tales from the toilet
Post on 25-Feb-2016
60 Views
Preview:
DESCRIPTION
TRANSCRIPT
TALES FROM THE TOILET
COLLECTION SYSTEM MAINTENANCESEWER JETTING,TELEVISING
& LINING
OCTOBER 10, 2011 IAWPCO NORTHEAST REGIONAL
CONFERENCE THE GAS LITE MANOR
AURORA, IL
APRIL 16 – 19, 2012 IAWPCO ANNUAL CONFERENCE
CROWNE PLAZA SPRINGFIELD, IL
DATES TO REMEMBER
PREVENT PUBLIC HEALTH HAZARD PROTECT THE ENVIRONMENT PREVENT DAMAGE TO PUBLIC OR PRIVATE
PROPERTY MINIMIZE COMPLAINTS REDUCE EXPENDITURES FOR
EMERGENCIES EXPOSE DIFFICIENCIES PROVIDE RELIABLE SERVICE
WHY MAINTAIN THE COLLECTION SYSTEM?
HOW MUCH CAN YOU ACCOMPLISH IN ONE DAY?
FOOTAGE/DAY x DAYS/WEEK x 50 WEEKS/YEAR
IS THAT REASONABLE?
NOPE!
GETTING STARTED
MANPOWER REQUIREMENTSManpower Requirements
Employees Position
1Superintendent
2Illinois Certified Lead Operators
6Illinois Certified Operators
Hours/Year JOB FUNCTION
18720Annual Available Man-hours for nine (9) Full Time Employees Estimated TOTAL Benefits for the six Full Time Employees (HOURS)
1520 Vacation Time792 Holiday hrs
864Sick Time
200Comp Time (est.)
144 Paid dayd off3520 Total hours
Labor hours per work year (250 work days)
3600 System One - Bio-Solids handling
4200System Two - Process/Excess ( including sampling/operation, review of analysis,reports and disinfection)
4500Collection system maintenance/televising
4000Equipment Maintenance/Repair, Building and Grounds, Interdepartmental Help
760Weekend duty/Overtime
120Callouts
1800 Supervision
Actual required hours
21,840ANNUAL Labor Hours for the 9 man crew
2080One Full-Time-Equivalent equals hours/yr
18720Available Man-hours for 6 man crewHours not justified for 3,650/YEAR
9.06 JUSTIFIED Full Time Equivalents (man/days)
STREET/ADDRESS ATLAS
STREET/ADDRESS ATLAS
INVENTORY OF THE SYSTEM
YES, I CAUGHT H*LL FOR THE FLAMES
CAMERA TRUCK
THE TOYS
THE CONTROLS
VARIOUS NOZZLES
SPINNERS
CHAIN/ROOT CUTTER
THE BEAST
WEEPING WILLOW
SILVER MAPLE
TONSILS
ROOT BALL
CRUSHED TILE
WHAT A MESS
MORE CRUSHED PIPE
LATERAL CONNECTION
WHAT THE? WHO THE?
OFFSET JOINT
IS THIS PIPE ROUND?
NOW HERE’S A PROPER INSTALLATION,,,,,,,,NOT
LATERAL CUTOUT
OH MY
POST LINING ROOTS THROUGH LATERAL
MORE POST LINING ROOTS
MORE POST LINING ROOTS
WRINKLED LINER
MINERAL DEPOSIT
ROOT MASS
PORCUPINE?
ROOT INTRUSION AT JOINT
ALMOST CLEAN
CUTTING ROOTS
NICOR, HMMM
PLUMBERS DO LEAVE THEIR WORK BEHIND
TELEVISING REPORT
COMPLETE TELEVISING REPORT
PRE-LINING REPORT WITH SERVICE CONNECTIONS
POST-LINING REPORT WITH SERVICE CONNECTION RESTORED
PRE-LINING REPORT WITH ROOTS
POST-LINING REPORT WITH ROOTS
PARTIAL TELEVISING REPORT
CONCRETE TRUCK WASHED OUT IN SANITARY SEWER
Date Address IMPORTANT NOTICE The potential for a sewage backup within your home was recently discovered during a routine inspection of Village owned
sanitary sewers. We urge you to review the following information and enclosures, as scheduled maintenance can avoid an unplanned emergency.
A closed circuit camera is inserted into a manhole in the street to “crawl” up our sewer mains to televise and record pipe
conditions. We use this information to prioritize and schedule pipe repairs in our municipal system. During the inspection of our sewer, private connections are obviously seen as the camera passes by.
The photo enclosed shows a severe grease and/or root accumulation in your sewer service line near the point of connection to
the Village sewer. We suggest a licensed plumber be called upon to rod your service line. Without service, the blockage will eventually restrict flow to the point of causing a sewage backup. The property owner is responsible for the pipe from the home to and including the connection at the Village sewer, according to the Roselle Code of Ordinances.
Should you desire additional information, please contact our Wastewater Division personnel at (630) 980-2024. John LaRocca Rob Burns Superintendent of Public Works Director Wastewater Operations Enclosure: Photo and brochure
CORRESPONDENCE
ROOT INTRUSION THROUGH A PVC PIPE
INFILTRATION
GREASE IS THE WORD
MORE GREASE
DIRECTIONAL BORING BY COM ED
PEEK-A-BOO
YEAR FOOTAGE 2000 - 13,320 2001 - 24,866 2002 - 3,323 2003 - 14,944 2004 - 12,220 2005 - 15,371 2006 - 11,325 2007 - 9,200 2008 - 7,454 2009 - 7,351 2010 - 10,452 TOTAL - 134,846 FEET –
25.53 MILES
SANITARY SEWERS CLEANED AND TELEVISED
YEAR FOOTAGE 2000 ------------------------------------ 2,048 2001 ------------------------------------ 0 2002 ------------------------------------ 2,831 2003 ------------------------------------ 797 2004 ------------------------------------ 12,215 2005 ------------------------------------ 5,544 2006 ------------------------------------ 25,772 2007 ------------------------------------ 16,261 2008 ------------------------------------ 13,042 2009 ------------------------------------ 8,474 2010 ------------------------------------ 3,811 TOTAL ---------------------------------- 90,895 FEET –
17.21 MILES
SANITARY SEWER LINED
Manhole # Location Frequency DateSection A4246 Marion & Devon QTR March 7, 2011 1611 Marion & Devon QTR MARCH 7, 20114219 Irving & Lincoln SEMI - ANNUAL MARCH 14, 2011
Section B5306 Granville & Lake view Ct. SEMI - ANNUAL APRIL 11, 20112650 Glacier Bay/Glacier Trail SEMI - ANNUAL APRIL 11, 20112641 Glacier Trail SEMI - ANNUAL APRIL 11, 2011 5263 Forum Drive SEMI - ANNUAL APRIL 14, 20114410 Bokelman St. & Irving Park SEMI – ANNUAL APRIL 14, 20114431 225 Park Lane QTR APRIL 15, 20114487 295 Park Lane QTR APRIL 15, 20115299 703 Parkview Ct. SEMI ANNUAL MAY 9, 20112674 558 White Sands Bay SEMI – ANNUAL MAY 9, 20114404 224 Irving Park QTR MAY 9, 20115278 702 Circle Dr. ANNUAL MAY 9, 2011
Trouble spots
TOY DISPLAY AT LIBRARY
TOYS
TOYS
HEIRLOOM NECKLACE
HEIRLOOM NECKLACE
DO WHAT YOU CAN SOMETHING IS BETTER THAN NOTHING AT LEAST LOCATE AND MAINTAIN THE
TROUBLE SPOTS COMMUNICATE WITH YOU RESIDENTS THE SUBTERRANEAN WORLD NEEDS
MAINTENANCE AND AWAYS, HAVE A GREAT DAY THANK YOU, THE WRITTEN TEST WILL
FOLLOW
CONCLUSION
top related