application - alfanar · 2019-06-26 · gland plate for ease of cable entry fully shrouded busbars...

16

Upload: others

Post on 19-Mar-2020

11 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: APPLICATION - Alfanar · 2019-06-26 · gland plate for ease of cable entry fully shrouded busbars tin plated etp copper busbars without any joints polycarbonate for busbar support
Page 2: APPLICATION - Alfanar · 2019-06-26 · gland plate for ease of cable entry fully shrouded busbars tin plated etp copper busbars without any joints polycarbonate for busbar support

APPLICATION

KNOCKOUTS OF VARIOUS SIZESAND REMOVABLE TOP AND BOTTOMGLAND PLATE FOR EASE OF CABLE ENTRY

FULLY SHROUDED BUSBARS

TIN PLATED ETP COPPER BUSBARSWITHOUT ANY JOINTS

POLYCARBONATE FORBUSBAR SUPPORT AND INSULATION

AMPLE EARTH TERMINALS

ENCLOSURE MADE OF HIGH QUALITY ELECTRO-GALVANIZED STEEL SHEET

MAIN BREAKER

AMPLE NEUTRAL TERMINALS

SPACIOUS ENCLOSURE FOR EASY WIRING

MATT-FINISH POLYESTER POWDERCOATED IN RAL-7035 LIGHT GREY COLOUR

DEPTH OF PAN ASSEMBLY IS ADJUSTABLE

KEYHOLE FIXING FOREASE OF WALL MOUNTING

Figure 1

1

Made in KSAMade in KSA

Load Centers have been designed for safe and reliable distribution andcontrol of electrical power as service entrance in residential, commercial and lightindustrial premises. The Load Center type LA is available in Plug-in and Bolt-ondesigns for indoor and outdoor applications and also available with main as MCB,MCCB or ELCB.

Page 3: APPLICATION - Alfanar · 2019-06-26 · gland plate for ease of cable entry fully shrouded busbars tin plated etp copper busbars without any joints polycarbonate for busbar support

APPLICATION

KNOCKOUTS OF VARIOUS SIZESAND REMOVABLE TOP AND BOTTOMGLAND PLATE FOR EASE OF CABLE ENTRY

FULLY SHROUDED BUSBARS

TIN PLATED ETP COPPER BUSBARSWITHOUT ANY JOINTS

POLYCARBONATE FORBUSBAR SUPPORT AND INSULATION

AMPLE EARTH TERMINALS

ENCLOSURE MADE OF HIGH QUALITY ELECTRO-GALVANIZED STEEL SHEET

MAIN BREAKER

AMPLE NEUTRAL TERMINALS

SPACIOUS ENCLOSURE FOR EASY WIRING

MATT-FINISH POLYESTER POWDERCOATED IN RAL-7035 LIGHT GREY COLOUR

DEPTH OF PAN ASSEMBLY IS ADJUSTABLE

KEYHOLE FIXING FOREASE OF WALL MOUNTING

Figure 1

1

Made in KSAMade in KSA

Load Centers have been designed for safe and reliable distribution andcontrol of electrical power as service entrance in residential, commercial and lightindustrial premises. The Load Center type LA is available in Plug-in and Bolt-ondesigns for indoor and outdoor applications and also available with main as MCB,MCCB or ELCB.

Page 4: APPLICATION - Alfanar · 2019-06-26 · gland plate for ease of cable entry fully shrouded busbars tin plated etp copper busbars without any joints polycarbonate for busbar support

1- INDOOR TYPE Standard Load Center (Type LA)NEMA Compliant Distribution BoardNEMA Standards (UL 50 & UL 67)

Single-Phase LC With MCB Main 30-63 AF

Two-Phase LC With MCB Main 30-100 AF

Two-Phase LC Without Main

ORDERING NUMBER AND TYPENO. OFWAYS

ORDERING NUMBER AND TYPENO. OFWAYS

ORDERING NUMBER AND TYPENO. OFWAYS

Main Breaker: Ranges from 30-100AChange last four digits for required ratings and mountingFor example:42-0408060 Represents load center 8 way with 60A main flush mounted42-0408100S Represents load center 8 way with 100A main surface mounted

Busbar Rating: 100AChange last four digits for required ratings and mounting For example:42-0308000 Represents load center 8 way 100A flush mounted 42-0308000s Represents load center 8 way 100A surface mounted

Main Breaker: Ranges from 30-63AFor example:42-0604040IEC Represents load center 4 way with 40A main flush mounted42-0604063IECS Represents load center 4 way with 63A main surface mounted

327380380471522573624

250250250250250250250

220220220220220220220

95959595959595

303355355446522548599

42-0604063IEC42-0606063IEC42-0608063IEC42-0610063IEC42-0612063IEC42-0614063IEC42-0616063IEC

SURFACE42-0604063IECS42-0606063IECS42-0608063IECS42-0610063IECS42-0612063IECS42-0614063IECS42-0616063IECS

468

10121416

298350350441492543594

298350350441492543594

225225225225225225225

220220220220220220220

95959595959595

Figure 5

Figure 6

3

H330380380471

h298350350441

W250250250250

220220220220

98989898

w D468

10

FLUSH

FLUSH

42-040410042-040610042-040810042-0410100

SURFACE42-0404100S42-0406100S42-0408100S42-0410100S

H303355355446

h298350350441

225225225225

220220220220

98989898

W w D

H330330380420

h298298350390

W w D4

6

8

SURFACE42-0304000S42-0306000S42-0308000S42-0310000S

FLUSH42-030400042-030600042-030800042-0310000

H303303355395

h298298350390

W w D

FEATURES

SPECIFICATIONS

Made of high quality electro-galvanized steel sheet Tin plated ETP copper busbar without any jointsPolyester powder coating RAL-7035Available cable tie & cable holding for easy wiring installations

ITEM DESCRIPTION

StandardBusbar RatingBusbar TypeVoltage RatingNo. of Ways

Degree Of ProtectionEnclosure MaterialSteel ThicknessKnockout sizesEnclosure ColourPaint ThicknessMain Breaker (incomer)Terminal Capacity

BranchesNeutral Terminal Bar

Earth Terminal Bar

Rated Insulation VoltageAmbient Temperature

NEMA PB1*100 to 400A MAXETP copper flat fully shrouded120-440V AC 50/60 Hz3PH : 12,18, 24, 30, 36, 42, 48, 542PH : 4, 6, 8, 101PH : 4, 6, 8, 10, 12, 14,16IP40 (NEMA 1) & IP54 (NEMA 3R)Electro-galvanized steel sheet (corrosion resistant)Up to 1.2 mmSee details on page 10, Figure 27Polyester powder coated in RAL-7035 Grey colour70-90 micronsMCB, MCCB, ELCB, ISOLATOR & DIRECT CONNECTIONMCB Frame Size 100 A : 50 sq.mmMCCB Frame Size 100A : 95 sq.mmMCCB Frame Size 225A : 185 sq.mmMCCB Frame Size 250A : 185 sq.mmMCCB Frame Size 400A : 300+125 sq.mmELCB Frame Size 100A : 35 sq.mm1, 2 & 3 Pole Plug In MCBsIncoming Cable Lug :50,150 sq.mmOutgoing Terminals : 16 sq.mmNo. of Outgoing Terminals : Equivalent or more than No. of waysIncoming Cable Lug :50,150 sq.mmOutgoing Terminals :16 sq.mmNo. of Outgoing Terminals : Equivalent or more than No. of ways690 V AC50 ºC

2

Figure 4

Figure 3

Figure 2

1 POLE

H h W w D H h W w D1 POLE

1 POLE

10

225225225225

220220220220

220220220220

250250250250

98989898

98989898

Figure 8

Figure 7

* 'UL' compliance panels available upon request.

Page 5: APPLICATION - Alfanar · 2019-06-26 · gland plate for ease of cable entry fully shrouded busbars tin plated etp copper busbars without any joints polycarbonate for busbar support

1- INDOOR TYPE Standard Load Center (Type LA)NEMA Compliant Distribution BoardNEMA Standards (UL 50 & UL 67)

Single-Phase LC With MCB Main 30-63 AF

Two-Phase LC With MCB Main 30-100 AF

Two-Phase LC Without Main

ORDERING NUMBER AND TYPENO. OFWAYS

ORDERING NUMBER AND TYPENO. OFWAYS

ORDERING NUMBER AND TYPENO. OFWAYS

Main Breaker: Ranges from 30-100AChange last four digits for required ratings and mountingFor example:42-0408060 Represents load center 8 way with 60A main flush mounted42-0408100S Represents load center 8 way with 100A main surface mounted

Busbar Rating: 100AChange last four digits for required ratings and mounting For example:42-0308000 Represents load center 8 way 100A flush mounted 42-0308000s Represents load center 8 way 100A surface mounted

Main Breaker: Ranges from 30-63AFor example:42-0604040IEC Represents load center 4 way with 40A main flush mounted42-0604063IECS Represents load center 4 way with 63A main surface mounted

327380380471522573624

250250250250250250250

220220220220220220220

95959595959595

303355355446522548599

42-0604063IEC42-0606063IEC42-0608063IEC42-0610063IEC42-0612063IEC42-0614063IEC42-0616063IEC

SURFACE42-0604063IECS42-0606063IECS42-0608063IECS42-0610063IECS42-0612063IECS42-0614063IECS42-0616063IECS

468

10121416

298350350441492543594

298350350441492543594

225225225225225225225

220220220220220220220

95959595959595

Figure 5

Figure 6

3

H330380380471

h298350350441

W250250250250

220220220220

98989898

w D468

10

FLUSH

FLUSH

42-040410042-040610042-040810042-0410100

SURFACE42-0404100S42-0406100S42-0408100S42-0410100S

H303355355446

h298350350441

225225225225

220220220220

98989898

W w D

H330330380420

h298298350390

W w D4

6

8

SURFACE42-0304000S42-0306000S42-0308000S42-0310000S

FLUSH42-030400042-030600042-030800042-0310000

H303303355395

h298298350390

W w D

FEATURES

SPECIFICATIONS

Made of high quality electro-galvanized steel sheet Tin plated ETP copper busbar without any jointsPolyester powder coating RAL-7035Available cable tie & cable holding for easy wiring installations

ITEM DESCRIPTION

StandardBusbar RatingBusbar TypeVoltage RatingNo. of Ways

Degree Of ProtectionEnclosure MaterialSteel ThicknessKnockout sizesEnclosure ColourPaint ThicknessMain Breaker (incomer)Terminal Capacity

BranchesNeutral Terminal Bar

Earth Terminal Bar

Rated Insulation VoltageAmbient Temperature

NEMA PB1*100 to 400A MAXETP copper flat fully shrouded120-440V AC 50/60 Hz3PH : 12,18, 24, 30, 36, 42, 48, 542PH : 4, 6, 8, 101PH : 4, 6, 8, 10, 12, 14,16IP40 (NEMA 1) & IP54 (NEMA 3R)Electro-galvanized steel sheet (corrosion resistant)Up to 1.2 mmSee details on page 10, Figure 27Polyester powder coated in RAL-7035 Grey colour70-90 micronsMCB, MCCB, ELCB, ISOLATOR & DIRECT CONNECTIONMCB Frame Size 100 A : 50 sq.mmMCCB Frame Size 100A : 95 sq.mmMCCB Frame Size 225A : 185 sq.mmMCCB Frame Size 250A : 185 sq.mmMCCB Frame Size 400A : 300+125 sq.mmELCB Frame Size 100A : 35 sq.mm1, 2 & 3 Pole Plug In MCBsIncoming Cable Lug :50,150 sq.mmOutgoing Terminals : 16 sq.mmNo. of Outgoing Terminals : Equivalent or more than No. of waysIncoming Cable Lug :50,150 sq.mmOutgoing Terminals :16 sq.mmNo. of Outgoing Terminals : Equivalent or more than No. of ways690 V AC50 ºC

2

Figure 4

Figure 3

Figure 2

1 POLE

H h W w D H h W w D1 POLE

1 POLE

10

225225225225

220220220220

220220220220

250250250250

98989898

98989898

Figure 8

Figure 7

* 'UL' compliance panels available upon request.

Page 6: APPLICATION - Alfanar · 2019-06-26 · gland plate for ease of cable entry fully shrouded busbars tin plated etp copper busbars without any joints polycarbonate for busbar support

Three-Phase LC With MCB Main 30-100 AF

Three-Phase LC With MCCB Main 30-100 AF

Three-Phase LC With MCCB Main 125-225 AF

ORDERING NUMBER AND TYPENO. OF WAYS

ORDERING NUMBER AND TYPENO. OF WAYS

ORDERING NUMBER AND TYPENO. OF WAYS

Main Breaker: Ranges from 30-100AChange last four digits for required ratings and mountingFor example:

42-12060 Represents load center 12 way with 60A main flush mounted42-12100S Represents load center 12 way with 100A main surface mounted

Main Breaker: Ranges from 30-100AChange last four digits for required ratings and mounting For example:42-L12060 Represents load center 12 way with 60A main flush mounted42-L12100S Represents load center 12 way with 100A main surface mounted

Main Breaker: Ranges from 125-225AChange last four digits for required ratings and mountingFor example:42-L42125 Represents load center 42 way with 125A main flush mounted42-L42225S Represents load center 42 way with 225A main surface mounted

69121824303642

23468

101214

FLUSH42-0610042-0910042-1210042-1810042-2410042-3010042-3610042-42100

SURFACE42-06100S42-09100S42-12100S42-18100S42-24100S42-30100S42-36100S42-42100S

FLUSH42-L12100

42-L18100

42-L24100

42-L30100

42-L36100

42-L42100

42-L12100S

42-L18100S

42-L24100S

42-L30100S

42-L36100S

42-L42100S

SURFACE

FLUSH42-L1222542-L1822542-L2422542-L3022542-L3622542-L4222542-L48225

SURFACE42-L12225S42-L18225S42-L24225S42-L30225S42-L36225S42-L42225S42-L48225S

H

445332542618697773878960

W

370370367367367370370370

Dw

343343343343343343343343

105105105105105105105105

370370370370370370

370370370370370370370

343343343343343343343

105105105105105105105

343343343343343343343

105105105105105105105

105105105105105105

343343343343343343343343

105105105105105105105105

343343343343343343

343343343343343343

355355355355355355

355355355355355355355

105105105105105105

h

415302515591667743848930

H

430317527603682758863945

W

355355352352352355355355

Dwh

415302515591667743848930

H620700773878960

1040

W Dwh590670743848930

1010

H605685758863945

1025

W Dwh590670743848930

1010

H

620700773878960

10401120

W Dwh

590670743848930

10101090

H

605685758863945

10251105

W Dwh

590670743848930

10101090

Figure 10

Figure 124

Three-Phase LC With MCCB Main 250 A

Three-Phase LC With MCCB Main 300-400 AF

One-Phase LC With 2 Pole ELCB Main

Main Breaker: Ranges from 300-400AChange last four digits for required ratings and mountingFor example:42-42300 Represents load center 42 way with 300A main flush mounted42-42400S Represents load center 42 way with 400A main surface mounted

Main Breaker: 250A Change last four digits for required ratings and mountingFor example:42-42250 Represents load center 42 way with 250A main flush mounted42-42250S Represents load center 42 way with 250A main surface mounted

AVAILABLE RANGE:1- 2P, 63A, 30mA2- 2P, 63A, 100mA3- 2P, 63A, 300mA*4- 2P, 63A, 500mA*

*Will be manufactured on special request

46 - E 061 063 030 S

Select The Main Sensitivity As Mentioned Above

TYPE SURFACE

SENSITIVITY

RATING

NO. OF WAYS

ONE PHASE

NO. OF WAYS

ORDERING NUMBER AND TYPE

ORDERING NUMBER AND TYPE

NO. OF WAYS

ORDERING NUMBER AND TYPENO. OF WAYS

h896

972

1048

1124

1200

1275

430

430

430

430

430

430

400

400

400

400

400

400

400

400

400

400

400

400

415

415

415

415

415

415

140

140

140

140

140

140

140

140

140

140

140

140

1 POLE18

24

30

36

42

48

3 POLE1 POLE 3 POLE

1 POLE 3 POLE

1 POLE 3 POLE

6

8

10

12

14

16

FLUSH42-18250

42-24250

42-30250

42-36250

42-42250

42-48250

42-18250S

42-24250S

42-30250S

42-36250S

42-42250S

42-48250S

SURFACE

243036424854

81012141618

FLUSH42-2440042-3040042-3640042-4240042-4840042-54400

42-24400S42-30400S42-36400S42-42400S42-48400S42-54400S

SURFACE

FLUSH SURFACE468

10121416

46-E10406303046-E10606303046-E10806303046-E11006303046-E11206303046-E11406303046-E116063030

46-E104063030S46-E106063030S46-E108063030S46-E110063030S46-E112063030S46-E114063030S46-E116063030S

W w DH926

1002

1078

1154

1230

1305

h896

972

1048

1124

1200

1275

W w DH911

987

1063

1139

1215

1290

h115612321308138414601540

530530530530530530

515515515515515515

500500500500500500

160160160160160160

500500500500500500

160160160160160160

W w DH118612621338141414901570

h115612321308138414601540

W w DH117112471323139914751555

h W w DH h W w DH

Figure 13

Figure 14

Figure 15

5

INDOOR TYPE

1 POLE

1 POLE

3 POLE

121824303642

468

101214

12182430364248

468

10121416

327380380471522573624

250250250250250250250

220220220220220220220

95959595959595

303355355446522548599

298350350441492543594

298350350441492543594

225225225225225225225

220220220220220220220

95959595959595

Figure 11

Figure 9

Page 7: APPLICATION - Alfanar · 2019-06-26 · gland plate for ease of cable entry fully shrouded busbars tin plated etp copper busbars without any joints polycarbonate for busbar support

Three-Phase LC With MCB Main 30-100 AF

Three-Phase LC With MCCB Main 30-100 AF

Three-Phase LC With MCCB Main 125-225 AF

ORDERING NUMBER AND TYPENO. OF WAYS

ORDERING NUMBER AND TYPENO. OF WAYS

ORDERING NUMBER AND TYPENO. OF WAYS

Main Breaker: Ranges from 30-100AChange last four digits for required ratings and mountingFor example:

42-12060 Represents load center 12 way with 60A main flush mounted42-12100S Represents load center 12 way with 100A main surface mounted

Main Breaker: Ranges from 30-100AChange last four digits for required ratings and mounting For example:42-L12060 Represents load center 12 way with 60A main flush mounted42-L12100S Represents load center 12 way with 100A main surface mounted

Main Breaker: Ranges from 125-225AChange last four digits for required ratings and mountingFor example:42-L42125 Represents load center 42 way with 125A main flush mounted42-L42225S Represents load center 42 way with 225A main surface mounted

69121824303642

23468101214

FLUSH42-0610042-0910042-1210042-1810042-2410042-3010042-3610042-42100

SURFACE42-06100S42-09100S42-12100S42-18100S42-24100S42-30100S42-36100S42-42100S

FLUSH42-L12100

42-L18100

42-L24100

42-L30100

42-L36100

42-L42100

42-L12100S

42-L18100S

42-L24100S

42-L30100S

42-L36100S

42-L42100S

SURFACE

FLUSH42-L1222542-L1822542-L2422542-L3022542-L3622542-L4222542-L48225

SURFACE42-L12225S42-L18225S42-L24225S42-L30225S42-L36225S42-L42225S42-L48225S

H

445332542618697773878960

W

370370367367367370370370

Dw

343343343343343343343343

105105105105105105105105

370370370370370370

370370370370370370370

343343343343343343343

105105105105105105105

343343343343343343343

105105105105105105105

105105105105105105

343343343343343343343343

105105105105105105105105

343343343343343343

343343343343343343

355355355355355355

355355355355355355355

105105105105105105

h

415302515591667743848930

H

430317527603682758863945

W

355355352352352355355355

Dwh

415302515591667743848930

H620700773878960

1040

W Dwh590670743848930

1010

H605685758863945

1025

W Dwh590670743848930

1010

H

620700773878960

10401120

W Dwh

590670743848930

10101090

H

605685758863945

10251105

W Dwh

590670743848930

10101090

Figure 10

Figure 124

Three-Phase LC With MCCB Main 250 A

Three-Phase LC With MCCB Main 300-400 AF

One-Phase LC With 2 Pole ELCB Main

Main Breaker: Ranges from 300-400AChange last four digits for required ratings and mountingFor example:42-42300 Represents load center 42 way with 300A main flush mounted42-42400S Represents load center 42 way with 400A main surface mounted

Main Breaker: 250A Change last four digits for required ratings and mountingFor example:42-42250 Represents load center 42 way with 250A main flush mounted42-42250S Represents load center 42 way with 250A main surface mounted

AVAILABLE RANGE:1- 2P, 63A, 30mA2- 2P, 63A, 100mA3- 2P, 63A, 300mA*4- 2P, 63A, 500mA*

*Will be manufactured on special request

46 - E 061 063 030 S

Select The Main Sensitivity As Mentioned Above

TYPE SURFACE

SENSITIVITY

RATING

NO. OF WAYS

ONE PHASE

NO. OF WAYS

ORDERING NUMBER AND TYPE

ORDERING NUMBER AND TYPE

NO. OF WAYS

ORDERING NUMBER AND TYPENO. OF WAYS

h896

972

1048

1124

1200

1275

430

430

430

430

430

430

400

400

400

400

400

400

400

400

400

400

400

400

415

415

415

415

415

415

140

140

140

140

140

140

140

140

140

140

140

140

1 POLE18

24

30

36

42

48

3 POLE1 POLE 3 POLE

1 POLE 3 POLE

1 POLE 3 POLE

6

8

10

12

14

16

FLUSH42-18250

42-24250

42-30250

42-36250

42-42250

42-48250

42-18250S

42-24250S

42-30250S

42-36250S

42-42250S

42-48250S

SURFACE

243036424854

81012141618

FLUSH42-2440042-3040042-3640042-4240042-4840042-54400

42-24400S42-30400S42-36400S42-42400S42-48400S42-54400S

SURFACE

FLUSH SURFACE468

10121416

46-E10406303046-E10606303046-E10806303046-E11006303046-E11206303046-E11406303046-E116063030

46-E104063030S46-E106063030S46-E108063030S46-E110063030S46-E112063030S46-E114063030S46-E116063030S

W w DH926

1002

1078

1154

1230

1305

h896

972

1048

1124

1200

1275

W w DH911

987

1063

1139

1215

1290

h115612321308138414601540

530530530530530530

515515515515515515

500500500500500500

160160160160160160

500500500500500500

160160160160160160

W w DH118612621338141414901570

h115612321308138414601540

W w DH117112471323139914751555

h W w DH h W w DH

Figure 13

Figure 14

Figure 15

5

INDOOR TYPE

1 POLE

1 POLE

3 POLE

121824303642

468101214

12182430364248

46810121416

327380380471522573624

250250250250250250250

220220220220220220220

95959595959595

303355355446522548599

298350350441492543594

298350350441492543594

225225225225225225225

220220220220220220220

95959595959595

Figure 11

Figure 9

Page 8: APPLICATION - Alfanar · 2019-06-26 · gland plate for ease of cable entry fully shrouded busbars tin plated etp copper busbars without any joints polycarbonate for busbar support

46 - E 3 12 063 030 S

TYPE SURFACE

SENSITIVITY

RATING

NO. OF WAYS

THREE PHASE

46 - L 06 06 20 20 S100

3 POLE1 POLE FLUSH46-E312063030

46-E318063030

46-E324063030

46-E330063030

46-E336063030

46-E342063030

46-E312063030S

46-E318063030S

46-E324063030S

46-E330063030S

46-E336063030S

46-E342063030S

SURFACE

3 POLE1 POLE FLUSH SURFACE46-I060610020

46-I120610020

46-I121210020

46-I181210020

46-I181810020

46-I241810020

46-I060610020S

46-I120610020S

46-I121210020S

46-I181210020S

46-I181810020S

46-I241810020S

46-I06061002020

46-I12061002020

46-I12121002020

46-I18121002020

46-I18181002020

46-I24181002020

46-I06061002020S

46-I12061002020S

46-I12121002020S

46-I18121002020S

46-I18181002020S

46-I24181002020S

h515

591

667

743

848

930

W367

367

367

370

370

370

343

343

343

343

343

343

105

105

105

105

105

105

105

105

105

105

105

105

w DH542

618

697

773

878

960

h515

591

667

743

848

930

352

352

352

355

355

355

W w DH527

603

682

758

863

945

h590

666

750

818

898

974

370

370

370

370

370

370

343

343

343

343

343

343

105

105

105

105

105

105

343

343

343

343

343

343

343

343

343

343

343

343

105

105

105

105

105

105

355

355

355

355

355

355

W w DH620

696

780

848

928

1004

590

666

750

818

898

974

370

370

370

370

370

370

343

343

343

343

343

343

105

105

105

105

105

105

620

696

780

848

928

1004

h590

666

750

818

898

974

W w DH605

681

765

833

913

989

343

343

343

343

343

343

105

105

105

105

105

105

355

355

355

355

355

355

590

666

750

818

898

974

605

681

765

833

913

989

h W w DH h W w DH

Select The Main Rating and Sensitivity As Mentioned Above

AVAILABLE RANGE:1- 4P, 63A, 30mA2- 4P, 63A,100mA3- 4P, 63A, 300mA*4- 4P, 63A, 500mA*5- 4P, 100A, 30mA6- 4P, 100A,100mA7- 4P, 100A, 300mA*8- 4P, 100A, 500mA**Will be manufactured on special request

Three-Phase 2 Sections LC With 3 Pole Main Isolator Or MCB And One Sections Protected By 4 Pole ELCB

Three-Phase 2 Sections LC With 3 Pole Main Isolator Or MCB And Both Sections Protected By 2 Nos. Of 4 Pole ELCBs

Three-Phase LC With 4 Pole ELCB Main

3 POLE1 POLE FLUSH SURFACE

Figure16

Figure20

6

ORDERING NUMBER AND TYPENO. OF WAYS

ORDERING NUMBER AND TYPEORDERING NUMBER AND TYPE

7

CODE # CODE #063-100030-100030-100125-225

20304050

63, 100A ISOLATOR “I”FOR 30, 40, 50, 60, 70, 100A MCB “T”FOR 30, 40, 50, 60, 75, 100A MCCB “L”FOR 125. 150. 175. 200. 225A MCCB “L”

RATING RATING63A 30mA100A 30mA63A 100mA

100A 100mA

46 - 100L 06 06 20 S

Please Select Your Product As Mentioned Above

Type Surface

* Main Breaker RatingNo. Of Ways Section-2No. Of Ways Section-1

Main Breaker Type -‘’ L’’ For MCCB ‘’ T ‘’ For MCB, ‘’ I ‘’ For Isolator

** ELCB Rating

Type Surface

* Main Breaker RatingNo. Of Ways Section-2No. Of Ways Section-1

Main Breaker Type”L” For MCCB, “T” For MCB, “I” For Isolator

ELCB Rating Section-2

** ELCB Rating Section-1

* MAIN BREAKER RATING ** ELCB RATING

CODE # CODE #063-100030-100030-100125-225

20304050

63, 100A ISOLATOR “I” FOR 30, 40,50,60,70,100A MCB “T”FOR 30, 40,50,60,75,100A MCCB “L”FOR 125,150,175,200,225A MCCB “L”

RATING RATING63A 30mA100A 30mA63A 100mA

100A 100mA

Please Select Your Product As Mentioned Above

* MAIN BREAKER RATING * MAIN BREAKER RATING** ELCB RATING

468101214

121824303642

6+612+6

12+1218+1218+1824+18

2+24+24+46+46+68+6

3 POLE1 POLE FLUSH SURFACE46-L060610020

46-L120610020

46-L121210020

46-L181210020

46-L181810020

46-L241810020

46-L060610020S

46-L120610020S

46-L121210020S

46-L181210020S

46-L181810020S

46-L241810020S

h786

862

938

1014

1090

1166

105

105

105

105

105

105

105

105

105

105

105

105

W w DH816

892

968

1044

1120

1196

h W w DH

Three-Phase 2 Sections LC With 3 Pole Main MCCB And One Sections Protected By 4 Pole ELCB

ORDERING NUMBER AND TYPE

6+612+6

12+1218+1218+1824+18

2+24+24+46+46+68+6

6+612+612+1218+1218+1824+18

2+24+24+46+46+68+6

46-L06061002020

46-L12061002020

46-L12121002020

46-L18121002020

46-L18181002020

46-L24181002020

46-L06061002020S

46-L12061002020S

46-L12121002020S

46-L18121002020S

46-L18181002020S

46-L24181002020S

786

862

938

1014

1090

1166

430

430

430

430

430

430

400

400

400

400

400

400

430

430

430

430

430

430

400

400

400

400

400

400

105

105

105

105

105

105

816

892

968

1044

1120

1196

400

400

400

400

400

400

105

105

105

105

105

105

414

414

414

414

414

414

786

862

938

1014

1090

1166

800

876

952

1028

1104

1180

400

400

400

400

400

400

414

414

414

414

414

414

786

862

938

1014

1090

1166

800

876

952

1028

1104

1180

h W w DH h W w DH

Three-Phase 2 Sections LC With 3 Pole Main MCCB And Both Sections Protected By 2 Nos. Of 4 Pole ELCBs

3 POLE1 POLE FLUSH SURFACE

ORDERING NUMBER AND TYPENO. OF WAYS NO. OF WAYS

NO. OF WAYSNO. OF WAYS

6+612+612+1218+1218+1824+18

2+24+24+46+46+68+6

INDOOR TYPE

Figure18

Figure17 Figure19

Page 9: APPLICATION - Alfanar · 2019-06-26 · gland plate for ease of cable entry fully shrouded busbars tin plated etp copper busbars without any joints polycarbonate for busbar support

46 - E 3 12 063 030 S

TYPE SURFACE

SENSITIVITY

RATING

NO. OF WAYS

THREE PHASE

46 - L 06 06 20 20 S100

3 POLE1 POLE FLUSH46-E312063030

46-E318063030

46-E324063030

46-E330063030

46-E336063030

46-E342063030

46-E312063030S

46-E318063030S

46-E324063030S

46-E330063030S

46-E336063030S

46-E342063030S

SURFACE

3 POLE1 POLE FLUSH SURFACE46-I060610020

46-I120610020

46-I121210020

46-I181210020

46-I181810020

46-I241810020

46-I060610020S

46-I120610020S

46-I121210020S

46-I181210020S

46-I181810020S

46-I241810020S

46-I06061002020

46-I12061002020

46-I12121002020

46-I18121002020

46-I18181002020

46-I24181002020

46-I06061002020S

46-I12061002020S

46-I12121002020S

46-I18121002020S

46-I18181002020S

46-I24181002020S

h515

591

667

743

848

930

W367

367

367

370

370

370

343

343

343

343

343

343

105

105

105

105

105

105

105

105

105

105

105

105

w DH542

618

697

773

878

960

h515

591

667

743

848

930

352

352

352

355

355

355

W w DH527

603

682

758

863

945

h590

666

750

818

898

974

370

370

370

370

370

370

343

343

343

343

343

343

105

105

105

105

105

105

343

343

343

343

343

343

343

343

343

343

343

343

105

105

105

105

105

105

355

355

355

355

355

355

W w DH620

696

780

848

928

1004

590

666

750

818

898

974

370

370

370

370

370

370

343

343

343

343

343

343

105

105

105

105

105

105

620

696

780

848

928

1004

h590

666

750

818

898

974

W w DH605

681

765

833

913

989

343

343

343

343

343

343

105

105

105

105

105

105

355

355

355

355

355

355

590

666

750

818

898

974

605

681

765

833

913

989

h W w DH h W w DH

Select The Main Rating and Sensitivity As Mentioned Above

AVAILABLE RANGE:1- 4P, 63A, 30mA2- 4P, 63A,100mA3- 4P, 63A, 300mA*4- 4P, 63A, 500mA*5- 4P, 100A, 30mA6- 4P, 100A,100mA7- 4P, 100A, 300mA*8- 4P, 100A, 500mA**Will be manufactured on special request

Three-Phase 2 Sections LC With 3 Pole Main Isolator Or MCB And One Sections Protected By 4 Pole ELCB

Three-Phase 2 Sections LC With 3 Pole Main Isolator Or MCB And Both Sections Protected By 2 Nos. Of 4 Pole ELCBs

Three-Phase LC With 4 Pole ELCB Main

3 POLE1 POLE FLUSH SURFACE

Figure16

Figure20

6

ORDERING NUMBER AND TYPENO. OF WAYS

ORDERING NUMBER AND TYPEORDERING NUMBER AND TYPE

7

CODE # CODE #063-100030-100030-100125-225

20304050

63, 100A ISOLATOR “I”FOR 30, 40, 50, 60, 70, 100A MCB “T”FOR 30, 40, 50, 60, 75, 100A MCCB “L”FOR 125. 150. 175. 200. 225A MCCB “L”

RATING RATING63A 30mA100A 30mA63A 100mA

100A 100mA

46 - 100L 06 06 20 S

Please Select Your Product As Mentioned Above

Type Surface

* Main Breaker RatingNo. Of Ways Section-2No. Of Ways Section-1

Main Breaker Type -‘’ L’’ For MCCB ‘’ T ‘’ For MCB, ‘’ I ‘’ For Isolator

** ELCB Rating

Type Surface

* Main Breaker RatingNo. Of Ways Section-2No. Of Ways Section-1

Main Breaker Type”L” For MCCB, “T” For MCB, “I” For Isolator

ELCB Rating Section-2

** ELCB Rating Section-1

* MAIN BREAKER RATING ** ELCB RATING

CODE # CODE #063-100030-100030-100125-225

20304050

63, 100A ISOLATOR “I” FOR 30, 40,50,60,70,100A MCB “T”FOR 30, 40,50,60,75,100A MCCB “L”FOR 125,150,175,200,225A MCCB “L”

RATING RATING63A 30mA100A 30mA63A 100mA

100A 100mA

Please Select Your Product As Mentioned Above

* MAIN BREAKER RATING * MAIN BREAKER RATING** ELCB RATING

468

101214

121824303642

6+612+6

12+1218+1218+1824+18

2+24+24+46+46+68+6

3 POLE1 POLE FLUSH SURFACE46-L060610020

46-L120610020

46-L121210020

46-L181210020

46-L181810020

46-L241810020

46-L060610020S

46-L120610020S

46-L121210020S

46-L181210020S

46-L181810020S

46-L241810020S

h786

862

938

1014

1090

1166

105

105

105

105

105

105

105

105

105

105

105

105

W w DH816

892

968

1044

1120

1196

h W w DH

Three-Phase 2 Sections LC With 3 Pole Main MCCB And One Sections Protected By 4 Pole ELCB

ORDERING NUMBER AND TYPE

6+612+6

12+1218+1218+1824+18

2+24+24+46+46+68+6

6+612+6

12+1218+1218+1824+18

2+24+24+46+46+68+6

46-L06061002020

46-L12061002020

46-L12121002020

46-L18121002020

46-L18181002020

46-L24181002020

46-L06061002020S

46-L12061002020S

46-L12121002020S

46-L18121002020S

46-L18181002020S

46-L24181002020S

786

862

938

1014

1090

1166

430

430

430

430

430

430

400

400

400

400

400

400

430

430

430

430

430

430

400

400

400

400

400

400

105

105

105

105

105

105

816

892

968

1044

1120

1196

400

400

400

400

400

400

105

105

105

105

105

105

414

414

414

414

414

414

786

862

938

1014

1090

1166

800

876

952

1028

1104

1180

400

400

400

400

400

400

414

414

414

414

414

414

786

862

938

1014

1090

1166

800

876

952

1028

1104

1180

h W w DH h W w DH

Three-Phase 2 Sections LC With 3 Pole Main MCCB And Both Sections Protected By 2 Nos. Of 4 Pole ELCBs

3 POLE1 POLE FLUSH SURFACE

ORDERING NUMBER AND TYPENO. OF WAYS NO. OF WAYS

NO. OF WAYSNO. OF WAYS

6+612+6

12+1218+1218+1824+18

2+24+24+46+46+68+6

INDOOR TYPE

Figure18

Figure17 Figure19

Page 10: APPLICATION - Alfanar · 2019-06-26 · gland plate for ease of cable entry fully shrouded busbars tin plated etp copper busbars without any joints polycarbonate for busbar support

Three-Phase LC With MCCB Main 125-225 AF

Main Breaker: Ranges from 125-225AChange last three digits for required ratingsFor example:42-WPL42125 Represents load centr 42 way with 125A main42-WPL42225 Represents load center 42 way with 225A main

Main Breaker: 250AChange last three digits for required ratingsFor example:42-WP42250 Represents load center 42 way with 250A main42-WP48250 Represents load center 48 way with 250A main

Main Breaker: Ranges from 300-400AChange last three digits for required ratingFor example:42-WP42300 Represents load center 42 way with 300A main42-WP42400 Represents load center 42 way with 400A main

Three-Phase LC With MCCB Main 250 A

Three-Phase LC With MCCB Main 300-400 AF

ORDERING DETAILS AND TYPENO. OF WAYS

ORDERING DETAILS AND TYPENO. OF WAYS

ORDERING DETAILS AND TYPENO. OF WAYS

Figure 25

Figure 26

42-WPL1222542-WPL1822542-WPL2422542-WPL3022542-WPL3622542-WPL4222542-WPL48225

2430364248

810121416

42-WP2425042-WP3025042-WP3625042-WP4225042-WP48250

30364248

10121416

42-WP3040042-WP3640042-WP4240042-WP48400

H615692768845921998

1074

350350350350350350350

160160160160160160160

W D

H800877953

10301106

400400400400400

180180180180180

W D

H

1232130913851462

500500500500

200200200200

W D

CODE

CODE

CODE

3 POLE1 POLE

3 POLE1 POLE

3 POLE1 POLE

Main Breaker: Ranges from 30-100AChange last three digits for required ratingsFor example:42-WP12030 Represents load center 12 way with 30A main42-WP12100 Represents load center 12 way with 100A main

Main Breaker: Ranges from 30-100AChange last three digits for required ratingsFor example:42-WPL18030 Represents load center 18 way with 30A main42-WPL18100 Represents load center 18 way with 100A main

8

Figure 22

ORDERING NUMBER AND TYPENO. OF WAYS

ORDERING NUMBER AND TYPENO. OF WAYS

Three-Phase LC With MCB Main 30-100 AF

Three-Phase LC With MCCB Main 30-100 AF

42-WPL1210042-WPL1810042-WPL2410042-WPL3010042-WPL3610042-WPL42100

H

515592668745821898

350350350350350350

160160160160160160

350350350350350350

160160160160160160

W DCODE

42-WP1210042-WP1810042-WP2410042-WP3010042-WP3610042-WP42100

468

101214

121824303642

468101214

121824303642

H

555632708785861938

W DCODE

9

2- OUTDOOR TYPE

3 POLE1 POLE

3 POLE1 POLE

468

10121416

12182430364248

Figure 21

Figure 23

Figure 24

Page 11: APPLICATION - Alfanar · 2019-06-26 · gland plate for ease of cable entry fully shrouded busbars tin plated etp copper busbars without any joints polycarbonate for busbar support

Three-Phase LC With MCCB Main 125-225 AF

Main Breaker: Ranges from 125-225AChange last three digits for required ratingsFor example:42-WPL42125 Represents load centr 42 way with 125A main42-WPL42225 Represents load center 42 way with 225A main

Main Breaker: 250AChange last three digits for required ratingsFor example:42-WP42250 Represents load center 42 way with 250A main42-WP48250 Represents load center 48 way with 250A main

Main Breaker: Ranges from 300-400AChange last three digits for required ratingFor example:42-WP42300 Represents load center 42 way with 300A main42-WP42400 Represents load center 42 way with 400A main

Three-Phase LC With MCCB Main 250 A

Three-Phase LC With MCCB Main 300-400 AF

ORDERING DETAILS AND TYPENO. OF WAYS

ORDERING DETAILS AND TYPENO. OF WAYS

ORDERING DETAILS AND TYPENO. OF WAYS

Figure 25

Figure 26

42-WPL1222542-WPL1822542-WPL2422542-WPL3022542-WPL3622542-WPL4222542-WPL48225

2430364248

810121416

42-WP2425042-WP3025042-WP3625042-WP4225042-WP48250

30364248

10121416

42-WP3040042-WP3640042-WP4240042-WP48400

H615692768845921998

1074

350350350350350350350

160160160160160160160

W D

H800877953

10301106

400400400400400

180180180180180

W D

H

1232130913851462

500500500500

200200200200

W D

CODE

CODE

CODE

3 POLE1 POLE

3 POLE1 POLE

3 POLE1 POLE

Main Breaker: Ranges from 30-100AChange last three digits for required ratingsFor example:42-WP12030 Represents load center 12 way with 30A main42-WP12100 Represents load center 12 way with 100A main

Main Breaker: Ranges from 30-100AChange last three digits for required ratingsFor example:42-WPL18030 Represents load center 18 way with 30A main42-WPL18100 Represents load center 18 way with 100A main

8

Figure 22

ORDERING NUMBER AND TYPENO. OF WAYS

ORDERING NUMBER AND TYPENO. OF WAYS

Three-Phase LC With MCB Main 30-100 AF

Three-Phase LC With MCCB Main 30-100 AF

42-WPL1210042-WPL1810042-WPL2410042-WPL3010042-WPL3610042-WPL42100

H

515592668745821898

350350350350350350

160160160160160160

350350350350350350

160160160160160160

W DCODE

42-WP1210042-WP1810042-WP2410042-WP3010042-WP3610042-WP42100

468

101214

121824303642

468101214

121824303642

H

555632708785861938

W DCODE

9

2- OUTDOOR TYPE

3 POLE1 POLE

3 POLE1 POLE

468

10121416

12182430364248

Figure 21

Figure 23

Figure 24

Page 12: APPLICATION - Alfanar · 2019-06-26 · gland plate for ease of cable entry fully shrouded busbars tin plated etp copper busbars without any joints polycarbonate for busbar support

A- O21/O27B- O38.5/O44C- O19/O25D- O44/O54.5/O64E- O23/O28/O33F- O44/O50/O62G- WALL MOUNTING EMBOSS WITH KEY HOLE - 4 Nos.

10

LA KNOCKOUTS

DOUBLE KNOCKOUT -2 Nos.DOUBLE KNOCKOUT - 6 NosTRIPLE KNOCKOUT -16 Nos.TRIPLE KNOCKOUT - 4 Nos.TRIPLE KNOCKOUT - 4 Nos.TRIPLE KNOCKOUT - 2 Nos.

Figure 27

LA 3 PH 100A MCB 12W - 42W

TESTING

All load centers type (LA) are type tested for complete sequence as per international standards.

Each of our products under go strict quality control check and is routinely checked for:

Dielectric Test : A high voltage routine test

Electrical Continuity Test : To confirm correct assembly & operation

Insulation Resistance Test : To ensure high insulation resistance

11

123456

12345

Dimensions

ELETRA MOULDED CASE CIRCUIT BREAKER ELA

ELETRA MOULDED CASE CIRCUIT BREAKER ELB

Description MCCB 3P(ELA) 30A MCCB 3P(ELA) 40A MCCB 3P(ELA) 50A MCCB 3P(ELA) 60A MCCB 3P(ELA) 75A MCCB 3P(ELA)100A

MCCB 3P(ELB) 125A MCCB 3P(ELB) 150A MCCB 3P(ELB) 175A MCCB 3P(ELB) 200A MCCB 3P(ELB) 225A

S/NO.

DescriptionS/NO.

Figure 28

Figure 29

MOUNTING

Moulded Case Circuit Breaker (MCCB)

Notes:All dimension are in mmThe details in this drawing indicate dimensions and knockout positions for one Load Center. Knockout details for other Load Center types, shown in this catalogue, are available on request

Page 13: APPLICATION - Alfanar · 2019-06-26 · gland plate for ease of cable entry fully shrouded busbars tin plated etp copper busbars without any joints polycarbonate for busbar support

A- O21/O27B- O38.5/O44C- O19/O25D- O44/O54.5/O64E- O23/O28/O33F- O44/O50/O62G- WALL MOUNTING EMBOSS WITH KEY HOLE - 4 Nos.

10

LA KNOCKOUTS

DOUBLE KNOCKOUT -2 Nos.DOUBLE KNOCKOUT - 6 NosTRIPLE KNOCKOUT -16 Nos.TRIPLE KNOCKOUT - 4 Nos.TRIPLE KNOCKOUT - 4 Nos.TRIPLE KNOCKOUT - 2 Nos.

Figure 27

LA 3 PH 100A MCB 12W - 42W

TESTING

All load centers type (LA) are type tested for complete sequence as per international standards.

Each of our products under go strict quality control check and is routinely checked for:

Dielectric Test : A high voltage routine test

Electrical Continuity Test : To confirm correct assembly & operation

Insulation Resistance Test : To ensure high insulation resistance

11

123456

12345

Dimensions

ELETRA MOULDED CASE CIRCUIT BREAKER ELA

ELETRA MOULDED CASE CIRCUIT BREAKER ELB

Description MCCB 3P(ELA) 30A MCCB 3P(ELA) 40A MCCB 3P(ELA) 50A MCCB 3P(ELA) 60A MCCB 3P(ELA) 75A MCCB 3P(ELA)100A

MCCB 3P(ELB) 125A MCCB 3P(ELB) 150A MCCB 3P(ELB) 175A MCCB 3P(ELB) 200A MCCB 3P(ELB) 225A

S/NO.

DescriptionS/NO.

Figure 28

Figure 29

MOUNTING

Moulded Case Circuit Breaker (MCCB)

Notes:All dimension are in mmThe details in this drawing indicate dimensions and knockout positions for one Load Center. Knockout details for other Load Center types, shown in this catalogue, are available on request

Page 14: APPLICATION - Alfanar · 2019-06-26 · gland plate for ease of cable entry fully shrouded busbars tin plated etp copper busbars without any joints polycarbonate for busbar support

12

MOULDED CASE CIRCUIT BREAKER

Frame size (AF)

Frame Type

Breaking capacity (kA), Icu at 415V AC

Number of poles

Type

Rated current (A) at 50 ºC

Technical data conforming to IEC/EN60947-2

Rated operational voltage (V) Ue (50/60 Hz)

Rated operational voltage (V) Ue (DC)

Rated insulation voltage (V) Ui (50/60Hz)

Rated impulse withstand voltage (kv)uimp

Ultimate breaking capacity (kA)Icu

AC 50/60 Hz

DC

Service breaking capacity(%Icu).Ics

Category of use

Endurance (number of operations)

Type of trip unit:

-Thermal-magnetic release

-Electronic release

-Pre-alarm via LED

-Hydraulic-magnetic release

Accessories

Dimensions (WxHxD) mm

Weight (kg) - MAX

220/240V

380/415V

440/460V

480/500V

600V

125V

250V

mechanical

electrical

100

ELA

14

3

ELA 100A

30,40

50,60,75,100

600

250

690

6

25

14

14

7.5

7.5

15

10

50

A

8500

1500

fixed

-

-

-

-

90x155x60

1.1

225

ELB

14

3

ELB 225A

125,150

175,200,225

600

250

690

6

25

14

14

7.5

7.5

15

10

50

A

7000

1000

fixed

-

-

-

-

105x165x68.5

1.3

3 pole

Moulded Case Circuit Breaker (MCCB)

,

TECHNICAL SPECIFICATION

Page 15: APPLICATION - Alfanar · 2019-06-26 · gland plate for ease of cable entry fully shrouded busbars tin plated etp copper busbars without any joints polycarbonate for busbar support

12

MOULDED CASE CIRCUIT BREAKER

Frame size (AF)

Frame Type

Breaking capacity (kA), Icu at 415V AC

Number of poles

Type

Rated current (A) at 50 ºC

Technical data conforming to IEC/EN60947-2

Rated operational voltage (V) Ue (50/60 Hz)

Rated operational voltage (V) Ue (DC)

Rated insulation voltage (V) Ui (50/60Hz)

Rated impulse withstand voltage (kv)uimp

Ultimate breaking capacity (kA)Icu

AC 50/60 Hz

DC

Service breaking capacity(%Icu).Ics

Category of use

Endurance (number of operations)

Type of trip unit:

-Thermal-magnetic release

-Electronic release

-Pre-alarm via LED

-Hydraulic-magnetic release

Accessories

Dimensions (WxHxD) mm

Weight (kg) - MAX

220/240V

380/415V

440/460V

480/500V

600V

125V

250V

mechanical

electrical

100

ELA

14

3

ELA 100A

30,40

50,60,75,100

600

250

690

6

25

14

14

7.5

7.5

15

10

50

A

8500

1500

fixed

-

-

-

-

90x155x60

1.1

225

ELB

14

3

ELB 225A

125,150

175,200,225

600

250

690

6

25

14

14

7.5

7.5

15

10

50

A

7000

1000

fixed

-

-

-

-

105x165x68.5

1.3

3 pole

Moulded Case Circuit Breaker (MCCB)

,

TECHNICAL SPECIFICATION

Page 16: APPLICATION - Alfanar · 2019-06-26 · gland plate for ease of cable entry fully shrouded busbars tin plated etp copper busbars without any joints polycarbonate for busbar support