aq-f201 overcurrent and earth-fault relay

3
AQ-F201 Overcurrent and earth-fault relay The AQ-F201 offers a compact solution for any application requiring non-directional overcurrent and earth-fault protection. Selection of supportive functions for protection, measurement, monitoring, control and communication along with large programmable HMI guarantee the best in class price performance ratio for basic range of relays. Highlights • Basic range • Price performance ratio Technical Data PROTECTION Three-phase overcurrent, 3 stages INST, DT or IDMT (50/51) Earth-fault (sensitive), 3 stages INST, DT or IDMT (50/51N) Harmonic overcurrent / inrush blocking, 1 stage INST, DT or IDMT (50/51H, 68) Current unbalance / broken conductor, 1 stage INST, DT or IDMT (46/46R/46L) High impedance restricted earth fault (87N) Breaker failure protection (50BF,52BF) CONTROL Controllable objects: 1 Cold-load pick-up block Switch onto fault logic 8 setting groups

Upload: others

Post on 16-Oct-2021

8 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: AQ-F201 Overcurrent and earth-fault relay

AQ-F201 Overcurrent and earth-fault relay

The AQ-F201 offers a compact solution for any applicationrequiring non-directional overcurrent and earth-faultprotection. Selection of supportive functions for protection,measurement, monitoring, control and communicationalong with large programmable HMI guarantee the best inclass price performance ratio for basic range of relays.

Highlights• Basic range• Price performance ratio

Technical Data

PROTECTION

Three-phase overcurrent, 3 stages INST, DT or IDMT (50/51)

Earth-fault (sensitive), 3 stages INST, DT or IDMT (50/51N)

Harmonic overcurrent / inrush blocking, 1 stage INST, DT or IDMT (50/51H, 68)

Current unbalance / broken conductor, 1 stage INST, DT or IDMT (46/46R/46L)

High impedance restricted earth fault (87N)

Breaker failure protection (50BF,52BF)

CONTROL

Controllable objects: 1

Cold-load pick-up block

Switch onto fault logic

8 setting groups

wlanz
Bild platziert
Walter
Textfeld
42technology AG (Ltd.) Bützbergstrasse 2c CH-4912 Aarwangen Tel: +41(0) 62-923 79 93 www.42technology.ch [email protected]
Page 2: AQ-F201 Overcurrent and earth-fault relay

AQ-F201 Overcurrent and earth-fault relay

MEASURING AND MONITORING

Phase and residual currents (IL1, IL2, IL3, I01, I02)

Current THD and harmonics (up to 31st)

Circuit breaker wear (CBW)

Disturbance recorder (3.2 kHz)

Current transformer supervision (CTS)

Trip circuit supervision (TCS)

Event recording

Non-volatile disturbance records: 100

Non-volatile event records: 15000

I/0

Current inputs: 5

Digital inputs: 3 (fixed)

Output relays: 5+1 (fixed)

COMMUNICATION

RJ 45 Ethernet 100Mb (front standard)

RJ 45 Ethernet 100Mb and RS 485 (rear standard)

Communication protocols

IEC 60870-5-103/101/104

Modbus RTU, Modbus TCP/IP

DNP 3.0, DNP 3.0 over TCP/IP

SPA

wlanz
Bild platziert
Walter
Textfeld
42technology AG (Ltd.) Bützbergstrasse 2c CH-4912 Aarwangen Tel: +41(0) 62-923 79 93 www.42technology.ch [email protected]
Page 3: AQ-F201 Overcurrent and earth-fault relay

AQ-F201 Overcurrent and earth-fault relay

Application Drawing

wlanz
Bild platziert
Walter
Textfeld
42technology AG (Ltd.) Bützbergstrasse 2c CH-4912 Aarwangen Tel: +41(0) 62-923 79 93 www.42technology.ch [email protected]