SPECIFICATION FOR ARMSTRONG CEILINGS – FINE FISSURED
BUTT EDGE WITH XL 24MM GRID
Providing and fixing in true horizontal level 600 mm. X 600 mm. false ceiling
system manufactured by M/s. Armstrong World Industries using hot dipped
galvanized steel section, exposed surface with pre-coated capping, main tee
of size 24 x 32 mm., having 0.27 mm gauge at every 1200 mm. centre to
centre maximum and rotary stitched cross tee of size 24 x 27 mm, having
0.27 mm gauge at every 600 mm. c/c. and sub cross tee of size 24 x 27 mm,
having 0.25 mm gauge at 1200 mm c/c. and wall angle of size 19 x 19 mm.,
having 0.35 mm gauge fixed to the periphery of the wall. The above grid is
suspended at every 1200mm c/c. in both directions using 2.0 mm. thick pre-
straightened GI wire laying FINE FISSURED BUTT Edge ceiling tiles
manufactured by M/s. Armstrong World Industries, of size
600mmx600mmx15mm having NRC 0.55, Light reflectance of >84% (WT),
thermal conductivity k = 0.052-0.057 W/m0K, Humidity Resistance of 99% ,
having Fire Performance CLASS O / CLASS 1 (BS 476), surface having 3
coats of white paint with Fine Fissured, back of the tile duly sanded and
finished with a coat of protective paint over the formed grid complete.
SPECIFICATION FOR ARMSTRONG CEILINGS – FINE FISSURED
TEGULAR EDGE WITH XL 24MM GRID
Providing and fixing in true horizontal level 600 mm. X 600 mm. false ceiling
system manufactured by M/s. Armstrong World Industries using hot dipped
galvanized steel section, exposed surface with pre-coated capping, main tee
of size 24 x 32 mm., having 0.27 mm gauge at every 1200 mm. centre to
centre maximum and rotary stitched cross tee of size 24 x 27 mm, having
0.27 mm gauge at every 600 mm. c/c. and sub cross tee of size 24 x 27 mm,
having 0.25 mm gauge at 1200 mm c/c. and wall angle of size 19 x 19 mm.,
having 0.35 mm gauge fixed to the periphery of the wall. The above grid is
suspended at every 1200mm c/c. in both directions using 2.0 mm. thick pre-
straightened GI wire laying FINE FISSURED TEGULAR Edge ceiling tiles
manufactured by M/s. Armstrong World Industries, of size
600mmx600mmx15mm having NRC 0.55, Light reflectance of >84% (WT),
thermal conductivity k = 0.052-0.057 W/m0K, Humidity Resistance of 99% ,
having Fire Performance CLASS O / CLASS 1 (BS 476), surface having 3
coats of white paint with Fine Fissured, back of the tile duly sanded and
finished with a coat of protective paint over the formed grid complete
SPECIFICATION FOR ARMSTRONG CEILINGS – FINE FISSURED
MICROLOOK EDGE WITH XL 15MM GRID
Providing and fixing in true horizontal level 600 mm. X 600 mm. false ceiling
system manufactured by M/s. Armstrong World Industries using hot dipped
galvanized steel section, exposed surface with pre-coated capping, main tee
of size 15 x 32 mm., having 0.27 mm gauge at every 1200 mm. centre to
centre maximum and rotary stitched cross tee of size 15 x 32 mm, having
0.27 mm gauge at every 600 mm. c/c. and sub cross tee of size 15 x 32 mm,
having 0.25 mm gauge at 1200 mm c/c. and wall angle of size 19 x 19 mm.,
having 0.35 mm gauge fixed to the periphery of the wall. The above grid is
suspended at every 1200mm c/c. in both directions using 2.0 mm. thick pre-
straightened GI wire laying FINE FISSURED MICROLOOK Edge ceiling
tiles manufactured by M/s. Armstrong World Industries, of size
600mmx600mmx15mm having NRC 0.55, Light reflectance of >84% (WT),
thermal conductivity k = 0.052-0.057 W/m0K, Humidity Resistance of 99% ,
having Fire Performance CLASS O / CLASS 1 (BS 476), surface having 3
coats of white paint with Fine Fissured, back of the tile duly sanded and
finished with a coat of protective paint over the formed grid complete
SPECIFICATION FOR ARMSTRONG CEILINGS – FINE FISSURED
MICROLOOK EDGE WITH SILHOUETTE GRID (BLACK REVEAL)
Providing and fixing false ceiling system manufactured by M/s. Armstrong
World Industries using hot dipped galvanized steel section, rotary stitched
main tee of size 15mm x 42 mm web height, having 0.36 mm gauge at every
600 mm centre to centre maximum and rotary stitched cross tee of size 15
mm x 42 mm, having 0.33 mm gauge at every 600 mm. c/c. and wall angle of
size 19 x 19 mm., having 0.35 mm gauge fixed to the periphery of the wall.
The above grid is suspended at every 600mm c/c. in both directions using 2.0
mm. thick pre-straightened GI wire laying FINE FISSURED MICROLOOK
WITH SILHOUETTE GRID(BLACK REVEAL) ceiling tiles manufactured by
M/s. Armstrong World Industries, of size 600mmx600mmx15mm having NRC
0.55, Light reflectance of >84% (WT), thermal conductivity k = 0.052-0.057
W/m0K, Humidity Resistance of 99% , having Fire Performance CLASS O /
CLASS 1 (BS 476), surface having 3 coats of white paint with Fine Fissured,
back of the tile duly sanded and finished with a coat of protective paint over
the formed grid complete
SPECIFICATION FOR ARMSTRONG CEILINGS – FINE FISSURED
MICROLOOK EDGE WITH SILHOUETTE GRID (WHITE REVEAL)
Providing and fixing false ceiling system manufactured by M/s. Armstrong
World Industries using hot dipped galvanized steel section, rotary stitched
main tee of size 15mm x 42 mm web height, having 0.36 mm gauge at every
600 mm centre to centre maximum and rotary stitched cross tee of size 15
mm x 42 mm, having 0.33 mm gauge at every 600 mm. c/c. and wall angle of
size 19 x 19 mm., having 0.35 mm gauge fixed to the periphery of the wall.
The above grid is suspended at every 600mm c/c. in both directions using 2.0
mm. thick pre-straightened GI wire laying fine fissured microlook with
silhouette grid(white reveal) ceiling tiles manufactured by M/s. Armstrong
World Industries, of size 600mmx600mmx15mm having NRC 0.55, Light
reflectance of >84% (WT), thermal conductivity k = 0.052-0.057 W/m0K,
Humidity Resistance of 99% , having Fire Performance CLASS O / CLASS 1
(BS 476), surface having 3 coats of white paint with Fine Fissured, back of
the tile duly sanded and finished with a coat of protective paint over the
formed grid complete
SPECIFICATION FOR ARMSTRONG CEILINGS – FINE FISSURED
BUTT EDGE WITH 24MM SELECT GRID
Providing and fixing in true horizontal level 600 mm X 600 mm false ceiling
system manufactured by M/s. Armstrong World Industries using hot dipped
galvanized steel section, rotary stitched main tee of size 24 mm x 30 mm
web height, having 0.27 mm gauge at every 600 mm centre to centre
maximum and rotary stitched cross tee of size 24 mm x 30 mm, having 0.27
mm gauge at every 600 mm. c/c. and wall angle of size 19 x 19 mm., having
0.35 mm gauge fixed to the periphery of the wall. The above grid is
suspended at every 600mm c/c. in both directions using 2.0 mm. thick pre-
straightened GI wire laying fine fissured butt edge with 24mm select grid
manufactured by M/s. Armstrong World Industries, of size
600mmx600mmx15mm having NRC 0.55, Light reflectance of >84% (WT),
thermal conductivity k = 0.052-0.057 W/m0K, Humidity Resistance of 99% ,
having Fire Performance CLASS O / CLASS 1 (BS 476), surface having 3
coats of white paint with Fine Fissured, back of the tile duly sanded and
finished with a coat of protective paint over the formed grid complete
SPECIFICATION FOR ARMSTRONG CEILINGS – FINE FISSURED
TEGULAR EDGE WITH 24MM SELECT GRID
Providing and fixing in true horizontal level 600 mm X 600 mm false ceiling
system manufactured by M/s. Armstrong World Industries using hot dipped
galvanized steel section, rotary stitched main tee of size 24 mm x 30 mm
web height, having 0.27 mm gauge at every 600 mm centre to centre
maximum and rotary stitched cross tee of size 24 mm x 30 mm, having 0.27
mm gauge at every 600 mm. c/c. and wall angle of size 19 x 19 mm., having
0.35 mm gauge fixed to the periphery of the wall. The above grid is
suspended at every 600mm c/c. in both directions using 2.0 mm. thick pre-
straightened GI wire laying fine fissured tegular edge with xl 24mm select
grid ceiling tiles manufactured by M/s. Armstrong World Industries, of size
600mmx600mmx15mm having NRC 0.55, Light reflectance of >84% (WT),
thermal conductivity k = 0.052-0.057 W/m0K, Humidity Resistance of 99% ,
having Fire Performance CLASS O / CLASS 1 (BS 476), surface having 3
coats of white paint with Fine Fissured, back of the tile duly sanded and
finished with a coat of protective paint over the formed grid complete
SPECIFICATION FOR ARMSTRONG CEILINGS – FINE FISSURED
BUTT EDGE WITH 15MM SELECT GRID
Providing and fixing in true horizontal level 600 mm X 600 mm false ceiling
system manufactured by M/s. Armstrong World Industries using hot dipped
galvanized steel section, rotary stitched main tee of size 15 mm x 30 mm
web height, having 0.27 mm gauge at every 600 mm centre to centre
maximum and rotary stitched cross tee of size 15 mm x 30 mm, having 0.27
mm gauge at every 600 mm. c/c. and wall angle of size 19 x 19 mm., having
0.35 mm gauge fixed to the periphery of the wall. The above grid is
suspended at every 600mm c/c. in both directions using 2.0 mm. thick pre-
straightened GI wire laying Fine Fissured Butt Edge with 15mm Select Grid
ceiling tiles manufactured by M/s. Armstrong World Industries, of size
600mmx600mmx15mm having NRC 0.55, Light reflectance of >84% (WT),
thermal conductivity k = 0.052-0.057 W/m0K, Humidity Resistance of 99% ,
having Fire Performance CLASS O / CLASS 1 (BS 476), surface having 3
coats of white paint with Fine Fissured, back of the tile duly sanded and
finished with a coat of protective paint over the formed grid complete
SPECIFICATION FOR ARMSTRONG CEILINGS – DUNE SUPREME BUTT
EDGE WITH XL 24MM GRID
Providing and fixing in true horizontal level 600 mm. X 600 mm. false ceiling
system manufactured by M/s. Armstrong World Industries using hot dipped
galvanized steel section, exposed surface with pre-coated capping, main tee
of size 24 x 32 mm., having 0.27 mm gauge at every 1200 mm. centre to
centre maximum and rotary stitched cross tee of size 24 x 27 mm, having
0.27 mm gauge at every 600 mm. c/c. and sub cross tee of size 24 x 27 mm,
having 0.25 mm gauge at 1200 mm c/c. and wall angle of size 19 x 19 mm.,
having 0.35 mm gauge fixed to the periphery of the wall. The above grid is
suspended at every 1200mm c/c. in both directions using 2.0 mm. thick pre-
straightened GI wire laying laying Dune Supreme Butt Edge ceiling tiles
manufactured by M/s. Armstrong World Industries, of size
600mmx600mmx15mm having NRC 0.50, Light reflectance of >85% (WT),
thermal conductivity k = 0.052-0.057 W/m0K, Humidity Resistance of 99%
(having LIFETIME GUARANTEE against SAG), having Fire Performance
CLASS O / CLASS 1 (BS 476), surface having 3 coats of white paint - crisp
finely granulated with microperforations, back of the tile duly sanded and
finished with a coat of protective paint over the formed grid complete.
SPECIFICATION FOR ARMSTRONG CEILINGS – DUNE SUPREME
TEGULAR EDGE WITH XL 24MM GRID
Providing and fixing in true horizontal level 600 mm. X 600 mm. false ceiling
system manufactured by M/s. Armstrong World Industries using hot dipped
galvanized steel section, exposed surface with pre-coated capping, main tee
of size 24 x 32 mm., having 0.27 mm gauge at every 1200 mm. centre to
centre maximum and rotary stitched cross tee of size 24 x 27 mm, having
0.27 mm gauge at every 600 mm. c/c. and sub cross tee of size 24 x 27 mm,
having 0.25 mm gauge at 1200 mm c/c. and wall angle of size 19 x 19 mm.,
having 0.35 mm gauge fixed to the periphery of the wall. The above grid is
suspended at every 1200mm c/c. in both directions using 2.0 mm. thick pre-
straightened GI wire laying Dune Supreme Tegular Edge ceiling tiles
manufactured by M/s. Armstrong World Industries, of size
600mmx600mmx15mm having NRC 0.50, Light reflectance of >85% (WT),
thermal conductivity k = 0.052-0.057 W/m0K, Humidity Resistance of 99%
(having LIFETIME GUARANTEE against SAG), having Fire Performance
CLASS O / CLASS 1 (BS 476), surface having 3 coats of white paint - crisp
finely granulated with micro-perforations, back of the tile duly sanded and
finished with a coat of protective paint over the formed grid complete.
SPECIFICATION FOR ARMSTRONG CEILINGS – DUNE SUPREME
MICROLOOK EDGE WITH XL 15MM GRID
Providing and fixing in true horizontal level 600 mm. X 600 mm. false ceiling
system manufactured by M/s. Armstrong World Industries using hot dipped
galvanized steel section, exposed surface with pre-coated capping, main tee
of size 15 x 32 mm., having 0.27 mm gauge at every 1200 mm. centre to
centre maximum and rotary stitched cross tee of size 15 x 32 mm, having
0.27 mm gauge at every 600 mm. c/c. and sub cross tee of size 15 x 32 mm,
having 0.25 mm gauge at 1200 mm c/c. and wall angle of size 19 x 19 mm.,
having 0.35 mm gauge fixed to the periphery of the wall. The above grid is
suspended at every 1200mm c/c. in both directions using 2.0 mm. thick pre-
straightened GI wire laying DUNE SUPREME MICROLOOK EDGE ceiling
tiles manufactured by M/s. Armstrong World Industries, of size
600mmx600mmx15mm having NRC 0.50, Light reflectance of >85% (WT),
thermal conductivity k = 0.052-0.057 W/m0K, Humidity Resistance of 99%
(having LIFETIME GUARANTEE against SAG), having Fire Performance
CLASS O / CLASS 1 (BS 476), surface having 3 coats of white paint - crisp
finely granulated with microperforations, back of the tile duly sanded and
finished with a coat of protective paint over the formed grid complete.
SPECIFICATION FOR ARMSTRONG CEILINGS – DUNE SUPREME
MICROLOOK EDGE WITH SILHOUETTE GRID(BLACK REVEAL)
Providing and fixing false ceiling system manufactured by M/s. Armstrong
World Industries using hot dipped galvanized steel section, rotary stitched
main tee of size 15mm x 42 mm web height, having 0.36 mm gauge at every
600 mm centre to centre maximum and rotary stitched cross tee of size 15
mm x 42 mm, having 0.33 mm gauge at every 600 mm. c/c. and wall angle of
size 19 x 19 mm., having 0.35 mm gauge fixed to the periphery of the wall.
The above grid is suspended at every 600mm c/c. in both directions using 2.0
mm. thick pre-straightened GI wire laying DUNE SUPREME MICROLOOK
EDGE WITH SILHOUETTE GRID(BLACK REVEAL) ceiling tiles
manufactured by M/s. Armstrong World Industries, of size
600mmx600mmx15mm having NRC 0.50, Light reflectance of >85% (WT),
thermal conductivity k = 0.052-0.057 W/m0K, Humidity Resistance of 99%
(having LIFETIME GUARANTEE against SAG), having Fire Performance
CLASS O / CLASS 1 (BS 476), surface having 3 coats of white paint - crisp
finely granulated with microperforations, back of the tile duly sanded and
finished with a coat of protective paint over the formed grid complete.
SPECIFICATION FOR ARMSTRONG CEILINGS – DUNE SUPREME
MICROLOOK EDGE WITH SILHOUETTE GRID(WHITE REVEAL)
Providing and fixing false ceiling system manufactured by M/s. Armstrong
World Industries using hot dipped galvanized steel section, rotary stitched
main tee of size 15mm x 42 mm web height, having 0.36 mm gauge at every
600 mm centre to centre maximum and rotary stitched cross tee of size 15
mm x 42 mm, having 0.33 mm gauge at every 600 mm. c/c. and wall angle of
size 19 x 19 mm., having 0.35 mm gauge fixed to the periphery of the wall.
The above grid is suspended at every 600mm c/c. in both directions using 2.0
mm. thick pre-straightened GI wire laying DUNE SUPREME MICROLOOK
EDGE WITH SILHOUETTE GRID(WHITE REVEAL) ceiling tiles
manufactured by M/s. Armstrong World Industries, of size
600mmx600mmx15mm having NRC 0.50, Light reflectance of >85% (WT),
thermal conductivity k = 0.052-0.057 W/m0K, Humidity Resistance of 99%
(having LIFETIME GUARANTEE against SAG), having Fire Performance
CLASS O / CLASS 1 (BS 476), surface having 3 coats of white paint - crisp
finely granulated with microperforations, back of the tile duly sanded and
finished with a coat of protective paint over the formed grid complete.
SPECIFICATION FOR ARMSTRONG CEILINGS – DUNE SUPREME
MICROLOOK EDGE WITH XL 24MM SELECT GRID
Providing and fixing in true horizontal level 600 mm X 600 mm false ceiling
system manufactured by M/s. Armstrong World Industries using hot dipped
galvanized steel section, rotary stitched main tee of size 24 mm x 30 mm
web height, having 0.27 mm gauge at every 600 mm centre to centre
maximum and rotary stitched cross tee of size 24 mm x 30 mm, having 0.27
mm gauge at every 600 mm. c/c. and wall angle of size 19 x 19 mm., having
0.35 mm gauge fixed to the periphery of the wall. The above grid is
suspended at every 600mm c/c. in both directions using 2.0 mm. thick pre-
straightened GI wire laying DUNE SUPREME MICROLOOK EDGE WITH XL
24MM SELECT GRID ceiling tiles manufactured by M/s. Armstrong World
Industries, of size 600mmx600mmx15mm having NRC 0.50, Light
reflectance of >85% (WT), thermal conductivity k = 0.052-0.057 W/m0K,
Humidity Resistance of 99% (having LIFETIME GUARANTEE against SAG),
having Fire Performance CLASS O / CLASS 1 (BS 476), surface having 3
coats of white paint - crisp finely granulated with microperforations, back of
the tile duly sanded and finished with a coat of protective paint over the
formed grid complete
SPECIFICATION FOR ARMSTRONG CEILINGS – DUNE SUPREME BUTT
EDGE WITH 15MM SELECT GRID
Providing and fixing in true horizontal level 600 mm X 600 mm false ceiling
system manufactured by M/s. Armstrong World Industries using hot dipped
galvanized steel section, rotary stitched main tee of size 15 mm x 30 mm
web height, having 0.27 mm gauge at every 600 mm centre to centre
maximum and rotary stitched cross tee of size 15 mm x 30 mm, having 0.27
mm gauge at every 600 mm. c/c. and wall angle of size 19 x 19 mm., having
0.35 mm gauge fixed to the periphery of the wall. The above grid is
suspended at every 600mm c/c. in both directions using 2.0 mm. thick pre-
straightened GI wire laying DUNE SUPREME BUTT EDGE WITH 15MM
SELECT GRID ceiling tiles manufactured by M/s. Armstrong World
Industries, of size 600mmx600mmx15mm having NRC 0.50, Light
reflectance of >85% (WT), thermal conductivity k = 0.052-0.057 W/m0K,
Humidity Resistance of 99% (having LIFETIME GUARANTEE against SAG),
having Fire Performance CLASS O / CLASS 1 (BS 476), surface having 3
coats of white paint - crisp finely granulated with micro-perforations, back
of the tile duly sanded and finished with a coat of protective paint over the
formed grid complete.
SPECIFICATION FOR ARMSTRONG CEILINGS – FISSURED ANF RH 90
BUTT EDGE WITH XL 24MM GRID
Providing and fixing in true horizontal level 600 mm. X 600 mm. false ceiling
system manufactured by M/s. Armstrong World Industries using hot dipped
galvanized steel section, exposed surface with pre-coated capping, main tee
of size 24 x 32 mm., having 0.27 mm gauge at every 1200 mm. centre to
centre maximum and rotary stitched cross tee of size 24 x 27 mm, having
0.27 mm gauge at every 600 mm. c/c. and sub cross tee of size 24 x 27 mm,
having 0.25 mm gauge at 1200 mm c/c. and wall angle of size 19 x 19 mm.,
having 0.35 mm gauge fixed to the periphery of the wall. The above grid is
suspended at every 1200mm c/c. in both directions using 2.0 mm. thick pre-
straightened GI wire laying FISSURED ANF BUTT Edge ceiling tiles
manufactured by M/s. Armstrong World Industries, of size
600mmx600mmx14mm having NRC 0.5, Light reflectance of >80% (WT),
thermal conductivity k = 0.052-0.057 W/m0K, Humidity Resistance of 90% ,
having Fire Performance CLASS O / CLASS 1 (BS 476), surface having
Random Fissured with 3 coats of white paints and finished with a coat of
protective paint over the formed grid complete.
SPECIFICATION FOR ARMSTRONG CEILINGS – FISSURED ANF RH 90
TEGULAR EDGE WITH XL 24MM GRID
Providing and fixing in true horizontal level 600 mm. X 600 mm. false ceiling
system manufactured by M/s. Armstrong World Industries using hot dipped
galvanized steel section, exposed surface with pre-coated capping, main tee
of size 24 x 32 mm., having 0.27 mm gauge at every 1200 mm. centre to
centre maximum and rotary stitched cross tee of size 24 x 27 mm, having
0.27 mm gauge at every 600 mm. c/c. and sub cross tee of size 24 x 27 mm,
having 0.25 mm gauge at 1200 mm c/c. and wall angle of size 19 x 19 mm.,
having 0.35 mm gauge fixed to the periphery of the wall. The above grid is
suspended at every 1200mm c/c. in both directions using 2.0 mm. thick pre-
straightened GI wire laying FISSURED ANF TEGULAR Edge ceiling tiles
manufactured by M/s. Armstrong World Industries, of size
600mmx600mmx14mm having NRC 0.5, Light reflectance of >80% (WT),
thermal conductivity k = 0.052-0.057 W/m0K, Humidity Resistance of 90% ,
having Fire Performance CLASS O / CLASS 1 (BS 476), surface having
Random Fissured with 3 coats of white paints and finished with a coat of
protective paint over the formed grid complete.
SPECIFICATION FOR ARMSTRONG CEILINGS – FISSURED ANF RH 90
TEGULAR EDGE WITH XL 24MM GRID.
Providing and fixing in true horizontal level 600 mm X 600 mm false ceiling
system manufactured by M/s. Armstrong World Industries using hot dipped
galvanized steel section, rotary stitched main tee of size 24 mm x 30 mm
web height, having 0.27 mm gauge at every 600 mm centre to centre
maximum and rotary stitched cross tee of size 24 mm x 30 mm, having 0.27
mm gauge at every 600 mm. c/c. and wall angle of size 19 x 19 mm., having
0.35 mm gauge fixed to the periphery of the wall. The above grid is
suspended at every 600mm c/c. in both directions using 2.0 mm. thick pre-
straightened GI wire laying FISSURED ANF TEGULAR Edge ceiling tiles
manufactured by M/s. Armstrong World Industries, of size
600mmx600mmx14mm having NRC 0.5, Light reflectance of >80% (WT),
thermal conductivity k = 0.052-0.057 W/m0K, Humidity Resistance of 90% ,
having Fire Performance CLASS O / CLASS 1 (BS 476), surface having
Random Fissured with 3 coats of white paints and finished with a coat of
protective paint over the formed grid complete.
SPECIFICATION FOR ARMSTRONG CEILINGS – FISSURED ANF BUTT
WITH SELECT 15 MM GRID.
Providing and fixing in true horizontal level 600 mm X 600 mm false ceiling
system manufactured by M/s. Armstrong World Industries using hot dipped
galvanized steel section, rotary stitched main tee of size 15 mm x 30 mm
web height, having 0.27 mm gauge at every 600 mm centre to centre
maximum and rotary stitched cross tee of size 15 mm x 30 mm, having 0.27
mm gauge at every 600 mm. c/c. and wall angle of size 19 x 19 mm., having
0.35 mm gauge fixed to the periphery of the wall. The above grid is
suspended at every 600mm c/c. in both directions using 2.0 mm. thick pre-
straightened GI wire laying FISSURED ANF BUTT EDGE ceiling tiles
manufactured by M/s. Armstrong World Industries, of size
600mmx600mmx14mm having NRC 0.5, Light reflectance of >80% (WT),
thermal conductivity k = 0.052-0.057 W/m0K, Humidity Resistance of 90% ,
having Fire Performance CLASS O / CLASS 1 (BS 476), surface having
Random Fissured with 3 coats of white paints and finished with a coat of
protective paint over the formed grid complete.
SPECIFICATION FOR ARMSTRONG CEILINGS – PRIMA ADRIA BUTT
EDGE WITH XL 24MM GRID
Providing and fixing in true horizontal level 600 mm. X 600 mm. false ceiling
system manufactured by M/s. Armstrong World Industries using hot dipped
galvanized steel section, exposed surface with pre-coated capping, main tee
of size 24 x 32 mm., having 0.27 mm gauge at every 1200 mm. centre to
centre maximum and rotary stitched cross tee of size 24 x 27 mm, having
0.27 mm gauge at every 600 mm. c/c. and sub cross tee of size 24 x 27 mm,
having 0.25 mm gauge at 1200 mm c/c. and wall angle of size 19 x 19 mm.,
having 0.35 mm gauge fixed to the periphery of the wall. The above grid is
suspended at every 1200mm c/c. in both directions using 2.0 mm. thick pre-
straightened GI wire laying PRIMA ADRIA BUTT Edge ceiling tiles
manufactured by M/s. Armstrong World Industries, of size
600mmx600mmx15mm having NRC 0.5, Light reflectance of >85% (WT),
thermal conductivity k = 0.052-0.057 W/m0K, Humidity Resistance of 95% ,
having Fire Performance CLASS O / CLASS 1 (BS 476), surface having 4
coats of white paint and microperforations and finished with a coat of
protective paint over the formed grid complete.
SPECIFICATION FOR ARMSTRONG CEILINGS – PRIMA ADRIA
TEGULAR EDGE WITH XL 24MM GRID
Providing and fixing in true horizontal level 600 mm. X 600 mm. false ceiling
system manufactured by M/s. Armstrong World Industries using hot dipped
galvanized steel section, exposed surface with pre-coated capping, main tee
of size 24 x 32 mm., having 0.27 mm gauge at every 1200 mm. centre to
centre maximum and rotary stitched cross tee of size 24 x 27 mm, having
0.27 mm gauge at every 600 mm. c/c. and sub cross tee of size 24 x 27 mm,
having 0.25 mm gauge at 1200 mm c/c. and wall angle of size 19 x 19 mm.,
having 0.35 mm gauge fixed to the periphery of the wall. The above grid is
suspended at every 1200mm c/c. in both directions using 2.0 mm. thick pre-
straightened GI wire laying PRIMA ADRIA TEGULAR Edge ceiling tiles
manufactured by M/s. Armstrong World Industries, of size
600mmx600mmx15mm having NRC 0.5, Light reflectance of >85% (WT),
thermal conductivity k = 0.052-0.057 W/m0K, Humidity Resistance of 95% ,
having Fire Performance CLASS O / CLASS 1 (BS 476), surface having 4
coats of white paint and micro-perforations and finished with a coat of
protective paint over the formed grid complete
SPECIFICATION FOR ARMSTRONG CEILINGS – PRIMA ADRIA
MICROLOOK EDGE WITH XL 15MM GRID
Providing and fixing in true horizontal level 600 mm. X 600 mm. false ceiling
system manufactured by M/s. Armstrong World Industries using hot dipped
galvanized steel section, exposed surface with pre-coated capping, main tee
of size 15 x 32 mm., having 0.27 mm gauge at every 1200 mm. centre to
centre maximum and rotary stitched cross tee of size 15 x 32 mm, having
0.27 mm gauge at every 600 mm. c/c. and sub cross tee of size 15 x 32 mm,
having 0.25 mm gauge at 1200 mm c/c. and wall angle of size 19 x 19 mm.,
having 0.35 mm gauge fixed to the periphery of the wall. The above grid is
suspended at every 1200mm c/c. in both directions using 2.0 mm. thick pre-
straightened GI wire laying PRIMA ADRIA MICROLOOK Edge ceiling tiles
manufactured by M/s. Armstrong World Industries, of size
600mmx600mmx15mm having NRC 0.5, Light reflectance of >85% (WT),
thermal conductivity k = 0.052-0.057 W/m0K, Humidity Resistance of 95% ,
having Fire Performance CLASS O / CLASS 1 (BS 476), surface having 4
coats of white paint and micro-perforations and finished with a coat of
protective paint over the formed grid complete
SPECIFICATION FOR ARMSTRONG CEILINGS – PRIMA ADRIA
MICROLOOK EDGE WITH SILHOUETTE GRID(BLACK REVEAL)
Providing and fixing false ceiling system manufactured by M/s. Armstrong
World Industries using hot dipped galvanized steel section, rotary stitched
main tee of size 15mm x 42 mm web height, having 0.36 mm gauge at every
600 mm centre to centre maximum and rotary stitched cross tee of size 15
mm x 42 mm, having 0.33 mm gauge at every 600 mm. c/c. and wall angle of
size 19 x 19 mm., having 0.35 mm gauge fixed to the periphery of the wall.
The above grid is suspended at every 600mm c/c. in both directions using 2.0
mm. thick pre-straightened GI wire laying PRIMA ADRIA MICROLOOK
Edge ceiling tiles manufactured by M/s. Armstrong World Industries, of size
600mmx600mmx15mm having NRC 0.5, Light reflectance of >85% (WT),
thermal conductivity k = 0.052-0.057 W/m0K, Humidity Resistance of 95% ,
having Fire Performance CLASS O / CLASS 1 (BS 476), surface having 4
coats of white paint and micro-perforations and finished with a coat of
protective paint over the formed grid complete
SPECIFICATION FOR ARMSTRONG CEILINGS – PRIMA ADRIA
MICROLOOK EDGE WITH SILHOUETTE GRID(WHITE REVEAL)
Providing and fixing false ceiling system manufactured by M/s. Armstrong
World Industries using hot dipped galvanized steel section, rotary stitched
main tee of size 15mm x 42 mm web height, having 0.36 mm gauge at every
600 mm centre to centre maximum and rotary stitched cross tee of size 15
mm x 42 mm, having 0.33 mm gauge at every 600 mm. c/c. and wall angle of
size 19 x 19 mm., having 0.35 mm gauge fixed to the periphery of the wall.
The above grid is suspended at every 600mm c/c. in both directions using 2.0
mm. thick pre-straightened GI wire laying PRIMA ADRIA MICROLOOK
Edge ceiling tiles manufactured by M/s. Armstrong World Industries, of size
600mmx600mmx15mm having NRC 0.5, Light reflectance of >85% (WT),
thermal conductivity k = 0.052-0.057 W/m0K, Humidity Resistance of 95% ,
having Fire Performance CLASS O / CLASS 1 (BS 476), surface having 4
coats of white paint and micro-perforations and finished with a coat of
protective paint over the formed grid complete
SPECIFICATION FOR ARMSTRONG CEILINGS – PRIMA ADRIA
TEGULAR EDGE WITH XL 24MM GRID
Providing and fixing in true horizontal level 600 mm X 600 mm false ceiling
system manufactured by M/s. Armstrong World Industries using hot dipped
galvanized steel section, rotary stitched main tee of size 24 mm x 30 mm
web height, having 0.27 mm gauge at every 600 mm centre to centre
maximum and rotary stitched cross tee of size 24 mm x 30 mm, having 0.27
mm gauge at every 600 mm. c/c. and wall angle of size 19 x 19 mm., having
0.35 mm gauge fixed to the periphery of the wall. The above grid is
suspended at every 600mm c/c. in both directions using 2.0 mm. thick pre-
straightened GI wire laying PRIMA ADRIA TEGULAR Edge ceiling tiles
manufactured by M/s. Armstrong World Industries, of size
600mmx600mmx15mm having NRC 0.5, Light reflectance of >85% (WT),
thermal conductivity k = 0.052-0.057 W/m0K, Humidity Resistance of 95% ,
having Fire Performance CLASS O / CLASS 1 (BS 476), surface having 4
coats of white paint and micro-perforations and finished with a coat of
protective paint over the formed grid complete.
SPECIFICATION FOR ARMSTRONG CEILINGS – PRIMA ADRIA
MICROLOOK EDGE WITH XL 15MM GRID
Providing and fixing in true horizontal level 600 mm X 600 mm false ceiling
system manufactured by M/s. Armstrong World Industries using hot dipped
galvanized steel section, rotary stitched main tee of size 15 mm x 30 mm
web height, having 0.27 mm gauge at every 600 mm centre to centre
maximum and rotary stitched cross tee of size 15 mm x 30 mm, having 0.27
mm gauge at every 600 mm. c/c. and wall angle of size 19 x 19 mm., having
0.35 mm gauge fixed to the periphery of the wall. The above grid is
suspended at every 600mm c/c. in both directions using 2.0 mm. thick pre-
straightened GI wire laying PRIMA ADRIA MICROLOOK Edge ceiling tiles
manufactured by M/s. Armstrong World Industries, of size
600mmx600mmx15mm having NRC 0.5, Light reflectance of >85% (WT),
thermal conductivity k = 0.052-0.057 W/m0K, Humidity Resistance of 95% ,
having Fire Performance CLASS O / CLASS 1 (BS 476), surface having 4
coats of white paint and micro-perforations and finished with a coat of
protective paint over the formed grid complete
SPECIFICATION FOR ARMSTRONG CEILINGS – DUNE MAX BUTT
EDGE WITH XL 24MM GRID
Providing and fixing in true horizontal level 600 mm. X 600 mm. false ceiling
system manufactured by M/s. Armstrong World Industries using hot dipped
galvanized steel section, exposed surface with pre-coated capping, main tee
of size 24 x 32 mm., having 0.27 mm gauge at every 1200 mm. centre to
centre maximum and rotary stitched cross tee of size 24 x 27 mm, having
0.27 mm gauge at every 600 mm. c/c. and sub cross tee of size 24 x 27 mm,
having 0.25 mm gauge at 1200 mm c/c. and wall angle of size 19 x 19 mm.,
having 0.35 mm gauge fixed to the periphery of the wall. The above grid is
suspended at every 1200mm c/c. in both directions using 2.0 mm. thick pre-
straightened GI wire laying DUNE MAX BUTT Edge ceiling tiles
manufactured by M/s. Armstrong World Industries, of size
600mmx600mmx19mm having NRC 0.70, Light reflectance of >83% (WT),
thermal conductivity k = 0.052-0.057 W/m0K, Humidity Resistance of 95% ,
having Fire Performance CLASS O / CLASS 1 (BS 476), surface is crisp and
finely granulated surface with high light reflectance and scratch resistance
and back of the tile duly sanded and finished with a coat of protective paint
over the formed grid complete.
SPECIFICATION FOR ARMSTRONG CEILINGS – DUNE MAX TEGULAR
EDGE WITH XL 24MM GRID
Providing and fixing in true horizontal level 600 mm. X 600 mm. false ceiling
system manufactured by M/s. Armstrong World Industries using hot dipped
galvanized steel section, exposed surface with pre-coated capping, main tee
of size 24 x 32 mm., having 0.27 mm gauge at every 1200 mm. centre to
centre maximum and rotary stitched cross tee of size 24 x 27 mm, having
0.27 mm gauge at every 600 mm. c/c. and sub cross tee of size 24 x 27 mm,
having 0.25 mm gauge at 1200 mm c/c. and wall angle of size 19 x 19 mm.,
having 0.35 mm gauge fixed to the periphery of the wall. The above grid is
suspended at every 1200mm c/c. in both directions using 2.0 mm. thick pre-
straightened GI wire laying DUNE MAX TEGULAR Edge ceiling tiles
manufactured by M/s. Armstrong World Industries, of size
600mmx600mmx19mm having NRC 0.70, Light reflectance of >83% (WT),
thermal conductivity k = 0.052-0.057 W/m0K, Humidity Resistance of 95% ,
having Fire Performance CLASS O / CLASS 1 (BS 476), surface is crisp and
finely granulated surface with high light reflectance and scratch resistance
and back of the tile duly sanded and finished with a coat of protective paint
over the formed grid complete.
SPECIFICATION FOR ARMSTRONG CEILINGS – DUNE MAX
MICROLOOK EDGE WITH XL 15MM GRID
Providing and fixing in true horizontal level 600 mm. X 600 mm. false ceiling
system manufactured by M/s. Armstrong World Industries using hot dipped
galvanized steel section, exposed surface with pre-coated capping, main tee
of size 15 x 32 mm., having 0.27 mm gauge at every 1200 mm. centre to
centre maximum and rotary stitched cross tee of size 15 x 32 mm, having
0.27 mm gauge at every 600 mm. c/c. and sub cross tee of size 15 x 32 mm,
having 0.25 mm gauge at 1200 mm c/c. and wall angle of size 19 x 19 mm.,
having 0.35 mm gauge fixed to the periphery of the wall. The above grid is
suspended at every 1200mm c/c. in both directions using 2.0 mm. thick pre-
straightened GI wire laying DUNE MAX MICROLOOK Edge ceiling tiles
manufactured by M/s. Armstrong World Industries, of size
600mmx600mmx19mm having NRC 0.70, Light reflectance of >83% (WT),
thermal conductivity k = 0.052-0.057 W/m0K, Humidity Resistance of 95% ,
having Fire Performance CLASS O / CLASS 1 (BS 476), surface is crisp and
finely granulated surface with high light reflectance and scratch resistance
and back of the tile duly sanded and finished with a coat of protective paint
over the formed grid complete.
SPECIFICATION FOR ARMSTRONG CEILINGS – DUNE MAX
MICROLOOK EDGE WITH SELECT 15MM GRID.
Providing and fixing in true horizontal level 600 mm X 600 mm false ceiling
system manufactured by M/s. Armstrong World Industries using hot dipped
galvanized steel section, rotary stitched main tee of size 15 mm x 30 mm
web height, having 0.27 mm gauge at every 600 mm centre to centre
maximum and rotary stitched cross tee of size 15 mm x 30 mm, having 0.27
mm gauge at every 600 mm. c/c. and wall angle of size 19 x 19 mm., having
0.35 mm gauge fixed to the periphery of the wall. The above grid is
suspended at every 600mm c/c. in both directions using 2.0 mm. thick pre-
straightened GI wire laying DUNE MAX MICROLOOK Edge ceiling tiles
manufactured by M/s. Armstrong World Industries, of size
600mmx600mmx19mm having NRC 0.70, Light reflectance of >83% (WT),
thermal conductivity k = 0.052-0.057 W/m0K, Humidity Resistance of 95% ,
having Fire Performance CLASS O / CLASS 1 (BS 476), surface is crisp and
finely granulated surface with high light reflectance and scratch resistance
and back of the tile duly sanded and finished with a coat of protective paint
over the formed grid complete.
SPECIFICATION FOR ARMSTRONG CEILINGS – DUNE MAX
MICROLOOK EDGE WITH SILHOUETTE GRID(BLACK REVEAL)
Providing and fixing false ceiling system manufactured by M/s. Armstrong
World Industries using hot dipped galvanized steel section, rotary stitched
main tee of size 15mm x 42 mm web height, having 0.36 mm gauge at every
600 mm centre to centre maximum and rotary stitched cross tee of size 15
mm x 42 mm, having 0.33 mm gauge at every 600 mm. c/c. and wall angle of
size 19 x 19 mm., having 0.35 mm gauge fixed to the periphery of the wall.
The above grid is suspended at every 600mm c/c. in both directions using 2.0
mm. thick pre-straightened GI wire laying DUNE MAX MICROLOOK Edge
ceiling tiles manufactured by M/s. Armstrong World Industries, of size
600mmx600mmx19mm having NRC 0.70, Light reflectance of >83% (WT),
thermal conductivity k = 0.052-0.057 W/m0K, Humidity Resistance of 95% ,
having Fire Performance CLASS O / CLASS 1 (BS 476), surface is crisp and
finely granulated surface with high light reflectance and scratch resistance
and back of the tile duly sanded and finished with a coat of protective paint
over the formed grid complete.
SPECIFICATION FOR ARMSTRONG CEILINGS – DUNE MAX
MICROLOOK EDGE WITH SILHOUETTE GRID (WHITE REVEAL)
Providing and fixing false ceiling system manufactured by M/s. Armstrong
World Industries using hot dipped galvanized steel section, rotary stitched
main tee of size 15mm x 42 mm web height, having 0.36 mm gauge at every
600 mm centre to centre maximum and rotary stitched cross tee of size 15
mm x 42 mm, having 0.33 mm gauge at every 600 mm. c/c. and wall angle of
size 19 x 19 mm., having 0.35 mm gauge fixed to the periphery of the wall.
The above grid is suspended at every 600mm c/c. in both directions using 2.0
mm. thick pre-straightened GI wire laying DUNE MAX MICROLOOK Edge
ceiling tiles manufactured by M/s. Armstrong World Industries, of size
600mmx600mmx19mm having NRC 0.70, Light reflectance of >83% (WT),
thermal conductivity k = 0.052-0.057 W/m0K, Humidity Resistance of 95% ,
having Fire Performance CLASS O / CLASS 1 (BS 476), surface is crisp and
finely granulated surface with high light reflectance and scratch resistance
and back of the tile duly sanded and finished with a coat of protective paint
over the formed grid complete.
SPECIFICATION FOR ARMSTRONG CEILINGS – DUNE MAX TEGULAR
EDGE WITH XL 24MM SELECT GRID
Providing and fixing in true horizontal level 600 mm X 600 mm false ceiling
system manufactured by M/s. Armstrong World Industries using hot dipped
galvanized steel section, rotary stitched main tee of size 24 mm x 30 mm
web height, having 0.27 mm gauge at every 600 mm centre to centre
maximum and rotary stitched cross tee of size 24 mm x 30 mm, having 0.27
mm gauge at every 600 mm. c/c. and wall angle of size 19 x 19 mm., having
0.35 mm gauge fixed to the periphery of the wall. The above grid is
suspended at every 600mm c/c. in both directions using 2.0 mm. thick pre-
straightened GI wire laying DUNE MAX TEGULAR Edge ceiling tiles
manufactured by M/s. Armstrong World Industries, of size
600mmx600mmx19mm having NRC 0.70, Light reflectance of >83% (WT),
thermal conductivity k = 0.052-0.057 W/m0K, Humidity Resistance of 95% ,
having Fire Performance CLASS O / CLASS 1 (BS 476), surface is crisp and
finely granulated surface with high light reflectance and scratch resistance
and back of the tile duly sanded and finished with a coat of protective paint
over the formed grid complete.
SPECIFICATION FOR ARMSTRONG CEILINGS – DUNE MAX
MICROLOOK EDGE WITH XL 15MM GRID.
Providing and fixing in true horizontal level 600 mm X 600 mm false ceiling
system manufactured by M/s. Armstrong World Industries using hot dipped
galvanized steel section, rotary stitched main tee of size 15 mm x 30 mm
web height, having 0.27 mm gauge at every 600 mm centre to centre
maximum and rotary stitched cross tee of size 15 mm x 30 mm, having 0.27
mm gauge at every 600 mm. c/c. and wall angle of size 19 x 19 mm., having
0.35 mm gauge fixed to the periphery of the wall. The above grid is
suspended at every 600mm c/c. in both directions using 2.0 mm. thick pre-
straightened GI wire laying DUNE MAX MICROLOOK Edge ceiling tiles
manufactured by M/s. Armstrong World Industries, of size
600mmx600mmx19mm having NRC 0.70, Light reflectance of >83% (WT),
thermal conductivity k = 0.052-0.057 W/m0K, Humidity Resistance of 95% ,
having Fire Performance CLASS O / CLASS 1 (BS 476), surface is crisp and
finely granulated surface with high light reflectance and scratch resistance
and back of the tile duly sanded and finished with a coat of protective paint
over the formed grid complete.
SPECIFICATION FOR ARMSTRONG CEILINGS – ULTIMA BUTT EDGE
WITH XL 24MM GRID
Providing and fixing in true horizontal level 600 mm. X 600 mm. false ceiling
system manufactured by M/s. Armstrong World Industries using hot dipped
galvanized steel section, exposed surface with pre-coated capping, main tee
of size 24 x 32 mm., having 0.27 mm gauge at every 1200 mm. centre to
centre maximum and rotary stitched cross tee of size 24 x 27 mm, having
0.27 mm gauge at every 600 mm. c/c. and sub cross tee of size 24 x 27 mm,
having 0.25 mm gauge at 1200 mm c/c. and wall angle of size 19 x 19 mm.,
having 0.35 mm gauge fixed to the periphery of the wall. The above grid is
suspended at every 1200mm c/c. in both directions using 2.0 mm. thick pre-
straightened GI wire laying ULTIMA BUTT Edge ceiling tiles manufactured
by M/s. Armstrong World Industries, of size 600mmx600mmx19mm having
NRC 0.7, Light reflectance of >90% (WT), thermal conductivity k = 0.052-
0.057 W/m0K, Humidity Resistance of 95% , having Fire Performance CLASS
O / CLASS 1 (BS 476), surface having white unperforated smooth surface
with high light reflectance and scratch resistance and finished with a coat
of protective paint over the formed grid complete
SPECIFICATION FOR ARMSTRONG CEILINGS – ULTIMA TEGULAR
EDGE WITH XL 24MM GRID
Providing and fixing in true horizontal level 600 mm. X 600 mm. false ceiling
system manufactured by M/s. Armstrong World Industries using hot dipped
galvanized steel section, exposed surface with pre-coated capping, main tee
of size 24 x 32 mm., having 0.27 mm gauge at every 1200 mm. centre to
centre maximum and rotary stitched cross tee of size 24 x 27 mm, having
0.27 mm gauge at every 600 mm. c/c. and sub cross tee of size 24 x 27 mm,
having 0.25 mm gauge at 1200 mm c/c. and wall angle of size 19 x 19 mm.,
having 0.35 mm gauge fixed to the periphery of the wall. The above grid is
suspended at every 1200mm c/c. in both directions using 2.0 mm. thick pre-
straightened GI wire laying ULTIMA TEGULAR Edge ceiling tiles
manufactured by M/s. Armstrong World Industries, of size
600mmx600mmx19mm having NRC 0.7, Light reflectance of >90% (WT),
thermal conductivity k = 0.052-0.057 W/m0K, Humidity Resistance of 95% ,
having Fire Performance CLASS O / CLASS 1 (BS 476), surface having white
un-perforated smooth surface with high light reflectance and scratch
resistance and finished with a coat of protective paint over the formed grid
complete
SPECIFICATION FOR ARMSTRONG CEILINGS – ULTIMA MICROLOOK
EDGE WITH XL 15MM GRID
Providing and fixing in true horizontal level 600 mm. X 600 mm. false ceiling
system manufactured by M/s. Armstrong World Industries using hot dipped
galvanized steel section, exposed surface with pre-coated capping, main tee
of size 15 x 32 mm., having 0.27 mm gauge at every 1200 mm. centre to
centre maximum and rotary stitched cross tee of size 15 x 32 mm, having
0.27 mm gauge at every 600 mm. c/c. and sub cross tee of size 15 x 32 mm,
having 0.25 mm gauge at 1200 mm c/c. and wall angle of size 19 x 19 mm.,
having 0.35 mm gauge fixed to the periphery of the wall. The above grid is
suspended at every 1200mm c/c. in both directions using 2.0 mm. thick pre-
straightened GI wire laying ULTIMA MICROLOOK Edge ceiling tiles
manufactured by M/s. Armstrong World Industries, of size
600mmx600mmx19mm having NRC 0.7, Light reflectance of >90% (WT),
thermal conductivity k = 0.052-0.057 W/m0K, Humidity Resistance of 95% ,
having Fire Performance CLASS O / CLASS 1 (BS 476), surface having white
un-perforated smooth surface with high light reflectance and scratch
resistance and finished with a coat of protective paint over the formed grid
complete
SPECIFICATION FOR ARMSTRONG CEILINGS – ULTIMA MICROLOOK
EDGE WITH SILHOUETTE GRID(BLACK REVEAL)
Providing and fixing false ceiling system manufactured by M/s. Armstrong
World Industries using hot dipped galvanized steel section, rotary stitched
main tee of size 15mm x 42 mm web height, having 0.36 mm gauge at every
600 mm centre to centre maximum and rotary stitched cross tee of size 15
mm x 42 mm, having 0.33 mm gauge at every 600 mm. c/c. and wall angle of
size 19 x 19 mm., having 0.35 mm gauge fixed to the periphery of the wall.
The above grid is suspended at every 600mm c/c. in both directions using 2.0
mm. thick pre-straightened GI wire laying ULTIMA MICROLOOK WITH
SILHOUETTE GRID(BLACK REVEAL) ceiling tiles manufactured by M/s.
Armstrong World Industries, of size 600mmx600mmx19mm having NRC 0.7,
Light reflectance of >90% (WT), thermal conductivity k = 0.052-0.057
W/m0K, Humidity Resistance of 95% , having Fire Performance CLASS O /
CLASS 1 (BS 476), surface having white un-perforated smooth surface with
high light reflectance and scratch resistance and finished with a coat of
protective paint over the formed grid complete
SPECIFICATION FOR ARMSTRONG CEILINGS – ULTIMA MICROLOOK
EDGE WITH SILHOUETTE GRID(WHITE REVEAL)
Providing and fixing false ceiling system manufactured by M/s. Armstrong
World Industries using hot dipped galvanized steel section, rotary stitched
main tee of size 15mm x 42 mm web height, having 0.36 mm gauge at every
600 mm centre to centre maximum and rotary stitched cross tee of size 15
mm x 42 mm, having 0.33 mm gauge at every 600 mm. c/c. and wall angle of
size 19 x 19 mm., having 0.35 mm gauge fixed to the periphery of the wall.
The above grid is suspended at every 600mm c/c. in both directions using 2.0
mm. thick pre-straightened GI wire laying ULTIMA MICROLOOK WITH
SILHOUETTE GRID(WHITE REVEAL) ceiling tiles manufactured by M/s.
Armstrong World Industries, of size 600mmx600mmx19mm having NRC 0.7,
Light reflectance of >90% (WT), thermal conductivity k = 0.052-0.057
W/m0K, Humidity Resistance of 95% , having Fire Performance CLASS O /
CLASS 1 (BS 476), surface having white un-perforated smooth surface with
high light reflectance and scratch resistance and finished with a coat of
protective paint over the formed grid complete
SPECIFICATION FOR ARMSTRONG CEILINGS – ULTIMA TEGULAR
EDGE WITH XL 24MM GRID.
Providing and fixing in true horizontal level 600 mm X 600 mm false ceiling
system manufactured by M/s. Armstrong World Industries using hot dipped
galvanized steel section, rotary stitched main tee of size 24 mm x 30 mm
web height, having 0.27 mm gauge at every 600 mm centre to centre
maximum and rotary stitched cross tee of size 24 mm x 30 mm, having 0.27
mm gauge at every 600 mm. c/c. and wall angle of size 19 x 19 mm., having
0.35 mm gauge fixed to the periphery of the wall. The above grid is
suspended at every 600mm c/c. in both directions using 2.0 mm. thick pre-
straightened GI wire laying ULTIMA TEGULAR EDGE WITH XL 24MM
SELECT GRID ceiling tiles manufactured by M/s. Armstrong World
Industries, of size 600mmx600mmx19mm having NRC 0.7, Light reflectance
of >90% (WT), thermal conductivity k = 0.052-0.057 W/m0K, Humidity
Resistance of 95% , having Fire Performance CLASS O / CLASS 1 (BS 476),
surface having white un-perforated smooth surface with high light
reflectance and scratch resistance and finished with a coat of protective
paint over the formed grid complete
SPECIFICATION FOR ARMSTRONG CEILINGS – ULTIMA MICROLOOK
EDGE WITH XL 15MM GRID.
Providing and fixing in true horizontal level 600 mm X 600 mm false ceiling
system manufactured by M/s. Armstrong World Industries using hot dipped
galvanized steel section, rotary stitched main tee of size 15 mm x 30 mm
web height, having 0.27 mm gauge at every 600 mm centre to centre
maximum and rotary stitched cross tee of size 15 mm x 30 mm, having 0.27
mm gauge at every 600 mm. c/c. and wall angle of size 19 x 19 mm., having
0.35 mm gauge fixed to the periphery of the wall. The above grid is
suspended at every 600mm c/c. in both directions using 2.0 mm. thick pre-
straightened GI wire laying ULTIMA MICROLOOK WITH XL 15MM
SELECT GRID ceiling tiles manufactured by M/s. Armstrong World
Industries, of size 600mmx600mmx19mm having NRC 0.7, Light reflectance
of >90% (WT), thermal conductivity k = 0.052-0.057 W/m0K, Humidity
Resistance of 95% , having Fire Performance CLASS O / CLASS 1 (BS 476),
surface having white un-perforated smooth surface with high light
reflectance and scratch resistance and finished with a coat of protective
paint over the formed grid complete
SPECIFICATION FOR ARMSTRONG CEILINGS – NEWTONE BUTT
EDGE WITH XL 24MM GRID
Providing and fixing in true horizontal level 600 mm. X 600 mm. false ceiling
system manufactured by M/s. Armstrong World Industries using hot dipped
galvanized steel section, exposed surface with pre-coated capping, main tee
of size 24 x 32 mm. at every 1200 mm. c/c. maximum and rotary stitched
cross tee of size 24 x 27 mm at every 600 mm. c/c. and sub cross tee of size
24 x 25 mm at 1200 mm c/c. and wall angle of size 19 x 19 mm. fixed to the
periphery of the wall. The above grid is suspended at every 1200mm c/c. in
both directions using 2.0 mm. thick pre-straightened GI wire laying
NEWTONE BUTT EDGE (Hydrated Calcium Silicate Tile) ceiling tiles
manufactured by M/s. Armstrong World Industries, having RH 100% and size
600mmx600mmx6mm over the formed grid complete.
SPECIFICATION FOR ARMSTRONG CEILINGS – NEWTONE BUTT
EDGE WITH XL 24MM GRID
Providing and fixing in true horizontal level 600 mm X 600 mm false ceiling
system manufactured by M/s. Armstrong World Industries using hot dipped
galvanized steel section, rotary stitched main tee of size 24 mm x 30 mm
web height, having 0.27 mm gauge at every 600 mm centre to centre
maximum and rotary stitched cross tee of size 24 mm x 30 mm, having 0.27
mm gauge at every 600 mm. c/c. and wall angle of size 19 x 19 mm., having
0.35 mm gauge fixed to the periphery of the wall. The above grid is
suspended at every 600mm c/c. in both directions using 2.0 mm. thick pre-
straightened GI wire laying NEWTONE BUTT EDGE (Hydrated Calcium
Silicate Tile) ceiling tiles manufactured by M/s. Armstrong World
Industries, having RH 100% and size 600mmx600mmx6mm over the formed
grid complete.
SPECIFICATION FOR ARMSTRONG CEILINGS – NEWTONE
MICROLOOK EDGE WITH XL 15MM GRID
Providing and fixing in true horizontal level 600 mm X 600 mm false ceiling
system manufactured by M/s. Armstrong World Industries using hot dipped
galvanized steel section, rotary stitched main tee of size 15 mm x 30 mm
web height, having 0.27 mm gauge at every 600 mm centre to centre
maximum and rotary stitched cross tee of size 15 mm x 30 mm, having 0.27
mm gauge at every 600 mm. c/c. and wall angle of size 19 x 19 mm., having
0.35 mm gauge fixed to the periphery of the wall. The above grid is
suspended at every 600mm c/c. in both directions using 2.0 mm. thick pre-
straightened GI wire laying NEWTONE MICROLOOK EDGE (Hydrated
Calcium Silicate Tile) ceiling tiles manufactured by M/s. Armstrong World
Industries, having RH 100% and size 600mmx600mmx6mm over the formed
grid complete.
SPECIFICATION FOR ARMSTRONG CEILINGS – NEWTONE BUTT EDGE
WITH SLOTTED GRID (SELECT)
Providing and fixing in true horizontal level 600 mm. X 600 mm. false ceiling
system manufactured by M/s. Armstrong World Industries using hot dipped
galvanized steel section, exposed surface with pre-coated capping, main tee
of size 24 x 32 mm. at every 1200 mm. c/c. maximum and rotary stitched
cross tee of size 24 x 27 mm at every 600 mm. c/c. and sub cross tee of size
24 x 25 mm at 1200 mm c/c. and wall angle of size 19 x 19 mm. fixed to the
periphery of the wall. The above grid is suspended at every 1200mm c/c. in
both directions using 2.0 mm. thick pre-straightened GI wire laying
NEWTONE BUTT EDGE (Hydrated Calcium Silicate Tile) ceiling tiles manufactured
by M/s. Armstrong World Industries, having RH 100% and size
600mmx600mmx6mm over the formed grid complete.
SPECIFICATION FOR ARMSTRONG CEILINGS – DUNE COLORTONE
TEGULAR EDGE WITH XL 24MM GRID
Providing and fixing in true horizontal level 600 mm. X 600 mm. false ceiling
system manufactured by M/s. Armstrong World Industries using hot dipped
galvanized steel section, exposed surface with pre-coated capping, main tee
of size 24 x 32 mm., having 0.27 mm gauge at every 1200 mm. centre to
centre maximum and rotary stitched cross tee of size 24 x 27 mm, having
0.27 mm gauge at every 600 mm. c/c. and sub cross tee of size 24 x 27 mm,
having 0.25 mm gauge at 1200 mm c/c. and wall angle of size 19 x 19 mm.,
having 0.35 mm gauge fixed to the periphery of the wall. The above grid is
suspended at every 1200mm c/c. in both directions using 2.0 mm. thick pre-
straightened GI wire laying laying Dune Colortone Tegular Edge ceiling tiles
manufactured by M/s. Armstrong World Industries, of size
600mmx600mmx15mm having NRC 0.55, thermal conductivity k = 0.052-
0.057 W/m0K, Humidity Resistance of 95% , having Fire Performance CLASS
O / CLASS 1 (BS 476),with ---------------colour
SPECIFICATION FOR ARMSTRONG CEILINGS – DUNE COLORTONE
BUTT EDGE WITH 24MM SELECT GRID.
Providing and fixing in true horizontal level 600 mm X 600 mm false ceiling
system manufactured by M/s. Armstrong World Industries using hot dipped
galvanized steel section, rotary stitched main tee of size 24 mm x 30 mm
web height, having 0.27 mm gauge at every 600 mm centre to centre
maximum and rotary stitched cross tee of size 24 mm x 30 mm, having 0.27
mm gauge at every 600 mm. c/c. and wall angle of size 19 x 19 mm., having
0.35 mm gauge fixed to the periphery of the wall. The above grid is
suspended at every 600mm c/c. in both directions using 2.0 mm. thick pre-
straightened GI wire laying Dune Colortone Butt Edge ceiling tiles
manufactured by M/s. Armstrong World Industries, of size
600mmx600mmx15mm having NRC 0.55, thermal conductivity k = 0.052-
0.057 W/m0K, Humidity Resistance of 95% , having Fire Performance CLASS
O / CLASS 1 (BS 476),with ---------------colour
SPECIFICATION FOR ARMSTRONG CEILINGS – DUNE COLORTONE
TEGULAR EDGE WITH XL 24MM GRID.
Providing and fixing in true horizontal level 600 mm X 600 mm false ceiling
system manufactured by M/s. Armstrong World Industries using hot dipped
galvanized steel section, rotary stitched main tee of size 24 mm x 30 mm
web height, having 0.27 mm gauge at every 600 mm centre to centre
maximum and rotary stitched cross tee of size 24 mm x 30 mm, having 0.27
mm gauge at every 600 mm. c/c. and wall angle of size 19 x 19 mm., having
0.35 mm gauge fixed to the periphery of the wall. The above grid is
suspended at every 600mm c/c. in both directions using 2.0 mm. thick pre-
straightened GI wire laying Dune Colortone Tegular select Edge ceiling tiles
manufactured by M/s. Armstrong World Industries, of size
600mmx600mmx15mm having NRC 0.55, thermal conductivity k = 0.052-
0.057 W/m0K, Humidity Resistance of 95% , having Fire Performance CLASS
O / CLASS 1 (BS 476),with ---------------colour
SPECIFICATION FOR ARMSTRONG CEILINGS – CONTRAST SQUARE /
CIRCLES / LINEAR MICROLOOK EDGE WITH XL 15MM GRID
Providing and fixing in true horizontal level 600 mm. X 600 mm. false ceiling
system manufactured by M/s. Armstrong World Industries using hot dipped
galvanized steel section, exposed surface with pre-coated capping, main tee
of size 15 x 32 mm., having 0.27 mm gauge at every 1200 mm. centre to
centre maximum and rotary stitched cross tee of size 15 x 32 mm, having
0.27 mm gauge at every 600 mm. c/c. and sub cross tee of size 15 x 32 mm,
having 0.25 mm gauge at 1200 mm c/c. and wall angle of size 19 x 19 mm.,
having 0.35 mm gauge fixed to the periphery of the wall. The above grid is
suspended at every 1200mm c/c. in both directions using 2.0 mm. thick pre-
straightened GI wire laying Constrast Square / Circles / Linear Microlook
with xl 15mm select grid ceiling tiles manufactured by M/s. Armstrong
World Industries, of size 600mmx600mmx15mm having NRC 0.55, Light
reflectance of >83% (WT), thermal conductivity k = 0.052-0.057 W/m0K,
Humidity Resistance of 95% , having Fire Performance CLASS O / CLASS 1
(BS 476), surface is crisp finely granulated with micro-perforations / 3
coats of white paint with emboss surface and finished with a coat of
protective paint over the formed grid complete
SPECIFICATION FOR ARMSTRONG CEILINGS – CONTRAST SQUARE /
CIRCLES / LINEAR MICROLOOK EDGE WITH SILHOUETTE GRID
(BLACK REVEAL)
Providing and fixing false ceiling system manufactured by M/s. Armstrong
World Industries using hot dipped galvanized steel section, rotary stitched
main tee of size 15mm x 42 mm web height, having 0.36 mm gauge at every
600 mm centre to centre maximum and rotary stitched cross tee of size 15
mm x 42 mm, having 0.33 mm gauge at every 600 mm. c/c. and wall angle of
size 19 x 19 mm., having 0.35 mm gauge fixed to the periphery of the wall.
The above grid is suspended at every 600mm c/c. in both directions using 2.0
mm. thick pre-straightened GI wire laying Constrast Square / Circles /
Linear Microlook with xl 15mm select grid ceiling tiles manufactured by M/s.
Armstrong World Industries, of size 600mmx600mmx15mm having NRC
0.55, Light reflectance of >83% (WT), thermal conductivity k = 0.052-0.057
W/m0K, Humidity Resistance of 95% , having Fire Performance CLASS O /
CLASS 1 (BS 476), surface is crisp finely granulated with micro-perforations
/ 3 coats of white paint with emboss surface and finished with a coat of
protective paint over the formed grid complete
SPECIFICATION FOR ARMSTRONG CEILINGS – CONTRAST SQUARE /
CIRCLES / LINEAR MICROLOOK EDGE WITH SILHOUETTE GRID
(WHITE REVEAL)
Providing and fixing false ceiling system manufactured by M/s. Armstrong
World Industries using hot dipped galvanized steel section, rotary stitched
main tee of size 15mm x 42 mm web height, having 0.36 mm gauge at every
600 mm centre to centre maximum and rotary stitched cross tee of size 15
mm x 42 mm, having 0.33 mm gauge at every 600 mm. c/c. and wall angle of
size 19 x 19 mm., having 0.35 mm gauge fixed to the periphery of the wall.
The above grid is suspended at every 600mm c/c. in both directions using 2.0
mm. thick pre-straightened GI wire laying Constrast Square / Circles /
Linear Microlook with xl 15mm select grid ceiling tiles manufactured by M/s.
Armstrong World Industries, of size 600mmx600mmx15mm having NRC
0.55, Light reflectance of >83% (WT), thermal conductivity k = 0.052-0.057
W/m0K, Humidity Resistance of 95% , having Fire Performance CLASS O /
CLASS 1 (BS 476), surface is crisp finely granulated with micro-perforations
/ 3 coats of white paint with emboss surface and finished with a coat of
protective paint over the formed grid complete
SPECIFICATION FOR ARMSTRONG CEILINGS – CONSTRAST SQUARE
/ CIRCLES / LINEAR MICROLOOK EDGE WITH XL 15MM GRID.
Providing and fixing in true horizontal level 600 mm X 600 mm false ceiling
system manufactured by M/s. Armstrong World Industries using hot dipped
galvanized steel section, rotary stitched main tee of size 15 mm x 30 mm
web height, having 0.27 mm gauge at every 600 mm centre to centre
maximum and rotary stitched cross tee of size 15 mm x 30 mm, having 0.27
mm gauge at every 600 mm. c/c. and wall angle of size 19 x 19 mm., having
0.35 mm gauge fixed to the periphery of the wall. The above grid is
suspended at every 600mm c/c. in both directions using 2.0 mm. thick pre-
straightened GI wire laying Constrast Square / Circles / Linear Microlook
with xl 15mm select grid ceiling tiles manufactured by M/s. Armstrong
World Industries, of size 600mmx600mmx15mm having NRC 0.55, Light
reflectance of >83% (WT), thermal conductivity k = 0.052-0.057 W/m0K,
Humidity Resistance of 95% , having Fire Performance CLASS O / CLASS 1
(BS 476), surface is crisp finely granulated with micro-perforations / 3
coats of white paint with emboss surface and finished with a coat of
protective paint over the formed grid complete
SPECIFICATION FOR ARMSTRONG CEILINGS – BIOGUARD
PERFORATED BUTT EDGE WITH XL 24MM GRID
Providing and fixing in true horizontal level 600 mm. X 600 mm. false ceiling
system manufactured by M/s. Armstrong World Industries using hot dipped
galvanized steel section, exposed surface with pre-coated capping, main tee
of size 24 x 32 mm. at every 1200 mm. c/c. maximum and rotary stitched
cross tee of size 24 x 27 mm at every 600 mm. c/c. and sub cross tee of size
24 x 25 mm at 1200 mm c/c. and wall angle of size 19 x 19 mm. fixed to the
periphery of the wall. The above grid is suspended at every 1200mm c/c. in
both directions using 2.0 mm. thick pre-straightened GI wire laying
BIOGUARD PERFORATED BUTT EDGE ceiling tiles manufactured by M/s.
Armstrong World Industries, having NRC 0.60, Light reflectance of >83%
(WT), k = 0.052-0.057 W/m0K, having Fire Performance CLASS O / CLASS 1
(BS 476), Humidity Resistance of 95%, surface having 1 coat of white paint
surface with High Light Reflectance & Scratch Reflectance, back of the tile
duly sanded and finished with a coat of paint of size 600mmx600mmx15mm
over the formed grid complete.
SPECIFICATION FOR ARMSTRONG CEILINGS – BIOGUARD BUTT
EDGE WITH RETAIL 24MM GRID
Providing and fixing in true horizontal level 600 mm. X 600 mm. false ceiling
system manufactured by M/s. Armstrong World Industries using hot dipped
galvanized steel section, exposed surface with pre-coated capping, main tee
of size 24 x 32 mm. at every 1200 mm. c/c. maximum and rotary stitched
cross tee of size 24 x 27 mm at every 600 mm. c/c. and sub cross tee of size
24 x 25 mm at 1200 mm c/c. and wall angle of size 19 x 19 mm. fixed to the
periphery of the wall. The above grid is suspended at every 1200mm c/c. in
both directions using 2.0 mm. thick pre-straightened GI wire laying
BIOGUARD BUTT EDGE ceiling tiles manufactured by M/s. Armstrong
World Industries, having NRC 0.10, having Light reflectance of >90% (WT), k
= 0.052-0.057 W/m0K, having Fire Performance CLASS O / CLASS 1 (BS
476), Humidity Resistance of 95%, surface having 1 coat of white paint
surface with High Light Reflectance & Scratch Reflectance, back of the tile
duly sanded and finished with a coat of paint of size 600mmx600mmx15mm
over the formed grid complete.
SPECIFICATION FOR ARMSTRONG CEILINGS – NEEVA BUTT EDGE
WITH XL 24MM GRID
Providing and fixing in true horizontal level 600 mm. X 600 mm. false ceiling
system manufactured by M/s. Armstrong World Industries using hot dipped
galvanized steel section, exposed surface with pre-coated capping, main tee
of size 24 x 32 mm. at every 1200 mm. c/c. maximum and rotary stitched
cross tee of size 24 x 27 mm at every 600 mm. c/c. and sub cross tee of size
24 x 25 mm at 1200 mm c/c. and wall angle of size 19 x 19 mm. fixed to the
periphery of the wall. The above grid is suspended at every 1200mm c/c. in
both directions using 2.0 mm. thick pre-straightened GI wire laying NEEVA
BUTT EDGE ceiling tiles manufactured by M/s. Armstrong World
Industries, having NRC 0.90, having Light reflectance of >83% (WT), k =
0.036 W/m0K, having Fire Performance CLASS O / CLASS 1 (BS 476),
Humidity Resistance of 95%, surface having 1 coat of white paint surface
with High Light Reflectance & Scratch Reflectance, back of the tile duly
sanded and finished with a coat of paint of size 600mmx600mmx18mm over
the formed grid complete.
SPECIFICATION FOR ARMSTRONG CEILINGS – VisualV49
MICROLOOK EDGE WITH SILHOUETTE GRID
Providing and fixing false ceiling system manufactured by M/s. Armstrong
World Industries using hot dipped galvanized steel section, rotary stitched
main tee of size 15mm x 42 mm web height, having 0.36 mm gauge at every
600 mm centre to centre maximum and rotary stitched cross tee of size 15
mm x 42 mm, having 0.33 mm gauge at every 600 mm. c/c. and wall angle of
size 19 x 19 mm., having 0.35 mm gauge fixed to the periphery of the wall.
The above grid is suspended at every 600mm c/c. in both directions using 2.0
mm. thick pre-straightened GI wire laying VisualV49microlook with
silhouette grid ceiling tiles manufactured by M/s. Armstrong World
Industries, of size 600mmx600mmx15mm having NRC 0.95, thermal
conductivity k = 0.052-0.057 W/m0K, Humidity Resistance of 70% , having
Fire Performance CLASS O / CLASS 1 (BS 476) over the formed grid
complete.
SPECIFICATION FOR ARMSTRONG CEILINGS – VisualV49
MICROLOOK EDGE WITH XL 15 mm GRID
Providing and fixing false ceiling system manufactured by M/s. Armstrong
World Industries using hot dipped galvanized steel section, rotary stitched
main tee of size 15mm x 42 mm web height, having 0.36 mm gauge at every
600 mm centre to centre maximum and rotary stitched cross tee of size 15
mm x 42 mm, having 0.33 mm gauge at every 600 mm. c/c. and wall angle of
size 19 x 19 mm., having 0.35 mm gauge fixed to the periphery of the wall.
The above grid is suspended at every 600mm c/c. in both directions using 2.0
mm. thick pre-straightened GI wire laying VisualV49 microlook with XL 15
mm grid ceiling tiles manufactured by M/s. Armstrong World Industries, of
size 600mmx600mmx15mm having NRC 0.95, thermal conductivity k =
0.052-0.057 W/m0K, Humidity Resistance of 70% , having Fire Performance
CLASS O / CLASS 1 (BS 476) over the formed grid complete.
SPECIFICATION FOR ARMSTRONG CEILINGS – OPTIMA TEGULAR
EDGE WITH XL 24MM GRID
Providing and fixing in true horizontal level 600 mm. X 600 mm. false ceiling
system manufactured by M/s. Armstrong World Industries using hot dipped
galvanized steel section, exposed surface with pre-coated capping, main tee
of size 24 x 32 mm., having 0.27 mm gauge at every 1200 mm. centre to
centre maximum and rotary stitched cross tee of size 24 x 27 mm, having
0.27 mm gauge at every 600 mm. c/c. and sub cross tee of size 24 x 27 mm,
having 0.25 mm gauge at 1200 mm c/c. and wall angle of size 19 x 19 mm.,
having 0.35 mm gauge fixed to the periphery of the wall. The above grid is
suspended at every 1200mm c/c. in both directions using 2.0 mm. thick pre-
straightened GI wire laying OPTIMA TEGULAR Edge ceiling tiles
manufactured by M/s. Armstrong World Industries, of size
600mmx600mmx25mm having NRC 1.0, Light reflectance of >89% (WT),
thermal conductivity k = 0.052-0.057 W/m0K, Humidity Resistance of 95% ,
having Fire Performance CLASS O / CLASS 1 (BS 476), surface having white
un-perforated smooth surface with high light reflectance and scratch
resistance and finished with a coat of protective paint over the formed grid
complete.
SPECIFICATION FOR ARMSTRONG CEILINGS – ELITE RH 90 BUTT
EDGE WITH SELECT 15 MM GRID.
Providing and fixing in true horizontal level 600 mm X 600 mm false ceiling
system manufactured by M/s. Armstrong World Industries using hot dipped
galvanized steel section, rotary stitched main tee of size 15 mm x 30 mm
web height, having 0.27 mm gauge at every 600 mm centre to centre
maximum and rotary stitched cross tee of size 15 mm x 30 mm, having 0.27
mm gauge at every 600 mm. c/c. and wall angle of size 19 x 19 mm., having
0.35 mm gauge fixed to the periphery of the wall. The above grid is
suspended at every 600mm c/c. in both directions using 2.0 mm. thick pre-
straightened GI wire laying ELITE BUTT EDGE ceiling tiles manufactured
by M/s. Armstrong World Industries, of size 600mmx600mmx14mm having
NRC 0.50, Light reflectance of >80% (WT), thermal conductivity k = 0.052-
0.057 W/m0K, Humidity Resistance of 90%, having Fire Performance CLASS
O / CLASS 1 (BS 476), surface having 3 coats of Vinyl Latex Paint over the
formed grid complete.
SPECIFICATION FOR ARMSTRONG CEILINGS – ORCAL LAY-IN
STANDARD PERFORATED MICROLOOK EDGE METAL TILE WITH
ACCOUSTICAL FLEECE WITH XL 15MM GRID.
Providing and fixing in true horizontal level 600 mm. X 600 mm. false ceiling
system manufactured by M/s. Armstrong World Industries using hot dipped
galvanized steel section, exposed surface with pre-coated capping, main tee
of size 15 x 32 mm., having 0.27 mm gauge at every 1200 mm. centre to
centre maximum and rotary stitched cross tee of size 15 x 32 mm, having
0.27 mm gauge at every 600 mm. c/c. and sub cross tee of size 15 x 32 mm,
having 0.25 mm gauge at 1200 mm c/c. and wall angle of size 19 x 19 mm.,
having 0.35 mm gauge fixed to the periphery of the wall. The above grid is
suspended at every 1200mm c/c. in both directions using 2.0 mm. thick pre-
straightened GI wire laying ORCAL LAY-IN STANDARD PERFOARTED
MICROLOOK EDGE METAL TILE WITH ACCOUSTICAL FLEECE
manufactured and punched in Single Process by M/s. Armstrong World
Industries, of size 600mmx600mmx0.5mm having NRC 0.70, Light
reflectance of >61% (WT), with standard perforation of 2.5 MM dia. (16%
open space), having Fire Performance CLASS O / CLASS 1 (BS 476), surface
having global white – baked polyester paint over the formed grid complete.
SPECIFICATION FOR ACCOUSTICAL FLEECE
The Acoustical Fleece (Fabric Backing) to be used in case of perforated
metal ceiling system should be “Soundtex” acoustic non-woven C 1986 SP as
manufactured by M/s. Freudenberg, Germany.
SPECIFICATION FOR BEAUTY SKY BUTT EDGE WITH XL 24MM GRID
Providing and fixing in true horizontal level 600 mm. X 600 mm. false ceiling
system manufactured by M/s. Armstrong World Industries using hot dipped
galvanized steel section, exposed surface with pre-coated capping, main tee
of size 24 x 32 mm., having 0.27 mm gauge at every 1200 mm. centre to
centre maximum and rotary stitched cross tee of size 24 x 27 mm, having
0.27 mm gauge at every 600 mm. c/c. and sub cross tee of size 24 x 27 mm,
having 0.25 mm gauge at 1200 mm c/c. and wall angle of size 19 x 19 mm.,
having 0.35 mm gauge fixed to the periphery of the wall. The above grid is
suspended at every 1200mm c/c. in both directions using 2.0 mm. thick pre-
straightened GI wire laying BEAUTY SKY BUTT EDGE ceiling tiles
manufactured by M/s. Armstrong World Industries, of size
600mmx600mmx14mm having NRC 0.5, Light reflectance of >80% (WT),
thermal conductivity k = 0.052 W/m0K, Humidity Resistance of 70% , having
Fire Performance CLASS A, surface having Factory Applied Vinyl Latex Paint
with back side - Sanded and having one coat of white paint over the formed
grid complete.
SPECIFICATION FOR BEAUTY SKY TEGULAR EDGE WITH RETAIL 24MM
GRID
Providing and fixing in true horizontal level 600 mm. X 600 mm. false ceiling system
manufactured by M/s. Armstrong World Industries using hot dipped galvanized
steel section, exposed surface with pre-coated capping, main tee of size 24 x 32
mm., having 0.27 mm gauge at every 1200 mm. centre to centre maximum and rotary
stitched cross tee of size 24 x 27 mm, having 0.27 mm gauge at every 600 mm. c/c.
and sub cross tee of size 24 x 27 mm, having 0.25 mm gauge at 1200 mm c/c. and
wall angle of size 19 x 19 mm., having 0.35 mm gauge fixed to the periphery of the
wall. The above grid is suspended at every 1200mm c/c. in both directions using 2.0
mm. thick pre-straightened GI wire laying BEAUTY SKY TEGULAR EDGE ceiling
tiles manufactured by M/s. Armstrong World Industries, of size
600mmx600mmx14mm having NRC 0.5, Light reflectance of >80% (WT), thermal
conductivity k = 0.052 W/m0K, Humidity Resistance of 70% , having Fire
Performance CLASS A, surface having Factory Applied Vinyl Latex Paint with back
side - Sanded and having one coat of white paint over the formed grid complete.
SPECIFICATION FOR ARMSTRONG CEILINGS – ELITE BUTT EDGE
(RH 99) WITH XL 24MM GRID
Providing and fixing in true horizontal level 600 mm. X 600 mm. false ceiling
system manufactured by M/s. Armstrong World Industries using hot dipped
galvanized steel section, exposed surface with pre-coated capping, main tee
of size 24 x 32 mm., having 0.27 mm gauge at every 1200 mm. centre to
centre maximum and rotary stitched cross tee of size 24 x 27 mm, having
0.27 mm gauge at every 600 mm. c/c. and sub cross tee of size 24 x 27 mm,
having 0.25 mm gauge at 1200 mm c/c. and wall angle of size 19 x 19 mm.,
having 0.35 mm gauge fixed to the periphery of the wall. The above grid is
suspended at every 1200mm c/c. in both directions using 2.0 mm. thick pre-
straightened GI wire laying ELITE BUTT EDGE ceiling tiles manufactured
by M/s. Armstrong World Industries, of size 600mmx600mmx15mm having
NRC 0.50, Light reflectance of >84% (WT), thermal conductivity k = 0.052-
0.057 W/m0K, Humidity Resistance of 99%, having Fire Performance CLASS
O / CLASS 1 (BS 476), surface having 3 coats of Vinyl Latex Paint over the
formed grid complete.
SPECIFICATION FOR ARMSTRONG CEILINGS – ELITE TEGULAR EDGE
(RH 99) WITH XL 24MM GRID
Providing and fixing in true horizontal level 600 mm. X 600 mm. false ceiling
system manufactured by M/s. Armstrong World Industries using hot dipped
galvanized steel section, exposed surface with pre-coated capping, main tee
of size 24 x 32 mm., having 0.27 mm gauge at every 1200 mm. centre to
centre maximum and rotary stitched cross tee of size 24 x 27 mm, having
0.27 mm gauge at every 600 mm. c/c. and sub cross tee of size 24 x 27 mm,
having 0.25 mm gauge at 1200 mm c/c. and wall angle of size 19 x 19 mm.,
having 0.35 mm gauge fixed to the periphery of the wall. The above grid is
suspended at every 1200mm c/c. in both directions using 2.0 mm thick pre-
straightened GI wire laying ELITE TEGULAR EDGE ceiling tiles
manufactured by M/s. Armstrong World Industries, of size
600mmx600mmx15mm having NRC 0.50, Light reflectance of >84% (WT),
thermal conductivity k = 0.052-0.057 W/m0K, Humidity Resistance of 99%,
having Fire Performance CLASS O / CLASS 1 (BS 476), surface having 3
coats of Vinyl Latex Paint over the formed grid complete.
SPECIFICATION FOR ARMSTRONG CEILINGS – ELITE MICROLOOK
EDGE (RH 99) WITH SILHOUETTE GRID
Providing and fixing false ceiling system manufactured by M/s. Armstrong
World Industries using hot dipped galvanized steel section, rotary stitched
main tee of size 15mm x 42 mm web height, having 0.36 mm gauge at every
600 mm centre to centre maximum and rotary stitched cross tee of size 15
mm x 42 mm, having 0.33 mm gauge at every 600 mm. c/c. and wall angle of
size 19 x 19 mm., having 0.35 mm gauge fixed to the periphery of the wall.
The above grid is suspended at every 600mm c/c. in both directions using 2.0
mm. thick pre-straightened GI wire laying ELITE MICROLOOK EDGE ceiling
tiles manufactured by M/s. Armstrong World Industries, of size
600mmx600mmx15mm having NRC 0.50, Light reflectance of >840 (WT),
thermal conductivity k = 0.052-0.057 W/m0K, Humidity Resistance of 99%,
having Fire Performance CLASS O / CLASS 1 (BS 476), surface having 3
coats of Vinyl Latex Paint over the formed grid complete.
SPECIFICATION FOR ARMSTRONG CEILINGS – ELITE MICROLOOK
EDGE (RH 99) WITH XL 15MM GRID
Providing and fixing in true horizontal level 600 mm. X 600 mm. false ceiling
system manufactured by M/s. Armstrong World Industries using hot dipped
galvanized steel section, exposed surface with pre-coated capping, main tee
of size 15 x 32 mm., having 0.27 mm gauge at every 1200 mm. centre to
centre maximum and rotary stitched cross tee of size 15 x 32 mm, having
0.27 mm gauge at every 600 mm. c/c. and sub cross tee of size 15 x 32 mm,
having 0.25 mm gauge at 1200 mm c/c. and wall angle of size 19 x 19 mm.,
having 0.35 mm gauge fixed to the periphery of the wall. The above grid is
suspended at every 1200mm c/c. in both directions using 2.0 mm. thick pre-
straightened GI wire laying ELITE MICROLOOK EDGE ceiling tiles
manufactured by M/s. Armstrong World Industries, of size
600mmx600mmx15mm having NRC 0.50, Light reflectance of >840 (WT),
thermal conductivity k = 0.052-0.057 W/m0K, Humidity Resistance of 99%,
having Fire Performance CLASS O / CLASS 1 (BS 476), surface having 3
coats of Vinyl Latex Paint over the formed grid complete.
SPECIFICATION FOR ARMSTRONG CEILINGS – CLASSIC LITE RH 90 BUTT
EDGE WITH XL 24MM GRID
Providing and fixing in true horizontal level 600 mm. X 600 mm. false ceiling system
manufactured by M/s. Armstrong World Industries using hot dipped galvanized
steel section, exposed surface with pre-coated capping, main tee of size 24 x 35
mm. at every 1200 mm. c/c. maximum and rotary stitched cross tee of size 24 x 27
mm at every 600 mm. c/c. and sub cross tee of size 24 x 25 mm at 1200 mm c/c.
and wall angle of size 19 x 19 mm fixed to the periphery of the wall. The above grid
is suspended at every 1200mm c/c. in both directions using 2.0 mm. thick pre-
straightened GI wire laying Classic Lite Butt Edge ceiling tiles manufactured by
M/s. Armstrong World Industries, having RH 90% & NRC of 0.5 and size
600mmx600mmx14mm over the formed grid complete.
SPECIFICATION FOR ARMSTRONG CEILINGS – CLASSIC LITE RH 95
TEGULAR EDGE WITH RETAIL 24MM GRID
Providing and fixing in true horizontal level 600 mm. X 600 mm. false ceiling system
manufactured by M/s. Armstrong World Industries using hot dipped galvanized
steel section, exposed surface with pre-coated capping, main tee of size 24 x 32
mm. at every 1200 mm. c/c. maximum and rotary stitched cross tee of size 24 x 27
mm at every 600 mm. c/c. and sub cross tee of size 24 x 25 mm at 1200 mm c/c.
and wall angle of size 19 x 19 mm fixed to the periphery of the wall. The above grid
is suspended at every 1200mm c/c. in both directions using 2.0 mm. thick pre-
straightened GI wire laying Classic Lite Tegular Edge ceiling tiles manufactured by
M/s. Armstrong World Industries, having RH 95% & NRC of 0.5 and size
600mmx600mmx15mm over the formed grid complete.
SPECIFICATION FOR ARMSTRONG CEILINGS – CLASSIC LITE RH 90
MICROLOOK EDGE WITH XL 15MM GRID.
Providing and fixing in true horizontal level 600 mm. X 600 mm. false ceiling system
manufactured by M/s. Armstrong World Industries using hot dipped galvanized
steel section, exposed surface with pre-coated capping, main tee of XL 15mm 3000
mm length at every 1200 mm. c/c. maximum and rotary stitched cross tee of
1200mm length at every 600 mm. c/c. and sub cross tee of 600mm length at every
1200 mm c/c. and wall angle of size 19 x 19 mm. fixed to the periphery of the wall.
The above grid is suspended at every 1200mm c/c. in both directions using 2.0 mm.
thick pre-straightened GI wire, laying Classic Lite Microlook Edge ceiling tiles
manufactured by M/s. Armstrong World Industries, having Humidity Resistance of
90%, NRC 0.50 and size 600mmx600mmx14mm over the formed grid complete.
SPECIFICATION FOR ARMSTRONG CEILINGS – CLASSIC LITE RH 90 BUTT
EDGE WITH WITH 15MM SELECT GRID
Providing and fixing in true horizontal level 600 mm X 600 mm false ceiling system
manufactured by M/s. Armstrong World Industries using hot dipped galvanized
steel section, rotary stitched main tee of size 15 mm x 30 mm web height, having
0.27 mm gauge at every 600 mm centre to centre maximum and rotary stitched
cross tee of size 15 mm x 30 mm, having 0.27 mm gauge at every 600 mm. c/c. and
wall angle of size 19 x 19 mm., having 0.35 mm gauge fixed to the periphery of the
wall. The above grid is suspended at every 600mm c/c. in both directions using 2.0
mm. thick pre-straightened GI wire laying Classic Lite Butt Edge ceiling tiles
manufactured by M/s. Armstrong World Industries, having RH 90% & NRC of 0.5
and size 600mmx600mmx14mm over the formed grid complete.
SPECIFICATION FOR ARMSTRONG CEILINGS – VisualV49 ML EDGE WITH
SELECT 15 MM GRID
Providing and fixing in true horizontal level 600 mm X 600 mm false ceiling system
manufactured by M/s. Armstrong World Industries using hot dipped galvanized
steel section, rotary stitched main tee of size 15 mm x 30 mm web height, having
0.27 mm gauge at every 600 mm centre to centre maximum and rotary stitched
cross tee of size 15 mm x 30 mm, having 0.27 mm gauge at every 600 mm. c/c. and
wall angle of size 19 x 19 mm., having 0.35 mm gauge fixed to the periphery of the
wall. The above grid is suspended at every 600mm c/c. in both directions using 2.0
mm. thick pre-straightened GI wire laying VisualV49 Microlook Edge Tile with
Select 15 MM Grid Ceiling Tiles manufactured by M/s. Armstrong World Industries,
of size 600mmx600mmx15mm having NRC 0.95, thermal conductivity k = 0.052-
0.057 W/m0K, Humidity Resistance of 70% , having Fire Performance CLASS O /
CLASS 1 (BS 476) over the formed grid complete.
SPECIFICATION FOR ARMSTRONG CEILINGS – METAL LAY-IN PLAIN
TILE WITH XL 15MM GRID.
Providing and fixing in true horizontal level 600 mm. X 600 mm. false ceiling
system manufactured by M/s. Armstrong World Industries using hot dipped
galvanized steel section, exposed surface with pre-coated capping, main tee
of size 15 x 32 mm., having 0.27 mm gauge at every 1200 mm. centre to
centre maximum and rotary stitched cross tee of size 15 x 32 mm, having
0.27 mm gauge at every 600 mm. c/c. and sub cross tee of size 15 x 32 mm,
having 0.25 mm gauge at 1200 mm c/c. and wall angle of size 19 x 19 mm.,
having 0.35 mm gauge fixed to the periphery of the wall. The above grid is
suspended at every 1200mm c/c. in both directions using 2.0 mm. thick pre-
straightened GI wire laying METAL LAY-IN PLAIN TILE manufactured and
punched in Single Process by M/s. Armstrong World Industries. The ceiling
Product shall be finished with a durable, electrostatic factory applied
polyster powder coat & Tile Module shall be of 600mm x 600mm x 0.5mm of
size - baked polyester paint over the formed grid complete.
SPEC. FOR STAINLESS STEEL METAL CEILING – CLIP-IN (PLAIN)
Providing and fixing of CLIP-IN STAINLESS STEEL METAL FALSE
CEILING with UNPERFORATED PLAIN surface Beveled edge tiles installed
on a single frame grid system by comprising of a MAIN CARRIER BAR at
every 600mm interval suspended from a “ C CHANNEL” at every 1000mm
interval using a HANGER CLIP system and Fixing a 19mm x 19mm WALL
ANGLE around the wall and suspending the “C Channel” using 2mm/3mm
adjustable G.I Wire or G.I Rod fixed to Roof using 6mm Nylon Rawal Plug and
Eye Hook or L Cleat at every 1200mm intervals at the C Channel. The ceiling
Tile Module shall be of 600mm x 600mm size manufactured by Armstrong
World Industries Ltd. clipped on from the bottom to the main carries bar.
SPECIFICATION FOR SOUNDSOAK ACOUSTICAL WALL PANELLING
Providing and fixing sound soak acoustical wall paneling of 21mm thick,
600mm wide and 2200mm long or approved size high density mineral fibre
boards having grooves on the side and covered with treated fabric (with fire
retardant & dirt repellant coating) fixed with concealed extruded powder
coated aluminum „H‟ spline, „J‟ moulding and other accessories, supports, etc.
of Armstrong World Industries make including necessary MDF frame work,
glass wool backing of density 32Kg/Cum all complete as per drawings.
SPECIFICATIONS FOR AXIOM PERIMETER TRIM
A) Product / Manufacturer: -
Axiom Perimeter Trim / Armstrong World Industries (India) Pvt. Ltd.
B) Components: -
1. Axiom Trim Channel : 50mm/100mm/150mm wide face with 19.3mm(+/-
0.50mm) horizontal legs, straight or curved sections with special bosses
formed for attachment to the Axiom tee-bar connection clip or hanging clip,
extruded Aluminum, factory finished (minimum 50 microns factory - applied
baked polyester paint).Aluminum Extrusions formed with distinct
architectural detail groove on top and bottom flanges and special bosses to
receive the tee bar connection clips and splice plates, to provide positive
mechanical lock with no visible fasteners.
2. Axiom Splice Plate: Formed to fit into special bosses in the Axiom and
locked in place with factory-installed screws. These Steel splice plates are
used to align and secure all joints between sections of Axiom trims. Each
joint in the 50mm section height will require one splice plate whereas 100
mm & 150mm Axiom trims will require 2 splice plate at each joint.
3. Axiom Tee-Bar Connection Clip: Commercial quality G.I formed to fit into
special bosses and locked in place by factory-installed screws and attached
to Armstrong (XL-24 / XL-15/Silhouette/Interlude) suspension system
members. T-Bar connection clips are used to attach the Axiom to the
supporting Suspension system members. These two-piece Aluminum clips are
supplied as an assembled unit with the steel locking screw factory installed.
One clip is required at each location where the grid system intersects the
Axiom trim.
C) Installation Procedure:
1. Hang the sections of Axiom Trim onto the grid system by engaging the top
ear of the connection clip under the boss of the channel trim. Slide the
lower leg downward to engage the lower boss on the trim and secure by
tightening the locking screw.
2. Complete the installation of all channel trims sections. Install and secure the
splice plates.
3. Make adjustments as necessary to properly align the complete installation.
SPECIFICATIONS FOR METAL CEILING – CLIP-IN (PERFORATED
TILES)
Providing and fixing of CLIP-IN METAL FALSE CEILING TILES with
PERFORATIONS with BLACK ACOUSTICAL FLEECE installed on a Double
frame grid system comprising of a MAIN CARRIER BAR at every 600mm
interval suspended from a “ C CHANNEL” at every 1000mm interval using a
HANGER CLIP system and Fixing a 19mm x 19mm WALL ANGLE around the
wall and suspending the “C Channel” using 2mm/3mm adjustable G.I Wire or
G.I Rod fixed to Roof using 6mm Nylon Rawal Plug and Eye Hook or L Cleat at
every 1200mm intervals at the C Channel. The ceiling Tile Module shall be of
600mm x 600mm size manufactured out of Pre-coated hot dipped Galvanized
steel with a primer and finish coat of Standard GLOBAL WHITE Polyester
Tile with STANDARD PERFORATION of 2.5mm dia. Holes with 16% OPEN
AREA CEILING PANEL or MICRO PERFORATION of 1.5mm dia. Holes with
22% open area CEILING PANEL, clipped on from the bottom to the MAIN
CARRIER BAR.
SPECIFICATIONS FOR METAL CEILING – CLIP-IN (PLAIN)
Providing and fixing of CLIP-IN METAL FALSE CEILING with
UNPERFORATED PLAIN surface Beveled edge tiles installed on a double
frame grid system by comprising of a MAIN CARRIER BAR at every 600mm
interval suspended from a “ C CHANNEL” at every 1000mm interval using a
HANGER CLIP system and Fixing a 19mm x 19mm WALL ANGLE around the
wall and suspending the “C Channel” using 2mm/3mm adjustable G.I Wire or
G.I Rod fixed to Roof using 6mm Nylon Rawal Plug and Eye Hook or L Cleat at
every 1200mm intervals at the C Channel. The ceiling Tile Module shall be of
600mm x 600mm size manufactured out of Pre-coated hot dipped Galvanised
steel with a primer and finish coat of Standard GLOBAL WHITE Polyester
painted panel, clipped on from the bottom to the MAIN CARRIER BAR.
SPECIFICATION FOR ACCOUSTICAL FLEECE
The Acoustical Fleece (Fabric Backing) to be used in case of perforated
metal ceiling system should be “Soundtex” acoustic nonwoven C 1986 SP as
manufactured by M/s. Freudenberg, Germany.
SPECIFICATIONS FOR KNIFE EDGE AXIOM PERIMETER TRIM
A) Product / Manufacturer: -
Axiom Perimeter Trim / Armstrong World Industries (India) Pvt. Ltd.
B) Components: -
1. Axiom Trim Channel : Knife Edge axiom with 150mm wide bottom face with
straight with special bosses formed for attachment to the Axiom tee-bar
connection clip or hanging clip, extruded Aluminum, factory finished
(minimum 50 microns factory - applied baked polyester paint).Aluminum
Extrusions formed with distinct architectural detail groove on top and
bottom flanges and special bosses to receive the tee bar connection clips
and splice plates, to provide positive mechanical lock with no visible
fasteners.
2. Axiom Splice Plate: Formed to fit into special bosses in the Axiom and
locked in place with factory-installed screws. These Steel splice plates are
used to align and secure all joints between sections of Axiom trims. Each
joint in the 50mm section height will require one splice plate whereas 100
mm & 150mm Axiom trims will require 2 splice plate at each joint.
3. Axiom Tee-Bar Connection Clip: Commercial quality G.I formed to fit into
special bosses and locked in place by factory-installed screws and attached
to Armstrong (XL-24 / XL-15/Silhouette/Interlude) suspension system
members. T-Bar connection clips are used to attach the Axiom to the
supporting Suspension system members. These two-piece Aluminum clips
are supplied as an assembled unit with the steel locking screw factory
installed. One clip is required at each location where the grid system
intersects the Axiom trim.
4. Alignment Plate: Formed to fit to the flat face of the axiom between the
special notch provided in the section and the web of the perimeter trim.
5. Corner pieces: knife edge axiom sections swept in 90 degrees used for
finished corners connected to the main trim channel by means of a splice
plate.
C) Installation Procedure:
1. Hang the sections of Axiom Trim onto the grid system by engaging the top
ear of the connection clip under the boss of the channel trim. Slide the
lower leg downward to engage the lower boss on the trim and secure by
tightening the locking screw.
2. Complete the installation of all channel trims sections. Install and secure
the splice plates, corner pieces, alignment plates etc.
3. Make adjustments as necessary to properly align the complete installation.
SPECIFICATIONS FOR BANDRASTER SUSPENSION SYSTEM
Providing and fixing of Armstrong Bandraster suspension system manufactured and
supplied by Armstrong World Industries comprising main Bandraster sections made
our of pre-coated galvanized steel painted in Armstrong Global White Colour of
length 3600mm, web height of 38mm, face width of 50mm/100mm and having
projections of 12mm to receive the tile to be placed at required intervals and
connected to the slab soffit/roof using Nonius hangers or anchor fasteners and
6mm diameter threaded rod connected to the main Bandraster section using a
strip/rod connector at every 1200 mm interval minimum. The Bandraster sections of
longer length to be connected using a splice plate and secured to the wall using wall
connectors. The main Bandraster sections shall have slots at every 100mm intervals
to receive Armstrong Prelude 24 mm grids running in perpendicular direction to the
main sections and cross connectors that rest on the web of the main section to
draw perpendicular Bandraster sections from the main sections etc. complete.
SPECIFICATION FOR ARMSTRONG CEILINGS – LAY-IN PERFORATED MICROLOOK EDGE
METAL TILE WITH ACCOUSTICAL FLEECE WITH XL 15MM GRID.
Providing and fixing in true horizontal level 600 mm. X 600 mm. false ceiling system manufactured by
M/s. Armstrong World Industries using hot dipped galvanized steel section, exposed surface with pre-
coated capping, main tee of size 15 x 32 mm., having 0.27 mm gauge at every 1200 mm. centre to
centre maximum and rotary stitched cross tee of size 15 x 32 mm, having 0.27 mm gauge at every 600
mm. c/c. and sub cross tee of size 15 x 32 mm, having 0.25 mm gauge at 1200 mm c/c. and wall angle of
size 19 x 19 mm., having 0.35 mm gauge fixed to the periphery of the wall. The above grid is suspended
at every 1200mm c/c. in both directions using 2.0 mm. thick pre-straightened GI wire laying ORCAL
LAY-IN STANDARD PERFOARTED MICROLOOK EDGE METAL TILE WITH ACCOUSTICAL
FLEECE manufactured and punched in Single Process by M/s. Armstrong World Industries, of size
600mmx600mmx0.5mm having NRC 0.70, Light reflectance of >61% (WT), with standard perforation
of 2.5 MM dia. (16% open space), having Fire Performance CLASS O / CLASS 1 (BS 476), surface
having global white – baked polyester paint over the formed grid complete.
\
SPECIFICATION FOR ARMSTRONG CEILINGS – METAL LAY-IN PLAIN TILE WITH XL 15MM
GRID.
Providing and fixing in true horizontal level 600 mm. X 600 mm. false ceiling system manufactured by
M/s. Armstrong World Industries using hot dipped galvanized steel section, exposed surface with pre-
coated capping, main tee of size 15 x 32 mm., having 0.27 mm gauge at every 1200 mm. centre to
centre maximum and rotary stitched cross tee of size 15 x 32 mm, having 0.27 mm gauge at every 600
mm. c/c. and sub cross tee of size 15 x 32 mm, having 0.25 mm gauge at 1200 mm c/c. and wall angle of
size 19 x 19 mm., having 0.35 mm gauge fixed to the periphery of the wall. The above grid is suspended
at every 1200mm c/c. in both directions using 2.0 mm. thick pre-straightened GI wire laying METAL
LAY-IN PLAIN TILE manufactured and punched in Single Process by M/s. Armstrong World
Industries. The ceiling Product shall be finished with a durable, electrostatic factory applied polyster
powder coat & Tile Module shall be of 600mm x 600mm x 0.5mm of size - baked polyester paint over
the formed grid complete.
GUIDE SPECIFICATION FOR ARMSTRONG CORTEGA MICROLOOK CEILING WITH
ARMSTRONG SUPRAFINE 15MM GRID SYSTEM
Providing and fixing in true horizontal level Armstrong CORTEGA RH99 microlook edge ceiling tiles of
size 600mmx600mmx16mm having NRC 0.55, Light reflectance of >80% (WT), thermal conductivity k =
0.052-0.057 W/m0K, Humidity Resistance of 99% RH, and having Fire Performance CLASS 0/Class 1
(BS 476). The tile shall be laid on Armstrong grid systems with 15mm wide T - section flanges colour
white having rotary stitching on the Main Runner, 1200 mm & 600 mm Cross Tees.
INSTALLATION: To comprise main runner spaced at 1200mm centres securely fixed to the
structural socket by approved hanger at 1200mm maximum centre. The last hanger at the end of each
main runner should not be greater than 450mm from the adjacent wall.
Flush fitting 1200mm long cross tees to be interlocked between main runners at 600mm centre to
form 1200 x 600 mm module. Cut cross tees longer than 600mm require independent support. 600 x
600mm module to be formed by fitting 600mm long flush fitting cross tees centrally between the
1200 mm cross tees.
Perimeter trim to be Armstrong wall angles or channel, secured to walls at 450 mm maximum centres.
GUIDE SPECIFICATION FOR ARMSTRONG CORTEGA MICROLOOK CEILING WITH
ARMSTRONG SILHOUETTE GRID
Providing and fixing in true horizontal level Armstrong CORTEGA RH99 microlook edge ceiling tiles of
size 600mmx600mmx16mm having NRC 0.55, Light reflectance of >80% (WT), thermal conductivity k =
0.052-0.057 W/m0K, Humidity Resistance of 99% RH, and having Fire Performance CLASS 0/Class 1
(BS 476). The tile shall be laid on Armstrong Silhouette profile grid system with 15mm white flanges
incorporating a 6mm central reveal in white/black colour. Silhouette, Main Runners & Cross Tees to
have mitred ends & “birdsmouth” notches to provide mitred cruciform junctions.
INSTALLATION : To comprise main runner spaced at 1200mm centres securely fixed to the
structural soffit by approved hangers at 1200mm maximum centre & not more than 150mm from
spliced joints. The last hanger at the end of each main runner should not be greater than 600mm from
the adjacent wall.
1200mm long cross tees to be interlocked between main runners at 600mm centre to form 1200 x 600
mm module. Cut cross tees longer than 600mm require independent support. 600 x 600mm modules to
be formed by fitting 600mm long cross tees centrally between the 1200 mm cross tees. The 1200mm
cross tees to have central “birdsmouth” notches to facilitate fitting of 600mm cross tees.
Perimeter trim to be Armstrong wall angles, secured to walls at 450 mm maximum centres.
GUIDE SPECIFICATION FOR ARMSTRONG CORTEGA BOARD/TEGULAR CEILING WITH
ARMSTRONG XL 24 mm GRID SYSTEM
Providing & Fixing in true horizontal level Armstrong Acoustical Suspended Ceiling System with
CORTEGA RH99 (Board / Tegular ) Tiles. The tiles should have Humidity Resistance of 99% RH,
Average NRC .55, Light Reflectance >80%, Thermal Conductivity k = 0.052 – 0.057 w/mc, Color White,
Fire Performance Class 0/Class 1 (BS - 476) in module size of 600mm x 600mm x 16 mm laid on 24XL -
Hot Dipped Galvanized steel suspension System having rotary stitching on the Main Runner, 1200 mm &
600 mm Cross Tees.
INSTALLATION: To comprise main runner spaced at 1200mm centres securely fixed to the structural
socket by approved hanger at 1200mm maximum centre. The last hanger at the end of each main
runner should not be greater than 450mm from the adjacent wall.
Flush fitting 1200mm long cross tees to be interlocked between main runners at 600mm centre to
form 1200 x 600 mm module. Cut cross tees longer than 600mm require independent support. 600 x
600mm module to be formed by fitting 600mm long flush fitting cross tees centrally between the
1200 mm cross tees.
Perimeter trim to be Armstrong wall angles or channel, secured to walls at 450 mm maximum centres.
GUIDE SPECIFICATION FOR ARMSTRONG OPTRA MICROLOOK SOFT FIBRE CEILING WITH
ARMSTRONG SUPRAFINE 15MM GRID
Providing and fixing in true horizontal level Armstrong OPTRA microlook edge ceiling tiles with glass
fiber substrate of size 600mmx600mmx15mm having NRC 0.90, Light reflectance of >80% (WT),
thermal conductivity k = 0.040 W/m0K, Humidity Resistance of 95% RH, and having Fire Performance
CLASS 1 (BS 476). The tile shall have a front facing of white scrim tissue of 180 gsm and 45 gsm
formaldehyde free fiber tissue backing and shall be laid on Armstrong grid systems with 15mm wide T
- section flanges colour white having rotary stitching on the Main Runner, 1200 mm & 600 mm Cross
Tees.
INSTALLATION: To comprise main runner spaced at 1200mm centres securely fixed to the
structural socket by approved hanger at 1200mm maximum centre. The last hanger at the end of each
main runner should not be greater than 450mm from the adjacent wall.
Flush fitting 1200mm long cross tees to be interlocked between main runners at 600mm centre to
form 1200 x 600 mm module. Cut cross tees longer than 600mm require independent support. 600 x
600mm module to be formed by fitting 600mm long flush fitting cross tees centrally between the
1200 mm cross tees.
Perimeter trim to be Armstrong wall angles or channel, secured to walls at 450 mm maximum centres.
GUIDE SPECIFICATION FOR ARMSTRONG OPTRA MICROLOOK SOFT FIBRE CEILING WITH
ARMSTRONG SILHOUETTE GRID
Providing and fixing in true horizontal level Armstrong OPTRA glasswool microlook edge ceiling tiles of
size 600mmx600mmx15mm having NRC 0.90, Light reflectance of >80% (WT), thermal conductivity k =
0.040 W/m0K, Humidity Resistance of 95% RH, and having Fire Performance CLASS 1 (BS 476). The
tile shall have a front facing of white scraped tissue of 180 gsm and 45 gsm formaldehyde free fiber
tissue backing and shall be laid on Armstrong Silhouette profile grid system with 15mm white flanges
incorporating a 6mm central reveal in white/black colour. Silhouette, Main Runners & Cross Tees to
have mitred ends & “birdsmouth” notches to provide mitred cruciform junctions.
INSTALLATION : To comprise main runner spaced at 1200mm centres securely fixed to the
structural soffit by approved hangers at 1200mm maximum centre & not more than 150mm from
spliced joints. The last hanger at the end of each main runner should not be greater than 600mm from
the adjacent wall.
1200mm long cross tees to be interlocked between main runners at 600mm centre to form 1200 x 600
mm module. Cut cross tees longer than 600mm require independent support. 600 x 600mm modules to
be formed by fitting 600mm long cross tees centrally between the 1200 mm cross tees. The 1200mm
cross tees to have central “birdsmouth” notches to facilitate fitting of 600mm cross tees.
Perimeter trim to be Armstrong wall angles, secured to walls at 450 mm maximum centres.
GUIDE SPECIFICATION FOR ARMSTRONG OPTRA SL2 CONCEALED EDGE SOFT FIBRE
CEILING WITH ARMSTRONG PRELUDE XL24 GRID
Providing and fixing in true horizontal level Armstrong OPTRA glass wool SL2 concealed edge ceiling
tiles of size 600mmx600mmx20/25mm having NRC 0.90, Light reflectance of >80% (WT), thermal
conductivity k = 0.040 W/m0K, Humidity Resistance of 95% RH, and having Fire Performance CLASS 1
(BS 476). The tile shall have a front facing of white scraped tissue of 180 gsm and 45 gsm
formaldehyde free fiber tissue backing and shall be laid on Armstrong Prelude XL 24 profile grid
system with 24mm wide T - section flanges colour white having rotary stitching on the Main Runners.
INSTALLATION: To comprise main runner spaced at 600mm centres securely fixed to the structural
soffit by approved hangers at 600mm maximum centre & not more than 150mm from spliced joints.
The last hanger at the end of each main runner should not be greater than 600mm from the adjacent
wall.
Spacer bars to be placed over the formed row of grids (by cutting notches at 600mm centre to centre
in the wall angle over the bulb of the main runners) at every 600 mm interval max.
Perimeter trim to be Armstrong wall angles, secured to walls at 450 mm maximum centres.