room data sheets - tarrant countyaccess.tarrantcounty.com/content/dam/main/purchasing/bids...layouts...
Post on 24-Apr-2020
15 Views
Preview:
TRANSCRIPT
OCTOBER 2014
FUNCTIONAL AND SPACE PROGRAM VOLUME 2:
Room Data Sheets
JOHN PETER SMITH HOSPITAL
Acknowledgements
Steering Committee Members
Staff
Kathleen WhelanVice President, Operations
Trudy SandersVice President, Patient Care
Wanda PeeblesSr. Vice President, Chief Nursing Officer
Jaime PillaiVice President, Support Services
Bill WhitmanExecutive Vice President & COO
Angie MorganDirector, Construction
Scott RuleVice President Physicians
Dr. Robert Reddix President of Medical Staff
Dr. James JohnsonVice President of Medical Staff Board Of Managers - Planning Committee Members
Rev. Ralph EmersonPlanning Committee Chair
Trent O. PettyBoard of Managers Chair
DT NguyenMember
Dorothy DeBoseMember
Charles Powell Finance Committee Chair
Functional & Space Planning Participants
Kathleen Whelan Vice President, Operations
Mike DosseyExecutive Radiology/Lab ServicesUrgent and Emergency Services
Wanda PeeblesSr. Vice President, Chief Nursing Officer
Meg Bryant Administrative DirectorSurgical Services
Deb Saunders Administrative Director
Anne GoodrichDirector, Cardiovascular Services
Trudy SandersVice President, Patient Care
Pat AlridgeExecutive Director, Women’s Services
David Graves Director, Rehabilitation Services
Jim Graves Director, Respiratory Therapy
Reg Scarborough Director, Pharmacy
Jason Limbaugh Director, Materials Management
Jaime Pillai Vice President, Support Services
Celia Krazit Director, Nutritional Services
Tom Colvin Director, Biomed/Patient
Bill Whitman Executive Vice President & COO
Angie Morgan Director, Construction
Melinda CostinChief Information Officer
David Mendenhall Chief Technology Officer
Wayne YoungSenior Vice President, Operations & Administrator - Trinity Springs Pavilion
Dr. Alan Podawiltz, DO, MS, FAPAPsychiatry Department Chairman
Debra SweatExecutive Director of Psychiatric Nursing
Administrative Assistants
Suzy EmersonAdministrative Assistance
Consultants
BroaddusLead Planner,Cost Estimator & Project Management
Blue CottageHealthcare Consultant
Vaughn ConstructionCost Estimator
JE DunnCost Estimator
CCRDMEP Engineers
JQCivil Engineers
Walker EngineeringData/Communications Engineering
Walker EngineeringData/Communications Engineering
RTKLMedical Equipment Consultants
CHAPTER 1:
Room Layouts and Room Data Sheet
1Volume II | Chapter I
Introduction
Purpose of Content
The purpose of this document is to provide Prototype Room Layouts and corresponding Room Data Sheets that will assist with the cost estimating portion of the Functional Planning Services for John Peter Smith (JPS) Hospital in Tarrant County. Moving forward these Prototype Room Layouts and Room Data Sheets will help inform the future design for JPS Hospital. This project is being led by Broaddus & Associates, who are the lead planners, estimators, and project managers, in partnership with Blue Cottage Consulting, healthcare facility programming experts.
5Volume II | Chapter I
68
10121416182022242628303234363840424446485052545658606264666870727476788082848688
Alcove - NurseAlcove - Point of Care TestingAnteroom, ISO, 2 DoorAnteroom, ISO, 3 DoorBottled Gas StorageClean UtilityConsultation, FamilyC-Section Operating RoomCT Scan and ControlElectrical ClosetExam/Treatment RoomGI Endoscopy LabHousekeepingIntermediate Distribution FrameLabor/Delivery/Recovery Room Main Distribution FrameMedicationNICUNourishmentNurse StationOffice - Manager/DirectorOffice - Vice PresidentOffice - Single Open WorkstationOffice - Three-Person SharedOffice - Two-Person SharedPACU RoomPatient Room, BariatricPatient Room, Bariatric ISOPatient Room, ICUPatient Room, ICU ISOPatient Room, PostpartumPatient Room, StandardPatient Room, Standard ISOPre-Op HoldingRecovery RoomRespiratory Therapy StorageScrub AlcoveSoiled HoldingSoiled UtilityStaff LoungeStress Testing LabsTeam Workroom
Index of Prototype Rooms and Room Data Sheets
Index
REMARKS/NOTES:
6
1/4”=1’
Volume II | Chapter I
• Single outlet roughin location with (4) Cat6A cables• Overhead paging speakers in adjacent area corridors
ACTUAL SIZE: 24 S.F.
Prototypical Room Layout (24 Square Feet)
Alcove - Nurse
Room Data Sheet
8 Hours/DayUTILIZATION (HOURS OF USE)
14 Hours/Day24 Hours/Day
PowerELECTRICAL
WallWall Voice, Data, Video, MicFloor PowerFloor Voice, Data, Video, MicInstructor’s ConsoleLightingHouse, GeneralLinear Direct/Indirect FixturesTask LightingLighting ControlsDimmingEmergency Power
No LockSECURITY
Keyed LockCard AccessVideo Surveillance
FloorARCHITECTURAL
VCT (Chemical Resistance)VCTWelded Seam Sheet VinylEpoxyCarpetSealed ConcretePartitionsGyp Board, Epoxy PaintGyp Board, PaintVWCGlassOther: Curtain w/ TrackBase4” RubberIntegral w/ FloorOther:CeilingOpenAcoustical TileGyp BoardDoorWoodMetalVision PanelGlass
Standard Hardware SetDOOR HARDWARE
Automatic Door Operators
Temperature: 70-75F & 30-60% MECHANICAL
Heating & Cooling: Maintain 75FVentilation (Per Code)Acoustical Control15 Air Changes/Hour10 Air Changes/Hour6 Air Changes/Hour100% Make-up AirAir Pressure PositiveAir Pressure NegativeHoodsChemical Fume HoodLaminar Flow HoodBiological Safety CabinetSnorkelCanopy HoodOther:
Hand Washing SinkPLUMBING
Multiple Basin SinkFloor DrainFloor SinkSafety Shower/EyewashReverse Osmosis (RO)Carbon Dioxide (CO2)Nitrogen (N2)Oxygen (O2)Natural GasVacuumNitrous OxideCompressed Air
Suppression SystemFIRE SUPPRESSION/DETECTION
Fire ExtinguisherAlarm System Type:
Voice (Telephone)COMMUNICATIONS
Data (Computer)Data (Print/Scan/Fax)Cable TVCampus Closed Circuit TVNurse CallRFID/RTLSIntercomAssisted Listening
Speaker System - OverheadAUDIO/VISUAL
Presentation - DisplayPresentation - Projector/ScreenPresentation - LecternA/V Touch Control PanelAudio Conferencing
Lighting ControlDimmingAV Equipment in RoomAV Equipment in Comm RoomContent/Lecture RecordingOR Integration & ControlOR Scheduling & ManagementDVD/Blu-Ray PlayerDocument Camera
7
Video Conferencing
Special:ACOUSTICS
STP Wall: STP Floor:
See Appendix Table 1See Appendix Table 1
Electric Hardware Set
Volume II | Chapter I
Alcove - Nurse
REMARKS/NOTES:
8
1/4”=1’
Volume II | Chapter I
• Single outlet roughin location with (2) Cat6A cables• Overhead paging speakers in adjacent area corridors
ACTUAL SIZE: 30 S.F.
Prototypical Room Layout (30 Square Feet)
Alcove - Point of Care Testing
Room Data Sheet
8 Hours/DayUTILIZATION (HOURS OF USE)
14 Hours/Day24 Hours/Day
PowerELECTRICAL
WallWall Voice, Data, Video, MicFloor PowerFloor Voice, Data, Video, MicInstructor’s ConsoleLightingHouse, GeneralLinear Direct/Indirect FixturesTask LightingLighting ControlsDimmingEmergency Power
No LockSECURITY
Keyed LockCard AccessVideo Surveillance
FloorARCHITECTURAL
VCT (Chemical Resistance)VCTWelded Seam Sheet VinylEpoxyCarpetSealed ConcretePartitionsGyp Board, Epoxy PaintGyp Board, PaintVWCGlassOther: Curtain w/ TrackBase4” RubberIntegral w/ FloorOther:CeilingOpenAcoustical TileGyp BoardDoorWoodMetalVision PanelGlass
Standard Hardware SetDOOR HARDWARE
Automatic Door Operators
Temperature: 70-75F & 30-60% MECHANICAL
Heating & Cooling: Maintain 75FVentilation (Per Code)Acoustical Control15 Air Changes/Hour10 Air Changes/Hour6 Air Changes/Hour100% Make-up AirAir Pressure PositiveAir Pressure NegativeHoodsChemical Fume HoodLaminar Flow HoodBiological Safety CabinetSnorkelCanopy HoodOther:
Hand Washing SinkPLUMBING
Multiple Basin SinkFloor DrainFloor SinkSafety Shower/EyewashReverse Osmosis (RO)Carbon Dioxide (CO2)Nitrogen (N2)Oxygen (O2)Natural GasVacuumNitrous OxideCompressed Air
Suppression SystemFIRE SUPPRESSION/DETECTION
Fire ExtinguisherAlarm System Type:
Voice (Telephone)COMMUNICATIONS
Data (Computer)Data (Print/Scan/Fax)Cable TVCampus Closed Circuit TVNurse CallRFID/RTLSIntercomAssisted Listening
Speaker System - OverheadAUDIO/VISUAL
Presentation - DisplayPresentation - Projector/ScreenPresentation - LecternA/V Touch Control PanelAudio Conferencing
Lighting ControlDimmingAV Equipment in RoomAV Equipment in Comm RoomContent/Lecture RecordingOR Integration & ControlOR Scheduling & ManagementDVD/Blu-Ray PlayerDocument Camera
9
Video Conferencing
Special:ACOUSTICS
STP Wall: STP Floor:
Not Applicable
Electric Hardware Set
Volume II | Chapter I
Alcove - Point of Care Testing
REMARKS/NOTES:
10
1/4”=1’
Volume II | Chapter I
• Overhead paging speakers in adjacent area corridors
ACTUAL SIZE: 60 S.F.
Prototypical Room Layout (60 Square Feet)
Anteroom, ISO, 2 Door
Room Data Sheet
8 Hours/DayUTILIZATION (HOURS OF USE)
14 Hours/Day24 Hours/Day
PowerELECTRICAL
WallWall Voice, Data, Video, MicFloor PowerFloor Voice, Data, Video, MicInstructor’s ConsoleLightingHouse, GeneralLinear Direct/Indirect FixturesTask LightingLighting ControlsDimmingEmergency Power
No LockSECURITY
Keyed LockCard AccessVideo Surveillance
FloorARCHITECTURAL
VCT (Chemical Resistance)VCTWelded Seam Sheet VinylEpoxyCarpetSealed ConcretePartitionsGyp Board, Epoxy PaintGyp Board, PaintVWCGlassOther: Curtain w/ TrackBase4” RubberIntegral w/ FloorOther:CeilingOpenAcoustical TileGyp BoardDoorWoodMetalVision PanelGlass
Standard Hardware SetDOOR HARDWARE
Automatic Door Operators
Temperature: 70-75F & 30-60% MECHANICAL
Heating & Cooling: Maintain 75FVentilation (Per Code)Acoustical Control15 Air Changes/Hour10 Air Changes/Hour6 Air Changes/Hour100% Make-up AirAir Pressure PositiveAir Pressure NegativeHoodsChemical Fume HoodLaminar Flow HoodBiological Safety CabinetSnorkelCanopy HoodOther:
Hand Washing SinkPLUMBING
Multiple Basin SinkFloor DrainFloor SinkSafety Shower/EyewashReverse Osmosis (RO)Carbon Dioxide (CO2)Nitrogen (N2)Oxygen (O2)Natural GasVacuumNitrous OxideCompressed Air
Suppression SystemFIRE SUPPRESSION/DETECTION
Fire ExtinguisherAlarm System Type:
Voice (Telephone)COMMUNICATIONS
Data (Computer)Data (Print/Scan/Fax)Cable TVCampus Closed Circuit TVNurse CallRFID/RTLSIntercomAssisted Listening
Speaker System - OverheadAUDIO/VISUAL
Presentation - DisplayPresentation - Projector/ScreenPresentation - LecternA/V Touch Control PanelAudio Conferencing
Lighting ControlDimmingAV Equipment in RoomAV Equipment in Comm RoomContent/Lecture RecordingOR Integration & ControlOR Scheduling & ManagementDVD/Blu-Ray PlayerDocument Camera
11
Video Conferencing
Special:ACOUSTICS
STP Wall: STP Floor:
See Appendix Table 1See Appendix Table 1
Electric Hardware Set
Volume II | Chapter I
Anteroom, ISO, 2 Door
REMARKS/NOTES:
12
1/4”=1’
Volume II | Chapter I
• Overhead paging speakers in adjacent area corridors
ACTUAL SIZE: 60 S.F.
Prototypical Room Layout (60 Square Feet)
Anteroom, ISO, 3 Door
Room Data Sheet
8 Hours/DayUTILIZATION (HOURS OF USE)
14 Hours/Day24 Hours/Day
PowerELECTRICAL
WallWall Voice, Data, Video, MicFloor PowerFloor Voice, Data, Video, MicInstructor’s ConsoleLightingHouse, GeneralLinear Direct/Indirect FixturesTask LightingLighting ControlsDimmingEmergency Power
No LockSECURITY
Keyed LockCard AccessVideo Surveillance
FloorARCHITECTURAL
VCT (Chemical Resistance)VCTWelded Seam Sheet VinylEpoxyCarpetSealed ConcretePartitionsGyp Board, Epoxy PaintGyp Board, PaintVWCGlassOther: Curtain w/ TrackBase4” RubberIntegral w/ FloorOther:CeilingOpenAcoustical TileGyp BoardDoorWoodMetalVision PanelGlass
Standard Hardware SetDOOR HARDWARE
Automatic Door Operators
Temperature: 70-75F & 30-60% MECHANICAL
Heating & Cooling: Maintain 75FVentilation (Per Code)Acoustical Control15 Air Changes/Hour10 Air Changes/Hour6 Air Changes/Hour100% Make-up AirAir Pressure PositiveAir Pressure NegativeHoodsChemical Fume HoodLaminar Flow HoodBiological Safety CabinetSnorkelCanopy HoodOther:
Hand Washing SinkPLUMBING
Multiple Basin SinkFloor DrainFloor SinkSafety Shower/EyewashReverse Osmosis (RO)Carbon Dioxide (CO2)Nitrogen (N2)Oxygen (O2)Natural GasVacuumNitrous OxideCompressed Air
Suppression SystemFIRE SUPPRESSION/DETECTION
Fire ExtinguisherAlarm System Type:
Voice (Telephone)COMMUNICATIONS
Data (Computer)Data (Print/Scan/Fax)Cable TVCampus Closed Circuit TVNurse CallRFID/RTLSIntercomAssisted Listening
Speaker System - OverheadAUDIO/VISUAL
Presentation - DisplayPresentation - Projector/ScreenPresentation - LecternA/V Touch Control PanelAudio Conferencing
Lighting ControlDimmingAV Equipment in RoomAV Equipment in Comm RoomContent/Lecture RecordingOR Integration & ControlOR Scheduling & ManagementDVD/Blu-Ray PlayerDocument Camera
13
Video Conferencing
Special:ACOUSTICS
STP Wall: STP Floor:
See Appendix Table 1See Appendix Table 1
Electric Hardware Set
Volume II | Chapter I
Anteroom, ISO, 3 Door
REMARKS/NOTES:
14
1/4”=1’
Volume II | Chapter I
• Overhead paging speakers in adjacent area corridors
ACTUAL SIZE: 100 S.F.
Prototypical Room Layout (100 Square Feet)
Bottled Gas Storage
Room Data Sheet
8 Hours/DayUTILIZATION (HOURS OF USE)
14 Hours/Day24 Hours/Day
PowerELECTRICAL
WallWall Voice, Data, Video, MicFloor PowerFloor Voice, Data, Video, MicInstructor’s ConsoleLightingHouse, GeneralLinear Direct/Indirect FixturesTask LightingLighting ControlsDimmingEmergency Power
No LockSECURITY
Keyed LockCard AccessVideo Surveillance
FloorARCHITECTURAL
VCT (Chemical Resistance)VCTWelded Seam Sheet VinylEpoxyCarpetSealed ConcretePartitionsGyp Board, Epoxy PaintGyp Board, PaintVWCGlassOther: Curtain w/ TrackBase4” RubberIntegral w/ FloorOther:CeilingOpenAcoustical TileGyp BoardDoorWoodMetalVision PanelGlass
Standard Hardware SetDOOR HARDWARE
Automatic Door Operators
Temperature: 70-75F & 30-60% MECHANICAL
Heating & Cooling: Maintain 75FVentilation (Per Code)Acoustical Control15 Air Changes/Hour10 Air Changes/Hour6 Air Changes/Hour100% Make-up AirAir Pressure PositiveAir Pressure NegativeHoodsChemical Fume HoodLaminar Flow HoodBiological Safety CabinetSnorkelCanopy HoodOther:
Hand Washing SinkPLUMBING
Multiple Basin SinkFloor DrainFloor SinkSafety Shower/EyewashReverse Osmosis (RO)Carbon Dioxide (CO2)Nitrogen (N2)Oxygen (O2)Natural GasVacuumNitrous OxideCompressed Air
Suppression SystemFIRE SUPPRESSION/DETECTION
Fire ExtinguisherAlarm System Type:
Voice (Telephone)COMMUNICATIONS
Data (Computer)Data (Print/Scan/Fax)Cable TVCampus Closed Circuit TVNurse CallRFID/RTLSIntercomAssisted Listening
Speaker System - OverheadAUDIO/VISUAL
Presentation - DisplayPresentation - Projector/ScreenPresentation - LecternA/V Touch Control PanelAudio Conferencing
Lighting ControlDimmingAV Equipment in RoomAV Equipment in Comm RoomContent/Lecture RecordingOR Integration & ControlOR Scheduling & ManagementDVD/Blu-Ray PlayerDocument Camera
15
Video Conferencing
Special:ACOUSTICS
STP Wall: STP Floor:
Not Applicable
Electric Hardware Set
Volume II | Chapter I
Bottled Gas Storage
REMARKS/NOTES:
16
1/4”=1’
Volume II | Chapter I
• Card reader with Clinical Staff access• Single outlet roughin location with (2) Cat6A cables
• Overhead paging speakers in adjacent area corridors• Nurse call duty station requiring a single outlet roughin
• Additional outlets may be needed for inventory control• Wall phone outlet
ACTUAL SIZE: 100 S.F.
Prototypical Room Layout (100 Square Feet)
Clean Utility
Room Data Sheet
8 Hours/DayUTILIZATION (HOURS OF USE)
14 Hours/Day24 Hours/Day
PowerELECTRICAL
WallWall Voice, Data, Video, MicFloor PowerFloor Voice, Data, Video, MicInstructor’s ConsoleLightingHouse, GeneralLinear Direct/Indirect FixturesTask LightingLighting ControlsDimmingEmergency Power
No LockSECURITY
Keyed LockCard AccessVideo Surveillance
FloorARCHITECTURAL
VCT (Chemical Resistance)VCTWelded Seam Sheet VinylEpoxyCarpetSealed ConcretePartitionsGyp Board, Epoxy PaintGyp Board, PaintVWCGlassOther: Curtain w/ TrackBase4” RubberIntegral w/ FloorOther:CeilingOpenAcoustical TileGyp BoardDoorWoodMetalVision PanelGlass
Standard Hardware SetDOOR HARDWARE
Automatic Door Operators
Temperature: 70-75F & 30-60% MECHANICAL
Heating & Cooling: Maintain 75FVentilation (Per Code)Acoustical Control15 Air Changes/Hour10 Air Changes/Hour6 Air Changes/Hour100% Make-up AirAir Pressure PositiveAir Pressure NegativeHoodsChemical Fume HoodLaminar Flow HoodBiological Safety CabinetSnorkelCanopy HoodOther:
Hand Washing SinkPLUMBING
Multiple Basin SinkFloor DrainFloor SinkSafety Shower/EyewashReverse Osmosis (RO)Carbon Dioxide (CO2)Nitrogen (N2)Oxygen (O2)Natural GasVacuumNitrous OxideCompressed Air
Suppression SystemFIRE SUPPRESSION/DETECTION
Fire ExtinguisherAlarm System Type:
Voice (Telephone)COMMUNICATIONS
Data (Computer)Data (Print/Scan/Fax)Cable TVCampus Closed Circuit TVNurse CallRFID/RTLSIntercomAssisted Listening
Speaker System - OverheadAUDIO/VISUAL
Presentation - DisplayPresentation - Projector/ScreenPresentation - LecternA/V Touch Control PanelAudio Conferencing
Lighting ControlDimmingAV Equipment in RoomAV Equipment in Comm RoomContent/Lecture RecordingOR Integration & ControlOR Scheduling & ManagementDVD/Blu-Ray PlayerDocument Camera
17
Video Conferencing
Special:ACOUSTICS
STP Wall: STP Floor:
Not Applicable
Electric Hardware Set
Volume II | Chapter I
Clean Utility
REMARKS/NOTES:
18
1/4”=1’
Volume II | Chapter I
• Single outlet roughin location with (2) Cat6A cables• Overhead paging speakers in adjacent area corridors
ACTUAL SIZE: 100 S.F.
Prototypical Room Layout (100 Square Feet)
Consultation, Family
Room Data Sheet
8 Hours/DayUTILIZATION (HOURS OF USE)
14 Hours/Day24 Hours/Day
PowerELECTRICAL
WallWall Voice, Data, Video, MicFloor PowerFloor Voice, Data, Video, MicInstructor’s ConsoleLightingHouse, GeneralLinear Direct/Indirect FixturesTask LightingLighting ControlsDimmingEmergency Power
No LockSECURITY
Keyed LockCard AccessVideo Surveillance
FloorARCHITECTURAL
VCT (Chemical Resistance)VCTWelded Seam Sheet VinylEpoxyCarpetSealed ConcretePartitionsGyp Board, Epoxy PaintGyp Board, PaintVWCGlassOther: Curtain w/ TrackBase4” RubberIntegral w/ FloorOther:CeilingOpenAcoustical TileGyp BoardDoorWoodMetalVision PanelGlass
Standard Hardware SetDOOR HARDWARE
Automatic Door Operators
Temperature: 70-75F & 30-60% MECHANICAL
Heating & Cooling: Maintain 75FVentilation (Per Code)Acoustical Control15 Air Changes/Hour10 Air Changes/Hour6 Air Changes/Hour100% Make-up AirAir Pressure PositiveAir Pressure NegativeHoodsChemical Fume HoodLaminar Flow HoodBiological Safety CabinetSnorkelCanopy HoodOther:
Hand Washing SinkPLUMBING
Multiple Basin SinkFloor DrainFloor SinkSafety Shower/EyewashReverse Osmosis (RO)Carbon Dioxide (CO2)Nitrogen (N2)Oxygen (O2)Natural GasVacuumNitrous OxideCompressed Air
Suppression SystemFIRE SUPPRESSION/DETECTION
Fire ExtinguisherAlarm System Type:
Voice (Telephone)COMMUNICATIONS
Data (Computer)Data (Print/Scan/Fax)Cable TVCampus Closed Circuit TVNurse CallRFID/RTLSIntercomAssisted Listening
Speaker System - OverheadAUDIO/VISUAL
Presentation - DisplayPresentation - Projector/ScreenPresentation - LecternA/V Touch Control PanelAudio Conferencing
Lighting ControlDimmingAV Equipment in RoomAV Equipment in Comm RoomContent/Lecture RecordingOR Integration & ControlOR Scheduling & ManagementDVD/Blu-Ray PlayerDocument Camera
19
Video Conferencing
ACOUSTICS
Electric Hardware Set
Volume II | Chapter I
Special: Walls to Deck with
Located in WallsSound Batt Insulation
Consultation, Family
20 Volume II | Chapter I
REMARKS/NOTES:
1/4”=1’
• (8) Single outlet wall roughin locations with (2) Cat6A cables• (1) Ceiling outlet roughin with (4) Cat6A cables• (2) Wall Phones with (1) Cat6A cable each
• OR integration system with (4) overhead speakers, (2) cameras, and (2) in-field displays• OR control & management touchscreen wall mounted with (1) Cat6A cable
• (1) Single outlet wall roughin location with (1) RTLS Cat6A cable• (2) Nurse call patient stations requiring a 3-gang outlet roughin• Overhead paging speakers in adjacent area corridors
ACTUAL SIZE: 484 S.F.CODE MIN: 360 S.F.
Prototypical Room Layout (484 Square Feet)
C-Section Operating Room
Room Data Sheet
8 Hours/DayUTILIZATION (HOURS OF USE)
14 Hours/Day24 Hours/Day
PowerELECTRICAL
WallWall Voice, Data, Video, MicFloor PowerFloor Voice, Data, Video, MicInstructor’s ConsoleLightingHouse, GeneralLinear Direct/Indirect FixturesTask LightingLighting ControlsDimmingEmergency Power
No LockSECURITY
Keyed LockCard AccessVideo Surveillance
FloorARCHITECTURAL
VCT (Chemical Resistance)VCTWelded Seam Sheet VinylEpoxyCarpetSealed ConcretePartitionsGyp Board, Epoxy PaintGyp Board, PaintVWCGlassOther: Curtain w/ TrackBase4” RubberIntegral w/ FloorOther:CeilingOpenAcoustical TileGyp BoardDoorWoodMetalVision PanelGlass
Standard Hardware SetDOOR HARDWARE
Automatic Door Operators
Temperature: 70-75F & 30-60% MECHANICAL
Heating & Cooling: Maintain 75FVentilation (Per Code)Acoustical Control15 Air Changes/Hour10 Air Changes/Hour6 Air Changes/Hour100% Make-up AirAir Pressure PositiveAir Pressure NegativeHoodsChemical Fume HoodLaminar Flow HoodBiological Safety CabinetSnorkelCanopy HoodOther:
Hand Washing SinkPLUMBING
Multiple Basin SinkFloor DrainFloor SinkSafety Shower/EyewashReverse Osmosis (RO)Carbon Dioxide (CO2)Nitrogen (N2)Oxygen (O2)Natural GasVacuumNitrous OxideCompressed Air
Suppression SystemFIRE SUPPRESSION/DETECTION
Fire ExtinguisherAlarm System Type:
Voice (Telephone)COMMUNICATIONS
Data (Computer)Data (Print/Scan/Fax)Cable TVCampus Closed Circuit TVNurse CallRFID/RTLSIntercomAssisted Listening
Speaker System - OverheadAUDIO/VISUAL
Presentation - DisplayPresentation - Projector/ScreenPresentation - LecternA/V Touch Control PanelAudio Conferencing
Lighting ControlDimmingAV Equipment in RoomAV Equipment in Comm RoomContent/Lecture RecordingOR Integration & ControlOR Scheduling & ManagementDVD/Blu-Ray PlayerDocument Camera
21
Video Conferencing
Special:ACOUSTICS
STP Wall: STP Floor:
See Appendix Table 1See Appendix Table 1
Electric Hardware Set
Volume II | Chapter I
C-Section Operating Room
REMARKS/NOTES:
22 Volume II | Chapter I
• (3) Single wall outlet roughin locations with (2) Cat6A cables per• Card reader with Clinical Staff access
• (1) Corridor light• Integrated intercom equipment roughin
• Overhead paging speakers in adjacent area corridors• (1) Nurse call patient station requiring a 3-gang outlet roughin
3/16”=1’
Prototypical Room Layout (480 Square Feet)
ACTUAL SIZE: 360 S.F.CONTROL ROOM: 120 S.F.
CT Scan and Control
Room Data Sheet
8 Hours/DayUTILIZATION (HOURS OF USE)
14 Hours/Day24 Hours/Day
PowerELECTRICAL
WallWall Voice, Data, Video, MicFloor PowerFloor Voice, Data, Video, MicInstructor’s ConsoleLightingHouse, GeneralLinear Direct/Indirect FixturesTask LightingLighting ControlsDimmingEmergency Power
No LockSECURITY
Keyed LockCard AccessVideo Surveillance
FloorARCHITECTURAL
VCT (Chemical Resistance)VCTWelded Seam Sheet VinylEpoxyCarpetSealed ConcretePartitionsGyp Board, Epoxy PaintGyp Board, PaintVWCGlassOther: Curtain w/ TrackBase4” RubberIntegral w/ FloorOther:CeilingOpenAcoustical TileGyp BoardDoorWoodMetalVision PanelGlass
Standard Hardware SetDOOR HARDWARE
Automatic Door Operators
Temperature: 70-75F & 30-60% MECHANICAL
Heating & Cooling: Maintain 75FVentilation (Per Code)Acoustical Control15 Air Changes/Hour10 Air Changes/Hour6 Air Changes/Hour100% Make-up AirAir Pressure PositiveAir Pressure NegativeHoodsChemical Fume HoodLaminar Flow HoodBiological Safety CabinetSnorkelCanopy HoodOther:
Hand Washing SinkPLUMBING
Multiple Basin SinkFloor DrainFloor SinkSafety Shower/EyewashReverse Osmosis (RO)Carbon Dioxide (CO2)Nitrogen (N2)Oxygen (O2)Natural GasVacuumNitrous OxideCompressed Air
Suppression SystemFIRE SUPPRESSION/DETECTION
Fire ExtinguisherAlarm System Type:
Voice (Telephone)COMMUNICATIONS
Data (Computer)Data (Print/Scan/Fax)Cable TVCampus Closed Circuit TVNurse CallRFID/RTLSIntercomAssisted Listening
Speaker System - OverheadAUDIO/VISUAL
Presentation - DisplayPresentation - Projector/ScreenPresentation - LecternA/V Touch Control PanelAudio Conferencing
Lighting ControlDimmingAV Equipment in RoomAV Equipment in Comm RoomContent/Lecture RecordingOR Integration & ControlOR Scheduling & ManagementDVD/Blu-Ray PlayerDocument Camera
23
Video Conferencing
Special:ACOUSTICS
STP Wall: STP Floor:
Not Applicable
Electric Hardware Set
Volume II | Chapter I
CT Scan and Control
REMARKS/NOTES:
24
1/4”=1’
Volume II | Chapter I
• Card reader with Facility Staff access• (1) Wall phone with (1) Cat6A cable
ACTUAL SIZE: 200 S.F.
Prototypical Room Layout (200 Square Feet)
Electrical Closet
Room Data Sheet
8 Hours/DayUTILIZATION (HOURS OF USE)
14 Hours/Day24 Hours/Day
PowerELECTRICAL
WallWall Voice, Data, Video, MicFloor PowerFloor Voice, Data, Video, MicInstructor’s ConsoleLightingHouse, GeneralLinear Direct/Indirect FixturesTask LightingLighting ControlsDimmingEmergency Power
No LockSECURITY
Keyed LockCard AccessVideo Surveillance
FloorARCHITECTURAL
VCT (Chemical Resistance)VCTWelded Seam Sheet VinylEpoxyCarpetSealed ConcretePartitionsGyp Board, Epoxy PaintGyp Board, PaintVWCGlassOther: Curtain w/ TrackBase4” RubberIntegral w/ FloorOther:CeilingOpenAcoustical TileGyp BoardDoorWoodMetalVision PanelGlass
Standard Hardware SetDOOR HARDWARE
Automatic Door Operators
Temperature: 70-75F & 30-60% MECHANICAL
Heating & Cooling: Maintain 75FVentilation (Per Code)Acoustical Control15 Air Changes/Hour10 Air Changes/Hour6 Air Changes/Hour100% Make-up AirAir Pressure PositiveAir Pressure NegativeHoodsChemical Fume HoodLaminar Flow HoodBiological Safety CabinetSnorkelCanopy HoodOther:
Hand Washing SinkPLUMBING
Multiple Basin SinkFloor DrainFloor SinkSafety Shower/EyewashReverse Osmosis (RO)Carbon Dioxide (CO2)Nitrogen (N2)Oxygen (O2)Natural GasVacuumNitrous OxideCompressed Air
Suppression SystemFIRE SUPPRESSION/DETECTION
Fire ExtinguisherAlarm System Type:
Voice (Telephone)COMMUNICATIONS
Data (Computer)Data (Print/Scan/Fax)Cable TVCampus Closed Circuit TVNurse CallRFID/RTLSIntercomAssisted Listening
Speaker System - OverheadAUDIO/VISUAL
Presentation - DisplayPresentation - Projector/ScreenPresentation - LecternA/V Touch Control PanelAudio Conferencing
Lighting ControlDimmingAV Equipment in RoomAV Equipment in Comm RoomContent/Lecture RecordingOR Integration & ControlOR Scheduling & ManagementDVD/Blu-Ray PlayerDocument Camera
25
Video Conferencing
Special:ACOUSTICS
STP Wall: STP Floor:
Not Applicable
Electric Hardware Set
Volume II | Chapter I
Electrical Closet
REMARKS/NOTES:
26
1/4”=1’
Volume II | Chapter I
• (2) Single outlet wall roughin locations with (2) Cat6A cables• (1) Ceiling outlet roughin location with (2) Cat6A cables
• (1) Nurse call patient station and (1) staff terminal requiring a 3-gang outlet roughin each
• TV outlet location with (1) Cat6A cable• Overhead pagining speakers in adjacent area corridors
Prototypical Room Layout (140 Square Feet)
ACTUAL SIZE: 140 S.F.
Exam/Treatment Room
Room Data Sheet
8 Hours/DayUTILIZATION (HOURS OF USE)
14 Hours/Day24 Hours/Day
PowerELECTRICAL
WallWall Voice, Data, Video, MicFloor PowerFloor Voice, Data, Video, MicInstructor’s ConsoleLightingHouse, GeneralLinear Direct/Indirect FixturesTask LightingLighting ControlsDimmingEmergency Power
No LockSECURITY
Keyed LockCard AccessVideo Surveillance
FloorARCHITECTURAL
VCT (Chemical Resistance)VCTWelded Seam Sheet VinylEpoxyCarpetSealed ConcretePartitionsGyp Board, Epoxy PaintGyp Board, PaintVWCGlassOther: Curtain w/ TrackBase4” RubberIntegral w/ FloorOther:CeilingOpenAcoustical TileGyp BoardDoorWoodMetalVision PanelGlass
Standard Hardware SetDOOR HARDWARE
Automatic Door Operators
Temperature: 70-75F & 30-60% MECHANICAL
Heating & Cooling: Maintain 75FVentilation (Per Code)Acoustical Control15 Air Changes/Hour10 Air Changes/Hour6 Air Changes/Hour100% Make-up AirAir Pressure PositiveAir Pressure NegativeHoodsChemical Fume HoodLaminar Flow HoodBiological Safety CabinetSnorkelCanopy HoodOther:
Hand Washing SinkPLUMBING
Multiple Basin SinkFloor DrainFloor SinkSafety Shower/EyewashReverse Osmosis (RO)Carbon Dioxide (CO2)Nitrogen (N2)Oxygen (O2)Natural GasVacuumNitrous OxideCompressed Air
Suppression SystemFIRE SUPPRESSION/DETECTION
Fire ExtinguisherAlarm System Type:
Voice (Telephone)COMMUNICATIONS
Data (Computer)Data (Print/Scan/Fax)Cable TVCampus Closed Circuit TVNurse CallRFID/RTLSIntercomAssisted Listening
Speaker System - OverheadAUDIO/VISUAL
Presentation - DisplayPresentation - Projector/ScreenPresentation - LecternA/V Touch Control PanelAudio Conferencing
Lighting ControlDimmingAV Equipment in RoomAV Equipment in Comm RoomContent/Lecture RecordingOR Integration & ControlOR Scheduling & ManagementDVD/Blu-Ray PlayerDocument Camera
27
Video Conferencing
Special:ACOUSTICS
STP Wall: STP Floor:
See Appendix Table 1See Appendix Table 1
Electric Hardware Set
Volume II | Chapter I
Exam/Treatment Room
28 Volume II | Chapter I
REMARKS/NOTES:
3/16”=1’
• (8) Single outlet wall roughin locations with (2) Cat6A cables• (1) Ceiling outlet roughin with (4) Cat6A cables• (1) Wall Phones with (1) Cat6A cable
• OR integration system with (4) overhead speakers, (2) cameras, and (2) in-field displays• OR control & management touchscreen wall mounted with (1) Cat6A cable
• (1) Single outlet wall roughin location with (1) RTLS Cat6A cable• (2) Nurse call patient stations requiring a 3-gang outlet roughin• Overhead paging speakers in adjacent area corridors
ACTUAL SIZE: 320 S.F.
Prototypical Room Layout (320 Square Feet)
GI Endoscopy Lab
Room Data Sheet
8 Hours/DayUTILIZATION (HOURS OF USE)
14 Hours/Day24 Hours/Day
PowerELECTRICAL
WallWall Voice, Data, Video, MicFloor PowerFloor Voice, Data, Video, MicInstructor’s ConsoleLightingHouse, GeneralLinear Direct/Indirect FixturesTask LightingLighting ControlsDimmingEmergency Power
No LockSECURITY
Keyed LockCard AccessVideo Surveillance
FloorARCHITECTURAL
VCT (Chemical Resistance)VCTWelded Seam Sheet VinylEpoxyCarpetSealed ConcretePartitionsGyp Board, Epoxy PaintGyp Board, PaintVWCGlassOther: Curtain w/ TrackBase4” RubberIntegral w/ FloorOther:CeilingOpenAcoustical TileGyp BoardDoorWoodMetalVision PanelGlass
Standard Hardware SetDOOR HARDWARE
Automatic Door Operators
Temperature: 70-75F & 30-60% MECHANICAL
Heating & Cooling: Maintain 75FVentilation (Per Code)Acoustical Control15 Air Changes/Hour10 Air Changes/Hour6 Air Changes/Hour100% Make-up AirAir Pressure PositiveAir Pressure NegativeHoodsChemical Fume HoodLaminar Flow HoodBiological Safety CabinetSnorkelCanopy HoodOther:
Hand Washing SinkPLUMBING
Multiple Basin SinkFloor DrainFloor SinkSafety Shower/EyewashReverse Osmosis (RO)Carbon Dioxide (CO2)Nitrogen (N2)Oxygen (O2)Natural GasVacuumNitrous OxideCompressed Air
Suppression SystemFIRE SUPPRESSION/DETECTION
Fire ExtinguisherAlarm System Type:
Voice (Telephone)COMMUNICATIONS
Data (Computer)Data (Print/Scan/Fax)Cable TVCampus Closed Circuit TVNurse CallRFID/RTLSIntercomAssisted Listening
Speaker System - OverheadAUDIO/VISUAL
Presentation - DisplayPresentation - Projector/ScreenPresentation - LecternA/V Touch Control PanelAudio Conferencing
Lighting ControlDimmingAV Equipment in RoomAV Equipment in Comm RoomContent/Lecture RecordingOR Integration & ControlOR Scheduling & ManagementDVD/Blu-Ray PlayerDocument Camera
29
Video Conferencing
Special:ACOUSTICS
STP Wall: STP Floor:
See Appendix Table 1See Appendix Table 1
Electric Hardware Set
Volume II | Chapter I
GI Endoscopy Lab
REMARKS/NOTES:
30
1/4”=1’
Volume II | Chapter I
• (1) Wall phone with (1) Cat6A cable• Card reader with EVS and Facility access
ACTUAL SIZE: 50 S.F.
Prototypical Room Layout (50 Square Feet)
Housekeeping
Room Data Sheet
8 Hours/DayUTILIZATION (HOURS OF USE)
14 Hours/Day24 Hours/Day
PowerELECTRICAL
WallWall Voice, Data, Video, MicFloor PowerFloor Voice, Data, Video, MicInstructor’s ConsoleLightingHouse, GeneralLinear Direct/Indirect FixturesTask LightingLighting ControlsDimmingEmergency Power
No LockSECURITY
Keyed LockCard AccessVideo Surveillance
FloorARCHITECTURAL
VCT (Chemical Resistance)VCTWelded Seam Sheet VinylEpoxyCarpetSealed ConcretePartitionsGyp Board, Epoxy PaintGyp Board, PaintVWCGlassOther: Curtain w/ TrackBase4” RubberIntegral w/ FloorOther:CeilingOpenAcoustical TileGyp BoardDoorWoodMetalVision PanelGlass
Standard Hardware SetDOOR HARDWARE
Automatic Door Operators
Temperature: 70-75F & 30-60% MECHANICAL
Heating & Cooling: Maintain 75FVentilation (Per Code)Acoustical Control15 Air Changes/Hour10 Air Changes/Hour6 Air Changes/Hour100% Make-up AirAir Pressure PositiveAir Pressure NegativeHoodsChemical Fume HoodLaminar Flow HoodBiological Safety CabinetSnorkelCanopy HoodOther:
Hand Washing SinkPLUMBING
Multiple Basin SinkFloor DrainFloor SinkSafety Shower/EyewashReverse Osmosis (RO)Carbon Dioxide (CO2)Nitrogen (N2)Oxygen (O2)Natural GasVacuumNitrous OxideCompressed Air
Suppression SystemFIRE SUPPRESSION/DETECTION
Fire ExtinguisherAlarm System Type:
Voice (Telephone)COMMUNICATIONS
Data (Computer)Data (Print/Scan/Fax)Cable TVCampus Closed Circuit TVNurse CallRFID/RTLSIntercomAssisted Listening
Speaker System - OverheadAUDIO/VISUAL
Presentation - DisplayPresentation - Projector/ScreenPresentation - LecternA/V Touch Control PanelAudio Conferencing
Lighting ControlDimmingAV Equipment in RoomAV Equipment in Comm RoomContent/Lecture RecordingOR Integration & ControlOR Scheduling & ManagementDVD/Blu-Ray PlayerDocument Camera
31
Video Conferencing
Special:ACOUSTICS
STP Wall: STP Floor:
Electric Hardware Set
Volume II | Chapter I
Not Applicable
Housekeeping
REMARKS/NOTES:
32
1/4”=1’
Volume II | Chapter I
• (1) Wall phone with (1) Cat6A cable• Card reader with IT and BioMed access
ACTUAL SIZE: 200 S.F.
Prototypical Room Layout (200 Square Feet)
Intermediate Distribution Frame
Room Data Sheet
8 Hours/DayUTILIZATION (HOURS OF USE)
14 Hours/Day24 Hours/Day
PowerELECTRICAL
WallWall Voice, Data, Video, MicFloor PowerFloor Voice, Data, Video, MicInstructor’s ConsoleLightingHouse, GeneralLinear Direct/Indirect FixturesTask LightingLighting ControlsDimmingEmergency Power
No LockSECURITY
Keyed LockCard AccessVideo Surveillance
FloorARCHITECTURAL
VCT (Chemical Resistance)VCTWelded Seam Sheet VinylEpoxyCarpetSealed ConcretePartitionsGyp Board, Epoxy PaintGyp Board, PaintVWCGlassOther: Curtain w/ TrackBase4” RubberIntegral w/ FloorOther:CeilingOpenAcoustical TileGyp BoardDoorWoodMetalVision PanelGlass
Standard Hardware SetDOOR HARDWARE
Automatic Door Operators
Temperature: 70-75F & 30-60% MECHANICAL
Heating & Cooling: Maintain 75FVentilation (Per Code)Acoustical Control15 Air Changes/Hour10 Air Changes/Hour6 Air Changes/Hour100% Make-up AirAir Pressure PositiveAir Pressure NegativeHoodsChemical Fume HoodLaminar Flow HoodBiological Safety CabinetSnorkelCanopy HoodOther:
Hand Washing SinkPLUMBING
Multiple Basin SinkFloor DrainFloor SinkSafety Shower/EyewashReverse Osmosis (RO)Carbon Dioxide (CO2)Nitrogen (N2)Oxygen (O2)Natural GasVacuumNitrous OxideCompressed Air
Suppression SystemFIRE SUPPRESSION/DETECTION
Fire ExtinguisherAlarm System Type:
Voice (Telephone)COMMUNICATIONS
Data (Computer)Data (Print/Scan/Fax)Cable TVCampus Closed Circuit TVNurse CallRFID/RTLSIntercomAssisted Listening
Speaker System - OverheadAUDIO/VISUAL
Presentation - DisplayPresentation - Projector/ScreenPresentation - LecternA/V Touch Control PanelAudio Conferencing
Lighting ControlDimmingAV Equipment in RoomAV Equipment in Comm RoomContent/Lecture RecordingOR Integration & ControlOR Scheduling & ManagementDVD/Blu-Ray PlayerDocument Camera
33
Video Conferencing
Special:ACOUSTICS
STP Wall: STP Floor:
Not Applicable
Electric Hardware Set
Volume II | Chapter I
Intermediate Distribution Frame
34 Volume II | Chapter I
REMARKS/NOTES:• (4) Single outlet wall roughin location with (2) Cat6A cables• (1) Ceiling outlet roughin location with (2) Cat6A cables
• (2) Nurse call patient station requiring a 3-gang outlet roughin• Nurse call pull cord with audio in bathroom
• TV outlet location with (1) Cat6A cable• Interactive content/Patient portal• Overhead Paging speakers in adjacent area corridors
3/16”=1’
Prototypical Room Layout (428 Square Feet)
ACTUAL SIZE: 308 S.F.EQUIPMENT: 56 S.F.
TOILET: 64 S.F.
Labor/Delivery/Recovery Room
Room Data Sheet
8 Hours/DayUTILIZATION (HOURS OF USE)
14 Hours/Day24 Hours/Day
PowerELECTRICAL
WallWall Voice, Data, Video, MicFloor PowerFloor Voice, Data, Video, MicInstructor’s ConsoleLightingHouse, GeneralLinear Direct/Indirect FixturesTask LightingLighting ControlsDimmingEmergency Power
No LockSECURITY
Keyed LockCard AccessVideo Surveillance
FloorARCHITECTURAL
VCT (Chemical Resistance)VCTWelded Seam Sheet VinylEpoxyCarpetSealed ConcretePartitionsGyp Board, Epoxy PaintGyp Board, PaintVWCGlassOther: Curtain w/ TrackBase4” RubberIntegral w/ FloorOther:CeilingOpenAcoustical TileGyp BoardDoorWoodMetalVision PanelGlass
Standard Hardware SetDOOR HARDWARE
Automatic Door Operators
Temperature: 70-75F & 30-60% MECHANICAL
Heating & Cooling: Maintain 75FVentilation (Per Code)Acoustical Control15 Air Changes/Hour10 Air Changes/Hour6 Air Changes/Hour100% Make-up AirAir Pressure PositiveAir Pressure NegativeHoodsChemical Fume HoodLaminar Flow HoodBiological Safety CabinetSnorkelCanopy HoodOther:
Hand Washing SinkPLUMBING
Multiple Basin SinkFloor DrainFloor SinkSafety Shower/EyewashReverse Osmosis (RO)Carbon Dioxide (CO2)Nitrogen (N2)Oxygen (O2)Natural GasVacuumNitrous OxideCompressed Air
Suppression SystemFIRE SUPPRESSION/DETECTION
Fire ExtinguisherAlarm System Type:
Voice (Telephone)COMMUNICATIONS
Data (Computer)Data (Print/Scan/Fax)Cable TVCampus Closed Circuit TVNurse CallRFID/RTLSIntercomAssisted Listening
Speaker System - OverheadAUDIO/VISUAL
Presentation - DisplayPresentation - Projector/ScreenPresentation - LecternA/V Touch Control PanelAudio Conferencing
Lighting ControlDimmingAV Equipment in RoomAV Equipment in Comm RoomContent/Lecture RecordingOR Integration & ControlOR Scheduling & ManagementDVD/Blu-Ray PlayerDocument Camera
35
Video Conferencing
Special:ACOUSTICS
STP Wall: STP Floor:
See Appendix Table 1See Appendix Table 1
Electric Hardware Set
Volume II | Chapter I
Labor/Delivery/Recovery Room
REMARKS/NOTES:
36 Volume II | Chapter I
• (2) Wall phone with (1) Cat6A cable each• Card reader with IT and BioMed access
1/8”=1’ ACTUAL SIZE: 720 S.F.
Prototypical Room Layout (720 Square Feet)
Main Distribution Frame
Room Data Sheet
8 Hours/DayUTILIZATION (HOURS OF USE)
14 Hours/Day24 Hours/Day
PowerELECTRICAL
WallWall Voice, Data, Video, MicFloor PowerFloor Voice, Data, Video, MicInstructor’s ConsoleLightingHouse, GeneralLinear Direct/Indirect FixturesTask LightingLighting ControlsDimmingEmergency Power
No LockSECURITY
Keyed LockCard AccessVideo Surveillance
FloorARCHITECTURAL
VCT (Chemical Resistance)VCTWelded Seam Sheet VinylEpoxyCarpetSealed ConcretePartitionsGyp Board, Epoxy PaintGyp Board, PaintVWCGlassOther: Curtain w/ TrackBase4” RubberIntegral w/ FloorOther:CeilingOpenAcoustical TileGyp BoardDoorWoodMetalVision PanelGlass
Standard Hardware SetDOOR HARDWARE
Automatic Door Operators
Temperature: 70-75F & 30-60% MECHANICAL
Heating & Cooling: Maintain 75FVentilation (Per Code)Acoustical Control15 Air Changes/Hour10 Air Changes/Hour6 Air Changes/Hour100% Make-up AirAir Pressure PositiveAir Pressure NegativeHoodsChemical Fume HoodLaminar Flow HoodBiological Safety CabinetSnorkelCanopy HoodOther:
Hand Washing SinkPLUMBING
Multiple Basin SinkFloor DrainFloor SinkSafety Shower/EyewashReverse Osmosis (RO)Carbon Dioxide (CO2)Nitrogen (N2)Oxygen (O2)Natural GasVacuumNitrous OxideCompressed Air
Suppression SystemFIRE SUPPRESSION/DETECTION
Fire ExtinguisherAlarm System Type:
Voice (Telephone)COMMUNICATIONS
Data (Computer)Data (Print/Scan/Fax)Cable TVCampus Closed Circuit TVNurse CallRFID/RTLSIntercomAssisted Listening
Speaker System - OverheadAUDIO/VISUAL
Presentation - DisplayPresentation - Projector/ScreenPresentation - LecternA/V Touch Control PanelAudio Conferencing
Lighting ControlDimmingAV Equipment in RoomAV Equipment in Comm RoomContent/Lecture RecordingOR Integration & ControlOR Scheduling & ManagementDVD/Blu-Ray PlayerDocument Camera
37
Video Conferencing
Special:ACOUSTICS
STP Wall: STP Floor:
Not Applicable
Electric Hardware Set
Volume II | Chapter I
Main Distribution Frame
REMARKS/NOTES:
38
1/4”=1’
Volume II | Chapter I
• Card reader with Clinical Staff access• (2) Single outlet wall roughin location with (2) Cat6A ables
• Nurse call duty station requiring a single outlet roughin• Security camera with (1) ceiling (1) Cat6A cable
• (1) Wall Phones with (1) Cat6A cable• Overhead paging speakers in adjacent area corridors and room
ACTUAL SIZE: 100 S.F.
Prototypical Room Layout (100 Square Feet)
Medication
Room Data Sheet
8 Hours/DayUTILIZATION (HOURS OF USE)
14 Hours/Day24 Hours/Day
PowerELECTRICAL
WallWall Voice, Data, Video, MicFloor PowerFloor Voice, Data, Video, MicInstructor’s ConsoleLightingHouse, GeneralLinear Direct/Indirect FixturesTask LightingLighting ControlsDimmingEmergency Power
No LockSECURITY
Keyed LockCard AccessVideo Surveillance
FloorARCHITECTURAL
VCT (Chemical Resistance)VCTWelded Seam Sheet VinylEpoxyCarpetSealed ConcretePartitionsGyp Board, Epoxy PaintGyp Board, PaintVWCGlassOther: Curtain w/ TrackBase4” RubberIntegral w/ FloorOther:CeilingOpenAcoustical TileGyp BoardDoorWoodMetalVision PanelGlass
Standard Hardware SetDOOR HARDWARE
Automatic Door Operators
Temperature: 70-75F & 30-60% MECHANICAL
Heating & Cooling: Maintain 75FVentilation (Per Code)Acoustical Control15 Air Changes/Hour10 Air Changes/Hour6 Air Changes/Hour100% Make-up AirAir Pressure PositiveAir Pressure NegativeHoodsChemical Fume HoodLaminar Flow HoodBiological Safety CabinetSnorkelCanopy HoodOther:
Hand Washing SinkPLUMBING
Multiple Basin SinkFloor DrainFloor SinkSafety Shower/EyewashReverse Osmosis (RO)Carbon Dioxide (CO2)Nitrogen (N2)Oxygen (O2)Natural GasVacuumNitrous OxideCompressed Air
Suppression SystemFIRE SUPPRESSION/DETECTION
Fire ExtinguisherAlarm System Type:
Voice (Telephone)COMMUNICATIONS
Data (Computer)Data (Print/Scan/Fax)Cable TVCampus Closed Circuit TVNurse CallRFID/RTLSIntercomAssisted Listening
Speaker System - OverheadAUDIO/VISUAL
Presentation - DisplayPresentation - Projector/ScreenPresentation - LecternA/V Touch Control PanelAudio Conferencing
Lighting ControlDimmingAV Equipment in RoomAV Equipment in Comm RoomContent/Lecture RecordingOR Integration & ControlOR Scheduling & ManagementDVD/Blu-Ray PlayerDocument Camera
39
Video Conferencing
Special:ACOUSTICS
STP Wall: STP Floor:
Not Applicable
Electric Hardware Set
Volume II | Chapter I
Medication
REMARKS/NOTES:
40
1/4”=1’
Volume II | Chapter I
• (4) Single outlet wall roughin location with (2) Cat6A cables• TV outlet location with (1) Cat6A cable
• Overhead pagining speakers in adjacent area corridors• (1) RTLS ceiling mount at room door
• (1) Nurse call patient station and (1) staff terminal requiring a 3-gang outlet rouhin each
ACTUAL SIZE: 200 S.F.
Prototypical Room Layout (200 Square Feet)
NICU
Room Data Sheet
8 Hours/DayUTILIZATION (HOURS OF USE)
14 Hours/Day24 Hours/Day
PowerELECTRICAL
WallWall Voice, Data, Video, MicFloor PowerFloor Voice, Data, Video, MicInstructor’s ConsoleLightingHouse, GeneralLinear Direct/Indirect FixturesTask LightingLighting ControlsDimmingEmergency Power
No LockSECURITY
Keyed LockCard AccessVideo Surveillance
FloorARCHITECTURAL
VCT (Chemical Resistance)VCTWelded Seam Sheet VinylEpoxyCarpetSealed ConcretePartitionsGyp Board, Epoxy PaintGyp Board, PaintVWCGlassOther: Curtain w/ TrackBase4” RubberIntegral w/ FloorOther:CeilingOpenAcoustical TileGyp BoardDoorWoodMetalVision PanelGlass
Standard Hardware SetDOOR HARDWARE
Automatic Door Operators
Temperature: 70-75F & 30-60% MECHANICAL
Heating & Cooling: Maintain 75FVentilation (Per Code)Acoustical Control15 Air Changes/Hour10 Air Changes/Hour6 Air Changes/Hour100% Make-up AirAir Pressure PositiveAir Pressure NegativeHoodsChemical Fume HoodLaminar Flow HoodBiological Safety CabinetSnorkelCanopy HoodOther:
Hand Washing SinkPLUMBING
Multiple Basin SinkFloor DrainFloor SinkSafety Shower/EyewashReverse Osmosis (RO)Carbon Dioxide (CO2)Nitrogen (N2)Oxygen (O2)Natural GasVacuumNitrous OxideCompressed Air
Suppression SystemFIRE SUPPRESSION/DETECTION
Fire ExtinguisherAlarm System Type:
Voice (Telephone)COMMUNICATIONS
Data (Computer)Data (Print/Scan/Fax)Cable TVCampus Closed Circuit TVNurse CallRFID/RTLSIntercomAssisted Listening
Speaker System - OverheadAUDIO/VISUAL
Presentation - DisplayPresentation - Projector/ScreenPresentation - LecternA/V Touch Control PanelAudio Conferencing
Lighting ControlDimmingAV Equipment in RoomAV Equipment in Comm RoomContent/Lecture RecordingOR Integration & ControlOR Scheduling & ManagementDVD/Blu-Ray PlayerDocument Camera
41
Video Conferencing
Special:ACOUSTICS
STP Wall: STP Floor:
See Appendix Table 1See Appendix Table 1
Electric Hardware Set
Volume II | Chapter I
NICU
REMARKS/NOTES:
42
1/4”=1’
Volume II | Chapter I
• Card reader with Clinical Staff access• (1) Single outlet wall roughin location with (2) Cat6A cables
• Overhead pagining speakers in adjacent area corridors and room• Nurse call duty station requiring a single outlet roughin
ACTUAL SIZE: 110 S.F.
Prototypical Room Layout (110 Square Feet)
Nourishment
Room Data Sheet
8 Hours/DayUTILIZATION (HOURS OF USE)
14 Hours/Day24 Hours/Day
PowerELECTRICAL
WallWall Voice, Data, Video, MicFloor PowerFloor Voice, Data, Video, MicInstructor’s ConsoleLightingHouse, GeneralLinear Direct/Indirect FixturesTask LightingLighting ControlsDimmingEmergency Power
No LockSECURITY
Keyed LockCard AccessVideo Surveillance
FloorARCHITECTURAL
VCT (Chemical Resistance)VCTWelded Seam Sheet VinylEpoxyCarpetSealed ConcretePartitionsGyp Board, Epoxy PaintGyp Board, PaintVWCGlassOther: Curtain w/ TrackBase4” RubberIntegral w/ FloorOther:CeilingOpenAcoustical TileGyp BoardDoorWoodMetalVision PanelGlass
Standard Hardware SetDOOR HARDWARE
Automatic Door Operators
Temperature: 70-75F & 30-60% MECHANICAL
Heating & Cooling: Maintain 75FVentilation (Per Code)Acoustical Control15 Air Changes/Hour10 Air Changes/Hour6 Air Changes/Hour100% Make-up AirAir Pressure PositiveAir Pressure NegativeHoodsChemical Fume HoodLaminar Flow HoodBiological Safety CabinetSnorkelCanopy HoodOther:
Hand Washing SinkPLUMBING
Multiple Basin SinkFloor DrainFloor SinkSafety Shower/EyewashReverse Osmosis (RO)Carbon Dioxide (CO2)Nitrogen (N2)Oxygen (O2)Natural GasVacuumNitrous OxideCompressed Air
Suppression SystemFIRE SUPPRESSION/DETECTION
Fire ExtinguisherAlarm System Type:
Voice (Telephone)COMMUNICATIONS
Data (Computer)Data (Print/Scan/Fax)Cable TVCampus Closed Circuit TVNurse CallRFID/RTLSIntercomAssisted Listening
Speaker System - OverheadAUDIO/VISUAL
Presentation - DisplayPresentation - Projector/ScreenPresentation - LecternA/V Touch Control PanelAudio Conferencing
Lighting ControlDimmingAV Equipment in RoomAV Equipment in Comm RoomContent/Lecture RecordingOR Integration & ControlOR Scheduling & ManagementDVD/Blu-Ray PlayerDocument Camera
43
Video Conferencing
Special:ACOUSTICS
STP Wall: STP Floor:
Not Applicable
Electric Hardware Set
Volume II | Chapter I
Nourishment
REMARKS/NOTES:
44
1/4”=1’
Volume II | Chapter I
• Card reader with Clinical Staff access• (4) Single outlet wall roughin location with (4) Cat6A cables
• Security duress buttom with (1) single roughin• If P-Tube located here add (1) Cat6A at location
• Overhead pagining speakers in adjacent area corridors and room• Nurse call console station requiring a single outlet roughin
ACTUAL SIZE: 200 S.F.
Prototypical Room Layout (200 Square Feet)
Nurse Station
Room Data Sheet
8 Hours/DayUTILIZATION (HOURS OF USE)
14 Hours/Day24 Hours/Day
PowerELECTRICAL
WallWall Voice, Data, Video, MicFloor PowerFloor Voice, Data, Video, MicInstructor’s ConsoleLightingHouse, GeneralLinear Direct/Indirect FixturesTask LightingLighting ControlsDimmingEmergency Power
No LockSECURITY
Keyed LockCard AccessVideo Surveillance
FloorARCHITECTURAL
VCT (Chemical Resistance)VCTWelded Seam Sheet VinylEpoxyCarpetSealed ConcretePartitionsGyp Board, Epoxy PaintGyp Board, PaintVWCGlassOther: Curtain w/ TrackBase4” RubberIntegral w/ FloorOther:CeilingOpenAcoustical TileGyp BoardDoorWoodMetalVision PanelGlass
Standard Hardware SetDOOR HARDWARE
Automatic Door Operators
Temperature: 70-75F & 30-60% MECHANICAL
Heating & Cooling: Maintain 75FVentilation (Per Code)Acoustical Control15 Air Changes/Hour10 Air Changes/Hour6 Air Changes/Hour100% Make-up AirAir Pressure PositiveAir Pressure NegativeHoodsChemical Fume HoodLaminar Flow HoodBiological Safety CabinetSnorkelCanopy HoodOther:
Hand Washing SinkPLUMBING
Multiple Basin SinkFloor DrainFloor SinkSafety Shower/EyewashReverse Osmosis (RO)Carbon Dioxide (CO2)Nitrogen (N2)Oxygen (O2)Natural GasVacuumNitrous OxideCompressed Air
Suppression SystemFIRE SUPPRESSION/DETECTION
Fire ExtinguisherAlarm System Type:
Voice (Telephone)COMMUNICATIONS
Data (Computer)Data (Print/Scan/Fax)Cable TVCampus Closed Circuit TVNurse CallRFID/RTLSIntercomAssisted Listening
Speaker System - OverheadAUDIO/VISUAL
Presentation - DisplayPresentation - Projector/ScreenPresentation - LecternA/V Touch Control PanelAudio Conferencing
Lighting ControlDimmingAV Equipment in RoomAV Equipment in Comm RoomContent/Lecture RecordingOR Integration & ControlOR Scheduling & ManagementDVD/Blu-Ray PlayerDocument Camera
45
Video Conferencing
Special:ACOUSTICS
STP Wall: STP Floor:
Not Applicable
Electric Hardware Set
Volume II | Chapter I
Nurse Station
REMARKS/NOTES:
46
1/4”=1’
Volume II | Chapter I
• (2) Single outlet wall roughin location with (2) Cat6A cables
ACTUAL SIZE: 100 S.F.
Prototypical Room Layout (100 Square Feet)
Offices - Manager/Director
Room Data Sheet
8 Hours/DayUTILIZATION (HOURS OF USE)
14 Hours/Day24 Hours/Day
PowerELECTRICAL
WallWall Voice, Data, Video, MicFloor PowerFloor Voice, Data, Video, MicInstructor’s ConsoleLightingHouse, GeneralLinear Direct/Indirect FixturesTask LightingLighting ControlsDimmingEmergency Power
No LockSECURITY
Keyed LockCard AccessVideo Surveillance
FloorARCHITECTURAL
VCT (Chemical Resistance)VCTWelded Seam Sheet VinylEpoxyCarpetSealed ConcretePartitionsGyp Board, Epoxy PaintGyp Board, PaintVWCGlassOther: Curtain w/ TrackBase4” RubberIntegral w/ FloorOther:CeilingOpenAcoustical TileGyp BoardDoorWoodMetalVision PanelGlass
Standard Hardware SetDOOR HARDWARE
Automatic Door Operators
Temperature: 70-75F & 30-60% MECHANICAL
Heating & Cooling: Maintain 75FVentilation (Per Code)Acoustical Control15 Air Changes/Hour10 Air Changes/Hour6 Air Changes/Hour100% Make-up AirAir Pressure PositiveAir Pressure NegativeHoodsChemical Fume HoodLaminar Flow HoodBiological Safety CabinetSnorkelCanopy HoodOther:
Hand Washing SinkPLUMBING
Multiple Basin SinkFloor DrainFloor SinkSafety Shower/EyewashReverse Osmosis (RO)Carbon Dioxide (CO2)Nitrogen (N2)Oxygen (O2)Natural GasVacuumNitrous OxideCompressed Air
Suppression SystemFIRE SUPPRESSION/DETECTION
Fire ExtinguisherAlarm System Type:
Voice (Telephone)COMMUNICATIONS
Data (Computer)Data (Print/Scan/Fax)Cable TVCampus Closed Circuit TVNurse CallRFID/RTLSIntercomAssisted Listening
Speaker System - OverheadAUDIO/VISUAL
Presentation - DisplayPresentation - Projector/ScreenPresentation - LecternA/V Touch Control PanelAudio Conferencing
Lighting ControlDimmingAV Equipment in RoomAV Equipment in Comm RoomContent/Lecture RecordingOR Integration & ControlOR Scheduling & ManagementDVD/Blu-Ray PlayerDocument Camera
47
Video Conferencing
ACOUSTICS
Electric Hardware Set
Volume II | Chapter I
Offices - Manager/Director
Special: Walls to Deck with
Located in WallsSound Batt Insulation
REMARKS/NOTES:
48
1/4”=1’
Volume II | Chapter I
• (2) Single outlet wall roughin location with (2) Cat6A cables
ACTUAL SIZE: 180 S.F.
Prototypical Room Layout (180 Square Feet)
Offices - Vice President
Room Data Sheet
8 Hours/DayUTILIZATION (HOURS OF USE)
14 Hours/Day24 Hours/Day
PowerELECTRICAL
WallWall Voice, Data, Video, MicFloor PowerFloor Voice, Data, Video, MicInstructor’s ConsoleLightingHouse, GeneralLinear Direct/Indirect FixturesTask LightingLighting ControlsDimmingEmergency Power
No LockSECURITY
Keyed LockCard AccessVideo Surveillance
FloorARCHITECTURAL
VCT (Chemical Resistance)VCTWelded Seam Sheet VinylEpoxyCarpetSealed ConcretePartitionsGyp Board, Epoxy PaintGyp Board, PaintVWCGlassOther: Curtain w/ TrackBase4” RubberIntegral w/ FloorOther:CeilingOpenAcoustical TileGyp BoardDoorWoodMetalVision PanelGlass
Standard Hardware SetDOOR HARDWARE
Automatic Door Operators
Temperature: 70-75F & 30-60% MECHANICAL
Heating & Cooling: Maintain 75FVentilation (Per Code)Acoustical Control15 Air Changes/Hour10 Air Changes/Hour6 Air Changes/Hour100% Make-up AirAir Pressure PositiveAir Pressure NegativeHoodsChemical Fume HoodLaminar Flow HoodBiological Safety CabinetSnorkelCanopy HoodOther:
Hand Washing SinkPLUMBING
Multiple Basin SinkFloor DrainFloor SinkSafety Shower/EyewashReverse Osmosis (RO)Carbon Dioxide (CO2)Nitrogen (N2)Oxygen (O2)Natural GasVacuumNitrous OxideCompressed Air
Suppression SystemFIRE SUPPRESSION/DETECTION
Fire ExtinguisherAlarm System Type:
Voice (Telephone)COMMUNICATIONS
Data (Computer)Data (Print/Scan/Fax)Cable TVCampus Closed Circuit TVNurse CallRFID/RTLSIntercomAssisted Listening
Speaker System - OverheadAUDIO/VISUAL
Presentation - DisplayPresentation - Projector/ScreenPresentation - LecternA/V Touch Control PanelAudio Conferencing
Lighting ControlDimmingAV Equipment in RoomAV Equipment in Comm RoomContent/Lecture RecordingOR Integration & ControlOR Scheduling & ManagementDVD/Blu-Ray PlayerDocument Camera
49
Video Conferencing
ACOUSTICS
Electric Hardware Set
Volume II | Chapter I
Offices - Vice President
Special: Walls to Deck with
Located in WallsSound Batt Insulation
REMARKS/NOTES:
50
1/4”=1’
Volume II | Chapter I
ACTUAL SIZE: 33 S.F.
Prototypical Room Layout (33 Square Feet)
• Modular furniture system• (2) Single outlet wall roughin location with (2) Cat6A cables
Offices - Single Open Workstation
Room Data Sheet
8 Hours/DayUTILIZATION (HOURS OF USE)
14 Hours/Day24 Hours/Day
PowerELECTRICAL
WallWall Voice, Data, Video, MicFloor PowerFloor Voice, Data, Video, MicInstructor’s ConsoleLightingHouse, GeneralLinear Direct/Indirect FixturesTask LightingLighting ControlsDimmingEmergency Power
No LockSECURITY
Keyed LockCard AccessVideo Surveillance
FloorARCHITECTURAL
VCT (Chemical Resistance)VCTWelded Seam Sheet VinylEpoxyCarpetSealed ConcretePartitionsGyp Board, Epoxy PaintGyp Board, PaintVWCGlassOther: Curtain w/ TrackBase4” RubberIntegral w/ FloorOther:CeilingOpenAcoustical TileGyp BoardDoorWoodMetalVision PanelGlass
Standard Hardware SetDOOR HARDWARE
Automatic Door Operators
Temperature: 70-75F & 30-60% MECHANICAL
Heating & Cooling: Maintain 75FVentilation (Per Code)Acoustical Control15 Air Changes/Hour10 Air Changes/Hour6 Air Changes/Hour100% Make-up AirAir Pressure PositiveAir Pressure NegativeHoodsChemical Fume HoodLaminar Flow HoodBiological Safety CabinetSnorkelCanopy HoodOther:
Hand Washing SinkPLUMBING
Multiple Basin SinkFloor DrainFloor SinkSafety Shower/EyewashReverse Osmosis (RO)Carbon Dioxide (CO2)Nitrogen (N2)Oxygen (O2)Natural GasVacuumNitrous OxideCompressed Air
Suppression SystemFIRE SUPPRESSION/DETECTION
Fire ExtinguisherAlarm System Type:
Voice (Telephone)COMMUNICATIONS
Data (Computer)Data (Print/Scan/Fax)Cable TVCampus Closed Circuit TVNurse CallRFID/RTLSIntercomAssisted Listening
Speaker System - OverheadAUDIO/VISUAL
Presentation - DisplayPresentation - Projector/ScreenPresentation - LecternA/V Touch Control PanelAudio Conferencing
Lighting ControlDimmingAV Equipment in RoomAV Equipment in Comm RoomContent/Lecture RecordingOR Integration & ControlOR Scheduling & ManagementDVD/Blu-Ray PlayerDocument Camera
51
Video Conferencing
Special:ACOUSTICS
STP Wall: STP Floor:
Not Applicable
Electric Hardware Set
Volume II | Chapter I
Offices - Single Open Workstation
REMARKS/NOTES:
52
1/4”=1’
Volume II | Chapter I
• (3) Single outlet wall roughin location with (2) Cat6A cables
ACTUAL SIZE: 120 S.F.
Prototypical Room Layout (120 Square Feet)
Offices - Three-person Shared
Room Data Sheet
8 Hours/DayUTILIZATION (HOURS OF USE)
14 Hours/Day24 Hours/Day
PowerELECTRICAL
WallWall Voice, Data, Video, MicFloor PowerFloor Voice, Data, Video, MicInstructor’s ConsoleLightingHouse, GeneralLinear Direct/Indirect FixturesTask LightingLighting ControlsDimmingEmergency Power
No LockSECURITY
Keyed LockCard AccessVideo Surveillance
FloorARCHITECTURAL
VCT (Chemical Resistance)VCTWelded Seam Sheet VinylEpoxyCarpetSealed ConcretePartitionsGyp Board, Epoxy PaintGyp Board, PaintVWCGlassOther: Curtain w/ TrackBase4” RubberIntegral w/ FloorOther:CeilingOpenAcoustical TileGyp BoardDoorWoodMetalVision PanelGlass
Standard Hardware SetDOOR HARDWARE
Automatic Door Operators
Temperature: 70-75F & 30-60% MECHANICAL
Heating & Cooling: Maintain 75FVentilation (Per Code)Acoustical Control15 Air Changes/Hour10 Air Changes/Hour6 Air Changes/Hour100% Make-up AirAir Pressure PositiveAir Pressure NegativeHoodsChemical Fume HoodLaminar Flow HoodBiological Safety CabinetSnorkelCanopy HoodOther:
Hand Washing SinkPLUMBING
Multiple Basin SinkFloor DrainFloor SinkSafety Shower/EyewashReverse Osmosis (RO)Carbon Dioxide (CO2)Nitrogen (N2)Oxygen (O2)Natural GasVacuumNitrous OxideCompressed Air
Suppression SystemFIRE SUPPRESSION/DETECTION
Fire ExtinguisherAlarm System Type:
Voice (Telephone)COMMUNICATIONS
Data (Computer)Data (Print/Scan/Fax)Cable TVCampus Closed Circuit TVNurse CallRFID/RTLSIntercomAssisted Listening
Speaker System - OverheadAUDIO/VISUAL
Presentation - DisplayPresentation - Projector/ScreenPresentation - LecternA/V Touch Control PanelAudio Conferencing
Lighting ControlDimmingAV Equipment in RoomAV Equipment in Comm RoomContent/Lecture RecordingOR Integration & ControlOR Scheduling & ManagementDVD/Blu-Ray PlayerDocument Camera
53
Video Conferencing
ACOUSTICS
Electric Hardware Set
Volume II | Chapter I
Offices - Three-person Shared
Special: Walls to Deck with
Located in WallsSound Batt Insulation
REMARKS/NOTES:
54
1/4”=1’
Volume II | Chapter I
• (2) Single outlet wall roughin location with (2) Cat6A cables
ACTUAL SIZE: 80 S.F.
Prototypical Room Layout (80 Square Feet)
Offices - Two-person Shared
Room Data Sheet
8 Hours/DayUTILIZATION (HOURS OF USE)
14 Hours/Day24 Hours/Day
PowerELECTRICAL
WallWall Voice, Data, Video, MicFloor PowerFloor Voice, Data, Video, MicInstructor’s ConsoleLightingHouse, GeneralLinear Direct/Indirect FixturesTask LightingLighting ControlsDimmingEmergency Power
No LockSECURITY
Keyed LockCard AccessVideo Surveillance
FloorARCHITECTURAL
VCT (Chemical Resistance)VCTWelded Seam Sheet VinylEpoxyCarpetSealed ConcretePartitionsGyp Board, Epoxy PaintGyp Board, PaintVWCGlassOther: Curtain w/ TrackBase4” RubberIntegral w/ FloorOther:CeilingOpenAcoustical TileGyp BoardDoorWoodMetalVision PanelGlass
Standard Hardware SetDOOR HARDWARE
Automatic Door Operators
Temperature: 70-75F & 30-60% MECHANICAL
Heating & Cooling: Maintain 75FVentilation (Per Code)Acoustical Control15 Air Changes/Hour10 Air Changes/Hour6 Air Changes/Hour100% Make-up AirAir Pressure PositiveAir Pressure NegativeHoodsChemical Fume HoodLaminar Flow HoodBiological Safety CabinetSnorkelCanopy HoodOther:
Hand Washing SinkPLUMBING
Multiple Basin SinkFloor DrainFloor SinkSafety Shower/EyewashReverse Osmosis (RO)Carbon Dioxide (CO2)Nitrogen (N2)Oxygen (O2)Natural GasVacuumNitrous OxideCompressed Air
Suppression SystemFIRE SUPPRESSION/DETECTION
Fire ExtinguisherAlarm System Type:
Voice (Telephone)COMMUNICATIONS
Data (Computer)Data (Print/Scan/Fax)Cable TVCampus Closed Circuit TVNurse CallRFID/RTLSIntercomAssisted Listening
Speaker System - OverheadAUDIO/VISUAL
Presentation - DisplayPresentation - Projector/ScreenPresentation - LecternA/V Touch Control PanelAudio Conferencing
Lighting ControlDimmingAV Equipment in RoomAV Equipment in Comm RoomContent/Lecture RecordingOR Integration & ControlOR Scheduling & ManagementDVD/Blu-Ray PlayerDocument Camera
55
Video Conferencing
ACOUSTICS
Electric Hardware Set
Volume II | Chapter I
Offices - Two-person Shared
Special: Walls to Deck with
Located in WallsSound Batt Insulation
REMARKS/NOTES:
56
1/4”=1’
Volume II | Chapter I
• (2) Single outlet wall roughin location with (2) Cat6A cables• Overhead pagining speakers in adjacent area corridors
• (1) Nurse patient station requiring a 3- gang outlet roughin• (1) Corridor light
ACTUAL SIZE: 140 S.F.
Prototypical Room Layout (140 Square Feet)
PACU Room
Room Data Sheet
8 Hours/DayUTILIZATION (HOURS OF USE)
14 Hours/Day24 Hours/Day
PowerELECTRICAL
WallWall Voice, Data, Video, MicFloor PowerFloor Voice, Data, Video, MicInstructor’s ConsoleLightingHouse, GeneralLinear Direct/Indirect FixturesTask LightingLighting ControlsDimmingEmergency Power
No LockSECURITY
Keyed LockCard AccessVideo Surveillance
FloorARCHITECTURAL
VCT (Chemical Resistance)VCTWelded Seam Sheet VinylEpoxyCarpetSealed ConcretePartitionsGyp Board, Epoxy PaintGyp Board, PaintVWCGlassOther: Curtain w/ TrackBase4” RubberIntegral w/ FloorOther:CeilingOpenAcoustical TileGyp BoardDoorWoodMetalVision PanelGlass
Standard Hardware SetDOOR HARDWARE
Automatic Door Operators
Temperature: 70-75F & 30-60% MECHANICAL
Heating & Cooling: Maintain 75FVentilation (Per Code)Acoustical Control15 Air Changes/Hour10 Air Changes/Hour6 Air Changes/Hour100% Make-up AirAir Pressure PositiveAir Pressure NegativeHoodsChemical Fume HoodLaminar Flow HoodBiological Safety CabinetSnorkelCanopy HoodOther:
Hand Washing SinkPLUMBING
Multiple Basin SinkFloor DrainFloor SinkSafety Shower/EyewashReverse Osmosis (RO)Carbon Dioxide (CO2)Nitrogen (N2)Oxygen (O2)Natural GasVacuumNitrous OxideCompressed Air
Suppression SystemFIRE SUPPRESSION/DETECTION
Fire ExtinguisherAlarm System Type:
Voice (Telephone)COMMUNICATIONS
Data (Computer)Data (Print/Scan/Fax)Cable TVCampus Closed Circuit TVNurse CallRFID/RTLSIntercomAssisted Listening
Speaker System - OverheadAUDIO/VISUAL
Presentation - DisplayPresentation - Projector/ScreenPresentation - LecternA/V Touch Control PanelAudio Conferencing
Lighting ControlDimmingAV Equipment in RoomAV Equipment in Comm RoomContent/Lecture RecordingOR Integration & ControlOR Scheduling & ManagementDVD/Blu-Ray PlayerDocument Camera
57
Video Conferencing
Special:ACOUSTICS
STP Wall: STP Floor:
See Appendix Table 1See Appendix Table 1
Electric Hardware Set
Volume II | Chapter I
PACU Room
REMARKS/NOTES:
58 Volume II | Chapter I
• (3) Single outlet wall roughin location with (2) Cat6A cables• TV outlet location with (1) Cat6A cable
Prototypical Room Layout (375 Square Feet)
ACTUAL SIZE: 305 S.F.TOILET: 70 S.F.3/16”=1’
Patient Room, Bariatric
• Overhead pagining speakers in adjacent area corridors• (2) Nurse call pull cord with audio in bathroom
• (1) Nurse call patient station and (1) staff terminal requiring a 3-gang outlet rouhin each• Meets ADA standards
Room Data Sheet
8 Hours/DayUTILIZATION (HOURS OF USE)
14 Hours/Day24 Hours/Day
PowerELECTRICAL
WallWall Voice, Data, Video, MicFloor PowerFloor Voice, Data, Video, MicInstructor’s ConsoleLightingHouse, GeneralLinear Direct/Indirect FixturesTask LightingLighting ControlsDimmingEmergency Power
No LockSECURITY
Keyed LockCard AccessVideo Surveillance
FloorARCHITECTURAL
VCT (Chemical Resistance)VCTWelded Seam Sheet VinylEpoxyCarpetSealed ConcretePartitionsGyp Board, Epoxy PaintGyp Board, PaintVWCGlassOther: Curtain w/ TrackBase4” RubberIntegral w/ FloorOther:CeilingOpenAcoustical TileGyp BoardDoorWoodMetalVision PanelGlass
Standard Hardware SetDOOR HARDWARE
Automatic Door Operators
Temperature: 70-75F & 30-60% MECHANICAL
Heating & Cooling: Maintain 75FVentilation (Per Code)Acoustical Control15 Air Changes/Hour10 Air Changes/Hour6 Air Changes/Hour100% Make-up AirAir Pressure PositiveAir Pressure NegativeHoodsChemical Fume HoodLaminar Flow HoodBiological Safety CabinetSnorkelCanopy HoodOther:
Hand Washing SinkPLUMBING
Multiple Basin SinkFloor DrainFloor SinkSafety Shower/EyewashReverse Osmosis (RO)Carbon Dioxide (CO2)Nitrogen (N2)Oxygen (O2)Natural GasVacuumNitrous OxideCompressed Air
Suppression SystemFIRE SUPPRESSION/DETECTION
Fire ExtinguisherAlarm System Type:
Voice (Telephone)COMMUNICATIONS
Data (Computer)Data (Print/Scan/Fax)Cable TVCampus Closed Circuit TVNurse CallRFID/RTLSIntercomAssisted Listening
Speaker System - OverheadAUDIO/VISUAL
Presentation - DisplayPresentation - Projector/ScreenPresentation - LecternA/V Touch Control PanelAudio Conferencing
Lighting ControlDimmingAV Equipment in RoomAV Equipment in Comm RoomContent/Lecture RecordingOR Integration & ControlOR Scheduling & ManagementDVD/Blu-Ray PlayerDocument Camera
59
Video Conferencing
Special:ACOUSTICS
STP Wall: STP Floor:
See Appendix Table 1See Appendix Table 1
Electric Hardware Set
Volume II | Chapter I
Patient Room, Bariatric
REMARKS/NOTES:
60 Volume II | Chapter I
• (3) Single outlet wall roughin location with (2) Cat6A cables• TV outlet location with (1) Cat6A cable
3/16”=1’
Prototypical Room Layout (375 Square Feet)
ACTUAL SIZE: 305 S.F.TOILET: 70 S.F.
Patient Room, Bariatric ISO
• Overhead pagining speakers in adjacent area corridors• (2) Nurse call pull cord with audio in bathroom
• (1) Nurse call patient station and (1) staff terminal requiring a 3-gang outlet rouhin each• Meets ADA standards
Room Data Sheet
8 Hours/DayUTILIZATION (HOURS OF USE)
14 Hours/Day24 Hours/Day
PowerELECTRICAL
WallWall Voice, Data, Video, MicFloor PowerFloor Voice, Data, Video, MicInstructor’s ConsoleLightingHouse, GeneralLinear Direct/Indirect FixturesTask LightingLighting ControlsDimmingEmergency Power
No LockSECURITY
Keyed LockCard AccessVideo Surveillance
FloorARCHITECTURAL
VCT (Chemical Resistance)VCTWelded Seam Sheet VinylEpoxyCarpetSealed ConcretePartitionsGyp Board, Epoxy PaintGyp Board, PaintVWCGlassOther: Curtain w/ TrackBase4” RubberIntegral w/ FloorOther:CeilingOpenAcoustical TileGyp BoardDoorWoodMetalVision PanelGlass
Standard Hardware SetDOOR HARDWARE
Automatic Door Operators
Temperature: 70-75F & 30-60% MECHANICAL
Heating & Cooling: Maintain 75FVentilation (Per Code)Acoustical Control15 Air Changes/Hour10 Air Changes/Hour6 Air Changes/Hour100% Make-up AirAir Pressure PositiveAir Pressure NegativeHoodsChemical Fume HoodLaminar Flow HoodBiological Safety CabinetSnorkelCanopy HoodOther:
Hand Washing SinkPLUMBING
Multiple Basin SinkFloor DrainFloor SinkSafety Shower/EyewashReverse Osmosis (RO)Carbon Dioxide (CO2)Nitrogen (N2)Oxygen (O2)Natural GasVacuumNitrous OxideCompressed Air
Suppression SystemFIRE SUPPRESSION/DETECTION
Fire ExtinguisherAlarm System Type:
Voice (Telephone)COMMUNICATIONS
Data (Computer)Data (Print/Scan/Fax)Cable TVCampus Closed Circuit TVNurse CallRFID/RTLSIntercomAssisted Listening
Speaker System - OverheadAUDIO/VISUAL
Presentation - DisplayPresentation - Projector/ScreenPresentation - LecternA/V Touch Control PanelAudio Conferencing
Lighting ControlDimmingAV Equipment in RoomAV Equipment in Comm RoomContent/Lecture RecordingOR Integration & ControlOR Scheduling & ManagementDVD/Blu-Ray PlayerDocument Camera
61
Video Conferencing
Special:ACOUSTICS
STP Wall: STP Floor:
See Appendix Table 1See Appendix Table 1
Electric Hardware Set
Volume II | Chapter I
Patient Room, Bariatric ISO
REMARKS/NOTES:
62 Volume II | Chapter I
3/16”=1’
• (3) Single outlet wall roughin location with (2) Cat6A cables• TV outlet location with (1) Cat6A cable
Prototypical Room Layout (315 Square Feet)
ACTUAL SIZE: 273 S.F.TOILET: 42 S.F.
Patient Room, ICU
• Overhead pagining speakers in adjacent area corridors• (2) Nurse call pull cord with audio in bathroom
• (1) Nurse call patient station and (1) staff terminal requiring a 3-gang outlet rouhin each• Meets ADA standards
Room Data Sheet
8 Hours/DayUTILIZATION (HOURS OF USE)
14 Hours/Day24 Hours/Day
PowerELECTRICAL
WallWall Voice, Data, Video, MicFloor PowerFloor Voice, Data, Video, MicInstructor’s ConsoleLightingHouse, GeneralLinear Direct/Indirect FixturesTask LightingLighting ControlsDimmingEmergency Power
No LockSECURITY
Keyed LockCard AccessVideo Surveillance
FloorARCHITECTURAL
VCT (Chemical Resistance)VCTWelded Seam Sheet VinylEpoxyCarpetSealed ConcretePartitionsGyp Board, Epoxy PaintGyp Board, PaintVWCGlassOther: Curtain w/ TrackBase4” RubberIntegral w/ FloorOther:CeilingOpenAcoustical TileGyp BoardDoorWoodMetalVision PanelGlass
Standard Hardware SetDOOR HARDWARE
Automatic Door Operators
Temperature: 70-75F & 30-60% MECHANICAL
Heating & Cooling: Maintain 75FVentilation (Per Code)Acoustical Control15 Air Changes/Hour10 Air Changes/Hour6 Air Changes/Hour100% Make-up AirAir Pressure PositiveAir Pressure NegativeHoodsChemical Fume HoodLaminar Flow HoodBiological Safety CabinetSnorkelCanopy HoodOther:
Hand Washing SinkPLUMBING
Multiple Basin SinkFloor DrainFloor SinkSafety Shower/EyewashReverse Osmosis (RO)Carbon Dioxide (CO2)Nitrogen (N2)Oxygen (O2)Natural GasVacuumNitrous OxideCompressed Air
Suppression SystemFIRE SUPPRESSION/DETECTION
Fire ExtinguisherAlarm System Type:
Voice (Telephone)COMMUNICATIONS
Data (Computer)Data (Print/Scan/Fax)Cable TVCampus Closed Circuit TVNurse CallRFID/RTLSIntercomAssisted Listening
Speaker System - OverheadAUDIO/VISUAL
Presentation - DisplayPresentation - Projector/ScreenPresentation - LecternA/V Touch Control PanelAudio Conferencing
Lighting ControlDimmingAV Equipment in RoomAV Equipment in Comm RoomContent/Lecture RecordingOR Integration & ControlOR Scheduling & ManagementDVD/Blu-Ray PlayerDocument Camera
63
Video Conferencing
Special:ACOUSTICS
STP Wall: STP Floor:
See Appendix Table 1See Appendix Table 1
Electric Hardware Set
Volume II | Chapter I
Patient Room, ICU
REMARKS/NOTES:
64 Volume II | Chapter I
• (3) Single outlet wall roughin location with (2) Cat6A cables• TV outlet location with (1) Cat6A cable
3/16”=1’
Prototypical Room Layout (315 Square Feet)
ACTUAL SIZE: 273 S.F.TOILET: 42 S.F.
Patient Room, ICU ISO
• Overhead pagining speakers in adjacent area corridors• (2) Nurse call pull cord with audio in bathroom
• (1) Nurse call patient station and (1) staff terminal requiring a 3-gang outlet rouhin each• Meets ADA standards
Room Data Sheet
8 Hours/DayUTILIZATION (HOURS OF USE)
14 Hours/Day24 Hours/Day
PowerELECTRICAL
WallWall Voice, Data, Video, MicFloor PowerFloor Voice, Data, Video, MicInstructor’s ConsoleLightingHouse, GeneralLinear Direct/Indirect FixturesTask LightingLighting ControlsDimmingEmergency Power
No LockSECURITY
Keyed LockCard AccessVideo Surveillance
FloorARCHITECTURAL
VCT (Chemical Resistance)VCTWelded Seam Sheet VinylEpoxyCarpetSealed ConcretePartitionsGyp Board, Epoxy PaintGyp Board, PaintVWCGlassOther: Curtain w/ TrackBase4” RubberIntegral w/ FloorOther:CeilingOpenAcoustical TileGyp BoardDoorWoodMetalVision PanelGlass
Standard Hardware SetDOOR HARDWARE
Automatic Door Operators
Temperature: 70-75F & 30-60% MECHANICAL
Heating & Cooling: Maintain 75FVentilation (Per Code)Acoustical Control15 Air Changes/Hour10 Air Changes/Hour6 Air Changes/Hour100% Make-up AirAir Pressure PositiveAir Pressure NegativeHoodsChemical Fume HoodLaminar Flow HoodBiological Safety CabinetSnorkelCanopy HoodOther:
Hand Washing SinkPLUMBING
Multiple Basin SinkFloor DrainFloor SinkSafety Shower/EyewashReverse Osmosis (RO)Carbon Dioxide (CO2)Nitrogen (N2)Oxygen (O2)Natural GasVacuumNitrous OxideCompressed Air
Suppression SystemFIRE SUPPRESSION/DETECTION
Fire ExtinguisherAlarm System Type:
Voice (Telephone)COMMUNICATIONS
Data (Computer)Data (Print/Scan/Fax)Cable TVCampus Closed Circuit TVNurse CallRFID/RTLSIntercomAssisted Listening
Speaker System - OverheadAUDIO/VISUAL
Presentation - DisplayPresentation - Projector/ScreenPresentation - LecternA/V Touch Control PanelAudio Conferencing
Lighting ControlDimmingAV Equipment in RoomAV Equipment in Comm RoomContent/Lecture RecordingOR Integration & ControlOR Scheduling & ManagementDVD/Blu-Ray PlayerDocument Camera
65
Video Conferencing
Special:ACOUSTICS
STP Wall: STP Floor:
See Appendix Table 1See Appendix Table 1
Electric Hardware Set
Volume II | Chapter I
Patient Room, ICU ISO
66 Volume II | Chapter I
3/16”=1’
REMARKS/NOTES:• (4) Single outlet wall roughin location with (2) Cat6A cables• TV outlet location with (1) Cat6A cable
ACTUAL SIZE: 264 S.F.TOILET: 42 S.F.
Prototypical Room Layout (306 Square Feet)
Patient Room, Post Partum
• Overhead pagining speakers in adjacent area corridors• (2) Nurse call pull cord with audio in bathroom• (1) Nurse call patient station and
(1) staff terminal requiring a 3-gang outlet rouhin each• (1) RTLS ceiling mount at room door• Meets ADA standards
Room Data Sheet
8 Hours/DayUTILIZATION (HOURS OF USE)
14 Hours/Day24 Hours/Day
PowerELECTRICAL
WallWall Voice, Data, Video, MicFloor PowerFloor Voice, Data, Video, MicInstructor’s ConsoleLightingHouse, GeneralLinear Direct/Indirect FixturesTask LightingLighting ControlsDimmingEmergency Power
No LockSECURITY
Keyed LockCard AccessVideo Surveillance
FloorARCHITECTURAL
VCT (Chemical Resistance)VCTWelded Seam Sheet VinylEpoxyCarpetSealed ConcretePartitionsGyp Board, Epoxy PaintGyp Board, PaintVWCGlassOther: Curtain w/ TrackBase4” RubberIntegral w/ FloorOther:CeilingOpenAcoustical TileGyp BoardDoorWoodMetalVision PanelGlass
Standard Hardware SetDOOR HARDWARE
Automatic Door Operators
Temperature: 70-75F & 30-60% MECHANICAL
Heating & Cooling: Maintain 75FVentilation (Per Code)Acoustical Control15 Air Changes/Hour10 Air Changes/Hour6 Air Changes/Hour100% Make-up AirAir Pressure PositiveAir Pressure NegativeHoodsChemical Fume HoodLaminar Flow HoodBiological Safety CabinetSnorkelCanopy HoodOther:
Hand Washing SinkPLUMBING
Multiple Basin SinkFloor DrainFloor SinkSafety Shower/EyewashReverse Osmosis (RO)Carbon Dioxide (CO2)Nitrogen (N2)Oxygen (O2)Natural GasVacuumNitrous OxideCompressed Air
Suppression SystemFIRE SUPPRESSION/DETECTION
Fire ExtinguisherAlarm System Type:
Voice (Telephone)COMMUNICATIONS
Data (Computer)Data (Print/Scan/Fax)Cable TVCampus Closed Circuit TVNurse CallRFID/RTLSIntercomAssisted Listening
Speaker System - OverheadAUDIO/VISUAL
Presentation - DisplayPresentation - Projector/ScreenPresentation - LecternA/V Touch Control PanelAudio Conferencing
Lighting ControlDimmingAV Equipment in RoomAV Equipment in Comm RoomContent/Lecture RecordingOR Integration & ControlOR Scheduling & ManagementDVD/Blu-Ray PlayerDocument Camera
67
Video Conferencing
Special:ACOUSTICS
STP Wall: STP Floor:
See Appendix Table 1See Appendix Table 1
Electric Hardware Set
Volume II | Chapter I
Patient Room, Postpartum
68 Volume II | Chapter I
3/16”=1’
REMARKS/NOTES:• Overhead pagining speakers in adjacent area corridors• (2) Nurse call pull cord with audio in bathroom• Meets ADA standards
• (1) Nurse call patient station and (1) staff terminal requiring a 3-gang outlet rouhin each• (1) RTLS ceiling mount at room door
• (4) Single outlet wall roughin location with (2) Cat6A cables• TV outlet location with (1) Cat6A cable
Prototypical Room Layout (315 Square Feet)
ACTUAL SIZE: 273 S.F.TOILET: 42 S.F.
Patient Room, Standard
Room Data Sheet
8 Hours/DayUTILIZATION (HOURS OF USE)
14 Hours/Day24 Hours/Day
PowerELECTRICAL
WallWall Voice, Data, Video, MicFloor PowerFloor Voice, Data, Video, MicInstructor’s ConsoleLightingHouse, GeneralLinear Direct/Indirect FixturesTask LightingLighting ControlsDimmingEmergency Power
No LockSECURITY
Keyed LockCard AccessVideo Surveillance
FloorARCHITECTURAL
VCT (Chemical Resistance)VCTWelded Seam Sheet VinylEpoxyCarpetSealed ConcretePartitionsGyp Board, Epoxy PaintGyp Board, PaintVWCGlassOther: Curtain w/ TrackBase4” RubberIntegral w/ FloorOther:CeilingOpenAcoustical TileGyp BoardDoorWoodMetalVision PanelGlass
Standard Hardware SetDOOR HARDWARE
Automatic Door Operators
Temperature: 70-75F & 30-60% MECHANICAL
Heating & Cooling: Maintain 75FVentilation (Per Code)Acoustical Control15 Air Changes/Hour10 Air Changes/Hour6 Air Changes/Hour100% Make-up AirAir Pressure PositiveAir Pressure NegativeHoodsChemical Fume HoodLaminar Flow HoodBiological Safety CabinetSnorkelCanopy HoodOther:
Hand Washing SinkPLUMBING
Multiple Basin SinkFloor DrainFloor SinkSafety Shower/EyewashReverse Osmosis (RO)Carbon Dioxide (CO2)Nitrogen (N2)Oxygen (O2)Natural GasVacuumNitrous OxideCompressed Air
Suppression SystemFIRE SUPPRESSION/DETECTION
Fire ExtinguisherAlarm System Type:
Voice (Telephone)COMMUNICATIONS
Data (Computer)Data (Print/Scan/Fax)Cable TVCampus Closed Circuit TVNurse CallRFID/RTLSIntercomAssisted Listening
Speaker System - OverheadAUDIO/VISUAL
Presentation - DisplayPresentation - Projector/ScreenPresentation - LecternA/V Touch Control PanelAudio Conferencing
Lighting ControlDimmingAV Equipment in RoomAV Equipment in Comm RoomContent/Lecture RecordingOR Integration & ControlOR Scheduling & ManagementDVD/Blu-Ray PlayerDocument Camera
69
Video Conferencing
Special:ACOUSTICS
STP Wall: STP Floor:
See Appendix Table 1See Appendix Table 1
Electric Hardware Set
Volume II | Chapter I
Patient Room, Standard
70 Volume II | Chapter I
REMARKS/NOTES:• (4) Single outlet wall roughin location with (2) Cat6A cables• TV outlet location with (1) Cat6A cable
Prototypical Room Layout (315 Square Feet)
ACTUAL SIZE: 273 S.F.TOILET: 42 S.F.3/16”=1’
Patient Room, Standard ISO
• Overhead pagining speakers in adjacent area corridors• (2) Nurse call pull cord with audio in bathroom• Meets ADA standards
• (1) Nurse call patient station and (1) staff terminal requiring a 3-gang outlet rouhin each• (1) RTLS ceiling mount at room door
Room Data Sheet
8 Hours/DayUTILIZATION (HOURS OF USE)
14 Hours/Day24 Hours/Day
PowerELECTRICAL
WallWall Voice, Data, Video, MicFloor PowerFloor Voice, Data, Video, MicInstructor’s ConsoleLightingHouse, GeneralLinear Direct/Indirect FixturesTask LightingLighting ControlsDimmingEmergency Power
No LockSECURITY
Keyed LockCard AccessVideo Surveillance
FloorARCHITECTURAL
VCT (Chemical Resistance)VCTWelded Seam Sheet VinylEpoxyCarpetSealed ConcretePartitionsGyp Board, Epoxy PaintGyp Board, PaintVWCGlassOther: Curtain w/ TrackBase4” RubberIntegral w/ FloorOther:CeilingOpenAcoustical TileGyp BoardDoorWoodMetalVision PanelGlass
Standard Hardware SetDOOR HARDWARE
Automatic Door Operators
Temperature: 70-75F & 30-60% MECHANICAL
Heating & Cooling: Maintain 75FVentilation (Per Code)Acoustical Control15 Air Changes/Hour10 Air Changes/Hour6 Air Changes/Hour100% Make-up AirAir Pressure PositiveAir Pressure NegativeHoodsChemical Fume HoodLaminar Flow HoodBiological Safety CabinetSnorkelCanopy HoodOther:
Hand Washing SinkPLUMBING
Multiple Basin SinkFloor DrainFloor SinkSafety Shower/EyewashReverse Osmosis (RO)Carbon Dioxide (CO2)Nitrogen (N2)Oxygen (O2)Natural GasVacuumNitrous OxideCompressed Air
Suppression SystemFIRE SUPPRESSION/DETECTION
Fire ExtinguisherAlarm System Type:
Voice (Telephone)COMMUNICATIONS
Data (Computer)Data (Print/Scan/Fax)Cable TVCampus Closed Circuit TVNurse CallRFID/RTLSIntercomAssisted Listening
Speaker System - OverheadAUDIO/VISUAL
Presentation - DisplayPresentation - Projector/ScreenPresentation - LecternA/V Touch Control PanelAudio Conferencing
Lighting ControlDimmingAV Equipment in RoomAV Equipment in Comm RoomContent/Lecture RecordingOR Integration & ControlOR Scheduling & ManagementDVD/Blu-Ray PlayerDocument Camera
71
Video Conferencing
Special:ACOUSTICS
STP Wall: STP Floor:
See Appendix Table 1See Appendix Table 1
Electric Hardware Set
Volume II | Chapter I
Patient Room, Standard ISO
REMARKS/NOTES:
72
1/4”=1’
Volume II | Chapter I
• (2) Single outlet wall roughin location with (2) Cat6A cables• TV outlet location with (1) Cat6A cable
• (1) RTLS ceiling mount at room door
• Overhead pagining speakers in adjacent area corridors• (1) Nurse patient station requiring a 3- gang outlet roughin
Prototypical Room Layout (140 Square Feet)
ACTUAL SIZE: 140 S.F.
Pre-Op Holding
Room Data Sheet
8 Hours/DayUTILIZATION (HOURS OF USE)
14 Hours/Day24 Hours/Day
PowerELECTRICAL
WallWall Voice, Data, Video, MicFloor PowerFloor Voice, Data, Video, MicInstructor’s ConsoleLightingHouse, GeneralLinear Direct/Indirect FixturesTask LightingLighting ControlsDimmingEmergency Power
No LockSECURITY
Keyed LockCard AccessVideo Surveillance
FloorARCHITECTURAL
VCT (Chemical Resistance)VCTWelded Seam Sheet VinylEpoxyCarpetSealed ConcretePartitionsGyp Board, Epoxy PaintGyp Board, PaintVWCGlassOther: Curtain w/ TrackBase4” RubberIntegral w/ FloorOther:CeilingOpenAcoustical TileGyp BoardDoorWoodMetalVision PanelGlass
Standard Hardware SetDOOR HARDWARE
Automatic Door Operators
Temperature: 70-75F & 30-60% MECHANICAL
Heating & Cooling: Maintain 75FVentilation (Per Code)Acoustical Control15 Air Changes/Hour10 Air Changes/Hour6 Air Changes/Hour100% Make-up AirAir Pressure PositiveAir Pressure NegativeHoodsChemical Fume HoodLaminar Flow HoodBiological Safety CabinetSnorkelCanopy HoodOther:
Hand Washing SinkPLUMBING
Multiple Basin SinkFloor DrainFloor SinkSafety Shower/EyewashReverse Osmosis (RO)Carbon Dioxide (CO2)Nitrogen (N2)Oxygen (O2)Natural GasVacuumNitrous OxideCompressed Air
Suppression SystemFIRE SUPPRESSION/DETECTION
Fire ExtinguisherAlarm System Type:
Voice (Telephone)COMMUNICATIONS
Data (Computer)Data (Print/Scan/Fax)Cable TVCampus Closed Circuit TVNurse CallRFID/RTLSIntercomAssisted Listening
Speaker System - OverheadAUDIO/VISUAL
Presentation - DisplayPresentation - Projector/ScreenPresentation - LecternA/V Touch Control PanelAudio Conferencing
Lighting ControlDimmingAV Equipment in RoomAV Equipment in Comm RoomContent/Lecture RecordingOR Integration & ControlOR Scheduling & ManagementDVD/Blu-Ray PlayerDocument Camera
73
Video Conferencing
Special:ACOUSTICS
STP Wall: STP Floor:
See Appendix Table 1See Appendix Table 1
Electric Hardware Set
Volume II | Chapter I
Pre-Op Holding
REMARKS/NOTES:
74
1/4”=1’
Volume II | Chapter I
• (2) Single outlet wall roughin location with (2) Cat6A cables• TV outlet location with (1) Cat6A cable
• (1) RTLS ceiling mount at room door
• Overhead pagining speakers in adjacent area corridors• (1) Nurse patient station requiring a 3- gang outlet roughin
ACTUAL SIZE: 140 S.F.
Prototypical Room Layout (140 Square Feet)
Recovery Room
Room Data Sheet
8 Hours/DayUTILIZATION (HOURS OF USE)
14 Hours/Day24 Hours/Day
PowerELECTRICAL
WallWall Voice, Data, Video, MicFloor PowerFloor Voice, Data, Video, MicInstructor’s ConsoleLightingHouse, GeneralLinear Direct/Indirect FixturesTask LightingLighting ControlsDimmingEmergency Power
No LockSECURITY
Keyed LockCard AccessVideo Surveillance
FloorARCHITECTURAL
VCT (Chemical Resistance)VCTWelded Seam Sheet VinylEpoxyCarpetSealed ConcretePartitionsGyp Board, Epoxy PaintGyp Board, PaintVWCGlassOther: Curtain w/ TrackBase4” RubberIntegral w/ FloorOther:CeilingOpenAcoustical TileGyp BoardDoorWoodMetalVision PanelGlass
Standard Hardware SetDOOR HARDWARE
Automatic Door Operators
Temperature: 70-75F & 30-60% MECHANICAL
Heating & Cooling: Maintain 75FVentilation (Per Code)Acoustical Control15 Air Changes/Hour10 Air Changes/Hour6 Air Changes/Hour100% Make-up AirAir Pressure PositiveAir Pressure NegativeHoodsChemical Fume HoodLaminar Flow HoodBiological Safety CabinetSnorkelCanopy HoodOther:
Hand Washing SinkPLUMBING
Multiple Basin SinkFloor DrainFloor SinkSafety Shower/EyewashReverse Osmosis (RO)Carbon Dioxide (CO2)Nitrogen (N2)Oxygen (O2)Natural GasVacuumNitrous OxideCompressed Air
Suppression SystemFIRE SUPPRESSION/DETECTION
Fire ExtinguisherAlarm System Type:
Voice (Telephone)COMMUNICATIONS
Data (Computer)Data (Print/Scan/Fax)Cable TVCampus Closed Circuit TVNurse CallRFID/RTLSIntercomAssisted Listening
Speaker System - OverheadAUDIO/VISUAL
Presentation - DisplayPresentation - Projector/ScreenPresentation - LecternA/V Touch Control PanelAudio Conferencing
Lighting ControlDimmingAV Equipment in RoomAV Equipment in Comm RoomContent/Lecture RecordingOR Integration & ControlOR Scheduling & ManagementDVD/Blu-Ray PlayerDocument Camera
75
Video Conferencing
Special:ACOUSTICS
STP Wall: STP Floor:
See Appendix Table 1See Appendix Table 1
Electric Hardware Set
Volume II | Chapter I
Recovery Room
REMARKS/NOTES:
76
1/4”=1’
Volume II | Chapter I
• Card reader with Clinical Staff access• (1) Single outlet wall roughin location with (2) Cat6A cables
• (1) Wall phone with (1) Cat6A cable
ACTUAL SIZE: 120 S.F.
Prototypical Room Layout (120 Square Feet)
Respiratory Therapy Storage
Room Data Sheet
8 Hours/DayUTILIZATION (HOURS OF USE)
14 Hours/Day24 Hours/Day
PowerELECTRICAL
WallWall Voice, Data, Video, MicFloor PowerFloor Voice, Data, Video, MicInstructor’s ConsoleLightingHouse, GeneralLinear Direct/Indirect FixturesTask LightingLighting ControlsDimmingEmergency Power
No LockSECURITY
Keyed LockCard AccessVideo Surveillance
FloorARCHITECTURAL
VCT (Chemical Resistance)VCTWelded Seam Sheet VinylEpoxyCarpetSealed ConcretePartitionsGyp Board, Epoxy PaintGyp Board, PaintVWCGlassOther: Curtain w/ TrackBase4” RubberIntegral w/ FloorOther:CeilingOpenAcoustical TileGyp BoardDoorWoodMetalVision PanelGlass
Standard Hardware SetDOOR HARDWARE
Automatic Door Operators
Temperature: 70-75F & 30-60% MECHANICAL
Heating & Cooling: Maintain 75FVentilation (Per Code)Acoustical Control15 Air Changes/Hour10 Air Changes/Hour6 Air Changes/Hour100% Make-up AirAir Pressure PositiveAir Pressure NegativeHoodsChemical Fume HoodLaminar Flow HoodBiological Safety CabinetSnorkelCanopy HoodOther:
Hand Washing SinkPLUMBING
Multiple Basin SinkFloor DrainFloor SinkSafety Shower/EyewashReverse Osmosis (RO)Carbon Dioxide (CO2)Nitrogen (N2)Oxygen (O2)Natural GasVacuumNitrous OxideCompressed Air
Suppression SystemFIRE SUPPRESSION/DETECTION
Fire ExtinguisherAlarm System Type:
Voice (Telephone)COMMUNICATIONS
Data (Computer)Data (Print/Scan/Fax)Cable TVCampus Closed Circuit TVNurse CallRFID/RTLSIntercomAssisted Listening
Speaker System - OverheadAUDIO/VISUAL
Presentation - DisplayPresentation - Projector/ScreenPresentation - LecternA/V Touch Control PanelAudio Conferencing
Lighting ControlDimmingAV Equipment in RoomAV Equipment in Comm RoomContent/Lecture RecordingOR Integration & ControlOR Scheduling & ManagementDVD/Blu-Ray PlayerDocument Camera
77
Video Conferencing
Special:ACOUSTICS
STP Wall: STP Floor:
Not Applicable
Electric Hardware Set
Volume II | Chapter I
Respiratory Therapy Storage
REMARKS/NOTES:
78
1/4”=1’
Volume II | Chapter I
• Overhead paging speakers in adjacent area corridors
ACTUAL SIZE: 35 S.F.
Prototypical Room Layout (35 Square Feet)
Scrub Alcove
Room Data Sheet
8 Hours/DayUTILIZATION (HOURS OF USE)
14 Hours/Day24 Hours/Day
PowerELECTRICAL
WallWall Voice, Data, Video, MicFloor PowerFloor Voice, Data, Video, MicInstructor’s ConsoleLightingHouse, GeneralLinear Direct/Indirect FixturesTask LightingLighting ControlsDimmingEmergency Power
No LockSECURITY
Keyed LockCard AccessVideo Surveillance
FloorARCHITECTURAL
VCT (Chemical Resistance)VCTWelded Seam Sheet VinylEpoxyCarpetSealed ConcretePartitionsGyp Board, Epoxy PaintGyp Board, PaintVWCGlassOther: Curtain w/ TrackBase4” RubberIntegral w/ FloorOther:CeilingOpenAcoustical TileGyp BoardDoorWoodMetalVision PanelGlass
Standard Hardware SetDOOR HARDWARE
Automatic Door Operators
Temperature: 70-75F & 30-60% MECHANICAL
Heating & Cooling: Maintain 75FVentilation (Per Code)Acoustical Control15 Air Changes/Hour10 Air Changes/Hour6 Air Changes/Hour100% Make-up AirAir Pressure PositiveAir Pressure NegativeHoodsChemical Fume HoodLaminar Flow HoodBiological Safety CabinetSnorkelCanopy HoodOther:
Hand Washing SinkPLUMBING
Multiple Basin SinkFloor DrainFloor SinkSafety Shower/EyewashReverse Osmosis (RO)Carbon Dioxide (CO2)Nitrogen (N2)Oxygen (O2)Natural GasVacuumNitrous OxideCompressed Air
Suppression SystemFIRE SUPPRESSION/DETECTION
Fire ExtinguisherAlarm System Type:
Voice (Telephone)COMMUNICATIONS
Data (Computer)Data (Print/Scan/Fax)Cable TVCampus Closed Circuit TVNurse CallRFID/RTLSIntercomAssisted Listening
Speaker System - OverheadAUDIO/VISUAL
Presentation - DisplayPresentation - Projector/ScreenPresentation - LecternA/V Touch Control PanelAudio Conferencing
Lighting ControlDimmingAV Equipment in RoomAV Equipment in Comm RoomContent/Lecture RecordingOR Integration & ControlOR Scheduling & ManagementDVD/Blu-Ray PlayerDocument Camera
79
Video Conferencing
Special:ACOUSTICS
STP Wall: STP Floor:
Not Applicable
Electric Hardware Set
Volume II | Chapter I
Scrub Alcove
REMARKS/NOTES:
80
1/4”=1’
Volume II | Chapter I
• Card reader with Clinical Staff access
ACTUAL SIZE: 115 S.F.
Prototypical Room Layout (300 Square Feet)
Soiled Holding
Room Data Sheet
8 Hours/DayUTILIZATION (HOURS OF USE)
14 Hours/Day24 Hours/Day
PowerELECTRICAL
WallWall Voice, Data, Video, MicFloor PowerFloor Voice, Data, Video, MicInstructor’s ConsoleLightingHouse, GeneralLinear Direct/Indirect FixturesTask LightingLighting ControlsDimmingEmergency Power
No LockSECURITY
Keyed LockCard AccessVideo Surveillance
FloorARCHITECTURAL
VCT (Chemical Resistance)VCTWelded Seam Sheet VinylEpoxyCarpetSealed ConcretePartitionsGyp Board, Epoxy PaintGyp Board, PaintVWCGlassOther: Curtain w/ TrackBase4” RubberIntegral w/ FloorOther:CeilingOpenAcoustical TileGyp BoardDoorWoodMetalVision PanelGlass
Standard Hardware SetDOOR HARDWARE
Automatic Door Operators
Temperature: 70-75F & 30-60% MECHANICAL
Heating & Cooling: Maintain 75FVentilation (Per Code)Acoustical Control15 Air Changes/Hour10 Air Changes/Hour6 Air Changes/Hour100% Make-up AirAir Pressure PositiveAir Pressure NegativeHoodsChemical Fume HoodLaminar Flow HoodBiological Safety CabinetSnorkelCanopy HoodOther:
Hand Washing SinkPLUMBING
Multiple Basin SinkFloor DrainFloor SinkSafety Shower/EyewashReverse Osmosis (RO)Carbon Dioxide (CO2)Nitrogen (N2)Oxygen (O2)Natural GasVacuumNitrous OxideCompressed Air
Suppression SystemFIRE SUPPRESSION/DETECTION
Fire ExtinguisherAlarm System Type:
Voice (Telephone)COMMUNICATIONS
Data (Computer)Data (Print/Scan/Fax)Cable TVCampus Closed Circuit TVNurse CallRFID/RTLSIntercomAssisted Listening
Speaker System - OverheadAUDIO/VISUAL
Presentation - DisplayPresentation - Projector/ScreenPresentation - LecternA/V Touch Control PanelAudio Conferencing
Lighting ControlDimmingAV Equipment in RoomAV Equipment in Comm RoomContent/Lecture RecordingOR Integration & ControlOR Scheduling & ManagementDVD/Blu-Ray PlayerDocument Camera
81
Video Conferencing
Special:ACOUSTICS
STP Wall: STP Floor:
Not Applicable
Electric Hardware Set
Volume II | Chapter I
Soiled Holding
REMARKS/NOTES:
82 Volume II | Chapter I
• Card reader with Clinical Staff access
ACTUAL SIZE: 120 S.F.
Prototypical Room Layout (120 Square Feet)
3/16”=1’
Soiled Utility
Room Data Sheet
8 Hours/DayUTILIZATION (HOURS OF USE)
14 Hours/Day24 Hours/Day
PowerELECTRICAL
WallWall Voice, Data, Video, MicFloor PowerFloor Voice, Data, Video, MicInstructor’s ConsoleLightingHouse, GeneralLinear Direct/Indirect FixturesTask LightingLighting ControlsDimmingEmergency Power
No LockSECURITY
Keyed LockCard AccessVideo Surveillance
FloorARCHITECTURAL
VCT (Chemical Resistance)VCTWelded Seam Sheet VinylEpoxyCarpetSealed ConcretePartitionsGyp Board, Epoxy PaintGyp Board, PaintVWCGlassOther: Curtain w/ TrackBase4” RubberIntegral w/ FloorOther:CeilingOpenAcoustical TileGyp BoardDoorWoodMetalVision PanelGlass
Standard Hardware SetDOOR HARDWARE
Automatic Door Operators
Temperature: 70-75F & 30-60% MECHANICAL
Heating & Cooling: Maintain 75FVentilation (Per Code)Acoustical Control15 Air Changes/Hour10 Air Changes/Hour6 Air Changes/Hour100% Make-up AirAir Pressure PositiveAir Pressure NegativeHoodsChemical Fume HoodLaminar Flow HoodBiological Safety CabinetSnorkelCanopy HoodOther:
Hand Washing SinkPLUMBING
Multiple Basin SinkFloor DrainFloor SinkSafety Shower/EyewashReverse Osmosis (RO)Carbon Dioxide (CO2)Nitrogen (N2)Oxygen (O2)Natural GasVacuumNitrous OxideCompressed Air
Suppression SystemFIRE SUPPRESSION/DETECTION
Fire ExtinguisherAlarm System Type:
Voice (Telephone)COMMUNICATIONS
Data (Computer)Data (Print/Scan/Fax)Cable TVCampus Closed Circuit TVNurse CallRFID/RTLSIntercomAssisted Listening
Speaker System - OverheadAUDIO/VISUAL
Presentation - DisplayPresentation - Projector/ScreenPresentation - LecternA/V Touch Control PanelAudio Conferencing
Lighting ControlDimmingAV Equipment in RoomAV Equipment in Comm RoomContent/Lecture RecordingOR Integration & ControlOR Scheduling & ManagementDVD/Blu-Ray PlayerDocument Camera
83
Video Conferencing
Special:ACOUSTICS
STP Wall: STP Floor:
Not Applicable
Electric Hardware Set
Volume II | Chapter I
Soiled Utility
REMARKS/NOTES:
84
1/4”=1’
Volume II | Chapter I
• Overhead pagining speakers in adjacent area corridors and room
• (1) Single outlet wall roughin location with (2) Cat6A cables• (1) Wall phone with (1) Cat6A cable
Prototypical Room Layout (360 Square Feet)
ACTUAL SIZE: 360 S.F.
Staff Lounge
• TV outlet location with (1) Cat6A cable• Card reader with Physician access
Room Data Sheet
8 Hours/DayUTILIZATION (HOURS OF USE)
14 Hours/Day24 Hours/Day
PowerELECTRICAL
WallWall Voice, Data, Video, MicFloor PowerFloor Voice, Data, Video, MicInstructor’s ConsoleLightingHouse, GeneralLinear Direct/Indirect FixturesTask LightingLighting ControlsDimmingEmergency Power
No LockSECURITY
Keyed LockCard AccessVideo Surveillance
FloorARCHITECTURAL
VCT (Chemical Resistance)VCTWelded Seam Sheet VinylEpoxyCarpetSealed ConcretePartitionsGyp Board, Epoxy PaintGyp Board, PaintVWCGlassOther: Curtain w/ TrackBase4” RubberIntegral w/ FloorOther:CeilingOpenAcoustical TileGyp BoardDoorWoodMetalVision PanelGlass
Standard Hardware SetDOOR HARDWARE
Automatic Door Operators
Temperature: 70-75F & 30-60% MECHANICAL
Heating & Cooling: Maintain 75FVentilation (Per Code)Acoustical Control15 Air Changes/Hour10 Air Changes/Hour6 Air Changes/Hour100% Make-up AirAir Pressure PositiveAir Pressure NegativeHoodsChemical Fume HoodLaminar Flow HoodBiological Safety CabinetSnorkelCanopy HoodOther:
Hand Washing SinkPLUMBING
Multiple Basin SinkFloor DrainFloor SinkSafety Shower/EyewashReverse Osmosis (RO)Carbon Dioxide (CO2)Nitrogen (N2)Oxygen (O2)Natural GasVacuumNitrous OxideCompressed Air
Suppression SystemFIRE SUPPRESSION/DETECTION
Fire ExtinguisherAlarm System Type:
Voice (Telephone)COMMUNICATIONS
Data (Computer)Data (Print/Scan/Fax)Cable TVCampus Closed Circuit TVNurse CallRFID/RTLSIntercomAssisted Listening
Speaker System - OverheadAUDIO/VISUAL
Presentation - DisplayPresentation - Projector/ScreenPresentation - LecternA/V Touch Control PanelAudio Conferencing
Lighting ControlDimmingAV Equipment in RoomAV Equipment in Comm RoomContent/Lecture RecordingOR Integration & ControlOR Scheduling & ManagementDVD/Blu-Ray PlayerDocument Camera
85
Video Conferencing
Special:ACOUSTICS
STP Wall: STP Floor:
Not Applicable
Electric Hardware Set
Volume II | Chapter I
Staff Lounge
REMARKS/NOTES:
86
1/4”=1’
Volume II | Chapter I
• (4) Single outlet wall roughin location with (2) Cat6A cables• Card reader with Clinical Staff access
• Overhead pagining speakers in adjacent area corridors and room• (1) Nurse patient station requiring a 3- gang outlet roughin
Prototypical Room Layout (180 Square Feet)
ACTUAL SIZE: 180 S.F.
Stress Testing Lab
Room Data Sheet
8 Hours/DayUTILIZATION (HOURS OF USE)
14 Hours/Day24 Hours/Day
PowerELECTRICAL
WallWall Voice, Data, Video, MicFloor PowerFloor Voice, Data, Video, MicInstructor’s ConsoleLightingHouse, GeneralLinear Direct/Indirect FixturesTask LightingLighting ControlsDimmingEmergency Power
No LockSECURITY
Keyed LockCard AccessVideo Surveillance
FloorARCHITECTURAL
VCT (Chemical Resistance)VCTWelded Seam Sheet VinylEpoxyCarpetSealed ConcretePartitionsGyp Board, Epoxy PaintGyp Board, PaintVWCGlassOther: Curtain w/ TrackBase4” RubberIntegral w/ FloorOther:CeilingOpenAcoustical TileGyp BoardDoorWoodMetalVision PanelGlass
Standard Hardware SetDOOR HARDWARE
Automatic Door Operators
Temperature: 70-75F & 30-60% MECHANICAL
Heating & Cooling: Maintain 75FVentilation (Per Code)Acoustical Control15 Air Changes/Hour10 Air Changes/Hour6 Air Changes/Hour100% Make-up AirAir Pressure PositiveAir Pressure NegativeHoodsChemical Fume HoodLaminar Flow HoodBiological Safety CabinetSnorkelCanopy HoodOther:
Hand Washing SinkPLUMBING
Multiple Basin SinkFloor DrainFloor SinkSafety Shower/EyewashReverse Osmosis (RO)Carbon Dioxide (CO2)Nitrogen (N2)Oxygen (O2)Natural GasVacuumNitrous OxideCompressed Air
Suppression SystemFIRE SUPPRESSION/DETECTION
Fire ExtinguisherAlarm System Type:
Voice (Telephone)COMMUNICATIONS
Data (Computer)Data (Print/Scan/Fax)Cable TVCampus Closed Circuit TVNurse CallRFID/RTLSIntercomAssisted Listening
Speaker System - OverheadAUDIO/VISUAL
Presentation - DisplayPresentation - Projector/ScreenPresentation - LecternA/V Touch Control PanelAudio Conferencing
Lighting ControlDimmingAV Equipment in RoomAV Equipment in Comm RoomContent/Lecture RecordingOR Integration & ControlOR Scheduling & ManagementDVD/Blu-Ray PlayerDocument Camera
87
Video Conferencing
ACOUSTICS
Electric Hardware Set
Volume II | Chapter I
Stress Testing Lab
Special: Walls to Deck with
Located in WallsSound Batt Insulation
REMARKS/NOTES:
88
1/4”=1’
Volume II | Chapter I
• (3) Single outlet wall roughin location with (2) Cat6A cables• (1) Wall phone with (1) Cat6A cable
Prototypical Room Layout (180 Square Feet)
ACTUAL SIZE: 180 S.F.
Team Workroom
• (1) Single TV Outlet location• Card reader with Clinical Staff access
• Overhead pagining speakers in adjacent area corridors and room• (1) Nurse patient station requiring a 3- gang outlet roughin
Room Data Sheet
8 Hours/DayUTILIZATION (HOURS OF USE)
14 Hours/Day24 Hours/Day
PowerELECTRICAL
WallWall Voice, Data, Video, MicFloor PowerFloor Voice, Data, Video, MicInstructor’s ConsoleLightingHouse, GeneralLinear Direct/Indirect FixturesTask LightingLighting ControlsDimmingEmergency Power
No LockSECURITY
Keyed LockCard AccessVideo Surveillance
FloorARCHITECTURAL
VCT (Chemical Resistance)VCTWelded Seam Sheet VinylEpoxyCarpetSealed ConcretePartitionsGyp Board, Epoxy PaintGyp Board, PaintVWCGlassOther: Curtain w/ TrackBase4” RubberIntegral w/ FloorOther:CeilingOpenAcoustical TileGyp BoardDoorWoodMetalVision PanelGlass
Standard Hardware SetDOOR HARDWARE
Automatic Door Operators
Temperature: 70-75F & 30-60% MECHANICAL
Heating & Cooling: Maintain 75FVentilation (Per Code)Acoustical Control15 Air Changes/Hour10 Air Changes/Hour6 Air Changes/Hour100% Make-up AirAir Pressure PositiveAir Pressure NegativeHoodsChemical Fume HoodLaminar Flow HoodBiological Safety CabinetSnorkelCanopy HoodOther:
Hand Washing SinkPLUMBING
Multiple Basin SinkFloor DrainFloor SinkSafety Shower/EyewashReverse Osmosis (RO)Carbon Dioxide (CO2)Nitrogen (N2)Oxygen (O2)Natural GasVacuumNitrous OxideCompressed Air
Suppression SystemFIRE SUPPRESSION/DETECTION
Fire ExtinguisherAlarm System Type:
Voice (Telephone)COMMUNICATIONS
Data (Computer)Data (Print/Scan/Fax)Cable TVCampus Closed Circuit TVNurse CallRFID/RTLSIntercomAssisted Listening
Speaker System - OverheadAUDIO/VISUAL
Presentation - DisplayPresentation - Projector/ScreenPresentation - LecternA/V Touch Control PanelAudio Conferencing
Lighting ControlDimmingAV Equipment in RoomAV Equipment in Comm RoomContent/Lecture RecordingOR Integration & ControlOR Scheduling & ManagementDVD/Blu-Ray PlayerDocument Camera
89
Video Conferencing
ACOUSTICS
Electric Hardware Set
Volume II | Chapter I
Team Workroom
Special: Walls to Deck with
Located in WallsSound Batt Insulation
90 Volume II | Chapter I
Appendix
91Volume II | Chapter I
Appendix
Table 1