RAILROAD COMMISSION OF TEXAS
UIC Completion Reporting Guidance
Jim Moore, Engineering Specialist IIInjection-Storage Permits & Support
2
PRESENTATION OVERVIEW
A few examples of RRC webpage research including UIC webpages then a step-by-step guidance for W-2/G-1 online completions for injection / disposal / storage / brine mining wells. Steps include log in, starting or updating a completion packet, entering data, additional forms, submitting, messaging, and problem resolution.
Please ask questions during the presentation.
3
RRC HOMEPAGE
Data – Online Research Queries
Oil & Gas link or pull-down menu
RRC Online Log In
4
RRC WEBPAGE
Oil & Gas Completion Query
Online Research Queries
Injection/Disposal Permit Query
Oil & Gas Imaged Records Menu
5
RRC WEBPAGE
Oil & Gas Well RecordsGAU LettersDisposal Permits (W-14)Injection/Disposal Permits (H-1/H-1A)
Oil and Gas Imaged Records Query Menu
These are links to Neubus
6
OVERVIEW INJECTION PERMIT TYPES
• H-1/H-1A – Enhanced Recovery– Oil and Gas Waste Disposal
• W-14– Oil and Gas Waste Disposal
• H-2– Brine Mining
• H-4– Underground Hydrocarbon Storage
7
INJECTION/DISPOSAL PERMIT DETAIL
• Base of Usable Quality Water• Casing Record• Injection Interval• Tubing/Packer Depth• Formation Name(s)• Permit Special Conditions
8
IMPORTANT PERMIT DATA
• Field Name & Field Number– Matches on Completion (Form W-2/G-1), Drilling Permit (Form W-1)
• Well Number– Can be changed/updated with Completion
Injection Disposal
Well
Drilling Permit
UIC Permit
Completion Report
9
COMPLETION OVERVIEW
• Packet Data• Form W-2/G-1 Data• Complete Additional Forms– P-4, W-12, L-1
• Load Attachments– W-15, W-12, GAU Letter (formerly TCEQ ),
Log Header, others e.g. SWR13 Exception Letter• Submit
10
ONLINE SYSTEM
Select Completions
11
FILING OPTIONS & MESSAGES
File a New Completion or Update Existing Completion Packet
Check Messages for your User ID, orfind all Messages for this Operator
12
UPDATE EXISTING PACKET
Packet Status:- Submitted
Packet Status:- Work In Progress- Pending Operator Update- Hard Copy
View By options
13
FILE A NEW COMPLETION PACKET
Click Search
EnterDrilling Permit No. orAPI No.
14
Multiple Field Names Allowed on Drilling Permit New Packet
FILE A NEW COMPLETION PACKET
15
o Multiple Drilling Permits may be populated when searching with APIo Drilling Permit’s can have multiple field nameso Choosing the Correct Drilling Permit is very Important!
CHOOSE THE CORRECT DRILLING PERMIT
16
PACKET DATA
Purpose of FilingType of CompletionWell TypeWellbore ProfilePacket Type
Definitions for Purpose of Filing
Recommended sequence
17
PACKET DATA
18
PACKET DATA
19
PACKET DATA
(For WSW, Water Supply Wells)
20
PACKET DATA
Wellbore Profile is auto-populated from Drilling Permit, Form W-1
21
PACKET DATA
22
PACKET DATA
Click Create Packet tab
Tracking Number gets assigned
Purpose of FilingType of CompletionWell TypeVertical ProfilePacket Type
Done1
2
3
23
PACKET DATA
Fill in Well Data
Recompletion/Reclass Table
Save
Change Packet Description
24
PACKET DATA
New data fields 01/2014
Enter Permit No. & Date
Prior Service TypeSearch for Field & Reservoir
25
PACKET DATA
Search for Field & Reservoir
1 result
Select
26
W-2/G-1 PAGE 1
Page 1: Potential Test Data
Save, Select Page #
Select W-2 to continue
27
W-2/G-1 PAGE 2
Save
Fill In Well Data
System responds with red text warnings if critical data is missing on this page.
28
W-2/G-1 PAGE 3
New data fields 01/2014
29
W-2/G-1 PAGE 4
New data fields 01/2014
Type of Casing (pull-down)ConductorSurfaceIntermediateConventional ProductionTapered ProductionOther
Top of Cement Determined By (pull-down) CalculationTemperature SurveyCement Evaluation LogCirculated
30
W-2/G-1 PAGE 4
Active UIC:Tubing & Packer SetPossible exceptions- Brine mining- Hydrocarbon storage- Permit exception
31
Perforations and Packer Depth
Permitted Interval
Needs to be less than 100’ unless permitted packer depth allows it
Injection Interval
o Insure Packer, Perforations and Plug Back depth all agree
32
Example Permit
o Permitted Interval: 5577-6468’
o Actual Packer depth: 5800’
33
Example of Inaccurate Reporting
5577
6468
5800Actual
Perforations:6000-6150
o If the permitted interval is reported instead of the completed interval, there is an obvious discrepancy
34
W-2/G-1 PAGE 5
This table is required for Well Type: Active UIC
Can be “Yes” for Shut-In UIC
Injection/Disposal Interval is within Permitted Interval
35
W-2/G-1 PAGE 5
Process (pull-down)AcidFractureCement SqueezeCast Iron Bridge Plug*RetainerOther
New data fields 01/2014
List all Work Chronologically, attach Form W-15 for new CIBP, Cement Squeeze, Squeeze Perfs, etc.
36
W-2/G-1 PAGE 5
When to mark “Encountered”, “Isolated”
New data fields 01/2014
37
RRC WEBPAGE
Revised SWR 13 – Casing, Cementing, Drilling, Well Control, and Completion Requirements
Oil & Gas page
Compliance & Enforcement
Quick recommendation!!
38
RRC WEBPAGE
Rule 13 – Geologic Formation Information
Compliance & Enforcement page
39
EXAMPLE FORMATION TOPS
40
W-2/G-1 PAGE 6
Certify (or Re-certify)
Electronic Signature
Red text warnings if critical data is missing on W-2/G-1.
41
COMPLETE ADDITIONAL FORMS
Additional Forms
Attachments
Select P-4 Certificate of Compliance and Transportation Authority
Determine All Required Forms
42
ADDITIONAL FORM: P-4
Service Well, Yes
Certify (or Re-certify)
Gatherers and/or Purchasers info left blank.*
RRC Gas ID or Oil Lease No. is blank/zero
43
ADDITIONAL FORM: P-4
Certify (or Re-certify)
Electronic Signature
44
ADDITIONAL FORM: W-12
Well Information
Shot Point Information
Certify (or Re-certify)Electronic Signature
45
ADDITIONAL FORM: L-1
Certify (or Re-certify)Electronic Signature
Basic Electric Log Run
Option: ConfidentialityAttach Log Header
Option: Log AttachedMail Log to RRC AustinAttention: Proration or UIC
46
LOAD ATTACHMENTS
Additional Forms
Attachments
Select W-15 Cementing Report
Determine All Required Forms
47
LOAD ATTACHMENTS: W-15
Current Attachments
Browse to file location such as your Desktop
Upload
21 3
Formats: .pdf or .tif
48
RRC WEBPAGE
Forms- Proposed Form Changes
Oil & Gas page
Quick recommendation!!
49
RRC WEBPAGE
W-15 Cementing Report
Proposed Form Changes
50
LOAD ATTACHMENTS: W-12
Current Attachments
Pick 1 of 2 ways to initiate the Upload Attachment step
51
LOAD ATTACHMENTS: W-12
Select W-12
Pull-Down/Pull-Up Menu for Attachment Type
52
COMPLETION OVERVIEW
• Packet Data• Form W-2/G-1 Data• Complete Additional Forms– P-4, W-12, L-1
• Load Attachments– W-15, W-12, GAU Letter (formerly TCEQ ),
Log Header, others e.g. SWR13 Exception Letter• Submit
53
SUBMIT PACKET
Form Name
Attachments
Submit
Service Well, Yes
54
SUBMIT PACKET
Submit
NoNo
55
SUBMIT FORMS LACKING
• Submit with required forms missing or uncertified?: • Submit with required attachments missing?:
Answer 1 or both “Yes”
If RRC analysts give Final Approval to the Completion Packet with Forms Lacking, then the Operator will need to provide the missing forms or attachments as soon as possible. Warning letter will follow.
56
SUBMIT PACKET
… submitted successfully message
57
PROBLEM RESOLUTION
• Respond to RRC messages on packet• Provide additional data, forms, attachments• Electronic signature & re-certify all forms released• Re-submit packet if released• Problem resolution
– W-1 Drilling Permit Amendment– H-1/H-1A or W-14 Injection/Disposal Permit Amendment– UIC Certified Letter– UIC Severance Letter– Refer to SWR 16
58
REQUIREMENTS
• W-1 Drilling Permit – refer to SWR 5 (512) 463-6751– New Well– Deepening– Re-enter– Plug Back / Re-Completion in a Different Field
• W-15 Cementing Report – check with RRC Districts– New Well– Cement (CS)/ Block Squeeze (CS), Squeeze Perfs, Bridge Plug (CIBP),
Plug Back– May relate to Injection/Disposal Permit Special Conditions
59
REQUIREMENTS
• W-12 Inclination Report – refer to SWR 11– New Well, Total Depth > 2000 feet– Re-Enter requires new survey if one was not already filed
• exception for Enhanced Recovery– Deepening
• Directional Survey– New Drill if the Wellbore Profile is Directional or Horizontal– New Drill if the Wellbore Profile is Vertical
• and the W-12 violates 11(c)(1)(A)– Applicable to some Re-Entry, or Deepening– Directional Surveys filed/uploaded by the responsible service company– RRC Engineering Unit & Support (512) 463-1126
60
TERMS & DEFINITIONS
• UIC : Underground Injection Control • UIC Number : 9 digit number assigned to Well• H-1 Number : Project number– Fluid Injection Permit No. (label on Packet Data)– F- followed by 5 digits
• W-14 Number : Permit number– O&G Waste Disposal Permit No. (label on Packet Data)– 5 digits
61
TERMS & DEFINITIONS
• API Number : 10-digit number assigned to Well• Well Number : D or L D D D L L , D=digit L=letter• RRC District No.• RRC Oil Lease No. : 5 digit Number • RRC Gas ID : 6 digit Number• Plat : Lease Map, Survey Location
62
TERMS & DEFINITIONS
• H-1 Field Name– correlative to injection/disposal Formation(s)– use deepest if more than one Formation– well is on current schedule in one of the proposed
Formations, then keep current Field Name• W-14 Field Name– correlative to disposal Formation(s) more than
2 miles away– or to Formation that is source of disposal fluids
63
QUESTIONS
64
CONTACT INFORMATION
• Jim Moore– Injection / Disposal Permitting– UIC Completions
• 512-463-6443 (Direct)• 512-463-6792 (Main)• 512-463-6780 (Fax)• Jim.Moore@rrc.state.tx.us