Ë µÃ ÷Ê éË µÃ ÷Ê é
R
KEC-30
KEC-30
ELECTRONIC FLUXGATE COMPASS
OPERATOR`S MANUAL
FEATURES 2
SYSTEM CONFIGURATION 3
1 OPERATION 4
1.1 Controls 4
1.2 Turning the power on/off 5
1.3 Panel Illumination, Display contrast 5
1.4 Display 6
1.5 Function setting 9
1.5.2 Auto Heading Adjust 10
1.5.3 Manual Heading Adjust 12
1.5.4 Heading Alignment Setting 12
1.5.5 Language Setting 13
1.5.6 Time Setting 13
1.5.7 Output Setting 14
FOREWORD 1
2 INSTALLATION & MOUNTING CONSIDERATIONS 16
2.1 Fluxgate Compass Unit 16
2.1.1 16Outdoor installation
2.1.2 Desktop mounting 17
2.1.3 Bulkhead mounting 18
2.2 Display Unit 19
2.2.1 Desktop, Overhead mounting 20
2.3 Wiring 22
2.2.2 Flush mount 21
1.5.8 Factory Default Setting 15
1.5.1 Heading Display 9
CONTENTS
3 MAINTENANCE, TROUBLESHOOTING 23
3.1 Preventive maintenance 23
3.2 Troubleshooting 24
INTERCONNECTION DIAGRAM 27
DISPLAY UNIT SIZE 29
FLUXGATE SENSOR SIZE 30
CONNECTING CABLES 28
C-BRACKET SIZE CHART 31
THE SPECIFICATIONS OF KEC-30 25
CONTENTS
SAFETY INSTRUCTIONS
WARNING
Do not open the equipment.
Only qualified personnel should work
inside the equipment.
Do not disassemble or modify the
equipment.
Fire,electrical shock or serious injury
can result.
Immediately turn off the power at
the switchboard if the equipment is
emitting smoke or fire.
Continued use of the equipment can
cause fire or electrical shock.Contact
a ONWA agent for service.
Use the proper fuse.
Use of a wrong fuse can damage the
equipment or cause fire.
Be sure the power supply is compatible with the equipment.
Incorrect power supply may cause the
equipment to overheat.
The useable temperature range for the antenna unit is -25 to 70 ; -15 to 55 for the display unit.
Use of the equipment out of those
ranges may damage the equipment.
Safety Instructions for the Operator Safety Instructions for the Installer
WARNINGDo not open the cover unless totallyfamiliar with electrical circuits andservice manual.
Improper handling can result in
electrical shock.
Turn off the power at the switchboardbefore beginning the installation.
Fire or electrical shock can result if the
power is left on.
Be sure that the power supply iscompatible with the voltage rating of the equipment.
Connection of an incorrect power
supply can cause fire or equipment
damage.
Use the proper fuse.
Use of a wrong fuse can damage the
equipment or cause fire.
NOTICE
Observe the following compass safedistances to prevent interference to a magnetic compass:
0.4 m 0.3 m
1.2 m 1.2 m
Display unit
Standard Compass
SteeringCompass
Processor
FOREWORD
Thanks you for purchasing the ONWA KEC-30
Your equipment is designed and constructed to meet the rigorous demands of
the marine environment. However, no machine can perform its intended
function unless properly installed and maintained.
Please carefully read and follow the operation, installation and maintenance
procedures set forth in this manual.
We would appreciate feedback from you.
Thank you for considering and purchasing ONWA.
Electronic Fluxgate Compass.
1
The KEC-30 is a designed with ONWA`s advanced
LCD high definition display technology. This compass a wide range
of applications for any type of ships
The main features are
Perfect for use as heading sensor for Radar/ARPA, AIS, ECDIS,
scanning sonar
There are no mechanical parts such as gimbals or rotating motor, thus the
compass is free from routine maintenance
Chinese and English menu display
Electronic Fluxgate Compass
It uses a fluxgate magnetic sensor in conjunction with a microprocessor to
display accurate heading.
The KEC-30 can correct magnetic deviation manually or automatically.
provides
at sea and vehicles on land.
2
FEATURES
SYSTEM CONFIGURATION SYSTEM CONFIGURATION
The KEC-30 consists of a Display unit and a Fluxgate Sensor unit.
Fluxgate Sensor unit
KFG-25
Display unitKEC-30
External GPS data input
The heading signal output
DC10.5V~40V
KEC-30 ELECTRONIC COMPASS
MENU
PWRKEC-30
ENT
ESC DIM
DISP
3
1. OPERATION1. OPERATION
MENU: Open Menu
Omnipad: Select the menu item
ENT: To identify or modify the selection
KEC-30 ELECTRONIC COMPASS
MENU
PWRKEC-30
ENT
ESC DIM
DISP DIM: Adjust LCD brightness and contrast
DISP: Select the display mode
PWR: To switch on/off the unit
4
ESC: Exit the menu item.
1.1 Controls
1.3 Panel Illumination, Display contrast
1. Press the [DIM] key.
Dialog box for adjustment of panel illumination, display contrast
2. Press o r to ad just LC D dis play brightness and panel illumination.
3. Press or to adjust
4. Press the [ESC] key
LCD display contrast.
to confirm and exit.
1.2 Turning the power on/off
Turning the Power On, press [PWR] once to switch on the unit with a
"beep" sound.
Turning the Power Off, Press and hold [PWR] key until the unit turn off.
5
BRILL (1 8)
CONTRAST 2
32
(0 63)
EXIT: [ESC]
R
Electronic Fluxgate Compass
KEC-30
Ver : 1.0
TURNING OFFIN 3 SEC
1.4 Display
There are three display screen, press the [DISP] key to cycle.
6
210 240
W
300
330
N
30
N
60
E
120
150
S
HDT:
224SOG:
COG:
N 22 45.108 E 115 47.203
211
0 4 Kt
224220 230 240 250 260
COG:
kt
HDT:
200 210
SOG:
0 4
3D 2011-01-31 03:36
211
HDT:
COG:SOG:
kt
N 22 45.108 E 115 47.203
2243D 2011-01-31 03:36
0 4 211
3D 2011-01-31 03:36
of display
The shows , date, time
and position-fixing status.
Modes
Navigation data display
navigation data display magnetic heading, COG, SOG
7
Note: beside the a NMEA0183 input is needed for displaying
all other navigation data.
magnetic heading
Date
Course Over Ground
Position data
Speed Over Ground
Location Status Time
Boat's headingHDT:
COG:SOG:
kt
N 22 45.108 E 115 47.203
224
No external data input display
When not connected to an external GPS unit. Navigation data will not be displayed
to show only the current .magnetic heading
HDG:
COG:SOG:
kt
224
No navigation data display screen
0 4 211
Compass display
The compass display shows heading by compass direction. The compass rotates
with heading.
Steering display
The steering display shows heading in digital and analog form. SOG and COG
are also indicated.
Azimuth Scale
Heading tag
8
224220 230 240 250 260
COG:
kt
HDT:
200 210
SOG:
210 240
W
300
330
N
30
N
60
E
120
150
S
HDT:
224SOG:
COG:
N 22 45.108 E 115 47.203
0 4
3D 2011-01-31 03:36
211
211
0 4 kt
1.5 Function setting
Menu function provides automatic and manual orientation rectification azimuth
Angle, language, fixed supplement, time setting, the setting, etc.
1.5.1 Heading Display
,
orientation.
factory default
In the menu select "HEADING DISPLAY" and press [ENT] key.
The following window appears:
Choose when TURE, If external input NMEA data contain Lon/Lat information
KEC30 would use it to calculate "Magnetic Variation" to show HDT direction
otherwise show HDG direction.
Choose when MAGNETIC whether Input any voyage data Are show HDG
9
MENU
AUTO HEADING ADJUST
MANUAL HEADING ADJUST
HEADING ALIGNMENT SETTING
LANGUAGE SETTING
TIME SETTING
OUTPUT SETTING
FACTORY DEFAULT SETTING
HEADING DISPLAY TRUE
MENU
AUTO HEADING ADJUST
MANUAL HEADING ADJUST
HEADING ALIGNMENT SETTING
LANGUAGE SETTING
TIME SETTING
OUTPUT SETTING
FACTORY DEFAULT SETTING
HEADING DISPLAY MAGNETIC
TRUE
AUTO HEADING ADJUST
Auto heading adjusting !Please keep constant speed lessthan 2 minutes for each turn
Cancel [ESC] OK [ENT]
1.5.2 Auto Heading Adjust
In the menu select and press [ENT] key.
The following window appears:
The compass has been calibrated during manufacture. This calibration will be
satisfactory for almost all installations. If you have a steel vessel, or some
other factor which causes the compass to perform poorly, the calibration
procedure will adjust compass characteristics to compensate.
The calibration should only be done if the compass is known to be inaccurate.
If the KEC-30 display as constant offset (e.g. the compass reads 3 degrees
high on all bearings), simply rotate the Fluxgate Sensor case to align
bearings with the ships compass. It is not necessary to re-calibrate the
compass as described below.
If the KEC-30 has inconsistent variation on different headings, the following
calibration procedure can be carried out. This procedure should only be done
in calm waters with adequate sea room.
"AUTO HEADING ADJUST"
10
If correction fails the following message appear:
The message goes away after 6 seconds.
In case of correction fails repeat the above steps until the correction is successful.
Press [ENT] to confirm make corrections, return to the main screen message
will appear to make corrections, while the main screen of data per second
update.
210 240
W
300
330
N
30
N
60
E
120
150
S
HDG:
224SOG:
COG:
Auto heading adjustment failed!
11
210 240
W
300
330
N
30
N
60
E
120
150
S
HDG:
224SOG:
COG:
Auto heading adjusting....
0 4 kt
211
210 240
W
300
330
N
30
N
60
E
120
150
S
HDG:
224SOG:
COG:
Auto heading adjustment success!
0 4 kt
211
0 4 kt
211
Steer the vessel in clockwise direction with constant speed less than 2
minutes per each circle until the following correction success message appear.
If correction success the following message appear:
1.5.3 Manual Heading Adjust
Manual is a supplement to the type of single orientation
parabola 10 degrees. But this method could
Compensation
only be done by
qualified personnel.
to adjacent
1. In the menu select and press [ENT] key.
The following window appears:
"MANUAL HEADING ADJUST"
2. Use up, down key to hen use
left, right key to increase or decrease the
select the direction angle need to be modified, t
number of angle in Degree. The
highest may adjust 10 .
3. Press [ENT] key to save.
Note:
shows each azimuth are unlikely to maintain consistent.
Anyway ship's magnetic compass and electronic fluxgate compass
Cancel [ESC] OK [ENT]
MANUAL HEADING ADJUST
120 +00150 +00180 +00210 +00
240 +00270 +00300 +00330 +00
0 +0030 +0060 +0090 +00
1.5.4 Heading Alignment Setting
Adjustment of heading might be needed during the installation. Usually a fixed
error in all direction would exist. It is due to the mechanical error when fixing
the fluxgate sensor KFG-25. The function "Degree Amend" is used to correct
this error.
select "HEADING ALIGNMENT SETTING"1. In the menu and press
[ENT] key. The following window appears:
2.
3. Press or to
4. Press [ENT] key
Move the cursor to the corresponding field.
change the direction and angle in degree.
The highest may adjust 99 .
to save or press [ESC] to quit without save.
Cancel [ESC] OK [ENT]
Heading alignment setting
224 0 (224 )0+
12
2.
3. Press [ENT] key t
Move the cursor to "English" or "Chinese"
o confirm save or press [ESC] to quit without save.
13
TIME SETTING
Cancel [ESC] OK [ENT]
+ 00:00
1.5.6 Time Setting
When the equipment connect GPS data, can display the time on the
In the menu
1. In the menu option to and press [ENT] key.
The following window appears:
external
Navigation data display mode.
"TIME SETTING" to enter the corresponding time difference.
select "TIME SETTING"
2. Press or key to move the cursor
3. Press or key to modify the
4. Press [ENT] key .
Note: If the change successful. The UTC in the top right corner will turn
into LTC.
to the field need to be modified.
time difference.
to save or press [ESC] to quit without save
Cancel [ESC] OK [ENT]
LANGUAGE SETTING
ENGLISH
1.5.5 Language Setting
Suitable for different users. Can choose Chinese / English display menus.
1. In the menu options and press [ENT] key.
The following window appears:
, select "LANGUAGE SETTING"
14
1.5.7 OUTPUT SETTING
OUTPUT : 1 X NMEA0183: HDG, HDT, HDM
a) Output data includes the following three
HDT: True heading
HDM: Magnetic heading
HDG: Magnetic heading & Magnetic variation value
Cancel [ESC] OK [ENT]
OUTPUT SETTING
HDT
4800 9600 19200
38400
25ms
Type
Baud rate
Interval
HDM HDG
100ms 200ms
1000ms
b)
Three types of outputs can select singly or output together ,the optional
interval is 25ms, 100ms, 1,000ms(1s), The standard interval is 200ms,
three can output together .
c) 48
The optional speed of output, the standard is 00, the optional one is
9600, 19200 and 38400
1000
4800
9600
19200
38400
25
100
200
1000
25
100
200
1000
100
200
1000
25
25
100
200
Relation baud rate and output interval
Baud rate Output interval Available sentences
No output
Up to two sentences canbe output.
Up to three sentences canbe output
HDT or HDM
Up to three sentences canbe output
Up to two sentences canbe output.
Up to three sentences canbe output.
Note: When an error message occurs, the above sentences
may be changed.
1.5.8 Default Settings
1. In the menu options and press
[ENT] key. The following window appears:
Factory
For any reason need to reset all settings to factory default setting you can do
as following instruction.
to select "FACTORY DEFAULT SETTING"
2. Press the [ENT] key to load factory default setting or press [ESC] to quit
without any change.
Note: When you select to load factory default setting all saved settings
would be cleared. This action can not reversible.
FACTORY DEFAULT
Restore tofactory default setting !
Cancel [ESC] OK [ENT]
15
Remark:
If no external navigational data input or magnetic variation data is not included
in the external input data then:
1) HDT outputs magnetic bearing instead of true heading data.
2) The magnetic variation data in HDM would be 0 .
" "
" " " "
2. INSTALLATION & MOUNTING CONSIDERATIONS 2. INSTALLATION & MOUNTING CONSIDERATIONS
2.1 Fluxgate Unit
2.1.1 Outdoor installation
Keep the length of the cable in mind when selecting a mounting location.
It should be far away from their minimum 1 meters to prevent the
influence for iron and steel or other magnetic materials.
use not magnetic screws for fixed the unit.
Select the vertical way of positions for installation.
Please installed the Magnetic field sensor
Steel vessel, distortion
can be minimized.
Sensor
fluxgate sensor
on the top of wheelhouse
Don't install it in a room so that the magnetic
16
Cable to display unit
Fluxgate Sensor
Threaded tubes
(At least one meter length)
Rope
Fixed screw
MastRadar antenna
Wheelhouse
Fluxgate Sensor
2.1.2 Desktop mounting
To ensure the signal of sailing directions is accuracy, please choose a
location where vibration and shock are minimal.
only suitable for fiberglass or wooden vessel.
Installed in the surface of platform
17
2.1.3 Bulkhead mounting
The bulkhead installation can save the space.
The bulkhead cannot contain the steel with magnetic interference material.
Only suitable for fiberglass or wooden vessel.
Deck head
Bracket
Fluxgate Sensor
Top Mount
Bulkhead
Side Mount
Examples of bulkhead Mount
Bracket
Fluxgate Sensor
18
2.2 Display unit
Choose a location where vibration and shock are minimal.
Install the unit well away from subject to rain and water Splash. location
Locate the unit away from air conditioner vents.
Keep the unit out of direct sunlight because of heat that can build up inside
their cabinets.
Choose a well-ventilated location.
Choose a location where it can be easily operated.
Leave sufficient space around the units to permit access for maintenance.
See the outline drawing for recommended maintenance space.
19
2.2.1 Desktop, Overhead mounting
1. Fasten the hanger to the mounting location with four tapping screws
(supplied). See the outline drawing for mounting dimensions.
2. Screw the knobs into the display unit.
3. Set display unit to the hanger and tighten the knobs.
4. Run the ground wire between the ground terminal on the display unit and
the ship`s superstructure.
KEC-30 ELECTRONIC COMPASS
MENU
PWRKEC-30
ENT
ESC DIM
DISP
Desktop
KEC-30 ELECTRONIC COMPASS
MENU
PWRKEC-30
ENT
ESC DIM
DISP
Overhead
20
2.2.2 Flush mount
Flush mount
1. Fasten the display unit to the mounting location with tapping screws.
Connect host unit for power supply.
2. Prepare or buy installation accessories. The list below:
Name
2
M4X30
M4
M6X12
M6
4
4
2
2
Type Qty
Flush Mount Fixture
Wing Bolt
Wing Nut
Hex Bolt
Spring Washer
Manufacturing
3. Fasten the cosmetic panel to the display unit with hex bolts and spring
washers.
4. Screw the butterfly nut on the butterfly bolt.
5. Fix the display unit with the butterfly bolt and then tighten the butterfly nut.
Flush mount S
21
2.3 Wiring This section covers general wiring. For further details see the interconnection
diagram this manual.
In order to prevent the , wiring away from radio
antennas and antenna cable to prevent the transmission of radio signal
equipment.
The power source for the compass display shall be provided by the
independent fuse.
in
radio interference should
Magnetic field sensors connected
Power/data cable connection
6mm 1.5M
PIN 1
PIN 2
PIN 3
PIN 4
PIN 5
PIN 6
PIN 7
PIN 8
Connection diagram of KFG 25
Power/data cable connection diagram
22
NC
Power + Red
Power Black
Input + (White)
(Blue)
Shield
GreenRedYellowWhiteBlue
1 5
42
3
6
4
8
5
6
71
2
3
3. MAINTENANCE, TROUBLESHOOTING3. MAINTENANCE, TROUBLESHOOTING
WARNINGWARNING
ELECTRICAL SHOCK HAZARD
Do not open the equipment.
Only qualified personnel should work inside the equipment.
3.1 Preventive maintenanceRegular maintenance is important for good performance . A maintenance
program should be established and should include the following points.
Check connectors and ground terminal on the unit and
display unit for tightness.
Check ground terminal for rust. Clean or replace as necessary.
Check for water leakage in the
Clean or replace as necessary.
Remove dust and dirt from the display unit and unit with a
dry, soft cloth. For the LCD, wipe it carefully to prevent scratching, using
tissue paper and an LCD cleaner. To remove stubborn dirt, use an
LCD cleaner, wiping slowly with tissue paper so as to dissolve the dirt.
Change paper frequently so the dirt will not scratch the LCD. Do not
use chemical cleaners for cleaning they can remove paint and markings.
Note: do not use contain chemical cleaners clean, it might help to eliminate
paint and equipment will be marked.
fluxgate sensor
interconnection cable between fluxgate unit
and display unit.
fluxgate sensor
23
3.2 Troubleshooting
This section provides basic troubleshooting procedures which the user may
follow to restore normal operation.
Troubleshooting
Symptom
Cannot turn on the power
Power cable on the unitdisplay
Firmly connect the power cable
Power supply failure Check the power supply.
Blown fuse Have a qualified technician check the fuse.
Heading indication changes randomly when ship is at anchor or does not change when ship moves.
Sensor trouble Run the diagnostic test to determine cause.
Cause Remedy
Heading output from KEC-30 does not appear on extermal equipment.
Connection between KEC-30 and external equipment has loosened.
Firmly fasten the connector.
Display trouble Run the diagnostic test to determine the cause.
If large heading error occurs or heading indication is frequently interrupted,
contact your dealer for advice.
24
THE SPECIFICATIONS OF ELECTRONIC FLUXGATE COMPASS KEC-30
1 GENERAL
1.1 Heading Accuracy 1.0 (95%)
1.2 Heading Resolution 0.1
1.3 Follow-up 45 /s r ate-of-turn
25
2. POWER SUPPLY
2.1 Electrical 10.5 40VDC
Overcurrent, Overvoltage, Power transient and accidental reverse polarity
protection
3. (IEC61162-1)OUTPUT/INPUT
3.1 INPUT 1 NMEA0183: RMC, GSA
Input connector is TTL, RS-232, RS-422
Input data contains: RMC, GSA
3.2 OUTPUT 1 NMEA0183 : HDG, HDT, HDM
a) Output data includes the following three:
HDT: True heading
HDM: Magnetic heading
HDG: Magnetic heading & Magnetic variation value
Three types of outputs can select singly or output together, the optional
interval is 25ms, 100ms, 1,000ms(1s), The standard interval is 200ms,
three can output together .
The optional speed of output, the standard is 9600, the optional one is
9600, 19200 and 38400
b)
c)
Output connector is RS-232C NMEA 0183 (ver 2.0)
26
5. COMPLIANT WITH THE FOLLOWING STANDARDS
5.1 IEC60945 Edn 4.0 (IEC standard, environmental requirements)
5.2 IEC61162-1 Edn. 2.0 (IEC standard, digital interfaces part 1)
6. DISPLAY
6.1 4.5 diagonal 95(W) 63(H) mm LCD, 240 160 pixels
4 ENVIRONMENTAL CONDITIONS
4.1 Ambient Temperature
Display Unit -15 C to +55 C
unit -25 C t o + 70 C Fluxgate Sensor
4.2 Humidity 93% 3% to 40 C
4.3 Waterproofing
Display Unit IP 5
unit IP 7 Fluxgate Sensor
4.4 Vibration IEC 60945
Echo sounder
27
Fluxgate Sensor
Bracket
10
M s
tan
dar
d
Display
RadarPlotter
Ect.
INTERCONNECTION DIAGRAM
1
2
3
4
6
5
7
8
Input + White
Input (Blue)
Output + (Yellow)
Output (Green)
NC
GND
Power + (Red)
Power (Black)
POWER/DATA I/O
GND
1
2 3
4
5
6
Green
Red
Yellow
White
blue
Shield
28
1
2
3
4
6
5
7
8
1
2 3
4
5
6
To fluxgate Sensor Unit
CONNECTING CABLES
15
85.7
211.7
140.2
10.05
31
.5
168.9
175.0
211.7
13
0.710
4.6
KEC-30 ELECTRONIC COMPASS
29
DISPLAY UNIT SIZE
212mm
37mm
103mm
95mm
25.3mm
67.8mm
42.2mm
6.1mm
30
FLUXGATE SENSOR SIZE
31
104mm
4.5mm
104mm
97mm
31mm
C-BRACKET SIZE CHART