An Introduction to RAC System Test Planning Methods
Ajith NarayananERP Advisor , Dell IT
Bangalore, 29th June 2013
Ajith Narayanan
ERP Advisor
Dell IT
� 8.5 years of Oracle Apps & Oracle DBA experience.
� Blogger :- http://oracledbascriptsfromajith.blogspot.com
� Website Chair:- http://www.oracleracsig.org – Oracle RAC SIG
Who Am I?
Agenda
� Real Application Clusters Testing Objectives
� Oracle Technologies Used For Tests
� Test 1 :Planned Node Reboot
� Test 2 :Clusterware and Fencing
� Test 3 :Restart Failed Node
� Test 4 :Reboot All Nodes Same Time
� Test 5 :Unplanned Instance Failure
� Test 6 :Planned Instance Termination
� Test 7 :Clusterware and Fencing
� Test 8: Service Failover
� Test 9: Public Network Failure
� Test 10: Interconnect Network Failure
� Sample Cluster Callout Script
� Q & A
Real Application Clusters Testing Objectives
� To verify that the system has been installed and configured correctly. Check that nothing is in broken state.
� To Verify that basic functionality still works in a specific environment and for a specific workload.
� To make sure that the system will achieve its objectives, in particular, availability and performance objectives.
Oracle Technologies Used For Tests
� Fast Application Notification (FAN) – Notification mechanism that alerts application of service level changes of the database.
� Fast Connection Failover (FCF) – Utilizes FAN events to enable database clients to proactively react to down events by quickly failing over connections to surviving database instances.
� Transparent Application Failover (TAF) – Allows for connections to be automatically reestablished to a surviving database instance in the case that the instance servicing the initial connection should fail. TAF has the ability to fail over in-flight select statements (if configured) but insert, update and delete transactions will be rolled back.
� Runtime Connection Load Balancing (RCLB) – Provides intelligence about the current service level of the database instances to application connection pools. This increases the performance of the application by utilizing least loaded servers to service application requests and allows for dynamic workload balancing in the event of the loss of service by a database instance or increase of service by adding a database instance.
Test 1 :Planned Node Reboot
Procedure� Start client workload & Identify instance with most client connections � Reboot the node where the most loaded instance is running � For AIX, HPUX, Windows: “shutdown –r” , For Linux: “shutdown –r now” , For Solaris: “reboot”
Expected Results � The instances and other Clusterware resources go offline ( ‘SERVER’ field of crsctl stat res –t output) � The node VIP fails over the surviving nodes and will show a state of “INTERMEDIATE” with state_details of
“FAILED_OVER” � The SCAN VIP(s) that were running on the rebooted node will fail over to surviving nodes. � The SCAN Listener(s) running on that node will fail over to a surviving node. � Instance recovery is performed by another instance. � Services are moved to available instances� Client connections are moved / reconnected to surviving instances (Procedure and timings will depend on client types
and configuration). With TAF configured select statements should continue. Active DMLwill be aborted. � After the database reconfiguration, surviving instances continue processing their workload.
Measures � Time to detect node or instance failure. Time to complete instance recovery. Alert Log helps� Time to restore client activity to same level.� Time before failed instance is restarted automatically by Clusterware and is accepting new connections � Successful failover of the SCAN VIP(s) and SCAN Listener(s)
Procedure� Start client workload.
� Identify the node that is the OCR master using the following grep command from any of the nodes:
� grep -i "OCR MASTER" $GI_HOME/log/<node_name>/crsd/crsd.l*
NOTE: Windows users must manually review the $GI_HOME/log/<node_name>/crsd/crsd.l* logs to determine the OCR Master.
� Power off the node that is the OCR master.
NOTE: On many servers the power-off switch will perform a controlled shutdown, So we have to cut the power supply .
Expected Results � The instances and other Clusterware resources go offline ( ‘SERVER’ field of crsctl stat res –t output) � The node VIP fails over the surviving nodes and will show a state of “INTERMEDIATE” with state_details of
“FAILED_OVER” � The SCAN VIP(s) that were running on the rebooted node will fail over to surviving nodes. � The SCAN Listener(s) running on that node will fail over to a surviving node. � Instance recovery is performed by another instance. � Services are moved to available instances
� Client connections are moved / reconnected to surviving instances (Procedure and timings will depend on client types and configuration). With TAF configured select statements should continue. Active DMLwill be aborted.
� After the database reconfiguration, surviving instances continue processing their workload.
Test 2 :Unplanned Node Failure Of OCR Master
Procedure� ajithpathiyil2:/home/oracle[RAC1]$ srvctl start instance –d RAC –I RAC1
Expected Results� On clusters having 3 or fewer nodes, one of the SCAN VIPs and Listeners will be relocated to the restarted node when
the Oracle Clusterware starts.
� The VIP will migrate back to the restarted node.
� Services that had failed over as a result of the node failure will NOT automatically be relocated.
� Failed resources (asm, listener, instance, etc) will be restarted by the Clusterware.
Measures� Time for all resources to become available again, Check with “crsctl stat res –t”
Test 3 :Restart Failed Node
Procedure� Issue a reboot on all nodes at the same time
� For AIX, HPUX, Windows: ‘shutdown –r’
� For Linux: ‘shutdown –r now’
� For Solaris: ‘reboot’
Expected Results� All nodes, instances and resources are restarted without problems
Measures� Time for all resources to become available again, Check with “crsctl stat res –t”
Test 4 :Reboot All Nodes Same Time
Procedure
� Start client workload � Identify single database instance with the most client connections and abnormally terminate that instance:
For AIX, HPUX, Linux, Solaris:
Obtain the PID for the pmon process of the database instance: # ps –ef | grep pmonkill the pmon process: # kill –9 <pmon pid>
For Windows:
Obtain the thread ID of the pmon thread of the database instance by running: SQL> select b.name, p.spid from v$bgprocess b, v$process p where b.paddr=p.addr and b.name=’PMON’; Run orakill to kill the thread: cmd> orakill <SID> <Thread ID>
Test 5 :Unplanned Instance Failure
Expected Results� One of the other instances performs instance recovery
� Services are moved to available instances, if a preferred instance failed
� Client connections are moved / reconnected to surviving instances (Procedure and timings will depend on client types and configuration)
� After a short freeze, surviving instances continue processing the workload
� Failing instance will be restarted by Oracle Clusterware, unless this feature has been disabled
Measures� Time to detect instance failure
� Time to complete instance recovery. Check alert log for recovering instance
� Time to restore client activity to same level (assuming remaining nodes have sufficient capacity to run workload)
� Duration of database freeze during failover.
� Time before failed instance is restarted automatically by Oracle Clusterware and is accepting new connections
Test 5 :Unplanned Instance Failure
Procedure
� Issue a ‘shutdown abort’
Expected Results
� One other instance performs instance recovery � Services are moved to available instances, if a preferred instance failed � Client connections are moved / reconnected to surviving instances (Procedure and timings will depend on client
types and configuration) � The instance will NOT be automatically restarted by Oracle Clusterware due to the user invoked shutdown.
Measures
� Time to detect instance failure. � Time to complete instance recovery. Check alert log for recovering instance. � Time to restore client activity to same level (assuming remaining nodes have sufficient capacity to run workload). � The instance will NOT be restarted by Oracle Clusterware due to the user induced shutdown.
Test 6 :Planned Instance Termination
Test 7 : Clusterware and Fencing
Node fencing is a general concept used by computer clusters to forcefully remove a malfunctioning node from it. This preventive technique is a necessary measure to make sure no I/O from malfunctioning node can be done, thus preventing data corruptions and guaranteeing cluster integrity.
Procedure1. Start with a normal, running cluster with the database instances up and running.2. Monitor the logfiles for clusterware on each node. On each node, start a new window and run thefollowing command:
The network heartbeats are associated with a timeout called misscount, set from 11g Release 1 to 30.
ajithpathiyil1:/home/oracle[+ASM1] $crsctl get css misscount30
ajithpathiyil1:/home/oracle[+ASM1] $oifcfg getifbond0 192.168.78.51 global public bond1 10.10.0.0 global cluster_interconnect
ajithpathiyil1:/home/oracle[grid]$ tail -f /u01/grid/oracle/product/11.2.0/grid_1/log/ajithpathiyil2/crsd/crsd.l*ajithpathiyil1:/home/oracle[grid]$ tail -f /u01/grid/oracle/product/11.2.0/grid_1/log/‘hostname -s‘/cssd/ocssd.logajithpathiyil2:/home/oracle[grid]$ ifconfig eth1 down
Test 7 : Clusterware and Fencing
Expected Results� Following this command, watch the logfiles you began monitoring in step 2 above. You should see errors in those
logfiles and eventually (could take a minute or two, literally) you will observe one node reboot itself.
� If you used ifconfig to trigger a failure, then the node will rejoin the cluster and the instance should start automatically.
Alert Log[cssd(2864)]CRS-1612:Network communication with node rac1 (1) missing for 50% of timeout interval. Removal of this node from cluster in 14.920 seconds… [cssd(2864)]CRS-1610:Network communication with node rac1 (1) missing for 90% of timeout interval. Removal of this node from cluster in 2.900 seconds [cssd(2864)]CRS-1609:This node is unable to communicate with other nodes in the cluster and is going down to p reserve cluster integrity
More debugging information is written to the ocssd.bin process log file: [CSSD][1119164736](:CSSNM00008:)clssnmCheckDskInfo: Aborting local node to avoid splitbrain. Cohort of 1 nodes with leader 2, rac2, is smaller than cohort of 1 nodes led by node 1, rac1, based onmap type 2 [CSSD][1119164736]################################### [CSSD][1119164736]clssscExit: CSSD aborting from thread clssnmRcfgMgrThread[CSSD][1119164736]###################################
Test 8: Service Failover
Procedure� Create a Service
ajithpathiyil2:/home/oracle[RAC1]$ srvctl add service -d RAC -s svctest -r RAC1 -a RAC2 -P BASIC
ajithpathiyil2:/home/oracle[RAC1]$ srvctl start service -d RAC -s svctest
ajithpathiyil2:/home/oracle[RAC1]$ srvctl status service -d RAC -s svctest
Service svctest is running on instance(s) RAC1
ajithpathiyil2:/home/oracle[RAC1]$
Warning !
� You should never directly change the SERVICE_NAMES init parameter on a RAC database!! This parameter is maintained automatically by the clusterware.
SQL> show user
USER is "SYS"
SQL> select instance_name from v$instance;
INSTANCE_NAME
----------------
RAC1
SQL> shutdown abort;
ORACLE instance shut down.
SQL>
Procedure
� Unplug all network cables for the public network
NOTE: It is recommended NOT to use ifconfig to down the interface, this may lead to the address still being plumbed to the interface resulting in unexpected results.
Expected Results
•Check with “crsctl stat res –t”
� The ora.*.network and listener resources will go offline for the node. � SCAN VIPs and SCAN LISTENERs running on the node will fail over to a surviving node.
ajithpathiyil2:/home/oracle[grid]$ srvctl status scanSCAN VIP scan1 is enabledSCAN VIP scan1 is running on node ajithpathiyil2ajithpathiyil2:/home/oracle[grid]$
ajithpathiyil2:/home/oracle[grid]$ srvctl status scan_listenerSCAN Listener LISTENER_SCAN1 is enabledSCAN listener LISTENER_SCAN1 is running on node ajithpathiyil2ajithpathiyil2:/home/oracle[grid]$
Test 9: Public Network Failure
� The VIP for the node will fail over to a surviving node.
� The database instance will remain up but will be unregistered with the remote listeners.
� Database services will fail over to one of the other available nodes.
� If TAF is configured, clients should fail over to an available instance.
NODE VERSION=1.0 host=ajithpathiyil2 incarn=0 status=nodedown reason=public_nw_down timestamp=30-Aug-2009 01:56:12 reported=Sun Jan 30 01:56:13 CDT 2013
NODE VERSION=1.0 host=ajithpahtiyil2 incarn=147028525 status=nodedown reason=member_leave timestamp=30-Aug-2009 01:57:19 reported=Sun Aug 30 01:57:20 CDT 2013
Measures� Time to detect the network failure and relocate resources.
Test 9: Public Network Failure
Procedure
� Unplug all network cables for the interconnect network
NOTE: It is recommended NOT to use ifconfig to down the interface, this may lead to the address still being plumbed to the interface resulting in unexpected results.
Expected ResultsFor 11.2.0.2 and above:
� CSSD will detect split-brain situation and perform one of the following:
� o In a two-node cluster the node with the lowest node number will survive. � o In a multiple node cluster the largest sub-cluster will survive.
� On the node(s) that is being evicted, a graceful shutdown of Oracle Clusterware will be attempted. o All I/O capable client processes will be terminated and all resources will be cleaned up. If process termination and/or resource cleanup does not complete successfully the node will be rebooted.
� o Assuming that the above has completed successfully, OHASD will attempt to restart the stack. In this case the stack will be restarted once the network connectivity of the private interconnect network has been restored.
� Review the following logs: o $GI_HOME/log/<nodename>/alert<nodename>.log o $GI_HOME/log/<nodename>/cssd/ocssd.log
Test 10: Interconnect Network Failure
Measures
� For 11.2.0.2 and above:
� Oracle Clusterware will gracefully shutdown, should graceful shutdown fail (due to I/O processes not being terminated or resource cleanup) the node will be rebooted.
� Assuming that the graceful shutdown of Oracle Clusterware succeeded, OHASD will restart the stack once network connectivity for the private interconnect has been restored.
Test 10: Interconnect Network Failure
Sample Cluster Callout Script
#!/bin/ksh
# # Author: Ajith Narayanan
## http://oracledbascriptsfromajith.blogspot.com
## Version 1.0
## This callout script is extended to report/mail the affected weblogic services when any Oracle cluster event occurs.
##
umask 022
FAN_LOGFILE=$ORACLE_HOME/racg/usrco/`hostname`_uptime.log
EVENTLINE=$ORACLE_HOME/racg/usrco/`hostname`_eventline.log
EVENTLINE_MID=$ORACLE_HOME/racg/usrco/`hostname`_eventline_mid.log
MAIL_CONT=$ORACLE_HOME/racg/usrco/`hostname`_mail.log
WEBLOGIC_DS=$ORACLE_HOME/racg/usrco/weblogic_ds
echo $* "reported="`date` >> $FAN_LOGFILE &
tail -1 $FAN_LOGFILE > $EVENTLINE
awk '{
for (f = 1; f <= NF; f++) { a[NR, f] = $f } } NF > nf { nf = NF } END {
for (f = 1; f <= nf; f++) { for (r = 1; r <= NR; r++) { printf a[r, f] (r==NR ? RS : FS) } }
}' $EVENTLINE > $EVENTLINE_MID
SER=`grep "service=" $EVENTLINE_MID|awk -F= '{print $2}'`
DB=`grep "database=" $EVENTLINE_MID|awk -F= '{print $2}'`
INST=`grep "instance=" $EVENTLINE_MID|awk -F= '{print $2}'`
HOST=`grep "host=" $EVENTLINE_MID|awk -F= '{print $2}'`
STAT=`grep "status=" $EVENTLINE_MID|awk -F= '{print $2}'`
if [ "$SER" != " " | "$DB" != " " | "$INST" != " " | "$HOST" != " " | "$STAT" != " " ]; then
if [ $STAT = nodedown ]; then
cat $EVENTLINE_MID > $MAIL_CONT
echo "**============================SERVICES AFFECTED===============================**" >> $MAIL_CONT
grep -i "$DB_" $WEBLOGIC_DS >> $MAIL_CONT
elif [ $STAT = up ]; then
cat $EVENTLINE_MID > $MAIL_CONT
echo "**============================SERVICES RESTORED===============================**" >> $MAIL_CONT
grep -i "$DB_" $WEBLOGIC_DS|grep "SERVICE_NAME=$SER" >> $MAIL_CONT
else
cat $EVENTLINE_MID > $MAIL_CONT
echo "**============================SERVICES AFFECTED===============================**" >> $MAIL_CONT
grep -i "$DB_" $WEBLOGIC_DS|grep "SERVICE_NAME=$SER" >> $MAIL_CONT
#fi
cat $MAIL_CONT| /bin/mail -s "Cluster $STAT event: $DB $INST $SER $HOST" [email protected]
fi
#cat $MAIL_CONT| /bin/mail -s "Cluster $STAT event: $DB $INST $SER $HOST" [email protected]
fi
rm $EVENTLINE $EVENTLINE_MID $MAIL_CONT
Sample Cluster Callout Script
Q & A