Generalized Waste Containment System
-
Generalized Waste Containment System
-
Linear System RequirementsSubtitle C liner -40 CFR Part 264; Subpart N -264.301 Design & Operating Requirements.Subtitle D liner -40 CFR Part 258; Subpart D -258.40 Design Criteria
-
Subtitle C Liner SystemLiner System should include:1. top liner (e.g. geomembrane)2. composite bottom liner e.g. geomembrane + compacted clay compacted clay -must be at least 3 ft thick - ksat should be no greater than 1x10-7cm/sec
-
Subtitle C Liner System3. Leachate Collection and Removal System above top liner -leachate depth should not exceed 1ft (30cm) 4. Leachate Collection and removal System between liners.
-
LCRS Requirementsbottom slope 1%
at least 1 ft thick gravel layergeonet with transmissivity >no clogging
-
Subtitle C Liner System
-
Subtitle D Liner SystemDesign must ensure that concentration values in Table.1 are not exceed in the uppermost aquiferComposite liner -min 30 mil flexible membrane liner (FML) -compacted clay (at least 2 ft thick - > -HDPE, then min 60 mil )
-
Subtitle D Liner System
-
Barrier MaterialCompacted clay (soil liner)Soil-Bentonite blendsFMLs or GeomembranesGeosynthetic clay liner
-
Compacted ClayRef: Daniel and Koerner (Chapter 3)Material selectionLaboratory TestingTest pads-Field TestingConstruction Quality Control
-
Material Selection for CCLs Soil PlasticityPercentage of FinesPercentage of GravelMaximum Particle size
-
Necessary Soil Mechanics BackgroundWater content Particle Size Distribution -Sieve analysis -Sedimentation analysisAtterberg limitsSoil ClassificationSoil CompactionSoil Permeability