceded alarms, reported by another NB/RSxxx: • 202056 - Loss Of Signal on Physical Link • 202057 - Loss Of Frame on Physical Link • 202058 - Loss Of Cell Delineation on Physical Link
LE-caused alarms and alarms caused by other NEs are handled accordingly.
After solving the problem which initiated the trigger alarm this error message will also be cleared.
If the fault cannot be cleared, contact the technical assistance center (TAC) to get support in isolating the fault. For suitable preparation save the error symptoms as described in “Collect Info for Assistance”. Log files need to be analyzed and specific measures must be taken which are out of the operator’s scope.
252 DN70580522Issue 01A
Troubleshooting Node B
Id:0900d80580228ba3Confidential
202076 - Remote Defect Indication on an ATM VP
176 202076 - Remote Defect Indication on an ATM VP
176.1 Failure Event Report
176.2 Error DescriptionA remote defect indication (RDI) indication has been received on an ATM VP. The ATM cell stream on the affected VP will probably have been interrupted.
RDI is used by the node terminating the link to inform the other terminating NE in the backward (upstream) direction about a failure that was detected in forward (down-stream) direction.
This alarm is triggered by a preceded alarm from another downstream NE in the super-vision of the RC. If this NE is an NB/RSxxx, the following alarms may be the trigger: • 202056 - Loss Of Signal on Physical Link • 202057 - Loss Of Frame on Physical Link • 202058 - Loss Of Cell Delineation on Physical Link
Alternatively, an alarm from Link Equipment (LE, such as SDH/PDH multiplexers, ATM switches, or repeaters) in downstream direction may be the root cause, such as: • Loss Of Signal (LOS) • Loss Of Frame (LOF) • Alarm Indication Signal (AIS)
176.3 Troubleshooting (LMT)Because this error message is a consequence of a preceded alarm from a downstream NE in the supervision of the RC, the troubleshooting has to start with investigation of the trigger alarm.
As regards Node B PF2 alarms, find the relevant alarm in the list of the ALARM View window of the LMT:1. Click on the “Alarm View” button or use the shortkey Ctrl + A .2. Use the filter and sort function to concentrate on the relevant alarms
As regards any other NE in the supervision of the RC, find the relevant alarm in the list of the Alarm Monitoring Application:1. Select and open the icon “Alarm Monitoring” in the Application Launcher window
(double left-click)2. Look for one of the alarms in the list below reported from a downstream NE
Managed Object Class / Hardware Type:
VpTTP
Event Type: communicationsAlarm
Probable Cause: RemoteAlarmIndication
Severity: minor
DN70580522 Issue 01A
253
Troubleshooting Node B 202076 - Remote Defect Indication on an ATM VP
Id:0900d80580228ba3Confidential
For troubleshooting instructions refer to one of the following preceded alarms, reported by another NB/RSxxx: • 202056 - Loss Of Signal on Physical Link • 202057 - Loss Of Frame on Physical Link • 202058 - Loss Of Cell Delineation on Physical Link
LE-caused alarms and alarms reported by other NEs are handled accordingly.
After solving the problem which initiated the trigger alarm this error message will also be cleared.
If the fault cannot be cleared, contact the technical assistance center (TAC) to get support in isolating the fault. For suitable preparation save the error symptoms as described in “Collect Info for Assistance”. Log files need to be analyzed and specific measures must be taken which are out of the operator’s scope.
254 DN70580522Issue 01A
Troubleshooting Node B
Id:0900d8058022b84aConfidential
202077 - ALCAP PVC Out Of Service Indication
177 202077 - ALCAP PVC Out Of Service Indica-tion
177.1 Failure Event Report
177.2 Error DescriptionThe signaling protocol (STC) used by ALCAP has indicated that the connection is out of service. This may be due to traffic congestion or a failure in the network or because the far end is not configured. STC will repeatedly attempt to reconnect and will indicate when the connection is in service.
177.3 Troubleshooting (LMT)Contact the technical assistance center (TAC) to get support in isolating the fault. For suitable preparation save the error symptoms as described in “Collect Info for Assis-tance”. Log files need to be analyzed and specific measures must be taken which are out of the operator’s scope.
Managed Object Class / Hardware Type:
VcTTP
Event Type: equipmentAlarm
Probable Cause: LinkFailure
Severity: major
DN70580522 Issue 01A
255
Troubleshooting Node B 202078 - Loss Of Delay Synchronization on IMA Link
Id:0900d8058022b850Confidential
178 202078 - Loss Of Delay Synchronization on IMA Link
178.1 Failure Event Report
178.2 Error Descriptiong NOTE
If an IMA group has been configured, however, not being operational during start-up, the Node B possibly restarts some minutes after start-up.
A loss of delay synchronization (LODS) defect is reported when the link differential delay between the link and the other links in the group is over the tolerable link differential delay (as defined by the configuration attribute imaGroupDiffDelayMax). If this alarm occurs then the ImaGroup will automatically cease transmitting on the link and (assum-ing that there are sufficient good links for the Group to remain Operational) continue to operate using the remaining good links.
178.3 Troubleshooting (LMT)Contact the technical assistance center (TAC) to get support in isolating the fault. For suitable preparation save the error symptoms as described in “Collect Info for Assis-tance”. Log files need to be analyzed and specific measures must be taken which are out of the operator’s scope.
Managed Object Class / Hardware Type:
ImaLink
Event Type: communicationsAlarm
Probable Cause: VendorSpecific
Severity: minor
256 DN70580522Issue 01A
Troubleshooting Node B
Id:0900d8058022b856Confidential
202079 - Loss Of IMA Frame on IMA Link
179 202079 - Loss Of IMA Frame on IMA Link
179.1 Failure Event Report
179.2 Error Descriptiong NOTE
If an IMA group has been configured, however, not being operational during start-up, the Node B possibly restarts some minutes after start-up.
The LIF (Loss of IMA Frame) defect is the occurrence of persistent OIF (Out of IMA Frame) anomalies for at least 2 IMA frames. This indicates that the IMA Frame synchro-nisation has been lost. If this alarm occurs then the ImaGroup will automatically cease transmitting on the link and (assuming that there are sufficient good links for the Group to remain Operational) continue to operate using the remaining good links.
179.3 Troubleshooting (LMT)Contact the technical assistance center (TAC) to get support in isolating the fault. For suitable preparation save the error symptoms as described in “Collect Info for Assis-tance”. Log files need to be analyzed and specific measures must be taken which are out of the operator’s scope.
Managed Object Class / Hardware Type:
ImaLink
Event Type: communicationsAlarm
Probable Cause: VendorSpecific
Severity: minor
DN70580522 Issue 01A
257
Troubleshooting Node B 202080 - Remote Failure Indicator on IMA Link
Id:0900d8058022b85cConfidential
180 202080 - Remote Failure Indicator on IMA Link
180.1 Failure Event Report
180.2 Error DescriptionPersistence of an RDI-IMA defect at the near end (NE). An RDI-IMA is when one of the available remote defect indicators (including IMA link specific defect) is indicated in the link related Link Information field. This indicates that the IMA Link at the far end has detected a defect and has reported it to the near end. If this alarm occurs then the ImaGroup will automatically cease transmitting on the link and (assuming that there are sufficient good links for the Group to remain Operational) continue to operate using the remaining good links.
180.3 Troubleshooting (LMT)Contact the technical assistance center (TAC) to get support in isolating the fault. For suitable preparation save the error symptoms as described in “Collect Info for Assis-tance”. Log files need to be analyzed and specific measures must be taken which are out of the operator’s scope.
Managed Object Class / Hardware Type:
ImaLink
Event Type: communicationsAlarm
Probable Cause: VendorSpecific
Severity: minor
258 DN70580522Issue 01A
Troubleshooting Node B
Id:0900d8058022b864Confidential
202081 - IMA Tx link is detected as mis-connected
181 202081 - IMA Tx link is detected as mis-con-nected
181.1 Failure Event Report
181.2 Error DescriptionTX link is detected as mis-connected. This is reported when the IMA unit has determined that the Tx link is not connected to the same far end (FE) IMA unit as the other TX links in the group. This condition will be detected by the Test Pattern Procedure.
181.3 Troubleshooting (LMT)Check the cable connections.
Managed Object Class / Hardware Type:
ImaLink
Event Type: communicationsAlarm
Probable Cause: VendorSpecific
Severity: minor
DN70580522 Issue 01A
259
Troubleshooting Node B 202082 - IMA Rx link is detected as mis-connected
Id:0900d8058022b86cConfidential
182 202082 - IMA Rx link is detected as mis-con-nected
182.1 Failure Event Report
182.2 Error DescriptionRX link is detected as mis-connected. This is reported when the IMA unit has deter-mined that the Rx link is not connected to the same far end (FE) IMA unit as the other Rx links in the group. This condition will be detected by the Test Pattern Procedure.
182.3 Troubleshooting (LMT)Check the cable connections.
Managed Object Class / Hardware Type:
ImaLink
Event Type: communicationsAlarm
Probable Cause: VendorSpecific
Severity: minor
260 DN70580522Issue 01A
Troubleshooting Node B
Id:0900d8058022b872Confidential
202083 - Tx fault declared at the NE on IMA Link
183 202083 - Tx fault declared at the NE on IMA Link
183.1 Failure Event Report
183.2 Error DescriptionImplementation specific TX fault declared at the near end (NE). This alarm indication that a hardware specific defect has been detected in the Tx direction on one link of the IMAGroup. If this alarm occurs then the ImaGroup will automatically cease transmitting on the link and (assuming that there are sufficient good links for the Group to remain Operational) continue to operate using the remaining good links. This alarm is likely to be due to faulty hardware at the near end.
183.3 Troubleshooting (LMT)Contact the technical assistance center (TAC) to get support in isolating the fault. For suitable preparation save the error symptoms as described in “Collect Info for Assis-tance”. Log files need to be analyzed and specific measures must be taken which are out of the operator’s scope.
Managed Object Class / Hardware Type:
ImaLink
Event Type: communicationsAlarm
Probable Cause: VendorSpecific
Severity: minor
DN70580522 Issue 01A
261
Troubleshooting Node B 202084 - Rx fault declared at the NE on IMA Link
Id:0900d8058022b878Confidential
184 202084 - Rx fault declared at the NE on IMA Link
184.1 Failure Event Report
184.2 Error DescriptionImplementation specific RX fault declared at the near end (NE). This alarm indication that a hardware specific defect has been detected in the Rx direction on one link of the IMAGroup. If this alarm occurs then the ImaGroup will automatically cease transmitting on the link and (assuming that there are sufficient good links for the Group to remain operation) continue to operate using the remaining good links. This alarm is likely to be due to faulty hardware at either end.
184.3 Troubleshooting (LMT)Contact the technical assistance center (TAC) to get support in isolating the fault. For suitable preparation save the error symptoms as described in “Collect Info for Assis-tance”. Log files need to be analyzed and specific measures must be taken which are out of the operator’s scope.
Managed Object Class / Hardware Type:
ImaLink
Event Type: communicationsAlarm
Probable Cause: VendorSpecific
Severity: minor
262 DN70580522Issue 01A
Troubleshooting Node B
Id:0900d8058022b880Confidential
202085 - FE has reported Tx-Unusable on IMA Link
185 202085 - FE has reported Tx-Unusable on IMA Link
185.1 Failure Event Report
185.2 Error DescriptionThe far end (FE) has reported that the link is unusable in the TX direction. When the ImaGroup is starting up this is an indication that would be expected before the link gets to its normal operating state and so does not necessarily indicate a problem. Thereafter this alarm indication means that the link is no longer active for some reason that may be indicated by other alarms. If this alarm occurs then the ImaGroup will automatically cease transmitting on the link and (assuming that there are sufficient good links for the Group to remain Operational) continue to operate using the remaining good links.
185.3 Troubleshooting (LMT)Take the following measures to clear the alarm cause:1. Check the cable connections.2. If the cable connections were not indicated as basic cause, contact the technical
assistance center (TAC) to get support in isolating the fault. For suitable preparation save the error symptoms as described in “Collect Info for Assistance”. Log files need to be analyzed and specific measures must be taken which are out of the operator’s scope.
Managed Object Class / Hardware Type:
ImaLink
Event Type: communicationsAlarm
Probable Cause: VendorSpecific
Severity: minor
DN70580522 Issue 01A
263
Troubleshooting Node B 202086 - FE has reported Rx-Unusable on IMA Link
Id:0900d8058022b888Confidential
186 202086 - FE has reported Rx-Unusable on IMA Link
186.1 Failure Event Report
186.2 Error DescriptionThe far end (FE) has reported that the link is unusable in the RX direction. When the ImaGroup is starting up this is an indication that would be expected before the link gets to its normal operating state and so does not necessarily indicate a problem. Thereafter this alarm indication means that the link is no longer active for some reason that may be indicated by other alarms. If this alarm occurs then the ImaGroup will automatically cease transmitting on the link and (assuming that there are sufficient good links for the Group to remain Operational) continue to operate using the remaining good links.
186.3 Troubleshooting (LMT)Take the following measures to clear the alarm cause:1. Check the cable connections.2. If the cable connections were not indicated as basic cause, contact the technical
assistance center (TAC) to get support in isolating the fault. For suitable preparation save the error symptoms as described in “Collect Info for Assistance”. Log files need to be analyzed and specific measures must be taken which are out of the operator’s scope.
Managed Object Class / Hardware Type:
ImaLink
Event Type: communicationsAlarm
Probable Cause: VendorSpecific
Severity: minor
264 DN70580522Issue 01A
Troubleshooting Node B
Id:0900d8058022b88eConfidential
202087 - Startup FE reported on IMA Group
187 202087 - Startup FE reported on IMA Group
187.1 Failure Event Report
187.2 Error DescriptionThe far end (FE) IMA Group is in the Startup state. This alarm indication should be seen as part of the normal startup procedure of the Group and does not necessarily indicate a problem. Thereafter it indicates that the Group has reset to its startup state for some reason that may be explained by other alarms.
187.3 Troubleshooting (LMT)Contact the technical assistance center (TAC) to get support in isolating the fault. For suitable preparation save the error symptoms as described in “Collect Info for Assis-tance”. Log files need to be analyzed and specific measures must be taken which are out of the operator’s scope.
Managed Object Class / Hardware Type:
ImaGroup
Event Type: communicationsAlarm
Probable Cause: VendorSpecific
Severity: major
DN70580522 Issue 01A
265
Troubleshooting Node B 202088 - Config Abort reported on IMA Group
Id:0900d8058022b896Confidential
188 202088 - Config Abort reported on IMA Group
188.1 Failure Event Report
188.2 Error Descriptiong NOTE
If an IMA group has been configured, however, not being operational during start-up, the Node B possibly restarts some minutes after start-up.
This indication means that the IMA Group has aborted its attempted startup for some reason. This may be because the IMA Group at the far end has been configured with incompatible attributes to those that have been used at the near end. Possible incom-patible attributes are: Frame Length, Group Symmetry or the IMA Version. These may be fixable by modification to the configuration at one or both ends.
188.3 Troubleshooting (LMT)Check the hardware compatibility of the configuration.
Managed Object Class / Hardware Type:
ImaGroup
Event Type: communicationsAlarm
Probable Cause: VendorSpecific
Severity: major
266 DN70580522Issue 01A
Troubleshooting Node B
Id:0900d8058022b89eConfidential
202089 - Config Abort FE reported on IMA Group
189 202089 - Config Abort FE reported on IMA Group
189.1 Failure Event Report
189.2 Error Descriptiong NOTE
If an IMA group has been configured, however, not being operational during start-up, the Node B possibly restarts some minutes after start-up.
This indication is the same as the imaGroupConfigAbort (see: 202088 - Config Abort reported on IMA Group) but has been reported by the far end (FE) IMA to the near end (NE). The causes and possible fixes are the same as for the imaGroupConfigAbort.
189.3 Troubleshooting (LMT)Check the hardware compatibility of the configuration.
Managed Object Class / Hardware Type:
ImaGroup
Event Type: communicationsAlarm
Probable Cause: VendorSpecific
Severity: major
DN70580522 Issue 01A
267
Troubleshooting Node B 202090 - Insufficient Links reported at NE on IMAGroup
Id:0900d8058022b8a6Confidential
190 202090 - Insufficient Links reported at NE on IMA Group
190.1 Failure Event Report
190.2 Error Descriptiong NOTE
If an IMA group has been configured, however, not being operational during start-up, the Node B possibly restarts some minutes after start-up.
The near end (NE) has reported that the number of active links (operational state = enabled) is less than is required for the group to be operational.
This may be caused by one of the following: • The configuration of the group requires more links than have been configured. • One or more links are non-operational for other reasons, such as fault conditions. • One or more links have not yet completed their startup procedure.
If enough links have been configured, the status of these links must be examined to determine why not sufficiently enough of these links are in the operational state enabled.
At startup of the group this alarm indication would normally be expected to be seen as the group performs its startup procedure.
190.3 Troubleshooting (LMT)Perform the following tasks to solve this error:1. Check Node B database.
Use the mibCheck or mibCheckWin tool which is supplied with the Node B software. Refer to the “Node B Database Editing Guide”.The number of links required for the group to be operational is configured by the attri-bute “imaGroupMinNumLinks”
2. Change Node B database.Proceed according to the “Node B Database Editing Guide”.
Managed Object Class / Hardware Type:
ImaGroup
Event Type: communicationsAlarm
Probable Cause: VendorSpecific
Severity: major
268 DN70580522Issue 01A
Troubleshooting Node B
Id:0900d8058022b8aeConfidential
202091 - Insufficient Links at FE reported on IMA Group
191 202091 - Insufficient Links at FE reported on IMA Group
191.1 Failure Event Report
191.2 Error Descriptiong NOTE
If an IMA group has been configured, however, not being operational during start-up, the Node B possibly restarts some minutes after start-up.
The far end (FE) has reported that the number of active links (operational state = enabled) is less than is required for the group to be operational.
The reasons and actions for this alarm are similar to those described for the Insufficient Links indication at the near end (see: 202090 - Insufficient Links reported at NE on IMA Group).
191.3 Troubleshooting (LMT)Perform the following tasks to solve this error:1. Check Node B database.
Use the mibCheck or mibCheckWin tool which is supplied with the Node B software. Refer to the “Node B Database Editing Guide”.The number of links required for the group to be operational is configured by the attri-bute “imaGroupMinNumLinks”
2. Change Node B database.Proceed according to the “Node B Database Editing Guide”.
Managed Object Class / Hardware Type:
ImaGroup
Event Type: communicationsAlarm
Probable Cause: VendorSpecific
Severity: major
DN70580522 Issue 01A
269
Troubleshooting Node B 202092 - Group Blocked at FE reported on IMA Group
Id:0900d8058022b8b6Confidential
192 202092 - Group Blocked at FE reported on IMA Group
192.1 Failure Event Report
192.2 Error DescriptionThe far end (FE) IMA group has been blocked (i.e. its adminstrative state has been set to locked by the operator at the far end). As a consequence, the far end IMA group is not operating.
192.3 Troubleshooting (LMT)Perform the following tasks to solve this error:1. Check the administrative state of the IMA group at the far end (FE).2. Change the administrative state to unlocked at the far end.
Managed Object Class / Hardware Type:
ImaGroup
Event Type: communicationsAlarm
Probable Cause: VendorSpecific
Severity: major
270 DN70580522Issue 01A
Troubleshooting Node B
Id:0900d8058022b8beConfidential
202093 - Timing Synch error reported on IMA Group
193 202093 - Timing Synch error reported on IMA Group
193.1 Failure Event Report
193.2 Error Descriptiong NOTE
If an IMA group has been configured, however, not being operational during start-up, the Node B possibly restarts some minutes after start-up.
The far end (FE) transmit clock mode is different from the near end (NE) transmit clock mode due to different configuration of the group. The imaGroupNeTxClkMode at both ends should be set to CTC (Common Transmit Clock).
193.3 Troubleshooting (LMT)Perform the following tasks to solve this error:1. Check Node B database.
Use the mibCheck or mibCheckWin tool which is supplied with the Node B software. Refer to the “Node B Database Editing Guide”.The number of links required for the group to be operational is configured by the attri-bute “imaGroupMinNumLinks”
2. Change Node B database.Proceed according to the “Node B Database Editing Guide”.
Managed Object Class / Hardware Type:
ImaGroup
Event Type: communicationsAlarm
Probable Cause: VendorSpecific
Severity: major
DN70580522 Issue 01A
271
Troubleshooting Node B 202095 - The Near End IMA has detected an invalidversion set by the Far End
Id:0900d8058022b8c6Confidential
194 202095 - The Near End IMA has detected an invalid version set by the Far End
194.1 Failure Event Report
194.2 Error DescriptionThe Node B does only support IMA version 1.1. The far end IMA group, however, is using a different IMA version. This indicates that the far end hardware configuration is incompatible with the near end hardware.
194.3 Troubleshooting (LMT)Check the hardware compatibility of the configuration in the far end.
Managed Object Class / Hardware Type:
ImaGroup
Event Type: communicationsAlarm
Probable Cause: VendorSpecific
Severity: major
272 DN70580522Issue 01A
Troubleshooting Node B
Id:0900d8058022b8ceConfidential
202097 - Loss of Continuity detected on an ATM VP
195 202097 - Loss of Continuity detected on an ATM VP
195.1 Failure Event Report
195.2 Error DescriptionThe VpCTP or the VpTTP which contains the continuity monitor does not receive the expected continuity check cells from the source.
195.3 Troubleshooting (LMT)Troubleshooting has to start with investigation on other alarms. Therefore, check whether alarms at upstream NEs are present in the ALARM View window of the LMT:1. Click on the “Alarm View” button or use the shortkey Ctrl + A .2. Proceed according to the troubleshooting of the trigger alarm.
If either no such alarm is present or if the actions taken above did not clear the condition for this alarm, perform the following steps in the given order to cease this alarm:1. Confirm that all relevant cables are connected properly.2. If these actions did not help to solve this error, contact the technical assistance
center (TAC) to get support in isolating the fault. For suitable preparation save the error symptoms as described in “Collect Info for Assistance”. Log files need to be analyzed and specific measures must be taken which are out of the operator’s scope.
Managed Object Class / Hardware Type:
ContinuityMonitor
Event Type: communicationsAlarm
Probable Cause: VendorSpecific
Severity: minor
DN70580522 Issue 01A
273
Troubleshooting Node B 202098 - CRC4 not used by FE reported on E1TTP
Id:0900d8058022b8d4Confidential
196 202098 - CRC4 not used by FE reported on E1TTP
196.1 Failure Event Report
196.2 Error DescriptionA loss of multiframe alignment occurred and the following indication has been received on the reporting E1 physical link: ’CRC4 not used by far end (FE)’.
The ’202098 - CRC4 not used by FE reported on E1TTP’ alarm indicates that no multi-frame synchronization could be found. This may be due to the follwing: • Misconfiguration of the hardware at either end • Faulty hardware at either end • Problems on the transmission medium between the two ends
The "202098 - CRC4 not used by FE Indication on E1 Physical Link" alarm may be caused by the following:
The Node B's E1TTP managed object's attribute crcOperationMode, which indicates the mode of CRC operation, is set to crcAutomatic whereas the frame format for the RNC is set to 0 meaning that the CRC is disabled.
The "202098 - CRC4 not used by FE Indication on E1 Physical Link" does not cause any change of the reporting E1TTP's OST/AVS.
196.3 Troubleshooting (LMT)Contact the technical assistance center (TAC) to get support in isolating the fault. For suitable preparation save the error symptoms as described in “Collect Info for Assis-tance”. Log files need to be analyzed and specific measures must be taken which are out of the operator’s scope.
Managed Object Class / Hardware Type:
E1TTP
Event Type: communicationsAlarm
Probable Cause: VendorSpecific
Severity: warning
274 DN70580522Issue 01A
Troubleshooting Node B
Id:0900d8058022b8daConfidential
202106 - Software activation failed
197 202106 - Software activation failed
197.1 Failure Event Report
197.2 Error DescriptionThe activation of a software load failed in the previous run.
As a consequence, the Node B now automatically switched back to the previously running software load.
197.3 Troubleshooting (LMT)Contact the technical assistance center (TAC) to get support in isolating the fault. For suitable preparation save the error symptoms as described in “Collect Info for Assis-tance”. Log files need to be analyzed and specific measures must be taken which are out of the operator’s scope.
Managed Object Class / Hardware Type:
Osu
Event Type: processingErrorAlarm
Probable Cause: SoftwareError
Severity: warning
DN70580522 Issue 01A
275
Troubleshooting Node B 202107 - Database activation failed
Id:0900d8058022b8e0Confidential
198 202107 - Database activation failed
198.1 Failure Event Report
198.2 Error DescriptionThe activation of a database failed in the previous run.
As a consequence, the Node B now automatically switched back to the previously running database.
198.3 Troubleshooting (LMT)Contact the technical assistance center (TAC) to get support in isolating the fault. For suitable preparation save the error symptoms as described in “Collect Info for Assis-tance”. Log files need to be analyzed and specific measures must be taken which are out of the operator’s scope.
Managed Object Class / Hardware Type:
Osu
Event Type: processingErrorAlarm
Probable Cause: ConfigurationOrCustomizationError
Severity: warning
276 DN70580522Issue 01A
Troubleshooting Node B
Id:0900d8058022b8e6Confidential
202108 - Reliable software started without prior explicit activation
199 202108 - Reliable software started without prior explicit activation
199.1 Failure Event Report
199.2 Error DescriptionThe reliable software was started without a prior explicit activation procedure (automatic fallback).
This case occurs due to one of the following situations: • No activation is running and the start-up with the running software failed three times
in a row. • An error occurred in a very early boot phase.
199.3 Troubleshooting (LMT)Contact the technical assistance center (TAC) to get support in isolating the fault. For suitable preparation save the error symptoms as described in “Collect Info for Assis-tance”. Log files need to be analyzed and specific measures must be taken which are out of the operator’s scope.
Managed Object Class / Hardware Type:
Osu
Event Type: processingErrorAlarm
Probable Cause: SoftwareError
Severity: warning
DN70580522 Issue 01A
277
Troubleshooting Node B 202109 - Reliable database started without prior explic-it activation
Id:0900d8058022b8ecConfidential
200 202109 - Reliable database started without prior explicit activation
200.1 Failure Event Report
200.2 Error DescriptionThe reliable database was started without a prior explicit activation procedure (auto-matic fallback).
This case occurs due to one of the following situations: • No activation is running and the start-up with the reliable database failed three times
in a row. • An error occurred in a very early boot phase.
200.3 Troubleshooting (LMT)Contact the technical assistance center (TAC) to get support in isolating the fault. For suitable preparation save the error symptoms as described in “Collect Info for Assis-tance”. Log files need to be analyzed and specific measures must be taken which are out of the operator’s scope.
Managed Object Class / Hardware Type:
Osu
Event Type: processingErrorAlarm
Probable Cause: SoftwareError
Severity: warning
278 DN70580522Issue 01A
Troubleshooting Node B
Id:0900d8058022b8f2Confidential
202358 - CAN received an unexpected message
201 202358 - CAN received an unexpected message
201.1 Failure Event Report
201.2 Error DescriptionThe Node B CAN communicates with various devices via CAN bus. The Core Controller software verifies the communication scenarios. This fault report will be generated, if the Core Controller software detects an unexpected message in the actual message sce-nario. The affected Node B may continue to operate in a degraded mode.
The probable cause for that condition could either be a hardware failure or a software failure.
201.3 Troubleshooting (LMT)1. Any CAN bus participant may cause the problem. Check all CAN bus participants in
order to isolate the fault.2. First, reset the addressed card. Use the TREE View window of the LMT or, alterna-
tively, apply the Cc “reset” command to the addressed card.3. If the fault cannot be cleared by reset, the addressed card has to be replaced.
Replacement must be done according to the “Replacing Node B Units” instructions.4. If the card replacement did not clear the fault, contact the technical assistance
center (TAC) to get support in isolating the fault. For suitable preparation save the error symptoms as described in “Collect Info for Assistance”. Log files need to be analyzed and specific measures must be taken which are out of the operator’s scope.
Managed Object Class / Hardware Type:
Cc
Event Type: communicationsAlarm
Probable Cause: InvalidMessageReceived
Severity: warning
DN70580522 Issue 01A
279
Troubleshooting Node B 202360 - A necessary resource is missed
Id:0900d8058022b8f8Confidential
202 202360 - A necessary resource is missed
202.1 Failure Event Report
202.2 Error DescriptionThe Node B communicates with various devices via a CAN bus. This fault report will be generated, if the Core Controller cannot initialize its local resources. This condition leads to a recovery reset. The affected Node B is therefore temporarily not operational.
The probable cause for that condition could either be a hardware failure or a software failure.
202.3 Troubleshooting (LMT)1. Any CAN bus participant may cause the problem. Check all CAN bus participants in
order to isolate the fault.2. First, reset the addressed card.
Use the TREE View window of the LMT or, alternatively, apply the Cc “reset” command to the addressed card.
3. If the fault cannot be cleared by reset, the addressed card has to be replaced.Replacement must be done according to the “Replacing Node B Units” instructions.
4. If the card replacement did not clear the fault, contact the technical assistance center (TAC) to get support in isolating the fault. For suitable preparation save the error symptoms as described in “Collect Info for Assistance”. Log files need to be analyzed and specific measures must be taken which are out of the operator’s scope.
Managed Object Class / Hardware Type:
Cc
Event Type: processingErrorAlarm
Probable Cause: UnderlyingRessourceUnavailable
Severity: critical
280 DN70580522Issue 01A
Troubleshooting Node B
Id:0900d8058022b8feConfidential
202406 - ALCAP protocol error
203 202406 - ALCAP protocol error
203.1 Failure Event Report
203.2 Error DescriptionALCAP (access link control application part) protocol errors are an indication of one of the following conditions:
• Messages are being corrupted over the Iub interface. • Software implementation problems between RNC and Node B. • ALCAP protocol in the RNC has been upgraded to a later version of the specifica-
tion (ITU-T Q.2630.1).
203.3 Troubleshooting (LMT)Contact the technical assistance center (TAC) to get support in isolating the fault. For suitable preparation save the error symptoms as described in “Collect Info for Assis-tance”. Log files need to be analyzed and specific measures must be taken which are out of the operator’s scope.
Managed Object Class / Hardware Type:
Cc
Event Type: communicationsAlarm
Probable Cause: CommunicationProtocolError
Severity: warning
DN70580522 Issue 01A
281
Troubleshooting Node B 202431 - ALCAP transaction to RNC initiated by trans-port timed out
Id:0900d8058022b904Confidential
204 202431 - ALCAP transaction to RNC initiated by transport timed out
204.1 Failure Event Report
204.2 Error DescriptionAn ITR (transport management subsystem) initiated Iub request on ALCAP (access link control application part) has timed out. This means that block request, unblock request or reset request has been requested by ITR and has timed out before a reply has been received from the RNC.
This condition is fairly serious as it can lead to a configuration misalignment between RNC and Node B. This error could either be caused by congestion or a failure in the ALCAP socket between RNC and Node B.
204.3 Troubleshooting (LMT)Contact the technical assistance center (TAC) to get support in isolating the fault. For suitable preparation save the error symptoms as described in “Collect Info for Assis-tance”. Log files need to be analyzed and specific measures must be taken which are out of the operator’s scope.
Managed Object Class / Hardware Type:
Cc
Event Type: qualityOfServiceAlarm
Probable Cause: Congestion
Severity: warning
282 DN70580522Issue 01A
Troubleshooting Node B
Id:0900d8058022b90aConfidential
202432 - ALCAP transaction to RNC initiated by NBAP timed out
205 202432 - ALCAP transaction to RNC initiated by NBAP timed out
205.1 Failure Event Report
205.2 Error DescriptionA CPN (call processing NBAP) initiated Iub request on ALCAP (access link control application part) has timed out. This means that reset request or release request has been requested by CPN and has timed out before a reply has been received from the RNC.
This condition is fairly serious as it can lead to a configuration misalignment between RNC and Node B. This error could either be caused by congestion or a failure in the ALCAP socket between RNC and Node B.
205.3 Troubleshooting (LMT)Contact the technical assistance center (TAC) to get support in isolating the fault. For suitable preparation save the error symptoms as described in “Collect Info for Assis-tance”. Log files need to be analyzed and specific measures must be taken which are out of the operator’s scope.
Managed Object Class / Hardware Type:
Cc
Event Type: qualityOfServiceAlarm
Probable Cause: Congestion
Severity: warning
DN70580522 Issue 01A
283
Troubleshooting Node B 202433 - Configuration misalignment between RNCand CPA
Id:0900d8058022b910Confidential
206 202433 - Configuration misalignment between RNC and CPA
206.1 Failure Event Report
206.2 Error DescriptionThis error occurs when RNC sends a message to CPA (call processing ALCAP) to perform an action which is not valid. Such actions include:
• RNC attempts to block a path which is already blocked or does not exist. • RNC attempts to unblock a path which is already unblocked or does not exist. • RNC attempts to reset a path which does not exist. • RNC attempts to release a non-existent connection.
While not a serious problem in itself, these unexpected actions could point to either a software error or a configuration misalignment between RNC and CPA which is serious.
206.3 Troubleshooting (LMT)Contact the technical assistance center (TAC) to get support in isolating the fault. For suitable preparation save the error symptoms as described in “Collect Info for Assis-tance”. Log files need to be analyzed and specific measures must be taken which are out of the operator’s scope.
Managed Object Class / Hardware Type:
Cc
Event Type: communicationsAlarm
Probable Cause: SscopFailure
Severity: warning
284 DN70580522Issue 01A
Troubleshooting Node B
Id:0900d8058022b916Confidential
202434 - RNC Establish Request message received which is invalid or cannot be handled
207 202434 - RNC Establish Request message received which is invalid or cannot be handled
207.1 Failure Event Report
207.2 Error DescriptionThis error indicates that an ALCAP (access link control application part) establish request message has been received from the RNC which is either invalid or cannot be handled.
Possible errors include:
• Establish request for a connection which is destined to be routed to a BB (baseband) card that is not in service (this is an NBAP/BB card problem).
• Establish request which contains an invalid binding ID. • Establish request with an invalid NSEA (NSAP service endpoint address) address
for the Node B. • Establish request which contains unexpected parameters for this implementation. • Establish request for a path which does not exist • Establish request for a channel that is already in use. • Establish request with no TCI (test connection indication) for a path which is locally
blocked.
These either indicate a problem with the RNC or internal subsystems.
207.3 Troubleshooting (LMT)Contact the technical assistance center (TAC) to get support in isolating the fault. For suitable preparation save the error symptoms as described in “Collect Info for Assis-tance”. Log files need to be analyzed and specific measures must be taken which are out of the operator’s scope.
Managed Object Class / Hardware Type:
Cc
Event Type: communicationsAlarm
Probable Cause: CommunicationProtocolError
Severity: warning
DN70580522 Issue 01A
285
Troubleshooting Node B 202435 - CPA to RNC communication (socket) prob-lems
Id:0900d8058022b91cConfidential
208 202435 - CPA to RNC communication (socket) problems
208.1 Failure Event Report
208.2 Error DescriptionThis error occurs if data that is about to be sent is lost due to the TNP (transport network protocol) socket between Node B and RNC either being out-of-service or returning error.
This is a serious problem as, if there is no retry mechanism (e.g. for release requests), then configuration misalignment could result between RNC and Node B.
The following subsequent alarm may also be initiated: 200656 - Iub link broke down
208.3 Troubleshooting (LMT)Contact the technical assistance center (TAC) to get support in isolating the fault. For suitable preparation save the error symptoms as described in “Collect Info for Assis-tance”. Log files need to be analyzed and specific measures must be taken which are out of the operator’s scope.
Managed Object Class / Hardware Type:
Cc
Event Type: communicationsAlarm
Probable Cause: SscopFailure
Severity: critical
286 DN70580522Issue 01A
Troubleshooting Node B
Id:0900d805806e5132Confidential
202506 - Node B system clock in holdover mode
209 202506 - Node B system clock in holdover mode
209.1 Failure Event Report
209.2 Error DescriptionThe reference input for the Node B system clock is not available or not stable enough for synchronization. System clock oscillator is running without external synchronization (holdover mode). This may be due to incorrect configuration of the clock management in the Node B database, or due to insufficient signal quality of the reference clock source.
The faults leading to the following alarms make the Node B’s system clock switch to holdover mode: • 202056 – Loss Of Signal on Physical Link • 202057 – Loss Of Frame on Physical Link • 202059 – Alarm Indication Signal on Physical Link • 202062 – Line Alarm Indication Signal Indication on STM1 Physical Link
g In the event of microwave links, the clock quality can be degraded due to either propagation problems or protection switching. As consequence, some other Node Bs in the same connected area may be affected, as well.
209.3 Troubleshooting (LMT)All clock signals in the Node B are derived from an internal high accuracy master clock (OC-VCXO) which is synchronized to a reference clock signal by PLL. This reference clock can be derived from the Iub interface (E1/J1/T1 or STM-1/OC-3) or from an external source connected to the external synchronization input.
With the ClMng managed object in the nbDatabase not only the source for the reference clock can be defined but also the priority order of up to four (4) possible sources can be selected. If the reference clock is lost or is not of sufficient quality the internal clock (OC-VCXO) will still work within 3GPP frequency stability limit of 0.05 ppm for at least two (2) days. The working state is holdover mode – high accuracy, see clockAccuracyStatus parameter.
1. Reference clock lostIf the reference clock is derived from an E1/J1/T1 or STM-1/OC-3 line and the relevant incoming Iub signal is lost or degraded concentrate on fixing the Iub inter-face alarm first as they are:– 202056 - Loss Of Signal on Physical Link
Managed Object Class / Hardware Type:
ClMng
Event Type: equipmentAlarm
Probable Cause: TimingProblem
Severity: minor
DN70580522 Issue 01A
287
Troubleshooting Node B 202506 - Node B system clock in holdover mode
Id:0900d805806e5132Confidential
– 202057 - Loss Of Frame on Physical Link– 202070 - Signal Degrade Indication on STM1 Physical Link– 202071 - Excessive Bit Error Rate Indication on STM1 Physical Link
2. Clock management configuration incorrectThe ClMng managed object in the nbDatabase defines the reference clock sources and their priority. The prioClockSourceList parameter of the ClMng managed object contains one to four clock sources. In this priority list, the priority is assigned to the clock sources by the order of the elements in the list. Thus, the first entry has the highest priority.The list has to contain a minimum of one entry and a maximum of four entries. Fur-thermore clock sources must not be duplicated in the list and have to exist.Each entry consists of both a reference to a physical line MO (E1TTP, J1TTP, Stm1TP) via the MO’s FDN and the actual line type of the reference line.Thus, take the following measures:– Upload the nbDatabase
Use the TREE View window of the LMT and apply the Osu “uploadDataInitiate” command to the relevant Osu managed object.
– Check for right configuration of ports and line types within the ClMng managed object as well as the stm1Port and lineCircuitAddress parameters of the trans-port-related MOCs, Stm1TP and E1TTP/J1TTP, respectively. For details, consult the OGL:Node B DB Description.
3. Reference signal quality insufficientFor further investigation, contact the technical assistance center (TAC) to get support in isolating the fault. For suitable preparation save the error symptoms as described in “Collect Info for Assistance”. Log files need to be analyzed and specific measures must be taken which are out of the operator’s scope.
288 DN70580522Issue 01A
Troubleshooting Node B
Id:0900d805806e6c6cConfidential
202507 - Node B system clock in medium accuracy
210 202507 - Node B system clock in medium accuracy
210.1 Failure Event Report
210.2 Error DescriptionThe accuracy of the Node B system clock is in medium accuracy range. This may be due to insufficient signal quality of the reference clock source.
The following preceded alarm should have been reported: 202506 - Node B system clock in holdover mode
210.3 Troubleshooting (LMT)All clock signals in the Node B are derived from an internal high accuracy master clock (OC-VCXO) which is synchronized to a reference clock signal by PLL. This reference clock can be derived from the Iub interface (E1/J1/T1 or STM-1/OC-3) or from an external source connected to the external synchronization input.
With the ClMng managed object in the nbDatabase not only the source for the reference clock can be defined but also the priority order of up to four (4) possible sources can be selected. If the reference clock is lost or is not of sufficient quality the internal clock (OC-VCXO) will first change to the working state holdover mode – high accuracy, see clockAccuracyStatus parameter. But if the bad synchronization remains for up to two (2) days, the Node B will go from holdover mode – high accuracy to holdover mode – medium accuracy. In this case, the frequency stability can only be guaranteed for a few days and after this period there is a possibility that the Node B will transmit outside 0.05 ppm.
1. Reference clock lostIf the reference clock is derived from an E1/J1/T1 or STM-1/OC-3 line and the relevant incoming Iub signal is lost or degraded concentrate on fixing the Iub inter-face alarm first as they are:– 202056 - Loss Of Signal on Physical Link– 202057 - Loss Of Frame on Physical Link– 202070 - Signal Degrade Indication on STM1 Physical Link– 202071 - Excessive Bit Error Rate Indication on STM1 Physical Link
2. Clock management configuration incorrectThe ClMng managed object in the nbDatabase defines the reference clock sources and their priority. The prioClockSourceList parameter of the ClMng managed object contains one to four clock sources. In this priority list, the priority is assigned to the
Managed Object Class / Hardware Type:
ClMng
Event Type: equipmentAlarm
Probable Cause: TimingProblem
Severity: minor
DN70580522 Issue 01A
289
Troubleshooting Node B 202507 - Node B system clock in medium accuracy
Id:0900d805806e6c6cConfidential
clock sources by the order of the elements in the list. Thus, the first entry has the highest priority.The list has to contain a minimum of one entry and a maximum of four entries. Fur-thermore clock sources must not be duplicated in the list and have to exist.Each entry consists of both a reference to a physical line MO (E1TTP, J1TTP, Stm1TP) via the MO’s FDN and the actual line type of the reference line.Thus, take the following measures:– Upload the nbDatabase
Use the TREE View window of the LMT and apply the Osu “uploadDataInitiate” command to the relevant Osu managed object.
– Check for right configuration of ports and line types within the ClMng managed object as well as the stm1Port and lineCircuitAddress parameters of the trans-port-related MOCs, Stm1TP and E1TTP/J1TTP, respectively. For details, consult the OGL:Node B DB Description.
3. Reference signal quality insufficientFor further investigation, contact the technical assistance center (TAC) to get support in isolating the fault. For suitable preparation save the error symptoms as described in “Collect Info for Assistance”. Log files need to be analyzed and specific measures must be taken which are out of the operator’s scope.
290 DN70580522Issue 01A
Troubleshooting Node B
Id:0900d8058022b92eConfidential
262041 - System call unsuccessful
211 262041 - System call unsuccessful
211.1 Failure Event Report
211.2 Error DescriptionA system call was not successful. As a consequence, the CC (Core Controller) will be reset, because the software is not capable of working stable any longer. The problem has to be analyzed by the customer service.
211.3 Troubleshooting (LMT)Contact the technical assistance center (TAC) to get support in isolating the fault. For suitable preparation save the error symptoms as described in “Collect Info for Assis-tance”. Log files need to be analyzed and specific measures must be taken which are out of the operator’s scope.
Managed Object Class / Hardware Type:
*
Event Type: processingErrorAlarm
Probable Cause: SystemCallUnsuccessful
Severity: critical
DN70580522 Issue 01A
291
Troubleshooting Node B 262042 - Unexpected software error
Id:0900d8058022b934Confidential
212 262042 - Unexpected software error
212.1 Failure Event Report
212.2 Error DescriptionAn unexpected software error occurred. As a consequence, the CC (Core Controller) will be reset, because the software is not capable of working stable any longer. The problem has to be analyzed by the customer service.
212.3 Troubleshooting (LMT)Contact the technical assistance center (TAC) to get support in isolating the fault. For suitable preparation save the error symptoms as described in “Collect Info for Assis-tance”. Log files need to be analyzed and specific measures must be taken which are out of the operator’s scope.
Managed Object Class / Hardware Type:
*
Event Type: processingErrorAlarm
Probable Cause: SoftwareError
Severity: critical
292 DN70580522Issue 01A
Troubleshooting Node B
Id:0900d8058022b93aConfidential
262043 - Error from device driver received
213 262043 - Error from device driver received
213.1 Failure Event Report
213.2 Error DescriptionA function call to a device driver returned an error. In most of the cases the CC (Core Controller) will be reset as a consequence. The problem has to be analyzed by the customer service.
213.3 Troubleshooting (LMT)Contact the technical assistance center (TAC) to get support in isolating the fault. For suitable preparation save the error symptoms as described in “Collect Info for Assis-tance”. Log files need to be analyzed and specific measures must be taken which are out of the operator’s scope.
Managed Object Class / Hardware Type:
*
Event Type: processingErrorAlarm
Probable Cause: SoftwareError
Severity: critical
DN70580522 Issue 01A
293
Troubleshooting Node B 262044 - Not enough memory to initialize software
Id:0900d8058022b941Confidential
214 262044 - Not enough memory to initialize software
214.1 Failure Event Report
214.2 Error DescriptionAt start-up time the OS (operating system) could not allocate enough memory for task stacks, message buffers and dynamic memory management etc.. The problem has to be analyzed by the customer service.
214.3 Troubleshooting (LMT)Contact the technical assistance center (TAC) to get support in isolating the fault. For suitable preparation save the error symptoms as described in “Collect Info for Assis-tance”. Log files need to be analyzed and specific measures must be taken which are out of the operator’s scope.
Managed Object Class / Hardware Type:
Cc
Event Type: processingErrorAlarm
Probable Cause: OutOfMemory
Severity: critical
294 DN70580522Issue 01A
Troubleshooting Node B
Id:0900d8058022b947Confidential
262045 - Memory allocation failure
215 262045 - Memory allocation failure
215.1 Failure Event Report
215.2 Error DescriptionThe system did not have enough free memory to satisfy a memory allocation request. As a consequence, the CC (Core Controller) will be reset. The problem has to be analyzed by the customer service.
215.3 Troubleshooting (LMT)Contact the technical assistance center (TAC) to get support in isolating the fault. For suitable preparation save the error symptoms as described in “Collect Info for Assis-tance”. Log files need to be analyzed and specific measures must be taken which are out of the operator’s scope.
Managed Object Class / Hardware Type:
*
Event Type: processingErrorAlarm
Probable Cause: OutOfMemory
Severity: critical
DN70580522 Issue 01A
295
Troubleshooting Node B 262046 - Unexpected exception handling
Id:0900d8058022b94dConfidential
216 262046 - Unexpected exception handling
216.1 Failure Event Report
216.2 Error DescriptionAn unexpected exception was thrown. As a consequence, the CC (Core Controller) will be reset, because the software is not capable of working stable any longer. The problem has to be analyzed by the customer service.
216.3 Troubleshooting (LMT)Contact the technical assistance center (TAC) to get support in isolating the fault. For suitable preparation save the error symptoms as described in “Collect Info for Assis-tance”. Log files need to be analyzed and specific measures must be taken which are out of the operator’s scope.
Managed Object Class / Hardware Type:
*
Event Type: processingErrorAlarm
Probable Cause: SoftwareError
Severity: critical
296 DN70580522Issue 01A
Troubleshooting Node B
Id:0900d8058022b953Confidential
262047 - Uncaught exception handling
217 262047 - Uncaught exception handling
217.1 Failure Event Report
217.2 Error DescriptionA thrown exception was not caught. As a consequence, the CC (Core Controller) will be reset, because the software is not capable of working stable any longer. The problem has to be analyzed by the customer service.
217.3 Troubleshooting (LMT)Contact the technical assistance center (TAC) to get support in isolating the fault. For suitable preparation save the error symptoms as described in “Collect Info for Assis-tance”. Log files need to be analyzed and specific measures must be taken which are out of the operator’s scope.
Managed Object Class / Hardware Type:
*
Event Type: processingErrorAlarm
Probable Cause: SoftwareError
Severity: critical
DN70580522 Issue 01A
297
Troubleshooting Node B Appendix
Id:0900d8058022b0c6Confidential
218 AppendixThis appendix contains information about the following topics: • Fault management in the NB/RSxxx • Mapping of NB/RSxxx alarms to NetAct alarms
218.1 Fault management in the NB/RSxxxThe fault management (FM) function implemented in the NB/RSxxx manages abnormal behavior of the NB/RSxxx, caused by faults. Faults are events which cause the NB/RSxxx to perform in a way that is different from the normal one. They are detected through errors in the operation of the NB/RSxxx and are then reported to users in various ways (LED status on cards and modules, alarms, etc.).
Failures and faults occurring in the NB/RSxxx may cause deterioration of the NB/RSxxx’s function and/or quality of service (QoS). In severe cases, this decay can lead to situations in which the NB/RSxxx is completely unavailable.
The NB/RSxxx’s fault management provides means to minimize the failures’ effects on the QoS perceived by network users. In general, fault management comprises the fol-lowing functions: • Monitoring the system • Detecting faults • Isolating faults • Generating event reports
The term ’event reports’ includes both failure event reports (FERs) and state change event reports (SCERs).
• Sending event reports to the NB/RSxxx’s local maintenance terminal (LMT) and to the connected OMC-B, such as the Radio Commander (RC)From there, alarms with severities minor, major, and critical are forwarded to NetAct via Itf-N. Major and critical alarms are mapped to dedicated NetAct alarms.
• Localizing faults • Correcting faults
The NB/RSxxx furthermore provides a common log for all failure event reports (FERs) and a log record per each FER. The alarm log is stored in a reset-safe storage area in the NB/RSxxx, i.e. the log will be kept upon NB/RSxxx restarts but not upon power-off, see “Alarm handling after NB/RSxxx reset”. For details about uploading these log files, refer to the “Using Node B Service Terminal” guideline. Additionally, the NB/RSxxx a list containing the NB/RSxxx’s active alarms of severities minor, major, and critical. In contrast to the alarm log, however, this list is neither kept upon NB/RSxxx restarts nor does it contain any alarm history.
The NB/RSxxx can only provide these functions and perform accurate remote fault analysis if it is synchronized with other elements of the UTRAN from operation, admin-istration, and maintenance (OAM) point of view. For an overview on the vendor’s OAM concept, refer to the “WCDMA RAN System Overview”, chapter “Network management architecture”.
298 DN70580522Issue 01A
Troubleshooting Node B
Id:0900d8058022b0c6Confidential
Appendix
With regard to operation and maintenance (O&M) aspects, the NB/RSxxx’s fault man-agement function supports the following two separate parts: • Implementation-specific operation and maintenance
Implementation-specific O&M functions are functions which are actually imple-mented in the NB/RSxxx. They heavily depend both on the NB/RSxxx’s hardware components and on managing its software parts.Within this “Appendix”, section “Generating an alarm” describes the general handling of faults which are subject to implementation-specific O&M.
• Logical operation and maintenanceLogical O&M is the signaling associated with the control of logical resources, such as channels or cells. The RNC owns and controls these resources although they are physically implemented in the NB/RSxxx. Information is thus exchanged between the NB/RSxxx and the RNC via NBAP messages.In the event of a failure in the logical O&M part, the RNC sends a related alarm to the OAM management system (OMC-R). Failures related to logical O&M are:– Cell inoperable– Local cell not available– Downlink common channel (FACH) inoperable– Downlink common channel (PCH) inoperable– Downlink common channel (PCH/FACH) inoperable– Uplink common channel inoperable– HSDPA channel inoperable– HSUPA channel inoperable
g The present troubleshooting manual deals with implementation-specific O&M only.
Generating an alarmThe purpose of generating an alarm is to alert operators about failures which need to be corrected. Alerting operators is done by sending a failure event report to the manage-ment system (LMT/OMC-B). An entry in the NB/RSxxx’s log file is furthermore created.
If a failure occurs in the implementation-specific O&M part of the NB/RSxxx, fault man-agement processes as follows: • Sending failure event reports to the LMT/OMC-B
The NB/RSxxx sends only those reports which contain useful information. In the fol-lowing cases, fault management therefore suppresses reports: failures that are cleared immediately afterwards and reports that would repeat the same information over and over again.
• Sending both failure event reports and state change event reportsFor failures which also change the defective managed object’s (MO) alarm status (ALS) or other state attributes, fault management also sends state change event reports. State change event reports are sent in the event of changes to the opera-tional state (OST), availability status (AVS), and standby status (SBS).
• Logging the alarm event report in a history log in the NB/RSxxx • Storing the alarm event report in the list of active alarms in the NB/RSxxx
This task is done only for new alarm conditions, i.e. only once per alarm. • Running automatic recovery procedures
Examples are provided in section “Equipment fault management”.
DN70580522 Issue 01A
299
Troubleshooting Node B Appendix
Id:0900d8058022b0c6Confidential
Alarm handling after NB/RSxxx resetIn the event of a NB/RSxxx reset, the software cannot guarantee that the failure event report (FER) describing the reason for the reset is reliably sent to the management system. One reason for not sending the FER may be that the connection is already broken. The concept of “last error handling” therefore assures that the reason for the reset is always sent to the management system as soon as the NB/RSxxx will have recovered from the reset.
The last error, containing the main part of the FER, is thus persistently stored (“power-off safe”) in critical situations. Such situations comprise fatal faults and when forwarding the FER to the management system cannot be guaranteed. After NB/RSxxx restart and end of the alignment procedures, the software NB/RSxxx’s fault management applica-tion forwards the FER containing the last error to the management system.
The severity of this corresponding alarm will be warning only because • The fault occurred in the past. • The alarm cannot be cleared in the currently-running NB/RSxxx. • The reason for the reset, i.e. the fault, may no longer exist after the reset.
g NOTE: It may be possible that the alarm is output twice: first, immediately before the NB/RSxxx reset with originally-defined severity (such as critical or major) and then again after NB/RSxxx restart and alignment with severity warning.
Solving and clearing an alarmAlarms which have been raised in consequence of faults have to be solved. Repairing and removing the corresponding fault thus is essential to clear the alarm. The fault clear-ance procedure depends on the actual alarm. In general, however, the following princi-ple differentiation can be made, depending on the type of fault: • Equipment faults are repaired by replacing the defective units with working ones. • Software faults are repaired by means of software patches, database update, or
update of the software load. • Communication faults are cleared by
– Replacing the defective equipment (link interface, etc.)– Removing the cause of noise if this was the reason for raising the alarm
• Quality of service (QoS) alarms are cleared by– Removing the causes that degraded the QoS– Improving the system’s capability to react upon the causes that could result in a
degradation of the QoS • Environmental problems are solved by removing the bad environmental conditions
which led to the relevant alarm, such as high temperature or humidity.
Alarm treatment starts usually at the NetAct or Radio Commander (RC). RC trouble-shooting typically involves: selecting an alarm message from the alarm list that is dis-played on the RC screen and pressing F1 to lead to a troubleshooting procedure that can be carried out remotely from RC. This procedure may solve the fault or gather more symptoms. If it is not possible to solve the fault from RC, the NE documents have to be used to eliminate the fault on site.
300 DN70580522Issue 01A
Troubleshooting Node B
Id:0900d8058022b0c6Confidential
Appendix
This complete troubleshooting procedure is explained in the following figure for a NB/RSxxx fault.
For on-site fault clearance, the error ID of the network element is the starting point. By means of this information the troubleshooting procedure can be found in the trouble-shooting manual (“Troubleshooting Node B”). If necessary a link will be given to the maintenance manual (“Replacing Node B Units”) for a module changing procedure.
As soon has the alarm cause is cleared, fault management sends an alarm event report with perceived severity cleared to the LMT/OMC-B. As a result, the corresponding active alarm (severity minor, major, or critical) is deleted from the NB/RSxxx’s list of active alarms and from the related list in the OMC-B, such as the Radio Commander (RC). Alarms of severity warning are not affected.
218.1.1 Equipment fault managementWhen a fault occurs in a card/module, the NB/RSxxx’s core controller (CC) card typically forces a reset of the alarmed card/module for quick recovery.
In the event of hardware failure, the following general fault detection and recovery actions are taken:1. Sending event reports
– Failure event reports and state change event reports are sent to the LMT/OMC-B.
– Resource status indications are sent to the RNC via NBAP signaling.2. Starting an automatic recovery procedure
DN70580522 Issue 01A
301
Troubleshooting Node B Appendix
Id:0900d8058022b0c6Confidential
– Redundancy switch: when a failure occurs on an active card, the card in standby mode becomes active and takes over the defective card’s operation. For more details on hardware redundancy, refer to section “NB/RSxxx hardware redundancy concept”.
– Resource switch for maintaining calls and Iub link changing: When one card fails, the other cards perform the tasks of the defective one in a load-sharing configuration.
– Automatic reset: Executing the reset of a card reinitialzes the card and clears the alarm. The latter, however, applies only for a subset of alarms whereas for others, the reset does not clear the alarm condition.
3. Handling cells which are down– The NB/RSxxx stops transmission of the amplifier (such as LPA, CAT, RRH).– The affected calls are released.
NB/RSxxx hardware redundancy conceptTo prevent interruptions of operation and assure maximum system reliability, redun-dancy concepts are incorporated in the hardware configuration of the NB/RSxxx. The following redundancy concepts exist, although not each concept may be available for all types of NB/RSxxx: • N/E redundancy
The N/E card redundancy concept uses two units. One of them is active while the other one remains in standby mode. The standby card becomes only active in the event of a failure in the active card.
• Load-sharing redundancyMore than one card/module is used in the system, depending on traffic, capacity, and power. All cards are active in parallel. The failure of one card may decrease the performance of the functionality. There is no total loss, however.
• N+1 redundancyIn the N+1 card redundancy concept, N+1 units are active while only N cards are necessary to perform the full functionality. All cards are equal.
• Diversity configuration (no redundancy)Only one card or module operates in the system, i.e. there is no redundancy. One path of this card/module has diversity configuration. A failure in one of the diversity paths decreases the performance. Services, however, are maintained.
The possible redundancy configuration depends on the actual platform which is used: • For NB-420, refer to the “NB-420 Product Description”. • For NB-440 and NB-441, refer to the “NB-440/NB-441 Product Description”. • For NB-860 or NB-861, refer to the “NB-860/NB-861 Product Description”. • For NB-880 and NB-881, refer to the “NB-880/NB-881 Product Description”. • For RSSU-380, refer to the “RSSU-380/RRHs Product Description”. • For RS-381, refer to the “RS-381/RRHs Product Description”. • For RS-880, refer to the “RS-880/RRHs Product Description”.
218.1.2 Transport network fault managementThis section deals with the fault and alarm management for the NB/RSxxx’s transport network domain.
Atomic functions in the fault management detect failure indications (anomalies) which, in turn, are input signals for the alarm management. The failure indications are routed
302 DN70580522Issue 01A
Troubleshooting Node B
Id:0900d8058022b0c6Confidential
Appendix
through internal filters of the NB/RSxxx. These filters process the anomalies, add infor-mation, and generate appropriate alarms. Alarm management correlates relevant alarms and propagates alarms to the management system.
Fault and alarm management at the NB/RSxxx’s transport domain distinguishes between three basic indications and monitors them. The indications’ definitions are in accordance with “Bellcore GR-1248-CORE, Section 6.1“: • Anomaly (CRC error, OOF, out of cell delineation, etc.)
Anomalies are discrepancies between the current and the desired characteristics of an item. Normally, anomalies are determined by means of one or more detectable events. An anomaly is the first indicator for trouble in the network. If the density of anomalies is sufficiently high enough for a small fraction of a second, fault manage-ment declares a defect.
• Defect (LOS, LOF, etc.)Defects are limited interruptions in an item’s ability of performing the required func-tion. The item’s decrease of performance is caused by successive anomalies which are considered as a defect.When a defect is declared, fault management takes the following measures:– Generation of inband indications, such as AIS and RDI– Fault propagation to the upper layer
• Failure (AIS, RDI, etc.)Failures are defined as the termination of an item’s ability of performing the required function. When a defect was detected and has persisted for a certain time, fault management declares a failure and generates an alarm.
Alarm correlation at the transport network layer (TNL)
g NOTE: Alarm correlation applies for only one NB/RSxxx but not for various NB/RSxxxs which are monitored by one specific network management system such as the RC.
Four sub-features (filters) of the NB/RSxxx’s transport network alarm management take care of keeping the number of alarms sent to the LMT or OMC-B as low as possible. • Fault persistency
The NB/RSxxx’s TNL fault management checks whether defects, which cause alarms, remain present. On the one hand, if a fault cause continuously lasts for a certain time, fault management declares a defect. On the other hand, if a fault cause is absent for a certain time, fault management clears the defect.The fault persistency thus allows only continuous defects being propagated to the LMT/OMC-B.
• Fault priorizationAll defects at the transport network layer (TNL) have determined priorities. Alarm management reports only the defect with the highest priority but not defects which occur only in consequence to this defect.Fault priorization thus reduces the number of alarms which provide only redundant information and/or are caused by defects with higher priority.
DN70580522 Issue 01A
303
Troubleshooting Node B Appendix
Id:0900d8058022b0c6Confidential
• Fault propagationDefects occurring at lower layers are propagated to upper layers to initiate conse-quent actions at the higher layer. These actions include AIS and RDI insertion.Fault propagation thus provides information about defects at the respective lower layer’s resources to all transport network layers. As a consequence, upper layers retrieve information when their own services could become degraded.The propagation is also helpful for operators with regard to failure cause analysis.
• State propagationAs a consequence of the fault propagation, fault and alarm management also promotes the state information to the upper layer and to higher applications.State propagation thus provides means for the operator to verify the layer which is degraded and the corresponding layers which are also affected.
Benefits of the alarm correlationThe alarm correlation at the transport network layer drastically reduces the amount of alarm notifications at the Itf-B. This is achieved by alarming only these defects which contain useful information. Fault and alarm management suppresses all other defects which are caused by the initial defect, however.
As a consequence, operators get a better overview of the basic failure cause and can take troubleshooting tasks much quicker. Furthermore, the load of the transmission network and of the management system (LMT/OMC-B) is reduced.
304 DN70580522Issue 01A
Troubleshooting Node B
Id:0900d8058022b0c6Confidential
Appendix
218.2 Mapping of NB/RSxxx alarms to NetAct alarmsIn the present release, alarms generated by the NB/RSxxx are also forwarded from the RC to NetAct via the Itf-N. Table 1 shows the mapping of the NB/RSxxx alarms to cor-responding NetAct alarms.
NetAct alarm(<ID> – <Name>)
NB/RSxxx alarm(<ID> – <Name>)
92001 – THIS IS A NODEB2 ALARM 200658 – Transmit bandwidth limit for NBAP reached
200659 – Core Controller overload protection activated
200905 – VSWR alarm Low
200907 – RX alarm Low
200909 – TMA switched off, but not defective.
200910 – TMA feeder alarm
200911 – TMA DC alarm
200915 – Site input alarm detected
200916 – Rack Door open
200920 – High temperature of PA
200924 – Input power level of LPA too high but LPA can still hold its RF specification
200986 – Temperature out of range in upper direction
200994 – Hardware Failure
200997 – Lower Temperature Limit (Ht0) reached
200998 – Temperature out of range in lower direction
201001 – RET power off
201002 – RET feeder alarm
201003 – RET hardware alarm
201004 – ALD communication error
201005 – RET is not calibrated
201006 – RET is not scaled
201007 – RET lost position
201008 – RET received wrong configuration data
201016 – Non-fatal internal LVDS failure
201017 – Digital input power level too high, but gain reduced
Table 1 Mapping of NB/RSxxx alarms to NetAct alarms
DN70580522 Issue 01A
305
Troubleshooting Node B Appendix
Id:0900d8058022b0c6Confidential
92001 – THIS IS A NODEB2 ALARM 201020 – Loss of single DRIF interface detected
201022 – Alignment of file data has failed
201023 – Bad signal quality of single DRIF interface detected
201029 – MEF blocked
201031 – Wrong combination of licensed cards.
201032 – Not all cells are licensed.
201033 – PID could not be read or is corrupted – non-fatal
201036 – RRHs unable to establish communication links with the expected number of PSRs.
201037 – ALD unspecified error
201038 – Resource conflict between CP and OAM
201041 – Test channels have been lost
201044 – Non fatal configuration failure
202007 – A scanner could not be initialised
202008 – The temporary measurement results could not be stored
202009 – Unable to request measurement results
202010 – The ScanCo could not be initialised
202011 – The final results files could not be generated
202068 – Signal Label Mismatch Indication on STM1 Physical Link
202070 – Signal Degrade Indication on STM1 Physical Link
202072 – Alarm Indication Signal on an ATM VC
202073 – Remote Defect Indication on an ATM VC
202075 – Alarm Indication Signal on an ATM VP
202076 – Remote Defect Indication on an ATM VP
202078 – Loss Of Delay Synchronisation on IMA Link
202079 – Loss Of IMA Frame on IMA Link
NetAct alarm(<ID> – <Name>)
NB/RSxxx alarm(<ID> – <Name>)
Table 1 Mapping of NB/RSxxx alarms to NetAct alarms (Cont.)
306 DN70580522Issue 01A
Troubleshooting Node B
Id:0900d8058022b0c6Confidential
Appendix
92001 – THIS IS A NODEB2 ALARM 202080 – Remote Failure Indicator on IMA Link
202081 – IMA Tx link is detected as mis-connected
202082 – IMA Rx link is detected as mis-connected
202083 – Tx fault declared at the NE on IMA Link
202084 – Rx fault declared at the NE on IMA Link
202085 – FE has reported Tx-Unusable on IMA Link
202086 – FE has reported Rx-Unusable on IMA Link
202097 – Loss of Continuity detected on an ATM VP
202110 – A file upload is pending
202506 – NodeB system clock in holdover mode
202507 – NodeB system clock in medium accuracy
92002 – THIS IS A NODEB2 ALARM 200707 – A warning occurred in the nbDatabase
200944 – FTP put failed
200945 – FTP manage failure
200949 – Internal CORBA call failed
200953 – CAN bus off
200980 – Invalid MO
200981 – MO not mounted
200982 – Invalid command
200983 – Invalid parameter in command
200984 – Firmware download access file error
200985 – CAN transaction error
200987 – Hardware parameter invalid
200988 – Response unknown
201009 – A mounted card is not used to its full capacity
201014 – Standby CC forced to become active due to unreachable active CC.
201015 – Preparation of data to be aligned has failed
201030 – Invalid hardware capacity licensing value.
201048 – Non fatal BB software failure
201049 – Non fatal DSP failure
NetAct alarm(<ID> – <Name>)
NB/RSxxx alarm(<ID> – <Name>)
Table 1 Mapping of NB/RSxxx alarms to NetAct alarms (Cont.)
DN70580522 Issue 01A
307
Troubleshooting Node B Appendix
Id:0900d8058022b0c6Confidential
92002 – THIS IS A NODEB2 ALARM 202074 – SSCOP Failure Indication on an ATM VC used by ALCAP or NBAP
202098 – CRC4 not used by FE reported on E1TTP
202106 – Software activation failed
202107 – Database activation failed
202108 – Reliable software started without prior explicit activation
202109 – Reliable database started without prior explicit activation
202358 – CAN received an unexpected message
202406 – ALCAP protocol error
202431 – ALCAP transaction to RNC initiated by trans-port timed out
202432 – ALCAP transaction to RNC initiated by NBAP timed out
202433 – Configuration misalignment between RNC and CPA
202434 – RNC Establish Request message received which is invalid or cannot be handled
NetAct alarm(<ID> – <Name>)
NB/RSxxx alarm(<ID> – <Name>)
Table 1 Mapping of NB/RSxxx alarms to NetAct alarms (Cont.)
308 DN70580522Issue 01A
Troubleshooting Node B
Id:0900d8058022b0c6Confidential
Appendix
92003 – THIS IS A NODEB2 ALARM 202014 – The first sccpchUsageRatio Quality of Service alarm has occurred
202015 – The second sccpchUsageRatio Quality of Service alarm has occurred
202016 – The first prachUsageRatio Quality of Service alarm has occurred
202017 – The second prachUsageRatio Quality of Service alarm has occurred
202018 – The first cpUsageRatio Quality of Service alarm has occurred
202019 – The second cpUsageRatio Quality of Service alarm has occurred
202020 – The first prachCrciFailures Quality of Service alarm has occurred
202021 – The second prachCrciFailures Quality of Service alarm has occurred
202022 – The first bbUsageRatioLicense Quality of Service alarm has occurred
202023 – The second bbUsageRatioLicense Quality of Service alarm has occurred
202024 – The first bbUsageRatioHw Quality of Service alarm has occurred
202025 – The second bbUsageRatioHw Quality of Service alarm has occurred
202026 – The first e1Crc Quality of Service alarm has occurred
202027 – The second e1Crc Quality of Service alarm has occurred
202028 – The first vcUsageRatio Quality of Service alarm has occurred
202029 – The second vcUsageRatio Quality of Service alarm has occurred
92004 – NODEB SYSTEM START-UP MALFUNC-TION DUE TO SOFTWARE/HARDWARE PROBLEM
200506 – NodeB system start-up malfunction due to software/hardware problem
92005 – SYSTEM HALT DUE TO SOFTWARE WATCHDOG DETECTED PROBLEM
200507 – System halt due to software watchdog detected problem
92006 – SYSTEM HALT DUE TO DETECTED APPLI-CATION PROCESS ERROR
200508 – System halt due to detected application process error
NetAct alarm(<ID> – <Name>)
NB/RSxxx alarm(<ID> – <Name>)
Table 1 Mapping of NB/RSxxx alarms to NetAct alarms (Cont.)
DN70580522 Issue 01A
309
Troubleshooting Node B Appendix
Id:0900d8058022b0c6Confidential
92007 – SYSTEM HALT DUE TO DETECTED HARDWARE EXCEPTION
200509 – System halt due to detected hardware exception
92008 – SYSTEM HALT DUE TO DETECTED SOFTWARE LOADING MALFUNCTION
200510 – System halt due to detected software loading malfunction
92009 – IUB LINK BROKE DOWN 200656 – Iub link broke down
92010 – SSCOP SEND OVERRUN 200657 – SSCOP send overrun
92011 – AN ERROR OCCURRED IN THE NBDATA-BASE
200706 – An error occurred in the nbDatabase
92012 – VSWR ALARM HIGH 200906 – VSWR alarm High
92013 – RX ALARM HIGH 200908 – RX alarm High
92014 – FAN UNIT FAILED 200914 – Fan unit failed
92015 – PA COMBINER INTERFACE FAULT 200918 – PA combiner interface fault
92016 – FAILURE IN THE DC SUPPLY OF PA 200919 – Failure in the DC supply of PA
92017 – OVER TEMPERATURE OF PA 200921 – Over temperature of PA
92018 – RF PERFORMANCE NOT BEING MET DUE TO BAD LINEARISATION
200922 – RF performance not being met due to bad lin-earisation
92019 – INTERNAL FAILURE OF PA DETECTED 200923 – Internal failure of PA detected
92020 – INPUT POWER LEVEL OF PA TOO HIGH 200925 – Input power level of PA too high
92021 – CPU FAILURE OF BASEBAND CARD 200926 – CPU failure of baseband card
92022 – VOLATILE MEMORY FAILURE OF BASEBAND CARD
200927 – Volatile memory failure of baseband card
92023 – NON-VOLATILE MEMORY FAILURE OF BASEBAND CARD
200928 – Non-volatile memory failure of baseband card
92024 – DSP FAILURE 200929 – DSP failure
92025 – FPGA FAILURE 200931 – FPGA failure
92026 – CONTROL FPGA FAILURE 200932 – Control FPGA failure
92027 – EXTERNAL TIMING SIGNAL FAILURE 200933 – External timing signal failure
92028 – FAILURE OF THE RF PART OF THE TRX 200934 – Failure of the RF part of the TRX
92029 – LVDS FAILURE 200935 – LVDS Failure
92030 – LOCAL BUS FAILURE AROUND THE CPU 200936 – Local bus failure around the CPU
92031 – FTP CONNECTION FAILURE 200937 – FTP connection failure
92032 – CRC ERROR DURING SOFTWARE IMAGE CHECK
200938 – CRC error during software image check
92033 – STATIC CONFIGURATION FILE CRC CHECK FAILED
200939 – Static configuration file CRC check failed
NetAct alarm(<ID> – <Name>)
NB/RSxxx alarm(<ID> – <Name>)
Table 1 Mapping of NB/RSxxx alarms to NetAct alarms (Cont.)
310 DN70580522Issue 01A
Troubleshooting Node B
Id:0900d8058022b0c6Confidential
Appendix
92034 – SOFTWARE ACTIVATION FAILED 200940 – Software activation failed
92035 – INTERNAL CLOCK FAILURE 200941 – Internal clock failure
92036 – CONFIGURATION FILE INCONSISTENT 200942 – Configuration file inconsistent
92037 – IOR FILE INCONSISTENT 200943 – IOR file inconsistent
92038 – STILL ALIVE SUPERVISION FAILURE 200946 – Still alive supervision failure
92039 – FAILURE IN THE DC SUPPLY OF DUAMCO 200947 – Failure in the DC supply of DUAMCO
92040 – CORBA COMMUNICATION FAILED 200948 – CORBA communication failed
92041 – TIMEOUT FOR REQUEST OR MODIFICA-TION
200950 – Timeout for request or modification
92042 – STATUS NOTIFICATION UNDEFINED 200951 – Status notification undefined
92043 – MAXIMUM NUMBER OF RESETS EXCEEDED
200952 – Maximum number of resets exceeded
92044 – NO MESSAGE RESPONSE ON CAN 200954 – No message response on CAN
92045 – MOUNT SUPERVISION FAILURE 200955 – Mount supervision failure
92046 – WATCH DOG TIMER EXPIRED 200956 – Watch dog timer expired
92047 – INTERNAL CAN PROCESSING FAILURE 200957 – Internal CAN processing failure
92048 – TIMER FOR THE RESET SUPERVISION EXPIRED
200958 – Timer for the reset supervision expired
92049 – MISSING RESPONSE FROM BASEBAND CARD
200959 – Missing response from baseband card
92050 – INVALID RESPONSE FROM BASEBAND CARD
200960 – Invalid response from baseband card
92051 – FIRMWARE DOWNLOAD FAILURE 200961 – Firmware download failure
92052 – NO CORBA PROXY AVAILABLE FOR LRU 200989 – No CORBA proxy available for LRU
92053 – NO STILL ALIVE RESPONSE FROM LRU 200990 – No still alive response from LRU
92054 – DUPLEX ERROR 200991 – Duplex error
92055 – SOFTWARE ERROR 200992 – Software error
92056 – UNEXPECTED ALARM STATUS BIT 200993 – Unexpected alarm status bit
92057 – HIGH TEMPERATURE LIMIT (HT3) REACHED
200995 – High Temperature Limit (Ht3) reached
92058 – CRITICAL TEMPERATURE LIMIT (HT4) REACHED
200996 – Critical Temperature Limit (Ht4) reached
92059 – UNEXPECTED LOSS OF UNLOCKED LRU 200999 – Unexpected loss of unlocked LRU
92060 – AN INCOMPATIBLE CARD IS MOUNTED 201010 – An incompatible card is mounted
92061 – ALIGNMENT OF STANDBY CC FAILED 201011 – Alignment of standby CC failed
NetAct alarm(<ID> – <Name>)
NB/RSxxx alarm(<ID> – <Name>)
Table 1 Mapping of NB/RSxxx alarms to NetAct alarms (Cont.)
DN70580522 Issue 01A
311
Troubleshooting Node B Appendix
Id:0900d8058022b0c6Confidential
92062 – TIMEOUT FOR CONNECTION TO STANDBY CC
201012 – Timeout for connection to standby CC.
92063 – CONNECTION FAILURE TO STANDBY CC 201013 – Connection failure to standby CC.
92064 – THE LRU COULD NOT PROCESS A MESSAGE FROM CC
201018 – The LRU could not process a message from CC
92065 – GAIN BELOW THRESHOLD 201019 – Gain below threshold
92066 – BAD SIGNAL QUALITY OF ALL DRIF INTER-FACES DETECTED
201024 – Bad signal quality of all DRIF interfaces detected
92067 – PID COULD NOT BE READ OR IS COR-RUPTED
201025 – PID could not be read or is corrupted
92068 – LRU SENT ILLEGAL PARAMETER 201026 – LRU sent illegal parameter
92069 – LRU COULD NOT PROCESS A MESSAGE FROM CC CONTAINING DATA FROM DB
201027 – LRU could not process a message from CC containing data from DB
92070 – NODEB SYSTEM CLOCK HARDWARE FAILURE
201028 – NodeB system clock hardware failure
92071 – BOOSTERS FAN UNIT FAILED 201034 – Boosters Fan unit failed
92072 – MEF COMPLETELY BLOCKED 201035 – MEF completely blocked
92073 – INCONSISTENCY BETWEEN HARDWARE LICENSE AND CONFIGURATION
201039 – Inconsistency between hardware license and configuration.
92074 – WRONG CABLING OF LRU DETECTED 201040 – Wrong cabling of LRU detected.
92075 – INCOMPATIBLE FIRMWARE 201042 – Incompatible Firmware
92076 – MISSING SOFTWARE IMAGE 201043 – Missing software image
92077 – FATAL HARDWARE FAILURE 201045 – Fatal hardware failure
92078 – NO ATM CONNECTION FOR OAM AUTO-CONFIGURATION
201046 – No ATM connection for OAM Autoconfigura-tion
92079 – FATAL BB SOFTWARE FAILURE 201047 – Fatal BB software failure
92080 – LOSS OF SIGNAL ON PHYSICAL LINK 202056 – Loss Of Signal on Physical Link
92081 – LOSS OF FRAME ON PHYSICAL LINK 202057 – Loss Of Frame on Physical Link
92082 – LOSS OF CELL DELINEATION ON PHYSICAL LINK
202058 – Loss Of Cell Delineation on Physical Link
92083 – ALARM INDICATION SIGNAL ON PHYSICAL LINK
202059 – Alarm Indication Signal on Physical Link
92084 – REMOTE ALARM INDICATION ON PHYSICAL LINK
202060 – Remote Alarm Indication on Physical Link
92085 – LOSS OF MULTIFRAME ALARM INDICA-TION ON E1 PHYSICAL LINK
202061 – Loss Of MultiFrame Alarm Indication on E1 Physical Link
NetAct alarm(<ID> – <Name>)
NB/RSxxx alarm(<ID> – <Name>)
Table 1 Mapping of NB/RSxxx alarms to NetAct alarms (Cont.)
312 DN70580522Issue 01A
Troubleshooting Node B
Id:0900d8058022b0c6Confidential
Appendix
92086 – LINE ALARM INDICATION SIGNAL INDICA-TION ON STM1 PHYSICAL LINK
202062 – Line Alarm Indication Signal Indication on STM1 Physical Link
92087 – LINE REMOTE DEFECT INDICATION ON STM1 PHYSICAL LINK
202063 – Line Remote Defect Indication on STM1 Physical Link
92088 – PATH LOSS OF POINTER INDICATION ON STM1 PHYSICAL LINK
202064 – Path Loss Of Pointer Indication on STM1 Physical Link
92089 – PATH ALARM INDICATION SIGNAL ON STM1 PHYSICAL LINK
202065 – Path Alarm Indication Signal on STM1 Physical Link
92090 – PATH REMOTE DEFECT INDICATION ON STM1 PHYSICAL LINK
202066 – Path Remote Defect Indication on STM1 Physical Link
92091 – EXCESSIVE BIT ERROR RATE INDICATION ON STM1 PHYSICAL LINK
202071 – Excessive Bit Error Rate Indication on STM1 Physical Link
92092 – ALCAP PVC OUT OF SERVICE INDICATION 202077 – ALCAP PVC Out Of Service Indication
92093 – STARTUP FE REPORTED ON IMA GROUP 202087 – Startup FE reported on IMA Group
92094 – CONFIG ABORT REPORTED ON IMA GROUP
202088 – Config Abort reported on IMA Group
92095 – CONFIG ABORT FE REPORTED ON IMA GROUP
202089 – Config Abort FE reported on IMA Group
92096 – INSUFFICIENT LINKS REPORTED AT NE ON IMA GROUP
202090 – Insufficient Links reported at NE on IMA Group
92097 – INSUFFICIENT LINKS AT FE REPORTED ON IMA GROUP
202091 – Insufficient Links at FE reported on IMA Group
92098 – GROUP BLOCKED AT FE REPORTED ON IMA GROUP
202092 – Group Blocked at FE reported on IMA Group
92099 – TIMING SYNCH ERROR REPORTED ON IMA GROUP
202093 – Timing Synch error reported on IMA Group
92100 – THE NEAR END IMA HAS DETECTED AN INVALID VERSION SET BY THE FAR END
202095 – The Near End IMA has detected an invalid version set by the Far End
92104 – A NECESSARY RESOURCE IS MISSED 202360 – A necessary resource is missed
92105 – CPA TO RNC COMMUNICATION (SOCKET) PROBLEMS
202435 – CPA to RNC communication (socket) problems
92106 – SYSTEM CALL UNSUCCESSFUL 262041 – System call unsuccessful
92107 – UNEXPECTED SOFTWARE ERROR 262042 – Unexpected software error
92108 – ERROR FROM DEVICE DRIVER RECEIVED 262043 – Error from device driver received
92109 – NOT ENOUGH MEMORY TO INITIALIZE SOFTWARE
262044 – Not enough memory to initialize software
92110 – MEMORY ALLOCATION FAILURE 262045 – Memory allocation failure
NetAct alarm(<ID> – <Name>)
NB/RSxxx alarm(<ID> – <Name>)
Table 1 Mapping of NB/RSxxx alarms to NetAct alarms (Cont.)
DN70580522 Issue 01A
313
Troubleshooting Node B Appendix
Id:0900d8058022b0c6Confidential
92111 – UNEXPECTED EXCEPTION HANDLING 262046 – Unexpected exception handling
92112 – UNCAUGHT EXCEPTION HANDLING 262047 – Uncaught exception handling
NetAct alarm(<ID> – <Name>)
NB/RSxxx alarm(<ID> – <Name>)