antenna / antena - manuals.solidsignal.com / antena ref. 149881 a b f g x d e c h x2 k x2 l x4 j x2...

4
MATV Antenna / Antena Ref. 149881 A B G F X D E C H x2 L x4 K x2 J x2 I x2 M x2 N x2 S x3 Q x8 T x2 U x2 R x2 O x2 V x4 M6x25 M6x30 M6x40 (1) (2) (3) (4) (4) (1) (2) (3) 10 mm W

Upload: dinhthuan

Post on 18-Apr-2018

226 views

Category:

Documents


4 download

TRANSCRIPT

Page 1: Antenna / Antena - manuals.solidsignal.com / Antena Ref. 149881 A B F G X D E C H x2 K x2 L x4 J x2 I x2 M x2 N x2 Q x8 S x3 ... ANSI/NFPA70, or CSA C22.1 sections 10, 16, and 54,

MATV

Antenna / Antena

Ref. 149881

A

B

GF

X

D

E

C

H x2

L x4 K x2J x2

I x2

M x2 N x2

S x3Q x8

T x2U x2

R x2O x2

V x4

M6x25 M6x30

M6x40

(1)

(2)

(3)

(4)

(4)

(1)

(2)

(3)

10 m

m

W

Page 2: Antenna / Antena - manuals.solidsignal.com / Antena Ref. 149881 A B F G X D E C H x2 K x2 L x4 J x2 I x2 M x2 N x2 Q x8 S x3 ... ANSI/NFPA70, or CSA C22.1 sections 10, 16, and 54,

1 2

4 53

AA

A E

T

Q Q Q Q

T UU

F

G

S

S

S

J

J

B

B

D A

D

C

C

76V

Q

O

O

8

N

L

(1)(2)

(3) (4)

K

O

9M

R

10M

R

Page 3: Antenna / Antena - manuals.solidsignal.com / Antena Ref. 149881 A B F G X D E C H x2 K x2 L x4 J x2 I x2 M x2 N x2 Q x8 S x3 ... ANSI/NFPA70, or CSA C22.1 sections 10, 16, and 54,

16

20

15 17

9/32”(7mm)

1/8”(3mm)

12

14

11

13

CLICK!

CLICK!

CLICK!

CLICK!

H

I

I

H

18 19

CLICK!

X

Page 4: Antenna / Antena - manuals.solidsignal.com / Antena Ref. 149881 A B F G X D E C H x2 K x2 L x4 J x2 I x2 M x2 N x2 Q x8 S x3 ... ANSI/NFPA70, or CSA C22.1 sections 10, 16, and 54,

2016 © Copyright, Televés S.A.

Technical specifications / Características técnicas

Mode Modo BOSS OFF (Passive) BOSS ON (Active)

Operating band Banda de trabajo MHz 174 - 216(CH7 - CH13)

470 - 698(CH14 - CH51)

174 - 216(CH7 - CH13)

470 - 698(CH14 - CH51)

Gain Ganancia dBi 8.5 17 21 32

Output level Nivel de salida ---- Auto*

Noise figure Figura de ruido dB ---- 2 typ

Power supply Tensión de alimentación V 0 12 - 24

Consumption Consumo mA ---- 40 max

Beamwidth Ancho de haz º 27º

Wind load Carga al viento N 141 (@ 80 miles/h)194 (@ 93 miles/h)

*The gain is automatically adjusted according to the level of output / La ganancia varía automáticamente en función del nivel de salida.

Televes USA LLC 425 South Cherry Street, Suite 635 Denver, CO 80246 www.televes-usa.com [email protected] www.televes.com

Safety Instructions:LIGHTNING PROTECTION

If installed outdoors, be sure the antenna system is grounded so as to provide protection against voltage surges and built-up static charges. Section 810 of the National Electrical Code ANSI/NFPA70, or CSA C22.1 sections 10, 16, and 54, of the Canadian Electrical Code, provide information with respect to proper grounding of the mast and supporting structure, grounding of the antenna lead-in wire to an antenna discharge unit, size of grounding conductors, location of antenna-discharge unit, connection to grounding electrodes, and requirements for the grounding electrode (see figure and instructions).

Mount the lightning arrestor or 75 ohm coaxial grounding block as close as possible to where the 75 ohm coaxial cable downlead enters the house.

The ground wires for both the mast and the downlead should be copper or aluminum wire, number eight (8) or larger. The downlead wire from the antenna to the lightning arrestor and the mast ground wire should be secured to the house, spaced from four (4) to six (6) feet apart. In the case of a “ground up” antenna installation it may not be necessary to ground the mast if the mast extends four or more feet in the earth. Consult a TV serviceman for the proper depth in your location.

WARNINGS To prevent fire or shock hazard, do not expose the included power supply to rain or moisture. Installation of off-air antennas near power lines is dangerous.

For your safety, follow the installation instructions. Any alteration or modification to the product or usage not in accordance with product instructions voids the warranty.

Antenna Lead in Wire

Example of antenna grounding as per National Electrical Code, ANSI/NFPA 70

NEC - National Electrical Code

Ground clamp

Electric ServiceEquipment

Ground clamps

Power service Grounding Electrode System (NEC Art 250, Part H)

Antenna Discharge Unit(NEC Section 810-20)

(May substitute a 75 ohm Coax Grounding Block)

Grounding Conductors(NEC Section 810-21)

�����������

������������������������������������������

������������

����

�����������

��������

������������

�����������

������������������������������������������

������������

����

�����������

��������

������������