angle resolved photoemission spectroscopy€¦ · angle resolved photoemission spectroscopy. low...

44
Angle Resolved Photoemission Spectroscopy Dan Dessau University of Colorado, Boulder [email protected]

Upload: dongoc

Post on 03-Jul-2018

241 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Angle Resolved Photoemission Spectroscopy€¦ · Angle resolved photoemission spectroscopy. Low energy excitation ... Initial state occupied band k ... Cooper Pair -k k Conventional

Angle Resolved Photoemission Spectroscopy

Dan DessauUniversity of Colorado, Boulder

[email protected]

Page 2: Angle Resolved Photoemission Spectroscopy€¦ · Angle resolved photoemission spectroscopy. Low energy excitation ... Initial state occupied band k ... Cooper Pair -k k Conventional

sample

analyzer

e -

Photoemission Spectroscopy

Density of States

Ene

rgy

EFe-

Primary electrons – no scattering events. Contain information of density of states

Secondary electrons (inelastic background) – increases with decreasing kinetic energy.

High K.E. Low B.E.

Low K.E. High B.E.

Page 3: Angle Resolved Photoemission Spectroscopy€¦ · Angle resolved photoemission spectroscopy. Low energy excitation ... Initial state occupied band k ... Cooper Pair -k k Conventional

Three Step Model W.E. Spicer

Page 4: Angle Resolved Photoemission Spectroscopy€¦ · Angle resolved photoemission spectroscopy. Low energy excitation ... Initial state occupied band k ... Cooper Pair -k k Conventional

• Angle–dependent core level spectroscopy (not this talk)• To vary the surface sensitivity of an experiment

•normal emission – more bulk sensitive•glancing emission – more surface sensitive

• To perform X-ray photoelectron Diffraction (XPD)•Obtain local structural information (similar to EXAFS)

•Angle-dependent valence band spectroscopy (this talk)• To measure the k (momentum) dependence of valence band states• To measure electronic band dispersions and Fermi Surfaces• To measure symmetries of states• To obtain many-body phenomena (e.g. correlated electron systems).

Angle resolved photoemission spectroscopy

Page 5: Angle Resolved Photoemission Spectroscopy€¦ · Angle resolved photoemission spectroscopy. Low energy excitation ... Initial state occupied band k ... Cooper Pair -k k Conventional

Low energy excitation

Energy (E) and momentum (p or k) are the most important quantum numbers in a solid. Specifying these specifies behavior of electrons.

Quantum numbers E,k

Newton : KE=0.5 mv2 = p2/2m p=mv, p=hk

-1.0 -0.5 0.0 0.5 1.0

KE

p

-1.0 -0.5 0.0 0.5 1.0

E

k

EF

kF-kF

Pauli Principle - each electron goes into it’s own individual quantum state (new E,k). Fill lowest energy states first. Highest energy electrons are at Fermi Energy EF, with a momentum hkF. These are the most important electrons. All low energy excitations come from near EF.

kx

ky

occupied

unoccupied

Fermi Surface

Brillouin Zone

Page 6: Angle Resolved Photoemission Spectroscopy€¦ · Angle resolved photoemission spectroscopy. Low energy excitation ... Initial state occupied band k ... Cooper Pair -k k Conventional

Electrons in a periodic potential

a

KE

kp/a-p/a

G=2p/a

Band Structure calculation of Bi2Sr2CaCu2O8 (Bi2212).

S. Massidda et al, Physica C 152, 251 (1988)

Ene

rgy

(eV

)

Everything still mean-field or static - no correlation effects yet.

Page 7: Angle Resolved Photoemission Spectroscopy€¦ · Angle resolved photoemission spectroscopy. Low energy excitation ... Initial state occupied band k ... Cooper Pair -k k Conventional

Metals and Insulators

p/a

E

k-p/aEF

Solid H (metal)

p/a

E

k-p/a

EFSolid He (insulator)

Band theory: EF in a band --> Metal. EF in a gap between bands --> insulator

1s band

2s band

Costs Energy U

Metal

Insulator

Mott Insulators - Failure of this model

Effects most important in localized (d- and f-electron systems).==> High Tc superconductors, Colossal Magnetoresistive oxides, etc.

U=-ke2/r

U

DOS

E

W

UpperHubbardBand

LowerHubbardBand

EF

Page 8: Angle Resolved Photoemission Spectroscopy€¦ · Angle resolved photoemission spectroscopy. Low energy excitation ... Initial state occupied band k ... Cooper Pair -k k Conventional

θφ

A detector

sample

e-

Angle Resolved Photoemission (ARPES)Angle Resolved Photoemission (ARPES)A momentum resolved spectroscopyA momentum resolved spectroscopy

Electron momentum Parallel to the surface is conserved

)(),( Intensity2

EfEAifi,f

kAprrr∑ •∝

Most direct way to measure E vs. k of a solid.

Page 9: Angle Resolved Photoemission Spectroscopy€¦ · Angle resolved photoemission spectroscopy. Low energy excitation ... Initial state occupied band k ... Cooper Pair -k k Conventional

Photons of a few hundred eV or less carry negligible momentum compared to the typical electron momentum scales in a solid.

Therefore we consider “vertical” transition processes. For a free electron parabola there would be no final state and the process is forbidden.

E

k

EF

E

k

EF

G=2π/a

The vertical transition is allowed by considering the extended zone scheme and employing a reciprocal lattice vector G=2π/a (the lattice degree of freedom takes care of the “missing” momentum).

Page 10: Angle Resolved Photoemission Spectroscopy€¦ · Angle resolved photoemission spectroscopy. Low energy excitation ... Initial state occupied band k ... Cooper Pair -k k Conventional
Page 11: Angle Resolved Photoemission Spectroscopy€¦ · Angle resolved photoemission spectroscopy. Low energy excitation ... Initial state occupied band k ... Cooper Pair -k k Conventional
Page 12: Angle Resolved Photoemission Spectroscopy€¦ · Angle resolved photoemission spectroscopy. Low energy excitation ... Initial state occupied band k ... Cooper Pair -k k Conventional

Angular defining aperture

sampleElectron flight paths

Hemispherical electron detector

Mapping of angle to position.

Electron lens

Hemispherical electron detector

Conventional mode of performing ARPES

Angle-mode in modern ARPES analyzers

XYhn

Page 13: Angle Resolved Photoemission Spectroscopy€¦ · Angle resolved photoemission spectroscopy. Low energy excitation ... Initial state occupied band k ... Cooper Pair -k k Conventional

•UHV analysis chamber (10-11 Torr)

•5 axis, He cooled sample manipulator

•Load-Lock transfer system

•Samples may be cleaved in UHV

Page 14: Angle Resolved Photoemission Spectroscopy€¦ · Angle resolved photoemission spectroscopy. Low energy excitation ... Initial state occupied band k ... Cooper Pair -k k Conventional

Final Bloch states. Eo = “bottom of Muffin tin” – starting point for parabolic band dispersions = -9.34 eV for GaAs.

Direct or k-conserving transitions.

eφ = work function of sample, Ek=kinetic energy

Vo=Eo- eφ =“Inner potential”. Usually just a fitting parameter.

Normal emission: theta=0

Page 15: Angle Resolved Photoemission Spectroscopy€¦ · Angle resolved photoemission spectroscopy. Low energy excitation ... Initial state occupied band k ... Cooper Pair -k k Conventional

Normal emission: theta=0

Page 16: Angle Resolved Photoemission Spectroscopy€¦ · Angle resolved photoemission spectroscopy. Low energy excitation ... Initial state occupied band k ... Cooper Pair -k k Conventional
Page 17: Angle Resolved Photoemission Spectroscopy€¦ · Angle resolved photoemission spectroscopy. Low energy excitation ... Initial state occupied band k ... Cooper Pair -k k Conventional
Page 18: Angle Resolved Photoemission Spectroscopy€¦ · Angle resolved photoemission spectroscopy. Low energy excitation ... Initial state occupied band k ... Cooper Pair -k k Conventional

Measured linewidths Γm have a contribution from the lifetimes of the initial state (lifetime Γi) and final state (lifetime Γf).f

i

Final s

tate (

e.g. fr

ee

electr

on) u

noccu

pied

band

Initial st

ate

occupi

ed ban

d

kperp (and hν) value with maximum intensity (cross section)

kperp (and hν) value with half maximum intensity

Nearly 2D limit: vi perp small. Near isolation of Γi.

Page 19: Angle Resolved Photoemission Spectroscopy€¦ · Angle resolved photoemission spectroscopy. Low energy excitation ... Initial state occupied band k ... Cooper Pair -k k Conventional

•Can ignore kz dispersion. •Need not vary photon energy to map out Fermi surface and high symmetry directions.•Less final state broadening. Intrinsic initial-state linewidthscan be studied.

2D compounds

Page 20: Angle Resolved Photoemission Spectroscopy€¦ · Angle resolved photoemission spectroscopy. Low energy excitation ... Initial state occupied band k ... Cooper Pair -k k Conventional
Page 21: Angle Resolved Photoemission Spectroscopy€¦ · Angle resolved photoemission spectroscopy. Low energy excitation ... Initial state occupied band k ... Cooper Pair -k k Conventional

Photon E field (Polarizaton direction)

Zeros shifted by 45 degrees.

Electron emission direction

Sample spins

Page 22: Angle Resolved Photoemission Spectroscopy€¦ · Angle resolved photoemission spectroscopy. Low energy excitation ... Initial state occupied band k ... Cooper Pair -k k Conventional

Symmetry Analysis

The matrix element is integrated over all space.The integration axis of interest here is perpendicular to a chosen mirror plane.If net odd symmetry, then the matrix element integrates to exactly zero.

E field

Page 23: Angle Resolved Photoemission Spectroscopy€¦ · Angle resolved photoemission spectroscopy. Low energy excitation ... Initial state occupied band k ... Cooper Pair -k k Conventional

Matrix Element for Photoemission

Perturbation Theory gives Fermi’s Golden Rule fortransition probability

For dipole allowed transitions,

Page 24: Angle Resolved Photoemission Spectroscopy€¦ · Angle resolved photoemission spectroscopy. Low energy excitation ... Initial state occupied band k ... Cooper Pair -k k Conventional

binding energy

emission angle

MDC

EDC

Two dimensional electron detection

XYhn

A.D. Gromko, University of Colorado Thesis

Energy Distribution Curve (EDC)

Momentum Distribution Curve (MDC)

Page 25: Angle Resolved Photoemission Spectroscopy€¦ · Angle resolved photoemission spectroscopy. Low energy excitation ... Initial state occupied band k ... Cooper Pair -k k Conventional

Momentum Distribution Curve (MDC)Peak width ∆k = 1/l : l=electron mean free path.

Energy Distribution Curve (EDC)Peak width ∆E = hbar/τ1/τ=scattering rateτ=quasiparticle lifetime

2D detection on the high Tc superconductor Bi2Sr2CaCu2O8

∆E=∆k *dE/dk = ∆k * v

MDCs are usually more symmetric than EDCs (simple Lorentzian). à easier to fit

Page 26: Angle Resolved Photoemission Spectroscopy€¦ · Angle resolved photoemission spectroscopy. Low energy excitation ... Initial state occupied band k ... Cooper Pair -k k Conventional

2D detection on the high Tc superconductor Bi2Sr2CaCu2O8

Lorentzian MDC fits as as a function of temperature. Broader peaks at higher T àshorter photohole lifetimes.

Origin: Electron-electron scattering? Electron-phonon? Electron-impurity?The same mechanisms for scattering also affect other probes (optics, transport, etc.).Also the interactions responsible for the superconducting pairing?

Valla et al., Science (1999)

Page 27: Angle Resolved Photoemission Spectroscopy€¦ · Angle resolved photoemission spectroscopy. Low energy excitation ... Initial state occupied band k ... Cooper Pair -k k Conventional

Measured dispersion

“Bare” dispersion

“spectral function” = ARPES weight (k,ω)

“Kink effect”

Page 28: Angle Resolved Photoemission Spectroscopy€¦ · Angle resolved photoemission spectroscopy. Low energy excitation ... Initial state occupied band k ... Cooper Pair -k k Conventional

A(k,ω) peaks when [ω-εk-ReΣ]=0or whenω=εk+ReΣBare band: ReΣ=0Measured: ReΣ=finite.

Σ = electron “self energy”. Here the “kink” is due to electron-phonon scattering. (Phonon lives at kink scale or ~ 30 meV).

Measured dispersion

“Bare” dispersion

“spectral function” = ARPES weight (k,ω)

Difference

Page 29: Angle Resolved Photoemission Spectroscopy€¦ · Angle resolved photoemission spectroscopy. Low energy excitation ... Initial state occupied band k ... Cooper Pair -k k Conventional

Changes in the carrier mass due to electron-phonon couplingonly affects the near-EF states

From Ashcroft and Mermin, Solid State Physics,1976

Page 30: Angle Resolved Photoemission Spectroscopy€¦ · Angle resolved photoemission spectroscopy. Low energy excitation ... Initial state occupied band k ... Cooper Pair -k k Conventional

FWH

M o

f qu

asip

artic

lepe

ak

ImΣ = width of spectral peak Measurable in the same spectra.

ImΣ and ReΣ related through Kramers-Kronig relations.

Impurities, finite resolution, final state effects, etc.

Coupling to phonons

Electron-electron scattering

0

Page 31: Angle Resolved Photoemission Spectroscopy€¦ · Angle resolved photoemission spectroscopy. Low energy excitation ... Initial state occupied band k ... Cooper Pair -k k Conventional

Electronic Structure Factory at beamline 7, ALS

A data set.

Page 32: Angle Resolved Photoemission Spectroscopy€¦ · Angle resolved photoemission spectroscopy. Low energy excitation ... Initial state occupied band k ... Cooper Pair -k k Conventional

a) Sample charging – for insulating or weakly insulating samples.• Vary the photon flux and look for energy shifts.• Raise the sample temperature• Electron flood gun to replenish lost electrons

b) Space-charge effect – for high beam intensities. • Shifts and broadens peaks. • Only an issue for highest beam intensities, highest resolution.• Test by adjusting beam intensity.• May defocus beam on sample.

c) Sample ageing during measurements• Gas chemisorption or physisorption. Warming may regenerate.• Gas leaving the sample (e.g. oxides). Low temp helps.• Photon beam damage. Lower energy photons may help.• Measure quickly!• Measure many samples, doing different aspects in a different order.

d) Surface/cleave quality• Especially relevant for high angular resolution experiments.• Defects/impurities/step edges.• Different work functions for different faces.

Experimental issues:

Page 33: Angle Resolved Photoemission Spectroscopy€¦ · Angle resolved photoemission spectroscopy. Low energy excitation ... Initial state occupied band k ... Cooper Pair -k k Conventional

From ALS undulator beamline 10.0.1

Page 34: Angle Resolved Photoemission Spectroscopy€¦ · Angle resolved photoemission spectroscopy. Low energy excitation ... Initial state occupied band k ... Cooper Pair -k k Conventional

( 3 CuO L )T = 105 Kc

( 2 CuO L )T = 92 Kc

( 1 CuO L)T = 0 ~ 20 Kc

Bi2Sr2Ca2Cu3O10Bi2223

Bi

Sr

O

Cu

Ca

Bi-Sr-Ca-Cu-O family crystal structure

Main compound studied

Superconductivity occurs in the CuO2 planes

Bi2Sr2CaCu2O8Bi2212

Bi2Sr2CuO6Bi2201

Page 35: Angle Resolved Photoemission Spectroscopy€¦ · Angle resolved photoemission spectroscopy. Low energy excitation ... Initial state occupied band k ... Cooper Pair -k k Conventional

Recent ARPES results - kinks in HTSC’s(p,p) direction (nodal direction of d-wave gap)

Stanford GroupLanzara et al.

Nature 412,510 (2001)

Brookhaven GroupJohnson et al.

cond-mat/0102260 (2001).

Argonne GroupKaminski et al.

PRL 86, 1070 (2001)

Page 36: Angle Resolved Photoemission Spectroscopy€¦ · Angle resolved photoemission spectroscopy. Low energy excitation ... Initial state occupied band k ... Cooper Pair -k k Conventional

Kinks are strongly k-dependent.Kinks are temperature-dependent (strong below Tc).

Difficult for phonons? Magnetic interactions instead?

e)

kx

(π,π) (π,-π)

(0,0)

(π,0)

ky

Page 37: Angle Resolved Photoemission Spectroscopy€¦ · Angle resolved photoemission spectroscopy. Low energy excitation ... Initial state occupied band k ... Cooper Pair -k k Conventional

Reason for SC - formation of Cooper Pairs (two electrons form a Boson)

Pairs condense into macroscopic quantum SC state

Cooper Pair

-k k

Conventional SC - pairing mediated by electron-phonon interaction

+

++ +

+ +

+

+k

-k

Page 38: Angle Resolved Photoemission Spectroscopy€¦ · Angle resolved photoemission spectroscopy. Low energy excitation ... Initial state occupied band k ... Cooper Pair -k k Conventional

Conventional SCs: Tc~ 0- 30K, ∆ ~ 1-2meVHTSCs: Tc~ 100K, ∆ ~ 20-40 meV

The superconducting gap ?Energy to remove an electron from system - 1/2 of binding energy of the pair

Cooper Pair

-k k N (T>Tc)

0Energy

Den

sity

of s

tate

s

S (T<Tc)

Page 39: Angle Resolved Photoemission Spectroscopy€¦ · Angle resolved photoemission spectroscopy. Low energy excitation ... Initial state occupied band k ... Cooper Pair -k k Conventional

? small

-0.4 -0.3 -0.2 -0.1 0 0.1 0.2Energy Relative to the Fermi Level

Bi2212Tc = 78K

--- 20 K--- 85 K

A

B

Pho

toem

issi

on In

tens

ity

? large

Z.-X. Shen, D.S. Dessau et al., Phys. Rev. Lett. 70, 1553 (1993)

Gap magnitude maximal at (p,0), minimal or zero along (0,0)-(p,p) “nodal line.” --> dx2-y2 symmetry order parameter

Famous peak-dip-hump structure at (p,0). --> interaction with some mode?

(0,0) (π,0)

(π,π)

AB

Early gap measurements on HTSCs

0

s-wave

d-wave

(p,0)Nodalline

Page 40: Angle Resolved Photoemission Spectroscopy€¦ · Angle resolved photoemission spectroscopy. Low energy excitation ... Initial state occupied band k ... Cooper Pair -k k Conventional

Y

X

(0,0) (p ,0)

(p ,p )

Γ Mχ(spin) : known to be a singlet (S=0)

S = 0, l = 0-- s-wave superconductor

(conventional SC)

++-

-

S = 0, l = 2-- d-wave superconductor

(HTSCs - pretty sure)

Hole-like Fermi Surface

d-wave SC gap - maximal near (p,0)

Z-X Shen, D.S. Dessau et al, PRL 70, 1553 (1993).

Order parameter

? maximal

Node line? =0

++

-

-

Ψ(r1,σ1;r2,σ2)=ψ(orbital) χ(spin)•Antisymmetric under exchange

Superconducting order parameter symmetrySC gap ? = magnitude of order parameter. Varies as a function of k in a d-wave SC

Page 41: Angle Resolved Photoemission Spectroscopy€¦ · Angle resolved photoemission spectroscopy. Low energy excitation ... Initial state occupied band k ... Cooper Pair -k k Conventional

H. Ding, M.R. Norman, J.C. Campuzano, et al.

Page 42: Angle Resolved Photoemission Spectroscopy€¦ · Angle resolved photoemission spectroscopy. Low energy excitation ... Initial state occupied band k ... Cooper Pair -k k Conventional

H. Ding et al. Nature 382, 51 (1996).

antinode

UD samples “gapped” even above Tc.

Page 43: Angle Resolved Photoemission Spectroscopy€¦ · Angle resolved photoemission spectroscopy. Low energy excitation ... Initial state occupied band k ... Cooper Pair -k k Conventional

Node cold

Antinode cold

Antinode hot

Thought to exist between Tc and T* for UD samples.Similar magnitude as SC gap. Similar k-dependence as SC gap (d-wave).Obtained from leading edge analysis.

AlsoM. Norman et al, Nature 392, 157(1998).D.S. Marshall et al, PRL 76, 4841 (1996).A.G. Loeser et al. Science 273, 325 (1996).

UD83K UD10K

Page 44: Angle Resolved Photoemission Spectroscopy€¦ · Angle resolved photoemission spectroscopy. Low energy excitation ... Initial state occupied band k ... Cooper Pair -k k Conventional