“ego ii” lever handle floor standing …“ego ii” lever handle floor standing single lever...

1
SPECIFICATIONS TROUBLESHOOTING “EGO II” LEVER HANDLE FLOOR STANDING SINGLE LEVER BATH & SHOWER SET S06725 CHECK POINT Water leaks around the handle 1 Tighten Handle is loose 2 Tighten PROBLEM SOLUTION 7 Hex. Key Cover Body Swivel Ring OPERATING CONDITIONS Water supply pressure : 0.05 ~ 0.75 MPa. Ensure that water supply is clean ( No Sand, Dirt, Etc.). 1. 2. Always wipe chrome plated area with dry soft cloth, and sometimes wipe it with cloth soaked in mild soap. MAINTENANCE R5 INSTALLATION 1 3 Sleeve Anchor * Cut the cover after the mortar dry 5 2 Screw 6 4 * Plastic Cover 6 X Ø6 Holes Floor Water Pass Make sure floor is flat Hot Water Supply Cold Water Supply Mortar Minimum Mortar Level Maximum Mortar Level Base COLD Cover a b Bolt Hex. Key Cap Body * Remove the Base Cover and keep the Bolt HOT Bolt (From step 6) 2. BOLT Flow Regulator Inside (Don’t remove) 1. CONNECTING NUT 8 Packing Flexible Hose Shower Rain Spray Button Massage Spray Button Packing 751 +20 0 55 +0 -20 Ø95 75 +0 -20 945 +20 0 637 +20 0 230 45° 51 30 697.5 +20 0 Floor 30 TX494SEL ATTENTION Use of abrasive cleaning material such as; detergents containing hydrochloric acids, thinner, polishing powder, and nylon brush is not recommended. Flow Regulator should not be remove because it could damage the system 1. 2.

Upload: others

Post on 27-May-2020

24 views

Category:

Documents


0 download

TRANSCRIPT

SPECIFICATIONS

TROUBLESHOOTING

“EGO II” LEVER HANDLE FLOOR STANDING SINGLE LEVER BATH & SHOWER SET

S06725

CHECKPOINT

Water leaks around the handle 1 TightenHandle is loose 2 Tighten

PROBLEM SOLUTION

7

Hex. Key Cover

Body

Swivel Ring

OPERATING CONDITIONSWater supply pressure : 0.05 ~ 0.75 MPa.Ensure that water supply is clean ( No Sand, Dirt, Etc.).

1.2.

Always wipe chrome plated area with dry soft cloth, and sometimes wipe it with cloth soaked in mild soap.

MAINTENANCE

R5

INSTALLATION 1

3

Sleeve Anchor

* Cut the cover after the mortar dry

5

2

Screw

6

4

* Plastic Cover

6 X Ø6 Holes

Floor

Water Pass

Make sure floor is flat

Hot Water Supply

Cold Water Supply

MortarMinimumMortar Level

MaximumMortar Level

Base

COLD

Cover

a

b

Bolt

Hex. Key

Cap Body

* Remove the Base Cover and keep the Bolt

HOT

Bolt(From step 6)

2. BOLT

Flow Regulator Inside (Don’t remove)

1. CONNECTING NUT

8

Packing

Flexible Hose

Shower

Rain Spray Button

Massage Spray Button

Packing

751+2

0 0

55+0 -2

0

Ø95

75+0 -2

094

5+20

0

637+2

0 0

230

45°

51 30

697.

5+20

0

Floor

30

TX494SEL

ATTENTIONUse of abrasive cleaning material such as; detergents containing hydrochloric acids, thinner, polishing powder, and nylon brush is not recommended.Flow Regulator should not be remove because it could damage the system

1.