FERROUS MATERIAL HANDLINGPERMANENT LIFTING MAGNETS

Dimensions are in inches. Maw = Maximum allowed weight on AISI 1020

Art - N°Maw in lbs

on flatMaw in lbs on round

MinimumThickness for100% force

DiameterMin/max

ØA B C D E

Weight (lbs)

20.01.100 220 110 0.59 1.18/7.87 4.92 2.67 2.75 2.12 1.57 9

20.01.250 550 275 0.98 1.18/7.09 7.51 3.85 3.42 2.75 1.96 21

20.01.500 1100 475 1.18 1.18/7.09 10.03 3.85 3.42 2.79 1.96 28.50

20.01.1000 2200 990 1.97 7.87/23.62 13.77 5.51 4.44 4.13 2.55 69.50

20.01.2000 4400 1790 2.36 1.57/11.81 17.32 7.08 6.69 4.92 2.36 187

20.01.3000 6600 2646 3.14 7.87/15.74 18.89 8.66 8.46 7.87 3.54 419

20.01.5000 11000 4950 3.93 7.87/15.74 21.25 14.56 12.40 9.05 3.93 882

APPLICATIONPermanent lifting magnets are used for handling of ferrous materials, both flat and round, with raw or machined surface. A 3:1 safety ratio.

exeCuTIONThis new range of lifting magnets ensures SAFE, QUICK and ECONOMIC handling.The Highest energy NEODYMIUM magnets allow to safely handle ferrous materials (no power supply required). The holding force remains constant with time.

The robust ON/OFF switch mechanism is equipped with a safety device preventing unintentional operation.

BRAILLON QUALITY SINCE 1921

«EveryonerememberstheirfirstBraillon»

FERROUS MATERIAL HANDLINGPERMANENT LIFTING MAGNETS

Braillon Magnetics ZI ALPESPACE – BP 6

73806 MONTMELIAN Cedex FRANCEPhone +33 (0)479 842 145

Fax +33 (0)479 841 449info@braillon.com

Braillon Magnetic Systems Inc.2333 Wisconsin AveDowners Grove 60515 IL – USAPhone 312.912.13.55usa@braillon.comwww.braillon.com

HOT APPLICATIONUsed for handling high temperature ferrous material. Up to 250° (482°F). A 3:1 safety ratio.

THIN SHeeT APPLICATIONUsed for handling thin steel sheet. On raw or machined surfaces. A 3:1 safety ratio.

Dimensions are in inches. Maw = Maximum allowed weight on AISI 1020

Art - N° Maw on flat Minimum Thickness for 100% force A B C D E Weight (lbs)

20.01.TF.180 397 0.39 8.07 3.86 3.93 2.56 1.97 24

20.01.TF.300 661 0.59 10.08 3.86 3.93 2.95 1.97 33

Dimensions are in inches. Maw = Maximum allowed weight on AISI 1020

Art - N°Maw in lbs

on flatMaw in lbs on round

MinimumThickness for100% force

DiameterMin/max

ØA B C D E

Weight (lbs)

20.01.HT.200 440 220 0.98 1.18/7.08 7.52 3.86 3.42 2.72 1.97 20

20.01.HT.400 880 440 1.18 1.18/7.08 10.04 3.86 3.42 2.75 1.97 35

20.01.HT.800 1760 880 1.97 7.87/23.62 13.77 5.51 4.44 4.13 2.55 80