the u. s. department of energy’s mixed-analyte performance evaluation program (mapep) fy 2014...

Post on 02-Jan-2016

216 Views

Category:

Documents

1 Downloads

Preview:

Click to see full reader

TRANSCRIPT

The U. S. Department of Energy’s Mixed-Analyte Performance Evaluation Program (MAPEP)

FY 2014 Review

Shane SteidleyDOE Radiological and Environmental

Sciences Laboratory ASP Meeting 2014

Sept. 18, 2014

2

MAPEP Participant Policy

Participating Laboratories

Inorganic Uncertainties

Strontium 89/90 Air Filter

Certified Reference Materials Update

MAPEP Series 29-30 Overview

3

MAPEP Participant Policy

Agree to abide by MAPEP’s System or Export Control Agreement

Labs notified if:

· MAPEP standards are returned to RESL

· Results are not reported in two Series

Non-responding labs will be deactivated

4

MAPEP System Usage Agreement

5

Export Control Agreement

Export Control Agreement = System Usage Agreement

6

Sys Usage Agrmnt

7

MAPEP Test SessionSeries

29Series

30

Dates ShippedAugust 2013

March 2014

Laboratories Participating 124 128 Domestic 92 90

International 32  38Proficiency Testing Standards

Shipped 653 644

MAPEP Series 29 & 30 by the Numbers

8

Analytical results are not absolute

Uncertainty establishes the range around the result where the true value is expected

Inorganic False Positive and Sensitivity Tests

Inorganic Uncertainty Reporting

9

No Uncertainty Reported

10

Must Report Numeric Results

11

MAPEP Series 30 False Positives

Cs-

13

4

Ni-6

3

Sr-

90

Fe

-55

K-4

0

Zn

-65

Be

rylli

um

Th

alli

um

Co

-57

Zn

-65

MaS30 MaW30 MaW30 RdF30

0

20

40

60

Not Acceptable

Acceptable

Re

po

rtin

g L

ab

ora

tori

es

12

MAPEP Series 30 Sensitivity Evaluations

Co-60 Nickel Pu-238MaS30 MaW30 RdF30

0

10

20

30

40

50

60

70

Not Acceptable

Acceptable

Re

po

rtin

g L

ab

ora

tori

es

13

New MAPEP Uncertainty Flags

Relative Precision (RP) Flag

RP < 2% N

2 < RP < 15% A

15 < RP < 30% W

RP > 30% N

■ Uncertainty flags are for information only

■ Series 30

●~ 82% Uncertainties = A

●~ 10% Uncertainties = N or <2% or >30%

14

“Can I just report my MDL?”

· Report the calculated result and total uncertainty

“Can I report a less than value?”

· No, non-numeric results are not allowed

“What if I’m contractually obligated to use a specific procedure?”

· The laboratory is responsible to ensure the procedure they use produces accurate results

Frequently Asked Questions

15

Uranium Isotope Results Reported By Alpha & Gamma Spec

U-234

U-238

U-234

U-238

U-234

U-238

U-234

U-238

U-234

U-238

U-234

U-238

MaS25 MaS26 MaS27 MaS28 MaS29 MaS30

0

10

20

30

40

50

Not AcceptableWarningAcceptable

Rep

ortin

g La

bora

torie

s

--Natural-- ------------- Depleted ----------------- ------- Natural-------

16

MAPEP-14-MaS30Radiological Uranium-238

Not Acceptable Acceptable

Acceptable Results =>

Total Dissolution

Gamma Spectrometry

10 out of 45 Laboratories Reported “Acceptable “ Results

17

Performance Evaluation of Sr-89/90 in Series 31 Air filter

Many requests for performance testing of fresh fission products· Renewed interest since Fukushima· Sr89/90, I-131, Zr-95/Nb-95, etc.

Twenty-three laboratories request the Sr-89/90 Air Filter· 12 requested Sr-89 out of 32 who routinely analyze Sr-90· 11 who don’t report Sr-90, requested SrF31

Do all 32 labs have analytical capability in Sr-89?

Is there a continued interest in Sr-89/90 or other fresh fission products determinations?

18

RESL’s CRM Update

19

MAPEP PT Standards available as CRMs

20

Certificate of Traceability

21

RESL Food CRMs

22

RESL CRMs

23

Rad Decay Report

24

http://www.inl.gov/resl/mapep

· Public access

· Statistical summary

http://mapep.inl.gov

· Requires account /password

· Used for reporting/reviewing data

· Various search utilities, historical performance reviews, graphs, individual laboratory reports, sample descriptions, program information

MAPEP Websites

25

http://www.inl.gov/resl/mapep

Send completed forms to MAPEP@ID.DOE.GOV

Any questions contact MAPEP coordinator

Guy Marlette (208-526-2532), marletgm@id.doe.gov

MAPEP Application

26

RESL Contacts

Anita Bhatt, RESL Director – bhattar@id.doe.gov

Shane Steidley, MAPEP Database – steidlsd@id.doe.gov

Temple Warwick, Radiochemist – warwicpc@id.doe.gov

Guy Marlette, MAPEP Coordinator – marletgm@id.doe.gov

Thank You for Your Time

top related