Technology Solutions
796 Tek DriveCrystal Lake, IL 60014 USA
Tel: +1 847 857 6076, +1 847 655 7428Fax: +1 847 655 6147
www.tek-trol.com
Flow | Level | Temperature | Pressure | Valves | Analyzers | Accessories | TekValSys
State-of-the-art measurement solutions
We offer multiple flow measurement technologies to measure liquids, gas-
es, steam and corrosive fluidOur specialized level measurement
instruments consists of contact, non-contact, differential, and
ultrasonic, to cater to all types of varied process needs
Our field and panel mount designsoffer an array of technologies to
choose from
Flow Measurement
Level Measurement
Temperature Measurement
Pressure Measurement
AccessoriesTekValSys
02 03
Our pressure measurement ranges provide compelling
accuracy and reliability
To improve the efficiency and
durability of a product additional accessories
are always of great importance
Diagnostic systems that provide real time validation and
monitoring
A full line of digital panel meters,
indicators and control instrumentation for
process indication and control
Flow Measurement
Level Measurement
Temperature Measurement
Pressure Measurement
AccessoriesTekValSys
INDICATOR CONTROLLER
TEKVALSYSACCESSORIESPRESSUREMEASUREMENT
Technology Solutions For Process Measurement Automation & Control
04 05
Flow Measurement
Tek-Trol’s range of flowmeter monitors mass and volumetric flow of liquids, gases and steam with
premium accuracy, high stability and robust operation
06
Coriolis Mass Flowmeter - Tek-Cor 1100A
Electromagnetic Flowmeter - Tek-Flux 1400A
Service Liquids and Gas
Wetted Material 304 SS, 316 SS or Hastealloy CAccuracy 0.1% or 0.2% or 0.5%Ranges For mass flow rates please refer the catalogRepeatability For 0.1% accuracy: ±0.05%, For 0.2% OutputDigital Communication
4 to 20 mA PulseRS 485 or HART
Temperature Limit Direct Mount: -58°F to 257°F (-50°C to 125°C)Remote Mount: -58°F to 392°F (-50°C to 200°C)
Power Requirements 18 to 28 VDC or 85 to 220 VACProcess Connections Flanges, Tri-Clamp or Threads, DIN or ANSIResolution/ Display OLED DisplayPressure Limits See ManualEnclosure Ratings NEMA 4 x (IP67), 7, 9Agency Approval UL ClassⅠ, DivⅠWeight See Manual
Service Compatible conductive liquids
Wetted Material Electrode Material: 316 SS or Hastealloy CLiner Materials: PTFE or Hard Rubber
Accuracy ±0.5% of F. S.Ranges For flow range please refer the catalogRepeatability 0.15% and PulseOutput 4 to 20 mA; optional HART, Pulse or RS 485Temperature Limit Sensor (Remote Mount): -50°F to 158°F (-45°C to 70°C)
Converter: -40°F to 122°F (-40°C to 50°C)Direct Mount: 40°F to 122°F (-40°C to 50°C)
Power Requirements 18 to 28 VDC or 85 to 220 VACProcess Connections 150# to 900# ANSIResolution/ Display LCD displayPressure Limits ≤ 150 PSIEnclosure Ratings IP68Weight See ManualAgency Approval CE
07
08
Vortex Flowmeter - Tek-Vor 1300C
Thermal Mass Flowmeter - Tek-Thermal 1700B
Service Air and NitrogenWetted Material 316 SS
Accuracy ±0.5% of FSFlow Velocity Ranges See Velocity ranges in CatalogRepeatability 0.2%
Output 4 to 20 mA with Pulsed output; Optional HART or RS 485Temperature Limit -40°F to 302°F (-40°C to 150°C)Power Requirements 13.5 VDC to 42 VDC
Process Connections 1/2" NPT
Resolution/ Display 5 Digit Display
Pressure Limits 232 PSI (16 bar)Enclosure Ratings IP65Weight See Manual
09
Ultrasonic Clamp-On Flowmeter - Tek-Clamp 1200A
Service Liquids, Gas, and Steam
Wetted Material 304 SS and 316 SS
Accuracy ±1% of reading
Ranges Gas: 197 ft/s (60 m/s)
Liquid: 23 ft/s (7 m/s)
Steam: 230 ft/s (70 m/s)
Repeatability 0.3% of reading
Output 4 to 20 mA and Pulse; Optional HART or
Modbus RS 485
Temperature Limit Standard: 302°F (150°C)
Medium: 482°F (250°C)
High: 662°F (350°C)
Power Requirements 13.5 to 42 VDC
Process Connections Wafer or ANSI Flange
Resolution/ Display LED
Pressure Limits See Flange Rating
Enclosure Ratings NEMA 4 x (IP67)
Agency Approval CE
Weight See Manual
Service Compatible Liquids
Wetted Material Sensor: Aluminum alloy or Plastic alloy
Accuracy 1%
Ranges 1200A-S2: ½" to 4", 1200A-M2: 2" to 28",
1200A-HS: ½" to 4", 1200A-HM: 2" to 28"
Repeatability 0.2%
Output 1200A-100F1: RS 485, 4 to 20mA and
frequency output
1200A-100M: RS 485, 4 to 20 mA and
frequency output
1200A-100H: RS 232
Temperature Limit 32°F to 320°F (0°C to 160°C)
Power Requirements 1200A-100F1: 85 to 264 VAC or 24 VDC,
1200A-100M: 8 to 36 VDC
1200A-100H: 90 to 230 VAC or Ni-MH battery
Process Connections ANSI 150#, 300#, 600#, 900# or AWWA Flanges
Resolution/ Display 1200A-100F1: 2” H x 20” W, 2 line x 20 characters
1200A-100M: 2” H x 20” W, 2 line x 20 characters
1200A-100H: 4” H x 16” W, 4 line x 16 characters
Pressure Limits As per flange rating
Enclosure Ratings 1200A-100F1: IP65, 1200A-100M: IP57
1200A-100H: IP65
Weight See Manual
11
Indicator Controller
A full line of digital panel meters, indicators and control instrumentation for process indication and control
Loop-Powered Indicators- Tek-Lcd 7800A Series
Display Feet & Inches display: 0.60” (0.04ft) high, 0 to 699 FT – 11 15/16 IN with 1/16 or 1/8 fraction display
Display Update Rate Ambient > -13°F: 2 Updates/Second Ambient < -13°F: 1 Update/5 Seconds
Over Range Level display flashes to 699 FT 11 15/16 IN Volume display flashes 9999999 if over range
Under Range Display flashes -999999Recalibration Recommended at least every 12 months.Normal Mode Rejection
64 dB at 50/60 Hz
Operating Temperature Range
-40 °F to 167 °F
Storage Temperature -40 °F to 167 °FRelative Humidity 0 to 90% non-condensingConnections Screw terminals accept 12 to 22 AWG wireWeight 5.00 lbs (80 oz, 2.27 kg)
10
Venturi Tubes - Tek-DP 1640A
Orifice meters - Tek-DP 1610A
Cone Flowmeter - Tek-DP 1620A
Flow nozzles - Tek-DP 1630A
Service Liquids and Gas
Wetted Material 304 SS, 316 SS, 316 SS as standard. Monel, PP, PVC, PTFE coated
Temperature Limit Standard -20 °F to 100 °F (-28 °C to 37 °C), optional -40 °F to 1200 °F (-40 °C to 648 °C)
Weight See Manual
Service Liquids and Gas
Wetted Material 304 SS, 316 SS, 316 SS as standard. Hastelloy-C, Weight See Manual
Service Liquids and Gas
Wetted Material Carbon steel for weld in type, 304 SS, 304 SS, 316 SS, 316 SS for holding ring type and Ni, Cr, Mo Alloy Steel for flanged type
Weight See Manual
Service Liquids and Gas
Wetted Material All standard materials availableWeight See Manual
12 13
Analog Input Batch Controller - TEK-BATCH 7900A
Display Upper display: 0.60" (0.04ft) high. Lower display: 0.46" (0.03ft) high. Both are 6 digits (-99999 to 999999), red LEDs.
Display Update Rate 5/second (200 ms)Over Range Display flashes 999999Under Range Display flashes -99999Recalibration Recommended at least every 12 months.Normal Mode Rejection
Greater than 60 dB at 50/60 Hz (PD8-6210)Isolation: 4 kV input/output-to-power line.500 V input-to-output or output-to-P+ supply.
Operating Temperature Range
T6 Class: -40 °F to 140 °FT6 Class: -40 °F to 65 °F
Storage Temperature -40 °F to 167 °FRelative Humidity 0 to 90% non-condensingConnections Screw terminals accept 12 to 22 AWG wireWeight 16.0 lbs (7.26 kg)
Explosion-Proof Loop-Powered Indicators- Tek-Lcd 7800B
Display Five digits (-9999 to 99999) 0.70” (0.05ft) high, 7-segment, automatic lead zero blanking
Display Update Rate Ambient > -13°F: 2 Updates/Second.Ambient < -13°F: 1 Update/5 Seconds
Over Range Display flashes 999999Under Range Display flashes -99999Recalibration Recommended at least every 12 months.Normal Mode Rejection 64 dB at 50/60 Hz
Operating Temperature Range -40 °F to 167 °F
Storage Temperature -40 °F to 167 °F
Relative Humidity 0 to 90% non-condensingConnections Screw terminals accept 12 to 22 AWG wireWeightAgency Approval
5.00 lbs (80 oz, 2.27 kg) FM, CSA, ATEX, CE
14 15
Large Display Batcher- Tek-Batch 7900B
SERIES NEMA 4X FLOW COMPUTER- TEK-FC 8000B
Operating Temperature -4 °F to 131 °F
Storage Temperature -40 °F to 185 °F Humidity 0-95% Non-condensingMaterials UL, CSA, VDE approvedKeypad Keypad Type: Membrane Keypad with 116
keys, Keypad Rating: Sealed to NEMA 4X / IP65Accuracy 0.02% FS at -4 °FRanges Voltage: 0-10 VDC, 0-5 VDC, 1-5 VDC
Current: 4-20 mA, 0-20 mA, 4-20 mA stacked, Basic Material Resolution 16 bit
Update 4 updates/sec Automatic Fault Detection Signal over/under-range, Current Loop Broken
Calibration Operator assisted learn modeExtended Calibration Learns Zero and Full Scale of each rangeReal Time Clock The Flow Computer is equipped with a non-volatile
real time clock with display of time and date.Format: 24 hour format for time Day, Month, Year for date
Operating Temperature 32 °F to 122 °F
Storage Temperature -40 °F to 185 °F Humidity 0-95% Non-condensingMaterials Plastic, UL94V-0, Flame retardant Bezel: Textured
per matt finishKeypad Keypad Type: Membrane Keypad with 16 keysAccuracy 0.02% FS at -4 °FRanges Voltage: 0-10 VDC, 0-5 VDC, 1-5 VDC
Current: 4-20 mA, 0-20 mA, 4-20 mA Basic Measurement Resolution 16 bit
Update 4 updates/sec Automatic Fault Detection Signal over/under-range, Current Loop Broken
Calibration Software Calibration (no trimmers) Extended Calibration Learns Zero and Full Scale of each range using special
test modeReal Time Clock The Tek-Batch is equipped with a battery backed
real time clock with display of time and date.Format: 12 or 24 hour time display; Day, Month, Year, date display
1716
19
Level Measurement
Tek-Trol’s level measurement devices offers the right solution for your level measuring
requirements
Explosion Proof Guided Wave Radar Transmitter - Tek-Flex 4100A
18
Accessories
Tek-Trol provides wide range of instrumentation accessories, products and configurations for
optimum efficiency and durability for all industrial applications
Manifold Valve - Tek-Manifold 7500A
Service Compatible liquids, gases, or steam
Wetted Material Body, stem, valve assembly: SS 316; Stem packing: PTFE
Temperature Limit 450°F (232°C) Pressure Limits 6000 PSI (400 bar)
Service Water/Wastewater Industry and Chemical Industry
Wetted Material 316 SS, PTFERanges up to 10’ with minimum dielectric constant of 0.3Accuracy ± 0.039” ( 0.003ft) or 0.02% of measured distance,
whichever is greatestRepeatability ±0.02” (0.001ft)Resolution 0.0008”Temperature Limit Electronics: -40 ºF to 158 ºF (-40 °C to 70 ºC)
Pressure LimitsProcess/Probe: -40 ºF to 398 ºF (-40 °C to 203 ºC)-14.50 PSI to 580 PSI
Power Requirements 24 VDC <3WOutput Signal 4 mA to 20 mAProcess Connection ¾” NPTEnclosure Rating NEMA 6Mounting Orientation Vertical Failsafe
Agency Approvals
User selectable to 3.8 mA, 4 mA, 20 mA, 20.2 mAor last signalExplosion Proof
20 21
Two Wire TDR Level Transmitter with HART - TEK-FLEX 4100C
2-Wire Loop Powered TDR Level Meter - Tek-Flex 4100B
Service Liquids
Wetted Material 316 SS, PTFE Accuracy ±0.039” ( 0.003ft) or 0.02% of measured distance,
whichever is greatest Ranges Up to 60’ Repeatability ±0.02” (0.001ft) Output 4 - 20 mATemperature Limit Electronics: -40°F to 158°F (-40°C to 70°C)
Process/Probe: -40°F to 398°F (-40°C to 203°C) Power Requirements 12 to 28 VDC (2-Wire)Process Connections ¾” NPT Resolution/ Display 5 DigitsPressure Limits -14.50 PSI to 580 PSI (-1 bar to 40 bar)Enclosure Ratings NEMA 6 Weight 2 lbs. (without probe)
Service Liquids and Bulk Solids
Wetted Material 316 SS, PTFE Accuracy ±0.4" (0.03ft)Ranges Up to 10' with minimum dielectric constant of 0.3 Repeatability ±0.02" (0.001ft) Output 4 to 20 mA/HARTTemperature Limit Electronics: -40 °F to 158 °F (-40 °C to 70 °C)
Process/Probe: -40 °F to 398 °F (-40 °C to 203 °C) Power Requirements 16 to 36 VDC (2-wire)Process Connections 1 ½" NPT Resolution/ Display 5 DigitsPressure Limits -14.50 PSI to 580 PSI (-1 bar to 40 bar)Enclosure Ratings NEMA 4XWeight 2 lbs. (without probe)
Ultrasonic Level Transmitter - Tek-Sound 4200A
Service Liquids and Bulk Solids
Wetted Material PVC Accuracy ±0.25% of max range Ranges 106” (9’), 193” (16’), 240” (20’), 358”(30’), 598”(50’),
717” (60’) Repeatability 0.08”Output 4 to 20 mA as Standard or Optional RS 232 or RS 485 or
750 Ω on 4 Wire Temperature Limit Electronic Enclosure: -40°F to 140°F (-40°C to 60°C);
Temperature Compensation: -40°F to 140°F (-40°C to 60°C)Power Requirements 4 Wire: 115 VAC at 60 Hz or 230 VAC at 50Hz
3 Wire: 12 VDC to 30 VDC Process Connections 1" NPT or 3" NPT Resolution/ Display 3 Digits Pressure Limits Up to 72 PSI (5 bar) Enclosure Ratings NEMA 6 (IP68) Weight 4.0 lb (1.8 kg)Agency Approval CE
22 23
Differential Pressure Level Transmitter - Tek-Hydro 4500A-D
Service Compatible Liquids
Wetted Material Hastelloy C, 316 SS Accuracy ±0.075% of span Ranges 1.5 in H₂O to 1450 PSI (0.0037 bar to 100 bar)Output 4 to 20 mA with HART Temperature Limit Process temperature: -40°F to 248°F (-40°C to 120°C)
Operating temperature: -40°F to 185°F (-40°C to 85°C)Power Requirements 12 to 45 VDC Process Connections Diaphragm SealResolution/ Display 6 Digit DisplayEnclosure Ratings IP67 (NEMA 4X)Agency Approval FM/FMC, KOSHA KTL, ATEX
Two Wire Ultrasonic Level Transmitter - TEK-Sound 4200B
Service Liquids
Wetted MaterialEnclosure
Transducer: PTFEPowered Coated Aluminum
Weight 2 lbs.Accuracy 0.5%Ranges 13ft to 25ftRepeatability .08”Output 4 to 20 mA/HARTTemperature Limit -40°F to 248°F (-40 °C to 70 °C) Power Requirements 16 to 36 VDC (2-Wire)Process Connections 1½" NPTResolution/ Display 5 Digit DisplayPressure Limits -0.02 to 0.1Enclosure Ratings IP67 Beam Angle 5.5° From CenterWeight 2 lbs.
Radar Level Transmitter - Tek-Wave 4300A
Service Liquids and Bulk Solids
Wetted Material Antenna: Polypropylene (PP)Enclosure AluminumAccuracy ±0.25% of max range Ranges 201” (17ft), 393” (33ft), 590” (50ft), 1197” (100ft) Repeatability 0.08”Output 4 to 20 mA HARTTemperature Limit -40°F to 140°F (-40°C to 60°C) Power Requirements 12 to 30 VDC (2 Wire)Process Connections 1½" NPT or 2" NPT Resolution/ Display No DisplayPressure Limits Up to 72 PSI (5 bar) Enclosure Ratings NEMA 6 (IP68) Weight 6 Lbs.Agency Approval FM
24 25
Hydrostatic Level Transmitters - Tek-Hydro 4500A-G
Service Compatible Liquids
Wetted Material Hastelloy C, 316 SS Accuracy ±0.075% of span Ranges 0.21 PSI to 8700 PSI (0.015 bar to 600 bar)Output 4 to 20 mA HART Temperature Limit Process temperature: -40°F to 248°F (-40°C to 120°C)
Operating temperature: -40°F to 185°F (-40°C to 85°C)Power Requirements 12 to 45 VDC Process Connections Diaphragm SealResolution/ Display LCD displayEnclosure Ratings IP67 (NEMA 4X)Agency Approval FM/FMC, KOSHA KTL, ATEX
Service Compatible Liquids
Wetted Material Body 304 SS, 316 SS Cable: PTFE or PolyurethaneAccuracy ±0.5% FSRanges 5 psig to 20 psig (3.5 mH2O to 14 mH2O),
Optional ranges availableOutput 4-20 mA, RS-485, 0.5-4.5 VDCPower Requirements 12 to 36 VDCTemperature Limit -40 °F to 257 °F (-40 °C to 125 °C)Pressure Limits 150% of spanEnclosure Ratings IP68Weight 0.9 lbs (408 g)
Submersible Level Transmitter - Tek-Sub 4800B
PTFE Submersible Level Transmitter - Tek-Sub 4800A
Service Compatible Liquids
Wetted Material Body: PTFE, O-Ring: FKM fluorine rubber Diaphragm: Ceramic (Al₂O₃, 96%)Cable: PTFE or Polyurethane
Accuracy ±0.5% FS Ranges 2.8 psig to 15 psig (2 mH2O to 10.5 mH2O)
Optional ranges availablePressure Limits 150% of spanOutput 4 to 20 mA RS 485 or 0.5 to 4.5 VDC Temperature Limit -20°F to 160°F (-29°C to 71°C) Pressure Limits 150% of spanEnclosure Ratings IP68Weight 0.9 lb (415 g)
26
Wastewater Submersible Level Transmitter - Tek-Sub 4800D
Service Compatible Liquids
Wetted Material 304 SS, 316 SSAccuracy 0.25% FSRanges 10 psig to 50 psig (7 mH2O to 35 mH2O),
Optional ranges availableOutput 4-20 mA, RS-485, 0.5-4.5 VDC Temperature Limit -40 °F to 257 °F (-40 °C to 125 °C)Power Requirements 12 to 36 VDCPressure Limits 150% of SpanEnclosure Ratings IP68Weight 0.49 lb (225 g)
Service Compatible Liquids
Wetted Material 304 SSAccuracy ±0.5% FSRanges 5 psig to 20 psig (3.5 mH₂O to 14 mH₂O),
Optional ranges availableOutput 4-20 mA, RS-485, 0.5-4.5 VDCTemperature Limit -40 °F to 257 °F (-40 °C to 125 °C)Power Requirements 12 to 36 VDC Pressure Limits 150% of SpanEnclosure Ratings IP68Weight 8.8 lb (4000g)
0.062 ft Submersible Level Transmitter- Tek-Sub 4800C
27
Validation System
Diagnostic systems that provide real-time validation and monitoring
TekValSys DP
• Reduced Financial Exposure to Mismeasurement• Reduced Maintenance Cost• Reduced Risk to Personnel Health and Safety• Assurance of Meter System Performance• Possibility of Achieving Financial Payback in Few Days
This patented technique has proven to be an extremely powerful tool in ensuring accuracy, providing real-time alerts of meter mismeasurement, and performance shifts, and reducing maintenance overheads on DP systems. Applicable to all types of differential pressure metering systems, including Orifice, Venturi, Cone, Flow Nozzle, and Wedge; TekValSys DP uses 3 Differential Pressure (DP) measurements to monitor the entire pressure field through the meter body.
28 29
TekValSys GC
• Provides real time assurance that the GC is operating correctly• Analyzes historical data to identify changes and predict future failures• Reduces the need for conventional maintenance and unnecessary costs• Determines dynamic GC uncertainty for quantification of GC performance• Validates that the pressure let down system provides a representative sample• Creates a fully auditable database of GC performance• Helps to support and increase a technician's competence level
A unique and comprehensive Condition-Based validation software package for Gas Chromatographs (GCs), comprising GCAS software and Panel PC for hazardous or safe areas.As an automated, condition-based monitoring software, TekValSys GC:
3130
Temperature Measurement
Tek-Trol’s Temperature measurement devices provides accurate measurement of temperature even in the most
challenging conditions
Explosion-Proof Temperature Transmitter - Tek-Temp 2100A
Service Liquids and Gases
Wetted Material See Model ChartWeight 2.4 lb (1.2 kg) Accuracy ±0.003% of span Ranges As per sensor, refer the catalog for details Repeatability ±0.1% typicalOutput 4 to 20 mATemperature Limit Without condensing: -40°F to 185°F (-40°C to 85°C)
With LCD module: -22°F to 176°F (-30°C to 80°C) Power Requirements 10 to 45 VDCProcess Connections See Model Chart Resolution/ Display Optional 5 digit LCD displayEnclosure Ratings FM for Class I, Division 1Agency Approval CE, FM
Pressure Measurement
Our high-quality pressure measuring devices provides stable, reliable and accurate measurements
inprocess industries that requires high-precision measurement solutions
Explosion-Proof Differential Pressure Transmitter - Tek-Bar 3110A
Service Compatible gases, steam, liquids Wetted Materials 316 SSAccuracy 0.075% of URL Range Ability 100:1 Turn DownStability ±0.2% URL/5 yrTemperature Limits Process: -40°F to 185°F (-40°C to 85°C) Pressure Ranges 5.8 PSIG to 5800 PSIG (0.4 bar to 400 bar) Power Requirements 10.5 to 55 VDCOutput Signal 4 to 20 mA / HARTLoop Resistance Operation: 0 to 2119 Ω; HART Communication: 250 Ω Electrical Connection ½" female NPT conduit Process Connection ¼" female NPT Display Optional 5 digit LCD Weight 8.8 lb (4.0 kg) Enclosure Rating NEMA 4 x (IP66)Agency Approval CE, FM (ClassⅠ, DivⅠ )
32 33
Smart Gauge Pressure Transmitter - Tek-Bar 3120B
Service Compatible gases, steam, liquids Wetted Materials Hastelloy C, 316 SSAccuracy 0.075% of URL Range Ability 40:1 Turn DownStability ±0.2% URL/5 yrTemperature Limits Process: -40°F to 185°F (-40°C to 85°C) Pressure Ranges 5.8 PSIG to 5800 PSIG (0.4 bar to 400 bar) Power Requirements 10.5 to 55 VDCOutput Signal 4 to 20 mA / HARTLoop Resistance Operation: 0 to 2119 Ω; HART Communication: 250 Ω Electrical Connection ½" female NPT conduit Process Connection ½" male NPT Display Optional 5 digit LCD Weight 3.43 lb (1.56 kg) Enclosure Rating NEMA 4 x (IP66)
Tri-Clamp Gauge Pressure Transmitter - Tek-Bar 3120C
Service Compatible gases, steam, liquids Wetted Materials 316 SSAccuracy ±0.2% F.S.Range Ability 40:1 Turn DownStability ±0.2% URL/5 yearsTemperature Limits -40°F to 185°F (-40°C to 85°C) Pressure Ranges 5.8 PSIG to 300 PSIG (0.4 bar to 20.6 bar)Power Requirements 10.5 to 55 VDCOutput Signal Two wire, 4- 20 mA with HARTLoop Resistance Operation: 0 to 2119 Ω; HART Communication: 250 ΩElectrical Connection ½” female NPT conduitProcess Connection 1-½” Tri-Clamp or 2” Tri-Clamp Display 5 digit LCD Weight 3.43 lb (1.56 kg) Enclosure Rating NEMA 4 x (IP66)
18 23
Smart Differential Pressure Transmitter - Tek-Bar 3110B
Service Compatible gases, steam, liquids Wetted Materials Hastelloy C, 316 SSAccuracy 0.075% of URL Range Ability 100:1 Turn DownStability ±0.2% URL/5 yrTemperature Limits Process: -40°F to 185°F (-40°C to 85°C) Pressure Ranges 5.8 PSID to 5800 PSID (0.4 bar to 100 bar) Power Requirements 10.5 to 55 VDCOutput Signal 4 to 20 mA / HARTLoop Resistance Operation: 0 to 2119 Ω; HART Communication: 250 Ω Electrical Connection ½" female NPT conduit Process Connection ¼" female NPT Display Optional 5 digit LCD Weight 8.8 lb (4.0 kg) Enclosure Rating NEMA 4 x (IP66)
Explosion-Proof Gauge Pressure Transmitter - Tek-Bar 3120A
34 35
Service Compatible gases, steam, liquids Wetted Materials 316 SSAccuracy 0.075% of URL Range Ability 100:1 Turn DownStability ±0.2% URL/5 yrTemperature Limits Process: -40°F to 185°F (-40°C to 85°C) Pressure Ranges 5.8 PSIG to 5800 PSIG (0.4 bar to 400 bar) Power Requirements 10.5 to 55 VDCOutput Signal 4 to 20 mA / HARTLoop Resistance Operation: 0 to 2119 Ω; HART Communication: 250 Ω Electrical Connection ½" female NPT conduit Process Connection ½" male NPT Display Optional 5 digit LCD Weight 3.43 lb (1.56 kg) Enclosure Rating NEMA 4 x (IP66)Agency Approval CE, FM (ClassⅠ, DivⅠ )