arc guard® power center - becker mining

2
performance | reliability | know-how PO Box 940 • Barboursville, WV 25504 • 304-733-7204 www.becker-global.com Becker Global-America’s patented Arc Guard® Power Center provides an added degree of protecon above the standard MSHA requirements. In addion to bolted faults, the Arc Guard™ is designed and performance tested to ANSI/IEEE C37.20.7 to provide protecon from the hazards of internal arcing faults. Protects from injury or death Minimizes damage to assets Maximizes producon Performance tested and classified as arc resistant ADDITIONAL FEATURES INCLUDE: • Unit Type Tested at KEMA Power Labs • Passed Stringent ANSI C37 Standards • Isolated Low Voltage Compartment • Isolated Transformer • Isolated Primary Disconnect Patent #8,648,274 STANDARD FEATURES INCLUDE: Class 2B Rang Arc resistant to protect workers at the front, back and sides of the equipment Performance tested and classified as arc resis- tant in accordance with ANSI/IEE C37.20.7-2007 Reinforced enclosure to withstand pressure from internal arcing faults Internal venng system with pressure dams and pressure vents to channel the flow of arc fault gases and vent these gases out of the top of the gear and away from personnel Reinforced and sealed top covers and panels Reinforced bolted covers Venlaon inlet/outlet shrouds Does not depend on electric Above & Beyond Arc Guard® Power Center goes the extra mile in safety.

Upload: others

Post on 15-Jan-2022

4 views

Category:

Documents


0 download

TRANSCRIPT

performance | reliability | know-how

PO Box 940 • Barboursville, WV 25504 • 304-733-7204www.becker-global.com

Becker Global-America’s patented Arc Guard® Power Center provides an added degree of protection above the standard MSHA requirements. In addition to bolted faults, the Arc Guard™ is designed and performance tested to ANSI/IEEE C37.20.7 to provide protection from the hazards of internal arcing faults.

►Protects from injury or death ►Minimizes damage to assets ►Maximizes production ►Performance tested and classified as arc resistant

ADDITIONAL FEATURES INCLUDE: • Unit Type Tested at KEMA Power Labs • Passed Stringent ANSI C37 Standards • Isolated Low Voltage Compartment • Isolated Transformer • Isolated Primary Disconnect

Patent #8,648,274

STANDARD FEATURES INCLUDE:

Class 2B Rating

Arc resistant to protect workers at the front, back and sides of the equipment

Performance tested and classified as arc resis-tant in accordance with ANSI/IEE C37.20.7-2007

Reinforced enclosure to withstand pressure from internal arcing faults

Internal venting system with pressure dams and pressure vents to channel the flow of arc fault gases and vent these gases out of the top of the gear and away from personnel

Reinforced and sealed top covers and panels

Reinforced bolted covers

Ventilation inlet/outlet shrouds

Does not depend on electric

Above & Beyond Arc Guard® Power Center goes the extra mile in safety.

performance | reliability | know-how

14660 Industrial Park Road • Bristol VA 24201 • 276-285-3841www.becker-global.com

Becker Global-America’s Arc Guard® Substations provide protection where it’s needed most. Protecting employees and equipment with above standard MSHA requirements and performance tested to ANSI/IEEE C37.20.7, these substations eliminate the hazards of internal arcing faults, which can be devastating.

ARC GUARD SUBSTATIONS FEATURES:

> Arc resistant to protect workers/equipment

> Detects faults in low- and medium-voltage switchgear and disconnects the power provided to the arc within 30 to 50 milliseconds

> The Arc Guard™ system can detect an arc flash in less than one millisecond

> Performance tested and classified as arc resistant in accordance with ANSI/IEE C37.20.7-2007

> Integrated assembly using reliable and cost-effective load interupter switches.

Protection for your people.Arc Guard® Substations eliminate arc hazards.

Patent #8,648,274