roundit v0 emi cu/sn...iec 60096-1 triaxial method on straight installation lt = 1.2 nh: tel: +44(0)...

Post on 11-Aug-2021

2 Views

Category:

Documents

0 Downloads

Preview:

Click to see full reader

TRANSCRIPT

ROUNDIT® V0 EMI Cu/Sn

Product Highlights• Operatingtemperature

-40°Cto+125°C(-40°Fto+257°F)

• Self-wrappingdesign

• FastandeasyinstallationforlocalEMIprotection

• Stableconstruction

• Idealforreworkingcomponentswithoutdisconnectingthem

• ZeroHalogen

• UL94V0Rawmaterial

• Cu/Snmetal(EN13602)

• GoodlevelofEMIshieldingR0max=6mΩ andLt=1.2nH/m

ROUNDIT® V0 EMI Cu/Snisawrap-aroundsleevingdesignedforhighperformanceEMIshieldingofwireandcablebundles.ROUNDITV0EMICu/SnismanufacturedfromUL94V0ratedPPSmonofilamentsandtinplatedcopperwiresaccordingtoEN13602.

Theself-wrappingfeatureofROUNDITV0EMICu/Snallowsforquickandeasyinstallationandremovaloftheproductforassemblyandmaintenance.

Thedesignoffersinnovativesolutionstotheprotectionofbreakoutareasandalsoprovideseaseofremovalwheninspectionormaintenanceofcablesisnecessary.

ThestableconstructionguaranteesthesamelevelofEMIshieldingregardlessofthediameteronwhichitisinstalledwithintherecommendedapplicationrange.

Asanadditionalbenefit,ROUNDITV0EMICu/Snenablesuserstostockalimitedrangeofsizestocoverawiderangeofcableandwirediameters.

ROUNDITV0EMICu/Snhasmanyapplicationsintherailway,marineandelectronicsindustries.

Our manufacturing sites are certified ISO 9001, ISO/TS 16949,or AS/EN 9100, and ISO 14001

RIV0EMICUSN_11212012

Asanaddedbenefit,thepatentedROUNDIT®ToolwillhelpimproveinstallationtimeandisdesignedtoinstallROUNDIT®productsoncableandwireconfigurations.

-

Performance Data – ROUNDIT® V0 EMI Cu/Sn

*Nominalsizeisdeterminedbywrappingtheproductaroundamandrelofagivensizetoobtain90degreesofoverlap(averagevalue).**Size45has80degreesofoverlap(averagevalue).

Commercial Part NumberExample: ProductName Size Color Quantity ROUNDITV0EMICu/Sn 13 8(lightgray) 250m

Commercial Part Number

Nominal Size*(mm)

Recommended Application Range mm (in)

Cross Section (mm²)

Maximum Mass g/m

Standard Packaging

m (ft)Min Ø Max Ø

ROUNDITV0EMICu/Sn8 8 5(3/16”) 8(5/16”) 3.5 40 250(820’)

ROUNDITV0EMICu/Sn13 13 8(5/16”) 13(1/2”) 4.8 55 175(574’)

ROUNDITV0EMICu/Sn19 19 13(1/2”) 19(3/4”) 5.9 66 125(410’)

ROUNDITV0EMICu/Sn25 25 19(3/4”) 25(1”) 6.9 80 75(246’)

ROUNDITV0EMICu/Sn32 32 25(1”) 32(1-1/4”) 8.9 105 50(164’)

ROUNDITV0EMICu/Sn38 38 32(1-1/4”) 38(1-1/2”) 10.6 120 35(114’)

ROUNDITV0EMICu/Sn45** 45 38(1-1/2”) 45(1-3/4”) 11.9 140 35(114’)

Product Specifications

Property Test Method Result

PHYSICAL

Operatingtemperaturerange -40ºCto+125ºC(-40°Fto+257°F)

Fire/Smoke/Toxicity UL94DIN5510§2&54837

RawmaterialclassifiedV0S4,SR2,ST2

CHEMICAL

Fluidresistance-Hydraulicfluids:NATO.0.156

EN6059-303Immersionfor24hrsat+70°C

D471924

Novisibledegradationafterbeingexposed

Saltsprayresistance EN2591-307-96hours Pass

EMI PERFORMANCE

ResistanceMeasurement

EN3475-301R0maxallsizes=6mΩ

TransferImpedanceIEC60096-1TriaxialmethodonstraightinstallationLt=1.2nH

Tel: +44(0) 1793616700 • Fax: +44(0) 1793 644304uksales@is-rayfast.com • export@is-rayfast.com

www.is-rayfast.com2 Lydiard Fields, Swindon, Wiltshire, SN5 8UB

top related