ams ts66 casement window system -...

33
AMS TS66 CASEMENT WINDOW SYSTEM - SPECIFICATION AMS Ltd. Wallingstown, Little Island, Co. Cork: Tel: 021 4705100 Fax: 021 4705198, E-mail: [email protected], Web: www.ams.ie 2.4.01 J: Profile listing, frames / sashes. 2.4.02 E: Profile listing, transoms/mullions. 2.4.03 K: Profile listing, couplers / adapters. 2.4.04 H: Accessories. 2.4.05 F: Accessories. 2.4.06 H: Sash limitations. 2.4.07 F: Glazing options, TS6202, 011. 2.4.08 D: Glazing options, TS6900. 2.4.09 E: Glazing options, TS6 915. 2.4.10 G: Glazing options, TS6 913, 923, 911 2.4.11 F: Drainage treatment. 2.4.12 E: Drainage treatment. 2.4.13 B: Sash reverser / rebate reverser options. 2.4.14 D: TS6900 - No longer available. 2.4.15 E: Assembly, TS6202, 915. 2.4.16 D: Assembly, TS6202, HL 963. 2.4.17 E: Assembly, TS6202, 913. 2.4.18 F: Assembly, TS6202, 911. 2.4.19 E: Assembly, TS6202, 913 with TBS161. 2.4.20 D: Assembly, TS6202, 913 with TBS151. 2.4.21 F: TS6911 with all around locking. 2.4.22 C: Transom options and adapters. 2.4.23 C: Detail into brick / blockwork. 2.4.24 F: Coupler/Add on/Bay details. 2.4.25 F: Butt hinge options. 2.4.26 D: Curtain wall inserts. 2.4.27 : Assembly, XT6200, TS6913. 2.4.28 : Fixing lug setout brick / blockwork. 2.4.29 C : Glazing, glass packer setout. 2.4.30 : Assembly, TS6202, 923 2.4.31 A : XT cills with riser and end plates 2.4.32 B : XT cills with riser and end plates plus drip

Upload: phamminh

Post on 02-Apr-2018

224 views

Category:

Documents


1 download

TRANSCRIPT

AMS TS66 CASEMENT WINDOW SYSTEM - SPECIFICATION

AMS Ltd. Wallingstown, Little Island, Co. Cork: Tel: 021 4705100 Fax: 021 4705198, E-mail: [email protected], Web: www.ams.ie

2.4.01 J: Profile listing, frames / sashes.

2.4.02 E: Profile listing, transoms/mullions.

2.4.03 K: Profile listing, couplers / adapters.

2.4.04 H: Accessories.

2.4.05 F: Accessories.

2.4.06 H: Sash limitations.

2.4.07 F: Glazing options, TS6202, 011.

2.4.08 D: Glazing options, TS6900.

2.4.09 E: Glazing options, TS6 915.

2.4.10 G: Glazing options, TS6 913, 923, 911

2.4.11 F: Drainage treatment.

2.4.12 E: Drainage treatment.

2.4.13 B: Sash reverser / rebate reverser options.

2.4.14 D: TS6900 - No longer available.

2.4.15 E: Assembly, TS6202, 915.

2.4.16 D: Assembly, TS6202, HL 963.

2.4.17 E: Assembly, TS6202, 913.

2.4.18 F: Assembly, TS6202, 911.

2.4.19 E: Assembly, TS6202, 913 with TBS161.

2.4.20 D: Assembly, TS6202, 913 with TBS151.

2.4.21 F: TS6911 with all around locking.

2.4.22 C: Transom options and adapters.

2.4.23 C: Detail into brick / blockwork.

2.4.24 F: Coupler/Add on/Bay details.

2.4.25 F: Butt hinge options.

2.4.26 D: Curtain wall inserts.

2.4.27 : Assembly, XT6200, TS6913.

2.4.28 : Fixing lug setout brick / blockwork.

2.4.29 C : Glazing, glass packer setout.

2.4.30 : Assembly, TS6202, 923

2.4.31 A : XT cills with riser and end plates

2.4.32 B : XT cills with riser and end plates plus drip

Page : 2.4.01

TS 66 ENERGY CASEMENT WINDOW SYSTEMProfile ListingScale NTS

Revision : J (--/--/--)

Ixx = 36.34 cm4Iyy = 14.96 cm4

Ixx = 28.53 cm4Iyy = 7.39 cm4

Ixx = 30.76 cm4Iyy = 10.24 cm4

Ixx = 43.81 cm4Iyy = 15.37 cm4

Ixx = 30.76 cm4Iyy = 10.24 cm4

HL 211Slim line insert for 28mm glazing

51

31

28

Ixx = 27.07Iyy = 12.04

Ixx = 26.13Iyy = 12.04

28

28

TS6 202FRAME

TS6 011FRAME

TS6 209INSERT FOR 28mm GLAZING

4060

53

73

31

51

28

TS6 210INSERT FOR 28mm GLAZING(Tilt and turn)

HL 963SLIM TEE SASH

28

52 12

TS6 913SASH

TS6 923SASH

TS6 915SASH

72 32

72

48

32

48

20

Ixx = 37.0 cm4Iyy = 21.6 cm4

TS6 912HEAVY DUTY SASH

87

66

Revision : E (--/--/--)Page : 2.4.02

TS 66 ENERGY CASEMENT WINDOW SYSTEMProfile ListingScale NTS

Ixx = 32.42 cm4Iyy = 11.25 cm4

Ixx = 30.63cm4Iyy = 11.25 cm4

Ixx = 93.8 cm4Iyy = 14.98 cm4

Ixx = 129.98 cm4Iyy = 17.86 cm4

Ixx = 238.56 cm4Iyy = 17.37 cm4

TS6 302MULLION / TRANSOM

7636

TS6 315MULLION / TRANSOM

36 28 76

TS6 316MULLION / TRANSOM

TS6 319REVERSER MULLION

TS6 321'Z' TRANSOM

7628

100

36

76 3656

56

50

MULLION / TRANSOMTS6 318

150

Ixx = 632.15 cm4Iyy = 60.41 cm4

36 55

76

Ixx = 164.44 cm4Iyy = 12.55 cm4

FIN MULLIONTS6 375

75

36

66

50mm FIN MULLIONTS6 375-50

Ixx = 339.14 cm4Iyy = 16.28 cm4

24

24

28

75

36

191

141

15

15

36

TS6 314MULLION - TRANSOM

Ixx = 200.18cm4Iyy = 18.00 cm4 TS 319

Ixx = 56.17cm4Iyy = 11.39 cm4 TS302 E

40

876

66

40

8

36

TS6 313MULLION - TRANSOM

TS 314

TS 314

TS 66 ENERGY CASEMENT WINDOW SYSTEMProfile ListingScale NTS

Page : 2.4.03Revision : K (--/--/--)

TS4 230TS CILL

185

80mm EXTENDERTS6 080

HL 56128mm BEAD

TBM DRIPDRIP

HL 50640mm BEAD

HL 50244mm BEAD

HL 50148mm BEAD

80

50mm EXTENDERTS6 085

50

TS6 350IN LINE COUPLER

TS6 352100mm COUPLER

TS6 35150mm COUPLER

100

50

59

90 DEGREE CORNER POSTTB6 802

30

Ixx = 248.9 cm4Iyy = 30.89 cm4

Ixx = 69.63 cm4Iyy = 3.98 cm4

Ixx = 13.85 cm4Iyy = 0.70 cm4

TBS 161REBATE REVERSER

36

HL 562Rebate reverserbead (28mmonly)

HL 563Bead - Slim linetee sash (28mmonly)

TBS 151SASH REVERSER

45

25

HL 56535mm BEAD

TS6 353100mm slim COUPLERIxx = 185.65 cm4Iyy = 7.38 cm4

100

28 28

50 28

140mm EXTENDERTS6 084

For more cill optionsrefer to 2.4.31 & 32

XT6260Cill riser profile

28

XT602828mm add on

140

28

TS6 600TS DRAIN TRAY

CILL200 - 200mm cillCILL170 - 170mm cillCILL145 - 145mm cillCILL120 - 120mm cillCILL100 - 100mm cillCILL60 - 60mm cillCILL30 - 30mm cillCILLE60 - Cill extender

CILLE230D - End cap with drip for 230mm cillCILLE170D - End cap with drip for 170mm cillCILLE145D - End cap with drip for 145mm cillCILLE120D - End cap with drip for 120mm cillCILLE100D - End cap with drip for 100mm cillCILLE060D - End cap with drip for 60mm cillCILLE030D - End cap with drip for 30mm cill

CILLE230S - End cap for 230mm cillCILLE200S - End cap for 200mm cillCILLE170S - End cap for 170mm cillCILLE145S - End cap for 145mm cillCILLE120S - End cap for 120mm cillCILLE100S - End cap for 100mm cillCILLE060S - End cap for 60mm cillCILLE030S - End cap for 30mm cill

XT6 800Bay Pole

XT6 810Bay Pole filletXT6 811

Fillet packer

TS 66 ENERGY CASEMENT WINDOW SYSTEMAccessoriesScale NTS

Page : 2.4.04Revision : H (--/--/--)

HB008 Titon left hand White

Espag locks - TS6 915, TS6 913 & TS6 923

Drain cap:DHCB - BrownDHCB1 - BlackDHCG - OakDHCS - GreyDHCW - White

HD22 - 22" hinge (Self balancing)

HD28 - 28" hingeHD26 - 26" hinge

HD10 - 10" hingestack height hingeHeavy duty 17mm

HD16 - 16" hinge

HD102x - 10" restrictorHD102 - 6" restrictorHeavy duty restrictor

TSWHM - TS Butt hinge - Mill finishTSWHS - TS Butt hinge - silverTSWHB - TS Butt hinge - Black

Butt Hinge - TS6 915

AWH019AWH020

wedge7mm locking

WhiteBlack

DescriptionTiton right hand

Titon left handTiton right hand

Titon right hand

Titon left hand

Titon cockspur handle

HB001

HB006HB005

HB007

HB002

CodeSilver

Black

SilverBlack

White

Colour

gasket

8468Wedge Wedge

3813

gasket gasketWedge CARRA

gasketbead 8467 3821

Seal8470Transomseal gasket

TSCS2Cavity separator(For energy ratedwindows)

3821 VCTVulcanised corner forexternal sash seal

3821 VCVulcanised corner forinternal sash seal

EN1150 - 1150mm espag (22mm backset)EN 950 - 950mm espag (22mm backset)EN 750 - 950mm espag (22mm backset)EN 550 - 950mm espag (22mm backset)EN 350 - 950mm espag (22mm backset)EN 280 - 950mm espag (22mm backset)

Crest butt hinge - 100mmTSHB - BLACKTSHW - WHITETSHN - SILVERTSHM - MILL FINISH

HDHPHinge protector

4500Seal

Espag locks - TS6 915, TS6 913 & TS6 923

EDA1150 - 1150mm espag (22mm backset)EDA 950 - 950mm espag (22mm backset)EDA 750 - 750mm espag (22mm backset)

Offset - disabled access handle

250

Code Description ColourEHWL Prolinea left hand WhiteEHWR Prolinea Right hand WhiteEHBL Prolinea left hand BlackEHBR Prolinea Right hand BlackEHGL Prolinea left hand GoldEHGR Prolinea Right hand GoldEHSL Prolinea left hand SilverEHSR Prolinea Right hand SilverEHCL Prolinea left hand ChromeEHCR Prolinea Right hand ChromeEHWKP Prolinea left hand Key plugEHWKP Prolinea Right hand Key plug

Prolinea espag handle with 15mm spindle

Handle specification for TS6 913,TS6 923, TS6 915 & TS6 911

Heavy duty 'Egress Hinge'HD12E - 12" HD side hung hingeHD16E - 16" HD side hung hinge

MILA releasable restrictor:AWRAR - R/H releasable

restrictor armAWRAL - L/H releasable

restrictor armAWRAS - Fixing stud for

restrictor arm

Cosmofin applicatorCF020 Manual applicatorCF021 Pneumatic applicator

TS66 Frame fixing lug

End cap for TS4 230(TSA 030 - Standard)(TSA 031 - with drip piece)

AccessoriesScale NTS

TS 66 ENERGY CASEMENT WINDOW SYSTEM

TS6 FL

Revision : F (--/--/--)Page : 2.4.05

Chevron

mixing tubeCF030

Cosmofin

CF010two part adhesiveCosmofin 900g

520109R DripFixing stud

TBM drip fixing rivetTBM drip 2

TB KEEP 2Security Keep

TBA 002

AWA002

wedging toolGlass packer and

Lug and air sealing adapterTS6FA - Full length adapter - 6.5m

Bead clipBCLIP 66

Run up blockTSA 010

Interlocking wedgeLWBK - BlackLWW - White

Transom Cruciform JigT6C1

TJM3Transom jig - double striptransom - TS6 302, TS6 315,TS6 316

Mullion / Transom bracket Doublestrip sections - TS6 302LH = TS6C3LRH = TS6C3R

Dummy sash clip for HL 963DSC1

TS6KTS66 keep

TS6KPKeep location packer

TS6FAC - Cut length for fixing lug - 70mm

BCLIPABead retaining clip

240

Page : 2.4.06

Sash LimitationsTS 66 ENERGY CASEMENT WINDOW SYSTEM

Revision : H (--/--/--)

GUIDE BLOCKS:Guide block to be fitted to each jamb on all tophung sashes and on bottom of all side hungsashes.Guide block to be positioned 100mm approx.from edge of sash. Position of guide blockshould not interfere with operation of hinge.

BUTT HINGES:Top hung sashes with butt hinges should not be hung from transomsections, should this occur contact AMS technical dept. for advice.

Top hung:Maximum sizes width = 1.5m (913 / 915) 1.65m (912), maximum height 1.4m.Sashes from 1.0m to 1.65m to have 3 No. fittings minimum. When utilisingcockspur handles, sashes over 1.4m high to have handles fitted to thejambs, contact AMS technical for advice on handle location.

Side hung:• Maximum sizes width = 0.7m, maximum height 1.65m.• Sashes from 1.0m to 1.65m high to have 3 No. fittings minimum.

Top Hung Locking:Cockspur handles:Sash widths from 1.0 to 1.6m, 2 handles required.

Espagnolette Locking :Espag locks to be used on vents with widthsgreater than 1.6m and heights less than 1.4m

Multipoint locking :Multipoint locking to be used on vents over 1.4mhigh use sash reference TS6 912

Side Hung Locking:Cockspur handles:Sash heights from 0.8 to 1.4m, 2 handles required.

Espagnolette Locking :Espag locks to be used on vents with heightsgreater than 1.4m.

INTERLOCKING WEDGE Ref LWBK / LWWK :Top hung:A. Up to 1.0m wide: 2 No. interlocks, 1 in 50mm from

each end.B. 1.0m to 1.6m wide: 3 No. interlocks, 1 in the centre and

1 in 50mm from each end.

Side hung:A. Up to 1.0m high: 2 No. interlocks, 1 in 50mm from

each end.B. 1.0m to 1.6m high: 3 No. interlocks, 1 in the centre and

1 in 50mm from each end.

Hinge protectors:For Q mark & security windows , fit hingeprotectors, Hinge protectros to be located within75mm of each friction stay.

Angle ofopening

Maximumweight (kg)

MaximumWidth (mm)

MaximumHeight (mm)TOP HUNG

HD 26

HD 28

2010018001600

1600 2000 100 15

Profile reference: TS6 912

Maximumweight (kg)

HD 10

TOP HUNG

6501500

HD 16 8001500

MaximumHeight (mm)

MaximumWidth (mm)

Angle ofopening

SIDE HUNG MaximumWidth (mm)

MaximumHeight (mm)

Angle ofopening

Maximumweight (kg)

34.5650 1400

42765 1550

HD 10

HD 16

Profile reference: HL 963

Profile reference: HL 963,

SIDE HUNG MaximumWidth (mm)

MaximumHeight (mm)

Angle ofopening

Maximumweight (kg)

34.5650 1530

42765 1620

HD 10

HD 16Profile reference: TS6 915, TS6 913, TS6 923,

Profile reference:TS6 915, TS6 913, TS6 923, TS6 912

Maximumweight (kg)

HD 10

TOP HUNG

7501800

HD 22 SB

HD 16 8001800

1600 1500

MaximumHeight (mm)

MaximumWidth (mm)

Angle ofopening

100 @ 20°80 @ 40° 20 & 40°

- 1500100 @ 20°80 @ 40° 20 & 40°HD 22 SB

HD 22 SB - 1500 100 @ 20°80 @ 40° 20 & 40°

50° or84°30°, 50°or 90°

50kg @ 50°40kg @ 84°100kg @ 30°55kg @ 50°50kg @ 90°

50kg @ 50°40kg @ 84°100kg @ 30°55kg @ 50°50kg @ 90°

50° or84°30°, 50°or 90°

HD 10 7501900

HD 16 8001900

50kg @ 50°40kg @ 84°100kg @ 30°55kg @ 50°50kg @ 90°

50° or84°30°, 50°or 90°

50° or 84°

30°, 50° or 90°

50° or 84°

30°, 50° or 90°

SECTION WEIGHTS:A. Allow 2.2 kg/lm for TS6 915, TS6 913 & TS6 923B. Allow 1.5 kg/lm for HL 963C. Allow 2.30 kg/lm for TS6 912

HD 28 1400 1700 100 kg 15°

SIDE HUNG MaximumWidth (mm)

MaximumHeight (mm)

Angle ofopening

Maximumweight (kg)

30.0700 1200

40.0900 1300

HD 12E

HD 16E

Profile reference:TS6 915, 913, 923, 912 & HL 963

84°

88°

HD EGRESS HINGE

Glazing options - TS202 / TS6 011Scale 1:2

Page : 2.4.07

TS 66 ENERGY CASEMENT WINDOW SYSTEM

Revision : F (--/--/--)

HL 502

8467 8468

HL 501-S

8467 846848

44

HL 506

408467 8468

HL 561

846828

TS6 20244mm glazed unit

TS6 20248mm glazed unit

TS6 20240mm glazed unit

TS6 20228mm glazed unit

8467

40

60

73

53

TILT & TURN / DOOR FRAMETS6 011

TS4 202OUTER FRAME

Glass level

Glass level

45

58

8467 30

HL 561

3813

HL 506

8467

TS6 20238mm glazed unit

Carrawedge

38

TS6 20230mm glazed unit

TS6 20235mm glazed unit

84688467

HL 565

35

32 Carrawedge

TS6 20232mm glazed unit

HL 565

14

10

28

21

16

HL 502

448467 8468

84688467

HL 501-S

48

40

HL 506

8467 8468

288467

HL 561

8468

TS6 90044mm glazed unit

TS6 90048mm glazed unit

TS6 90040mm glazed unit

TS6 90028mm glazed unit

TS6 90035mm glazed unit

Page : 2.4.08Revision : D (--/--/--)

Glazing options - TS6 900Scale 1:2

TS 66 ENERGY CASEMENT WINDOW SYSTEM

TS6 90038mm glazed unit

HL 506

8467 Carrawedge

38

8467 30

HL 561

3813

TS6 90030mm glazed unit

84688467

HL 565

35

TS6 900 no longer available

Glazing options - TS6 915Scale 1:2

TS 66 ENERGY CASEMENT WINDOW SYSTEM

Page : 2.4.09Revision : E (--/--/--)

TS6 91544mm glazed unit

44

HL 502

8467 8468

488467 8468

HL 501-S

408467 8468

HL 506

TS6 91540mm glazed unit

84688467 28

HL 561

TS6 91528mm glazed unit

TS6 91535mm glazed unit

TS6 91532mm glazed unit

TS6 91548mm glazed unit

TS6 91538mm glazed unit

HL 506

8467 Carrawedge

38

TS6 91530mm glazed unit

8467 30

HL 561

3813

84688467

HL 565

35

32 Carrawedge

HL 565

TS6 913 / TS6 923

7257

5

TS 66 ENERGY CASEMENT WINDOW SYSTEMGlazing optionsScale 1:2

Page : 2.4.10Revision : G (--/--/--)

488467 8468

HL 501

TS6 913 / 923 / 91244mm Triple glazed unit

24

24

8467

24

8467

24

8467

24

44 8468

HL 502

408468

HL 506

HL 506

Carrawedge

38

TS6 913 / 923 / 91240mm Triple glazed unit

TS6 913 / 923 / 91238mm Triple glazed unit

TS6 913 / 923 / 91248mm Triple glazed unit

8467

24

TS6 913 / 923 / 91228mm Double glazed unit

8467

24

TS6 913 / 923 / 91230mm Double glazed unit

8467

24

TS6 913 / 923 / 91232mm Double glazed unit

8467

24

TS6 913 / 923 / 91235mm Double glazed unit

8468

HL 565

35

32Carra wedge

HL 565

30

HL 561

3813

28 8468

HL 561

5

87

72

TS6 912

Note A:For use of alternative drainagearrangements please consult our technicaldepartment.

Note B:Slots and drainage holes to be staggeredby 150mm minimum

Note C:Cavity separator under sash used for ratedwindows - optional on standard windows.

At each end of the transom, notch anextra 6 x 8mm slot or drill 8mm hole toallow for extra room for drainage

20 X 25mm slot drilled thru'frame (avoid drilling strip)

20mm notch in bead hook. Bead hooknotched so it is flush with horizontalsurface of transom, seal gasket andgasket channel on sash to becompletely cut away in same locationas notch

01

02 5 x 25mm slot withdrainage cap

01

02

03

03

01

01

01

02

02

04

04

01

02

01

04

04

01

03

TS 66 ENERGY CASEMENT WINDOW SYSTEMDrainage treatmentScale NTS

Page : 2.4.11Revision : F (--/--/--)

185

01

02

05

8mm Ø drilled through sash as400mm c/c approx.

05

TS6 913 & allsash profiles

01

02

05

01

02

02

TS6 202Externally glazed

TS6 202Internally glazed

TS6 302Externally glazed

TS6 302Externally glazed

TS6 302With sash profile

TS6 302Internally glazed(Zone drain each transom)

TS6 302Internally glazed(End drain each transom)

TS6 321Externally glazed

TS6 321Externally glazed

TS6 202 / TBS 161Internally glazed

TS6 202 / TBS 151Internally glazed

TS6 202 / TS4 230

TS6 209Externally glazed

TS6 20910Internally glazed

01

01

02

02

Note A:For use of alternative drainage arrangementsplease consult our technical department.

Note B:Slots and drainage holes to be staggered by150mm minimum

Note C:Cavity separator under sash used for ratedwindows - optional on standard windows.

At each end of the transom, notch anextra 6 x 8mm slot or drill 8mm hole toallow for extra room for drainage

20 X 25mm slot drilled thru'frame (avoid drilling strip)

20mm notch in bead hook. Bead hooknotched so it is flush with horizontalsurface of transom, seal gasket onsash to be completely cut away insame location as notch

01

02 5 x 25mm slot withdrainage cap

03

04

TS 66 ENERGY CASEMENT WINDOW SYSTEMDrainage treatmentScale NTS

Page : 2.4.12Revision : E (--/--/--)

8mm Ø drilled through sash as400mm c/c approx.

05

01

01

01

01

05

05

05

02

02

02

02

04

04

04

04

01

03

TS6 302 / TBS 151Sash reverser

TS6 302 / TBS 151Sash reverser

TS6 302 / TBS 151Sash reverser

02TS6 202 / TBS 151Sash reverser

01

02

01

02

05

TS6 302 / TBS 161Rebate reverser

TS6 302 / TBS 161Rebate reverser

TS6 302 / TBS 161Rebate reverser

TS6 202 / TBS 161Rebate reverser

TS 66 ENERGY CASEMENT WINDOW SYSTEMInternally beaded optionsSash reverser / Rebate reverser locationsScale NTS

Page : 2.4.13Revision : B (--/--/--)

RR - Rebate reverser - TBS 161SR - Sash reverser - TBS 151

RR

Rebate reverser or Sashreverser

SR

SR

RR Rebate reverser or Sashreverser

Rebate reverser or Sashreverser

Rebate reverser or Sashreverser

SR

SR

Note:Sash for internally beaded optionsTS6 913, TS6 923 or TS6 911

Equal leg frame with standard sash TS6202 - TS6900Scale 1:2

Page : 2.4.14

02

03

05

06

08

02

03

06

05

07

08

07

0104

01 04

TS 66 ENERGY CASEMENT WINDOW SYSTEM

Revision : D (--/--/--)

TS6 202

TS6 900HL 561

28

TS6900

36

HL 561

28

TS6FA

TS6FA

36

HL 561

28

TS6FA

TS6FA

HL 561

HL 561HL 561

HL 561

HL 561

TS6F

A

HL

561

36

28

HL 561

3362

95

605

81

60

45

28

40

7636

148

322 76

112

96

6096

110

HL 561

28

TS6FAUnequal leg optionTS6 321

5675

TS6 202 TS6 321

TS6 30276

TS6 302

TS6 302

TS6 900 no longer available

Revision : E (--/--/--)Page : 2.4.15

TS6 202 With TS 915 (fixed light externally beaded)Scale 1:2

01

03 04

05

02

TS 66 ENERGY CASEMENT WINDOW SYSTEM

01

02

03

8468

TS6 915

TS6 202

TS6 915

TS6 915

TS6 600Option with drain tray

7

4141

7

TS6FA

04

TS6FA

HL 561

60

45

28

40

TS6FA

101

60

HL 561

HL 561

28

HL 561

76 159

41

TS6FA

TS6 202

60

HL 561

28

HL 56128

HL 56128

04

04

5675

92

60

TS6 302

TS6 321

TS6 202 TS6 202

05

TS6

915

HL

561TS

6 91

5

HL

561

28

50

67 22 67

TS6 315

TSCS2

Note:As an optional extra, the cavityseparator (TSCS2) can be fittedbetween the sash and the frame so asto improve the thermal performance ofthe window.

01

02

03

05

04

0809 07

Page : 2.4.16Revision : D (--/--/--)

TS6 202 with HL 963 (slim line tee sash)Scale NTS

TS 66 ENERGY CASEMENT WINDOW SYSTEM

06

TS6 FA - Optional01

02

03

HL 963 HL 561

HL 963

HL 563

TS6 302

TS6 202

HL 963

HL 561

HL 963

HL 563

TS6 302

TS6 202

28

HL 963

TS6 2023352

85

HL 963

5222

52

126

85

Dummy sash clipfitted aroundfixed panes

04

05

06

2460

2576

2485

12685 85

TS6 202 TS6 202TS6 315

HL 963 HL 963 HL 963 HL 963

HL 561 HL 561

HL 563HL 563

HL 561 HL 561 HL 561 HL 561

070809

HL 963

HL 963

F/P

F/P F/P

S/H

F/P - Fixed paneS/H - Sash

Dummy sash clipfitted aroundfixed panes

TSCS2

Note:As an optional extra, thecavity separator (TSCS2)can be fitted between thesash and the frame so asto improve the thermalperformance of thewindow.

Revision : E (--/--/--)Page : 2.4.17

TS6 202 With TS6 913 (fixed light externally beaded)Scale 1:2 01

02

03 04

05

TS 66 ENERGY CASEMENT WINDOW SYSTEM

02

03

05TS6 913

TS6 913

TS6 315

TS6 913

725

7

7

72

45

72

288467 8468

HL 561

TS6FA

HL 56128

TS6 202

TS6FA

60HL 561

2804

50

HL 561

28

288467 8468

HL 561

28

8467

8468

TS6 202

TS6 600Option with drain tray

TS6FA or TS6FAC

04

TS6FA

HL 561

60

45

28

40

HL 56128

HL 56128

04

045675

92

60

66

4476

120

TS6 302

TS6 202

28

24

120

TS6 321

TSCS2

Note:As an optional extra, the cavityseparator (TSCS2) can be fittedbetween the sash and the frame so asto improve the thermal performance ofthe window.

Page : 2.4.18Revision : F (--/--/--)

TS6 202 With TS6 912 (fixed light externally beaded)Scale 1:2

03 04

05

02

01

TS 66 ENERGY CASEMENT WINDOW SYSTEM

TS6 202

TS6 600Option with drain tray

TS6FA

04

TS6FA

HL 561

60

4540

HL 56128

HL 56128

04

04

5675

92

60

02

03

TS6 315

7

TS6FA

HL 56128

TS6 202

TS6FA

60

HL 56128

04

50

HL 561

28

66

76

TS6 302

TS6 202

28

24

TS6 912

128

8467 WedgeCarra

TS6 912

8467 Wedge

Carra

TS6 912

8467

WedgeCarra

48 87135

554

05

5

54

120

33

60

28

TS6 321

Option with un-equal leg frame

TSCS2

Note:As an optional extra, the cavityseparator (TSCS2) can be fittedbetween the sash and the frame so asto improve the thermal performance ofthe window.

28

28

28

01

02

03

05

04

0809 07

Page : 2.4.19Revision : E (--/--/--)

TS6 202 with TS6 913 (Internally beaded window using TBS 161)Scale NTS

TS 66 ENERGY CASEMENT WINDOW SYSTEM

TS6 913

TS6 202

HL 561

HL 562

TBS 161

HL 562 HL 562

TBS 161

HL 562

TBS 161

06

HL 562

TBS 161

TS6 202

HL 561

TS6 913

TS6 315

HL 561

TBS 161

TS6 202

TS6 FA - Optional

HL 561

TS6 302

TS6 913

HL 561

HL 561

TS6 913

TS6 202

TBS 161

TBS 161

TBS 161

TS6 302

TS6 202

TS6 202

HL 562

HL 562

HL 562

3937

76

3372

105

7222

72

167

108

105

1377265

50

28

105

01

02

03

04

05

06

0910

07

08

0910

TS6 315

TSCS2

Note:As an optional extra, the cavityseparator (TSCS2) can be fitted betweenthe sash and the frame so as to improvethe thermal performance of the window.

04

05

03

01

02

03 03

05

04

06

08 09

07 0607

0809

TS6 202

TS6 202

01

TS6 913

TBS 151

TS6 302

TBS 151

32

TS6 302

TBS 151TBS 151

REVERSER MULLIONTS6 319

TS6 202

Page : 2.4.20Revision : D (--/--/--)

TS6 202 with TS6 913 (Internally beaded window using TBS 151)Scale NTS

TS 66 ENERGY CASEMENT WINDOW SYSTEM

TS6 202

141

6972

53

4040

44

125

TS6 202

TS6 913

60

72 69141

76

50

36

66

7660

125

02

06 07

08 0960

TSCS2

Note:As an optional extra, the cavity separator(TSCS2) can be fitted between the sashand the frame so as to improve thethermal performance of the window.

TS6 912 sash with security gearScale 1:2

Page : 2.4.21

TS 66 ENERGY CASEMENT WINDOW SYSTEM

Revision : F (--/--/--)

0403

02

01

VIEW FROM INSIDE

02

01

0304

Titon or Prolineaespag handle

TS6 912

TS6 912TS6 202

TS6FA

120

33

60

TS6F

A

HL 561 TS6 912TS6 202

TS6F

A

HL 561TS6 202

TS6F

A

TS6 202

TS6FA

60TS6 912

119

TSCS2

Note:As an optional extra, the cavityseparator (TSCS2) can be fittedbetween the sash and the frameso as to improve the thermalperformance of the window.

288467 8468

HL 561

288467 8468

HL 561

28

8467

8468

28

28

Transom options & Add on detailsScale 1:2

Page : 2.4.22

TS 66 ENERGY CASEMENT WINDOW SYSTEM

Revision : C (--/--/--)

TS6 080

TS6 08080mm extenderFor extra height on width orjambs or for fitting slotvents to the head of awindow

90mm TransomTS6 390

100mm TransomTS6 340

80

90 100

50

TS6 08580mm extenderFor extra height onwidth or jambs

TS6 085

TS6 30276mm Transom

76

TSCS2

Note:As an optional extra, the cavityseparator (TSCS2) can be fittedbetween the sash and the frame so asto improve the thermal performance ofthe window.

66

TS6 084140mm extenderFor extra height on width orjambs or for fitting slotvents to the head of awindow

140

TS6 084

Detail into brick / blockwork.Scale NTS

Page : 2.4.23

TS 66 ENERGY CASEMENT WINDOW SYSTEM

Revision : C (--/--/--)

Membrane Clamped to backof lug adapter and bondedback to structure (Air seal)

Fixings to besuitable forintended use.

Continuous LM sealFoam fillinsulation orsimilar to avoidcold bridging

Membrane Clamped to backof lug adapter and bondedback to structure (Air seal)

Membrane Clamped to backof lug adapter and bondedback to structure (Forweather seal)

Window fixed to structurewith fixing straps at 600mmc/c max (See drawing 2.4.28for more detailed instructionon fitting)

TS6202

TS6202

TSCS2

Note:As an optional extra, thecavity separator (TSCS2) canbe fitted between the sashand the frame so as toimprove the thermalperformance of the window.

Add on detailsScale NTS

Page : 2.4.24

TS 66 ENERGY CASEMENT WINDOW SYSTEM

Revision : F (--/--/--)

Fixing lugdetail

3821 gasketfitted to sealfor extraweathering Continuous

l.m. siliconeseal

FRAME TO TS CILL (TS4 230)

TS CILL

TB6 802

TS6 202

TS Drain trayTS6 600

18

33

TS6 202

90 degree corner post TB6 802

Ixx = 13.85 cm4In line Coupler - TS6 350

50

50mm coupler - TS6 351Ixx = 69.63 cm4

66

End cap for TS4 230(TSA 030 - Standard)(TSA 031 - with drip piece)

l.m. seal

l.m. seal

l.m. seal

4

52452

125

9030

59

60 60

l.m. seal

l.m. seal

459 59

100

Ixx = 249 cm4100mm coupler - TS6 352

l.m. seal

l.m. seal

459 59

TS6 353100mm slim COUPLERIxx = 185.65 cm4Iyy = 7.38 cm4

XT6 800Bay pole detail, suitable forangles between 115 to 180°

XT6 810Fillet

XT6 811Packer

115°

Revision : F (--/--/--)Page : 2.4.25

Butt hinge optionsScale NTS

TS 66 ENERGY CASEMENT WINDOW SYSTEM

TS butthinge

Note 1:When fitting the TS butt hinge to atransom, move the drip section so asthe drip does not interfere with thehinge

Note 2:The TS butt hinge is not suitablewhere the is a sash over a sash. thespace between sashes will not allowfitting of the hinge

21

TS6FA

Crest hinge

Crest hinge

TS6 202

TS6 915

TS6 202

TS6 202

TS6 202

TS6 915

TS6 913

TS6 912

TSCS2

Note:As an optional extra, the cavityseparator (TSCS2) can be fitted betweenthe sash and the frame so as to improvethe thermal performance of the window.

TS butthinge

Curtain wall insert detailsScale 1:2

Page : 2.4.26

TS 66 ENERGY CASEMENT WINDOW SYSTEM

Revision : D (--/--/--)

HL 963HL 563

HL 561

28

TS6 915

HL 963

TS6 913

TS6 912

TS6 209TS6 209

TS6 209

96

5799

113

11

11

11

11

76

HL 561

HL 56128 TS6 302

HL 56128

HL 56128

HL 561

28

Revision :Page : 2.4.27

XT6 200 With TS6 913 (fixed light externally beaded)Scale 1:2

TS 66 ENERGY CASEMENT WINDOW SYSTEM01

02

03 04

05

XT6 200

52

66

TS6 302

XT6 200

52

52

66

XT6 200

18

52

3385

XT6 200

TS6 600

TS6 913

72

288467 8468

HL 561

97

02

TS6 913

72

288467 8468

HL 561

4412

0 05

TS6 913

TS6 315

7

4550

HL 561

28

28

8467

8468

28

24

120

01

03 04

04

HL 56128

52

66

XT6 200

04XTDRIP

TSCS2

Note:As an optional extra, the cavityseparator (TSCS2) can be fittedbetween the sash and the frame so asto improve the thermal performance ofthe window.

Detail into brick / blockwork.Scale 1:2

Page : 2.4.28

TS 66 ENERGY CASEMENT WINDOW SYSTEM

Revision :

Membrane Clamped toback of lug adapter andbonded back tostructure (Air seal)

Membrane Clamped into lugadapter and bonded back tostructure (For weather seal)

100m

m m

in.

125

± 25

600

max

125

± 25

125

± 25

125 ± 25

125

± 25

Fixing distances for aluminium windows and doors as per BS 8213-4:2007Wherever practicable all four sides of the frame should be secured as follows:

1. Corner jamb fixings should be between 100mm and 150mm from the external corner2. No fixings should be less than 100mm from the centre line of a mullion or transom3. Intermediate fixings should be at centres no greater than 600mm4. There should be a minimum of two fixings on each jamb.5. On windows over 1800mm wide, central head and sub sill fixings should be provided.

Alternatively, apply a suitablesilicone sealant around theperimeter of the frame andstructure (on the outside).

TSCS2

Note:As an optional extra, thecavity separator (TSCS2)can be fitted between thesash and the frame so as toimprove the thermalperformance of the window.

TS 66 ENERGY CASEMENT WINDOW SYSTEMGlazingScale NTS

Page : 2.4.29Revision : C (--/--/--)

Indicates spacer onlyIndicates load bearing packer

Fixedpane

Sidehung

Tophung

Note: Load bearing packers to belocated close to gearing points,typically 160mm from edge.

Standard 5mmpvc glass packer

11

Standard11mm pvcglass packer

Standard 5mm pvcglass packer

Standard 5mm& 4mm pvcglass packer

TS6 202

5

5

5

TS6 915

TS6 913

TS6 912

TS6 202

TS6 202

TS6 202

Notes:1. Ensure glass packers do not cover

drainage slots and holes.2. Silicone should not be used when fitting

glass packers as excessive amounts mayhinder drainage.

3. Packers to be of suitable material and fitfor purpose.

4. Refer to BS 8213-4:2007, BS 6262 & BS8000-7 for further recommendations.

5. In addition to the above any glass orinsulating glass unit manufacturer'sinstructions should be followed.

TS6 202 With TS6 923 (fixed light externally beaded)Scale 1:2 01

02

03 04

05

TS 66 ENERGY CASEMENT WINDOW SYSTEM

02

05TS6 923

TS6 913

TS6 302

7

72

45HL 561

28

TS6 202

60HL 561

2801

HL 561

28

288467 8468

HL 561

28

8467

8468

TS6 202

TS6 600Option with drain tray

HL 56128

04

92

60

66

4476

120

TS6 302

120

TS6 202

TS6 600Option with drain tray

92

60772

288467 8468

HL 561

Page : 2.4.30Revision :

03

TSCS2

Note:As an optional extra, the cavityseparator (TSCS2) can be fittedbetween the sash and the frame so asto improve the thermal performance ofthe window.

TS6FA

04

TS6FA

HL 561

60

4540

HL 56128

04

5675

28

TS6 321

Option with un-equal leg frame

TS 66 ENERGY CASEMENT WINDOW SYSTEMCill Options without dripScale NTS

Page : 2.4.31Revision : A (--/--/--)

CILLE60Cill Extender

145

100

60

30

170

230

XT6260Riser section

XT6260Riser section

XT6260Riser section

XT6260Riser section

XT6260Riser section

XT6260Riser section

CILL170170mm Cill

CILL100100mm Cill

CILL06060mm Cill

CILL145145mm Cill

CILL03030mm Cill

XT6260Riser section

CILL120120mm Cill

120

CILLEC230SCill end cap

CILLEC145SCill end cap

CILLEC120SCill end cap

CILLEC100SCill end cap

CILLEC060SCill end cap

CILLEC030SCill end cap

28

CILL200200mm Cill

200

CILLEC200SCill end cap

CILLEC170SCill end cap

TS 66 ENERGY CASEMENT WINDOW SYSTEMCill Options with dripScale NTS

Page : 2.4.32Revision : A (--/--/--)

CILLE60Cill Extender

170

145

100

60

30

170

230

XT6260Riser section

CILL170170mm Cill

CILL170170mm Cill

CILL100100mm Cill

CILL06060mm Cill

CILL145145mm Cill

CILL03030mm Cill

CILL120120mm Cill

120

CILLEC170DCill end cap

CILLEC145DCill end cap

CILLEC120DCill end cap

CILLEC100DCill end cap

CILLEC060DCill end cap

CILLEC030DCill end cap

Drip15Drip section

CILLEC230DCill end cap with drip

15

Drip1515mm Dripsection

28