shared trench detail-nbncdn2.blocksassets.com/assets/mirvac-dev/gainsborough... · 2018. 4. 10. ·...

Post on 13-Sep-2020

3 Views

Category:

Documents

0 Downloads

Preview:

Click to see full reader

TRANSCRIPT

ACCURATE OR COMPLETE.

DRAWING TITLE:

PROJECT No:

SCALE SHEET No. REV.

QUALITY RECORD :

APPROVED

NBNCO APPROVAL RECORD:

DD

AB

WD

REV DATE DESCRIPTION

SIGNATURE DATE

IT SHOULD NOT BE SCALED TO LOCATE NBNCO ASSETS.

USE OF NBNCO LIMITED (ABN 86 136 533 741)THIS DOCUMENT HAS BEEN PREPARED SOLELY FOR THE

NBNCO DISCLAIMER

NO WARRANTY IS GIVEN THAT THE INFORMATION IS

FOR USE IN MAINTAINING NBNCO FACILITIES.IT HAS NOT BEEN CREATED FOR ANY OTHER USE.

CADREF No:

NN KEY PLAN

OF

LimitedFSA:

STATE: REGION:

FSAM:

DRAFTER

FDA:

**ATTENTION** CONSTRUCTORSDO NOT change or alter job

specifications unless first checkingwith designer.

MAP1

MAP3 MAP4

MAP2

SHEET1

1 2 3 4 5 6 7 8 9 10 11 12

1 2 3 4 5 6 7 8 9 10 11 12

A

B

C

D

E

F

G

H

A

B

C

D

E

F

G

H

Stafford, QLD 4053204/6 Babarra Street

Fax: (07) 3872 5566Tel: (07) 3872 5555

E: rr@robrus.com.au& ASSOCIATES PTY. LTD.

Robin

Russell

CONSULTING ENGINEERS - ELECTRICAL

www.robrus.com.au

A.B.N. 78 010 589 661

GAINSBOROUGH GREENS PRECINCT 7.2BYAWALPAH ROADPIMPAMA

QLD

AYCA-3QMMOS

B579

1:1000 1 1 C

A 13/09/2016 SHANE MILLS ORIGINAL K.R.

B 20/02/2017 SHANE MILLS REVISED CIVIL BASE K.R.

C 05/12/2017 A.C. AS BUILT S.M.

LEGEND: NBN CONDUITS & PITS

Fibre Distribution Hub (FDH) site - 1m x 1m

Fibre Access Node (FAN) site

Local Network PitPremises Connection (Houses an MPT)Boundary PitCross-Road & Other Premises Connection (No MPT)Local Network Connection PitPremises Connection & Fibre Splice ClosureDistribution Pitat entry/exit to estate; @ 250m ccs on distribution conduit

Fibre Distribution Hub (FDH) PitWithin 5m of FDH Site

FAN(2ARM)

Marker Post(Post to be numbered)

FDH-ID576

RC183A 22 Multi Dwelling Unit (MDU)

Descriptor Box(Description of type of work & Quantity involved)

DESCQTY

T Existing Telstra conduit trench layout(Proposed conduit indicated for comms cable)

Existing or proposed Energex pole (& pole ID)ID-001

Existing Telstra Exchange

Existing Telstra Pits (size 2,3,4,5,6,7,8 or 9)

Existing Telstra Manholes (Access Chambers)

Existing Traffic Signals Box

Existing network item to be removed/replaced

TransformerPad Mount / Pole Mount

PWR

Depth over alignment indicator(used with every Marker Post)

Proposed 100mm Main Conduit

Proposed 23mm Service Drop

TRF

Proposed shared trench

Proposed 50mm Lateral Conduit

Proposed length of bored conduit

Service Drop Access Pit

Existing NBN 100mm conduit

Existing Telstra P100 conduit

DEPTH-ALIGN -_._

_._

5

M01

PIT-XXX2

PIT-XXX5

PIT-XXX5

PIT-XXX8

PIT-XXX8

PIT-XXX9

P100 40

P50 25

P23 7

'C' communications marker plate

COM

1200mm

LV

A

B

GROUND LEVEL

SECTION VIEW

TAPE

LOCATION A

MINIMUM CONDUIT DEPTH *

Verge 450mm

Local Road 600mm

DTMR Road 800mm

B

750mm

Energex 800mm; Ergon 900mm

LV

100m

m

SHARED TRENCH DETAIL-NBN

PROP

ERTY

BOU

NDAR

Y

* supercedes Energex/Ergon requirements

PIT

PIT

Property Boundary

Kerb

ROAD

NO PITS IN THE SHADED AREA

MIN. 3m MIN. 1m

MIN.

1mMI

N. 3m

ROADFOOTPATH

AS CONSTRUCTED

1053

//

//

//

//

//

ROAD 1

ROAD 1

MOWBRAY

ST

MTROYAL

ST

CONIMBLA ST

KOSCIUSZKO CCT

GOLD COAST RAILWAY LINE

GOLD COAST RAILWAY LINE

(DUPLEX)

(DUPLEX)

BUTTERFEAF CR

KUMBATINE

ST

MT ROYAL ST

BARAKEE ST

BUTTERFEAF CR

GREAT

SANDY CCT

GREAT SANDY CCT

GREAT SANDY CCT

GREAT SANDY CCT

TOONUMBA ST

BUTTERLE

AF CRNANGAR ST

NANGAR ST

BUTTERFEAF CR

DUPLEX

DUPLEX

DUPLEX

DUPLEX

DUPLEX

PIT-0048

PIT-0055

PIT-0062

PIT-0072

PIT-0085PIT-0092PIT-0105

PIT-0112PIT-0125

PIT-0138

PIT-0148

PIT-0158

PIT-0165

PIT-0175

PIT-0185

PIT-01

92

PIT-0205

PIT-0218

PIT-0225

PIT-0235

PIT-0245

PIT-0252

PIT-0265

PIT-0272

PIT-028

PIT-0335

PIT-0348

PIT-0355

PIT-0368

PIT-0375

PIT-0388

PIT-0395

PIT-0405

PIT-0415

PIT-0428

PIT-0435

PIT-0442 PIT-0455

PIT-0462 PIT-

0475

PIT-0485

PIT-0492

PIT-0505

PIT-0518

160.3

P100

41.1

P100

P100

38.5

P100

42.9

P100

34.1

P100

50.8

P100

52.6P100

43.6P100

27.8

P100

45.0

P10012.2

P100

42.2

P100

27.7

P10015.5

P100

33.7

P50

53.0

P100

39.6

P100

33.6

P100

26.0

P100

33.5

P100

42.9

P100

35.5

P100

24.7

P100

33.2

P100

18.2

P100

40.0

P50

28.1

P1001.0

P10012.4

P100

26.2

P5017.3

P100

27.4

P100

26.7

P100

26.2

P100

18.6

P10013.7

P50

29.7

Development InformationDevelopment Name: Developer Company:

Authorised Rep:

Development Adress:

CRM ID: Stage Number:

Phone:E-Mail:

GAINSBOROUGH GREENS MIRVAC PACIFIC P/L

YAWALPAH ROAD, PIMPAMA

AYCA-3QMMOS PRECINCT 7.2B

TOM ALLISON07 3859 5888tom.allison@mirvac.com

1035

1036

1037

1038

1039

1040

1041

1047

1042

1043

1044

1045

1046

1048

1049

1050

1051

1052

1053

1023

1024

1025

1026

1027

1028

1029

1030

1031

1032

1033

1034

1019

1020

1021

1022

1054

1055

1056

1057

1058

1059

1060

1061

1062

1063

1064

1065

1066

1067

1091

1092

1093

1094

1095

1096

1097

1098

1099

1100

1101

1102

1103

1104

1105

1106

1113

1128

1114

1115

1116

1117

P203.0

P203.0

P203.0

P203.0

P203.0

P203.0

P203.0

P203.0

P203.0

P203.0

P203.0

P203.0

P203.0

P203.0

P203.0

P203.0

P203.0

P2013.0

P2017.0

P203.0

P203.0

P206.0

P2017.0

P203.0

P203.0

P203.0

P203.0

P203.0

P203.0

P203.0

P203.0

P2017.0

P203.0

P203.0

P203.0

P203.0

P203.0

P203.0

P203.0

P203.0

P203.0

P203.0

P203.0

P203.0

P203.0

P2011.0

P203.0

P203.0

P203.0

PIT-0539

P1002.0

FDH-XXX

P1005.0

P100

46.0

P100

24.6

P50

19.3

P100

23.0

P100

25.8

P5017.1

P50 18.6

P50

29.8

P50

34.8

P5017.2

P50

17.6

P100

36.4

P100

23.7

P203.0

P203.0

P203.0

P203.0

P203.0

P203.0

P203.0

P203.0

P203.0

P203.0

P203.0

P203.0

P203.0

P203.0

P2014.0

P203.0

P2016.0

P203.0

P203.0

P203.0

P203.0

P203.0

P203.0

P203.0

P203.0

P203.0

P203.0

P20

P50

19.2

1068

1069

1070

1071

1072

1073

1074

1075

1076

1077

1078

1079

1172

1173

1174

1165

1166

1167

1158

1159

1160

1161

1162

1146

1147

1148

1149

1082

1083

1084

1085

1086

1087

1088

1089

1090

1139

1140

1141

1142

1143

1144

1145

1150

1151

1152

1153

1154

1168

1169

1170

1171

1080

1081

PIT-00

15

PIT-00

25

PIT-00

35

PIT-00

45

PIT-0

055

PIT-0

065

PIT-0075PIT-00

82

PIT-0098

PIT-0108PIT-0118

PIT-0125

PIT-0132

PIT-0142

PIT-0155

PIT-0165

PIT-0

175

PIT-0

185

PIT-01

95

PIT-02

0

2

PIT-02

1

8

PIT-02

2

5

PIT-0238

PIT-0245

PIT-0252

PIT-0262

PIT-0275

PIT-0288

PIT-0295

PIT-0305

PIT-0315

PIT-0325

P100

16

P100

31.7

P100

38

P100

39.6

P100

36.8

P100

34.4

P50

35.6

P100

47

P100

31.9

P10017.9

P50

33.5

P5018.7

P100

29.3

P1001

P100

49.2

P100

35.6

P1001

P501

P100

13.9

P100

23.6

P100

25.8

P5017.7

P100

27.9

P100

48.1

P100

37.4

P50

29.3

P10017.3

P100

27.6

P100

16.9

P203

P2010

P203

P203

P203

P203

P203

P203

P203

P203

P203

P203

P203

P2015

P203

P203

P203

P203

P203

P203

P203

P203

P203

P203

P203

P203

P203

P203

P203

P203

P203

P203

P203

P203

P203

P203

P203

P203

P203

P203

P203

P203

P203

P203

P203

P203

P203

P203

P10017.6

P203

P203

P203

P2012

P203

P203

P203

P203

P203

P203

P203

P203

CONNECT TO EXISTINGNBN CONDUIT

CONNECT TO EXISTINGNBN CONDUIT

7Pit

PWR

PWR

PWR

EXISTING PRECINCT 7.2ARR&A # B578AYCA-2RECL1

P100

P5047.0

53

59

52

41 64

144

153

154

162

167139

36

31 74

129

134 172

177

179

26

79

EL (Y

ELLO

W)

EL (YE

LLOW

)

180

125

22

17

119

185

190

87

114

12

195

92

109

97

7

103

8

1

104

EL (Y

ELLO

W)

EL (YELLOW)

PIT-033

5

P100

68.5

P100

41.5

P100

73

P100

34.7

P50

20.2

P50

32

P100

27.2

P10011.3

P100

14.5

BILL OF MATERIAL

PITSSIZE2589

QTYDUCTS

SIZE QTY MTRSP100P50P23

TOTAL NUMBER OF PITS:TOTAL NUMBER OF CONDUITS:TOTAL LENGTH OF CONDUITS:

NO OF LOTS:

62160

31 936.28 18856 196

33951320.2

54

DRAWING TITLE:

PROJECT No:

SCALE SHEET No. REV.

QUALITY RECORD :

APPROVED

NBNCO APPROVAL RECORD:

DD

AB

WD

REV DATE DESCRIPTION

SIGNATURE DATE

CADREF No:

NN KEY PLAN

OF

LimitedFSA:

STATE: REGION:

FSAM:

DRAFTER

FDA:

**ATTENTION** CONSTRUCTORSDO NOT change or alter job

specifications unless first checkingwith designer.

MAP1

MAP3 MAP4

MAP2

SHEET1

1 2 3 4 5 6 7 8 9 10 11 12

1 2 3 4 5 6 7 8 9 10 11 12

A

B

C

D

E

F

G

H

A

B

C

D

E

F

G

H

Stafford, QLD 4053204/6 Babarra Street

Fax: (07) 3872 5566Tel: (07) 3872 5555

E: rr@robrus.com.au& ASSOCIATES PTY. LTD.

Robin

Russell

CONSULTING ENGINEERS - ELECTRICAL

www.robrus.com.au

A.B.N. 78 010 589 661ACCURATE OR COMPLETE.

IT SHOULD NOT BE SCALED TO LOCATE NBNCO ASSETS.

USE OF NBNCO LIMITED (ABN 86 136 533 741)THIS DOCUMENT HAS BEEN PREPARED SOLELY FOR THE

NBNCO DISCLAIMER

NO WARRANTY IS GIVEN THAT THE INFORMATION IS

FOR USE IN MAINTAINING NBNCO FACILITIES.IT HAS NOT BEEN CREATED FOR ANY OTHER USE.

GAINSBOROUGH GREENS PRECINCT 7.2AYAWALPAH ROADPIMPAMA

QLD

AYCA-2RECL1

B578

1:1000 1 1 E

A 04/12/2015 SHANE MILLS ORIGINAL K.R.

B 22/02/2016 SHANE MILLS FDH ADDED TO STAGE K.R.

C 08/09/2016 SHANE MILLS REVISED ZERO LOT BOUNDARIES K.R.

D 18/02/2017 SHANE MILLS REVISED CIVIL BASE K.R.

E 07/12/2017 A.C. AS BUILT S.M.

LEGEND: NBN CONDUITS & PITS

Fibre Distribution Hub (FDH) site - 1m x 1m

Fibre Access Node (FAN) site

Local Network PitPremises Connection (Houses an MPT)Boundary PitCross-Road & Other Premises Connection (No MPT)Local Network Connection PitPremises Connection & Fibre Splice ClosureDistribution Pitat entry/exit to estate; @ 250m ccs on distribution conduit

Fibre Distribution Hub (FDH) PitWithin 5m of FDH Site

FAN(2ARM)

Marker Post(Post to be numbered)

FDH-ID576

RC183A 22 Multi Dwelling Unit (MDU)

Descriptor Box(Description of type of work & Quantity involved)

DESCQTY

T Existing Telstra conduit trench layout(Proposed conduit indicated for comms cable)

Existing or proposed Energex pole (& pole ID)ID-001

Existing Telstra Exchange

Existing Telstra Pits (size 2,3,4,5,6,7,8 or 9)

Existing Telstra Manholes (Access Chambers)

Existing Traffic Signals Box

Existing network item to be removed/replaced

TransformerPad Mount / Pole Mount

PWR

Depth over alignment indicator(used with every Marker Post)

Proposed 100mm Main Conduit

Proposed 23mm Service Drop

TRF

Proposed shared trench

Proposed 50mm Lateral Conduit

Proposed length of bored conduit

Service Drop Access Pit

Existing NBN 100mm conduit

Existing Telstra P100 conduit

DEPTH-ALIGN -_._

_._

5

M01

PIT-XXX2

PIT-XXX5

PIT-XXX5

PIT-XXX8

PIT-XXX8

PIT-XXX9

P100 40

P50 25

P23 7

'C' communications marker plate

COM

1200mm

LV

A

B

GROUND LEVEL

SECTION VIEW

TAPE

LOCATION A

MINIMUM CONDUIT DEPTH *

Verge 450mm

Local Road 600mm

DTMR Road 800mm

B

750mm

Energex 800mm; Ergon 900mm

LV

100m

m

SHARED TRENCH DETAIL-NBN

PROP

ERTY

BOU

NDAR

Y

* supercedes Energex/Ergon requirements

PIT

PIT

Property Boundary

Kerb

ROAD

NO PITS IN THE SHADED AREA

MIN. 3m MIN. 1m

MIN.

1mMI

N. 3m

ROADFOOTPATH

AS CONSTRUCTED

PIT-0028

PIT-0038

PIT-0048

PIT-0055

PIT-0062

PIT-0072

PIT-0085PIT-0092PIT-0105

PIT-0112PIT-0125

PIT-0138

PIT-0148

PIT-0158

PIT-0165

PIT-0175

PIT-0185

PIT-01

92

PIT-0205

PIT-0218

PIT-0225

PIT-0235

PIT-0245

PIT-0252

PIT-0265

PIT-0272

PIT-0282

PIT-02

98

PIT-0308

PIT-0315

PIT-0335

PIT-0348

PIT-0355

PIT-0368

PIT-0375

PIT-0388

PIT-0395

PIT-0405

PIT-0415

PIT-0428

PIT-0435

PIT-0442 PIT-0455

PIT-0462 PIT-

0475

PIT-0485

PIT-0492

PIT-0505

PIT-0518

P100 17.0

P10019.1

P100

54.5

P100

35.1

P100

24.6

P100

38.5

P100

42.9

P100

52.6

P100

27.8

P10012.2

P100

42.2

P100

27.7

P100

33.7

P100

33.6

P100

26.0

P100

33.5

P100

35.5

P100

24.7

P100

40.0

P50

28.1

P10012.4

P100

26.2

P5017.3

P100

26.2

1035

1036

1037

1038

1039

1040

1041

1047

1042

1043

1044

1045

1046

1048

1049

1050

1051

1052

1053

1023

1024

1025

1026

1027

1028

1029

1030

1031

1032

1033

1034

1014

1015

1016

1017

1018

1019

1020

1021

1022

1054

1055

1056

1057

1058

1059

1060

1061

1062

1063

1064

1065

1066

1067

1091

1092

1093

1094

1095

1096

1097

1098

1099

1100

1101

1102

1103

1104

1105

1106

1113

1128

1114

1115

1116

1117

PWR

PWR

PIT-0528

P100

21.6

P100 35.9

P203.0

P203.0

P203.0

P203.0

P203.0

P203.0

P203.0

P203.0

P2014.0

P203.0

P203.0

P203.0

P203.0

P203.0

P203.0

P203.0

P203.0

P203.0

P203.0

P203.0

P203.0

P2013.0

P2017.0

P203.0

P203.0

P206.0

P2017.0

P203.0

P203.0

P203.0

P203.0

P203.0

P203.0

P203.0

P203.0

P2017.0

P203.0

P203.0

P203.0

P203.0

P203.0

P203.0

P203.0

P203.0

P203.0

P203.0

P203.0

P203.0

P203.0

P2011.0

P203.0

P203.0

P203.0

GOLD COAST RAILWAY LINE

GOLD COAST RAILWAY LINE

1231

1232

1233

1234

1235

1236

1237

1238

1239

1108

1107

1112

1111

1110

1109

1118

1127

1126

1119

1120

1125

1124

1123

1121

1122

1129

1130

1131

1132

1133

1134 1140

1141

1142

1143

1144

1145

1149

1148

1147

1082 1076

1075

1083

1084 1074

1073

1085

1086

1072

1071

1087

1088

1070

1069

1089

1090

1068

1150

1139 1135

DUPLEX

DUPLEX

DUPLEX

DUPLEX

5.5mRd-X

ing

STAND ALONE NBNTRENCH - 19m

STAND ALONE NBNTRENCH - 22m

15m

PIT-0539

P1002.0

FDH-XXX

P1005.0

FDH-Cnr

FDH CONDUITCONTRACTOR SHALL INSTALL AND CAP100mm FDH CONDUIT FROM C9 FDH PIT

TO EDGE OF FUTURE FDH PLINTH.NBN CO WILL INSTALL VERTICAL BEND.

CIVIL CONTRACTORPLEASE ENSURE A 1m x 1m FLAT, LEVEL

SITE AT THE BACK OF THE VERGE,FOR THE NBN FIBRE DISTRIBUTION HUB.

GREAT SANDY CCT

GREAT SANDY CCT

MT ROYAL ST

KUMBATINE ST

MOWBRAY ST

GREAT SANDY CCT

BUTTERLEAF CR

BARAKEE ST

GREAT SANDY CCT

KOSCIUSZKO CCTKOSCIUSZKO CCT

GOLD COAST RAILWAY LINE

GOLD COAST RAILWAY LINE

MEBBIN ST

GREAT SANDY CCT

BUTTERLEAF CR

CONIMBLA ST

KOSCIUSZKO CCT

MEBBIN ST

KOSCIUSZKO CCT

P50

19.3

P100

23.0

P5017.1

P50 18.6

P50

29.8

P50

34.8

P5017.2

P50

17.6

P100

23.7

P100

34.1

P203.0

P203.0

P203.0

P203.0

P203.0

P203.0

P203.0

P203.0

P203.0

P203.0

P203.0

P203.0

P203.0

P203.0

P2014.0

P203.0

P2016.0

P203.0

P203.0

P203.0

P203.0

P203.0

P203.0

P203.0

P203.0

P203.0

P203.0

P203.0

P203.0

P50

19.2

53

59

52

41 64

144

153

154

162

167139

36

31 74

129

134 172

177

179

26

79

EL (YE

LLOW

)

180

125

22

17

119

185

190

87

114

12

195

92

109

97

7

103

8

1

104

PIT-0585

PIT-0575

PIT-0565

PIT-0558

PIT-0632

PIT-0548

P100

46.8

P5047.

0

P10048.8

P100

63.6

P100

78.8

P100

12.0

P100

41.5

P203.0

P203.0

P203.0

P2012.0

P203.0

P203.0

P203.0

P203.0

P203.0

P203.0

P203.0

P203.0

P1001.0

P1007.0

P100

39.0

P2023.0

PIT-0325

Development InformationDevelopment Name: Developer Company:

Authorised Rep:

Development Adress:

CRM ID: Stage Number:

Phone:E-Mail:

GAINSBOROUGH GREENS MIRVAC PACIFIC P/L

YAWALPAH ROAD, PIMPAMA

AYCA-2RECL1 PRECINCT 7.2A

TOM ALLISON07 3859 5888tom.allison@mirvac.com

P100

63.5

P100

26.5

P100

22.4

P100

27.4

P50

31.8

P100

28.1

P100

26.4

P100

50.3

P100

31.5

P100

45.0

P100

33.6

P100

52.0

P100

47.0

P100

45.3

P100

34.6

P50

39.4

P100

35.9 P100

167.0

P100

27.2

P100

18.0P100

34.6

P50

50.7

P100

25.9

P5021.4

P100

30.5

P100

31.8

P100

40.1

P100

33.6

BILL OF MATERIAL

PITSSIZE2589

QTYDUCTS

SIZE QTY MTRSP100P50P23

TOTAL NUMBER OF PITS:TOTAL NUMBER OF CONDUITS:TOTAL LENGTH OF CONDUITS:

NO OF LOTS:

1231191

67 2102.415 409.379 327.0

631612838.7

76

96

97

98

99

77

78

79

330

PIT-0018

PIT-0028

PIT-0038

P1007.0

P100 17.0

P10019.1

P100

54.5

PIT-0528

P100

21.6

P100 35.9

103

PARK

102

101

88

89

90

91

92

93

94

95

80

81

82

83

84

85

86

87

68

69

70 71

EXISTING STAGE

DO NOT CONNECT TOANY EXISTING PITS OR

CONDUITS.

FLINDERS STGAINSBOROUGH

DRIVE

SALTWATER ST

WRAIGHT ST

KOSCIUSZKO CCT

MEBBIN ST

WRAIGHT ST

MEBBIN ST

PIT-0625

PIT-0615

PIT-0605

PIT-0598

PIT-0585

PIT-0575

PIT-0565

PIT-0558

PIT-0632

P100

48.8

P100

63.6

P100

36.4

P100

78.8

P10017.7

P2012.0

P203.0

P203.0

P203.0

P203.0

P203.0

P203.0

P203.0

P203.0

P203.0

P2014.0

P203.0

P203.0

P203.0

P203.0

P203.0

P203.0

P203.0

P203.0

P2012.0

P1007.0

P2023.0

P100

63.5

P100

26.5

P100

22.4

P100

27.4P100

43.7

P100

28.8

P100

27.0

P5021.4

P100

39.6

ACCURATE OR COMPLETE.

DRAWING TITLE:

PROJECT No:

SCALE SHEET No. REV.

QUALITY RECORD :

APPROVED

NBNCO APPROVAL RECORD:

DD

AB

WD

REV DATE DESCRIPTION

SIGNATURE DATE

IT SHOULD NOT BE SCALED TO LOCATE NBNCO ASSETS.

USE OF NBNCO LIMITED (ABN 86 136 533 741)THIS DOCUMENT HAS BEEN PREPARED SOLELY FOR THE

NBNCO DISCLAIMER

NO WARRANTY IS GIVEN THAT THE INFORMATION IS

FOR USE IN MAINTAINING NBNCO FACILITIES.IT HAS NOT BEEN CREATED FOR ANY OTHER USE.

CADREF No:

NN KEY PLAN

OF

LimitedFSA:

STATE: REGION:

FSAM:

DRAFTER

FDA:

**ATTENTION** CONSTRUCTORSDO NOT change or alter job

specifications unless first checkingwith designer.

MAP1

MAP3 MAP4

MAP2

SHEET1

1 2 3 4 5 6 7 8 9 10 11 12

1 2 3 4 5 6 7 8 9 10 11 12

A

B

C

D

E

F

G

H

A

B

C

D

E

F

G

H

Stafford, QLD 4053204/6 Babarra Street

Fax: (07) 3872 5566Tel: (07) 3872 5555

E: rr@robrus.com.au& ASSOCIATES PTY. LTD.

Robin

Russell

CONSULTING ENGINEERS - ELECTRICAL

www.robrus.com.au

A.B.N. 78 010 589 661

GAINSBOROUGH GREENS PRECINCT 7.2C YAWALPAH ROADPIMPAMA

QLD

AYCA-3QMMPI

B580

1:1000 1 1 C

A 03/10/2016 SHANE MILLS ORIGINAL K.R.

B 21/02/2017 SHANE MILLS REVISED LOT BOUNDARIES 1215-1216 K.R.

C 31/10/2017 A.C. AS BUILT S.M.

LEGEND: NBN CONDUITS & PITS

Fibre Distribution Hub (FDH) site - 1m x 1m

Fibre Access Node (FAN) site

Local Network PitPremises Connection (Houses an MPT)Boundary PitCross-Road & Other Premises Connection (No MPT)Local Network Connection PitPremises Connection & Fibre Splice ClosureDistribution Pitat entry/exit to estate; @ 250m ccs on distribution conduit

Fibre Distribution Hub (FDH) PitWithin 5m of FDH Site

FAN(2ARM)

Marker Post(Post to be numbered)

FDH-ID576

RC183A 22 Multi Dwelling Unit (MDU)

Descriptor Box(Description of type of work & Quantity involved)

DESCQTY

T Existing Telstra conduit trench layout(Proposed conduit indicated for comms cable)

Existing or proposed Energex pole (& pole ID)ID-001

Existing Telstra Exchange

Existing Telstra Pits (size 2,3,4,5,6,7,8 or 9)

Existing Telstra Manholes (Access Chambers)

Existing Traffic Signals Box

Existing network item to be removed/replaced

TransformerPad Mount / Pole Mount

PWR

Depth over alignment indicator(used with every Marker Post)

Proposed 100mm Main Conduit

Proposed 23mm Service Drop

TRF

Proposed shared trench

Proposed 50mm Lateral Conduit

Proposed length of bored conduit

Service Drop Access Pit

Existing NBN 100mm conduit

Existing Telstra P100 conduit

DEPTH-ALIGN -_._

_._

5

M01

PIT-XXX2

PIT-XXX5

PIT-XXX5

PIT-XXX8

PIT-XXX8

PIT-XXX9

P100 40

P50 25

P23 7

'C' communications marker plate

COM

1200mm

LV

A

B

GROUND LEVEL

SECTION VIEW

TAPE

LOCATION A

MINIMUM CONDUIT DEPTH *

Verge 450mm

Local Road 600mm

DTMR Road 800mm

B

750mm

Energex 800mm; Ergon 900mm

LV

100m

m

SHARED TRENCH DETAIL-NBN

PROP

ERTY

BOU

NDAR

Y

* supercedes Energex/Ergon requirements

PIT

PIT

Property Boundary

Kerb

ROAD

NO PITS IN THE SHADED AREA

MIN. 3m MIN. 1m

MIN.

1mMI

N. 3m

ROADFOOTPATH

AS CONSTRUCTED

1174

1179

1180

1181

11821183

1184

1185

1186

1187

1188

1190

1191

1192

1193

1194

1195

1196

1197

1198

1199

1200

1201

1202

1203120412051206

1207

1208

1209

1210

1211

1212

1213

1214

1178

1177

1189

1175

1176

1163

1164

1215

1216

1217

1218

1219

1220

1221

1222

1223

1224

1225

1226

1227

1228

1229

1230

1231

1232

1233

1234

1235

1236

1237

1238

1239

1107

1108

1155

1156

1157

1109

1110

1111

1112

1118

1119

1120

1121

1122

1123

1124

1125

1126

1127

1129

1130

1131

1132

1133

1134

1135

1136

1137

1138

PIT-0175

PIT-01

92

PIT-0205

PIT-0218

PIT-0395

PIT-0405

PIT-0415

PIT-0428

PIT-0535

PIT-0542 PIT-0455

PIT-0462 PIT-

0475

PIT-0485

PIT-0552

PIT-0505

PIT-0518

42.2

P10015.5

P100

33.7

P50

53.0

P100

39.6

P100

24.7

P100

P100

18.2

P100

40.0

P50

28.1

P1001.0

P10012.4

P100

26.2

P5017.3

P100

27.4

P100

26.7

P100

26.2

P100

18.6

P10013.7

P50

29.7

Development InformationDevelopment Name: Developer Company:

Authorised Rep:

Development Adress:

CRM ID: Stage Number:

Phone:E-Mail:

GAINSBOROUGH GREENS MIRVAC PACIFIC P/L

YAWALPAH ROAD, PIMPAMA

AYCA-3QMMPI PRECINCT 7.2C

TOM ALLISON07 3859 5888tom.allison@mirvac.com

P203.0

P203.0

P203.0

P203.0

P203.0

P206.0

P2017.0

P203.0

P203.0

P203.0

P203.0

P203.0

P2017.0

P203.0

P203.0

P203.0

P203.0

P203.0

P203.0

P203.0

P203.0

P203.0

P203.0

P203.0

P203.0

P203.0

P2011.0

P203.0

P203.0

PIT-0539

P1002.0

P1004.7

P100

46.0

P100

24.6

19.2

PIT-00

15

PIT-00

25

PIT-00

35

PIT-00

45

PIT-0

055

PIT-0

065

PIT-0075PIT-00

82

PIT-0098

PIT-0108PIT-0118

PIT-0125

PIT-0132

PIT-0142

PIT-0155

PIT-0495

PIT-0

175

PIT-0

185

PIT-01

95

PIT-02

02

PIT-02

18

PIT-02

25

PIT-0238

PIT-0245

PIT-0252

PIT-0262

PIT-0275

PIT-0288

PIT-0295

PIT-0505

PIT-0315

PIT-0515

P100

19.7

P100

16

P100

31.7

P100

38

P100

39.6

P100

36.8

P100

34.4

P50

35.6P100

47

P100

31.9P100

45.1

P100

67.4

P10017.9

P50

33.5

P100

30

P5018.7

P100

29.3

P1001

P100

49.2

P100

66.3

P1001

P100

13.9

P100

23.6

P100

25.8

P5017.7

P100

27.9

P100

32.2

P1009.6

P100

48.1

P100

37.4

P50

29.3

P10017.3

P100

27.6

P100

16.9

P203

P2010

P203

P203

P203

P203

P203

P203

P203

P203

P203

P203

P203

P2015

P203

P203

P203

P203

P203

P203

P203

P203

P203

P203

P203

P203

P203

P203

P203

P203

P203

P203

P203

P203

P203

P203

P203

P203

P203

P203

P203

P203

P203

P203

P203

P203

P203

P10017.6

P50

30.2

P203

P203

P203

P2012

P203

P203

P203

P203

P203

P203

P203

CONNECT TO EXISTINGNBN CONDUIT

PIT-0015

PIT-0022

PIT-0

035

PIT-0

042

PIT-00

55

PIT-00

62

PIT-00

78

PIT-00

85

PIT-00

95

PIT-01

05

PIT-0

115

PIT-0

122

PIT-0

135

PIT-0

145

PIT-0

152

PIT-0

165

PIT-0175

PIT-0185

PIT-0195

PIT-0205

PIT-0

215

PIT-0

222

PIT-0

235

PIT-0

242

PIT-0255

PIT-02

65

PIT-02

75

PIT-02

82PIT

-030

8

PIT-0315

PIT-03

25

PIT-0

335

PIT-0

345

PIT-03

52

PIT-0365PIT-0372

PIT-03

8

8

PIT-03

9

5

PIT-04

02

PIT-0415

PIT-04

2

2

PIT-0435

PIT-0445

PIT-0452

PIT-0462

P50

36.4

P5017.4

P5020.2

P100

27.8

P5021.1

P100

21.8

P100

22.4

P100 27.9

P50

18.2

P10029.2

P100

19

P100

28.8

P50

21.4

P100

28.3

P100

66

P100

39

P5018.1

P100

44.4

PIT-0475

P100

47.8

P100

24.3

P100

41.7

P100

24.1

P100

25.4

P100

24.6

PIT-0485

P50

36.4

P100

26.4

P50 19.8

P203

P203

P203

P203

P203

P203

P203

P203

P203

P203

P203

P203

P203

P203

P203P20

3

P203

P203

P203

P203

P203

P203

P203

P203

P203

P203

P203

P203

P2014

P203

P2014

P203

P203

P203

P203

P203

P203

P2016 P20

3

P203

P203

P203

P203

P203

P203

P203

P2016

P203

P203

P203

P203

P203

P203

P203

P203

P203

P203

P2016

P203

P203

P203

P203

P203

P203

P203

P203

P203

P203

P203

P203

P203

P203

P203

P203

P203

P2020

P203

P203

P203

P203

P203

P203

P203

P203

P203

P203

P203

P203

P203

PIT-0525 P203

P100

43.9

P50

33.6

P203

P2020

P203

PWR

PWR

105310531061

1062

1063

1064

1065

1066

1067

1091

1092

1093

1094

1095

1096

1097

1098

1099

1100

1101

1106

1113

1128

1114

1115

1116

1117

1068

1069

1070

1071

1072

1073

1074

1075

1076

1077

1078

1079

1172

1173

1174

1165

1166

1167

1158

1159

1160

1161

1162

1146

1147

1148

1149

1082

1083

1084

1085

1086

1087

1088

1089

1090

1139

1140

1141

1142

1143

1144

1145

1150

1151

1152

1153

1154

1168

1169

1170

1171

1080

1081

CONNECT TO EXISTINGNBN CONDUIT

CONNECT TO EXISTINGNBN CONDUIT

CONNECT TO EXISTINGNBN CONDUIT

CONNECT TO EXISTINGNBN CONDUIT

CONNECT TO EXISTINGNBN CONDUIT

CONNECT TO EXISTINGNBN CONDUIT

FDH-XXX

CONIMBLA

BUTTERFEAF CR

BARAKEE ST

BUTTERFEAF CR

GREAT

SANDY CCT

GREAT SANDY CCT

GREAT SANDY CCT

GREAT SANDY CCT

TOONUMBA ST

BUTTERLE

AF CRNANGAR ST

NANGAR ST

BUTTERFEAF CR

ST

GREAT SANDY CCT

GREAT SANDY CCT

GREAT SANDY CCT

GREAT SANDY CCT

SUND

OWN

CCT

SUND

OWN

CCT

(DUPLEX)

(DUPLEX)

906

DUPLEX

DUPLEX

DUPLEX

EXISTING PRECINCT 7.2ARR&A # B578AYCA-2RECL1

EXISTING PRECINCT 7.2BRR&A # B579AYCA-3QMMOS

STAND ALONE NBNTRENCH - 18m

@ 3m ALIGNMENT.

STAND ALONE NBNTRENCH - 26m

@ 3m ALIGNMENT.

STAND ALONE NBNTRENCH - 29m

@ 3m ALIGNMENT.

P203

P10015.3

P10013.8

P100

41

P50

13.1

P100

45.4

P100

49.8

P5035

P100

40.5

P50

36.6

P100

34.2

P100

24.1

P1009.3

P50

28.4

P100

16.2

P100

23.4

P100

16.6

P100

23.8

P100

63.1

P100

41.9

P5018.7

P100

36.4

P100

24.7

P10025.5

P100

34.1

P100

36.6

BILL OF MATERIAL

PITSSIZE2589

QTYDUCTS

SIZE QTY MTRSP100P50P23

TOTAL NUMBER OF PITS:TOTAL NUMBER OF CONDUITS:TOTAL LENGTH OF CONDUITS:

NO OF LOTS:

143230

38 1192.115 374.498 397

491511963.5

96

top related