Rotary Air-conditioning Compressors

Specification

YZG-Q036AY4 Compressor Model

The Customer

Air-conditioner Model

QQQQIIIINGANNGANNGANNGAN SIGNSIGNSIGNSIGNAAAATURETURETURETURE

CCCCUUUUSTOMSTOMSTOMSTOMEEEERRRR’SSSS APPROAPPROAPPROAPPROVVVVALALALAL

This document will be effective with your authorized signature .please return one

copy of this document.

Compile:

Examine:

Approve:

Xi’an Qing’an Refrigeration Equipment Co., Ltd

共 11 页/ 11page altogether

YYYYZGZGZGZG----QQQQ000033336666AYAYAYAY4444////GGGGSSSS----000000001111BBBB

2

1. Specification of Compressor

1.1 Application Scope

Air-conditioner Type Cooling

Refrigerant

R134a

Range of Ambient temperature 15~43

Range of evaporating temperature -10~15

Range of Cond 0

ensing temperature -0.15 35~56

Rated Voltage / Frequency / Phase 220V-240V~/50Hz/1Φ

Approval Type CCC、TUV、CE

1.2 Basic Specification

Compressor Type Hermetic Rotary Compressor

Displacement

3.57 cm3/rev

Cylinder Number

1

Suction Tube(I.D)

Φ6.5 0

mm -0.15

Discharge Tube(I.D)

Φ5.7+0.15

mm +0.05

Net Weight (Oil Included)

3.70kg

Oil & Oil Charge

RB68EP &100mL

Painting 黑色 Black Color Paint

1.3 Specification of Motor

Motor Type Single Phase Motor

Pole 2 2 Pole

Winding resistance (at 20) Main40Ω±10% Sub 56.7Ω±10%

Rated Voltage / Frequency / Phase 220V-240V~/50Hz/1Φ

Rated Revolution

2805 rev/min

Motor Starting Type Permanent Split Capacitor

3

YYYYZGZGZGZG----QQQQ000033336666AYAYAYAY4444////GGGGSSSS----000000001111BBBB

1.4 Electrical Component

Parts Name Specification

Running Capacitor (Self Provided)

5.5µF/400V·AC

Overload Protector (Outer)

BF130-JB

2. Performance Parameter

2.1 Test Condition & Performance

Parts Name Unit Numerical Value

Cooling Capacity W︱Btu

≥385×95%︱1314×95%

(at 220V)

Input Power W

≤170×105%

(at220V)

Current A

≤0.8×105%

(at 220V)

EER W/W︱Btu/W

≥2.25×95%︱7.73×95%

(at 220V)

Noise dB(A)

≤53

Vibration

m/s2

≤15

Test Condition

w w

Rated Voltage / Frequency / Phase

Condensing temperature

: 220V-240V~/50Hz/1Φ

:54.4 w Evaporating temperature :7.2 w Suction Gas temperature :35 w Degree of Super-cooling :8.3 w Ambient temperature :35

2.2 Starting & Running

Parts Name Unit Numerical Value

Locked rotor amps A

2.25

(at 220V)

Starting Voltage V

≥187

Running Voltage Range V 198~242

4

YYYYZGZGZGZG----QQQQ000033336666AYAYAYAY4444////GGGGSSSS----000000001111BBBB

2.3 Other Characteristics

Parts Name Unit Numerical Value

Leakage Testing Pressure

MPa

2.12

Shell Mechanical Strength Pressure

MPa

7.42

Insulation Class

B Class

Insulation Resistance

≥30

Electric Strength 1500V 1min

or 1800V 1sec

Residual Moisture

mg

≤75

Residual Impurity

mg

≤20

Grounding Resistance

Ω

≤0.1

The Max. Filling Amount of Refrigerant

g

240

3. Capability Curve of Compressor

220V Capability curves of compressor at 220V annex

4. Operating Conditions of Compressor

Q/1QAJ1009-2007《》 Elaborate on Q/1QAJ1009-2007《The use condition of fixed REV Rotary Compressors》

5. Parts and Drawing List

Parts Name Code QTY/Set Remarks

Compressor

YZG-Q036AY4

1 Shape

Electric Container Cap

YZG/AZ-00-16

1

Spring clip

YZG/AZ-00-17

1

Rubber Pad

YZG/AZ-00-19

1

Absorber Support

YZG/AZ-00-18

3

Outer compound protector

BF130-JB

1

Electric Wiring Diagram

Accessories Installation

Diagram

5

YYYYZGZGZGZG----QQQQ000033336666AYAYAYAY4444////GGGGSSSS----000000001111BBBB

6. The Period of Validity

This document will take effect after the confirmation of your company with the authorized signature when

design modification is approved by the customer, the current document is unavailable.

top related