aprilia rsv4 factory s u p p l e m e n t a r y m a n u a l · aprilia rsv4 factory 2009-2015 remove...

3
Aprilia RSV4 Factory 2009-2015 Remove the passanger and main seat. www.healtech-electronics.com S U P P L E M E N T A R Y M A N U A L for QSE-1 + QSH-P4F PAGE 1/3 Remove the frame covers below fuel tank. Raised up or remove the fuel tank.

Upload: others

Post on 25-Sep-2020

4 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Aprilia RSV4 Factory S U P P L E M E N T A R Y M A N U A L · Aprilia RSV4 Factory 2009-2015 Remove the passanger and main seat. S U P P L E M E N T A R Y M A N U A L for QSE-1 +

Aprilia RSV4 Factory2009-2015

Remove the passanger and main seat.

www.healtech-electronics.com

S U P P L E M E N T A R Y M A N U A Lfor QSE-1 + QSH-P4F

PAGE 1/3

Remove the frame covers below fuel tank.

Raised up or remove the fuel tank.

Page 2: Aprilia RSV4 Factory S U P P L E M E N T A R Y M A N U A L · Aprilia RSV4 Factory 2009-2015 Remove the passanger and main seat. S U P P L E M E N T A R Y M A N U A L for QSE-1 +

Aprilia RSV4 Factory2009-2015

www.healtech-electronics.com PAGE 2/3

Connect QSH connectors in-line with the ignition coil connectors on right side.

(front cylinder, black, 3-pole connectors)

Connect QSH connectors in-line with the ignition coil

connectors on .airbox(rear cylinder, black, 3-pole connectors)

Connect QSH connectors in-line with the ignition coil connectors on left side.

(front cylinder, black, 3-pole connectors)

Page 3: Aprilia RSV4 Factory S U P P L E M E N T A R Y M A N U A L · Aprilia RSV4 Factory 2009-2015 Remove the passanger and main seat. S U P P L E M E N T A R Y M A N U A L for QSE-1 +

Aprilia RSV4 Factory2009-2015

www.healtech-electronics.com PAGE 3/3

Typical position for theQuickShifter easy.

Mount the QSE sensor.(Use the new bolt and washers supplied with

the unit. Make sure to place one washer abovethe sensor and one washer below the sensor.

Use the spacer below the washer.Spacer size: 6mm*10mm*4mm

tighten the screw by 3-5 Nm.When tightened, do not try to rotate the

sensor body.)