Page 1: an EnPro Industries company - Michigan Air Solutions · 2017. 1. 1. · an EnPro Industries company STANDARD LINE — SPECIFICATIONS & ENGINEERING DATA Grade 10 1⁄ 4 10 17 Grade

FILTERS

COALESCERS

ABSORBERS

ELEMENTS

MIST ELIMINATORS

an EnPro Industries company

an EnPro Industries company

Page 2: an EnPro Industries company - Michigan Air Solutions · 2017. 1. 1. · an EnPro Industries company STANDARD LINE — SPECIFICATIONS & ENGINEERING DATA Grade 10 1⁄ 4 10 17 Grade

COMPRESSED AIR FILTERS

STANDARD FILTERS

Quincy DCN Series

Particulate/Coarse Coalescers are designed to

remove solids, burnt oil and bulk liquids.

Quincy CSN, CPN, CXN Series

Coalescers remove various levels of liquid aero-

sols and mist.

Quincy ACN Series

Activated Carbon Absorbers remove vapors

and odors.

• 10 scfm to 16,500 scfm

• 230psigmax.workingpressure

for threaded filters

• 150psigmax.workingpressure

for flanged filters

• Aluminumhousing(1⁄2”to3”NPT)

• Steelhousing(3”to12”FLG)

MOISTURE SEPARATORS

• 20to1500scfm,230psig

• Aluminumhousing(1⁄4”to3”NPT)

OVER & UNDER

COALESCER/ABSORBER

COMBINATION

• 10to50scfm/230psig

• Two-in-onedesign

PORTABLE AIR SYSTEMS

FOR PAINT OR SANDBLAST

APPLICATIONS

• 15cfmtwo-portmanifold

• 30scfm,four-portmanifold

• 230psigmax.workingpressure

• Floorstandorwallmountingbrackets

• Airpressureregulator

• Airpressuregauge

• Availableairheater

HIGH-TEMPERATURE DUST FILTER

• +450°F/150psig

• 15to1600scfm

Quincy filters protect pneumatic equipment

and processes from the harmful effects of con-

taminated compressed air by removing dirty

water, burnt oil and solid pollutants before

they can do any damage. Clean compressed air

will result in improved production and reduced

operating costs. World class, state-of-the-art

material and design make Quincy compressed

air filters the standard to which all others must

be compared.

QuincyCompressor.com | Made in the U.S.A. | The Science of Compressed Air 2

Page 3: an EnPro Industries company - Michigan Air Solutions · 2017. 1. 1. · an EnPro Industries company STANDARD LINE — SPECIFICATIONS & ENGINEERING DATA Grade 10 1⁄ 4 10 17 Grade

an EnPro Industries company

ELEMENT CONSTRUCTION

Push-to-Fit Design — Aluminum Filters

• Easyelementreplacement

• Fitintegrityeliminatesleaks,

saving energy

Stainless Steel Support Core

• Providesstrength

• Eliminatescorrosion

• Protectselementfrombursting

under high differential pressure

1st Stage Pre-Filtration Support Layer

• Captureslargercontaminants

• Protects2ndStagefiltrationmedia

• Extendsservicelife

Multiwrap 2nd Stage

• Highvoidvolumeminimizes

pressure drop, saving energy

• Increasedsurfaceareaensures

maximum contaminant retention

• Extended life construction

• Deepbedprovidesoptimum

coalescing efficiency

• Selectedmediacombinations

provide precise filtration solutions

3rd Stage Interceptor Layer

• Providesadditionalstrength

• Optimizesinterceptionprocess

4th Stage Outer Stainless Steel Support

• Ensures total element integrity

Inside to Out Flow

• Prolongselementlifeand

improves drain performance

Polyester Needle Felt Drainage Layer

• Optimumoilremoval

• Hightemperaturetolerance

• Maximumdurability

• Willnotdisintegrate

• Suitableforusewithmineral

and synthetic oils

• Tolerantinaggressiveenvironments

Glass-Filled Nylon End Caps

• Color-codedforsimpleelement

grade identification

• Easyelementreplacement

• Willnotcorrode

Quincy’s Layered Multiwrap design employs a specially

blended borosilicate glass microfiber media to produce

strong, durable and efficient filter elements. The filtration

media combines high flow rates and high dirt-holding capaci-

ties without compromising element service life. Easy to iden-

tify and easy to install, these highly advanced products offer

the best performance available.

ELEMENTS

3

Page 4: an EnPro Industries company - Michigan Air Solutions · 2017. 1. 1. · an EnPro Industries company STANDARD LINE — SPECIFICATIONS & ENGINEERING DATA Grade 10 1⁄ 4 10 17 Grade

COMPRESSED AIR FILTERS

STANDARD LINE: PARTICULATE – COALESCER – ABSORBER

Quincy’s Standard Filtration lineup consists of

the three most common types of filters used in

compressed air systems. Aluminum housings

with threaded NPT connections are used for

flows up to 1530 cfm and steel housings with

flanged connections are used for flows up to

16,500 cfm.

• Push-to-fitdesignusedonthreadedfiltersforeasyfilterele-

ment replacement

• Multiwrapelementconstructionensuresoptimumperformance

• Modulardesignsavesenergyandallowsforeasyinstallation

of multiple threaded filters

• Aluminumhousingsfeatureelectrophoreticcoatingtoprevent

corrosion

• 10-yearhousingguaranteeonaluminumhousings

• Standardpressuredifferentialindicatoron

aluminum housings

• Standardautomaticcondensatedrainon

aluminum housings

STEEL HOUSINGS, FLANGED CONNECTIONS 1500 TO 16,000 CFM SERIES DCNF, CSNF, CPNF, CXNF AND ACNF

ACNT SERIES

Activated Carbon Absorber

designed to remove vapors

and odors. Installed imme-

datelydownstreamofeithera

CPNT or a CXNT coalescer,

itwillreduceoilcarry-

over to .003 ppm.

• Samefiltrationgradeasaluminumfilters

• Identifiedwithan“F”suffix

• UstampedfortheUSAandCRNapprovedforCanada

• Housingsarefreestandingandtoploadingforeasyelementreplacement

• Allgradesoffilterelementendcapsaremolded,providingstrength,

durability and long life

ALUMINUM HOUSINGS, THREADED CONNECTIONS 10 TO 1530 CFM

QuincyCompressor.com | Made in the U.S.A. | The Science of Compressed Air 4

DCNT SERIES

Designed to remove high

concentrations of solids,

burntoilandbulkliquids

DCNT 5 micron, 5 ppm

CSNT, CPNT, CXNT SERIES

Designed to coalesce various

levels of liquid aerosols. The 1

micron CSN is also an ideal afte

filter for desiccant dryers.

CSNT 1 micron, 0.1 ppm

CPNT .01 micron, .01 ppm

CXNT .01 micron, .001 ppm

Page 5: an EnPro Industries company - Michigan Air Solutions · 2017. 1. 1. · an EnPro Industries company STANDARD LINE — SPECIFICATIONS & ENGINEERING DATA Grade 10 1⁄ 4 10 17 Grade

an EnPro Industries company

STANDARD LINE — SPECIFICATIONS & ENGINEERING DATA

Grade10 1⁄4 10 17 GradeE10 1 3 11⁄2 8 3 1.43 0.65 72 35 210 75Grade20 1⁄4 20 33 GradeE20 1 3 11⁄2 8 3 1.43 0.65 72 35 210 75Grade30 3⁄8 30 50 GradeE30 1 3 11⁄2 8 3 1.43 0.65 72 35 210 75Grade60 1⁄2 60 100 GradeE60 1 31⁄2 11⁄4 13 4 2.87 1.30 88 32 315 100Grade125 3⁄4 125 208 GradeE125 1 5 11⁄2 15 4 5.95 2.70 125 39 365 100Grade150 1 150 250 GradeE150 1 5 11⁄2 15 4 5.95 2.70 125 39 365 100Grade200 1 200 333 GradeE200 1 5 11⁄2 21 6 7.72 3.50 125 39 515 150Grade300 11⁄4 300 500 GradeE300 1 5 11⁄2 21 6 7.72 3.50 125 39 515 150Grade425 11⁄2 425 708 GradeE425 1 51⁄2 2 22 6 9.70 4.40 135 50 545 150Grade500 2 500 833 GradeE500 1 51⁄2 2 22 6 9.70 4.40 135 50 545 150Grade650 2 650 1083 GradeE650 1 51⁄2 2 30 6 11.00 5.00 135 50 745 150Grade800 21⁄2 800 1333 GradeE800 1 8 23⁄4 32 8 25.40 11.50 200 68 805 200Grade1000 3 1000 1667 GradeE1000 1 8 23⁄4 32 8 25.40 11.50 200 68 805 200Grade1300 3 1300 2167 GradeE1300 1 8 23⁄4 37 8 34.20 15.50 200 68 925 200Grade1525 3 1525 2542 GradeE1525 1 9 21⁄2 42 12 41.90 19.00 230 65 1050 300

Metric Element Number Dimensions Dimensions Filter Model Pipe Size Flow Rate Model of A B C D Weight A B C D (Grade) NPT scfm Nm3/hr (Grade) Elements In. In. In. In. lb. kg. mm mm mm mm

Complete Filter Assemblies

DCNE 3 4 5 5.0 5.0 248 120 1 40 1 75 6 400 232 16 GreenCSNE 2 2 1 0.1 0.1 248 120 1 75 2 150 6 400 232 16 RedCPNE 1 1 0.01 0.01 0.01 248 120 2 100 4 300 6 400 232 16 BlueCXNE 1 1 0.01 0.001 0.001 248 120 2 140 5 350 6 400 232 16 BlackACNE 1 1 0.01 0.003 0.003 77 25 1 75 — — Min. every 6 months 232 16 Black

Max. Pressure Loss Max. Element Max. Particle Oil Carryover Max. Change Working End CapFilter Max. Particle Size Oil Content Class Removal at 68˚F at 20˚C Temperature Clean & Dry Wet Element Pressure ColorElement to ISO 8573-1:2001 to ISO 8573-1:2001 in Microns ppm mg/m3 ˚F ˚C psi mbar psi mbar psi mbar psig barg Code

Specs

Grade1503 3 1500 2550 Grade1500 1 58 15 48 10 165 74 1472 381 1219 254Grade1504 4 1500 2550 Grade1500 1 58 171⁄8 48 61⁄2 175 80 1473 435 1219 165Grade2004 4 2000 3400 Grade2000 1 58 213⁄8 481⁄4 13 320 145 1473 543 1226 330Grade2006 6 2000 3400 Grade2000 1 591⁄4 251⁄2 48 71⁄2 360 163 1505 648 1219 191Grade3004 4 3000 5100 Grade3000 1 72 213⁄8 621⁄4 13 385 175 1829 543 1581 330Grade3006 6 3000 5100 Grade3000 1 751⁄4 25.5 64 71⁄2 420 191 1911 648 1626 191Grade4506 6 4500 7650 Grade1500 3 831⁄2 251⁄4 681⁄2 231⁄2 580 263 2121 641 1740 597Grade6008 8 6000 10200 Grade1500 4 863⁄4 25 68 23 650 295 2203 635 1727 584Grade10510 10 10500 17850 Grade1500 7 100 31 80 30 800 363 2540 787 2032 762Grade16512 12 16500 28050 Grade1500 11 1133⁄4 441⁄2 87 16 1000 454 2889 1130 2210 406

Metric Element Number Dimensions Dimensions Filter Model Pipe Size Flow Rate Model of A B C D Weight A B C D (Grade) Flg. scfm Nm3/hr (Grade) Elements In. In. In. In. lb. kg. mm mm mm mm

Steel Housings — Flanged

Operating psig 4 9 15 29 44 58 72 87 100 115 130 145 160 174 189 203 218 232 Pressure barg 0.3 0.6 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Correction Factor 0.21 0.29 0.38 0.53 0.65 0.76 0.84 0.92 1 1.07 1.13 1.19 1.25 1.31 1.36 1.41 1.46 1.51

Formaximumflowrate,multiplymodelflowrateshownintheabovetablebythecorrectionfactorcorrespondingtotheworkingpressure.

Correction Factor

Model Grades 10, 20 & 30 Model Grades 60–1525

Model Grades 1503, 1504 & 2004

A

C

D

B

Model Grades 2006–16512

B

A

C

D

5

Page 6: an EnPro Industries company - Michigan Air Solutions · 2017. 1. 1. · an EnPro Industries company STANDARD LINE — SPECIFICATIONS & ENGINEERING DATA Grade 10 1⁄ 4 10 17 Grade

COMPRESSED AIR FILTERS

HIGH TEMPERATURE:1 MICRON DUST FILTERS,450˚F, 150 PSIG

• Featuresahigh-temperaturedustfilter

withheavy-dutybowl

• Ribbedbowlfacilitatesremovalwhen

changing elements

NOTE:Alloyfiltersshippedloosewillhaveaspecial

high-temperatureblackpowdercoatpaint.

• DesignedspecificallyforHeatReactivatedDesiccantAirDryers

• Nomexouterlayerisprovidedforhigh-temperatureoperation

• Push-to-fitdesignusedonthreadedfiltersforeasyfilterelementreplacement

• Multiwrapelementconstructionprovidesoptimumperformance

ALUMINUM HOUSINGS, THREADED NPT CONNECTIONS 15 TO 650 CFM, SERIES HTDT

• Samefiltrationgradeasaluminumfilters

• Identifiedwithan“F”suffix

• UstampedfortheUSAandCRNapproved

for Canada

• Housingsarefreestandingandtop-loading

for easy element replacement

• Allgradesoffilterelementendcapsare

molded, providing strength, durability

and long life

STEEL HOUSINGS, FLANGED CONNECTIONS 1500 TO 16,000 CFM, SERIES HTDF

QuincyCompressor.com | Made in the U.S.A. | The Science of Compressed Air 6

Page 7: an EnPro Industries company - Michigan Air Solutions · 2017. 1. 1. · an EnPro Industries company STANDARD LINE — SPECIFICATIONS & ENGINEERING DATA Grade 10 1⁄ 4 10 17 Grade

an EnPro Industries company

HIGH TEMPERATURE — SPECIFICATIONS & ENGINEERING DATA

HTDT15 1⁄4 15 25 HTDE15 1 21⁄2 1⁄2 6 2 0.5 0.25 63 15 150 50HTDT30 3⁄8 30 50 HTDE30 1 21⁄2 1⁄2 71⁄2 2 0.6 0.27 63 15 190 50HTDT65 1⁄2 65 108 HTDE65 1 41⁄2 11⁄2 12 6 5.7 2.60 114 38 305 150HTDT75 3⁄4 75 125 HTDE75 1 41⁄2 11⁄2 12 6 5.7 2.60 114 38 305 150HTDT150 1 150 250 HTDE150 1 41⁄2 11⁄2 151⁄2 6 7.3 3.30 114 38 395 150HTDT300 11⁄2 300 500 HTDE300 1 53⁄4 2 21 7 16.5 7.50 146 50 435 170HTDT450 2 450 750 HTDE450 1 53⁄4 2 21 7 16.5 7.50 146 50 435 170HTDT650 2 650 1084 HTDE650 1 53⁄4 2 25 7 22.0 10.00 146 50 635 170

Metric Element Number Dimensions Dimensions Filter Pipe Size Flow Rate Model of A B C D Weight A B C D Model NPT scfm Nm3/hr (Grade) Elements In. In. In. In. lb. kg. mm mm mm mm

Dust Filters — Threaded

HTDF1503 3 1500 2550 HTDE1500 1 58 15 48 10 165 74 1473 381 1219 254HTDF1504 4 1500 2550 HTDE1500 1 58 171⁄8 48 61⁄2 175 80 1473 435 1219 165HTDF2004 4 2000 3400 HTDE2000 1 58 213⁄8 481⁄4 13 320 145 1473 543 1226 330HTDF2006 6 2000 3400 HTDE2000 1 591⁄4 25.5 48 71⁄2 360 163 1505 648 1219 191HTDF3004 4 3000 5100 HTDE3000 1 72 213⁄8 621⁄4 13 385 175 1829 543 1581 330HTDF3006 6 3000 5100 HTDE3000 1 751⁄4 251⁄2 64 71⁄2 420 191 1911 648 1626 191HTDF4506 6 4500 7650 HTDE1500 3 831⁄2 251⁄4 681⁄2 231⁄2 580 263 2121 641 1740 597HTDF6008 8 6000 10200 HTDE1500 4 863⁄4 25 68 23 650 295 2203 635 1727 584HTDF10510 10 10500 17850 HTDE1500 7 100 31 80 30 800 363 2540 787 2032 762HTDF16512 12 16500 28050 HTDE1500 11 1133⁄4 441⁄2 87 16 1000 454 2889 1130 2210 406

Metric Element Number Dimensions Dimensions Filter Pipe Size Flow Rate Model of A B C D Weight A B C D Model Flg. scfm Nm3/hr (Grade) Elements In. In. In. In. lb. kg. mm mm mm mm

Dust Filters — Flanged

High-temperature dust filter element gradeHTDE 1 2 2 450 250 1.1 75 NA NA 6 400 150 10 BrickRed

Max. Pressure Loss Max. Element Particle Oil Carryover Max. Change Working End CapFilter Removal at 68˚F at 20˚C Temperature Clean & Dry Wet Element Pressure ColorElement in Microns ppm mg/m3 ˚F ˚C psi mbar psi mbar psi mbar psig barg Code

Specs

Models HTDT 15 & 30

Models HTDT 65–650

Operating psig 145 290 435 580 725 Pressure barg 10 20 30 40 50 Correction Factor 0.34 0.57 0.71 0.86 1.0

Formaximumflowrate,multiplymodelflowrate shownintheabovetablebythecorrectionfactor correspondingtotheworkingpressure.

Correction Factor

Models HTDF 1503, 1504 and 2004

A

C

D

B

Models HTDF 2006–16512

B

A

C

D

7

Page 8: an EnPro Industries company - Michigan Air Solutions · 2017. 1. 1. · an EnPro Industries company STANDARD LINE — SPECIFICATIONS & ENGINEERING DATA Grade 10 1⁄ 4 10 17 Grade

PORTABLE AIR SYSTEMS

15 TO 30 CFM

Quincy Portable Air Packages are complete

systems designed to provide, clean, odor-

free, taste-free, particle and liquid oil-free

compressed air for sand blasting and/or paint-

ing hoods. The 15-cfm system has two outlet

ports and can accommodate two sets. The

30-cfm package has four outlet ports and can

accommodate four sets. The system provides

absolute filtration down to 0.01 micron and

oil removal down to 0.003 ppm.

The System Includes:

• Aluminumhousingswithelectrophoretic

coating to prevent corrosion

• WSNTmoistureseparator

• CSNT1micron,0.1ppmCoalescer

• QUDTwithCPNT0.01micron,0.01ppm

and .003 ppm activated carbon absorber

The System includes:

• CombinationCoalescerandActivatedCarbonAbsorber

• Twofunctionsinoneunit

• Space-savingOver&Underconfiguration

• Push-to-fitdesignforeasyfilterelementreplacement

• Multiwrapelementconstructionensuresoptimumperformance

• Non-shedding,high-speedcarbongranulesincreasevapor-holdingcapacity

• Aluminumhousingswithelectrophoreticcoatingtopreventcorrosion

• Standardpressuredifferentialindicator

• Standardautomaticcondensatedrain

Using a unique two-sided head, Quincy’s Over & Under Duplex filter

combines a CPN Series (0.01-micron, 0.01-ppm) coalescer with an

ACN Series (.003-ppm) activated carbon absorber. This compact, two-

stage, single-piece filtration system saves space, is easy to install and

delivers ISO 8573.1 class 1 compressed air. The Over & Under is ideal

for food and beverage, instrumentation and pharmaceutical applications.

OVER & UNDER DUPLEX

10 TO 50 CFM, SERIES OUDT

COMPRESSED AIR FILTERS

• Push-to-fitdesign

• PNF drain layer

• Color-codedendcaps

• Pressuredifferentialindicator

• Multiwrapconstruction

• Airpressureregulatorandgauge

• Activatedcarbonelementimpregnated

withreddyeoilindicator

• Compressedairheateroption

• Wallmountingorfloor-mounting

configuration

QuincyCompressor.com | Made in the U.S.A. | The Science of Compressed Air 8

Page 9: an EnPro Industries company - Michigan Air Solutions · 2017. 1. 1. · an EnPro Industries company STANDARD LINE — SPECIFICATIONS & ENGINEERING DATA Grade 10 1⁄ 4 10 17 Grade

an EnPro Industries company

WARNING: The Portable air systems described in this brochure willnotremovecertaintypesofgases,includingCarbonMon-oxide (CO)andCarbonDioxide (CO2). These Air Systems are designed to offer the user protection in potentially harmful environments. It is therefore imperative the products be cor-

rectly installed and properly controlled by a competent person. Properly controlled means the equipment installed should be fullycheckedpriortoeveryuse.Shouldanyfaultbediscovered,it must be repaired or the failed component replaced to guaran-teefullworkingorderbeforeuse.

Wallmounted Portable Air PackagesBWST15 1⁄4 2 15 25 BAEK 15 1 Kit 101⁄4 123⁄4 123⁄4 3 0.50 0.25 280 360 323 77BWHT15 1⁄4 2 15 25 BAEK 15 1 Kit 153⁄4 18 131⁄4 4 0.60 0.27 418 498 337 100BWST30 3⁄8 2 15 25 BAEK 30 1 Kit 101⁄4 123⁄4 123⁄4 3 5.70 2.60 280 360 323 77BWHT30 3⁄8 2 15 25 BAEK 30 1 Kit 153⁄4 18 131⁄4 4 5.70 2.60 418 498 337 100

Frame-Mounted Portable Air PackagesBFST 15 1⁄4 4 30 50 BAEK 15 1 Kit 193⁄4 NA 173⁄4 193⁄4 2.35 1.05 500 NA 450 500BFHT15 1⁄4 4 30 50 BAEK 15 1 Kit 193⁄4 NA 173⁄4 193⁄4 2.35 1.05 500 NA 450 500BFST 30 3⁄8 4 30 50 BAEK 30 1 Kit 193⁄4 NA 173⁄4 193⁄4 2.35 1.05 500 NA 450 500BFHT30 3⁄8 4 30 50 BAEK 30 1 Kit 193⁄4 NA 173⁄4 193⁄4 2.35 1.05 500 NA 450 500

Metric Pipe Air Element Number Dimensions Dimensions Filter Size Outlet Flow Rate Model of A B C D Weight A B C D Model NPT Ports scfm Nm3/hr (Grade) Elements In. In. In. In. lb. kg. mm mm mm mm

Portable Air Packages

Operating psig 4 9 15 29 44 58 72 87 100 115 130 145 160 174 189 203 218 232 Pressure barg 0.3 0.6 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Correction Factor 0.21 0.29 0.38 0.53 0.65 0.76 0.84 0.92 1.0 1.07 1.13 1.19 1.25 1.31 1.36 1.41 1.46 1.51

Formaximumflowrate,multiplymodelflowrateshownintheabovetablebythecorrectionfactorcorrespondingtotheworkingpressure.

Correction Factor

Portable Air Package KitBAEK 1 1 >0.01 >0.003 >0.003 77 25 3.7 250 6.6 950 Min. every 6 months 145 10 Red/Blue/Black

Duplex Filter Kit (OUDK)CPNE 1 1 0.01 0.01 0.01 248 120 2.2 150 4.4 300 6 400 232 16 BlueACDE 1 1 0.01 0.003 0.003 77 25 1.1 75 NA NA Min. every 6 months 232 16 Black

Max. Pressure Loss Max. Element Max. Particle Oil Carryover Max. Change Working End CapFilter Max. Particle Size Oil Content Class Removal at 68˚F at 20˚C Temperature Clean & Dry Wet Element Pressure ColorElement to ISO 8573-1:2001 to ISO 8573-1:2001 in Microns ppm mg/m3 ˚F ˚C psi mbar psi mbar psi mbar psig barg Code

Specs

OUDT10 1⁄4 10 17 OUDK10 1Kit 3 6 7 3 1.90 0.85 72 150 173 75OUDT15 1⁄4 15 25 OUDK15 1Kit 3 6 7 3 1.90 0.85 72 150 173 75OUDT30 3⁄8 30 50 OUDK30 1Kit 3 6 7 3 1.90 0.85 72 150 173 75OUDT50 1⁄2 50 83 OUDK50 1Kit 31⁄2 8 9 4 2.75 1.25 90 200 225 100

Metric Element Number Dimensions Dimensions Filter Pipe Size Flow Rate Model of A B C D Weight A B C D Model NPT scfm Nm3/hr (Grade) Elements In. In. In. In. lb. kg. mm mm mm mm

Over & Under Duplex

Models BWST 15 & 30

Models BFST 15 & 30

Models OUDT 10–50

PORTABLE AIR, OVER & UNDER DUPLEX — SPECIFICATIONS & ENGINEERING DATA

9

Page 10: an EnPro Industries company - Michigan Air Solutions · 2017. 1. 1. · an EnPro Industries company STANDARD LINE — SPECIFICATIONS & ENGINEERING DATA Grade 10 1⁄ 4 10 17 Grade

COMPRESSED AIR FILTERS

QuincyCompressor.com | Made in the U.S.A. | The Science of Compressed Air 10

MECHANICAL MOISTURE SEPARATORS

20 TO 1500 CFM, 230 PSIG, SERIES WSNT

Quincy Mechanical Moisture Separators are

designed to remove bulk liquids and large

volumes of water. They are typically installed

downstream of aftercoolers, air receivers, refrig-

erated air dryers and at strategic points of use

throughout the compressed air distribution

system. The design employs an internal spin-

ner to create a centrifugal action that effectively

removes large quantities of water.

• Largesumpandquietzonetopreventmoisture

re-entrainment

• Modulardesignallowsforeasyinstallation

of multiple housings and saves energy

• AnnularsealandcaptiveO–ringpreventleaks

• Aluminumhousings(1⁄4”to3NPT)feature

electrophoretic coating to prevent corrosion

• Aluminumhousings(1⁄4”to3”NPT)carry

a 10-year housing guarantee

• Standardautomaticcondensatedrain

Metric Dimensions Dimensions Filter Pipe Size Flow Rate A B C D Weight A B C D Model NPT scfm Nm3/hr In. In. In. In. lb. kg. mm mm mm mm

Moisture Separators

Operating psig 4 9 15 29 44 58 72 87 100 Pressure barg 0.3 0.6 1 2 3 4 5 6 7 Correction Factor 0.21 0.29 0.38 0.53 0.65 0.76 0.84 0.92 1

Operating psig 115 130 145 160 174 189 203 218 232 Pressure barg 8 9 10 11 12 13 14 15 16 Correction Factor 1.07 1.13 1.19 1.25 1.31 1.36 1.41 1.46 1.51

Formaximumflowrate,multiplymodelflowrateshownintheabovetablebythecorrectionfactorcorrespondingtotheworkingpressure.

Correction Factor

WSNT 248 120 35 1.5 0.7 50 232 16

Max. Min. Typical Max. Recommended Recommended Pressure Loss WorkingFilter Operating Temp. Operating Temp. At Rated Flow PressureModel ˚F ˚C ˚F ˚C psi mbar psig barg

Specs

SPECIFICATIONS & ENGINEERING DATA

WSNT20 1⁄4 20 35 3 11⁄4 81⁄4 3 1.45 0.65 72 35 210 75WSNT30 3⁄8 30 50 3 11⁄4 81⁄4 3 1.45 0.65 72 35 210 75WSNT63 1⁄2 63 112 31⁄2 11⁄4 81⁄4 4 2.90 1.30 88 32 210 100WSNT127 3⁄4 127 216 5 11⁄2 12 4 5.95 2.70 125 39 300 100WSNT176 1 176 300 5 11⁄2 12 4 5.95 2.70 125 39 300 100WSNT318 11⁄4 318 540 5 11⁄2 12 4 5.95 2.70 125 39 300 100WSNT427 11⁄2 427 725 51⁄2 2 19 6 9.70 4.40 135 50 480 150WSNT675 2 675 1150 51⁄2 2 19 6 9.70 4.40 135 50 480 150WSNT1000 21⁄2 1000 1700 8 23⁄4 24 8 25.5 11.5 200 68 590 200WSNT1500 3 1500 2550 8 23⁄4 24 8 25.5 11.5 200 68 590 200

Page 11: an EnPro Industries company - Michigan Air Solutions · 2017. 1. 1. · an EnPro Industries company STANDARD LINE — SPECIFICATIONS & ENGINEERING DATA Grade 10 1⁄ 4 10 17 Grade

an EnPro Industries company

11

HIGH-PRESSURE

ALUMINUM FILTERS

Coalescer — Absorber

Quincy’s aluminum alloy, 750 psig high pressure filter

lineup offers an economic alternative to the high cost of

stainless steel. There are two levels of coalescing and an

activated carbon absorber. Ideally suited for the PET

bottle blowing industry, the coalescers remove various

levels of liquid aerosols and the activated carbon absorb-

er removes vapor and odors.

• High-temperaturecapacity(250ûF.)

• Multiwrapelementconstructionfor

optimum performance and long life

• Syntheticlubricantandmineraloil

compatibility

• Largesumpandquietzonetoprevent

re-entrainment

• Push-to-fitdesignforeasyfilter

element replacement

• Modulardesignallowsforeasyinstallationof

multiple filters and saves energy

750 psig/250°F150 to 3000 scfm (1/2”to2”NPT)

• HSCTstandardcoalescer

• HPCTpolishingcoalescer

• HACTactivatedcarbon

HIGH-PRESSURE

STAINLESS STEEL FILTERS

Coalescer — Absorber

Quincy’s line of 316 grade Stainless Steel filters

for pressure requirements of 750 psig through

5000 psig feature:

• Three pressure ranges

(750 psig, 1,500 psig, 5,000 psig)

• Heavy-duty,StainlessSteeltierod

design for 1500 psig and 5000 psig

750 psig/250°F

60 to 2000 scfm (1/2”to2”NPT)

• SSCTstandardcoalescer

• SPCTpolishingcoalescer

• SACTactivatedcarbon

1500 psig/250°F

65 to 2050 scfm (1/2”to2”NPT)

• ESCTstandardcoalescer

• EPCTpolishingcoalescer

• EACTactivatedcarbon

5000 psig/250°F28 to 775 scfm (1/2”to11/2”NPT)

• VSCTstandardcoalescer

• VPCTpolishingcoalescer

• VACTactivatedcarbon

Page 12: an EnPro Industries company - Michigan Air Solutions · 2017. 1. 1. · an EnPro Industries company STANDARD LINE — SPECIFICATIONS & ENGINEERING DATA Grade 10 1⁄ 4 10 17 Grade

COMPRESSED AIR F ILTERS

QuincyCompressor.com | Made in the U.S.A. | The Science of Compressed Air 12

HIGH PRESSURE, 750 PSIG — SPECIFICATIONS & ENGINEERING DATA

H__T94 1/4 94 160 H__E94 1 21/2 1/2 6 2 0.5 0.25 63 15 150 50H__T147 3/8 147 250 H__E147 1 21/2 1/2 71/2 2 0.6 0.27 63 15 190 50H__T265 1/2 265 450 H__E265 1 41/2 11/2 12 6 5.7 2.60 114 38 305 150H__T324 3/4 324 550 H__E324 1 41/2 11/2 12 6 5.7 2.60 114 38 305 150H__T492 1 492 835 H__E492 1 41/2 11/2 151/2 6 7.3 3.30 114 38 395 150H__T1015 11/2 1015 1725 H__E1015 1 53/4 2 21 7 16.5 7.50 146 50 435 170H__T1132 2 1132 1925 H__E1132 1 53/4 2 21 7 16.5 7.50 146 50 435 170H__T1882 2 1882 3200 H__E1882 1 53/4 2 25 7 22.0 10.00 146 50 635 170

Metric Element Number Dimensions Dimensions Filter Model Pipe Size Flow Rate Model of A B C D Weight A B C D (Grade) NPT scfm Nm3/hr (Grade) Elements In. In. In. In. lb. kg. mm mm mm mm

Aluminum, 750 psig

S__T60 1/4 60 100 S__E60 1 31/2 3/4 7 3 3.80 1.70 85 18 170 75S__T120 3/8 120 200 S__E120 1 31/2 3/4 8 4 4.40 2.00 85 18 205 100S__T200 1/2 200 340 S__E200 1 31/2 3/4 10 4 4.90 2.20 85 18 255 100S__T300 3/4 300 500 S__E300 1 41/2 11/4 11 6 8.80 4.00 110 27 270 150S__T600 1 600 1000 S__E600 1 41/2 11/4 17 12 11.0 5.00 110 27 420 300S__T1000 11/2 1000 1700 S__E1000 1 6 13/4 21 12 33.0 15.0 150 45 525 300S__T1200 2 1200 2040 S__E1200 1 6 13/4 21 12 33.0 15.0 150 45 525 300S__T2000 2 2000 3400 S__E2000 1 6 13/4 33 20 46.0 21.0 150 45 825 500

Stainless Steel, 750 psig

Models HPAT 94 & 147

Models HPST 60–2000

Models HPAT 265–1882

High-pressure aluminum filter element grades, 750 psigHSCE 1 0.1 0.1 248 120 1.1 75 2.2 150 6 400 750 50 BlackHPCE 0.01 0.01 0.01 248 120 1.5 100 4.4 300 6 400 750 50 BlackHACE 0.01 0.003 0.003 77 25 1.1 75 seenotes 750 50 Black

High-pressure stainless steel filter element grades, 750 psigSSCE 1 0.1 0.1 248 120 1.1 75 2.2 150 10 700 750 50 BlackSPCE 0.01 0.01 0.01 248 120 1.5 100 4.4 300 10 700 750 50 BlackSACE 0.01 0.003 0.003 77 25 1.1 75 seenotes 750 50 Black

Max. Pressure Loss Max. Element Particle Oil Carryover Max. Change Working End CapFilter Removal at 68°F at 20°C Temperature Clean & Dry Wet Element Pressure ColorElement in Microns ppm mg/m3 °F °C psi mbar psi mbar psi mbar psig barg Code

Specs

Operating psig 145 290 435 580 725 Pressure barg 10 20 30 40 50 Correction Factor 0.34 0.57 0.71 0.86 1.0

For maximum flow rate, multiply model flow rate shown in the above table by the correction factor corresponding to the working pressure.

Correction Factor for Aluminum Correction Factor for Stainless Steel

Operating psig 58 87 116 145 220 290 435 580 725 Pressure barg 4 6 8 10 15 20 30 40 50 Correction Factor 0.14 0.22 0.28 0.34 0.47 0.56 0.70 0.85 1.0

Metric Element Number Dimensions Dimensions Filter Model Pipe Size Flow Rate Model of A B C D Weight A B C D (Grade) NPT scfm Nm3/hr (Grade) Elements In. In. In. In. lb. kg. mm mm mm mm

Page 13: an EnPro Industries company - Michigan Air Solutions · 2017. 1. 1. · an EnPro Industries company STANDARD LINE — SPECIFICATIONS & ENGINEERING DATA Grade 10 1⁄ 4 10 17 Grade

an EnPro Industries company

13

HIGH PRESSURE 1500 & 5000 PSIG — SPECIFICATIONS & ENGINEERING DATA

Metric Number Dimensions Dimensions Filter Model Pipe Size Flow Rate Element Model of A B C D Weight A B C D (Grade) NPT scfm Nm3/hr (Grade) Elements In. In. In. In. lb. kg. mm mm mm mm

Stainless Steel, 1500 & 5000 psig

Models HPST 65–775

High-pressure stainless steel filter element grades, 1500 psigESCE 1 0.1 0.1 248 120 1.1 75 2.2 150 6 400 1500 100 BlackEPCE 0.01 0.01 0.01 248 120 1.5 100 4.4 300 6 400 1500 100 BlackEACE 0.01 0.003 0.003 77 25 1.1 75 seenotes 1500 100 Black

High-pressure stainless steel filter element grades, 5000 psigVSCE 1 0.1 0.1 248 120 1.1 75 2.2 150 10 700 5000 350 BlackVPCE 0.01 0.01 0.01 248 120 1.5 100 4.4 300 10 700 5000 350 BlackVACE 0.01 0.003 0.003 77 25 1.1 75 seenotes 5000 350 Black

Max. Pressure Loss Max. Element Particle Oil Carryover Max. Change Working End CapFilter Removal at 68°F at 20°C Temperature Clean & Dry Wet Element Pressure ColorElement in Microns ppm mg/m3 °F °C psi mbar psi mbar psi mbar psig barg Code

Specs

Operating psig 290 435 580 725 870 1015 1160 1300 1500 Pressure barg 20 30 40 50 60 70 80 90 100 Correction Factor 0.45 0.57 0.68 0.80 0.84 0.88 0.92 0.96 1.0

For maximum flow rate, multiply model flow rate shown in the above table by the correction factor corresponding to the working pressure.

Correction Factor for Stainless Steel, 1500 psig

Correction Factor for Stainless Steel, 5000 psig

High-pressure stainless steel filter element grades, 1500 psigE__T65 1/4 65 110 E__E65 1 23/4 3/4 6 3 7.10 3.20 65 20 135 70E__T185 3/8 185 315 E__E185 1 23/4 3/4 10 7 12.3 5.60 65 20 250 180

E__T270 1/2 270 460 E__E270 1 31/2 3/4 11 10 13.5 6.10 88 20 275 250E__T400 3/4 400 680 E__E400 1 51/8 1 11 6 23.2 10.5 132 26 265 150E__T700 1 700 1200 E__E700 1 51/8 1 19 12 32.4 14.7 132 26 480 300E__T1050 11/2 1050 1785 E__E1050 1 6 13/4 21 12 48.5 22.0 150 45 525 300E__T2050 2 2050 3485 E__E2050 1 6 13/4 33 20 61.7 28.0 150 45 825 500

High-pressure stainless steel filter element grades, 5000 psigV__T28 1/4 28 48 V__E28 1 13/4 1/2 4 3 3.50 1.60 41 10 103 60V__T67 3/8 67 111 V__E67 1 23/4 3/4 6 3 7.10 3.20 65 20 135 70 V__T150 1/2 150 255 V__E150 1 31/2 3/4 9 6 12.3 5.60 88 20 210 150V__T310 3/4 310 520 V__E310 1 31/2 1 11 10 13.5 6.10 88 25 280 250V__T445 1 445 750 V__E445 1 6 11/2 13 8 32.0 14.5 150 35 330 200V__T775 11/2 775 1330 V__E775 1 6 11/2 19 12 38.4 17.4 150 35 180 300

Operating psig 725 1450 2175 2900 3625 4350 5000 Pressure barg 50 100 150 200 250 300 350 Correction Factor 0.73 0.78 0.82 0.87 0.91 0.96 1.0

Page 14: an EnPro Industries company - Michigan Air Solutions · 2017. 1. 1. · an EnPro Industries company STANDARD LINE — SPECIFICATIONS & ENGINEERING DATA Grade 10 1⁄ 4 10 17 Grade

MIST ELIMINATOR - HIGH EFFICIENCY

HEAVY-DUTY COALESCING FILTER

• Lowerpressuredropcomparedtocon-ventional coalescing and particulate filters (average1psigversus6psig).Higherpressure drops require the compressor to operate at an elevated pressure, there-forerequiringmorepower.Every2psigreduction in pressure saves approximately 1%aircompressorpowerbasedon100psig operating pressure. Since the Quincy Mist Eliminator does not require prefil-ters or particulate filters, you could easily save in excess of $3,000 per year in air compressor electrical energy (based on 8,000 hours per year operation, $0.07 per Kwhour,100hpcompressoranda93%motor efficiency).

• Largetankvolumecapturesandretainsinadvertent lubricant discharge caused by compressor separation system malfunc-tion,whichprotectsdownstreamequip-ment.

• Average element life of 10 years versus 6 months for conventional coalescing and particulate filter elements reduces main-tenanceandwastedisposal.

The Quincy Mist Eliminator is a heavy-duty

coalescing type filter engineered to efficiently

remove oil, particulate, and water from com-

pressed air. By using a combination of impac-

tion, interception and Brownian Movement, the

Quincy Mist Eliminator achieves 100% effi-

ciency in removing particles 3 micron and larger,

99.98% of 0.1 micron and larger and 99.5% of

0.01 micron and larger. Typical pressure drop

is less than 1 psig. Average element life in con-

tinuous service is 10 years.

A 10-year element life can be achieved in rela-

tively clean environments.

LONG LIFE AND LOW PRESSURE DROP

Calibrated Differential Pressure Gauge is standard equipment

COMPRESSED AIR FILTERS

QuincyCompressor.com | Made in the U.S.A. | The Science of Compressed Air 14

A Pneumatic No-Loss Demand Drain is optional

equipment

Page 15: an EnPro Industries company - Michigan Air Solutions · 2017. 1. 1. · an EnPro Industries company STANDARD LINE — SPECIFICATIONS & ENGINEERING DATA Grade 10 1⁄ 4 10 17 Grade

an EnPro Industries company

15

Compressed air enters the Quincy Mist

Eliminator through the inlet connection on the

top of the tank (see Figure 1) where it is even-

ly distributed throughout the large surface

area of the filter element due to low velocities.

Aerosols and particulate are filtered out and

accumulate in the bottom of the tank, where

they can be removed by an optional Demand

Drain. Clean air then exits through the outlet

connection.

Figure 2

Air in

Air out

Drain

Figure 1

ME — SPECIFICATIONS & ENGINEERING DATA

Mist Eliminator Min. Filter In/Out Dimensions Removal Flanged Drain scfm @ Max Diameter Height Clearance* Approx Connections ConnectionsModel 100 psig psig In. In. In. Wt. lb. In. In.

ME 250S 250 150 14 451/8 22 471 11/2 1 NPTME 500S 500 150 14 581/8 35 518 2 1 NPTME 800S 800 150 14 731/4 50 586 21/2 1 NPTME 1100S 1100 150 16 781/2 551/8 664 3 1 NPTME 1500TP 1500 150 18 697/8 453/8 805 4 1 NPTME 1900TP 1900 150 18 747/8 503/8 965 4 1 NPTME 2500TP 2500 150 18 867/8 623/8 860 5 1 NPTME 3500TP 3500 150 24 8611/16 597/8 1400 5 1 NPTME 4500TP 4500 150 24 993/4 727/8 1517 6 1 NPTME 5000TP 5000 150 24 1053/4 787/8 1564 6 1 NPTME 6000TP 6000 150 24 1207/8 937/8 1726 8 1 NPTME 7000TP 7000 150 30 1083/8 801/8 2450 8 11/2 NPTME 8000TP 8000 150 30 1163/8 881/8 2520 8 11/2 NPTME 9000TP 9000 150 30 1243/8 961/8 2603 8 11/2 NPTME 10000TP 10000 150 36 1183/16 885/8 3640 10 11/2 NPTME 15000TP 15000 150 42 13211/16 1007/8 CF 10 11/2 NPT

Notes:LargerSizesAvailableConsultFactory. *DoesNotIncludeRigging.

1,500 cfm through 15,000 cfm models utilize

a space-saving double element design (see

Figure 2). Using a double nesting tech-

nique, the Quincy Mist Eliminator offers high

efficiency separation in a low profile package.

By nesting an element inside an element, total

surface area is greater than conventional single

element designs. Due to reduced overall height,

the Quincy Mist Eliminator can be installed in

locations where conventional single element

designs cannot. For example, a 10,000 cfm

Quincy Mist Eliminator low profile design

is only 118 inches tall. Compare this to other

single element designs that are 210 inches tall.

That’s a reduction of over 7 feet in overall

height! Imagine the savings in time and con-

venience when you change the element or

service the unit.

All Quincy Mist Eliminator tanks are ASME

coded and stamped. Standard equipment

includes a calibrated differential pressure

gauge and enamel paint. No Loss Demand

Drains are optional. Pressure relief valves are

not included but may be required by local

codes.

HOW THE QUINCY MIST ELIMINATOR WORKS

UNIQUE DOUBLE ELEMENT DESIGN

Page 16: an EnPro Industries company - Michigan Air Solutions · 2017. 1. 1. · an EnPro Industries company STANDARD LINE — SPECIFICATIONS & ENGINEERING DATA Grade 10 1⁄ 4 10 17 Grade

quincycompressor.com

QPNC-500quincycompressor.com

QDHT-1000quincycompressor.com

Air Quality ClassificationISO 8573.1

WSNBulk

LiquidDP1

Quincy Rotary Screw Wet Receiver

1gal/CFMand/or

MistEliminator

DP2

Dry Receiver

5gal/CFM

CSN1 Micron0.1 PPM

DP3

CPN0.01 Micron0.01 PPM

DP5ACN

0.003 PPMVapor & Odors

SolidsMicron ISO PDP ISO PPM ISO

0.01 1 +38˚F 4 0.01 1 10.7 738

0.01 1 +38˚F 4 0.003 1 11.8 814

1 2 -40˚F 2 0.01 1 9.2 634

0.01 1 -40˚F 2 0.003 1 10.3 710

1 2 +50˚F 6 0.01 2 7.8 538

0.01 1 +50˚F 6 0.003 1 10.0 689

1 2 -40˚F 2 0.01 1 9.2 634

0.01 1 -100˚F 1 0.001 1 14.2 979

Moisture Oilpsi Mbar

Refrigerated Air DryerQPNC Non-Cycling

QPCD CyclingDP4

WetSystemAvg. DP

Quincy Reciprocating AC

WSN Moisture Separator

DCN Particulate/Coarse Coalescer

CSN STD 0.1 PPM Coalescer, 1 Micron

CPN Polishing 0.01 PPM Coalescer

CXN Xtra 0.001 PPM Coalescer

ACN Activated Carbon Absorber

OUD Over + Under Duplex

HTD High Temperature, 1 Micron

QPNC Non-Cycling Refrigerated Dryer

QPCD Cycling Refrigerated Dryer

QDTS Small Heatless Dryer

QDTH Industrial Heatless Dryer

QDHP Heated Purge Dryer

QDBP Blower Purge Dryer

QPHT High Temp. Refrigerated Dryer

AC After Cooler

DP Drain Point

WSNBulk

LiquidDP6

Dry Receiver

5gal/CFM

CPN0.01 Micron0.01 PPM

DP7

CSN (NPT)HTD (FLG)1 Micron

Particulate

ACN0.003 PPMVapor & Odors

0.01 1 -40˚F 2 0.003 1 10.3 710

ACN0.003 PPMVapor & Odors

Desiccant Heatless Air DryerQDTS—Small

QDTH—Industrial-40˚F PDP

QuincyCondensate

Purifier

CSN1 Micron0.1 PPM

DP11 CPN0.01 Micron0.01 PPM

ACN0.003 Micron

OUD

High Temperature/Refrigerated Air DryerQPHT—High Temp.

DP10

Dry Receiver

5gal/CFM

CPN0.01 Micron0.01 PPM

DP8

Desiccant Heated Air DryerQDHP—Heated PurgeQDBP—Blower Purge

-40˚F PDP

QDHP-1000quincycompressor.com

Approximate Liquid Removal100 CFM, 100 psi, 80˚F, 4000 hrs./yr., 2 PPM

DrainPoint

1234

300020003051300

Gallonsper Year

DrainPoint

5678

1403000310310

Gallonsper Year

DrainPoint

91011

3004320120

Gallonsper Year

QPHT-40quincycompressor.com

NOTE: Requires CXN (.001 PPM) filter in series with standard CPN prefilter.

CSN1 Micron

Particulate

QSI-500iquincycompressor.com

DCN5 Micron5 PPMDP9

an EnPro Industries company

an EnPro Industries company

701 North Dobson Avenue | Bay Minette, AL 36507 | Phone 251.937.5900 | Fax 251.937.7182 | Email: [email protected]

©2009 Quincy Compressor an EnPro Industries company All rights reserved. Printed in U.S.A. (QATF-004 03/09)

COMPRESSED AIR SYSTEMS BEST PRACTICE