analysis of ims data
DESCRIPTION
Analysis of IMS Data. By Ed Sittler CAPS Team Meeting #28 Marseille, France July 26-28, 2004. Analysis of TOF Data. Purpose: Determine ion composition Revise calibration parameters for FM Peak shifts Peak Amplitudes and widths Algorithm - PowerPoint PPT PresentationTRANSCRIPT
![Page 1: Analysis of IMS Data](https://reader034.vdocuments.net/reader034/viewer/2022051117/568159a4550346895dc6fe92/html5/thumbnails/1.jpg)
Analysis of IMS Data
By Ed Sittler
CAPS Team Meeting #28
Marseille, France
July 26-28, 2004
![Page 2: Analysis of IMS Data](https://reader034.vdocuments.net/reader034/viewer/2022051117/568159a4550346895dc6fe92/html5/thumbnails/2.jpg)
Analysis of TOF Data• Purpose:
– Determine ion composition
– Revise calibration parameters for FM
• Peak shifts
• Peak Amplitudes and widths
• Algorithm
– Read routine which sums bcycle data in 2D arrays for ST & LEF.
• Use highest data rate modes (I.e., 4, 8, 16 kbps).
• Set start and stop times.
• Store data in file.
– Read file from previous step.
• Make 2D color spectrograms.
• Make line plots of TOF data for specific estep.
– Perform non-linear least-squares fit to TOF data.• Can do up to 10 ions. Use line profile parameters as given. Only adjust ion counts.
• Presently we can shift the ion peaks manually. We also fit simultaneously to the background.
• First do manual fit.
• Then do non-linear fit. Compute chisqr.
• Plot Results.
• Further generalizations being considered.
![Page 3: Analysis of IMS Data](https://reader034.vdocuments.net/reader034/viewer/2022051117/568159a4550346895dc6fe92/html5/thumbnails/3.jpg)
![Page 4: Analysis of IMS Data](https://reader034.vdocuments.net/reader034/viewer/2022051117/568159a4550346895dc6fe92/html5/thumbnails/4.jpg)
![Page 5: Analysis of IMS Data](https://reader034.vdocuments.net/reader034/viewer/2022051117/568159a4550346895dc6fe92/html5/thumbnails/5.jpg)
![Page 6: Analysis of IMS Data](https://reader034.vdocuments.net/reader034/viewer/2022051117/568159a4550346895dc6fe92/html5/thumbnails/6.jpg)
![Page 7: Analysis of IMS Data](https://reader034.vdocuments.net/reader034/viewer/2022051117/568159a4550346895dc6fe92/html5/thumbnails/7.jpg)
![Page 8: Analysis of IMS Data](https://reader034.vdocuments.net/reader034/viewer/2022051117/568159a4550346895dc6fe92/html5/thumbnails/8.jpg)
![Page 9: Analysis of IMS Data](https://reader034.vdocuments.net/reader034/viewer/2022051117/568159a4550346895dc6fe92/html5/thumbnails/9.jpg)
![Page 10: Analysis of IMS Data](https://reader034.vdocuments.net/reader034/viewer/2022051117/568159a4550346895dc6fe92/html5/thumbnails/10.jpg)
![Page 11: Analysis of IMS Data](https://reader034.vdocuments.net/reader034/viewer/2022051117/568159a4550346895dc6fe92/html5/thumbnails/11.jpg)
![Page 12: Analysis of IMS Data](https://reader034.vdocuments.net/reader034/viewer/2022051117/568159a4550346895dc6fe92/html5/thumbnails/12.jpg)
![Page 13: Analysis of IMS Data](https://reader034.vdocuments.net/reader034/viewer/2022051117/568159a4550346895dc6fe92/html5/thumbnails/13.jpg)
ST TOF Spectrum 182(23:24) No Shift
![Page 14: Analysis of IMS Data](https://reader034.vdocuments.net/reader034/viewer/2022051117/568159a4550346895dc6fe92/html5/thumbnails/14.jpg)
ST TOF Spectrum 182(23:24) Shifted
![Page 15: Analysis of IMS Data](https://reader034.vdocuments.net/reader034/viewer/2022051117/568159a4550346895dc6fe92/html5/thumbnails/15.jpg)
LEF TOF Spectrum 182(23:24)
![Page 16: Analysis of IMS Data](https://reader034.vdocuments.net/reader034/viewer/2022051117/568159a4550346895dc6fe92/html5/thumbnails/16.jpg)
ST TOF Spectrum 182(18:24) No Shift
![Page 17: Analysis of IMS Data](https://reader034.vdocuments.net/reader034/viewer/2022051117/568159a4550346895dc6fe92/html5/thumbnails/17.jpg)
ST TOF Spectrum 182(18:24) Shifted
![Page 18: Analysis of IMS Data](https://reader034.vdocuments.net/reader034/viewer/2022051117/568159a4550346895dc6fe92/html5/thumbnails/18.jpg)
LEF TOF Spectrum 182(18:24)
![Page 19: Analysis of IMS Data](https://reader034.vdocuments.net/reader034/viewer/2022051117/568159a4550346895dc6fe92/html5/thumbnails/19.jpg)
ST TOF Spectrum 182(18:24) E = 30 eV
![Page 20: Analysis of IMS Data](https://reader034.vdocuments.net/reader034/viewer/2022051117/568159a4550346895dc6fe92/html5/thumbnails/20.jpg)
LEF TOF Spectrum 182(18:24) E = 30 eV
![Page 21: Analysis of IMS Data](https://reader034.vdocuments.net/reader034/viewer/2022051117/568159a4550346895dc6fe92/html5/thumbnails/21.jpg)
Summary of TOF Analysis Results
• Composition of H+, N+, Water Group Ions & O2+. Detection of H2+ ?
• Shift ~ 16 channels (2048) seems to be required.• With no shift H3O+ tends to dominate, C+ more important and N+ less
important.• With shift H2O+ tends to dominate, N+ more important and C+ less
important.• LEF data shows H+, N+ and Water Group Ions. No C+ seen. O2
+ can produce peak near N+ peak, but to shorter TOF. Therefore, less favored by data. Although O2
+ is present it is not sufficiently intense.• LEF data set ideal for detection of N+ since O+ has low sensitivity in
LEF data (I.e., O+ tends to want electrons).• ST O- peak shoulder to lower TOF not understood.• Electronic peaks? Remove bad data (I.e., revise script pgm).
![Page 22: Analysis of IMS Data](https://reader034.vdocuments.net/reader034/viewer/2022051117/568159a4550346895dc6fe92/html5/thumbnails/22.jpg)
Analysis of Ion Data
• Purpose:– Determine ion composition.– Determine distribution functions of individual ion species.– Compute ion moments.– Study performance of SAM algorithm and Group Tables.– Incorporate revised FM cal parameters into ion analysis. Reconstruct ion counts
from data. Required high rate data (4, 8 and 16 kbps)
• Procedure– Read level0 data products for period 182(18:24). Sum data for various ion species
as function of estep and angular sector.– Study statistical properties and search for systematic effects as function of estep and
angular sector.– Plot data in appropriate format.– Apply non-linear fitting algorithm which uses revised FM cal data derived from
analysis of TOF data. Reconstruct true ion counts for all ion species. Manually, we have already been doing this.
![Page 23: Analysis of IMS Data](https://reader034.vdocuments.net/reader034/viewer/2022051117/568159a4550346895dc6fe92/html5/thumbnails/23.jpg)
![Page 24: Analysis of IMS Data](https://reader034.vdocuments.net/reader034/viewer/2022051117/568159a4550346895dc6fe92/html5/thumbnails/24.jpg)
![Page 25: Analysis of IMS Data](https://reader034.vdocuments.net/reader034/viewer/2022051117/568159a4550346895dc6fe92/html5/thumbnails/25.jpg)
![Page 26: Analysis of IMS Data](https://reader034.vdocuments.net/reader034/viewer/2022051117/568159a4550346895dc6fe92/html5/thumbnails/26.jpg)
![Page 27: Analysis of IMS Data](https://reader034.vdocuments.net/reader034/viewer/2022051117/568159a4550346895dc6fe92/html5/thumbnails/27.jpg)
![Page 28: Analysis of IMS Data](https://reader034.vdocuments.net/reader034/viewer/2022051117/568159a4550346895dc6fe92/html5/thumbnails/28.jpg)
![Page 29: Analysis of IMS Data](https://reader034.vdocuments.net/reader034/viewer/2022051117/568159a4550346895dc6fe92/html5/thumbnails/29.jpg)
![Page 30: Analysis of IMS Data](https://reader034.vdocuments.net/reader034/viewer/2022051117/568159a4550346895dc6fe92/html5/thumbnails/30.jpg)
![Page 31: Analysis of IMS Data](https://reader034.vdocuments.net/reader034/viewer/2022051117/568159a4550346895dc6fe92/html5/thumbnails/31.jpg)
![Page 32: Analysis of IMS Data](https://reader034.vdocuments.net/reader034/viewer/2022051117/568159a4550346895dc6fe92/html5/thumbnails/32.jpg)
Summary of Ion Data Analysis• Overall ion data looks good.
– But, RTIU problem, especially within inner magnetosphere caused us to throw away a lot of the data. Script program helped but then bad data leaked into results. Localized spikes in data. Needs further work.
• Definite anti-correlations with estep between OH+ & H2O+
– Interpolation between esteps may cause systematic effects.– If there were no systematic effects than anti-correlations would go away
by summing over many spectra.– Adding nearby esteps may remove some of the problem.– Going to hardware binning should definitely fix the problem.
• Summing water group ions together removes anti-correlations. This was expected.
• Signal peaks in sector 2 as expected. Enhancement in sector 8 indicated pressure anisotropy effect?
• We will next need to apply non-linear fitting algorithm to reconstruct ion counts. Here, we would use revised FM cal parameters from analysis of TOF data.