product catalogue - concord refrigeration · as part of the southey group, concord refrigeration...
Post on 09-Sep-2018
215 Views
Preview:
TRANSCRIPT
R E F R I G E R A T I O N
P R O D U C T C A T A L O G U E
FRESH MEAT
FROZEN VEGETABLES
ICE CREAM
YOGHURT
HOT PIES
COLD MEATS
CHEESE
As one of South Africa’s leading manufacturers of refrigerated
and heated supermarket display cases, Concord Refrigeration
has been providing retail solutions for over 40 years. Since
1969, we have identified a need for our specialized services
within the refrigeration industry. Our product range is designed
to international standards, coupled with the latest trends and
advancements in technology, this simply results in a superior
performance case.
Operating from state-of-the-art recently extended premises,
Concord Refrigeration incorporates a fully functional design
centre. You are welcomed by a dynamic and experienced team
whose focus is affording you and your projects the best service
and advice available.
With a goal of ensuring your peace of mind from start to finish,
Concord Refrigeration recognizes that success is wholly dependent
on an ability to distinguish individual customer’s needs.
A B O U T C O N C O R D R E F R I G E R A T I O NR E F R I G E R A T I O N
1
As part of the Southey Group, Concord Refrigeration
has the backing and expertise of one of the largest
privately owned groups in South Africa. Founded in 1939,
Southey Holdings is the driving force behind a diverse
and growing number of autonomous, decentralised
businesses and represents one of the most respected
Groups in South Africa. Originally based in Southern
Africa, Southey Holdings now operates from permanent
establishments spread throughout the whole of Africa
and the Middle East.
T H E S O U T H E Y G R O U P
2
INVESTORS IN EXCELLENCE
As part of the Southey Group, Concord Refrigeration
has the backing and expertise of one of the largest
privately owned groups in South Africa. Founded in 1939,
Southey Holdings is the driving force behind a diverse
and growing number of autonomous, decentralised
businesses and represents one of the most respected
Groups in South Africa. Originally based in Southern
Africa, Southey Holdings now operates from permanent
establishments spread throughout the whole of Africa
and the Middle East.
T H E S O U T H E Y G R O U P
C O N T E N T S
32
BUTCHERY
Uprights 6 Personal Service 8Multi-Deck 10Dual S 11
DAIRY
Uprights 14 Gondolo Ends 16Frameless Glass Doors 18
PRODUCE
Uprights 32
READY-TO-EAT
BAKERYPersonal Service 36DELIPersonal Service 38Hot Foods 40Pie Warmers 42Dual Service 44Corner Units 46Multi-Deck Chillers 48Uprights 49
FREEZERS
Glass Door Uprights 22 Crown End Jumbo Freezers 24Combi 26Self Service 27Self Contained Units 28
INVESTORS IN EXCELLENCE
4
FILLET STEAK
FRESH CHICKEN
LAMB CHOPS
BOEREWORS
PORK SAUSAGES
BEEF MINCE
ROAST LAMB
B UTCHERY
5
UPRIGHTSPERSONAL SERVICEMULTI-DECKDUAL
R E F R I G E R A T I O N
Please note- we continually improve our products, specifications and design. Therefore we cannot be held liable for upgrading previously sold equipment to new specifications. Please contact a sales representative for advice or visit www.concordrefrigeration.co.za. Terms & conditions apply. E&OE.
*CABINET DISPLAY TEMPERATURE REF CAP EVAP OFF CYCLE ELECTRICAL **OPTIONAL
LENGTH SURFACE RANGE WATTS TEMP DEFROST REQUIREMENTS DEFROST
2100mm 4.41 m2 0ºc TO +2ºc 3210 -9ºc 30 MIN 1588 WATTS 900 WATTS
2440mm 5.12m2 0ºc TO +2ºc 3880 -9ºc 30 MIN 1630 WATTS 1000 WATTS
3660mm 7.69 m2 0ºc TO +2ºc 5820 -9ºc 30 MIN 2451 WATTS 1500 WATTS
*Add 45mm for each patch end. The above specification is based on standard conditions of 25ºC - 60% RH.
** Add to electrical requirements.
CLASSIC UPRIGHT
SPECIFICATION
BU
TC
HE
RY
6
BU
TC
HE
RY
*CABINET DISPLAY TEMPERATURE REF CAP EVAP OFF CYCLE ELECTRICAL **OPTIONAL
LENGTH SURFACE RANGE WATTS TEMP DEFROST REQUIREMENTS DEFROST
2100mm 4.41 m2 0ºc TO +2ºc 3210 -9ºc 30 MIN 1588 WATTS 900 WATTS
2440mm 5.12m2 0ºc TO +2ºc 3880 -9ºc 30 MIN 1630 WATTS 1000 WATTS
3660mm 7.69 m2 0ºc TO +2ºc 5820 -9ºc 30 MIN 2451 WATTS 1500 WATTS
NEW-GEN UPRIGHT
SPECIFICATION
7
*Add 45mm for each patch end. The above specification is based on standard conditions of 25ºC - 60% RH. ** Add to electrical requirements.
BU
TC
HE
RY
8
*CABINET DISPLAY TEMPERATURE REF CAP EVAP OFF CYCLE ELECTRICAL **OPTIONAL
LENGTH SURFACE RANGE WATTS TEMP DEFROST REQUIREMENTS DEFROST
1220mm 0.85m2 0ºc TO +2ºc 450 -8ºc 30 MIN 420 WATTS 600 WATTS
1830mm 1.28m2 0ºc TO +2ºc 675 -8ºc 30 MIN 722 WATTS 800 WATTS
2440mm 1.70 m2 0ºc TO +2ºc 900 -8ºc 30 MIN 862 WATTS 1000 WATTS
3660mm 2.56 m2 0ºc TO +2ºc 1350 -8ºc 30 MIN 1390 WATTS 1500 WATTS
C U R V E D G L A S S
PERSONAL SERVICE
SPECIFICATION
*Add 45mm for each patch end. The above specification is based on standard conditions of 25ºC - 60% RH.
** Add to electrical requirements.
*CABINET DISPLAY TEMPERATURE REF CAP EVAP OFF CYCLE ELECTRICAL **OPTIONAL
LENGTH SURFACE RANGE WATTS TEMP DEFROST REQUIREMENTS DEFROST
1220mm 0.85m2 0ºc TO +2ºc 450 -8ºc 30 MIN 420 WATTS 600 WATTS
1830mm 1.28m2 0ºc TO +2ºc 675 -8ºc 30 MIN 722 WATTS 800 WATTS
2440mm 1.70 m2 0ºc TO +2ºc 900 -8ºc 30 MIN 862 WATTS 1000 WATTS
SPECIFICATION
1227
537
1061
806
552
241
262
1161
BU
TC
HE
RY
9
PERSONAL SERVICES Q U A R E G L A S S
*Add 45mm for each patch end. The above specification is based on standard conditions of 25ºC - 60% RH. ** Add to electrical requirements.
1858
1891
1227
483 483
AVA I L A B L E I N 2 O R 3 S H E L FB
UT
CH
ER
Y
10
LOW MULTI-DECK CHILLER
*CABINET DISPLAY TEMPERATURE REF CAP EVAP OFF CYCLE ELECTRICAL **OPTIONAL
LENGTH SURFACE RANGE WATTS TEMP DEFROST REQUIREMENTS DEFROST
1830mm 3.37m2 0ºc TO +2ºc 2920 -9ºc 25 MIN 880 WATTS 900 WATTS
2440mm 4.49 m2 0ºc TO +2ºc 3350 -9ºc 25 MIN 880 WATTS 1000 WATTS
3660mm 6.73 m2 0ºc TO +2ºc 5000 -9ºc 25 MIN 1320 WATTS 1500 WATTS
SPECIFICATION
*Add 45mm for each patch end. The above specification is based on standard conditions of 25ºC - 60% RH.
** Add to electrical requirements.
BU
TC
HE
RY
11
*CABINET DISPLAY TEMPERATURE REF CAP EVAP OFF CYCLE ELECTRICAL **OPTIONAL
LENGTH SURFACE RANGE WATTS TEMP DEFROST REQUIREMENTS DEFROST
1830mm 3.37m2 0ºc TO +2ºc 2920 -9ºc 25 MIN 880 WATTS 900 WATTS
2440mm 4.49 m2 0ºc TO +2ºc 3350 -9ºc 25 MIN 880 WATTS 1000 WATTS
3660mm 6.73 m2 0ºc TO +2ºc 5000 -9ºc 25 MIN 1320 WATTS 1500 WATTS
T O P A N D B O T T O M C O L D
DUAL SERVICE
SPECIFICATION
*Add 45mm for each patch end. The above specification is based on standard conditions of 25ºC - 60% RH. ** Add to electrical requirements.
12
BUTTER
YOUGHURT
FRESH MILK
CREAM
CHEESE
FRUIT JUICE
MARGARINE
DAIRY
13
UPRIGHTSGONDOLO ENDSFRAMELESS GLASS DOORS
R E F R I G E R A T I O N
Please note- we continually improve our products, specifications and design. Therefore we cannot be held liable for upgrading previously sold equipment to new specifications. Please contact a sales representative for advice or visit www.concordrefrigeration.co.za. Terms & conditions apply. E&OE.
NEW-GEN UPRIGHTDA
IRY
14
*Add 45mm for each patch end. The above specification is based on standard conditions of 25ºC - 60% RH.
** Add to electrical requirements.
*CABINET DISPLAY TEMPERATURE REF CAP EVAP OFF CYCLE ELECTRICAL **OPTIONAL **OPTIONAL
LENGTH SURFACE RANGE WATTS TEMP DEFROST REQUIREMENTS DEFROST LIGHTING
2100mm 5.46 m2 +3ºc TO +5ºc 2920 -6ºc 25 MIN 708 WATTS 900 WATTS 880 WATTS
2440mm 5.12m2 +3ºc TO +5ºc 3350 -6ºc 25 MIN 750 WATTS 1000 WATTS 880 WATTS
3660mm 7.69 m2 +3ºc TO +5ºc 5000 -6ºc 25 MIN 1131 WATTS 1500 WATTS 1320 WATTS
SPECIFICATION
DA
IRY
15
*CABINET DISPLAY TEMPERATURE REF CAP EVAP OFF CYCLE ELECTRICAL **OPTIONAL **OPTIONAL
LENGTH SURFACE RANGE WATTS TEMP DEFROST REQUIREMENTS DEFROST LIGHTING
2100mm 5.46 m2 +3ºc TO +5ºc 2920 -6ºc 25 MIN 708 WATTS 900 WATTS 880 WATTS
2440mm 5.12m2 +3ºc TO +5ºc 3350 -6ºc 25 MIN 750 WATTS 1000 WATTS 880 WATTS
3660mm 7.69 m2 +3ºc TO +5ºc 5000 -6ºc 25 MIN 1131 WATTS 1500 WATTS 1320 WATTS
CLASSIC UPRIGHT
SPECIFICATION
*Add 45mm for each patch end. The above specification is based on standard conditions of 25ºC - 60% RH. ** Add to electrical requirements.
DA
IRY
16
NEW-GEN GONDOLA END
*CABINET DISPLAY TEMPERATURE REF CAP EVAP OFF CYCLE ELECTRICAL **OPTIONAL **OPTIONAL
LENGTH SURFACE RANGE WATTS TEMP DEFROST REQUIREMENTS DEFROST LIGHTING
2100mm 5.46 m2 +1ºc 2920 -6ºc 25 MIN 708 WATTS 900 WATTS 880 WATTS
SPECIFICATION
*Add 45mm for each patch end. The above specification is based on standard conditions of 25ºC - 60% RH.
** Add to electrical requirements.
DA
IRY
17
*CABINET DISPLAY TEMPERATURE REF CAP EVAP OFF CYCLE ELECTRICAL **OPTIONAL **OPTIONAL
LENGTH SURFACE RANGE WATTS TEMP DEFROST REQUIREMENTS DEFROST LIGHTING
2100mm 5.46 m2 +1ºc 2920 -6ºc 25 MIN 708 WATTS 900 WATTS 880 WATTS
SPECIFICATION
*Add 45mm for each patch end. The above specification is based on standard conditions of 25ºC - 60% RH. ** Add to electrical requirements.
CLASSIC GONDOLA END
*Add 45mm for each patch end. The above specification is based on standard conditions of 25ºC - 60% RH.
** Add to electrical requirements.
DA
IRY
18
NEW-GEN FRAMELESS
*CABINET DISPLAY MODEL TEMPERATURE REF CAP EVAP OFF CYCLE ELECTRICAL **OPTIONAL **OPTIONAL
LENGTH SURFACE RANGE WATTS TEMP DEFROST REQUIREMENTS DEFROST LIGHTING
2100mm 5.46 m2 3 DOOR +3ºc TO +5ºc 2920 -6ºc 25 MIN 708 WATTS 900 WATTS 880 WATTS
2440mm 5.12m2 4 DOOR +3ºc TO +5ºc 3350 -6ºc 25 MIN 750 WATTS 1000 WATTS 880 WATTS
3660mm 7.69 m2 6 DOOR +3ºc TO +5ºc 5000 -6ºc 25 MIN 1131 WATTS 1500 WATTS 1320 WATTS
SPECIFICATION
370
1026711 - 0100+
19
BUTTER
YOUGHURT
FRESH MILK
CREAM
CHEESE
FRUIT JUICE
MARGARINE
20
FROZEN VEGETABLES
FROZEN MEAT
SEAFOOD
ICE CREAM
CRUMBED CHICKEN
FROZEN YOGHURT
READY MEALS
FREEZERS
21
R E F R I G E R A T I O N
Please note- we continually improve our products, specifications and design. Therefore we cannot be held liable for upgrading previously sold equipment to new specifications. Please contact a sales representative for advice or visit www.concordrefrigeration.co.za. Terms & conditions apply. E&OE.
GLASS DOOR UPRIGHTSCROWN END JUMBO FREEZERSCOMBISELF SERVICESELF CONTAINED UNITS
FR
EE
ZE
RS
22
*CABINET DISPLAY TEMPERATURE REF CAP EVAP ELECTRIC ELECTRICAL REQUIREMENTS
LENGTH SURFACE RANGE WATTS TEMP DEFROST WATTS AMPS VOLTS REQ. CIRCUIT
2 DOOR 4.8m2 -18ºc TO -20ºc 1150 -28ºc 2850 WATTS 4720 21.5-3ph 380 15A
3 DOOR 1.28m2 -18ºc TO -20ºc 1600 -28ºc 3750 WATTS 6115 27.8-3ph 380 15A
4 DOOR 1.70 m2 -18ºc TO -20ºc 2100 -28ºc 4950 WATTS 7810 35.5-3ph 380 15A
5 DOOR 2.56 m2 -18ºc TO -20ºc 2600 -28ºc 6600 WATTS 9955 45.3-3ph 380 20A
NEW-GEN GLASS DOOR
*Add 45mm for each patch end. The above specification is based on standard conditions of 25ºC - 60% RH.
** Add to electrical requirements.
SPECIFICATION
FR
EE
ZE
RS
23
*Add 45mm for each patch end. The above specification is based on standard conditions of 25ºC - 60% RH. ** Add to electrical requirements.
CLASSIC GLASS DOOR
*CABINET DISPLAY TEMPERATURE REF CAP EVAP ELECTRIC ELECTRICAL REQUIREMENTS
LENGTH SURFACE RANGE WATTS TEMP DEFROST WATTS AMPS VOLTS REQ. CIRCUIT
2 DOOR 4.8m2 -18ºc TO -20ºc 1150 -28ºc 2850 WATTS 4720 21.5-3ph 380 15A
3 DOOR 1.28m2 -18ºc TO -20ºc 1600 -28ºc 3750 WATTS 6115 27.8-3ph 380 15A
4 DOOR 1.70 m2 -18ºc TO -20ºc 2100 -28ºc 4950 WATTS 7810 35.5-3ph 380 15A
5 DOOR 2.56 m2 -18ºc TO -20ºc 2600 -28ºc 6600 WATTS 9955 45.3-3ph 380 20A
SPECIFICATION
FR
EE
ZE
RS
24
*CABINET DISPLAY TEMPERATURE REF CAP EVAP DEFROST ELECTRIC ELECTRICAL REQUIREMENTS
LENGTH SURFACE RANGE WATTS TEMP TIME DEFROST WATTS AMPS VOLTS REQ. CIRCUIT
3390mm 5,3m2 -18ºc TO -20ºc 3050 -31ºc 30 MIN 5400 WATTS 6438 29.3-3ph 380 10A
C/END 1,4m2 -18ºc TO -20ºc 1100 -31ºc 30 MIN 2400 WATTS 2796 12.7ph 220 15A
2440mm 3,9 m2 -18ºc TO -20ºc 1950 -31ºc 30 MIN 3000 WATTS 3642 16.6-3ph 380 10A
SPECIFICATION
*Add 50mm for each patch end. The above specification is based on standard conditions of 25ºC - 60% RH.
** Add to electrical requirements.
CLASSIC CROWN END JUMBO GLASS
FR
EE
ZE
RS
25
*CABINET DISPLAY TEMPERATURE REF CAP EVAP DEFROST ELECTRIC ELECTRICAL REQUIREMENTS
LENGTH SURFACE RANGE WATTS TEMP TIME DEFROST WATTS AMPS VOLTS REQ. CIRCUIT
3390mm 5,3m2 -18ºc TO -20ºc 3050 -31ºc 30 MIN 5400 WATTS 6438 29.3-3ph 380 10A
C/END 1,4m2 -18ºc TO -20ºc 1100 -31ºc 30 MIN 2400 WATTS 2796 12.7ph 220 15A
2440mm 3,9 m2 -18ºc TO -20ºc 1950 -31ºc 30 MIN 3000 WATTS 3642 16.6-3ph 380 10A
NEW-GEN CROWN END JUMBO GLASS
SPECIFICATION
*Add 50mm for each patch end. The above specification is based on standard conditions of 25ºC - 60% RH. ** Add to electrical requirements.
FR
EE
ZE
RS
26
SPECIFICATION
*Add 50mm for each patch end. The above specification is based on standard conditions of 25ºC - 60% RH.
** Add to electrical requirements.
*CABINET DISPLAY TEMPERATURE REF CAP EVAP DEFROST ELECTRIC ELECTRICAL REQUIREMENTS
LENGTH SURFACE RANGE WATTS TEMP TIME DEFROST WATTS AMPS VOLTS REQ. CIRCUIT
3660mm 5,3m2 -18ºc TO -20ºc 3050 -31ºc 30 MIN 5400 WATTS 6438 29.3-3ph 380 10A
2440mm 3,9 m2 -18ºc TO -20ºc 1950 -31ºc 30 MIN 3000 WATTS 3642 16.6-3ph 380 10A
93
60
3060
39 31
1.6
380
898
998
800
375
135
782
2103
455
713
320
685
1970
512
450 450
2440
2540
3660
3760
COMBI FREEZER
FR
EE
ZE
RS
27
SELF SERVICE BIN FREEZER
SPECIFICATION
470
135
620
810
RE
AR
TR
EN
CH
LIN
E75
0
DR
AIN
AG
E
220
DR
AIN
AG
E
790
1000
*Add 50mm for each patch end. The above specification is based on standard conditions of 25ºC - 60% RH. ** Add to electrical requirements.
*CABINET DISPLAY TEMPERATURE REF CAP EVAP OFF CYCLES ELECTRIC ELECTRICAL REQUIREMENTS
LENGTH SURFACE RANGE WATTS TEMP DEFROST DEFROST WATTS AMPS VOLTS REQ. CIRCUIT
2440mm 1.71m2 -24ºc 1550 -30ºc 30 MIN 2600 WATTS 3594 16.3-3ph 380 10A
3660mm 2.56m2 -24ºc 2300 -30ºc 30 MIN 3000 WATTS 4593 20.9-3ph 380 15A
FR
EE
ZE
RS
28
MODEL LENGTH HEIGHT DEPTH CAPACITY TEMP RANGE
SMR LSL 1940 1940mm 765/905mm 870mm 623L -24ºc to -16ºc
SMR LSL 2500 2500mm 840mm 880mm 938L -24ºc to -16ºc
SMR 1700 PRIME 1700mm 930mm 830mm 706L -24ºc to -16ºc
SMR 2200 PRIME 2200mm 930mm 830mm 964L -24ºc to -16ºc
SELF CONTAINED FREEZER
L I N E A R S TA N D A R D
*Add 50mm for each patch end. The above specification is based on standard conditions of 25ºC - 60% RH.
** Add to electrical requirements.
P R I M E C L A S S I C
29
FROZEN VEGETABLES
FROZEN MEAT
SEAFOOD
ICE CREAM
CRUMBED CHICKEN
FROZEN YOGHURT
READY MEALS
30
APPLES
CUCUMBER
SWEET PEPPERS
LETTUCE
TOMATOES
CARROTS
AUBERGINE
P RODUCE
31
R E F R I G E R A T I O N
Please note- we continually improve our products, specifications and design. Therefore we cannot be held liable for upgrading previously sold equipment to new specifications. Please contact a sales representative for advice or visit www.concordrefrigeration.co.za. Terms & conditions apply. E&OE.
CLASSIC UPRIGHTNEW-GEN UPRIGHT
PR
OD
UC
E
32
*CABINET DISPLAY TEMPERATURE REF CAP EVAP OFF CYCLE ELECTRICAL **OPTIONAL
LENGTH SURFACE RANGE WATTS TEMP DEFROST REQUIREMENTS SHELF/LIGHTING ELEC/DEFROST
2100mm 4.46m2 +3ºc TO +5ºc 2665 -4ºc 20 MIN 708 WATTS 880 WATTS 900 WATTS
2440mm 6.34 m2 +3ºc TO +5ºc 3100 -4ºc 20 MIN 750 WATTS 880 WATTS 1000 WATTS
3660mm 9.52 m2 +3ºc TO +5ºc 4600 -4ºc 20 MIN 1131 WATTS 1320 WATTS 1500 WATTS
CLASSIC UPRIGHT
2100
SPECIFICATION
*Add 45mm for each patch end. The above specification is based on standard conditions of 25ºC - 60% RH.
** Add to electrical requirements.
PR
OD
UC
E
33
*CABINET DISPLAY TEMPERATURE REF CAP EVAP OFF CYCLE ELECTRICAL **OPTIONAL
LENGTH SURFACE RANGE WATTS TEMP DEFROST REQUIREMENTS SHELF/LIGHTING ELEC/DEFROST
2100mm 4.46m2 +3ºc TO +5ºc 2665 -4ºc 20 MIN 708 WATTS 880 WATTS 900 WATTS
2440mm 6.34 m2 +3ºc TO +5ºc 3100 -4ºc 20 MIN 750 WATTS 880 WATTS 1000 WATTS
3660mm 9.52 m2 +3ºc TO +5ºc 4600 -4ºc 20 MIN 1131 WATTS 1320 WATTS 1500 WATTS
2100
SPECIFICATION
*Add 45mm for each patch end. The above specification is based on standard conditions of 25ºC - 60% RH. ** Add to electrical requirements.
NEW-GEN UPRIGHT
34
CHARGRILLED HAM
SMOKED CHICKEN
PARMESAN CHEESE
HOT PIES
SALAMI
PASTRAMI
SUN-DRIED TOMATOES
REA DY-TO-EAT
35
R E F R I G E R A T I O N
Please note- we continually improve our products, specifications and design. Therefore we cannot be held liable for upgrading previously sold equipment to new specifications. Please contact a sales representative for advice or visit www.concordrefrigeration.co.za. Terms & conditions apply. E&OE.
BAKERYPersonal ServiceDELIPersonal ServiceHot FoodsPie WarmersDual ServiceCorner UnitsMulti-Deck ChillersUprights
RE
AD
Y-
TO
-E
AT
36
*CABINET DISPLAY TEMPERATURE REF CAP EVAP OFF CYCLE ELECTRICAL **OPTIONAL
LENGTH SURFACE RANGE WATTS TEMP DEFROST REQUIREMENTS DEFROST
1220mm 0.85m2 0ºc TO +2ºc 450 -8ºc 30 MIN 420 WATTS 600 WATTS
1830mm 1.28m2 0ºc TO +2ºc 675 -8ºc 30 MIN 722 WATTS 800 WATTS
2440mm 1.70 m2 0ºc TO +2ºc 900 -8ºc 30 MIN 862 WATTS 1000 WATTS
3660mm 2.56 m2 0ºc TO +2ºc 1350 -8ºc 30 MIN 1390 WATTS 1500 WATTS
B A K E R Y - C U R V E D G L A S S
PERSONAL SERVICE
SPECIFICATION
*Add 45mm for each patch end. The above specification is based on standard conditions of 25ºC - 60% RH.
** Add to electrical requirements.
RE
AD
Y-
TO
-E
AT
37
*Add 45mm for each patch end. The above specification is based on standard conditions of 25ºC - 60% RH. ** Add to electrical requirements.
*CABINET DISPLAY TEMPERATURE REF CAP EVAP OFF CYCLE ELECTRICAL **OPTIONAL
LENGTH SURFACE RANGE WATTS TEMP DEFROST REQUIREMENTS DEFROST
1220mm 0.85m2 0ºc TO +2ºc 450 -8ºc 30 MIN 420 WATTS 600 WATTS
1830mm 1.28m2 0ºc TO +2ºc 675 -8ºc 30 MIN 722 WATTS 800 WATTS
2440mm 1.70 m2 0ºc TO +2ºc 900 -8ºc 30 MIN 862 WATTS 1000 WATTS
B A K E R Y - S Q U A R E G L A S S
PERSONAL SERVICE
SPECIFICATION
1227
537
1061
806
552
241
262
1161
1858
1891
1227
483 483
RE
AD
Y-
TO
-E
AT
38
*CABINET DISPLAY TEMPERATURE REF CAP EVAP OFF CYCLE ELECTRICAL **OPTIONAL
LENGTH SURFACE RANGE WATTS TEMP DEFROST REQUIREMENTS DEFROST
1220mm 0.85m2 0ºc TO +2ºc 450 -8ºc 30 MIN 420 WATTS 600 WATTS
1830mm 1.28m2 0ºc TO +2ºc 675 -8ºc 30 MIN 722 WATTS 800 WATTS
2440mm 1.70 m2 0ºc TO +2ºc 900 -8ºc 30 MIN 862 WATTS 1000 WATTS
3660mm 2.56 m2 0ºc TO +2ºc 1350 -8ºc 30 MIN 1390 WATTS 1500 WATTS
SPECIFICATION
D E L I - C U R V E D G L A S S
PERSONAL SERVICE
*Add 45mm for each patch end. The above specification is based on standard conditions of 25ºC - 60% RH.
** Add to electrical requirements.
RE
AD
Y-
TO
-E
AT
39
*Add 45mm for each patch end. The above specification is based on standard conditions of 25ºC - 60% RH. ** Add to electrical requirements.
*CABINET DISPLAY TEMPERATURE REF CAP EVAP OFF CYCLE ELECTRICAL **OPTIONAL
LENGTH SURFACE RANGE WATTS TEMP DEFROST REQUIREMENTS DEFROST
1220mm 0.85m2 0ºc TO +2ºc 450 -8ºc 30 MIN 420 WATTS 600 WATTS
1830mm 1.28m2 0ºc TO +2ºc 675 -8ºc 30 MIN 722 WATTS 800 WATTS
2440mm 1.70 m2 0ºc TO +2ºc 900 -8ºc 30 MIN 862 WATTS 1000 WATTS
3660mm 2.56 m2 0ºc TO +2ºc 1350 -8ºc 30 MIN 1390 WATTS 1500 WATTS
D E L I - S Q U A R E G L A S S
PERSONAL SERVICE
SPECIFICATION
1227
537
1061
806
552
241
262
1161
RE
AD
Y-
TO
-E
AT
40
*CABINET DISPLAY TEMPERATURE ELECTRICAL REQUIREMENTS
LENGTH SURFACE RANGE WATTS AMPS VOLTS REQ. CIRCUIT
1220mm 1.00m2 60ºc TO 65ºc 2990 13,5 220 20 A
1830mm 1.45m2 60ºc TO 65ºc 4620 21 - 3ph 380 10 A
2440mm 2.00m2 60ºc TO 65ºc 5760 26 - 3ph 380 15 A
3660mm 2.90m2 60ºc TO 65ºc 8590 39 - 3ph 380 20 A
*Add 45mm for each patch end. Humidified cabinets are designed to maintain the temp. of hot foods and are not designed to heat or cook products.
Do not display more food than will be sold within a 2 hour period.
D E L I - C U R V E D G L A S S
HOT FOOD CASE
SPECIFICATION
RE
AD
Y-
TO
-E
AT
41
*Add 45mm for each patch end. Humidified cabinets are designed to maintain the temp. of hot foods and are not designed to heat or cook products. Do not display more food than will be sold within a 2 hour period.
SPECIFICATION*CABINET DISPLAY TEMPERATURE ELECTRICAL REQUIREMENTS
LENGTH SURFACE RANGE WATTS AMPS VOLTS REQ. CIRCUIT
1220mm 1.00m2 60ºc TO 65ºc 2990 13,5 220 20 A
1830mm 1.45m2 60ºc TO 65ºc 4620 21 - 3ph 380 10 A
2440mm 2.00m2 60ºc TO 65ºc 5760 26 - 3ph 380 15 A
3660mm 2.90m2 60ºc TO 65ºc 8590 39 - 3ph 380 20 A
D E L I - S Q U A R E G L A S S
HOT FOOD CASE
1227
537
1061
806
552
241
262
1161
1858
1891
1227
483 483
RE
AD
Y-
TO
-E
AT
42
*CABINET DISPLAY MODEL C MODEL B TEMPERATURE ELECTRICAL REQUIREMENTS
LENGTH SURFACE 1300 HIGH 1230 HIGH RANGE WATTS AMPS VOLTS REQ. CIRCUIT
1220mm 1.45m2 4FW-C 4FW-B 60ºc TO 65ºc 2990 13,5 220 20 A
1830mm 2.18m2 6PW-C 6PW-B 60ºc TO 65ºc 4620 21 - 3ph 380 10 A
C U R V E D G L A S S
PIE WARMER
*Add 45mm for each patch end. Humidified cabinets are designed to maintain the temp. of hot foods and are not designed to heat or cook products.
Do not display more food than will be sold within a 2 hour period.
SPECIFICATION
RE
AD
Y-
TO
-E
AT
43
*Add 45mm for each patch end. Humidified cabinets are designed to maintain the temp. of hot foods and are not designed to heat or cook products. Do not display more food than will be sold within a 2 hour period.
S Q U A R E G L A S S
PIE WARMER
*CABINET DISPLAY MODEL C MODEL B TEMPERATURE ELECTRICAL REQUIREMENTS
LENGTH SURFACE 1300 HIGH 1230 HIGH RANGE WATTS AMPS VOLTS REQ. CIRCUIT
1220mm 1.45m2 4FW-C 4FW-B 60ºc TO 65ºc 2990 13,5 220 20 A
1830mm 2.18m2 6PW-C 6PW-B 60ºc TO 65ºc 4620 21 - 3ph 380 10 A
1227
537
1061
806
552
241
262
1161
SPECIFICATION
RE
AD
Y-
TO
-E
AT
44
*CABINET DISPLAY TEMPERATURE ELECTRICAL REQUIREMENTS
LENGTH SURFACE RANGE WATTS AMPS VOLTS REQ. CIRCUIT
1220mm 1.00m2 60ºc TO 65ºc 2990 13,5 220 20 A
1830mm 1.45m2 60ºc TO 65ºc 4620 21 - 3ph 380 10 A
2440mm 2.00m2 60ºc TO 65ºc 5760 26 - 3ph 380 15 A
3660mm 2.90m2 60ºc TO 65ºc 8590 39 - 3ph 380 20 A
SPECIFICATION
*Add 45mm for each patch end. Humidified cabinets are designed to maintain the temp. of hot foods and are not designed to heat or cook products.
Do not display more food than will be sold within a 2 hour period.
T O P A N D B O T T O M H O T
DUAL SERVICE - HOT
RE
AD
Y-
TO
-E
AT
45
*Add 45mm for each patch end. The above specification is based on standard conditions of 25ºC - 60% RH. ** Add to electrical requirements.
*CABINET DISPLAY TEMPERATURE REF CAP EVAP ELECTRIC ELECTRICAL REQUIREMENTS
LENGTH SURFACE RANGE WATTS TEMP DEFROST WATTS AMPS VOLTS
1220mm 1,76m2 0ºc TO 2ºc 840 -6ºc 510 WATTS 670 3.05 220
1830mm 2.,64m2 0ºc TO 2ºc 1460 -6ºc 770 WATTS 1095 5 220
2440mm 3.50 m2 0ºc TO 2ºc 1675 -6ºc 1020 WATTS 1320 6 220
3660mm 5.27 m2 0ºc TO 2ºc 2500 -6ºc 1530 WATTS 2015 9,15 220
T O P A N D B O T T O M C O L D
DUAL SERVICE - COLD
SPECIFICATION
RE
AD
Y-
TO
-E
AT
46
*CABINET DISPLAY TEMPERATURE REF CAP EVAP ELECTRIC ELECTRICAL REQUIREMENTS
LENGTH SURFACE RANGE WATTS TEMP DEFROST WATTS AMPS VOLTS
1220mm 1,76m2 0ºc TO 2ºc 840 -6ºc 510 WATTS 670 3.05 220
SPECIFICATION
*Add 45mm for each patch end. The above specification is based on standard conditions of 25ºC - 60% RH.
** Add to electrical requirements.
DELI SELF-SERVICE CORNER
200
72380
8
1061
1249
1766
882
RE
AD
Y-
TO
-E
AT
47
*Add 45mm for each patch end. The above specification is based on standard conditions of 25ºC - 60% RH. ** Add to electrical requirements.
CORNER UNIT
SPECIFICATION*CABINET DISPLAY TEMPERATURE REF CAP EVAP ELECTRIC ELECTRICAL REQUIREMENTS
LENGTH SURFACE RANGE WATTS TEMP DEFROST WATTS AMPS VOLTS
1220mm 1,76m2 0ºc TO 2ºc 840 -6ºc 510 WATTS 670 3.05 220
286
220.
5
217.
1 257
722
427
AC
TUA
L (4
40)
419
1220
12171358
889
RE
AD
Y-
TO
-E
AT
48
*CABINET DISPLAY TEMPERATURE REF CAP EVAP OFF CYCLE ELECTRICAL **OPTIONAL **OPTIONAL
LENGTH SURFACE RANGE WATTS TEMP DEFROST REQUIREMENTS DEFROST LIGHTING
2100mm 5.46 m2 +3ºc TO +5ºc 2920 -6ºc 25 MIN 708 WATTS 900 WATTS 880 WATTS
2440mm 5.12m2 +3ºc TO +5ºc 3350 -6ºc 25 MIN 750 WATTS 1000 WATTS 880 WATTS
3660mm 7.69 m2 +3ºc TO +5ºc 5000 -6ºc 25 MIN 1131 WATTS 1500 WATTS 1320 WATTS
CLASSIC UPRIGHT
SPECIFICATION
*Add 45mm for each patch end. The above specification is based on standard conditions of 25ºC - 60% RH.
** Add to electrical requirements.
RE
AD
Y-
TO
-E
AT
49
*CABINET DISPLAY TEMPERATURE REF CAP EVAP OFF CYCLE ELECTRICAL **OPTIONAL **OPTIONAL
LENGTH SURFACE RANGE WATTS TEMP DEFROST REQUIREMENTS DEFROST LIGHTING
2100mm 5.46 m2 +3ºc TO +5ºc 2920 -6ºc 25 MIN 708 WATTS 900 WATTS 880 WATTS
2440mm 5.12m2 +3ºc TO +5ºc 3350 -6ºc 25 MIN 750 WATTS 1000 WATTS 880 WATTS
3660mm 7.69 m2 +3ºc TO +5ºc 5000 -6ºc 25 MIN 1131 WATTS 1500 WATTS 1320 WATTS
SPECIFICATION
*Add 45mm for each patch end. The above specification is based on standard conditions of 25ºC - 60% RH. ** Add to electrical requirements.
NEW-GEN UPRIGHT
RE
AD
Y-
TO
-E
AT
50
*CABINET DISPLAY TEMPERATURE REF CAP EVAP OFF CYCLE ELECTRICAL **OPTIONAL
LENGTH SURFACE RANGE WATTS TEMP DEFROST REQUIREMENTS DEFROST
1830mm 3.37m2 +3ºc TO +5ºc 2920 -6ºc 25 MIN 880 WATTS 900 WATTS
2440mm 4.49 m2 +3ºc TO +5ºc 3350 -6ºc 25 MIN 880 WATTS 1000 WATTS
3660mm 6.73 m2 +3ºc TO +5ºc 5000 -6ºc 25 MIN 1320 WATTS 1500 WATTS
NEW-GEN MULTI-DECK CHILLER
SPECIFICATION
*Add 45mm for each patch end. The above specification is based on standard conditions of 25ºC - 60% RH.
** Add to electrical requirements.
PARMESAN CHEESE
TOASTED SANDWICHES
OLIVE PESTO
SMOKED HAM
PROSCUITO
SUN-DRIED TOMATOES
51
Today, more than ever, enviromental concerns remain
one of the top priorities for any business. At Concord
Refrigeration we are at the forefront of refrigeration
technology and energy saving. Our designs are
continuously improved to ensure optimum efficiency.
From using the latest non-CFC insulation technologies,
to materials that conform to international
environmental standards, Concord Refrigeration is
recognised as one of the market leaders in green
refrigeration manufacturing, partnering with global
leaders in technology.
C O N C O R D A N D T H E E N V I R O N M E N T
52
R E F R I G E R A T I O N
www.concordrefr igerat ion .co .za
top related