Appendix to ISO/lEG 17025 accreditation certificatenumber: L 240

of Thales Nederland B.V.Environmental Competence CentreHengelo

Valid from: 01-07-2008 till 26-05-2011 Replaces appendix dated: 26-05-2007

Nr. Material or Product Type of activity Internal referencenumber

EMC Test

n ................................................................

Ir. J.C. van der Poel

i ~.~.i.~.~..~~~.~~.~i~.~ i

nex has been approved by:

Page 1 of 3

1 Electronic and/or electric Conducted Emission measurement on Power 9501 120 276xx

apparatus Leads, 30 Hz-10 kHz conformMIL-STD4610,CE101

2 Conducted Emission measurement on Power 9501 120 277xxLeads, 10 kHz-10 MHz conformMIL-STD461D,CE102

3 Conducted Immunity measurement on Power 9501 120 250xx

Leads, 30 Hz- 50 kHz conformMIL-STD4610, CS101

4 Conducted Susceptibility measurement on all 9501 120 257xx

Leads, 10 kHz- 30 MHz conformMIL-STD461D,CS114

5 Conducted Susceptibility measurement on all 9501 120 258xx

Leads, damped sine - 10 kHz- 100 MHz conformMIL-STD461D,CS116

6 Radiated Emission measurement 9501 120 376xxH-field 30 Hz-100 kHz conformMIL-STD461D,RE101

7 Radiated Emission measurement, 9501 120 442xxE-field 10 kHz-18 GHz conformMIL-STD4610, RE102

8 Radiated Susceptibility measurement, 9501 120 272xx

H-field, 30 Hz-100 kHz conformMIL-STD461D,RS101

9 Radiated Susceptibility measurement, 9501 120 274xxE-field, 14 kHz-18 GHz conformMIL-STD461D,RS103

10 Conducted Emission measurement on Power 9501 027 905xx

Leads, 30 Hz- 10kHz conformMIL-STD461E,CE101

11 Conducted Emission measurement on Power 9501 027 906xxLeads, 10 kHz- 10 MHz conformMIL-STD461E,CE102

12 Conducted Susceptibility measurement on Power 9501 027 91Oxx

Leads, 30 Hz- 150 kHz conformMIL-STD461E,CS101

Appendix to ISO/lEG 17025 accreditation certificatenumber: L 240

of Thales Nederland B.V.Environmental Competence CentreHengelo

Valid from: 01-07-2008 till 26-05-2011 Replaces appendix dated: 26-05-2007

Page 2 of 3

Nr. Material or Product Type of activity Internal referencenumber

13 Electronic and/or electric Conducted Susceptibility measurement on all 9501 027 911 xx

apparatus Leads, BCI - 10 kHz- 200 MHz conformMIL-STD461E,CS114

14 Conducted Susceptibility measurement on all 9501 027912xx

Leads, impulse excitation conformMIL-STD461E,CS115

15 Conducted Susceptibility measurement on all 9501 027 913xx

Leads, damped sine - 10 kHz- 100 MHz conformMIL-STD461E,CS116

16 Radiated emission measurement, H-field 9501 027 907xx30 Hz- 100 kHz conformMIL-STD461E,RE101

17 Radiated Emission measurement, E-field 9501 027 908xx10 kHz- 18 GHz conformMIL-STD461E,RE102

18 Radiated Immunity measurement, H-field 9501 027914xx30 Hz- 100 kHz conformMIL-STD461E,RS101

19 Radiated Immunity measurement, E-field 9501 027 915xx2 MHz - 18 GHz conformMIL-STD461E,RS103

20 ESD Immunity test 9501 120 445xxconformEN6100-4-2

21 Radiated Immunity measurement, 9501 120 446xxE-field 80 MHz-2 GHz conformEN61000-4-3

22 Conducted Immunity measurement on Power and 9501 120 447xxInterconnection Leads, Transients/Burst conformEN6100-4-4

23 Conducted Immunity measurement on Power and 9501 120 448xx

Interconnection Leads, Surges conformEN61000-4-5

24 Conducted Immunity measurement on Power and 9501 120 449xx

Interconnection Leads, CW, 150 kHz-80 MHz conformEN6100-4-6

25 Radiated Immunity measurement at Power 9501 120 840xx

frequency conform EN 61000-4-8

26 Conducted Emission measurement at Mains 9501 120 455xxPower Connection, Harmonic Currents conformEN61000-3-2

27 Conducted Emission measurement at Mains 9501 120 456xx

Power Connection, Voltage Fluctuation and Flicker conformEN61000-3-3

28 Conducted Immunity measurement on Power 9501 120 450xx

Leads, Voltage variations and-interruptions conform EN 61000-4-11

Appendix to ISO/lEG 17025 accreditation certificatenumber: L 240

of Thales Nederland B.V.Environmental Competence CentreHengelo

Valid from: 01-07-2008 till 26-05-2011 Replaces appendix dated: 26-05-2007

Shock and Vibration Test

Page 3 of 3

Nr. Material or Product Type of activity Internal referencenumber

29 Electronic and/or electric Conducted Emission measurement on Power 9501 120451 xxapparatus Leads, 150 kHz-30 MHz conformEN55011

30 Radiated Emission measurement, 9501 120 452xxE-field 30 MHz-1 GHz conform EN 55011

31 Conducted Emission measurement on Power 9501 120 453xx

Leads, 150 kHz-30 MHz conformEN55022

32 Radiated Emission measurement, 9501 120 454xx

E-field 30 MHz-1 GHz, Class B conformEN55022,classB

33 Electronic and/or method 514.4Vibration procedure I 9505 002 783xx

electric apparatus as method 516.4Shock procedure I and II conformMIL-STD-810Ewell as mechanical

34 apparatus method 514.5 Vibration procedure I 9505 002 783xx

method 516.5 Shock procedure I and II conformMIL-STD-810F

35 method 2040 Sine Vibrations test condition A-B-C 9505 002 783xx

method 2131:3Shock (specified pulse) conformMIL-STD-202Fmethod 214A Random Vibration test condition A-B-C

36 method 2040 Sine Vibrations test condition A-B-C 9505 002 783xx

method 213B Shock specified pulse conformMIL-STD-202Gmethod 214A Random Vibration test condition A-B-C

37 Publication 2-6 Sine Vibration testing 9505 002 783xx

Publication 2-27 Shock testing conformIEC68- IEC60068

Publication 2-29 Bump testing (DNV- 2002,GL-2003,Publication 2-34 Random Vibration testing LRTypeapprovalsystem2002Publication 2-64 Random Vibration testing ETSIEN300019-2-4)

38 Shock testing: 9505 002 783xx

Publication 3-1, Publication 3-2, Publication 3-3, conform IEC 721

Publication 3-4, Publication 3-5. (ETSIEN300019-2-4)

39 Vibration testing 9505 002 783xxconformIEC945-IEC 60945

40 Mechanical Vibrations of Shipboard Equipment 9505 002 783xxconform MIL-STD-167-1