System Control Module Total Access 5000® System Control Module Bridging
Product Features■ Front-access 10/100Bt
Ethernet port
■ Rear-access 10/100Bt Ethernet port
■ Bridging between Ethernet and inband network interfaces
■ Auto Upgrade for maintaining system software release versions
■ System Controlled Reboot to minimize network downtime during system upgrades
■ DHCP Server for local management
■ CLI support
■ Web-based GUI support
■ RFC3164 syslog
■ RADIUS and TACACS+ Authentication
■ Trusted IP client restriction
■ Complex password enforcement
■ Account lockout/expiration
■ Password aging
■ Secure Telnet (SSHv2) support
■ Non-volatile system event log for security access and administration tracking
■ Secure FTP, FTP, and TFTP support
■ TSCAN diagnostics
■ Hot-swappable
■ Extended temperature hardened components (-40°C to +65°C)
■ Shelf configuration storage
■ NEBS compliant
The ADTRAN® Total Access 5000 System Control Module (SCM) Bridging facilitates flexible, economical management while supporting both local and remote provisioning. The card is hot-swappable
and provides console access and alarm
contact closures.
The SCM Bridging provides for remote
management through SNMP and TL1. TL1 and
SNMP access are provided as in-band IP over
Ethernet. Additionally, SNMP and TL are both
supported out-of-band through one of two
10/100Bt Ethernet connections on the front of
the card. Telnet remote console access is also
provided. The front panel Ethernet-2 interface
supports a configurable DHCP server that
provides a DHCP pool to connected systems.
This will allow users to automatically connect
to the System Controller Module and manage
the system through the Web-based Graphical
User Interface (GUI) or Command Line
Interface (CLI).
The Ethernet interfaces support Auto-MDX
configuration for 10Base-T and 100/Base-T
operation. Only one Ethernet port can be
utilized with the DHCP server at given time.
The SCM Bridging provides the capability
to establish an Ethernet bridge between one
of the 10/100 Base-T Ethernet ports and the
in-band network interface. This capability
provides operators with the option to connect
the Central Office (CO) Total Access 5000
System Controller to their CO LAN while
maintaining a dedicated in-band management
Virtual LAN (VLAN) for their remote terminal
Total Access 5000 systems.
The SCM Bridging supports a wide range of
security options for local and remote authen-
tication. A maximum of 15 local accounts
are supported with password aging, account
expiration, complex password, and invalid
login support. For remote authentication, the
SCM Bridging supports Remote Authentication
Dial-In User Service (RADIUS) and Terminal
Access Controller Access –Control System Plus
(TACACS+). The system supports the ability
to choose which authentication method has
priority as well as the ability to choose the fall
back method of authentication should one or
more login operations fail.
The SCM Bridging is the central point for
firmware upgrades through the use of Auto
Upgrade and System Controlled Reboot (SCR).
Auto Upgrade provides a way for customers
to easily manage system releases across large
or small networks. Auto Upgrade is supported
through local configuration and management
or through the Total Access EMS. SCR provides
enhanced control of the Auto Upgrade process
such that the entire system will have a coordi-
nated reboot to the new system release. SCR
minimizes network down time and also allows
network administrators to prepare a system for
upgrade during normal business hours while
staging the system reboot during their
maintenance window.
For the SCM Bridging, one front access
10/100Bt Ethernet interface is provided in
addition to the local RS-232 DB-9 console port
(CRAFT) as well as two rear DB-9 console ports
(ADMIN and Network Management) for local
connectivity. The rear SMIO3 module provides
connections for the 16 external alarm inputs as
well as critical, major, and minor audible and
visual alarms contact closures.
Additionally, the SCM Bridging maintains
a copy of the provisioning for each module in
the shelf. In the event of a module exchange,
the previous provisioning information will
be restored if the new module is the same
type. The SCM Bridging supports multiple
file transfer methods including TFTP, FTP, File
Transfer over TL1 (FTOT®), and Secure FTP.
Smart Solutions for aConnected World.
ADTRAN, Inc.901 Explorer Boulevard
Huntsville, AL 35806
P.O. Box 140000Huntsville, AL 35814-4000
256 963 8000 voice256 963 8030 fax
General Information800 9ADTRAN
info@adtran.comwww.adtran.com
Pre-Sales Technical Support
888 5ADTRAN support@adtran.com
www.adtran.com/support
Where to Buy800 827 0807
www.adtran.com/where2buy
Post-Sales Technical Support
800 726 8663support@adtran.com
www.adtran.com/support
Regional OfficesDallas, TX
972 830 9070Denver, CO
303 471 9150Kansas City, KS
800 471 8649Newark, NJ800 471 8656
Ontario, Canada416 290 0585
Quebec, Canada877 923 8726
San Antonio, TX888 223 7671
International Inquiries+1 256 963 8716 voice
+1 256 963 6300 faxinternational@adtran.com
www.adtran.com/international
ADTRAN is an ISO 9001, ISO 14001 and a TL 9000 certified supplier.
TL19.1270
Product SpecificationsMechanicalDimensions
■Height: 9.25 inches■Width: 0.8 inches■Depth: 9.5 inches
Weight■0.65 lbs/272.155 g
Interfaces■Craft: DB-9 RS-232 Electrical Interface■ADMIN: DB-9 RS-232 DTE Electrical Interface■Network Management Port: DB-9 RS-232 DTE
Electrical Interface■Ethernet 10/100Bt interface (REAR)■Ethernet-2 10/100Bt interface (FRONT)■CR/MJ/MN Audible and Visual Alarm relay
contact closures■16 External Alarm inputs
International standards■NEBS■GR-1089 CORE■GR-63 CORE■NRTL Listed■FCC Part 15■AS/NZS60950
Management■Remote management through SNMP, TL1, Telnet,
SSH, Web GUI, and CLI■Ethernet interface(s) for SNMP, TL1, Telnet, SSH,
Web GUI, and CLI■Local Craft, ADMIN, and NTWK management ports
Environmental■Operating Temperature: -40°C to +65°C■Storage Temperature: -40°C to +80°C ■Relative Humidity: Up to 95%, non-condensing
Ordering InformationEquipment Part #
Total Access 5000 SCM 1187011G1
System Control ModuleTotal Access® 5000 System Control Module Bridging
Specifications subject to change without notice. ADTRAN and Total Access are registered trademarks of ADTRAN, Inc. All registered trademarks and trade-marks mentioned in this publication are the property of their respective owners.
61187011G1-8A August 2009Copyright © 2009 ADTRAN, Inc.
All rights reserved.
Voice/Data/Video
GPON
POTS & DSL
Central Office
Remote Terminal
10/100Base-T
10/100Base-T
RS-232C
Voice/Data/Video
GPONPOTS & DSL
Ethernet
Total AccessEMS
VT100Terminal
SNMPManagementStation
top related