paragon electronic time controlsdms.hvacpartners.com/docs/1006/public/0e/timers_and...paragon...
Post on 25-Apr-2018
302 Views
Preview:
TRANSCRIPT
856
TIMERS
PARAGON ELECTRONIC TIME CONTROLS
EC4000 EC11 & EC11D EC7000 EC7005PC EC71 & EC71D
EC4000 SERIES 24-HOUR OR 7-DAYThe EC4000 Series are 24-hour, single-channel, electronic time controls that provide simple, inexpensive control of electri-cal loads with a time-of-day schedule. As a 24-hr. control, the same ON/OFF schedule is utilized each day. Saturday and/or Sunday, or any other day(s) of the week may be skipped. The skipped day(s) can be either load ON all day or load OFF all day, depending upon application. Sixteen events are available to provide programming versatility. An event defines an activity either load ON or load OFF. The EC4000 Series are available in either a NEMA 1 steel enclosure or a NEMA Type 3R non-metallic enclosure for indoor or outdoor use.
• 24-hr. programming with skip-a-day.• Four-day min. power outage carry-over without the use of a
battery.• 20 amp ballast switch rating on DPST model (UL only).• 16 ON or OFFs per day.• SPST, SPDT and DPST switching.• NEMA 1 or NEMA Type 3R enclosure.• Large display & simple programming with just 4 keys.
EC7000 SERIES 24-HOUR OR 7-DAYEC7000 Series are single-channel, electronic time controls that provide simple, inexpensive control of electrical loads with a time-of-day schedule. When schedules vary from day to day, the 7-day programming capability allows a different schedule for each day of the week. With 16 set points available, the EC7000 Series provides programming versatility. Models are also available to provide two individually programmable dura-tions of one to 59 seconds in addition to the maintained ON & OFF set points. This provides ideal control for bell or chime ringing in schools & factories. The EC7000 Series Controls are ideal for indoor & outdoor lighting, billboard & security lighting, school crossing lights, heating, ventilating, bell, chime & buzzer ringing, water heater & security system control.
• 24-hr. or 7-day programming - 7-day programming allows greater flexibility thus added energy savings by allowing loads to remain on only when needed.
• 4-day min. power outage carry-over without the use of batteries. Eliminates the need to replace batteries & the environmental concerns of battery disposal 16 set points 30 amp heavy duty relay-output allows switching most electrical loads without the use of contractors.
• To-the-minute programming with just four keys & a large easy to read display that uses visual prompts for ease of programming.
• SPST, SPDT, DPST switching designed for high immunity to electrical noise Momentary feature available.
• Recessed reset button• Available in NEMA Type 3R (EC7005) or NEMA 1
enclosures.NOTE:• Also available in 50 amp.• Contact your nearest branch for details and other available
models.
PART NO.RATING
PERPOLE
TYPE OF
OUTPUT
ENCLOSURETYPENEMA
SHIPPINGWGT.
LB KGEC4000 Series - 24-hour, single-channel, capacitor carry-over
EC4000/120V 20A SPDT 1 2 0.9EC4000PC/120V 20A SPDT 3R 2-1/2 1.1EC4000PC/120V-RT 20A SPDT 3R 2-1/2 1.1EC4000/208-277V 20A SPDT 1 2 0.9EC4000PC/208-277V PC/240V 30A SPDT 3R 2-1/2 1.1
EC4004/120V 30A SPST 1 2 0.9EC4004/120V-RT 30A SPST 1 2 0.9EC4004PC/120V 30A SPST 3R 2-1/2 1.1EC4004PC/120V-RT 30A SPST 3R 2-1/2 1.1EC4004/208-277V 30A SPST 1 2 0.9EC4004/208-277V-RT 30A SPST 1 2 0.9
EC4004PC/208-277V 30A SPST 3R 2-1/2 1.1EC4004PC/208-277V-RT 30A SPST 3R 2-1/2 1.1EC4005PC/120, 208-240V 30A DPST 3R 2-1/2 1.1EC4005PC/120, 208-240V-RT 30A DPST 3R 2-1/2 1.1
PART NO.RATING
PERPOLE
TYPE OF
OUTPUT
ENCLOSURETYPENEMA
SHIPPING WGT.
LB KGEC7000 Series - 24-hour and 7-day, single-channel, capacitor carry-over
EC7000/24V 20A SPDT 1 2 0.9EC7000/120V 20A SPDT 1 2 0.9EC7000PC/120V-RT 20A SPDT 3R 2 0.9EC7000/208-277V 20A SPDT 1 2 0.9EC7001PC/12VDC 10A SPDT 3R 1-1/2 0.7
EC7001/24V 20A SPDT 1 2 0.9EC7001/120V 20A SPDT 1 2 0.9EC7001/208-277V 20A SPDT 1 2 0.9EC7004/120V 30A SPST 1 2 0.9EC7004/208-277V 30A SPST 1 2 0.9EC7005PC/120V, 208-240V 30A DPST 3R 2 0.9
EC7005PC/277V 30A DPST 3R 2 0.9EC71/18S Series - 365-day, single channel
EC71/18S/120V 15A SPDT 1 2 0.9EC71D/18S/24V 15A SPDT DIN 1-1/8 0.5EC71D/18S/120V 15A SPDT DIN 1-1/8 0.5EC71D/18S/240V 10A SPDT DIN 1-1/8 0.5
EC1015P1178 P1183P1179 P1180 P1181 P1182
857
TIMERS
PARAGON 24-HOUR TIME SWITCHES
4000 SERIES
4010 SERIES
4210 SERIES
4000, 4010 AND 4210 SERIES1-1/2 Hour Minimum On or Off Time, 1 to 7 On/Off Operations Per Day
PART NO. SWITCHTYPE HP AC LINE
VOLTS
ENCLOSURE TYPENEMA
SHIPPING WGT.
LB KG.
4000 Series - Standard NEMA 1 indoor metal enclosure4001-00 SPST 1 120 1 2-1/2 1.14001-00-RT SPST 1 120 1 2-1/2 1.14001-00B SPST 1 120 - 2-1/2 1.14001-00M SPST 1 120 - 1-1/8 0.54002-71 SPST 1 208-277 1 2-1/2 1.14002-71B SPST 1 208-277 - 2-1/2 1.14003-00 DPST 1 120 1 2-1/2 1.14003-00-RT DPST 1 208-277 1 2-1/2 1.14003-00M DPST 1 208-277 - 1-1/8 0.54004-71 DPST 1 208-277 - 2-1/2 1.14004-71-RT DPST 1 208-277 - 2-1/2 1.14004-71B DPST 1 208-277 1 2-1/2 1.14004-71M DPST 1 208-277 - 1-1/8 0.54005-00B SPDT 1 120 - 2-1/2 1.1
With skip-a-day, allows schedule to be omitted on any day(s) without permanently disturbing preset schedule4003-00S DPST 1 120 1 2-1/2 1.14003-00SB DPST 1 120 - 2-1/2 1.14003-00SM DPST 1 120 - 1-1/8 0.54004-06S DPST - 24 1 2-1/2 1.14004-21S DPST 1 208-277 1 2-1/2 1.14005-00S SPDT 1 120 1 2-1/2 1.14005-00SB SPDT 1 120 - 2-1/2 1.14006-71S SPDT 1 208-277 1 2-1/2 1.14007-06S SPDT - 24 1 3-1/2 1.64007-06SB SPDT - 24 - 2 1.1
With skip-a-day and astro dial, adjusts for seasonal changes in sunrise and sunset times4003-00SZ32 DPST 1 120 1 3 1.44003-00SZ42 DPST 1 120 1 3 1.44004-71SZ32 DPST 1 208-277 1 3 1.44004-71SZ42 DPST 1 208-277 1 3 1.44005-00SZ32 SPDT 1 120 1 3 1.44005-00SZ42 SPDT 1 120 1 3 1.44006-71SZ32 SPDT 1 208-277 1 3 1.44006-71SZ42 SPDT 1 208-277 1 3 1.4
Leaves load on during day(s) scheduled to be skipped4008-20S DPST 1 208-240 1 2-1/2 1.1
4010 Series - Standard NEMA 3 indoor/outdoor metal or NEMA type 3R plastic enclosure4011-00 SPST 1 120 3 4-3/4 2.24011-00P SPST 1 120 3R 1-3/8 0.64011-00PC-RT SPST 1 120 3R 1-3/8 0.64013-00 DPST 1 120 3 4-3/4 2.24013-00P DPST 1 120 3R 1-3/8 0.64013-00PC-RT DPST 1 120 3R 1-3/8 0.64014-71 DPST 2 208-277 3 4-3/4 2.24014-71P DPST 2 208/277 3R 1-3/8 0.64014-71PC-RT DPST 2 208/277 3R 1-3/8 0.6
With skip-a-day, allows schedule to be omitted on any day(s) without permanently disturbing preset schedule4013-00S DPST 1 120 3 4-3/4 2.24014-71S DPST 1 208-277 3 4-3/4 2.2
With skip-a-day and astro dial, adjusts for seasonal changes in sunrise and sunset times4013-00SZ32 DPST 1 120 3 5-1/2 2.54013-00SZ42 DPST 1 120 3 5-1/2 2.5
4000 & 4000S SERIES 24-HOUR
The 4000 series has a 24-hour dial with 2 to 14 replaceable trippers for 1 to 7 “On” and “Off” operations per day.
The 4000-S series is the same as the 4000 series but with “Skip-A-Day” fea-ture to allow skipping operations on any day or days of the week without disturb-ing the preset schedule.
• 1/2 hour min. On or Off time; 22-1/2 hour max. On or Off time.
• Manual On/Off lever transfers switch operation without disturbing preset schedule.
• Switch slider bar assures positive switching.
• Heavy duty terminals accommodate up to AWG #8 wire.
• NEMA type 1 indoor case with combination 1/2-3/4 in. knockouts in bottom and sides; hasp for padlock or seal.
P1203
P1204
P1205
858
TIMERS
PARAGON 7-DAY TIME SWITCHES7000 SERIES
7-day calendar permits different “On/Off” schedules on different days of the week. Maximum of 4 On/Off operations per day and 28 per week.
• 3 hour min. On or Off time per day; 21 hour max. On or Off time per day.
• Independent 4-pole design allows for SPST, DPST or SPDT switching.
• Manual overrride lever temporarily reverses switch operation without permanently disturbing preset schedule.
• Switch slider bar assures positive switching
• Heavy duty industrial type synchronous motor.
• Heavy duty terminals accommodate up to AWG #8 wire.
• Standard NEMA 1 indoor metal enclosure side hinged with combination 1/2-3/4 in. knockouts in bottom and side. Hasp for padlock or seal.
7210 SERIES
7-day calendar permits different “On/Off” schedules on different days of the week. Maximum of 4 On/Off operations per day and 28 per week.
• 3 hour min. On or Off time per day; 21 hour max. On or Off time per day.
• Independent 4-pole design allows for SPST, DPST or SPDT switching.
• Manual overrride lever temporarily reverses switch operation without permanently disturbing preset schedule.
• Switch slider bar assures positive switching
• Heavy duty industrial type synchronous motor.
• Heavy duty terminals accommodate up to AWG #8 wire.
• Standard NEMA 3 indoor/outdoor metal enclosure side hinged with combination 1/2-3/4 in. knockouts in bottom and sides. Hasp for padlock or seal.
• Spring wound carry-over to take over during power outages, keeping control running up to 10 hours. Only two hour wind up required for each hour of power outage.
P1177
7000 and 7210 SERIES
4-Pole, 3 Hour Minimum On or Off Time, 4 On/Off Operations per Day, 28 per Week
*Not UL or CSA listed.Hp rating one pole only.Furnished with 7 sets of on/off trippers.Switch rating per pole = 40 amp. Hertz = 60.
PART NO.SWITCH
TYPESWITCH RATING PER POLE
AC LINE60 HZ
ENC.TYPENEMA
SHIPPING WGT.
AMP AMP T VA HP VOLTS LB KG.7000 Series7007-00 4PST-4 NO 40 40 690 - 120 1 6-1/2 2.9
* 7007-06 4PST-4 NO 40 - 345 - 24 1 6-1/2 2.97007-71 4PST-4 NO 40 40 690 - 208-277 1 6-1/2 2.97008-00 2 NO-2 NC 40 - 690 1 120 1 6-1/2 2.97008-00B 2 NO-2 NC 40 - 690 1 120 - 6-1/2 2.9
* 7008-06 2 NO-2 NC 40 - 345 - 24 1 6-1/2 2.97008-71 2 NO-2 NC 40 - 690 1 208-277 1 6-1/2 2.9
7210 Series - With spring wound carry-over7217-00 4PST-4 NO 40 40 690 - 120 3 10 4.57217-20 4PST-4 NO 40 40 690 - 208-240 3 10 4.5
859
TIMERS
GRASSLIN GM MULTIVOLT SERIES (24-Hour, 7-Day)
• 120, 208/240 or 277 VAC.
• 30 A, 2 HP @ 240 V switch.
• Indoor or outdoor enclosure.
• Captive trippers with interval of 15 minutes on 24-hour model.
• Easy to set clock face timer.
• Optional clear cover allows viewing timer clock face without opening cover.
P4176
Enclosure Options, Substitute the Following for “X”:“I” = NEMA 1 Indoor Enclosure, “IC” = NEMA 1 Indoor Enclosure with Clear Cover,
“O” = NEMA 3R Outdoor Enclosure, “OC” = NEMA 3R Outdoor Enclosure with Clear Cover,“IM” = NEMA 1 Indoor Metal Enclosure, “M” = Mechanism Only — No Enclosure
PART NUMBER TIMER VOLTAGE SWITCH AMPS MODEL CODE TIMER VOLTAGE SWITCH AMPS24-Hour 7-Day
GM1 ST-“X”-MV 120, 208/240, 277 V SPDT 30 GM1 SW-“X”-MV 120, 208/240, 277 V SPDT 30GMD ST-”X”-MV 120, 208/240, 277 V DPDT 30 GMD SW-“X”-MV 120, 208/240, 277 V DPDT 30
24-Hour, Battery Backup 7-Day, Battery BackupGM1 QT-“X”-MV 120, 208/240, 277 V SPDT 30 GM1 QS-“X”-MV 120, 208/240, 277 V SPDT 30GMD QT-“X”-MV 120, 208/240, 277 V DPDT 30 GMD QS-“X”-MV 120, 208/240, 277 V DPDT 30
LISTED8827
File #E83486
CROSS REFERENCE
GM MULTI-VOLT SERIESIntermatic Tork Paragon
GRASSLINGM1 ST-I-MV =
T101T101(B)
T102T102(B)
T105T185T1905T1906
1101110280018004
P1014001-004002-714005-00
1015-00RS
GRASSLINGM1 ST-O-MV =
T101PT101R
T101(B)T102PT102R
T102(B)T106R
T1905RT1906R
1101-N1102-N8001-N8004-N
P101P4011-00(P)42011-0024011-20
GRASSLINGMD ST-I-MV =
T101T102T103T104T105
1101110211031104
P103P104
4003-004004-71
1015-00RS
GRASSLINGMD ST-O-MV
T103T103PT103RT104
T104PT104R
1101-N1102-N1103-N1104-N8002N8042N
P103PP104P
4011-00(P)4013-004014-71
42013-0042013-20
GMX SERIES
GRASSLINGMX ST-I-120 =
T101T101(B)T1906
11018001
P1011015-00RS
GRASSLINGMX ST-O-120 =
T101PT101(B)T1905-R
1101-N8001-N
P101P42011-00
860
TIMERS
GRASSLIN GMX SERIES (24-Hour, 7-Day)
GRASSLIN KM2 IN-WALL TIMER (24-Hour, 7-Day)
• 21 A, 2 HP @ 240 V switch.
• Indoor or outdoor enclosure.
• Captive trippers with interval of 15 minutes on 24-hour model.
• Easy to set clock face timer.
• Optional clear cover allows viewing timer clock face without opening cover.
P4177
Enclosure Options, Substitute the Following for “X”:“I” = NEMA 1 Indoor Enclosure, “IC” = NEMA 1 Indoor Enclosure with Clear Cover,
“O” = NEMA 3R Outdoor Enclosure, “OC” = NEMA 3R Outdoor Enclosure with Clear Cover,“IM” = NEMA 1 Indoor Metal Enclosure
PART NUMBER TIMER VOLTAGE SWITCH AMPS PART NUMBER TIMER VOLTAGE SWITCH AMPS24-Hour 7-Day
GMX ST-“X”-120 120, 60 Hz SPDT 21 GMX SW-“X”-120 120, 60 Hz SPDT 21GMX ST-“x”-240 208/240 v, 60 Hz SPDT 21 GMX SW-“X”-240 208/240 V, 60 Hz SPDT 21
GMX ST-“X”-24 24 V, 60 Hz SPDT 21 GMX SW-“X”-24 24 V, 60 Hz SPDT 21GMX ST-“X”-277 277 V, 60 Hz SPDT 21 GMX SW-“X”-277 277 V, 60 Hz SPDT 21
24-Hour, Battery Backup 7-Day Battery BackupGMX QT-“X”-120 120, 50/60 Hz SPDT 21 GMX QW-“X”-120 120, 50/60 Hz SPDT 21GMX QT-“X”-240 208/240 V, 50/60 Hz SPDT 21 GMX QW-“X”-240 208/240 V, 50/60 Hz SPDT 21GMX QT-“X”-24 24 V, 50/60 Hz SPDT 21 GMX QW-“X”-24 24 V, 50/60 Hz SPDT 21
LISTED8827
File #E83486
P4178 LISTED8827
File #E83486
PART NUMBER
WALLPLATE CONFIGURATION SWITCH24-HOUR 7-DAY
KM2 ST-1G KM2 SW-1G 1 Gang SPST
KM2 STu-1G KM2 SWu-1G 1 Gang, 3 Way SPDT
KM2 ST-2G KM2 SW-2G 2 Gang, Toggle SPST
KM2 STu-2G — 2 Gang, Toggle, 3 Way SPDT
KM2 ST-3G KM2 SW-3G 3 Gang, Toggle SPST
KM2 ST-4G KM2 SW-4G 4 Gang, Toggle SPST
KM2 ST-2D KM2 SW-2D 2 Gang, Decorator SPST
KM2 ST-3D KM2 Sw-3D 3 Gang, Decorator SPST
KM2 ST-2R KM2 SW-2R 2 Gang, Receptacle SPST
KM2 STST-2G KM2 SWSW-2G 2 Gang, Dual Timers (2) SPST
• Captive trippers with 20-minute switching interval (2-1/3 hour for 7-day).
• SPST 20 A, 1 Hp @ 120 V switch.
• Replaces standard wall switches.
• Reliable synchronous timer motor.
861
TIMERS
GRASSLIN MIL 72 SERIES (24-Hour, 7-Day)
GRASSLIN GM digi SERIES (24-Hour, 7-Day)
**Quartz units also operate on DC voltages down to 12 VDC.
Complete Part Number = MIL 72A or E Followed by Suffix Code and Voltage.Example: MIL 72A STuZ-24
SYNCHRONOUSQUARTZ 7-DAYCARRY-OVER** INPUT
VOLTAGESWITCH RATING
240 V RES.MINIMUM
ON/OFF TIME
EVENTON/OFF
TIMEWithout Override With 3-Way Override With 3-Way OverrideMIL 72A — Surface MountMIL 72E — Flush Mount 24-HOUR TIME CONTROL
STuZ-24 STuZH-24 QTuZH-24 24 VAC SPDT 21A 15 min. ON 1/4 hr.STuZ-120 STuZH-120 QTuZH-120 120 VAC SPDT 21A 15 min. ON 1/4 hr.STuZ-240 STuZH-240
STuZH-277QTuZH-240 208/240 VAC
277 VACSPDT 21ASPDT 21A
15 min.15 min.
ON 1/4 hr.ON 1/4 hr.
MIL 72A — Surface MountMIL 72E — Flush Mount 7-DAY TIME CONTROL
SWuZ-24 SW7ZH-24 QWuZH-24 24 VAC SPDT 21A 2 hr. ON 2 hr.SWuZ-120 SWuZH-120 QWuZH-120 120 VAC SPDT 21A 2 hr. ON 2 hr.SWuZ-240 SWuZH-240
SWuZH-277QWuZH-240 208/240 VAC
277 VACSPDT 21ASPDT 21A
2 hr.2 hr.
ON 2 hr.ON 2 hr.
• Synchronous drive or quartz drive with battery backup.
• 21 A SPDT switch.
• Captive trippers with interval as low as 15 minutes.
• With or without 3-way override.
• Real clock face.
P4179
LISTED
IN OPTIONAL ENCLOSURES
CSA FILE: LR52379
UL FILE: E83486
• 30 A, 2 HP @ 240 V switch.
• Indoor or outdoor enclosure.
• Rechargeable battery backup with 1 week or more carryover.
• Optional clear cover allows viewing timer clock face without opening cover.
• GM digi 42 models have holiday program and automatic daylight time changeover.
P4180
Enclosure Options, Substitute the Following for “X”:“I” = NEMA 1 Indoor Enclosure, “IC” = NEMA 1 Indoor Enclosure with Clear Cover,
“O” = NEMA 3R Outdoor Enclosure, “OC” = NEMA 3R Outdoor Enclosure with Clear Cover,“IM” = NEMA 1 Indoor Metal Enclosure, “M” = Mechanism Only — No Enclosure
PART NUMBER TIMER VOLTAGE PROG. SWITCH AMPS MODEL CODE TIMER VOLTAGE PROG. SWITCH AMPSOne Channel, 24-Hour/7-DayGM1 digi 12-“X”-120 120 V, 50/60 Hz 12 SPDT 30 GMD digi 20-“X”-120 120 V, 50/60 Hz 20 DPDT 30GM1 digi 12-“X”-240 208/240 V, 50/60 Hz 12 SPDT 30 GMD digi 20-“X”-240 208/240 V, 50/60 Hz 20 DPDT 30
GMD digi 12-“X”-120
120 V, 50/60 Hz 12 DPDT 30 GMD digi 20-“X”-277 277 V, 50/60 Hz 20 DPDT 30
GMD digi 12-“X”-240
208/240 V, 50/60 Hz 12 DPDT 30 GM1 digi 42-“X”-120† 120 V, 50/60 Hz 42 SPDT 30
GM1 digi 20-“X”-120 120 V, 50/60 Hz 20 SPDT 30 GM1 digi 42-“X”-240† 208/240 V, 50/60 Hz 42 SPDT 30GM1 digi 20-“X”-240 208/240 v, 50/60 Hz 20 SPDT 30 GMD digi 42-“X”-120† 120 V, 50/60 Hz 42 DPDT 30GM1 digi 20-“X”-277 277 V, 50/60 Hz 20 SPDT 30 GMD digi 42-“X”-240† 208/240 V, 50/60 Hz 42 DPDT 30
LISTED8827
File #E83486
C.E.C. CERTIFIEDTITLE 24, PART 6
ON ALL MODELS MARKED WITH “†”
862
TIMERS
GRASSLIN GMX digi SERIES (24-Hour, 7-Day)
GRASSLIN digi 42/2 (24-Hour, 7-Day)
• 16 A @240 V switch.
• Indoor or outdoor enclosure.
• Rechargeable battery backup with 1 week or more carryover.
• Optional clear cover allows viewing timer clock face without opening cover.
P4181
Enclosure Options, Substitute the Following for “X”:“I” = NEMA 1 Indoor Enclosure, “IC” = NEMA 1 Indoor Enclosure with Clear Cover,
“O” = NEMA 3R Outdoor Enclosure, “OC” = NEMA 3R Outdoor Enclosure with Clear Cover, “IM” = NEMA 1 Indoor Metal Enclosure
PART NUMBER TIMER VOLTAGE PROG. SWITCH AMPS PART NUMBER TIMER VOLTAGE PROG. SWITCH AMPSNOTE: 6 V and 12 VDC Models AvailableGMX digi 12-“X”-120 120 V, 50/60 Hz 12 SPDT 16 Two ChannelGMX digi 20-“X”-120 120 V, 50/60 Hz 20 SPDT 16 GMX2 digi 42-“X”-120† 120 V, 50/60 Hz 42 (2) SPDT 16
GMX digi 20-“X”-240 208/240 V, 50/60 Hz 20 SPDT 16 GMX2 digi 42-“X”-240† 208/240 V, 50/60 Hz 42 (2) SPDT 16GMX digi 20-“X”-24 24 V, 50/60 Hz 20 SPDT 16 GMX2 digi 42-“X”-24† 24 V, 50/60 Hz 42 (2) SPDT 16GMX digi 20-“X”-277 277 V, 50/60 Hz 20 SPDT 16GMX digi 42-“X”-120 120 V, 50/60 Hz† 42 SPDT 16GMX digi 42-“X”-240 208/240 V, 50/60 Hz† 42 SPDT 16GMX digi 42-“x”-24 24 V, 50/60 Hz† 42 SPDT 16
LISTED8827
File #E83486
C.E.C. CERTIFIEDTITLE 24, PART 6
ON ALL MODELS MARKED WITH “†”
• Two channel or double pole switching.
• Automatic daylight time changeover.
• 8th day HOLIDAY program.
• 16 A, SPDT switching.
P4182
For DIN rail mounting, order: MB-DIN Rail Mounting Base.
PART NUMBER TIMER VOLTAGE MOUNTING*SETPOINT
PROGRAMSMAXIMUM WEEKLY
ON/OFF EVENTSRELAY OUTPUT
GENERAL PURPOSE RATING
Digi 42/2-120†† 120 V, 50/60 Hz Flush or Surface 42 294 (2) SPDT, 16 A, 240 VACDigi 42/2-240† 240 V, 50/60 Hz Flush or Surface 42 294 (2) SPDT, 16 A, 250 VACDigi 42/2-24† 24 V, 50/60 Hz Flush or Surface 42 294 (2) SPDT, 16 A, 250 VAC
C.E.C. CERTIFIEDTITLE 24, PART 6
ON ALL MODELS MARKED WITH “†”
UL FILE: E83486
863
TIMERS
GRASSLIN digi 20, digi 42 SERIES (24-Hour, 7-Day)
GRASSLIN talento 400 & 800 SERIES(24-Hour, 7-Day, 365-Day Electronic Time Controls)
• Automatic Daylight Time changeover with Digi 42
• Holiday program with Digi 42.
• Rechargeable battery backup with 1 week or more carryover.
• 16 amp, SPDT switching.
P4183
For DIN rail mounting, order: MB-DIN Rail Mounting Base.
PART NUMBER TIMER VOLTAGE MOUNTING*SETPOINT
PROGRAMSMAXIMUM WEEKLY
ON/OFF EVENTSRELAY OUTPUT
RESISTIVE RATINGDigi 20A — 120 120 V, 50/60 Hz Surface or DIN Rail 20 140 SPDT, 16 A, 250 VDigi 20A — 240 208/240 V, 50/60 Hz Surface or DIN Rail 20 140 SPDT, 15 A, 250 VDigi 20A — 24 24 V, 50/60 Hz Surface or DIN Rail 20 140 SPDT, 16 A, 250 VDigi 20A — 277 277 V, 50/60 Hz Surface or DIn Rail 20 140 SPDT, 16 A, 250 VDigi 42A — 120† 120 V, 50/60 Hz Surface or DIN Rail 42 294 SPDT, 16 A, 250 VDigi 42A — 240† 208/240 V, 50/60 Hz Surface or DIN Rail 42 294 SPDT, 16 A, 250 VDigi 42A — 24† 24 V, 50/60 Hz Surface or DIn Rail 42 294 SPDT, 16 A, 250 VDigi 20E — 120 120 V, 50/60 Hz Flush Panel 20 140 SPDT, 16 A, 250 VDigi 20E — 240 208/240 V, 50/60 Hz Flush Panel 20 140 SDPT, 16 A, 250 VDigi 20E — 24 24 V, 50/60 Hz Flush Panel 20 140 SPDT, 16 A, 250 VDigi 20E — 277 277 V, 50/60 Hz Flush Panel 20 140 SPDT, 16 A, 250 VDigi 42E — 120† 120 V, 50/60 Hz Flush Panel 42 294 SDPT, 15 A, 250 VDigi 42E — 240† 208/240 V, 50/60 Hz Flush Panel 42 294 SDPT, 16 A, 250 VDigi 42E — 24† 24 V, 50/60 Hz Flush Panel 42 294 SPDT, 16 A, 250 V
C.E.C. CERTIFIEDTITLE 24, PART 6
ON ALL MODELS MARKED WITH “†” UL FILE: E83486P4184
Digi 42A
Digi 20E
• 1, 2 and 4 channels.
• Automatic leap year and daylight savings adjustment.
• “Pulse” and “Cycle” programming.
• Lithium battery backup.
• Non-volatile program memory.
talento 894
talento 471LISTED
IN OPTIONAL ENCLOSURES
CYCLE PROGRAMMING
P4185
864
TIMERS
GRASSLIN FM/1 SERIES (24-Hour, 7-Day)
GRASSLIN KM2 SERIES (24-Hour, 7-Day)
• Authentic clock face.
• 21 A SPDT switch.
• Captive Trippers.
P4186
CSA FILE: LR52379 UL FILE: E83486
†For 3-way override switch: Add “H”.
NOTES:1. Available with 24 V, 120 V, 240 V, 277 VAC input.2. Quartz also available with 12 V, 30 V, 60 V, or 120 VDC input.
PART NUMBERSWITCH
PROGRAMCARRY-OVER
PROGRAMON/OFF EVERY
MINIMUMON/OFF TIME
SWITCH OUTPUTType Rating
FM/1 StuZ (synchronous) 24 hr. No 15 minutes 15 minutes SPDT 21 A Res.FM/1 SWuZ (synchronous) 7 day No 2 hours 2 hours SPDT 21 A Res.FM/1 QtuZ (quartz) 24 hr. 7 day 15 minutes 15 minutes SPDT 21 A Res.FM/1 QWuZ (quartz) 7 day 7 day 2 hours 2 hours SPDT 21 A Res.
• Very small and compact, fits anywhere.
• On/Auto/Off manual switch standard.
• Captive trippers for easy programming.
P4187
CSA FILE: LR52379 UL FILE: E83486
PART NUMBEROPERATING FEATURES SWITCH OUTPUT
Switch ProgramProgram On/Off
EveryMinimum On/Off
TimeType Rating
KM2 STuH 24 hr. 20 minutes 20 minutes SPDT 21 A Res.KM2 SWuH 7 day 2 hr., 20 minutes 2 hr., 20 minutes SPDT 21 A Res.
865
TIMERS
GRASSLIN FM/1 digi 20 (24 Hour, 7-Day)
GRASSLIN FM/1 digi 42 (24 Hour, 7-Day)
• 20 programs, up to 140 events per week.
• Easy to program with large keys.
• 16 Amp @ 277 V SPDT switching.
• Capacitor backup with 5-day carryover.
• Manual override.
P4188
UL FILE: E83486
• Automatic Spring/Fall Daylight Time changeover.
• 42 programs, up to 294 events per week.
• Holiday programming.
• 16 Amp @ 277 V SPDT switching.
• Rechargeable battery backup with carryover of over 2 weeks.
FM/1 digi 42 Also Available for 12 VDC input, 24 V Models are AC/DC
PART NUMBER Input VoltageSwitch
ProgramPrograms
Max. WeeklyOn/Off Events
HolidayProgram
ReserveCarryover
Relay Output
FM/1 digi 20-120 120 V, 50/60 Hz 24 hr./7 day 20 140 No 1 week SPDT 16 AFM/1 digi 20-240 240 V, 50/60 Hz 24 hr./7 day 20 140 No 1 week SPDT 16 AFM/1 digi 20-24 24 V, 50/60 Hz 24 hr./7 day 20 140 No 1 week SPDT 16 AFM/1 digi 20-277 277 V, 50/60 Hz 24 hr./7 day 20 140 No 1 week SPDT 16 A
FM/1 digi 42-120† 120 V, 50/60 Hz 24 hr./7 day 42 294 Yes 2 weeks SPDT 16 AFM/1 digi 42-240† 240 V, 50/60 Hz 24 hr./7 day 42 294 Yes 2 weeks SPDT 16 AFM/1 digi 42-24 24 V, 50/60 Hz 24 hr./7 day 42 294 Yes 2 weeks SPDT 16 A
C.E.C. CERTIFIEDTITLE 24, PART 6
ON ALL MODELS MARKED WITH “†”
866
TIMERS
GRASSLIN KLT SERIES INTERVAL TIMERS
GRASSLIN ET 616 ELECTRONIC INTERVAL TIMER
SPRING WOUND INTERVAL/COUNTDOWN TIME SWITCH
• Timing ranges from 5 minutes to 12 hours.
• SPST 20 A, 2 HP switch.
• Decorator style dial plate fits both standard and decorator wallplates.
• Aluminum wallplate available.
• Fits in single or multigang wallboxes.
• May be flush panel mounted.
• Normally closed version (15 and 30 min. only)
P4189
P4190
LISTED
FILE #E83486
Example: KLT-30M-W — Add “-W” to above for white knob and plate.Example: KLT-30MH-A — Add “-A” to above for aluminum plate and plastic knob.
TIME CYCLEPART NO.
NO-HOLD MODELS WITHIVORY KNOB & PLATE
HOLD MODELS WITHIVORY KNOB & PLATE
0-5 Minutes KLT-5M KLT-5MH0-15 Minutes KLT-15M KLT-15MH
0-15 Minutes (Normally Closed) KLT-15MC —0-30 Minutes KLT-30M KLT-30MH
0-30 Minutes (Normally Closed) KLT-30MC —0-60 Minutes KLT-60M KLT-60MH
0-2 Hours KLT-2H KLT-2HH0-4 Hours KLT-4H KLT-4HH0-6 Hours KLT-6H KLT-6HH0-12 Hours KLT-12H KLT-12HH
• Operates on 120 V or 277 VAC — No neutral wire required.
• Mounts in standard wallbox.
• Single button On/Off operation.
• Backlighted LCD display.
• Preset time adjustments; 5, 15, 30, 60 minutes, 3, 6, 9, 12 hours.
• Switch holds position during a power failure (on or off), restarts at preset time when power is restored.
• UL and cUL listed.
P4191
PART NUMBER VOLTAGE TIMING INTERVAL SWITCH RATING
ET616120 or 277 VAC,
50/60 Hz5, 15, 30, 60 Min.
3, 6, 9, 12 Hr.
1000 W (Tung.) @ 120 V800 W (Bal.) @ 120 V
1500W (Tung.) @ 277 V1200W (Bal.) @ 277 V
867
REFRIGERATION DEFROST CONTROLS
PARAGON COMMERCIAL REFRIGERATION DEFROST CONTROLS8040 SERIES
• Frequency of defrost initiation is adjustable from 1-6 cycles per day. Min of 4 hours between successive operations.
• Duration of defrost cycle is adjustable from 4-110 minutes in 2 minute increments.
• Accuracy of defrost duration ± 2 minutes.
• Choice of 4 contact arrangements for electric heat, hot gas or compressor shutdown defrost.
• Positive switch action slider bar.
• Heavy duty synchronous motor.
• Heavy steel enclosure. Grey finish. Knockouts on bottom, back and sides. Hasp and staple for padlock. Available on bracket for sub-panel mounting.
8140 SERIES
• Frequency of defrost is 1-6 cycles per day. Min of 4 hours between successive defrost cycles.
• Adjustable back-up defrost termination from 4-110 minutes in 2 minute increments.
• Control works with an external temperature or pressure sensor.
• Choice of 3 contact arrangements for electric heat, compressor shutdown defrost or hot gas defrost.
• Positive switch action slider bar.
• Heavy duty synchronous industrial type motor.
• Heavy steel enclosure. Grey finish. Knockouts on bottom, back and sides. Hasp and staple for padlock. Available on bracket for sub-panel mounting.
P1170
8040 & 8140 SERIES
8040 SERIES
Time Initiated, Time Terminated, 40 Amp
NEMA 1 indoor metal enclosure.
8140 SERIES
Time Initiated, Remote Temperature or Pressure Terminated, 40 Amp
NEMA 1 indoor metal enclosure.
PART NO.AC LINE
60 HZVOLTS
SWITCH ARRANGEMENTCONTACTS ADJ. LENGTH
OF DEFROST2-4 1-3 3-N
8041-00 120 Closed Open Closed 4-110 Min.8041-20 208-240 Closed Open Closed 4-110 Min.8045-00 120 Closed Open None 4-110 Min.8041-20 208-240 Closed Open None 4-110 Min.8047-00 120 Open Open Closed 4-110 Min.8047-20 208-240 Open Open Closed 4-110 Min.
PART NO.AC LINE
60 HZVOLTS
NORMAL POSITION OF CONTACTSDURING REFRIGERATION CYCLECONTACT
N-3CONTACT
1-3CONTACT
2-4NEMA 1 indoor metal enclosure
8141-00 120 Closed Open Closed8141-20 208-240 Closed Open Closed8143-00 120 Open Closed Open8143-20 208-240 Open Closed Open8145-00 120 None Open Closed8145-20 208-240 None Open Closed
868
REFRIGERATION DEFROST CONTROLS
PARAGON COMMERCIAL REFRIGERATION DEFROST CONTROLS8240 SERIES
• Frequency of defrost is 1-6 cycles per day. Min. of 4 hours between successive defrost cycles.
• Adjustable back-up defrost termination from 4-110 minutes in 2 minute increments.
• Choice of 3 contact arrangements for electric heat, compressor shutdown defrost or hot gas defrost.
• Positive switch action slider bar.
• Heavy duty synchronous industrial type motor.
• Heavy steel enclosure. Grey finish. Knockouts on top. Available on bracket for sub-panel mounting. 8240 SERIES
P1202
8240 SERIES
Time Initiated, Pressure Terminated, 40 Amp
NEMA 1 indoor metal enclosure.
PART NO.UPC NO.
79046
AC LINE60 HZVOLTS
NORMAL POSITION OF CONTACTSDURING REFRIGERATION CYCLE
CONTACTN-3
CONTACT1-3
CONTACT2-4
8245-00 00580 120 Closed Open None8245-20 00590 208-240 Closed Open None8247-20 00610 208-240 Open Open Closed
869
REFRIGERATION DEFROST CONTROLS/ACCESSORIES
PARAGON ACCESSORIESDIAL TRIPPERS, PINS AND BATTERIES
*See Bulletin #3010.
PARTNUMBER
USE WITH SERIES QUANTITY PER SET
X277240004010
4210 4701747217
1 ON, 1 OFF
X34954000-S
4000-SZ4210-S
4210-SZ47017-S
47017-SZ6 cutout pins
X35968025þ8040*
8140*8240*
5 trippers
X42964000-S4210-S
47017-S47217-S
Cutout index tripper (ON)
X4299 7000 7210 1 ON, 1 OFFX7248 RM* 12X8348 4008-S 1 ON, 1 OFFX9242 P100 1 ON, 1 OFFX9246 P100-S Cutout pins (6)X9249 4008-S Cutout Index tripper (OFF)X9250 P100-S Cutout Index tripper (ON)
X2772 X3495 X3596 X4296 X4299 X8348 X9242 X9246 X9249 X9250
Brackets For Panel Mounting
*Must be used with 4010PC.
PARTNUMBER
USE WITH SERIES NOTESSHIPPING WGT.LB KG
A454-W (X2626) 8025 8040 8140 — 1-1/2 0.7
A536 (X4105)
40004000-S4000-SZ4010
4010-S4010-SZ41010EC4000
P100EC7000
not for carry-over models 1-1/2 0.7
A537-W (X3967)6231015
42010 1015-40TSnot for carry-over models 1-1/2 0.7
A569 (X5815)4701747217
70007010
7210 may be used with carry-over models 1-1/2 0.7
D874-99 IntermaticAdapter Bracket
40004000-S4010
4010-SP100
EC4000EC7000 not for carry-over models 3 oz. 0.1
A1408-99*EC4000EC4004
4010PCEC7000
EC7001EC7004
— 3 oz. 0.1
A454 (X2626) A569 (X5815) A536 (X4105) D874-99 A537 (X3967) A1408-99
P1184 P1185 P1186 P1187 P1188 P1189 P1190 P1191
P1192 P1193 P1194 P1195 P1196 P1197
870
REFRIGERATION DEFROST CONTROLS/ACCESSORIES
GRASSLIN FROSTKINGDTMV — 120/240 VOLTS — The Only One To Stock!!
SPECIFICATIONS• Switch Rating:
30 A Resistive @ 208-250 VAC2 HP @ 208-250 VAC; 1 HP @ 125 VAC690 VA Pilot Duty @ 125-250 VAC“F” Terminal:10 A Resistive @ 208-250 VAC1 HP @ 208-250 VAC; 1/2 HP @ 125 VAC(Terminal 1-3 rating reduced to 20 A when “F” terminal used.)
• Wiring Connections: Screw clamp terminals accommodate up to two #8 AWG wires.• Environmental Ratings:
Operating Temperature Range: –40° F to 131° F (–40° C to 55° C)Operating Humidity: 0 to 95% Non-Condensing
• Dimensions: 10 in. x 6.5 in. x 3.75 in. Deep• Shipping Weight: 2 lbs.
P4192
LISTED8827
FILE #E83486
GRASSLIN DTMV SERIESApplicationThe DTMV is used in compressor shutdown (air defrost) applications where the space temperature is above freezing (above 32° F, 0° C). It may also be used on electric or hot gas defrost applications where the defrost is terminated when the coil is frost free, as sensed by a temperature or pressure switch, even though the programmed defrost termi-nation time has not been reached.
ORDERING DATATime Initiated, Remote Temperature, Pressure, or Time TerminatedAdd “-M” for Mechanism Only. Add “-P” for Panel Mount (Less Enclosure)
Standard models are also available with 50 Hz input in 208/240 V. Add “-C” to model for clear cover.
P/N VOLTAGE TIMER BATTERYBACK-UP
DEFROST FREQUENCYNO./DAY
DEFROSTDURATION
MINIMUM DURATIONINTERVAL
StandardDTMV — 120/240 120 V, 208/240 V, 60 Hz Synchronous No 1 to 24 15-180 min. 15 minutesQuartz Battery BackupDTQMV 120 V, 208/240 V, 50/60 Hz Quartz 14 Day 1 to 24 15-180 min. 15 minutesElectronicDT 140 digi 20-120 120 V, 50/60 Hz Electronic 7 Day 1 to 8 1-180 min. 1 minuteDT 140 digi 20-240 208/240 V, 50/60 Hz Electronic 7 Day 1 to 8 1-180 min. 1 minute
• Universal Replacement*4 models replace 30 competitive modelsMounts in existing enclosuresStandard wiring
• Defrost times settable on quarter hour• NEMA 3R outdoor enclosure• 30 Amp, 2 HP Rating• Electromechanical or electronic• Optional clear cover allows viewing timer clock face without opening cover• LED indication of defrost• Terminal identification and wiring the same as existing defrost timers; nothing new to lea• Frequency of defrost initiation adjustable from 1 to 24 cycles per day, minimum 15 minut
between defrosts• Duration of defrost adjustable from 15 minutes to several hours in 15 minute increments
(1 min. for electronic models)• Selectable electric/compressor shutdown - or - hot gas defrost modes• Captive trippers in 15 minute increments ease setting of defrost times, ends not enough
trippers• Quartz drive timer available with battery backup to maintain time of day on clock over
7 days without power.• Electronic timer available with 7 day programming, 1 minute resolution and battery back• U.L. Listed (USA and Canada)
SPECIFIER’S GUIDEFurnish and install a Grasslin DTMV defrost control which is field adjustable for 120 V or 240 V operation and shall have defrost initi-ation times settable to the quarter hour via captive trippers at 15 minute intervals. The defrost timer shall be housed in a NEMA 3R indoor/outdoor plastic enclosure. The relay output will be rated for 30 A Resistive, 2 Hp @ 250 VAC. Defrost termination to be by time (and by a remote temperature or pressure switch).
UNIVERSAL REPLACEMENTTime Initiated, Remote Temperature, Pressure orTime Terminated
PARAGON PRECISION
GRASSLINDTMV =
8141-00 6141-008143-00 6143-008145-00 6145-008041-00 6041-008043-00 6043-008045-00 6045-008046-008047-00 6047-008141-20 6141-208143-20 6143-208145-20 6145-208041-20 6041-208043-20 6043-208045-20 6045-208046-208047-20 6047-208245-20 6245-208243-20 6243-208247-20 6247-20
top related