ara-fpsecio-mod - secure i/o module - bosch security and...

2
Systems | ARA-FPSECIO-MOD - Secure I/O module Secure I/O is a separate controller for door control and I/ O expansion. With encrypted communication to the finger print reader BioLite Solo, it provides secure and cost effective access control for the small to medium sized office. Functions For enhanced security the communication between the fingerprint reader and the secure IO is encrypted. Installation/Configuration Notes Installation example 1 = Power supply; 2 = Door lock; 3 = Exit button; 4 = Door sensor; 5 = RS485 secure communication; 6 = Secure I/O module ARA-FPSECIO-MOD - Secure I/O module Encrypted communication with the fingerprint reader Secure door control 4 digital inputs 2 relay outputs www.boschsecurity.com

Upload: others

Post on 31-Oct-2019

5 views

Category:

Documents


0 download

TRANSCRIPT

Systems | ARA-FPSECIO-MOD - Secure I/O module

Secure I/O is a separate controller for door control and I/O expansion. With encrypted communication to the fingerprint reader BioLite Solo, it provides secure and costeffective access control for the small to medium sizedoffice.

Functions

For enhanced security the communication between thefingerprint reader and the secure IO is encrypted.

Installation/Configuration Notes

Installation example

1 = Power supply; 2 = Door lock; 3 = Exit button;4 = Door sensor; 5 = RS485 secure communication;6 = Secure I/O module

ARA-FPSECIO-MOD - Secure I/O module▶ Encrypted communication with the fingerprint reader

▶ Secure door control

▶ 4 digital inputs

▶ 2 relay outputs

www.boschsecurity.com

2 | ARA-FPSECIO-MOD - Secure I/O module

Power connection

Recommended power supply

• 12V ±10%, at least 500mA for Secure IO aloneinstallation.

• Comply with standard IEC/EN 60950-1• To share the power with other devices, use a power

supply with higher current ratings.

RS485 connection

In case the length of RS-485 line is so long to affectcommunication stability, connect the enclosed 120 Ohmresistor between TRX+ and TRX-connector of Secure I/O.

Relay connection

Red line = fail secure lockGreen line = fail safe lockWhen using dead bolt or door strike, connect an encloseddiode as in the above diagram. Anode (line mark) of thediode should be connected to + power (Be careful of thedirection)

Technical Specifications

CPU 8 bit, 16 MHz Microcontroller

Memory 32 Kbyte flash

Display 10ea status LED

IO 4 digital inputs2 relay outputs

Size (W x H x D) 143 x 110 x 39 mm

Power voltage 12 V (max. 13.2 V)

Power current 500 mA (max. 800 mA)

Normal switching capacity (normal-ly open)

5 A – 125 Vac2 A – 250 Vac3 A – 30 Vdc

Normal switching capacity (normal-ly closed)

2 A – 125 Vac1 A – 250 Vac1 A – 30 Vdc

Ordering Information

ARA-FPSECIO-MOD - Secure I/O moduleAccessory unit for secure door control and I/O expansion.

ARA-FPSECIO-MOD

Americas:Bosch Security Systems, Inc.130 Perinton ParkwayFairport, New York, 14450, USAPhone: +1 800 289 0096Fax: +1 585 223 [email protected]

Europe, Middle East, Africa:Bosch Security Systems B.V.P.O. Box 800025600 JB Eindhoven, The NetherlandsPhone: + 31 40 2577 284Fax: +31 40 2577 [email protected]

Asia-Pacific:Robert Bosch (SEA) Pte Ltd, Security Systems11 Bishan Street 21Singapore 573943Phone: +65 6258 5511Fax: +65 6571 [email protected]

Represented by

© Bosch Security Systems Inc. 2010 | Data subject to change without noticeT6755897099 | Cur: en-US, V5, 28 Oct 2010