annual pcb management plan dec 08,2009

Upload: jobpei2

Post on 07-Apr-2018

216 views

Category:

Documents


0 download

TRANSCRIPT

  • 8/6/2019 Annual Pcb Management Plan Dec 08,2009

    1/9

    PCB MANAGEMENT PLAN

    This PCB Management Plan is submitted in compliance with the provisions of Republic Act No. 6969,

    its Implementing Rules and Regulations, and DENR Administrative Order no. 01, Series of 2004 otherwise

    known as "Cemical Control Order for Polychlorinated Biphenyls."

    I. General Description

    Data Required Data

    1 Name of Owner and operator National Power Corporation

    2

    3 Industrial activities at the premises Operations of Diesel Power Plant

    4 Number of employees

    II. Uses of PCBs at the Premise

    Data Required Data

    1 Description of the uses of PCBs at the premises Power generation

    2

    3 Listing of PCB wastes generated at the premises

    None

    4 Mass balance of PCBs through the premises None

    5 Description of pollution control devices in use at the premises

    6

    7PCB Spill Oil Contigency Plan

    III. Pollution Prevention Program

    Data Required

    1 Pollution prevention/control devices

    2

    3

    IV. Training Program

    Data Required Data

    1 Scope or coverage of training or copy of the training Manual None

    2

    No trained personnel

    Prepared by: Approved by: Date:

    ItemNo.

    Location of the facility of the PCBs, PCB equipment, PCB-contaminated equipment, non-PCB equipment, PCB article,PCB packaging or PCB wastes (site specific)

    Taytay Diesel Power Plant, So Nalbot,Poblacion, Taytay, Palawan

    6 permanent NPC personnel includingthree security guard and one utility

    ItemNo.

    Listing of PCB equipment, PCB contaminated equipment, non-PCB equipment and PCB articles

    Power Transformer 3, attached laboratoryresults analysis made by CRLEnvironmental Corporation datedFebruary 05, 2009. (PCB's Not detected)Attached Certificate of PCB free from

    San Jiang electric Mfg. Co. Ltd.

    Each unit contain Smoke stack withsilencer

    Description of compliance with the environmental laws andregulations (attach separate sheet if necessary)

    Permit to Operate and Discharge Permitis available in the plant. Quarterlysubmission of SMR.

    Description of emergency procedures and contingency plan incase of accidents (attach separate sheet if necessary)

    ItemNo.

    Containment in concrete enclosure/drumcontainers with seal

    Inspection schedule and checklist (please attach sampleinspection checlist)

    Weekly, but limited only to visualinspection for leaks and safety conditionof the equipment

    Equipment and/or materials to used during spills and /oremergencies (attach separate sheet if necessary)

    Empty drums is available, rags, safetygoggles, respirator and first aid kit

    ItemNo.

    List of personnel trained, particularly those workers in contactwith PCBs, PCB equipment, PCB-contaminated equipment,

    non_PCB equipment, PCB wastes, PCB articles or PCBpackaging

  • 8/6/2019 Annual Pcb Management Plan Dec 08,2009

    2/9

    PAQUITO G. ALMENDRAL JEFFREY MO. D. OLLERAS

    Pollution Control Officer Manager, Palawan Area

  • 8/6/2019 Annual Pcb Management Plan Dec 08,2009

    3/9

    Chemical Control Order for Polychlorinated BiphenylsDENR ADMINISTRATIVE NO. 01, SERIES OR 2004

    PCB INVENTORY REPORT

    \ Period Covered: CY 2010

    I. COMPANY INFORMATION

    Name of Company NATIONAL POWER CORPORATION / TAYTAY DPP

    Business Address Agham Road, Corner Quezon Avenue, Diliman Quezon City

    Location of NPC-SPUG-PALAWAN AREA-TAYTAY DIESEL POWER PLANT

    Installation/Storage

    Facility So. Nalbot, Poblacion, Taytay, Palawan

    II. CONTACT INFORMATION

    Authorized Representative PAQUITO G. ALMENDRAL

    Position/Designation Principal Engineer C / Pollution Control Officer

    Telephone no./ Fax 048-434-4982

    Facsimile No.

    E-mail address

    III. PCB INVENTORY

    Date/s of Inventory 8-Dec-09

    Transformers Capacitors Others

    In Use 3 0 0

    On Standby 0 0 0

    For Rework 0 0 0

    On Storage for Disposal 0 0 0

    Total 3 0 0

    [email protected]

    EquipmentInformation

    mailto:[email protected]:[email protected]
  • 8/6/2019 Annual Pcb Management Plan Dec 08,2009

    4/9

    Inventory

    Name-Plated PCB Equipment, PCB-Contaminated Equipment, non-PCB Equuipment, PCB Articles and Labeled PCB Packaging

    Manufacturer Statu

    116113 1990 2020 1992 360 liters None In se

    116157 1990 2020 1992 445 liters None In se

    944545 2005 2040 2006 655 liters None In se

    * i.e. transformer, capacitor, circuit breaker, etc.

    ** i.e. Retro-filled, Repaired, Replaced, Decommissioned or Moved*** Status of PCB Equipment whether in Service, Idle, Unserviceable or in Storage

    **** Identification code corresponding to the equipment analyzed, i.e. sample number or lot number of the laboratory test report

    ***** Method or procedure used to establish PCB concentration

    Non-Plated PCB Equipment, PCB-Contaminated Equipment, non-PCB Equuipment, PCB Articles and Suspected PCB Packaging

    Equipment*/Device/Article/P

    ackaging Model/Serial

    Number

    Date ofManufactur

    e

    Electrical/Industrial Rating

    ProjectedRetirement

    Date

    Capacity/Dimensions of

    Unit

    Date Ac-quired

    Quantity/Volume of

    Oil

    PCB Concentration(ppm PCB)

    MaintenanceHistory**

    Amount ofPCB

    WastesGenerated

    PowerTransformer

    South Wales

    Transformer 225KVA/voltage

    ratio:14400Vprimary

    480Vsecondary

    1490 x1310 x1750 (mm)

    Attached Lab.

    Results of Analysisand Quality ControlData Report made

    by CRLEnvironmental

    Corporation lastFebruary 05, 2009

    No majorrepair has

    been doneto the unit as

    of to date

    PowerTransformer

    South WalesTransformer

    400KVA/voltage

    ratio:14400Vprimary

    480V

    secondary

    1490 x1345 x1900 (mm)

    Attached Lab.Results of Analysisand Quality ControlData Report made

    by CRLEnvironmental

    Corporation lastFebruary 05, 2009

    No majorrepair hasbeen done

    to the unit asof to date

    PowerTransformer

    MAN CXZTransformerSan Jiang

    ManufactureLimited

    700KVA/voltage

    ratio:14400Vprimary

    480Vsecondary

    2150 x 1850 x2000 (mm)

    Attached Certificateof free from PCB

    content powertransformer

    No majorrepair hasbeen done

    to the unit asof to date

  • 8/6/2019 Annual Pcb Management Plan Dec 08,2009

    5/9

    Status*

    NONE

    * i.e. transformer, capacitor, circuit breaker, etc.

    ** i.e. Retro-filled, Repaired, Replaced, Decommissioned or Moved

    *** Status of PCB Equipment whether in Service, Idle, Unserviceable or in Storage

    **** Identification code corresponding to the equipment analyzed, i.e. sample number or lot number of the laboratory test report

    ***** Method or procedure used to establish PCB concentration

    Equipment*/Device/Article

    /Packaging Model/Serial

    Number

    Manufacturer

    Date ofManufact

    ure

    Electrical/Industrial Rating

    ProjectedRetirement

    Date

    Capacity/Dimensions of

    Unit

    Date Ac-quired

    Quantity/Volumeof Oil

    PCB Concentration(ppm PCB)

    MaintenanceHistory**

    Amount ofPCB

    WastesGenerated

  • 8/6/2019 Annual Pcb Management Plan Dec 08,2009

    6/9

    IV. PCB WASTES

    Quantity of PCB Wastes Generated Per Unit Time

    Waste Type* Quantity Generated for the Year Location

    None No suspected PCB waste being genererated

    *fluids, sludge, slurry, scraps, contaminated equipment, soilm, and others

    Total Quantity of PCB Wastes for the Year: NONE

    I hereby certify that the above information are true and correct.

    Done this _____________ day of __________________, at __ Puerto Princesa City, Palawan

    PAQUITO G. ALMENDRAL - PCO

    Name/Signature of Authorized Representative

    J. Mo. D. OLLERAS Manager, Palawan Area

    Name/Signature of President/CEO/General Manager

    SUBSCRIBED AND SWORN before me, a Notary Public, this __________ day of

    ____________________, affiant exhibiting to me his Community Tax Receipt:

    Name CTR# Issued at Issued On

    ______________________ ________ ____________________ _______________

    PAQUITO G. ALMENDRAL 16672929 Puerto Princesa City Mar. 20, 2009

    Doc. No.

    Page No.

    Book No. Notary Public

    Series of

  • 8/6/2019 Annual Pcb Management Plan Dec 08,2009

    7/9

    PCB Spill Prevention and Clean-up Plan

    This PCB Spill Prevention and Clean-up Plan is submitted in compliance with the provisions of

    Republic act No. 6969, its implementing Rules and Regulations, and DENR Administrative Order No. 01,

    Series of 2004 otherwise known as "Chemical Control Order for Polychlorinated Biphenyls".

    I. Personnel Training

    1. Personnel must undergo on training regarding toxic and hazardous waste management

    specially on PCB and chemicals

    2. Personnel must acquired fundamental knowledge on industrial safety and chemical safety

    3. Regular training and seminars shall provide to all operations personnel to equip them with

    knowledge on how to handle emergencies.

    II. Markings and Labeling

    1. Containers with PCB contaminated are marked with hazardous waste, and must stored

    in a designated area complete with marking and labelling for proper identification.

    2. Containers with PCB concentrated are labeled with PCB sign warning/danger and stored in

    designated are with proper identification.

    III. Assignment/Resposibilities of Response Team

    1. All plant personnel including security guard and utilitiy are responsible in the storage,

    safekeeping, handling, labeling and inspection of hazardous waste from time to time.

    occurs and a contigency plan must place in a designated bullitin for safety.3. All plant personnel shall report to the Plant In-charge any inccident on spill or leak of

    containers and followed emergency procedure based on contigency plan.

    4. For any uncontrollable situation, Plant In-charge shall immediately inform the Area Manager,

    EMD and NPC Corporate Safety Officer

    5. The Plant In-charge/PCO shall report immediately to DENR-EMB and or PENRO/CENRO

    all accidents or spills and action taken to control release of chemicals to environment.

    6. Regular inspection of waste storage area shall be conducted by on duty personnel from

    time to time

    7. Proper wearing of PPE's shall be used at all time in handling hazardous wastes.

    2. All plant personnel shall responsible for the immediate action taken where aPCB spill

  • 8/6/2019 Annual Pcb Management Plan Dec 08,2009

    8/9

    IV. Emergency Plans

    NPC Corporate Contingency Plan must placed in a designated area

    for regular reminder's

    V. Decontamination Procedures

    1. To decontaminate a PCB container, flush the internal surfaces of the container three

    times with solvent containing no level of PCB or less tha 2.0 ppm PCB.

    Each rinse shall use a volume of the flushing solvent equal to approx. 10% of the

    PCB container capacitty

    2. To decontaminate movable equipment contaminated with PCB, tools and sampling

    equipment, any of the follwing is done:

    a. Swabbing surfaces that have contacted PCB with solvent

    b. A double wash/rinse as defined in procedure no. 1.

    3. The decontamination solvent used is either kerosene or diesel

    4. all contaminated materials are placed in containers or plastic bags and properly

    labeled

    5. Proper handling and disposal of waste materials shall be undertaken

    VI. Disposal of Contaminated Debris and Materials

    1. Proper coordination to implementing body for the safe and dispossal of PCB

    VII. Reporting and Record Keeping

    1. Quarterly submission of Self Monitoring Report

    2. Submission of Annual PCB Report every December.

    3. Semi-Annualy submission of Pro-Forma Proponent Compliance Monitoring Report(CMR) Module 5 of SMR

    VIII. Persons/Institutions to Contact in case of Emergency

    1. NPC - Environmental Management Department

    2. NPC Corporate Safety Officer

    3. CENRO - Taytay, Palawan

    4. LGU - Taytay, Palawan

    Prepared by: Approved by:

    PAQUITO G. ALMENDRAL JEFFREY Mo. D. OLLERAS

    PEC/Pollution Control Officer Manager, Palawan Area

  • 8/6/2019 Annual Pcb Management Plan Dec 08,2009

    9/9

    PCB Storage Facility Closure Plan

    This PCB Storage Facility Closure Plan is submitted in compliance with the provisions of

    Republic act No. 6969, its implementing Rules and Regulations, and DENR Administrative Order No. 01,

    Series of 2004 otherwise known as "Chemical Control Order for Polychlorinated Biphenyls".

    I. Certification of Financial Liability Approved by the Bureau

    1. Provide pollution liability insurance coverage

    2. Post annual surety bond equivalent of 150 % current cost of proper PCB disposal

    II. Steps and Procedures for Closure

    1. Transformer oil suspected PCB will be stored in a sealed container with marking

    and labelling and placed in designated area.

    2. Container suspected PCB will be stored in a concrete enclosure area, well ventilated,

    roof covered room, and concrete flooring with proper marking and labelling

    III. Post closure and monitoring

    1. Weekly inspection for suspected PCB equipment

    2. Visual inspection for leaking container to avoid spillage

    IV. Cost Estimates Approved by the Bureau

    1. Submit volume of suspected PCB to be disposed for cost estimate by the bureau

    Prepared by: Approved by:

    PAQUITO G. ALMENDRAL JEFFREY MARIO D. OLLERASPEC/Pollution Control Officer Manager, Palawan Area