appendix b proposal plans

15
Environmental Impact Statement Currawarra Solar Farm 17-099 V1 B-i APPENDIX B PROPOSAL PLANS

Upload: others

Post on 18-Jan-2022

2 views

Category:

Documents


0 download

TRANSCRIPT

Environmental Impact Statement Currawarra Solar Farm

17-099 V1 B-i

APPENDIX B PROPOSAL PLANS

09-11-2017INFRASTRUCTURE_06_20170927NA

NA

CONTAINS INFORMATION FROM STATE OF NEW SOUTH WALES(DEPARTMENT OF NATURAL RESOURCES AND MINES) 2017.

!(CONNECTION POINTTO TRANSGRID132kV POWERLINE

SE3

SE4

SE2

SE1

EMERGENCY ACCESS

Source: Esri, DigitalGlobe, GeoEye, Earthstar Geographics, CNES/Airbus DS, USDA, USGS, AeroGRID, IGN, and the GISUser Community

GDA 1994 MGA Zone 55

INFRASTRUCTURE

03747D1001-06

PLANNING PERMIT APPLICATION

CURRAWARRA SOLAR FARM

DRAWING NUMBER

1:15,000SCALE - @ A3COORDS

INFRAS DWG APPD DATELAYOUT DWG LAYOUT NO.

THIS DRAWING IS THE PROPERTY OF RES AUSTRALIA PTY LTD AND NO REPRODUCTION MAY BE MADE

IN WHOLE OR IN PART WITHOUT PERMISSION

1 2 3 4 5 6 7 8 9 10

A

G

E

F

C

B

D

1 2 3 4 5 6 7 8 9 10

A

G

E

F

C

B

D

SUITE 4, LEVEL 1760 PACIFIC HIGHWAYCHATSWOOD, NSW 2067TEL +61 (0)2 8440 7400EMAIL: [email protected]

LEGENDSINGLE AXIS 84 MODULE TRACKERPOWER CONVERSION UNIT WITHHARDSTANDING

!( SITE ENTRANCE

!? EMERGENCY ACCESS

PROPOSED NEW ACCESSTEMPORARY CONSTRUCTION COMPOUND ANDLAYDOWN

PROPOSED TRANSFORMER AND UTILITYFACILITY

PROPOSED BATTERY STORAGEPROPOSED SECURITY FENCEPROPOSED REROUTE OF 22kV POWERLINE

PROPOSED EASEMENT CORRIDOR! PROPOSED RELOCATED 22kV POLE

EXISTING 22kV POWERLINE TO BE REROUTEDEXISTING 22kV POWERLINE (ESSENTIALENERGY)

S EXISTING 22kV POLE (ESSENTIAL ENERGY)

E EXISTNG 132kV POLE (TRANSGRID)

EXISTING 132kV POWERLINE (TRANSGRID)TRANSGRID EASEMENT CORRIDOR

MURRY IRRIGATION EASEMENT CORRIDORSUBDIVIDED AREA CONTAINING TRANSGRIDSUBSTATION

CADASTRAL SITE BOUNDARY

NOTES:1. MAX NUMBER OF 5 CABLE CROSSINGS ACROSS MURRAYIRRIGATION CHANNEL (SUBJECT TO DETAILED DESIGN ANDAGREEMEMT WITH MI LTD). THESE ARE NOT SHOWN ON DRAWING.2. LAYOUT SHOWN IS INDICATIVE AND SUBJECT TO FINAL DESIGN BUTWILL BE GENERALLY IN ACCORDANCE WITH THIS DRAWING.

0 0.5 10.25km

UP

12000

RAMP TO AS1428.1

ACCESS STAIRS TO AS1428.1

DP TO TANK

CONTROL ROOM

PWD

VERANDA/ RECREATION AREATIMBER DECK

D1

1000

8

AMENITIES TO AS1428.1

FE

3.00°

TIMBER SCREENING TOGROUND

FC SHEETING APPLIED FINISH

COLORBOND BARGE ANDGUTTER

TANK

ALUMINIUM GLASS ENTRYAND DOOR

TIMBER SCREENING

FC SHEETING APPLIED FINISH

SCALE -

DRAWING NUMBER

LAYOUT DWGT-LAYOUT NO.

THIS DRAWING IS THE PROPERTY OF RES AUSTRALIA PTY LTD AND NO

REPRODUCTION MAY BE MADE IN WHOLE OR IN PART WITHOUT

PERMISSION

SUITE 4, LEVEL 1

760 PACIFIC HWY

CHATSWOOD, NSW 2067

TEL: +61 (0)2 8440 7400

EMAIL: [email protected]

PLANNING PERMIT APPLICATION

COORDS

G

1 2

F

E

D

3 4 5

C

B

A

1 2 3 4 5

6 7 8 9 10

6 7 8 9 10

INFRA DWGAPPD DATE

G

F

E

D

C

B

A

@A3N.T.S.

03707D4003-01

N/AN/A

ROOM

TYPICAL CONTROL

TECHNICAL FIGURE 8

SOLAR FARM

N/A 08-02-2017

N/A

PAGE 1 OF 2

ROOM SCHEDULE

NAME FLOOR FINISH AREA

GROUND FLOORCONTROL ROOM VINYL 60 m²PWD VINYL 7 m²VERANDA/RECREATION AREA

TIMBER DECK APPLIED FINISH 36 m²

Grand total 103 m²

1 GROUND FLOOR PLAN

2 WEST ELEVATION

3 NORTH ELEVATION

4 SOUTH ELEVATION 5 EAST ELEVATION

6 PERSPECTIVE

CONTROL ROOM LAYOUT

NOTES:1. INFRASTRUCTURE TO CONFORM TO AUSTRALIAN

STANDARDS, BCA/NCC AND LOCAL GOVERNMENTREGULATIONS;

2. LAYOUT AND DIMENSION ARE INDICATIVE ONLY -SUBJECT TO DETAILED DESIGN AND NOT FORCONSTRUCTION;

3. DIMENSION ARE IN MILLIMETRES;

4. LAYOUT AS SHOWN SUITED FOR ≤ 132kV.

AB

4500

2000

1 2

4500

2000

UP UP

1

A

B

5500

1600

2

52003800480015152

29500

HV SWITCH ROOM

PROTECTION ROOM SERVICESROOM

CONTROL ROOM

DC TRIPPING SUPPLY INCLUDING BATTERIES33kV SWITCHBOARD

PROTECTION AND METERING PANELS (VARIOUS)

AUXILIARY SUPPLY CHANGEOVER SWITCH / LV DIST. BOARD

SCADA / MONITORING PANELS

HUMAN MACHINE INTERFACE

SCALE -

DRAWING NUMBER

LAYOUT DWGT-LAYOUT NO.

THIS DRAWING IS THE PROPERTY OF RES AUSTRALIA PTY LTD AND NO

REPRODUCTION MAY BE MADE IN WHOLE OR IN PART WITHOUT

PERMISSION

SUITE 4, LEVEL 1

760 PACIFIC HWY

CHATSWOOD, NSW 2067

TEL: +61 (0)2 8440 7400

EMAIL: [email protected]

PLANNING PERMIT APPLICATION

COORDS

G

1 2

F

E

D

3 4 5

C

B

A

1 2 3 4 5

6 7 8 9 10

6 7 8 9 10

INFRA DWGAPPD DATE

G

F

E

D

C

B

A

@A3N.T.S.

03707D4003-01

N/AN/A

ROOM

TYPICAL CONTROL

TECHNICAL FIGURE 8

SOLAR FARM

N/A 08-02-2017

N/A

SWITCHROOM DETAIL

PAGE 2 OF 2

3 ELEVATION2 ELEVATION

1 FLOOR PLAN

NOTES:

1. INFRASTRUCTURE TO CONFORM TO AUSTRALIANSTANDARDS, BCA/NCC AND LOCAL GOVERNMENTREGULATIONS;

2. LAYOUT AND DIMENSION ARE INDICATIVE ONLY -SUBJECT TO DETAILED DESIGN AND NOT FORCONSTRUCTION;

3. DIMENSION ARE IN MILLIMETRES;

4. LAYOUT AS SHOWN SUITED FOR ≤ 132kV ;

5. COMMS TOWER DESIGN TO BE FINALISED THROUGHDISCUSSION WITH NETWORK PROVIDER.

SCALE -

DRAWING NUMBER

LAYOUT DWGT-LAYOUT NO.

THIS DRAWING IS THE PROPERTY OF RES AUSTRALIA PTY LTD AND NO

REPRODUCTION MAY BE MADE IN WHOLE OR IN PART WITHOUT

PERMISSION

SUITE 4, LEVEL 1

760 PACIFIC HWY

CHATSWOOD, NSW 2067

TEL: +61 (0)2 8440 7400

EMAIL: [email protected]

PLANNING PERMIT APPLICATION

COORDS

G

1 2

F

E

D

3 4 5

C

B

A

1 2 3 4 5

6 7 8 9 10

6 7 8 9 10

INFRA DWGAPPD DATE

G

F

E

D

C

B

A

@A3N.T.S

03707D2205-01

N/A

N/A

SINGLE AXIS TRACKER

TECHNICAL FIGURE 1

SOLAR FARM

N/A 06-01-2017

N/A

NOTES:

1. GROUND CLEARANCE WILL VARY AS REQUIRED BYTOPOGRAPHY;

2. ROW LENGTH WILL VARY DEPENDING ON ELECTRICALDESIGN;

3. INDICATIVE ROW LENGTH COULD BE UP TO 100m;

4. PV MODULES COULD BE INSTALLED IN PORTRAIT ORLANDSCAPE. ORIENTATION WILL DEPEND ON THEMODULE TYPE;

5. THE PILE DEPTH SHALL BE DETERMINED FOLLOWINGDETAILED GEOTECHNICAL SITE INVESTIGATION,TYPICALLY UP TO 2.4m. PILE HEIGHTS WILL CHANGE TOACCOMMODATE THE GRADE, SUBJECT TOGEOTECHNICAL DESIGN;

6. ACTUATOR TYPE AND LOCATION MAY VARY;

7. THE FINAL CONFIGURATION MAY BE SUBJECT TOCHANGE IN THE DETAILED DESIGN PHASE, BUT WILL BEGENERALLY IN ACCORDANCE WITH THIS DRAWING;

8. ACTUATOR TECHNOLOGY SUBJECT TO FINAL DESIGN.

NOTES

1. ALL DIMENSIONS ARE SUBJECT TO DETAILEDDESIGN;

2. A MINIMUM GROUND CLEARANCE OF AT LEAST115mm IS REQUIRED AND IT WILL VARY ASREQUIRED ACCORDING TO TOPOGRAPHY;

3. THE PILE DEPTH SHALL BE DETERMINEDFOLLOWING DETAILED GEOTECHNICAL SITEINVESTIGATION AND WILL TYPICALLY BE 1.5 - 1.7m.HOWEVER THE MAXIMUM DEPTH COULD BE UP TO2.4m;

4. PV MODULES ARE SHOWN IN ELEVATION VIEWINSTALLED IN LANDSCAPE, ALTHOUGH THEY MAY BEINSTALLED IN PORTRAIT TO SUIT SITE CONDITIONS.IF INSTALLED IN PORTRAIT WILL NOT EXCEEDMAXIMUM HEIGHT.

SCALE -

DRAWING NUMBER

LAYOUT DWGT-LAYOUT NO.

THIS DRAWING IS THE PROPERTY OF RES AUSTRALIA PTY LTD AND NO

REPRODUCTION MAY BE MADE IN WHOLE OR IN PART WITHOUT

PERMISSION

SUITE 4, LEVEL 1

760 PACIFIC HWY

CHATSWOOD, NSW 2067

TEL: +61 (0)2 8440 7400

EMAIL: [email protected]

PLANNING PERMIT APPLICATION

COORDS

G

1 2

F

E

D

3 4 5

C

B

A

1 2 3 4 5

6 7 8 9 10

6 7 8 9 10

INFRA DWGAPPD DATE

G

F

E

D

C

B

A

A3N.T.S

03707D2202-01

N/AN/A

DETAIL - PILED FOUNDATION

TYPICAL PV MODULE & RACK

TECHNICAL FIGURE 1

SOLAR FARM

N/A 06-01-2017

N/A

NOTES:

1. ALL DIMENSIONS ARE MAXIMUM ANTICIPATED AND SUBJECT TODETAILED DESIGN;

2. ROOM AND DOOR POSITIONS ARE INDICATIVE AND SUBJECT TODETAILED DESIGN;

3. APPROXIMATE FINISHED FLOOR LEVEL 300mm ABOVE EXISTINGGROUND.

SCALE -

DRAWING NUMBER

LAYOUT DWGT-LAYOUT NO.

THIS DRAWING IS THE PROPERTY OF RES AUSTRALIA PTY LTD AND NO

REPRODUCTION MAY BE MADE IN WHOLE OR IN PART WITHOUT

PERMISSION

SUITE 4, LEVEL 1

760 PACIFIC HWY

CHATSWOOD, NSW 2067

TEL: +61 (0)2 8440 7400

EMAIL: [email protected]

PLANNING PERMIT APPLICATION

COORDS

G

1 2

F

E

D

3 4 5

C

B

A

1 2 3 4 5

6 7 8 9 10

6 7 8 9 10

INFRA DWGAPPD DATE

G

F

E

D

C

B

A

A3N.T.S

03707D4001-02

N/AN/A

CONVERSION UNIT - PCU

TYPICAL POWER

TECHNICAL FIGURE 4

SOLAR FARM

N/A 08-12-2016

N/A

SCALE -

DRAWING NUMBER

LAYOUT DWGT-LAYOUT NO.

THIS DRAWING IS THE PROPERTY OF RES AUSTRALIA PTY LTD AND NO

REPRODUCTION MAY BE MADE IN WHOLE OR IN PART WITHOUT

PERMISSION

SUITE 4, LEVEL 1

760 PACIFIC HWY

CHATSWOOD, NSW 2067

TEL: +61 (0)2 8440 7400

EMAIL: [email protected]

PLANNING PERMIT APPLICATION

COORDS

G

1 2

F

E

D

3 4 5

C

B

A

1 2 3 4 5

6 7 8 9 10

6 7 8 9 10

INFRA DWGAPPD DATE

G

F

E

D

C

B

A

A3N.T.S

03707D3504-01

N/A

N/A

STORAGE SOLUTION

ENERGY

CONTAINERS

FIGURE 10

SOLAR FARM

N/A 12-09-17

N/A

NOTES

1. STORAGE SITE BOUNDARY APPROXIMATE 1 HAs;

2. SUBJECT TO FINAL DESIGN WHICH WILL BE GENERALLY IN ACCORDANCEWITH THIS DRAWING;

3. SITE TO BE ENCLOSED AROUND PERIMETER BY 2m SECURITY FENCING;

4. CAR PARK FOR UP TO SIX VEHICLES TO BE PROVIDED;

5. SUBJECT TO FINAL APPROVAL DESIGN;

6. ALL DIMENSIONS ARE APPROXIMATE;

10. ALL CABLING TO BE UNDERGROUND OR ON CABLING TRAY;

11.FOUNDATIONS ARE INDICATIVE AND SUBJECT TO ACTUAL ELECTRICALEQUIPMENT DETAILS;

12.DOOR AND STEPS POSITIONS ARE INDICATIVE AND SUBJECT TO DETAILEDDESIGN;

13. APPROXIMATE FINISHED FLOOR LEVEL 0.5m ABOVE EXISTING GROUND LEVEL;

14.STEPS TO BE EITHER CONSTRUCTED ON SITE FROM MASS CONCRETE ORMASONRY BLOCKS OR PREFABRICATED OFF SITE AND INSTALLED ON SITEFOLLOWING POSITIONING OF THE STORAGE UNIT;

15. THE LOCATION AND SIZE OF ENERGY STORAGE UNIT WITHIN THE CONTAINERTO BE DETERMINED AT DETAILED DESIGN STAGE;

16.EXTERNAL COLOUR OF ENERGY STORAGE UNIT TO BE AGREED;

17.FIRE SUPPRESSION SYSTEM INTERNAL TO CONTAINER.

POWER CONVERSION SYSTEM - PCS

TRANSFORMER

AUXILIARY TRANSFORMER

CONTAINER

STORAGE AREA

DOOR

PASSIVE INFRARED LIGHTING (PLAN)

PASSIVE INFRARED LIGHTING (ELEVATION)

LEGEND

SCALE -

DRAWING NUMBER

LAYOUT DWGT-LAYOUT NO.

THIS DRAWING IS THE PROPERTY OF RES AUSTRALIA PTY LTD AND NO

REPRODUCTION MAY BE MADE IN WHOLE OR IN PART WITHOUT

PERMISSION

SUITE 4, LEVEL 1

760 PACIFIC HWY

CHATSWOOD, NSW 2067

TEL: +61 (0)2 8440 7400

EMAIL: [email protected]

PLANNING PERMIT APPLICATION

COORDS

G

1 2

F

E

D

3 4 5

C

B

A

1 2 3 4 5

6 7 8 9 10

6 7 8 9 10

INFRA DWGAPPD DATE

G

F

E

D

C

B

A

@A3N.T.S

03707D3503-01

N/A

N/A

TYPICAL STORAGE SHED

TECHNICAL FIGURE 9

SOLAR FARM

N/A

19-12-2016

N/A

NS

E W

PERSPECTIVE3D STORAGE SHED

1 STORAGE SHED FLOOR PLAN

STORAGE SHED EASTERN ELEVATION

STORAGE SHED NORTH ELEVATIONSTORAGE SHED SOUTHERN ELEVATION

STORAGE SHED WESTERN ELEVATION

NOTES:

1.

2.

3.

4.

5.

ROLLER DOORS TO BE DESIGNED TO MEET PRESSURE CAPACITYREQUIREMENTS OF THE REGION

DISABILITY ACCESS TO COMPLY WITH AS1428.1 INCLUDING AMAXIMUM THRESHOLD OF 5mm AND CARPARK GRADES TO BE AMAXIMUM OF 1 IN 40 (2.5%) FROM DISABILITY CARPARK TOBUILDING.

CONCRETE TILT PANELS TO COMPLY WITH BCA CL 1.11.

REFER GENERAL NOTES ON 001 FOR FURTHER NOTES ANDABBREVIATIONS

REFER TO THE SCHEDULE OF FIXTURES AND FINISHES FOR

SPECIFICATIONS

EMERGENCY LIGHTING SCHEDULE

EXIT

TO COMPLY WITH AS2293.1-2005 AND B.C.A. PART E4.

SYMBOL C0 C90 HEIGHT DESCRIPTION

D50 C50 5000 STANILITE ECBT136M, MAINTAINED

D25 D25 2700 STANILITE ESFLED

D2.5 E2.5 2400 STANILITE EELED

36W SINGLE, BARE BATTEN

10W MAINTAINED, SINGLE SIDE

FHR 36m x 19mm ID FIRE HOSE REEL INSTALLEDIN ACCORDANCE WITH AS2441

FE 4.5kg 4A:60B(E) DRY CHEMICAL FIRE EXTINGUISHERINSTALLED IN ACCORDANCE WITH AS2444-1990

B BOLLARDREFER SLAB DETAILS FOR BOLLARD DETAILS

D1 DOOR TAG, REFER DOOR SCHEDULE FOR DETAILS

W1 WINDOW TAG, REFER WINDOW SCHEDULE FORDETAILS

CW1 CURTAIN WALL TAG, REFER NON-STANDARD WINDOWSCHEDULE FOR DESCRIPTION, REFER ELEVATIONSAND PLAN FOR MULLION SETOUT

P1 WALL TAG, REFER WALL SCHEDULE FOR WALL TYPE,INSULATION AND FINISH

DP DOWNPIPEREFER STORMWATER PLAN FOR SIZE

CIRCULATION SPACE TO AS1428.1-2009

MIN. 920 DOOR TO AS1428.1-2009(MIN. 850 CLEAR)

CIRCULATION SPACE TO AS1428.1-2009

WALL

LEGEND - FLOOR PLAN

PROPOSED WALLREFER WALL SCHEDULE FOR TYPE

3

innovation, ingenuity, inspiration engineering consultantsi consulting pty ltd

ABN 89 106 675 156 ACN 106 675 156www.icubed.com.au [email protected]

LV2, 39 Sherwood Rd PO Box 878Toowong, Qld 4066 Toowong, Qld 4066

p 07 3870 8888

NOTES

LAYOUTS AND DIMENSIONS ARE INDICATIVE ONLY TO SHOW GENERALARRANGEMENT CONCEPTS AND ALL DETAILS ARE SUBJECT TO FINALDESIGN;

THE FINAL DESIGN WILL BE GENERALLY IN ACCORDANCE WITH WHAT ISSHOWN;

BASED ON I³ DRAWINGS:- 'SITE PLAN DETAILED' PROJECT 16-104 DRAWINGS No. 16-104-A01-C,16-104 - A02 -A AND 16-104-A03-B.

STORAGE AREA

ACC

ESS

TRAC

K

TURNING AREA

50m

CONTAINERS FORSUBCONTRACTOR USE

TOILETS

SITE VEHICLE PARKING

SUB CONTRACTOR OFFICE,DRYING ROOM & CANTEEN OFFICE & MEETING

ROOM

SKIPS WITH WIND SHIELDAND LID

CONTAINERS

VEHICLE GATE(SEE NOTE 5)

VEHICLE GATE(SEE NOTE 5)

CHAIN LINK FENCE(SEE DETAIL)

SITE VEHICLEPARKING

50m

FOUL WATERTREATMENTMEASURES

( SEE NOTE 4)

OIL SEPARATIONMEASURES

(NOTE 4)

BUNDED REFUELINGAREA WITH ROOF

GENERATOR FOR CONSTRUCTIONCOMPOUND POWER SUPPLY

SITE VEHICLEPARKING

LAYBY FOR TEMPORARYPARKING

PEDESTRIAN ACCESS GATE

FENCE 1.2m HIGH BETWEENPEDESTRIAN AND VEHICULARAREAS

PEDESTRIAN ACCESS GATE

CHAIN LINK FENCE

MAX

HEI

GH

T 2m

.

TYPICAL FENCE PANELNOT TO SCALE

PLANSCALE - 1:300

NOTES

1. SIZE, NUMBER AND LOCATION OF COMPOUND EQUIPMENTAND FACILITIES ARE INDICATIVE ONLY;

2. STRUCTURE TO BE TEMPORARY AND TO BE REMOVEDAFTER CONSTRUCTION;

3. COMPOUND HARDSTANDING CONSISTING OFCOMPACTED STONE TO PROVIDE A CLEAN, FIRM, LEVELAND FREE DRAINING SURFACE SUITABLE FOR CABINSAND HEAVY TRAFFIC;

4. APPROPRIATE MEASURES FOR SEPARATION OF OILS ANDTREATMENT OF FOUL WATER TO BE AGREED WITH THERELEVANT AUTHORITIES;

5. VEHICULAR GATES TO BE 6m WIDE CONSISTING OF 2 x 3mLEAVES;

6. COMPOUND EQUIPMENT AND FACILITIES ARE INDICATIVE,BUT SHALL BE CONSTRUCTED ACCORDING TO THEPRINCIPLES NOTED ON THIS PLAN AND AS PER THEAPPROVED MANAGEMENT PLANS;

7. FOR INDICATIVE LOCATION OF SATELLITE CONSTRUCTIONCOMPOUNDS REFER TO THE INFRASTRUCTURE DRAWING;

8. MAXIMUM FENCE HEIGHT 2m.

SCALE -

DRAWING NUMBER

LAYOUT DWGT-LAYOUT NO.

THIS DRAWING IS THE PROPERTY OF RES AUSTRALIA PTY LTD AND NO

REPRODUCTION MAY BE MADE IN WHOLE OR IN PART WITHOUT

PERMISSION

SUITE 4, LEVEL 1

760 PACIFIC HWY

CHATSWOOD, NSW 2067

TEL: +61 (0)2 8440 7400

EMAIL: [email protected]

PLANNING PERMIT APPLICATION

COORDS

G

1 2

F

E

D

3 4 5

C

B

A

1 2 3 4 5

6 7 8 9 10

6 7 8 9 10

INFRA DWGAPPD DATE

G

F

E

D

C

B

A

A3N.T.S

03707D3502-03

N/AN/A

COMPOUND

CONSTRUCTION

TYPICAL TEMPORARY

TECHNICAL FIGURE 3

SOLAR FARM

N/A 24-01-2017

N/A

LEGENDOPTIONAL SECURITY FENCE

NER

A A

33kV SWITCH ROOM

AREA FOR REACTIVEPLANT(IF REQUIRED)

AREA FOR REACTIVEPLANT(IF REQUIRED)

AUXILIARYTRANSFORMER

BACKUPGENERATOR

1 2 3 4 5 6 71

8

CONTROLROOM

STORAGESHED

GRAVEL TO SWITCHYARD

POSSIBLE TNSP SWITCHING YARD

SECURITY FENCE

SECURITY FENCE

CONC

RETE

ACC

ESS

75000 60000

5500

0

COMMSTOWER

WATER TANK

NER

BUS BAR IF TNSP SWITCHING YARD

9

STORAGE SHED (REFER DETAIL)CONTROL ROOM (REFER DETAIL)

33kV SWITCH ROOM

EQUIPMENT BEYOND (REFER SECTION)

SECURITY FENCE

EQUIPMENT No.

EQUIPMENT SCHEDULE:DESCRIPTION

1 POLE C/W LIGHTNING FINIAL AND AREA LIGHTING2 MAIN TRANSFORMER C/W SURGE ARRESTORS3 INSULATED POST4 CIRCUIT BREAKER C/W CURRENT TRANSFORMERS5 DISCONNECTOR6 VOLTAGE TRANSFORMER7 SURGE ARRESTOR8 INCOMING LINE GANTRY9 COMMS TOWER

SCALE -

DRAWING NUMBER

LAYOUT DWGT-LAYOUT NO.

THIS DRAWING IS THE PROPERTY OF RES AUSTRALIA PTY LTD AND NO

REPRODUCTION MAY BE MADE IN WHOLE OR IN PART WITHOUT

PERMISSION

SUITE 4, LEVEL 1

760 PACIFIC HWY

CHATSWOOD, NSW 2067

TEL: +61 (0)2 8440 7400

EMAIL: [email protected]

PLANNING PERMIT APPLICATION

COORDS

G

1 2

F

E

D

3 4 5

C

B

A

1 2 3 4 5

6 7 8 9 10

6 7 8 9 10

INFRA DWGAPPD DATE

G

F

E

D

C

B

A

A3N.T.S.

03707D4004-01

N/A

N/A

SINGLE TRANSFORMER

FACILITY LAYOUT

INDICATIVE UTILITY

TECHNICAL FIGURE 7

SOLAR FARM

N/A 08-02-2017

N/A

GENERAL ARRANGEMENT

PAGE 1 OF 2

1 SITE PLAN

2 ELEVATION

1. INFRASTRUCTURE TO CONFORM TO AUSTRALIANSTANDARDS, BCA/NCC AND LOCAL GOVERNMENTREGULATIONS;

2. LAYOUT AND DIMENSION ARE INDICATIVE ONLY -SUBJECT TO DETAILED DESIGN AND NOT FORCONSTRUCTION;

3. DIMENSION ARE IN MILLIMETRES;

4. LAYOUT AS SHOWN SUITED FOR ≤ 132kV ;

5. COMMS TOWER DESIGN TO BE FINALISED THROUGHDISCUSSION WITH NETWORK PROVIDER.

NOTES:

BUILDING AREA (GROSS)

Ground Floor33kV SWITCH ROOM 162 m²CONTROL ROOM 72 m²STORAGE SHED 300 m²VERANDA/ RECREATION AREA 37 m²

Grand total 572 m²

2120

0

1 2 3 4 5 6 7 1 8

CONNECTION TO TNSPNETWORK OR ADJACENTTNSP BUSBAR

CO

MM

S T

OW

ER

H

EIG

HT

M

AY

V

AR

Y

9

EQUIPMENT No.

EQUIPMENT SCHEDULE:DESCRIPTION

1 POLE C/W LIGHTNING FINIAL AND AREA LIGHTING2 MAIN TRANSFORMER C/W SURGE ARRESTORS3 INSULATED POST4 CIRCUIT BREAKER C/W CURRENT TRANSFORMERS5 DISCONNECTOR6 VOLTAGE TRANSFORMER7 SURGE ARRESTOR8 INCOMING LINE GANTRY9 COMMS TOWER

SCALE -

DRAWING NUMBER

LAYOUT DWGT-LAYOUT NO.

THIS DRAWING IS THE PROPERTY OF RES AUSTRALIA PTY LTD AND NO

REPRODUCTION MAY BE MADE IN WHOLE OR IN PART WITHOUT

PERMISSION

SUITE 4, LEVEL 1

760 PACIFIC HWY

CHATSWOOD, NSW 2067

TEL: +61 (0)2 8440 7400

EMAIL: [email protected]

PLANNING PERMIT APPLICATION

COORDS

G

1 2

F

E

D

3 4 5

C

B

A

1 2 3 4 5

6 7 8 9 10

6 7 8 9 10

INFRA DWGAPPD DATE

G

F

E

D

C

B

A

A3N.T.S

03707D4004-01

N/A

N/A

SINGLE TRANSFORMER

FACILITY LAYOUT

INDICATIVE UTILITY

TECHNICAL FIGURE 7

SOLAR FARM

N/A 08-02-2017

N/A

GENERAL ARRANGEMENT

SECTION

PAGE 2 OF 2

SECTION

NOTES:1. INFRASTRUCTURE TO CONFORM TO AUSTRALIAN

STANDARDS, BCA/NCC AND LOCAL GOVERNMENTREGULATIONS;

2. LAYOUT AND DIMENSION ARE INDICATIVE ONLY -SUBJECT TO DETAILED DESIGN AND NOT FORCONSTRUCTION;

3. DIMENSION ARE IN MILLIMETRES;

4. LAYOUT AS SHOWN SUITED FOR ≤ 132kV ;

5. COMMS TOWER DESIGN TO BE FINALISED THROUGHDISCUSSION WITH NETWORK PROVIDER.

A

SCALE -

DRAWING NUMBER

LAYOUT DWGT-LAYOUT NO.

THIS DRAWING IS THE PROPERTY OF RES AUSTRALIA PTY LTD AND NO

REPRODUCTION MAY BE MADE IN WHOLE OR IN PART WITHOUT

PERMISSION

SUITE 4, LEVEL 1

760 PACIFIC HWY

CHATSWOOD, NSW 2067

TEL: +61 (0)2 8440 7400

EMAIL: [email protected]

PLANNING PERMIT APPLICATION

COORDS

G

1 2

F

E

D

3 4 5

C

B

A

1 2 3 4 5

6 7 8 9 10

6 7 8 9 10

INFRA DWGAPPD DATE

G

F

E

D

C

B

A

@A3N.T.S

03707D3501-03

N/AN/A

TRACK DETAIL

TYPICAL ACCESS

TECHNICAL FIGURE 2

SOLAR FARM

N/A 02-08-2017

N/A

GENERAL SITE ROAD DETAILS SHOWN, WHERE POSSIBLE AREAS OF FILL TOBE AVOIDED, ADDITIONAL WIDENING OF TRACK REQUIRED ON CORNERSAND PASSING BAYS TO ACCOMMODATE TRAFFIC;

ADDITIONAL TEMPORARY TRACK WIDENING MAY BE REQUIRED FOR CRANEMOVEMENTS. WIDENED ZONES TO BE REMOVED AT THE DISCRETION OF THEREGULATING AUTHORITY;

TRACK WIDTH WIDENED LOCALLY TO PROVIDE PASSING BAYS & TURNINGHEADS;

ALL MEASUREMENTS ARE INDICATIVE BUT FINAL DESIGN WILL BECONSISTENT WITH WHAT IS SHOWN.

LEGEND

EXISTING GROUND PROFILE

FINISHED GROUND PROFILE

ENGINEERED FILL

CRUSHED STONE PAVEMENT

EXISTING GROUND

RESPREAD TOPSOIL

NOTES

NOTES:

1. ALL DIMENSIONS ARE MAXIMUM ANTICIPATED AND SUBJECT TODETAILED DESIGN;

2. SECURITY LIGHTING MAY BE INFRARED;

3. LIGHTING AND CCTV SUPPORTS TO BE LOCATED ADJACENT TOSECURITY FENCING;

4. CAMERAS MAY BE INSTALLED WITH PAN FUNCTION;

5. TO BE INSTALLED IF REQUIRED BY INSURERS.

SCALE -

DRAWING NUMBER

LAYOUT DWGT-LAYOUT NO.

THIS DRAWING IS THE PROPERTY OF RES AUSTRALIA PTY LTD AND NO

REPRODUCTION MAY BE MADE IN WHOLE OR IN PART WITHOUT

PERMISSION

SUITE 4, LEVEL 1

760 PACIFIC HWY

CHATSWOOD, NSW 2067

TEL: +61 (0)2 8440 7400

EMAIL: [email protected]

PLANNING PERMIT APPLICATION

COORDS

G

1 2

F

E

D

3 4 5

C

B

A

1 2 3 4 5

6 7 8 9 10

6 7 8 9 10

INFRA DWGAPPD DATE

G

F

E

D

C

B

A

A3N.T.S.

03707D2201-02

N/AN/A

& CCTV SUPPORT DETAILS

TYPICAL SECURITY LIGHTING

TECHNICAL FIGURE 6

SOLAR FARM

N/A 08-12-2016

N/A

NOTES:

1. ALL DIMENSIONS ARE MAXIMUMANTICIPATED AND SUBJECT TODETAILED DESIGN.

SCALE -

DRAWING NUMBER

LAYOUT DWGT-LAYOUT NO.

THIS DRAWING IS THE PROPERTY OF RES AUSTRALIA PTY LTD AND NO

REPRODUCTION MAY BE MADE IN WHOLE OR IN PART WITHOUT

PERMISSION

SUITE 4, LEVEL 1

760 PACIFIC HWY

CHATSWOOD, NSW 2067

TEL: +61 (0)2 8440 7400

EMAIL: [email protected]

PLANNING PERMIT APPLICATION

COORDS

G

1 2

F

E

D

3 4 5

C

B

A

1 2 3 4 5

6 7 8 9 10

6 7 8 9 10

INFRA DWGAPPD DATE

G

F

E

D

C

B

A

A3N.T.S

03707D2204-02

N/AN/A

FENCE DETAIL

TYPICAL STOCK

TECHNICAL FIGURE 5

SOLAR FARM

N/A

08-12-2016

N/A

NOTES:

1. TO BE INSTALLED IF REQUIRED BY INSURERS.