Architecture and Design for VMwareNSX-T for Workload Domains withMultiple Availability Zones

03 SEP 2019VMware Validated Design 5.1VMware NSX-T 2.4.1

Page 2: Architecture and Design for VMware NSX-T for …...Architecture and Design for VMware NSX-T for Workload Domains with Multiple Availability Zones 03 SEP 2019 VMware Validated Design

You can find the most up-to-date technical documentation on the VMware website at:

https://docs.vmware.com/

If you have comments about this documentation, submit your feedback to

[email protected]

VMware, Inc.3401 Hillview Ave.Palo Alto, CA 94304www.vmware.com

Copyright © 2018-2019 VMware, Inc. All rights reserved. Copyright and trademark information.

Architecture and Design for VMware NSX-T for Workload Domains with Multiple Availability Zones

VMware, Inc. 2

Page 3: Architecture and Design for VMware NSX-T for …...Architecture and Design for VMware NSX-T for Workload Domains with Multiple Availability Zones 03 SEP 2019 VMware Validated Design

Contents

About Architecture and Design for VMware NSX-T for Workload Domains with MultipleAvailability Zones 4

1 Applying the Guidance for VMware NSX-T Workload Domains with Multiple AvailabilityZones 5

2 Architecture Overview 7Physical Network Architecture for NSX-T Workload Domains with Multiple Availability Zones 7

Network Transport for NSX-T Workload Domains with Multiple Availability Zones 7

Virtual Infrastructure Architecture for NSX-T Workload Domains with Multiple Availability Zones 9

Virtual Infrastructure Overview for NSX-T Workload Domains with Multiple Availability Zones 10

Network Virtualization Components for NSX-T Workload Domains with Multiple Availability Zones12

Network Virtualization Services for NSX-T Workload Domains with Multiple Availability Zones 13

3 Detailed Design 16Physical Infrastructure Design for NSX-T Workload Domains with Multiple Availability Zones 16

Physical Networking Design for NSX-T Workload Domains with Multiple Availability Zones 17

Virtual Infrastructure Design for NSX-T Workload Domains with Multiple Availability Zones 22

vSphere Cluster Design for NSX-T Workload Domains with Multiple Availability Zones 23

vSAN Storage Design for NSX-T Workload Domains with Multiple Availability Zones 28

Virtualization Network Design for NSX-T Workload Domains with Multiple Availability Zones 38

NSX Design for NSX-T Workload Domains with Multiple Availability Zones 47

VMware, Inc. 3

Page 4: Architecture and Design for VMware NSX-T for …...Architecture and Design for VMware NSX-T for Workload Domains with Multiple Availability Zones 03 SEP 2019 VMware Validated Design

About Architecture and Design forVMware NSX-T for Workload Domainswith Multiple Availability Zones

Architecture and Design for VMware NSX-T for Workload Domains with Multiple Availability Zonesprovides detailed information about the requirements for software, tools, and external services toimplement VMware NSX-T™ Data Center in a shared edge and compute cluster in an SDDC that iscompliant with VMware Validated Design™ for Software-Defined Data Center.

PrerequisitesDeploy the management cluster according to VMware Validated Design for Software-Defined Data Centerat least in a single region. See the VMware Validated Design documentation page.

Intended AudienceThis design is intended for architects and administrators who want to deploy NSX-T in a virtualinfrastructure workload domain with VMware vSAN stretched clusters for tenant workloads.

Required VMware SoftwareIn addition to the VMware Validated Design for Software-Defined Data Center 5.1 deployment, you mustdownload NSX-T 2.4.1. You then deploy and configure NSX-T in the shared edge and compute clusteraccording to this guide. See VMware Validated Design Release Notes for more information aboutsupported product versions

VMware, Inc. 4

Page 5: Architecture and Design for VMware NSX-T for …...Architecture and Design for VMware NSX-T for Workload Domains with Multiple Availability Zones 03 SEP 2019 VMware Validated Design

Applying the Guidance forVMware NSX-T WorkloadDomains with MultipleAvailability Zones 1The content in Architecture and Design for VMware NSX-T for Workload Domains with MultipleAvailability Zones replaces certain parts of Architecture and Design in VMware Validated Design forSoftware-Defined Data Center, also referred to as the Standard SDDC.

Before You Design the Virtual Infrastructure WorkloadDomain with NSX-TBefore you follow this documentation, you must deploy the components for the SDDC managementcluster according to VMware Validated Design for Software-Defined Data Center at least in a singleregion. See Architecture and Design, Planning and Preparation and Deployment for Region A in theVMware Validated Design documentation.

n VMware ESXi™

n VMware Platform Services Controller™ pair and Management vCenter Server®

n VMware NSX® Data Center for vSphere®

n VMware vRealize® Lifecycle Manager™

n vSphere® Update Manager™

n VMware vRealize® Operations Manager™

n VMware vRealize® Log Insight™

n VMware vRealize® Automation™ with embedded vRealize® Orchestrator™

n VMware vRealize® Business™ for Cloud

VMware, Inc. 5

Page 6: Architecture and Design for VMware NSX-T for …...Architecture and Design for VMware NSX-T for Workload Domains with Multiple Availability Zones 03 SEP 2019 VMware Validated Design

Designing a Virtual Infrastructure Workload Domain withNSX-TNext, follow the guidance to design a virtual infrastructure (VI) workload domain with NSX-T deployed inthis way:

n In general, use the guidelines about the VI workload domain and shared edge and compute cluster inthe following sections of Architecture and Design in VMware Validated Design for Software-DefinedData Center:

n Architecture Overview > Physical Infrastructure Architecture

n Architecture Overview > Virtual Infrastructure Architecture

n Detailed Design > Physical Infrastructure Design

n Detailed Design > Virtual Infrastructure Design

n For the sections that are available in both Architecture and Design for VMware NSX-T for WorkloadDomains with Multiple Availability Zones and Architecture and Design, follow the design guidelines inArchitecture and Design for VMware NSX-T for Workload Domains with Multiple Availability Zones.

First-Level Chapter Places to Use the Guidance for NSX-T

Architecture Overview n Physical Infrastructure Architecture

• Workload Domain Architecture

• Cluster Types

• Physical Network Architecture

• Network Transport• Infrastructure Network Architecture

• Physical Network Interfaces

n Virtual Infrastructure Architecture

Detailed Design n Physical Infrastructure Design

• Physical Design Fundamentals

• Physical Networking Design• Physical Storage Design

n Virtual Infrastructure Design

• vCenter Server Design

• vCenter Server Deployment

• vCenter Server Networking

• vCenter Server Redundancy

• vCenter Server Appliance Sizing

• vSphere Cluster Design• vCenter Server Customization

• Use of TLS Certificates in vCenter Server

• Virtualization Network Design• NSX-T Design

Architecture and Design for VMware NSX-T for Workload Domains with Multiple Availability Zones

VMware, Inc. 6

Page 7: Architecture and Design for VMware NSX-T for …...Architecture and Design for VMware NSX-T for Workload Domains with Multiple Availability Zones 03 SEP 2019 VMware Validated Design

Architecture Overview 2VMware Validated Design for NSX-T enables IT organizations that have deployed VMware ValidatedDesign for Software-Defined Data Center 5.1 to create a shared edge and compute cluster that usesNSX-T capabilities.

This chapter includes the following topics:

n Physical Network Architecture for NSX-T Workload Domains with Multiple Availability Zones

n Virtual Infrastructure Architecture for NSX-T Workload Domains with Multiple Availability Zones

Physical Network Architecture for NSX-T WorkloadDomains with Multiple Availability ZonesVMware Validated Designs can use most physical network architectures.

Network Transport for NSX-T Workload Domains with MultipleAvailability ZonesYou can implement the physical layer switch fabric of an SDDC by offering Layer 2 or Layer 3 transportservices. For a scalable and vendor-neutral data center network, use a Layer 3 transport.

VMware Validated Design supports both Layer 2 and Layer 3 transports. To decide whether to use Layer2 or Layer 3, consider the following factors:

n NSX-T service routers establish Layer 3 routing adjacency with the first upstream Layer 3 device toprovide equal cost routing for workloads.

n The investment you have today in your current physical network infrastructure.

n The benefits and drawbacks for both layer 2 and layer 3 designs.

Benefits and Drawbacks of Layer 2 TransportA design using Layer 2 transport has these considerations:

n In a design that uses Layer 2 transport, top of rack switches and upstream Layer 3 devices, such ascore switches or routers, form a switched fabric.

n The upstream Layer 3 device terminates each VLAN and provides default gateway functionality.

n Uplinks from the top of rack switch to the upstream Layer 3 devices are 802.1Q trunks carrying allrequired VLANs.

Using a Layer 2 transport has the following benefits and drawbacks:

VMware, Inc. 7

Page 8: Architecture and Design for VMware NSX-T for …...Architecture and Design for VMware NSX-T for Workload Domains with Multiple Availability Zones 03 SEP 2019 VMware Validated Design

Table 2-1. Benefits and Drawbacks for Layer 2 Transport

Characteristic Description

Benefits n More design freedom.

n You can span VLANs across racks.

Drawbacks n The size of such a deployment is limited because the fabricelements have to share a limited number of VLANs.

n You might have to rely on a specialized data centerswitching fabric product from a single vendor.

n Traffic between VLANs must traverse to upstream Layer 3device to be routed.

Figure 2-1. Example Layer 2 Transport

ToR ToR

ESXiHost

Upstream L3 DeviceL3

25 GbE 25 GbE

L2

Upstream L3 Device

Benefits and Drawbacks of Layer 3 TransportA design using Layer 3 transport requires these considerations:

n Layer 2 connectivity is limited within the data center rack up to the top of rack switches.

n The top of rack switch terminates each VLAN and provides default gateway functionality. The top ofrack switch has a switch virtual interface (SVI) for each VLAN.

n Uplinks from the top of rack switch to the upstream layer are routed point-to-point links. You cannotuse VLAN trunking on the uplinks.

n A dynamic routing protocol, such as BGP, connects the top of rack switches and upstream switches.Each top of rack switch in the rack advertises a small set of prefixes, typically one per VLAN orsubnet. In turn, the top of rack switch calculates equal cost paths to the prefixes it receives from othertop of rack switches.

Architecture and Design for VMware NSX-T for Workload Domains with Multiple Availability Zones

VMware, Inc. 8

Page 9: Architecture and Design for VMware NSX-T for …...Architecture and Design for VMware NSX-T for Workload Domains with Multiple Availability Zones 03 SEP 2019 VMware Validated Design

Table 2-2. Benefits and Drawbacks of Layer 3 Transport

Characteristic Description

Benefits n You can select from many Layer 3 capable switch productsfor the physical switching fabric.

n You can mix switches from different vendors because ofgeneral interoperability between their implementation ofBGP.

n This approach is typically more cost effective because ituses only the basic functionality of the physical switches.

Drawbacks n VLANs are restricted to a single rack. The restriction canaffect vSphere Fault Tolerance, and storage networks.

Figure 2-2. Example Layer 3 Transport

ToR

L3

ESXiHost

UpstreamSwitch

UpstreamSwitch

WAN/MPLSInternet

WAN/MPLSInternet

ToR

L2

25 GbE25 GbE

Virtual Infrastructure Architecture for NSX-T WorkloadDomains with Multiple Availability ZonesThe virtual infrastructure is the foundation of an operational SDDC. It contains the software-definedinfrastructure, software-defined networking and software-defined storage.

In the virtual infrastructure layer, access to the underlying physical infrastructure is controlled andallocated to the management and compute workloads. The virtual infrastructure layer consists of thehypervisors on the physical hosts and the control of these hypervisors. The management components ofthe SDDC consist of elements in the virtual management layer itself.

Architecture and Design for VMware NSX-T for Workload Domains with Multiple Availability Zones

VMware, Inc. 9

Page 10: Architecture and Design for VMware NSX-T for …...Architecture and Design for VMware NSX-T for Workload Domains with Multiple Availability Zones 03 SEP 2019 VMware Validated Design

Figure 2-3. Virtual Infrastructure Layer in the SDDC

ServiceManagement

Portfolio Management

OperationsManagement

CloudManagement

Layer

Service Catalog

Self-Service Portal

Orchestration

BusinessContinuity

Fault Tolerance and Disaster

Recovery

Backup & Restore

Hypervisor

Pools of Resources

Virtualization Control

VirtualInfrastructure

Layer

Compute

Storage

Network

PhysicalLayer

Replication

Security and Compliance

Mapping to Regulations

Enhanced Guidance

Built-In Controls

Virtual Infrastructure Overview for NSX-T Workload Domains withMultiple Availability ZonesThe SDDC virtual infrastructure consists of workload domains. The SDDC virtual infrastructure includes amanagement workload domain that contains the management cluster and a virtual infrastructure workloaddomain that contains the shared edge and compute cluster.

Management ClusterThe management cluster runs the virtual machines that manage the SDDC. These virtual machines hostvCenter Server, vSphere Update Manager, NSX Manager, and other management components. Allmanagement, monitoring, and infrastructure services are provisioned to a vSphere cluster which provideshigh availability for these critical services. Permissions on the management cluster limit access only toadministrators. This limitation protects the virtual machines that are running the management, monitoring,and infrastructure services from unauthorized access. The management cluster leverages software-defined networking capabilities in NSX for vSphere.

The management cluster architecture and design is covered in the VMware Validated Design forSoftware-Defined Data Center. The NSX-T validated design does not include the design of themanagement cluster.

Shared Edge and Compute ClusterThe shared edge and compute cluster runs the NSX-T edge virtual machines and all tenant workloads.The edge virtual machines are responsible for North-South routing between compute workloads and theexternal network. This is often referred to as the on-off ramp of the SDDC. The NSX-T edge virtualmachines also enable services such as load balancers.

The hosts in this cluster provide services such as high availability to the NSX-T edge virtual machinesand tenant workloads.

Architecture and Design for VMware NSX-T for Workload Domains with Multiple Availability Zones

VMware, Inc. 10

Page 11: Architecture and Design for VMware NSX-T for …...Architecture and Design for VMware NSX-T for Workload Domains with Multiple Availability Zones 03 SEP 2019 VMware Validated Design

Figure 2-4. SDDC Logical Design

APP

OSAPP

OS

APP

OS

APP

OS

APP

OS

APP

OS

APP

OS

APP

OSAPP

OSAPP

OS

APP

OSAPP

OS

APP

OSAPP

OS

APP

OSAPP

OS

APP

OS

APP

OSAPP

OS

APP

OSAPP

OSAPP

OS

APP

OSAPP

OS

Virtual InfrastructureManagement

NSXControllers

(Mgmt)

OtherManagementApplications

NSXManager(Mgmt)

NSX-TManager Cluster

(Compute)

NSX-T Edges(Compute)

ESXi

TransportNodes

ESXi ESXi ESXi

SDDCPayload

Virtual Infrastructure Compute Edge

NSX-T Transport Zones (Compute)

N-VDS (Compute) vDS (Mgmt)

NSX-V Transport Zones (Mgmt)

Stretched Shared Edge and Compute Cluster

Stretched Management Cluster

Managed by: Compute vCenter Server

Managed by:Management vCenter Server

Network: External(Internet/Corporate)Network: Internal SDDC

vCenterServer(Mgmt)

vCenterServer

(Compute)

ESXiESXi

TransportNodes

ESXi

TransportNodes

ESXi

TransportNodes

Availability Zone 1 - Management and Shared Edge and Compute Clusters

ESXi

TransportNodes

ESXi ESXi ESXiESXi

ESXi

TransportNodes

ESXi

TransportNodes

ESXi

TransportNodes

N-VDS (Compute) vDS (Mgmt)

NSX-T Transport Zones (Compute) NSX-V Transport Zones (Mgmt)

Availability Zone 2 (Secondary) - Management and Shared Edge and Compute Clusters

Virtual InfrastructureManagement

NSX-TSecondary Edge(Mgmt)

OtherManagementApplications

NSX-T Edges(Compute)

SDDCPayload

Virtual Infrastructure Compute Edge

Architecture and Design for VMware NSX-T for Workload Domains with Multiple Availability Zones

VMware, Inc. 11

Page 12: Architecture and Design for VMware NSX-T for …...Architecture and Design for VMware NSX-T for Workload Domains with Multiple Availability Zones 03 SEP 2019 VMware Validated Design

Network Virtualization Components for NSX-T Workload Domainswith Multiple Availability ZonesThe NSX-T platform consists of several components that are relevant to the network virtualization design.

NSX-T PlatformNSX-T creates a network virtualization layer, which is an abstraction between the physical and virtualnetworks. You create all virtual networks on top of this layer.

Several components are required to create this network virtualization layer:

n NSX-T Managers

n NSX-T Edge Nodes

n NSX-T Distributed Routers (DR)

n NSX-T Service Routers (SR)

n NSX-T Segments (Logical Switches)

These components are distributed in different planes to create communication boundaries and provideisolation of workload data from system control messages.

Data plane Performs stateless forwarding or transformation of packets based on tablespopulated by the control plane, reports topology information to the controlplane, and maintains packet level statistics.

The following traffic runs in the data plane:

n Workload data

n N-VDS virtual switch, distributed routing, and the distributed firewall inNSX-T

The data is carried over designated transport networks in the physicalnetwork.

Control plane Contains messages for network virtualization control. You place the controlplane communication on secure physical networks (VLANs) that areisolated from the transport networks for the data plane.

The control plane computes the runtime state based on configuration fromthe management plane. Control plane propagates topology informationreported by the data plane elements, and pushes stateless configuration toforwarding engines.

Control plane in NSX-T has two parts:

n Central Control Plane (CCP). The CCP is implemented as a cluster ofvirtual machines called CCP nodes. The cluster form factor providesboth redundancy and scalability of resources.

Architecture and Design for VMware NSX-T for Workload Domains with Multiple Availability Zones

VMware, Inc. 12

Page 13: Architecture and Design for VMware NSX-T for …...Architecture and Design for VMware NSX-T for Workload Domains with Multiple Availability Zones 03 SEP 2019 VMware Validated Design

The CCP is logically separated from all data plane traffic, that is, afailure in the control plane does not affect existing data planeoperations.

n Local Control Plane (LCP). The LCP runs on transport nodes. It is nearto the data plane it controls and is connected to the CCP. The LCP isresponsible for programming the forwarding entries of the data plane.

Management plane Provides a single API entry point to the system, persists user configuration,handles user queries, and performs operational tasks on all management,control, and data plane nodes in the system.

For NSX-T, all querying, modifying, and persisting user configuration is inthe management plane. Propagation of that configuration down to thecorrect subset of data plane elements is in the control plane. As a result,some data belongs to multiple planes. Each plane uses this data accordingto stage of existence. The management plane also queries recent statusand statistics from the control plane, and under certain conditions directlyfrom the data plane.

The management plane is the only source of truth for the logical systembecause it is the only entry point for user configuration. You make changesusing either a RESTful API or the NSX-T user interface.

For example, responding to a vSphere vMotion operation of a virtualmachine is responsibility of the control plane, but connecting the virtualmachine to the logical network is responsibility of the management plane.

Network Virtualization Services for NSX-T Workload Domains withMultiple Availability ZonesNetwork virtualization services include segments, gateways, firewalls, and other components of NSX-T.

Segments (LogicalSwitch)

Reproduces switching functionality, broadcast, unknown unicast, andmulticast (BUM) traffic in a virtual environment that is decoupled from theunderlying hardware.

Segments are similar to VLANs because they provide network connectionsto which you can attach virtual machines. The virtual machines can thencommunicate with each other over tunnels between ESXi hosts. EachSegment has a virtual network identifier (VNI), like a VLAN ID. UnlikeVLANs, VNIs scale beyond the limits of VLAN IDs.

Gateway (LogicalRouter)

Provides North-South connectivity so that workloads can access externalnetworks, and East-West connectivity between logical networks.

Architecture and Design for VMware NSX-T for Workload Domains with Multiple Availability Zones

VMware, Inc. 13

Page 14: Architecture and Design for VMware NSX-T for …...Architecture and Design for VMware NSX-T for Workload Domains with Multiple Availability Zones 03 SEP 2019 VMware Validated Design

A Logical Router is a configured partition of a traditional network hardwarerouter. It replicates the functionality of the hardware, creating multiplerouting domains in a single router. Logical Routers perform a subset of thetasks that are handled by the physical router, and each can contain multiplerouting instances and routing tables. Using logical routers can be aneffective way to maximize router use, because a set of logical routers withina single physical router can perform the operations previously performed byseveral pieces of equipment.

n Distributed router (DR)

A DR spans ESXi hosts whose virtual machines are connected to thisgateway, and edge nodes the gateway is bound to. Functionally, theDR is responsible for one-hop distributed routing between segmentsand gateways connected to this gateway.

n One or more (optional) service routers (SR).

An SR is responsible for delivering services that are not currentlyimplemented in a distributed fashion, such as stateful NAT.

A gateway always has a DR. A gateway has SRs when it is a Tier-0gateway, or when it is a Tier-1 gateway and has services configured suchas NAT or DHCP.

NSX-T Edge Node Provides routing services and connectivity to networks that are external tothe NSX-T domain through a Tier-0 gateway over BGP or static routing.

You must deploy an NSX-T Edge for stateful services at either the Tier-0 orTier-1 gateways.

NSX-T Edge Cluster Represents a collection of NSX-T Edge nodes that host multiple servicerouters in highly available configurations. At a minimum, deploy a singleTier-0 SR to provide external connectivity.

An NSX-T Edge cluster does not have a one-to-one relationship with avSphere cluster. A vSphere cluster can run multiple NSX-T Edge clusters.

Transport Node Participates in NSX-T overlay or NSX-T VLAN networking. If a nodecontains an NSX-T Virtual Distributed Switch (N-VDS) such as ESXi hostsand NSX-T Edge nodes, it can be a transport node.

If an ESXi host contains at least one N-VDS, it can be a transport node.

Transport Zone A transport zone can span one or more vSphere clusters. Transport zonesdictate which ESXi hosts and which virtual machines can participate in theuse of a particular network.

Architecture and Design for VMware NSX-T for Workload Domains with Multiple Availability Zones

VMware, Inc. 14

Page 15: Architecture and Design for VMware NSX-T for …...Architecture and Design for VMware NSX-T for Workload Domains with Multiple Availability Zones 03 SEP 2019 VMware Validated Design

A transport zone defines a collection of ESXi hosts that can communicatewith each other across a physical network infrastructure. Thiscommunication happens over one or more interfaces defined as TunnelEndpoints (TEPs).

When you create an ESXi host transport node and then add the node to atransport zone, NSX-T installs an N-VDS on the host. For each transportzone that the host belongs to, a separate N-VDS is installed. The N-VDS isused for attaching virtual machines to NSX-T Segments and for creatingNSX-T gateway uplinks and downlinks.

NSX-T Controller As a component of the control plane, the controllers control virtual networksand overlay transport tunnels.

For stability and reliability of data transport, NSX-T deploys the NSX-TController as a role in the Manager cluster which consists of three highlyavailable virtual appliances. They are responsible for the programmaticdeployment of virtual networks across the entire NSX-T architecture.

Logical Firewall Responsible for traffic handling in and out the network according to firewallrules.

A logical firewall offers multiple sets of configurable Layer 3 and Layer 2rules. Layer 2 firewall rules are processed before Layer 3 rules. You canconfigure an exclusion list to exclude segments, logical ports, or groupsfrom firewall enforcement.

The default rule, located at the bottom of the rule table, is a catch-all rule.The logical firewall enforces the default rule on packets that do not matchother rules. After the host preparation operation, the default rule is set tothe allow action. Change this default rule to a block action and enforceaccess control through a positive control model, that is, only traffic definedin a firewall rule can flow on the network.

Logical Load Balancer Provides high-availability service for applications and distributes thenetwork traffic load among multiple servers.

The load balancer accepts TCP, UDP, HTTP, or HTTPS requests on thevirtual IP address and determines which pool server to use.

Logical load balancer is supported only in an SR on the Tier-1 gateway.

Architecture and Design for VMware NSX-T for Workload Domains with Multiple Availability Zones

VMware, Inc. 15

Page 16: Architecture and Design for VMware NSX-T for …...Architecture and Design for VMware NSX-T for Workload Domains with Multiple Availability Zones 03 SEP 2019 VMware Validated Design

Detailed Design 3The NSX-T detailed design considers both physical and virtual infrastructure design. It includes numbereddesign decisions and the justification and implications of each decision.

This chapter includes the following topics:

n Physical Infrastructure Design for NSX-T Workload Domains with Multiple Availability Zones

n Virtual Infrastructure Design for NSX-T Workload Domains with Multiple Availability Zones

Physical Infrastructure Design for NSX-T WorkloadDomains with Multiple Availability ZonesThe physical infrastructure design includes design decision details for the physical network.

Figure 3-1. Physical Infrastructure Design

ServiceManagement

Portfolio Management

OperationsManagement

CloudManagement

Layer

Service Catalog

Self-Service Portal

Orchestration

BusinessContinuity

Fault Tolerance and Disaster

Recovery

Backup & Restore

Hypervisor

Pools of Resources

Virtualization Control

VirtualInfrastructure

Layer

Compute

Storage

Network

PhysicalLayer

Replication

Security and Compliance

Mapping to Regulations

Enhanced Guidance

Built-In Controls

n Physical Networking Design for NSX-T Workload Domains with Multiple Availability Zones

Design of the physical SDDC network includes defining the network topology for connecting thephysical switches and the ESXi hosts, determining switch port settings for VLANs and linkaggregation, and designing routing. You can use the VMware Validated Design guidance for designand deployment with most enterprise-grade physical network architectures.

VMware, Inc. 16

Page 17: Architecture and Design for VMware NSX-T for …...Architecture and Design for VMware NSX-T for Workload Domains with Multiple Availability Zones 03 SEP 2019 VMware Validated Design

Physical Networking Design for NSX-T Workload Domains withMultiple Availability ZonesDesign of the physical SDDC network includes defining the network topology for connecting the physicalswitches and the ESXi hosts, determining switch port settings for VLANs and link aggregation, anddesigning routing. You can use the VMware Validated Design guidance for design and deployment withmost enterprise-grade physical network architectures.

n Switch Types and Network Connectivity for NSX-T Workload Domains with Multiple AvailabilityZones

Follow the best practices for physical switches, switch connectivity, VLANs and subnets, and accessport settings.

n Physical Network Design Decisions for NSX-T Workload Domains with Multiple Availability Zones

The physical network design decisions determine the physical layout and use of VLANs. They alsoinclude decisions on jumbo frames and on other network-related requirements such as DNS andNTP.

Switch Types and Network Connectivity for NSX-T Workload Domains withMultiple Availability ZonesFollow the best practices for physical switches, switch connectivity, VLANs and subnets, and access portsettings.

Top of Rack Physical Switches

When configuring top of rack (ToR) switches, consider the following best practices:

n Configure redundant physical switches to enhance availability.

n Configure switch ports that connect to ESXi hosts manually as trunk ports.

n Modify the Spanning Tree Protocol (STP) on any port that is connected to an ESXi NIC to reduce thetime to transition ports over to the forwarding state, for example using the Trunk PortFast featurefound in a Cisco physical switch.

n Provide DHCP or DHCP Helper capabilities on all VLANs used by TEP VMkernel ports. This setupsimplifies the configuration by using DHCP to assign IP address based on the IP subnet in use.

n Configure jumbo frames on all switch ports, inter-switch link (ISL), and switched virtual interfaces(SVIs).

Top of Rack Connectivity and Network Settings

Each ESXi host is connected redundantly to the ToR switches SDDC network fabric by two 25 GbE ports.Configure the ToR switches to provide all necessary VLANs using an 802.1Q trunk. These redundantconnections use features in vSphere Distributed Switch and NSX-T to guarantee that no physicalinterface is overrun and available redundant paths are used.

Architecture and Design for VMware NSX-T for Workload Domains with Multiple Availability Zones

VMware, Inc. 17

Page 18: Architecture and Design for VMware NSX-T for …...Architecture and Design for VMware NSX-T for Workload Domains with Multiple Availability Zones 03 SEP 2019 VMware Validated Design

Figure 3-2. Host to ToR Connectivity

ToR ToR

ESXiHost

25 GbE 25 GbE

VLANs and Subnets

Each ESXi host uses VLANs and corresponding subnets.

Follow these guidelines:

n Use only /24 subnets to reduce confusion and mistakes when handling IPv4 subnetting.

n Use the IP address .254 as the (floating) interface with .252 and .253 for Virtual Router RedundancyProtocol (VRPP) or Hot Standby Routing Protocol (HSRP).

n Use the RFC1918 IPv4 address space for these subnets and allocate one octet by region andanother octet by function.

Note The following VLANs and IP ranges are samples. Your actual implementation depends on yourenvironment.

Table 3-1. Sample Values for VLANs and IP Ranges

Availability Zone Function Sample VLAN Sample IP Range

Availability Zone 1

Availability Zone 2

Management 1641

(Stretched)

172.16.41.0/24

Availability Zone 1 vSphere vMotion 1642 172.16.42.0/24

Availability Zone 1 vSAN 1643 172.16.43.0/24

Availability Zone 1 Host Overlay 1644 172.16.44.0/24

Availability Zone 1 Uplink01 1647 172.16.47.0/24

Availability Zone 1 Uplink02 1648 172.16.48.0/24

Availability Zone 1 Edge Overlay 1649 172.16.49.0/24

Availability Zone 2

Availability Zone 1

Management 1651

(Stretched)

172.16.51.0/24

Availability Zone 2 vSphere vMotion 1652 172.16.52.0/24

Availability Zone 2 vSAN 1653 172.16.53.0/24

Availability Zone 2 Host Overlay 1654 172.16.54.0/24

Availability Zone 2 Uplink01 1657 172.16.57.0/24

Architecture and Design for VMware NSX-T for Workload Domains with Multiple Availability Zones

VMware, Inc. 18

Page 19: Architecture and Design for VMware NSX-T for …...Architecture and Design for VMware NSX-T for Workload Domains with Multiple Availability Zones 03 SEP 2019 VMware Validated Design

Table 3-1. Sample Values for VLANs and IP Ranges (continued)

Availability Zone Function Sample VLAN Sample IP Range

Availability Zone 2 Uplink02 1658 172.16.58.0/24

Availability Zone 2 Edge Overlay 1659 172.16.59.0/24

Note The management network in each Availability Zone is stretched so that NSX-T Edge devices canfail over between availability zones.

Access Port Network Settings

Configure additional network settings on the access ports that connect the ToR switches to thecorresponding servers.

Spanning Tree Protocol(STP)

Although this design does not use the Spanning Tree Protocol, switchesusually include STP configured by default. Designate the access ports astrunk PortFast.

Trunking Configure the VLANs as members of a 802.1Q trunk with the managementVLAN acting as the native VLAN.

MTU Set MTU for all VLANs and SVIs (Management, vMotion, VXLAN, andStorage) to jumbo frames for consistency purposes.

DHCP Helper Configure a DHCP helper (sometimes called a DHCP relay) on all TEPVLANs.

Physical Network Design Decisions for NSX-T Workload Domains withMultiple Availability ZonesThe physical network design decisions determine the physical layout and use of VLANs. They alsoinclude decisions on jumbo frames and on other network-related requirements such as DNS and NTP.

Physical Network Design Decisions

Routing protocols NSX-T supports only the BGP routing protocol.

DHCP Helper Set the DHCP helper (relay) to point to a DHCP server by IPv4 address.

Architecture and Design for VMware NSX-T for Workload Domains with Multiple Availability Zones

VMware, Inc. 19

Page 20: Architecture and Design for VMware NSX-T for …...Architecture and Design for VMware NSX-T for Workload Domains with Multiple Availability Zones 03 SEP 2019 VMware Validated Design

Table 3-2. Physical Network Design Decisions

Decision ID Design Decision Design Justification Design Implication

NSXT-PHY-NET-001 Implement the followingphysical network architecture:

n One 25 GbE (10 GbEminimum) port on eachToR switch for ESXi hostuplinks.

n No EtherChannel (LAG/LACP/vPC) configurationfor ESXi host uplinks

n Layer 3 device thatsupports BGP.

n Guarantees availabilityduring a switch failure.

n Uses BGP as the onlydynamic routing protocolthat is supported by NSX-T.

n Might limit the hardwarechoice.

n Requires dynamic routingprotocol configuration inthe physical network.

NSXT-PHY-NET-002 Use a physical network that isconfigured for BGP routingadjacency.

n Supports flexibility innetwork design for routingmulti-site and multi-tenancy workloads.

n Uses BGP as the onlydynamic routing protocolthat is supported by NSX-T.

Requires BGP configuration inthe physical network.

NSXT-PHY-NET-003 Use two ToR switches foreach rack.

Supports the use of two 10GbE (25 GbE recommended)links to each server andprovides redundancy andreduces the overall designcomplexity.

Requires two ToR switches perrack which can increase costs.

NSXT-PHY-NET-004 Use VLANs to segmentphysical network functions.

n Supports physicalnetwork connectivitywithout requiring manyNICs.

n Isolates the differentnetwork functions of theSDDC so that you canhave differentiatedservices and prioritizedtraffic as needed.

Requires uniform configurationand presentation on all thetrunks made available to theESXi hosts.

Additional Design Decisions

Additional design decisions deal with static IP addresses, DNS records, and the required NTP timesource.

Architecture and Design for VMware NSX-T for Workload Domains with Multiple Availability Zones

VMware, Inc. 20

Page 21: Architecture and Design for VMware NSX-T for …...Architecture and Design for VMware NSX-T for Workload Domains with Multiple Availability Zones 03 SEP 2019 VMware Validated Design

Table 3-3. IP Assignment, DNS, and NTP Design Decisions

Decision ID Design Decision Design Justification Design Implication

NSXT-PHY-NET-005 Assign static IP addresses toall management componentsin the SDDC infrastructureexcept for NSX-T TEPs.

NSX-T TEPs are assigned byusing a DHCP server. Set thelease duration for the TEPDHCP scope to at least 7days.

Ensures that interfaces suchas management and storagealways have the same IPaddress. In this way, youprovide support forcontinuous management ofESXi hosts using vCenterServer and for provisioning IPstorage by storageadministrators.

NSX-T TEPs do not have anadministrative endpoint. As aresult, they can use DHCP forautomatic IP addressassignment. IP pools are anoption but the NSX-Tadministrator must createthem. If you must change orexpand the subnet, changingthe DHCP scope is simplerthan creating an IP pool andassigning it to the ESXi hosts.

Requires accurate IP addressmanagement.

NSXT-PHY-NET-006 Create DNS records for allESXi Hosts managementinterfaces to enable forward(A), reverse (PTR), short, andFQDN resolution.

Ensures consistent resolutionof management nodes usingboth IP address (reverselookup) and name resolution.

None.

NSXT-PHY-NET-007 Use an NTP time source forall management nodes.

Maintains accurate andsynchronized time betweenmanagement nodes.

None.

Jumbo Frames Design Decisions

IP storage throughput can benefit from the configuration of jumbo frames. Increasing the per-framepayload from 1500 bytes to the jumbo frame setting improves the efficiency of data transfer. You mustconfigure jumbo frames end-to-end. Select an MTU that matches the MTU of the physical switch ports.

According to the purpose of the workload, determine whether to configure jumbo frames on a virtualmachine. If the workload consistently transfers large amounts of network data, configure jumbo frames, ifpossible. In that case, confirm that both the virtual machine operating system and the virtual machineNICs support jumbo frames.

Using jumbo frames also improves the performance of vSphere vMotion.

Note The Geneve overlay requires an MTU value of 1600 bytes or greater.

Architecture and Design for VMware NSX-T for Workload Domains with Multiple Availability Zones

VMware, Inc. 21

Page 22: Architecture and Design for VMware NSX-T for …...Architecture and Design for VMware NSX-T for Workload Domains with Multiple Availability Zones 03 SEP 2019 VMware Validated Design

Table 3-4. Jumbo Frames Design Decisions

Decision ID Design Decision Design Justification Design Implication

NSXT-PHY-NET-008 Configure the MTU size to atleast 1600 bytes (9000recommended) on thephysical switch ports,vSphere Distributed Switches,vSphere Distributed Switchport groups, N-VDS switches,and physical network linkbetween availability zones,that support the followingtraffic types.

n Geneve (overlay)

n vSAN

n vMotion

n NFS

n vSphere Replication

Improves traffic throughput.

To support Geneve, increasethe MTU setting to a minimumof 1600 bytes.

When adjusting the MTUpacket size, you must alsoconfigure the entire networkpath (VMkernel ports, virtualswitches, physical switches,and routers) to support thesame MTU packet size.

Virtual Infrastructure Design for NSX-T WorkloadDomains with Multiple Availability ZonesThe virtual infrastructure design includes the NSX-T components that make up the virtual infrastructurelayer.

Figure 3-3. Virtual Infrastructure Layer in the SDDC

ServiceManagement

Portfolio Management

OperationsManagement

CloudManagement

Layer

Service Catalog

Self-Service Portal

Orchestration

BusinessContinuity

Fault Tolerance and Disaster

Recovery

Backup & Restore

Hypervisor

Pools of Resources

Virtualization Control

VirtualInfrastructure

Layer

Compute

Storage

Network

PhysicalLayer

Replication

Security and Compliance

Mapping to Regulations

Enhanced Guidance

Built-In Controls

n vSphere Cluster Design for NSX-T Workload Domains with Multiple Availability Zones

The cluster design must consider the workload that the cluster handles. Different cluster types in thisdesign have different characteristics.

Architecture and Design for VMware NSX-T for Workload Domains with Multiple Availability Zones

VMware, Inc. 22

Page 23: Architecture and Design for VMware NSX-T for …...Architecture and Design for VMware NSX-T for Workload Domains with Multiple Availability Zones 03 SEP 2019 VMware Validated Design

n vSAN Storage Design for NSX-T Workload Domains with Multiple Availability Zones

VMware vSAN Storage design includes network design, cluster and disk group design, and policydesign.

n Virtualization Network Design for NSX-T Workload Domains with Multiple Availability Zones

Design the virtualization network according to the business goals of your organization. Prevent alsounauthorized access, and provide timely access to business data.

n NSX Design for NSX-T Workload Domains with Multiple Availability Zones

This design implements software-defined networking by using VMware NSX-T. By using NSX-T,virtualization delivers for networking what it has already delivered for compute and storage.

vSphere Cluster Design for NSX-T Workload Domains withMultiple Availability ZonesThe cluster design must consider the workload that the cluster handles. Different cluster types in thisdesign have different characteristics.

vSphere Cluster Design Decision BackgroundWhen you design the cluster layout in vSphere, consider the following guidelines:

n Use fewer, larger ESXi hosts, or more, smaller ESXi hosts.

n A scale-up cluster has fewer, larger ESXi hosts.

n A scale-out cluster has more, smaller ESXi hosts.

n Compare the capital costs of purchasing fewer, larger ESXi hosts with the costs of purchasing more,smaller ESXi hosts. Costs vary between vendors and models.

n Evaluate the operational costs of managing a few ESXi hosts with the costs of managing more ESXihosts.

n Consider the purpose of the cluster.

n Consider the total number of ESXi hosts and cluster limits.

n vSphere High Availability Design for NSX-T Workload Domains with Multiple Availability Zones

VMware vSphere High Availability (vSphere HA) protects your virtual machines in case of ESXi hostfailure by restarting virtual machines on other hosts in the cluster when an ESXi host fails.

n Shared Edge and Compute Cluster Design for NSX-T Workload Domains with Multiple AvailabilityZones

Tenant workloads run on the ESXi hosts in the shared edge and compute cluster. Because of theshared nature of the cluster, NSX-T Edge appliances also run in this cluster. To support theseworkloads, you must determine the number of ESXi hosts and vSphere HA settings and severalother characteristics of the shared edge and compute cluster.

n Compute Cluster Design for NSX-T Workload Domains with Multiple Availability Zones

As the SDDC expands, you can add compute clusters.

Architecture and Design for VMware NSX-T for Workload Domains with Multiple Availability Zones

VMware, Inc. 23

Page 24: Architecture and Design for VMware NSX-T for …...Architecture and Design for VMware NSX-T for Workload Domains with Multiple Availability Zones 03 SEP 2019 VMware Validated Design

vSphere High Availability Design for NSX-T Workload Domains with MultipleAvailability ZonesVMware vSphere High Availability (vSphere HA) protects your virtual machines in case of ESXi hostfailure by restarting virtual machines on other hosts in the cluster when an ESXi host fails.

vSphere HA Design Basics

During configuration of the cluster, the ESXi hosts elect a master ESXi host. The master ESXi hostcommunicates with the vCenter Server system and monitors the virtual machines and secondary ESXihosts in the cluster.

The master ESXi host detects different types of failure:

n ESXi host failure, for example an unexpected power failure

n ESXi host network isolation or connectivity failure

n Loss of storage connectivity

n Problems with virtual machine OS availability

Table 3-5. vSphere HA Design Decisions

Decision ID Design Decision Design Justification Design Implication

NSXT-VI-VC-001 Use vSphere HA to protect allclusters against failures.

vSphere HA supports arobust level of protection forboth ESXi host and virtualmachine availability.

You must provide sufficientresources on the remaininghosts so that virtual machinescan be migrated to those hostsin the event of a host outage.

NSXT-VI-VC-002 Set vSphere HA HostIsolation Response to PowerOff.

vSAN requires that you setHA Isolation Response toPower Off to restart the virtualmachines on the availableESXi hosts.

VMs are powered off in case ofa false positive and an ESXihost is declared isolatedincorrectly.

vSphere HA Admission Control Policy Configuration

The vSphere HA Admission Control Policy allows an administrator to configure how the clusterdetermines available resources. In a smaller vSphere HA cluster, a larger proportion of the clusterresources are reserved to accommodate ESXi host failures, based on the selected policy.

Architecture and Design for VMware NSX-T for Workload Domains with Multiple Availability Zones

VMware, Inc. 24

Page 25: Architecture and Design for VMware NSX-T for …...Architecture and Design for VMware NSX-T for Workload Domains with Multiple Availability Zones 03 SEP 2019 VMware Validated Design

The following policies are available:

Host failures the clustertolerates

vSphere HA ensures that a specified number of ESXi hosts can fail andsufficient resources remain in the cluster to fail over all the virtual machinesfrom those ESXi hosts.

Percentage of clusterresources reserved

vSphere HA reserves a specified percentage of aggregate CPU andmemory resources for failover.

Specify Failover Hosts When an ESXi host fails, vSphere HA attempts to restart its virtualmachines on any of the specified failover ESXi hosts. If restart is notpossible, for example, the failover ESXi hosts have insufficient resources orhave failed as well, then vSphere HA attempts to restart the virtualmachines on other ESXi hosts in the cluster.

Shared Edge and Compute Cluster Design for NSX-T Workload Domains withMultiple Availability ZonesTenant workloads run on the ESXi hosts in the shared edge and compute cluster. Because of the sharednature of the cluster, NSX-T Edge appliances also run in this cluster. To support these workloads, youmust determine the number of ESXi hosts and vSphere HA settings and several other characteristics ofthe shared edge and compute cluster.

Table 3-6. Shared Edge and Compute Cluster Design Decisions

Decision ID Design Decision Design Justification Design Implication

NSXT-VI-VC-003 Create a shared edge andcompute cluster that containstenant workloads and NSX-TEdge appliances.

Limits the footprint of thedesign by saving the use of avSphere cluster specificallyfor the NSX-T Edge nodes.

In a shared cluster, the VLANsand subnets between theVMkernel ports for ESXi hostoverlay and the overlay ports ofthe edge appliances must beseparate.

NSXT-VI-VC-004 Configure Admission Controlfor percentage-based failoverbased on half of the ESXihosts in the cluster.

For example, in a cluster with8 ESXi hosts you configureadmission control for 4 ESXihosts failure and percentage-based failover capacity.

vSphere HA protects thetenant workloads and NSX-TEdge appliances in the eventof an ESXi host failure.vSphere HA powers on virtualmachines from the failedESXi hosts on any remainingESXi hosts.

Only half of a stretchedcluster should be used toensure that all VMs haveenough resources in anavailability zone outage.

You must add ESXi hosts tothe cluster in pairs, one in eachavailability zone.

Architecture and Design for VMware NSX-T for Workload Domains with Multiple Availability Zones

VMware, Inc. 25

Page 26: Architecture and Design for VMware NSX-T for …...Architecture and Design for VMware NSX-T for Workload Domains with Multiple Availability Zones 03 SEP 2019 VMware Validated Design

Table 3-6. Shared Edge and Compute Cluster Design Decisions (continued)

Decision ID Design Decision Design Justification Design Implication

NSXT-VI-VC-005 Create a shared edge andcompute cluster that consistsof a minimum of eight ESXihosts, four in each availabilityzone.

Allocating 4 ESXi hostsprovides full redundancy foreach availability zone withinthe cluster.

Having 4 ESXi hosts in eachavailability zone guaranteesvSAN and NSX redundancyduring availability zoneoutages or maintenanceoperations.

8 ESXi hosts is the smalleststarting point when using twoavailability zones for theshared edge and computecluster for redundancy andperformance thus increasingcost.

NSXT-VI-VC-006 Create a resource pool for thefour large sized edge virtualmachines, two per availabilityzone, with a CPU share levelof High, a memory share ofnormal, and a 128-GBmemory reservation.

The NSX-T Edge appliancescontrol all network traffic inand out of the SDDC. In acontention situation, theseappliances must receive allthe resources required.

During contention, the NSX-Tcomponents receive moreresources than the otherworkloads. As a result,monitoring and capacitymanagement must be aproactive activity.

The resource pool memoryreservation must be expandedif you plan to deploy moreNSX-T Edge appliances.

NSXT-VI-VC-007 Create a resource pool for alltenant workloads with a CPUshare value of Normal and amemory share value ofNormal.

Running virtual machines atthe cluster level has anegative impact on all othervirtual machines duringcontention. To avoid animpact on networkconnectivity, in a shared edgeand compute cluster, theNSX-T Edge appliances mustreceive resources with priorityto the other workloads.Setting the share values toNormal increases theresource shares of the NSX-TEdge appliances in thecluster.

During contention, tenantworkloads might haveinsufficient resources and havepoor performance. Proactivelyperform monitoring andcapacity management, addcapacity or dedicate an edgecluster before contentionoccurs.

Architecture and Design for VMware NSX-T for Workload Domains with Multiple Availability Zones

VMware, Inc. 26

Page 27: Architecture and Design for VMware NSX-T for …...Architecture and Design for VMware NSX-T for Workload Domains with Multiple Availability Zones 03 SEP 2019 VMware Validated Design

Table 3-6. Shared Edge and Compute Cluster Design Decisions (continued)

Decision ID Design Decision Design Justification Design Implication

NSXT-VI-VC-008 Create a host profile for eachavailability zone in the cluster.

Using host profiles simplifiesthe configuration of ESXihosts and ensures thatsettings are uniform acrossthe cluster.

After NSX-T has beendeployed you must update thehost profile.

Anytime an authorized changeto an ESXi host is made, youmust update the host profile toreflect the change or the statuswill show non-compliant.

Because of configurationdifferences between availabilityzones, two host profiles arerequired and must be appliedon each ESXi host.

NSXT-VI-VC-009 Set the cluster isolationaddresses for the cluster tothe gateway IP address forthe vSAN network in bothavailability zones.

Allows vSphere HA tovalidate complete networkisolation in the case of aconnection failure betweenavailability zones.

You must manually configurethe isolation address.

NSXT-VI-VC-010 Set the advanced clustersettingdas.usedefaultisolationaddress to false.

Ensures that the manualisolation addresses are usedinstead of the defaultmanagement networkgateway address.

None.

Compute Cluster Design for NSX-T Workload Domains with MultipleAvailability ZonesAs the SDDC expands, you can add compute clusters.

Tenant workloads run on the ESXi hosts in the compute cluster instances. One Compute vCenter Serverinstance manages multiple compute clusters. The design determines vSphere HA settings for thecompute cluster.

Decision ID Design Decision Design Justification Design Implication

NSXT-VI-VC-011 Configure vSphere HA to usepercentage-based failovercapacity to ensure n+1availability.

Using explicit host failoverlimits the total availableresources in a cluster.

The resources of one ESXihost in the cluster is reservedwhich can cause provisioningto fail if resources areexhausted.

Architecture and Design for VMware NSX-T for Workload Domains with Multiple Availability Zones

VMware, Inc. 27

Page 28: Architecture and Design for VMware NSX-T for …...Architecture and Design for VMware NSX-T for Workload Domains with Multiple Availability Zones 03 SEP 2019 VMware Validated Design

vSAN Storage Design for NSX-T Workload Domains with MultipleAvailability ZonesVMware vSAN Storage design includes network design, cluster and disk group design, and policy design.

n vSAN Network Design for NSX-T Workload Domains with Multiple Availability Zones

When you plan your network configuration, consider the overall traffic and decide how to isolatevSAN traffic.

n vSAN Cluster and Disk Group Design for NSX-T Workload Domains with Multiple Availability Zones

When considering the cluster and disk group design, decide on the vSAN datastore size, number ofESXi hosts per cluster, number of disk groups per ESXi host, and the vSAN policy.

n vSAN Policy Design for NSX-T Workload Domains with Multiple Availability Zones

After you enable and configure VMware vSAN, you can create storage policies that define the virtualmachine storage characteristics. Storage characteristics specify different levels of service fordifferent virtual machines.

vSAN Network Design for NSX-T Workload Domains with Multiple AvailabilityZonesWhen you plan your network configuration, consider the overall traffic and decide how to isolate vSANtraffic.

vSAN Network Considerations

In case of two availability zones, the management VLAN in each availability zone, which the NSX-T Edgedevices management interface connects to, must be stretched across both availability zones. Thetechnology used to stretch the VLAN is out of scope and varies according to your existing infrastructure.

The network infrastructure between availability zones must support jumbo frames, and ensure thatlatency is less than 5 ms round trip.

Architecture and Design for VMware NSX-T for Workload Domains with Multiple Availability Zones

VMware, Inc. 28

Page 29: Architecture and Design for VMware NSX-T for …...Architecture and Design for VMware NSX-T for Workload Domains with Multiple Availability Zones 03 SEP 2019 VMware Validated Design

Figure 3-4. VMware vSAN Conceptual Network with Two Availability Zones

ESXi Host ESXi Host ESXi Host

ESXi Host ESXi Host

Stretched vSAN Datastore

vSAN Stretched Clusters

vSAN Network (VLAN)

Availability Zone 2 Stretched Management Network (VLAN)

vMotion Network (VLAN)

ESXi Host ESXi Host ESXi Host

ESXi Host ESXi Host

vSAN Network (VLAN)

vMotion Network (VLAN)

Host TEP Network (VLAN)

Virtual Machine Network(s) (Overlay)

Host TEP Network (VLAN)

Availability Zone 1 Stretched Management Network (VLAN)

Network Requirements

Use a minimum of a 10 Gbps Ethernet connection, with 25 Gbps Ethernet recommended, for use withvSAN to ensure the best and most predictable performance (IOPS) for the environment. If you use aslower connection, a significant decrease in array performance appears.

A minimum of 10 Gbps Ethernet also provides support for the use of a vSAN all-flash configurations.

vSAN supports jumbo frames for vSAN traffic. A vSAN design must use jumbo frames only if the physicalenvironment is already configured to support them, they are part of the existing design, or if theunderlying configuration does not create a significant amount of added complexity to the design.

Isolate vSAN traffic on its own VLAN. When a design uses multiple vSAN clusters, each cluster must usea dedicated VLAN or segment for its traffic. This approach prevents interference between clusters andhelps with troubleshooting cluster configuration.

In a stretched cluster configuration, vSAN requires a 5ms or less round trip latency between ESXi Hostsin each availability zone and 200ms between each ESXi host in each availability zone to the witnessappliance.

Architecture and Design for VMware NSX-T for Workload Domains with Multiple Availability Zones

VMware, Inc. 29

Page 30: Architecture and Design for VMware NSX-T for …...Architecture and Design for VMware NSX-T for Workload Domains with Multiple Availability Zones 03 SEP 2019 VMware Validated Design

Table 3-7. Network Design Decisions for vSAN Stretched Cluster

Decision ID Design Decision Design Justification Design Implication

NSXT-VI-Storage-SDS-001 Use a minimum of 10 GbpsEthernet (25 Gbps Ethernetrecommended) for vSANtraffic.

Performance with 10 GbpsEthernet is sufficient, whilewith 25 Gbps Ethernet isoptimal. If the bandwidth isless than 10 Gbps Ethernet,array performancesignificantly decreases.

The physical network mustsupport 10 Gb or 25 Gbnetworking between everyESXi host in the vSAN cluster.

NSXT-VI-Storage-SDS-002 Configure jumbo frames onthe VLANs dedicated to vSANtraffic.

Jumbo frames are alreadyused to improve performanceof vSphere vMotion and NFSstorage traffic.

Every device in the networkmust support jumbo frames.

NSXT-VI-Storage-SDS-003 Configure a dedicated VLANin each availability zone, foreach vSAN enabled cluster.

VLANs provide trafficisolation.

vSAN traffic betweenavailability zones is routed.An additional stretched VLANis not required.

You have enough VLANs withineach cluster and you can usethem for traffic segregation.

Static routes on the ESXi hostsare required.

vSAN Witness

When you use vSAN in a stretched cluster configuration, you must configure a vSAN stretched clusterwitness host. This ESXi host must be configured in a third location that is not local to the ESXi hosts oneither side of the stretched cluster.

This vSAN witness can be configured as a physical ESXi host or you can use the vSAN witnessappliance.

Table 3-8. Design Decisions on the vSAN Witness

Decision ID Design Decision Design Justification Design Implication

NSXT-VI-Storage-SDS-004 Deploy the vSAN witnessappliance in a third physicallocation.

A location outside of bothavailability zones is requiredto provide an appropriatequorum.

A third physically separatelocation is required whenimplementing a vSANstretched cluster between twolocations.

NSXT-VI-Storage-SDS-005 Each availability zone musthave a unique route to thethird physical location.

This ensures connectivity toeach physical location in theevent of an availability zonefailure.

You can not route witnesstraffic from one availability zonethrough another.

vSAN Cluster and Disk Group Design for NSX-T Workload Domains withMultiple Availability ZonesWhen considering the cluster and disk group design, decide on the vSAN datastore size, number of ESXihosts per cluster, number of disk groups per ESXi host, and the vSAN policy.

Architecture and Design for VMware NSX-T for Workload Domains with Multiple Availability Zones

VMware, Inc. 30

Page 31: Architecture and Design for VMware NSX-T for …...Architecture and Design for VMware NSX-T for Workload Domains with Multiple Availability Zones 03 SEP 2019 VMware Validated Design

vSAN Datastore Size

The size of the vSAN datastore depends on the requirements for the datastore. Consider cost versusavailability to provide the appropriate sizing.

Table 3-9. Design Decisions on the vSAN Datastore

Decision ID Design Decision Design Justification Design Implication

NSXT-VI-Storage-SDS-006 On all vSAN datastores,ensure at least 30% of freespace is always available.

When vSAN reaches 80%usage, a rebalance task isstarted which can beresource-intensive.

Increases the amount ofavailable storage needed.

Number of ESXi Hosts Per Cluster

The number of ESXi hosts in the cluster depends on these factors:

n Amount of available space on the vSAN datastore

n Number of failures you can tolerate in the cluster

For example, if the vSAN cluster has only 3 ESXi hosts, only a single failure is supported. If a higher levelof availability is required, additional hosts are required.

Cluster Size Design Background

Design Quality 3 ESXi Hosts32 ESXiHosts

64 ESXiHosts Comments

Availability ↓ ↑ ↑↑ The more ESXi hosts in the cluster, the more failures thecluster can tolerate.

Manageability ↓ ↑ ↑ The more ESXi hosts in the cluster, the more virtual machinescan run in the vSAN environment.

Performance ↑ ↓ ↓ A larger cluster can impact performance if there is animbalance of resources. Consider performance as you makeyour decision.

Recoverability o o o Neither design option impacts recoverability.

Security o o o Neither design option impacts security.

Legend: ↑ = positive impact on quality; ↓ = negative impact on quality; o = no impact on quality.

Table 3-10. Design Decision on the Cluster Size for vSAN

Decision ID Design Decision Design Justification Design Implication

NSXT-VI-Storage-SDS-007 Two Availability Zonesrequires a cluster with aminimum of 8 ESXi hosts (4in each availability zone) tosupport a stretched vSANconfiguration.

Having 8 ESXi hostsaddresses the availability andsizing requirements, andallows you to take anavailability zone offline formaintenance or upgradeswithout impacting the overallvSAN cluster health.

The availability requirementsfor the cluster might causeunderutilization of the cluster'sESXi hosts.

Architecture and Design for VMware NSX-T for Workload Domains with Multiple Availability Zones

VMware, Inc. 31

Page 32: Architecture and Design for VMware NSX-T for …...Architecture and Design for VMware NSX-T for Workload Domains with Multiple Availability Zones 03 SEP 2019 VMware Validated Design

Number of Disk Groups Per ESXi Host

Disk group sizing is an important factor during volume design.

n If more ESXi hosts are available in the cluster, more failures are tolerated in the cluster. Thiscapability adds cost because additional hardware for the disk groups is required.

n More available disk groups can increase the recoverability of vSAN during a failure.

Consider the following data points when deciding on the number of disk groups per ESXi host:

n Amount of available space on the vSAN datastore

n Number of failures you can tolerate in the cluster

The optimal number of disk groups is a balance between hardware and space requirements for the vSANdatastore. More disk groups increase space and provide higher availability. However, adding disk groupscan be cost-prohibitive.

Disk Groups Design Background

The number of disk groups can affect availability and performance.

Design Quality1 DiskGroup

3 DiskGroups

5 DiskGroups Comments

Availability ↓ ↑ ↑↑ The more ESXi hosts in the cluster, the more failures the clustercan tolerate.

The capability adds cost because you need additional hardwarefor the disk groups.

Manageability o o o With more ESXi hosts in the cluster, you can manage morevirtual machines in the vSAN environment.

Performance o ↑ ↑↑ If the flash percentage ratio to storage capacity is large, vSANcan deliver increased performance and speed.

Recoverability o ↑ ↑↑ More available disk groups can increase the recoverability ofvSAN during a failure.

Rebuilds complete faster because of more places to place dataand to copy data from.

Security o o o Neither design option impacts security.

Legend: ↑ = positive impact on quality; ↓ = negative impact on quality; o = no impact on quality.

Decision ID Design Decision Design Justification Design Implication

NSXT-VI-Storage-SDS-008

Configure vSAN with aminimum of one diskgroup per ESXi host.

Single disk group provides a costeffective solution with the minimumrequired performance and usablespace for the datastore.

If an SSD in an ESXi host becomesunavailable, the host takes the disk groupoffline.

If you use two or more disk groups, you canincrease availability and performance.

Architecture and Design for VMware NSX-T for Workload Domains with Multiple Availability Zones

VMware, Inc. 32

Page 33: Architecture and Design for VMware NSX-T for …...Architecture and Design for VMware NSX-T for Workload Domains with Multiple Availability Zones 03 SEP 2019 VMware Validated Design

vSAN Policy Design for NSX-T Workload Domains with Multiple AvailabilityZonesAfter you enable and configure VMware vSAN, you can create storage policies that define the virtualmachine storage characteristics. Storage characteristics specify different levels of service for differentvirtual machines.

The default storage policy tolerates a single failure and has a single disk stripe. If you configure a custompolicy, vSAN must guarantee its application. However, if vSAN cannot guarantee a policy, you cannotprovision a virtual machine that uses the policy, unless you enable force provisioning.

VMware vSAN Policy Options

A storage policy includes several attributes, which can be used alone or combined to provide differentservice levels. Policies can be configured for availability and performance conservatively, to balance theconsumed space and recoverability properties. In most scenarios, the default system policy is adequateand you do not need additional policies. Policies allow any configuration to be as customized as neededfor the business requirements of the application .

Policy Design Background

Before you make design decisions, understand the policies and the objects to which they can be applied.The policy options are listed in the table.

Architecture and Design for VMware NSX-T for Workload Domains with Multiple Availability Zones

VMware, Inc. 33

Page 34: Architecture and Design for VMware NSX-T for …...Architecture and Design for VMware NSX-T for Workload Domains with Multiple Availability Zones 03 SEP 2019 VMware Validated Design

Table 3-11. VMware vSAN Policy Options

Capability Use Case Default Value Maximum Value Comments

Number of failures totolerate

Redundancy 1 3 A standard RAID 1mirrored configurationthat providesredundancy for a virtualmachine disk. Thehigher the value, themore failures can betolerated. For n failurestolerated, n+1 copies ofthe disk are created, and2n+1 ESXi hostscontributing storage arerequired.

A higher n valueindicates that morereplicas of virtualmachines are made,which can consumemore disk space thanexpected.

Number of disk stripesper object

Performance 1 12 Use a standard RAID 0stripe configuration toincrease performancefor a virtual machinedisk.

The setting defines thenumber of HDDs onwhich each replica of astorage object is striped.

If the value is higherthan 1, you get anincreased performance.However you can alsoget an increase insystem resource usage.

Architecture and Design for VMware NSX-T for Workload Domains with Multiple Availability Zones

VMware, Inc. 34

Page 35: Architecture and Design for VMware NSX-T for …...Architecture and Design for VMware NSX-T for Workload Domains with Multiple Availability Zones 03 SEP 2019 VMware Validated Design

Table 3-11. VMware vSAN Policy Options (continued)

Capability Use Case Default Value Maximum Value Comments

Flash read cachereservation (%)

Performance 0% 100% Flash capacity reservedas read cache for thestorage is a percentageof the logical object sizethat is reserved for thatobject.

Only use the setting forworkloads if you mustaddress readperformance issues. Thedownside is that otherobjects cannot use areserved cache.

VMware recommends tonot use thesereservations unless it isabsolutely necessarybecause unreservedflash is shared fairlyamong all objects.

Architecture and Design for VMware NSX-T for Workload Domains with Multiple Availability Zones

VMware, Inc. 35

Page 36: Architecture and Design for VMware NSX-T for …...Architecture and Design for VMware NSX-T for Workload Domains with Multiple Availability Zones 03 SEP 2019 VMware Validated Design

Table 3-11. VMware vSAN Policy Options (continued)

Capability Use Case Default Value Maximum Value Comments

Object space reservation(%)

Thick provisioning 0% 100% The percentage of thestorage object to bethick provisioned uponVM creation. The rest ofthe storage is thinprovisioned.

This setting is useful if apredictable amount ofstorage can always befilled by an object cuttingback on repeatable diskgrowth operations for allbut new or non-predictable storage use.

Force provisioning Override policy No - The setting forcesprovisioning to occureven if the currentlyavailable clusterresources cannot satisfythe current policy.

The setting is useful incase of a plannedexpansion of the vSANcluster, during whichprovisioning of VMsmust continue. VMwarevSAN tries to bring theobject to compliance asresources becomeavailable.

By default, policies are configured based on application requirements. However, you apply themdifferently per object.

Table 3-12. Object Policy Defaults

Object Policy Comments

Virtual machine namespace Failures to tolerate: 1 Configurable. Changes are notrecommended.

Swap Failures to tolerate: 1 Configurable. Changes are notrecommended.

Architecture and Design for VMware NSX-T for Workload Domains with Multiple Availability Zones

VMware, Inc. 36

Page 37: Architecture and Design for VMware NSX-T for …...Architecture and Design for VMware NSX-T for Workload Domains with Multiple Availability Zones 03 SEP 2019 VMware Validated Design

Table 3-12. Object Policy Defaults (continued)

Object Policy Comments

Virtual disks User-configured storage policy Can be any storage policy configured onthe system.

Virtual disk snapshots Uses virtual disk policy Same as virtual disk policy by default.Changes are not recommended.

Note If you do not specify a user-configured policy, vSAN uses a default system policy of 1 failure totolerate and 1 disk stripe for virtual disks and virtual disk snapshots. To ensure protection for these criticalvirtual machine components, policy defaults for the VM namespace and swap are set statically and arenot configurable. Configure policies according to the business requirements of the application. By usingpolicies, vSAN can adjust the performance of a disk on demand.

Policy Design Recommendations

Policy design starts with assessment of business needs and application requirements. Assess use casesfor VMware vSAN to determine the necessary policies. First, assess the following applicationrequirements:

n I/O performance and profile of your workloads on a per-virtual-disk basis

n Working sets of your workloads

n Hot-add of additional cache (requires repopulation of cache)

n Specific application best practice (such as block size)

After assessment, configure the software-defined storage module policies for availability and performancein a conservative manner so that you balance consumed space and recoverability. Default system policymight be adequate and you might not need additional policies, unless you have specific requirements forperformance or availability.

Architecture and Design for VMware NSX-T for Workload Domains with Multiple Availability Zones

VMware, Inc. 37

Page 38: Architecture and Design for VMware NSX-T for …...Architecture and Design for VMware NSX-T for Workload Domains with Multiple Availability Zones 03 SEP 2019 VMware Validated Design

Decision ID Design Decision Design Justification Design Implication

NSXT-VI-Storage-SDS-009 For vSAN Stretched clusters,edit the default VMware vSANstorage policy and change theSite Disaster Tolerancesetting from None to Dual SiteMirroring (stretched cluster).

Provides protection for virtualmachines in each availabilityzone, with the ability torecover from an availabilityzone outage.

You might need additionalpolicies if third-party VMs mustbe hosted in these clusters dueto performance or availabilityrequirements that differ fromwhat the default VMware vSANpolicy supports.

NSXT-VI-Storage-SDS-010 Leave the default virtualmachine swap file as asparse object on VMwarevSAN.

Creates virtual swap files as asparse object on the vSANdatastore. Sparse virtualswap files only consumecapacity on vSAN whenaccessed. As a result, youcan reduce the consumptionon the vSAN datastore ifvirtual machines do notexperience memory over-commitment which requiresthe use of the virtual swapfile.

None.

Virtualization Network Design for NSX-T Workload Domains withMultiple Availability ZonesDesign the virtualization network according to the business goals of your organization. Prevent alsounauthorized access, and provide timely access to business data.

This network virtualization design uses vSphere and NSX-T to implement virtual networking.

n Virtual Network Design Guidelines for NSX-T Workload Domains with Multiple Availability Zones

This VMware Validated Design follows high-level network design guidelines and networking bestpractices.

n Virtual Switches for NSX-T Workload Domains with Multiple Availability Zones

Virtual switches simplify the configuration process by providing single pane of glass view forperforming virtual network management tasks.

n NIC Teaming for NSX-T Workload Domains with Multiple Availability Zones

You can use NIC teaming to increase the network bandwidth available in a network path, and toprovide the redundancy that supports higher availability.

n Geneve Overlay for NSX-T Workload Domains with Multiple Availability Zones

Geneve provides the overlay capability in NSX-T to create isolated, multi-tenant broadcast domainsacross data center fabrics, and enables customers to create elastic, logical networks that spanphysical network boundaries.

Architecture and Design for VMware NSX-T for Workload Domains with Multiple Availability Zones

VMware, Inc. 38

Page 39: Architecture and Design for VMware NSX-T for …...Architecture and Design for VMware NSX-T for Workload Domains with Multiple Availability Zones 03 SEP 2019 VMware Validated Design

n vMotion TCP/IP Stack for NSX-T Workload Domains with Multiple Availability Zones

Use the vMotion TCP/IP stack to isolate traffic for vSphere vMotion and to assign a dedicateddefault gateway for vSphere vMotion traffic.

Virtual Network Design Guidelines for NSX-T Workload Domains withMultiple Availability ZonesThis VMware Validated Design follows high-level network design guidelines and networking bestpractices.

Design Goals

You can apply the following high-level design goals to your environment:

n Meet diverse needs. The network must meet the diverse needs of many different entities in anorganization. These entities include applications, services, storage, administrators, and users.

n Reduce costs. Server consolidation alone reduces network costs by reducing the number of requirednetwork ports and NICs, but you should determine a more efficient network design. For example,configuring two 25 GbE NICs with VLANs might be more cost effective than configuring a dozen 1-GbE NICs on separate physical networks.

n Boost performance. You can achieve performance improvements and decrease the time required toperform maintenance by providing sufficient bandwidth, which reduces contention and latency.

n Improve availability. You usually improve availability by providing network redundancy.

n Support security. You can support an acceptable level of security through controlled access whererequired and isolation where necessary.

n Improve infrastructure functionality. You can configure the network to support vSphere features suchas vSphere vMotion, vSphere High Availability, and vSphere Fault Tolerance.

Best Practices

Follow the networking best practices throughout your environment.

n Separate network services from one another for greater security and better performance.

n Use Network I/O Control and traffic shaping to guarantee bandwidth to critical virtual machines.During network contention, these critical virtual machines receive a higher percentage of thebandwidth.

n Separate network services on an NSX-T Virtual Distributed Switch (N-VDS) by attaching them tosegments with different VLAN IDs.

n Keep vSphere vMotion traffic on a separate network. When migration with vMotion occurs, thecontents of the memory of the guest operating system is transmitted over the network. You can placevSphere vMotion on a separate network by using a dedicated vSphere vMotion VLAN.

n When using pass-through devices with Linux kernel version 2.6.20 or an earlier guest OS, avoid MSIand MSI-X modes. These modes have significant performance impact.

n For best performance, use VMXNET3 virtual machine NICs.

Architecture and Design for VMware NSX-T for Workload Domains with Multiple Availability Zones

VMware, Inc. 39

Page 40: Architecture and Design for VMware NSX-T for …...Architecture and Design for VMware NSX-T for Workload Domains with Multiple Availability Zones 03 SEP 2019 VMware Validated Design

n Ensure that physical network adapters connected to the same virtual switch are also connected to thesame physical network.

Network Segmentation and VLANs

You separate different types of traffic for access security and to reduce contention and latency.

High latency on a network can impact performance. Some components are more sensitive to high latencythan others. For example, reducing latency is important on the IP storage and the vSphere FaultTolerance logging network, because latency on these networks can negatively affect the performance ofmultiple virtual machines.

According to the application or service, high latency on specific virtual machine networks can alsonegatively affect performance. Use information gathered from the current state analysis and frominterviews with key stakeholder and SMEs to determine which workloads and networks are especiallysensitive to high latency.

Virtual Networks

Determine the number of networks or VLANs that are required according to the type of traffic.

n vSphere operational traffic.

n Management

n Geneve (overlay)

n vMotion

n vSAN

n NFS Storage

n vSphere Replication

n Traffic that supports the services and applications of the organization.

Virtual Switches for NSX-T Workload Domains with Multiple AvailabilityZonesVirtual switches simplify the configuration process by providing single pane of glass view for performingvirtual network management tasks.

n Virtual Switch Design Background for NSX-T Workload Domains with Multiple Availability Zones

vSphere Distributed Switch and NSX-T Virtual Distributed Switch (N-VDS) provide severaladvantages over vSphere Standard Switch.

n Virtual Switch Design Decisions for NSX-T Workload Domains with Multiple Availability Zones

The virtual switch design decisions determine the use and placement of specific switch types.

n Shared Edge and Compute Cluster Switches for NSX-T Workload Domains with Multiple AvailabilityZones

The shared edge and compute cluster uses a single N-VDS with a certain configuration for handledtraffic types, NIC teaming, and MTU size.

Architecture and Design for VMware NSX-T for Workload Domains with Multiple Availability Zones

VMware, Inc. 40

Page 41: Architecture and Design for VMware NSX-T for …...Architecture and Design for VMware NSX-T for Workload Domains with Multiple Availability Zones 03 SEP 2019 VMware Validated Design

Virtual Switch Design Background for NSX-T Workload Domains with Multiple AvailabilityZones

vSphere Distributed Switch and NSX-T Virtual Distributed Switch (N-VDS) provide several advantagesover vSphere Standard Switch.

Centralizedmanagement

n A distributed switch is created and centrally managed on a vCenterServer system. The switch configuration is consistent across ESXihosts.

n An N-VDS is created and centrally managed in NSX-T Manager. Theswitch configuration is consistent across ESXi and edge transportnodes.

Centralized management saves time and reduces mistakes and operationalcosts.

Additional features Some of the features of distributed switches can be useful to theapplications and services running in the organization’s infrastructure. Forexample, NetFlow and port mirroring provide monitoring andtroubleshooting capabilities to the virtual infrastructure.

Consider the following caveats for distributed switches:

n Distributed switches are manageable only when the vCenter Server instance is available. As a result,vCenter Server becomes a Tier-1 application.

n N-VDS instances are manageable only when the NSX-T Manager cluster is available. As a result, theNSX-T Manager cluster becomes a Tier-1 application.

Virtual Switch Design Decisions for NSX-T Workload Domains with Multiple AvailabilityZones

The virtual switch design decisions determine the use and placement of specific switch types.

Decision ID Design Decision Design Justification Design Implication

NSXT-VI-NET-001 Use N-VDS for the NSX-Tbased shared edge andcompute cluster, and foradditional NSX-T basedcompute clusters.

The N-VDS is required foroverlay traffic.

Management is shifted fromthe vSphere Client to the NSXManager.

Shared Edge and Compute Cluster Switches for NSX-T Workload Domains with MultipleAvailability Zones

The shared edge and compute cluster uses a single N-VDS with a certain configuration for handled traffictypes, NIC teaming, and MTU size.

Architecture and Design for VMware NSX-T for Workload Domains with Multiple Availability Zones

VMware, Inc. 41

Page 42: Architecture and Design for VMware NSX-T for …...Architecture and Design for VMware NSX-T for Workload Domains with Multiple Availability Zones 03 SEP 2019 VMware Validated Design

Figure 3-5. Virtual Switch Design for ESXi Hosts in the Shared Edge and Compute Cluster

nic0 nic1

VLAN NFS

VLAN vMotion

VLAN vSAN

Sample ESXi Shared Edge and Compute Host

sfo01-w-nvds01

VLAN ESXi Management

VLAN Trunking Uplink01

VLAN Trunking Uplink02

VLAN ESXi Overlay (Host TEP)

VLAN Trunking Edge Overlay (Edge TEP)

Table 3-13. Virtual Switches for the Shared Edge and Compute Cluster

N-VDS Switch Name FunctionNumber of PhysicalNIC Ports Teaming Policy MTU

sfo01-w-nvds01 n ESXi Management

n vSphere vMotion

n vSAN

n NFS

n Geneve Overlay(TEP)

n Uplink trunking (2)for the NSX-TEdge instances

2 n Load balancesource for the ESXitraffic

n Failover order forthe edge VM traffic

9000

sfo01-w-uplink01 n Uplink to enableECMP

1 Failover order 9000

sfo01-w-uplink02 n Uplink to enableECMP

1 Failover order 9000

Architecture and Design for VMware NSX-T for Workload Domains with Multiple Availability Zones

VMware, Inc. 42

Page 43: Architecture and Design for VMware NSX-T for …...Architecture and Design for VMware NSX-T for Workload Domains with Multiple Availability Zones 03 SEP 2019 VMware Validated Design

Table 3-14. Virtual Switches in the Shared Edge and Compute Cluster by Physical NIC

N-VDS Switch vmnic Function

sfo01-w-nvds01 0 Uplink

sfo01-w-nvds01 1 Uplink

Figure 3-6. Segment Configuration on an ESXi Host That Runs an NSX-T Edge Node

NSX-T Edge Virtual Machine

fp-eth0 (overlay)

sfo01-w-uplink01(VLAN)

fp-eth1 (uplink 1)

fp-eth2 (uplink 2)

eth0 (management)

ESXi Host

sfo01-w-nvds01

vmnic0

vmnic1

sfo01-w-nvds01(Overlay)

sfo01-w-uplink02(VLAN)

sfo01-w-nvds01-uplink01(VLAN Trunking)

sfo01-w-overlay(VLAN Trunking)

sfo01-w-nvds01-uplink02(VLAN Trunking)

sfo01-w-nvds01-management(VLAN 1641)

Table 3-15. Segments in the Shared Edge and Compute Cluster

N-VDS Switch Segment Name

sfo01-w-nvds01 sfo01-w-nvds01-management

sfo01-w-nvds01 sfo01-w-nvds01-vmotion

sfo01-w-nvds01 sfo01-w-nvds01-vsan

sfo01-w-nvds01 sfo01-w-nvds01-overlay

sfo01-w-nvds01 sfo01-w-nvds01-uplink01

sfo01-w02-uplink01 sfo01-w02-uplink01

sfo01-w02-uplink02 sfo01-w02-uplink02

sfo01-w-nvds01 sfo02-w-nvds01-management

sfo01-w-nvds01 sfo02-w-nvds01-vmotion

sfo01-w-nvds01 sfo02-w-nvds01-vsan

sfo01-w-nvds01 sfo02-w-nvds01-nfs

sfo02-w02-uplink01 sfo02-w02-uplink01

sfo02-w02-uplink02 sfo02-w02-uplink02

Architecture and Design for VMware NSX-T for Workload Domains with Multiple Availability Zones

VMware, Inc. 43

Page 44: Architecture and Design for VMware NSX-T for …...Architecture and Design for VMware NSX-T for Workload Domains with Multiple Availability Zones 03 SEP 2019 VMware Validated Design

Table 3-16. VMkernel Adapters for the Shared Edge and Compute Cluster

N-VDS Switch Segment Name Enabled Services

sfo01-w-nvds01 sfo01-w-nvds01-management Management Traffic

sfo01-w-nvds01 sfo01-w-nvds01-vmotion vMotion Traffic

sfo01-w-nvds01 sfo01-w-nvds01-vsan vSAN

sfo01-w-nvds01 sfo01-w-nvds01-nfs --

sfo01-w-nvds01 sfo02-w-nvds01-management Management Traffic

sfo01-w-nvds01 sfo02-w-nvds01-vmotion vMotion Traffic

sfo01-w-nvds01 sfo02-w-nvds01-vsan vSAN

sfo01-w-nvds01 sfo02-w-nvds01-nfs --

sfo01-w-nvds01 auto created (Host TEP) --

sfo01-w-nvds01 auto created (Host TEP) --

sfo01-w-nvds01 auto created (Hyperbus) --

Note

When the NSX-T Edge appliance is on an N-VDS, it must use a different VLAN ID and subnet from theESXi hosts overlay (TEP) VLAN ID and subnet.

ESXi host TEP VMkernel ports are automatically created when you configure an ESXi host as a transportnode.

NIC Teaming for NSX-T Workload Domains with Multiple Availability ZonesYou can use NIC teaming to increase the network bandwidth available in a network path, and to providethe redundancy that supports higher availability.

Benefits and Overview

NIC teaming helps avoid a single point of failure and provides options for load balancing of traffic. Toreduce further the risk of a single point of failure, build NIC teams by using ports from multiple NIC andmotherboard interfaces.

Create a single virtual switch with teamed NICs across separate physical switches.

NIC Teaming Design Background

For a predictable level of performance, use multiple network adapters in one of the followingconfigurations.

n An active-passive configuration that uses explicit failover when connected to two separate switches.

n An active-active configuration in which two or more physical NICs in the server are assigned theactive role.

Architecture and Design for VMware NSX-T for Workload Domains with Multiple Availability Zones

VMware, Inc. 44

Page 45: Architecture and Design for VMware NSX-T for …...Architecture and Design for VMware NSX-T for Workload Domains with Multiple Availability Zones 03 SEP 2019 VMware Validated Design

This validated design uses a non-LAG active-active configuration using the route based on physical NICload algorithm for vSphere Distributed Switch and load balance source algorithm for N-VDS. By using thisconfiguration, network cards remain active instead of remaining idle until a failure occurs.

Table 3-17. NIC Teaming and Policy

Design Quality Active-Active Active-Passive Comments

Availability ↑ ↑ Using teaming regardless ofthe option increases theavailability of the environment.

Manageability o o Neither design option impactsmanageability.

Performance ↑ o An active-active configurationcan send traffic across eitherNIC, thereby increasing theavailable bandwidth. Thisconfiguration provides a benefitif the NICs are being sharedamong traffic types andNetwork I/O Control is used.

Recoverability o o Neither design option impactsrecoverability.

Security o o Neither design option impactssecurity.

Legend: ↑ = positive impact on quality; ↓ = negative impact on quality; o = no impact on quality.

Table 3-18. NIC Teaming Design Decisions

Decision ID Design Decision Design Justification Design Implication

NSXT-VI-NET-002 In the shared edge andcompute cluster, use the Loadbalance source teamingpolicy on N-VDS.

NSX-T Virtual DistributedSwitch(N-VDS) supports Loadbalance source and Failoverteaming policies. When youuse the Load balance sourcepolicy, both physical NICs canbe active and carry traffic.

None.

Geneve Overlay for NSX-T Workload Domains with Multiple AvailabilityZonesGeneve provides the overlay capability in NSX-T to create isolated, multi-tenant broadcast domainsacross data center fabrics, and enables customers to create elastic, logical networks that span physicalnetwork boundaries.

Architecture and Design for VMware NSX-T for Workload Domains with Multiple Availability Zones

VMware, Inc. 45

Page 46: Architecture and Design for VMware NSX-T for …...Architecture and Design for VMware NSX-T for Workload Domains with Multiple Availability Zones 03 SEP 2019 VMware Validated Design

The first step in creating these logical networks is to isolate and pool the networking resources. By usingthe Geneve overlay, NSX-T isolates the network into a pool of capacity and separates the consumption ofthese services from the underlying physical infrastructure. This model is similar to the model vSphereuses to abstract compute capacity from the server hardware to create virtual pools of resources that canbe consumed as a service. You can then organize the pool of network capacity in logical networks thatare directly attached to specific applications.

Geneve is a tunneling mechanism which provides extensibility while still using the offload capabilities ofNICs for performance improvement.

Geneve works by creating Layer 2 logical networks that are encapsulated in UDP packets. A Segment IDin every frame identifies the Geneve logical networks without the need for VLAN tags. As a result, manyisolated Layer 2 networks can coexist on a common Layer 3 infrastructure using the same VLAN ID.

In the vSphere architecture, the encapsulation is performed between the virtual NIC of the guest VM andthe logical port on the virtual switch, making the Geneve overlay transparent to both the guest virtualmachines and the underlying Layer 3 network. The Tier-0 Gateway performs gateway services betweenoverlay and non-overlay hosts, for example, a physical server or the Internet router. The NSX-T Edgevirtual machine translates overlay segment IDs to VLAN IDs, so that non-overlay hosts can communicatewith virtual machines on an overlay network.

The edge cluster hosts all NSX-T Edge virtual machine instances that connect to the corporate networkfor secure and centralized network administration.

Table 3-19. Geneve Overlay Design Decisions

Decision ID Design Decision Design Justification Design Implication

NSXT-VI-NET-003 Use NSX-T to introduceoverlay networks forworkloads.

Simplifies the networkconfiguration by usingcentralized virtual networkmanagement.

n Requires additionalcompute and storageresources to deploy NSX-Tcomponents.

n Might require more trainingin NSX-T.

NSXT-VI-NET-004 To provide virtualized networkcapabilities to workloads, useoverlay networks with NSX-TEdge virtual machines anddistributed routing.

Creates isolated, multi-tenantbroadcast domains acrossdata center fabrics to deployelastic, logical networks thatspan physical networkboundaries.

Requires configuring transportnetworks with an MTU size ofat least 1600 bytes.

vMotion TCP/IP Stack for NSX-T Workload Domains with Multiple AvailabilityZonesUse the vMotion TCP/IP stack to isolate traffic for vSphere vMotion and to assign a dedicated defaultgateway for vSphere vMotion traffic.

By using a separate TCP/IP stack, you can manage vSphere vMotion and cold migration traffic accordingto the topology of the network, and as required for your organization.

n Route the traffic for the migration of virtual machines by using a default gateway that is different fromthe gateway assigned to the default stack on the ESXi host.

Architecture and Design for VMware NSX-T for Workload Domains with Multiple Availability Zones

VMware, Inc. 46

Page 47: Architecture and Design for VMware NSX-T for …...Architecture and Design for VMware NSX-T for Workload Domains with Multiple Availability Zones 03 SEP 2019 VMware Validated Design

n Assign a separate set of buffers and sockets.

n Avoid routing table conflicts that might otherwise appear when many features are using a commonTCP/IP stack.

n Isolate traffic to improve security.

Table 3-20. vMotion TCP/IP Stack Design Decision

Decision ID Design Decision Design Justification Design Implication

NSXT-VI-NET-005 Use the vMotion TCP/IP stackfor vSphere vMotion traffic.

By using the vMotion TCP/IPstack, vSphere vMotion trafficcan be assigned a defaultgateway on its own subnetand can go over Layer 3networks.

The vMotion TCP/IP stack isnot available in the VMkerneladapter creation wizard ofvSphere Distributed Switch.You must create the VMkerneladapter directly on the ESXihost.

NSX Design for NSX-T Workload Domains with MultipleAvailability ZonesThis design implements software-defined networking by using VMware NSX-T. By using NSX-T,virtualization delivers for networking what it has already delivered for compute and storage.

In much the same way that server virtualization programmatically creates, takes snapshots of, deletes,and restores software-based virtual machines (VMs), NSX network virtualization programmaticallycreates, takes snapshots of, deletes, and restores software-based virtual networks. As a result, you followa simplified operational model for the underlying physical network.

NSX-T is a nondisruptive solution. You can deploy it on any IP network, including existing traditionalnetworking models and next-generation fabric architectures, regardless of the vendor.

When administrators provision workloads, network management is a time-consuming task. You spendmost time configuring individual components in the physical infrastructure and verifying that networkchanges do not affect other devices that are using the same physical network infrastructure.

The need to pre-provision and configure networks is a constraint to cloud deployments where speed,agility, and flexibility are critical requirements. Pre-provisioned physical networks enable fast creation ofvirtual networks and faster deployment times of workloads using the virtual network. If the physicalnetwork that you need is already available on the ESXi host to run a workload, pre-provisioning physicalnetworks works well. However, if the network is not available on an ESXi host, you must find an ESXi hostwith the available network and allocate capacity to run workloads in your environment.

Decouple virtual networks from their physical counterparts. In the virtualized environment, you mustrecreate all physical networking attributes that are required by the workloads. Because networkvirtualization supports the creation of virtual networks without modification of the physical networkinfrastructure, you can provision the workload networks faster.

n NSX-T Design for NSX-T Workload Domains with Multiple Availability Zones

NSX-T components are not dedicated to a specific vCenter Server or vSphere construct. You canshare them across different vSphere environments.

Architecture and Design for VMware NSX-T for Workload Domains with Multiple Availability Zones

VMware, Inc. 47

Page 48: Architecture and Design for VMware NSX-T for …...Architecture and Design for VMware NSX-T for Workload Domains with Multiple Availability Zones 03 SEP 2019 VMware Validated Design

n NSX-T Components for NSX-T Workload Domains with Multiple Availability Zones

The following sections describe the components in the solution and how they are relevant to thenetwork virtualization design.

n NSX-T Network Requirements and Sizing for NSX-T Workload Domains with Multiple AvailabilityZones

NSX-T requirements impact both physical and virtual networks.

n NSX-T Network Virtualization Conceptual Design for NSX-T Workload Domains with MultipleAvailability Zones

This conceptual design for NSX-T provides the network virtualization design of the logicalcomponents that handle the data to and from tenant workloads in the environment.

n Cluster Design for NSX-T Workload Domains with Multiple Availability Zones

The NSX-T design uses management, and shared edge and compute clusters. You can add morecompute clusters for scale-out, or different workload types or SLAs.

n Replication Mode of Segments for NSX-T Workload Domains with Multiple Availability Zones

The control plane decouples NSX-T from the physical network, and handles the broadcast, unknownunicast, and multicast (BUM) traffic in the segments (logical switches).

n Transport Zone Design for NSX-T Workload Domains with Multiple Availability Zones

Transport zones determine which hosts can participate in the use of a particular network. A transportzone identifies the type of traffic, VLAN or overlay, and the N-VDS name. You can configure one ormore transport zones. A transport zone does not represent a security boundary.

n Network I/O Control Design for NSX-T Workload Domains with Multiple Availability Zones

When a Network I/O Control profile is attached to an N-VDS, during contention the switch allocatesavailable bandwidth according to the configured shares, limit, and reservation for each vSpheretraffic type.

n Transport Node and Uplink Policy Design for NSX-T Workload Domains with Multiple AvailabilityZones

A transport node can participate in an NSX-T overlay or NSX-T VLAN network.

n Routing Design by Using NSX-T for NSX-T Workload Domains with Multiple Availability Zones

The routing design considers different levels of routing in the environment, such as number and typeof NSX-T routers, dynamic routing protocol, and so on. At each level, you apply a set of principlesfor designing a scalable routing solution.

n Virtual Network Design Example Using NSX-T for NSX-T Workload Domains with MultipleAvailability Zones

Design a setup of virtual networks where you determine the connection of virtual machines toSegments and the routing between the Tier-1 Gateway and Tier-0 Gateway, and then between theTier-0 Gateway and the physical network.

Architecture and Design for VMware NSX-T for Workload Domains with Multiple Availability Zones

VMware, Inc. 48

Page 49: Architecture and Design for VMware NSX-T for …...Architecture and Design for VMware NSX-T for Workload Domains with Multiple Availability Zones 03 SEP 2019 VMware Validated Design

n Monitoring NSX-T for NSX-T Workload Domains with Multiple Availability Zones

Monitor the operation of NSX-T for identifying failures in the network setup by using vRealize LogInsight and vRealize Operations Manager.

n Use of SSL Certificates in NSX-T for NSX-T Workload Domains with Multiple Availability Zones

By default, NSX-T Manager uses a self-signed Secure Sockets Layer (SSL) certificate. Thiscertificate is not trusted by end-user devices or Web browsers.

NSX-T Design for NSX-T Workload Domains with Multiple Availability ZonesNSX-T components are not dedicated to a specific vCenter Server or vSphere construct. You can sharethem across different vSphere environments.

NSX-T, while not dedicated to a vCenter Server, supports only single-region deployments in the currentrelease. This design is focused on compute clusters in a single region.

Table 3-21. NSX-T Design Decisions

Design ID Design Decision Design Justification Design Implications

NSXT-VI-SDN-001 Deploy three NSX-T Managerappliances to configure andmanage all NSX-T basedcompute clusters in a singleregion.

Software-defined networking(SDN) capabilities offered byNSX, such as load balancingand firewalls, are required tosupport the requiredfunctionality in the computeand edge layers.

As of NSX-T 2.4, the theNSX-T Manager also servesthe role of the NSX-TControllers. You deploy threenodes in the cluster foravailability of services.

You must install and configureNSX-T Manager in a highlyavailable management cluster.

Management cluster requiresfour physical ESXi hosts forredunancy.

NSXT-VI-SDN-002 In the management cluster,add the NSX-T Manager tothe NSX for vSphereDistributed Firewall exclusionlist.

Ensures that themanagement plane is stillavailable if a misconfigurationof the NSX for vSphereDistributed Firewall occurs.

None.

NSX-T Components for NSX-T Workload Domains with Multiple AvailabilityZonesThe following sections describe the components in the solution and how they are relevant to the networkvirtualization design.

NSX-T Manager

NSX-T Manager provides the graphical user interface (GUI) and the RESTful API for creating,configuring, and monitoring NSX-T components, such as segments and gateways.

Architecture and Design for VMware NSX-T for Workload Domains with Multiple Availability Zones

VMware, Inc. 49

Page 50: Architecture and Design for VMware NSX-T for …...Architecture and Design for VMware NSX-T for Workload Domains with Multiple Availability Zones 03 SEP 2019 VMware Validated Design

NSX-T Manager implements the management and control plane for the NSX-T infrastructure. NSX-TManager provides an aggregated system view and is the centralized network management component ofNSX-T. It provides a method for monitoring and troubleshooting workloads attached to virtual networks. Itprovides configuration and orchestration of the following services:

n Logical networking components, such as logical switching and routing

n Networking and edge services

n Security services and distributed firewall

NSX-T Manager also provides a RESTful API endpoint to automate consumption. Because of thisarchitecture, you can automate all configuration and monitoring operations using any cloud managementplatform, security vendor platform, or automation framework.

The NSX-T Management Plane Agent (MPA) is an NSX-T Manager component that is available on eachESXi host. The MPA is in charge of persisting the desired state of the system and for communicating non-flow-controlling (NFC) messages such as configuration, statistics, status, and real-time data betweentransport nodes and the management plane.

NSX-T Manager also contains the NSX-T Controller component. NSX-T Controllers control the virtualnetworks and overlay transport tunnels. The controllers are responsible for the programmatic deploymentof virtual networks across the entire NSX-T architecture.

The Central Control Plane (CCP) is logically separated from all data plane traffic, that is, a failure in thecontrol plane does not affect existing data plane operations. The controller provides configuration to otherNSX-T Controller components such as the segments, gateways, and edge virtual machine configuration.

Table 3-22. NSX-T Manager Design Decisions

Decision ID Design Decision Design Justification Design Implications

NSXT-VI-SDN-003 Deploy a three node NSX-TManager cluster using thelarge-size appliance.

The large-size appliancesupports greater than 64ESXi hosts. The small-sizeappliance is for proof ofconcept and the medium sizeonly supports up to 64 ESXihosts.

The large size requires moreresources in the managementcluster.

NSXT-VI-SDN-004 Create a virtual IP (VIP) forthe NSX-T Manager cluster.

Provides HA for the NSX-TManager UI and API.

The VIP provides HA only, itdoes not load balance requestsacross the manager cluster.

NSXT-VI-SDN-005 n Grant administratorsaccess to both the NSX-TManager UI and itsRESTful API endpoint.

n Restrict end-user accessto the RESTful APIendpoint configured forend-user provisioning,such as vRealizeAutomation or VMwareEnterprise PKS.

Ensures that tenants or non-provider staff cannot modifyinfrastructure components.

End-users typically interactonly indirectly with NSX-Tfrom their provisioning portal.Administrators interact withNSX-T using its UI and API.

End users have access only toend-point components.

Architecture and Design for VMware NSX-T for Workload Domains with Multiple Availability Zones

VMware, Inc. 50

Page 51: Architecture and Design for VMware NSX-T for …...Architecture and Design for VMware NSX-T for Workload Domains with Multiple Availability Zones 03 SEP 2019 VMware Validated Design

NSX-T Virtual Distributed Switch

An NSX-T Virtual Distributed Switch (N-VDS) runs on ESXi hosts and provides physical traffic forwarding.It transparently provides the underlying forwarding service that each segment relies on. To implementnetwork virtualization, a network controller must configure the ESXi host virtual switch with network flowtables that form the logical broadcast domains the tenant administrators define when they create andconfigure segments.

NSX-T implements each logical broadcast domain by tunneling VM-to-VM traffic and VM-to-gatewaytraffic using the Geneve tunnel encapsulation mechanism. The network controller has a global view of thedata center and ensures that the ESXi host virtual switch flow tables are updated as VMs are created,moved, or removed.

Table 3-23. NSX-T N-VDS Design Decision

Decision ID Design Decision Design Justification Design Implications

NSXT-VI-SDN-006 Deploy an N-VDS instance toeach ESXi host in the sharededge and compute cluster.

ESXi hosts in the sharededge and compute clusterprovide tunnel endpoints forGeneve overlayencapsulation.

None.

Logical Switching

NSX-T Segments create logically abstracted segments to which you can connect tenant workloads. Asingle Segment is mapped to a unique Geneve segment that is distributed across the ESXi hosts in atransport zone. The Segment supports line-rate switching in the ESXi host without the constraints ofVLAN sprawl or spanning tree issues.

Table 3-24. NSX-T Logical Switching Design Decision

Decision ID Design Decision Design Justification Design Implications

NSXT-VI-SDN-007 Deploy all workloads on NSX-T Segments (logicalswitches).

To take advantage of featuressuch as distributed routing,tenant workloads must beconnected to NSX-TSegments.

You must perform all networkmonitoring in the NSX-TManager UI, vRealize LogInsight, vRealize OperationsManger, or vRealize NetworkInsight.

Gateways (Logical Routers)

NSX-T Gateways provide North-South connectivity so that workloads can access external networks, andEast-West connectivity between different logical networks.

A Logical Router is a configured partition of a traditional network hardware router. It replicates thefunctionality of the hardware, creating multiple routing domains in a single router. Logical routers performa subset of the tasks that are handled by the physical router, and each can contain multiple routinginstances and routing tables. Using logical routers can be an effective way to maximize router use,because a set of logical routers within a single physical router can perform the operations previouslyperformed by several pieces of equipment.

n Distributed router (DR)

Architecture and Design for VMware NSX-T for Workload Domains with Multiple Availability Zones

VMware, Inc. 51

Page 52: Architecture and Design for VMware NSX-T for …...Architecture and Design for VMware NSX-T for Workload Domains with Multiple Availability Zones 03 SEP 2019 VMware Validated Design

A DR spans ESXi hosts whose virtual machines are connected to this Gateway, and edge nodes theGateway is bound to. Functionally, the DR is responsible for one-hop distributed routing betweensegments and Gateways connected to this Gateway.

n One or more (optional) service routers (SR).

An SR is responsible for delivering services that are not currently implemented in a distributedfashion, such as stateful NAT.

A Gateway always has a DR. A Gateway has SRs when it is a Tier-0 Gateway, or when it is a Tier-1Gateway and has services configured such as NAT or DHCP.

Tunnel Endpoint

Tunnel endpoints enable ESXi hosts to participate in an NSX-T overlay. The NSX-T overlay deploys aLayer 2 network on top of an existing Layer 3 network fabric by encapsulating frames inside packets andtransferring the packets over an underlying transport network. The underlying transport network can beanother Layer 2 networks or it can cross Layer 3 boundaries. The Tunnel Endpoint (TEP) is theconnection point at which the encapsulation and decapsulation take place.

NSX-T Edges

NSX-T Edges provide routing services and connectivity to networks that are external to the NSX-Tdeployment. You use an NSX-T Edge for establishing external connectivity from the NSX-T domain byusing a Tier-0 Gateway using BGP or static routing. Additionally, you deploy an NSX-T Edge to supportnetwork address translation (NAT) services at either the Tier-0 or Tier-1 Gateway.

The NSX-T Edge connects isolated, stub networks to shared uplink networks by providing commongateway services such as NAT, and dynamic routing.

Logical Firewall

NSX-T handles traffic in and out the network according to firewall rules.

A logical firewall offers multiple sets of configurable Layer 3 and Layer 2 rules. Layer 2 firewall rules areprocessed before Layer 3 rules. You can configure an exclusion list to exclude segments, logical ports, orgroups from firewall enforcement.

The default rule, that is at the bottom of the rule table, is a catchall rule. The logical firewall enforces thedefault rule on packets that do not match other rules. After the host preparation operation, the default ruleis set to the allow action. Change this default rule to a block action and apply access control through apositive control model, that is, only traffic defined in a firewall rule can flow on the network.

Logical Load Balancer

The NSX-T logical load balancer offers high-availability service for applications and distributes thenetwork traffic load among multiple servers.

The load balancer accepts TCP, UDP, HTTP, or HTTPS requests on the virtual IP address anddetermines which pool server to use.

Logical load balancer is supported only on the Tier-1 Gateway.

Architecture and Design for VMware NSX-T for Workload Domains with Multiple Availability Zones

VMware, Inc. 52

Page 53: Architecture and Design for VMware NSX-T for …...Architecture and Design for VMware NSX-T for Workload Domains with Multiple Availability Zones 03 SEP 2019 VMware Validated Design

NSX-T Network Requirements and Sizing for NSX-T Workload Domains withMultiple Availability ZonesNSX-T requirements impact both physical and virtual networks.

Physical Network Requirements

Physical requirements determine the MTU size for networks that carry overlay traffic, dynamic routingsupport, time synchronization through an NTP server, and forward and reverse DNS resolution.

Requirement Comments

Provide an MTU size of 1600 or greater on any network thatcarries Geneve overlay traffic.

Geneve packets cannot be fragmented. The MTU size must belarge enough to support extra encapsulation overhead.

This design uses an MTU size of 9000 for Geneve traffic. SeeTable 3-4. Jumbo Frames Design Decisions.

Enable dynamic routing support on the upstream Layer 3devices.

You use BGP on the upstream Layer 3 devices to establishrouting adjacency with the Tier-0 SRs.

Provide an NTP server. The NSX-T Manager requires NTP settings that synchronize itwith the rest of the environment.

Establish forward and reverse DNS resolution for allmanagement VMs.

Enables administrators to access the NSX-T envrionement viaFQDN as opposed to memorizing IP addresses.

NSX-T Component Specifications

When you size the resources for NSX-T components, consider the compute and storage requirements foreach component, and the number of nodes per component type.

Size of NSX Edge services gateways might be different according to tenant requirements. Consider alloptions in such a case.

Table 3-25. Resource Specification of the NSX-T Components

Virtual Machine vCPU Memory (GB) Storage (GB)Quantity per NSX-TDeployment

NSX-T Manager 12 (Large) 48 (Large) 200 (Large) 3

NSX-T Edge virtualmachine

2 (Small, PoC only) 4 (Small, PoC only) 200 (Small, PoC only) Numbers are differentaccording to the usecase. At least two edgedevices are required toenable ECMP routing.

4 (Medium) 8 (Medium) 200 (Medium)

8 (Large) 32 (Large) 200 (Large)

Table 3-26. Design Decisions on Sizing the NSX-T Edge Virtual Machines

Decision ID Design Decision Design Justification Design Implications

NSXT-VI-SDN-008 Use large-size NSX-T Edgevirtual machines.

The large-size applianceprovides the requiredperformance characteristics ifa failure occurs.

Virtual Edges providesimplied lifecyclemanagement.

Large size Edges consumemore CPU and Memoryresources.

Architecture and Design for VMware NSX-T for Workload Domains with Multiple Availability Zones

VMware, Inc. 53

Page 54: Architecture and Design for VMware NSX-T for …...Architecture and Design for VMware NSX-T for Workload Domains with Multiple Availability Zones 03 SEP 2019 VMware Validated Design

NSX-T Network Virtualization Conceptual Design for NSX-T WorkloadDomains with Multiple Availability ZonesThis conceptual design for NSX-T provides the network virtualization design of the logical componentsthat handle the data to and from tenant workloads in the environment.

The network virtualization conceptual design includes a perimeter firewall, a provider logical router, andthe NSX-T Gateway. It also considers the external network, internal workload networks, and themanagement network.

Figure 3-7. NSX-T Conceptual Overview

VM VMVM VM VMVM

Internet MPLS

MgmtNetwork

External Network

Perimeter Firewall

Upstream Layer 3Devices

NSX-Т DistributedRouter (DR)

Internal Tenant Networks (Segments)

vNIC-Level Distributed Firewall

NSX-T Service Router(SR)

Architecture and Design for VMware NSX-T for Workload Domains with Multiple Availability Zones

VMware, Inc. 54

Page 55: Architecture and Design for VMware NSX-T for …...Architecture and Design for VMware NSX-T for Workload Domains with Multiple Availability Zones 03 SEP 2019 VMware Validated Design

The conceptual design has the following components.

External Networks Connectivity to and from external networks is through the perimeter firewall.

Perimeter Firewall The firewall exists at the perimeter of the data center to filter Internet traffic.

Upstream Layer 3Devices

The upstream Layer 3 devices are behind the perimeter firewall and handleNorth-South traffic that is entering and leaving the NSX-T environment. Inmost cases, this layer consists of a pair of top of rack switches orredundant upstream Layer 3 devices such as core routers.

NSX-T Service Router(SR)

The SR component of the NSX-T Tier-0 Gateway is responsible forestablishing eBGP peering with the Upstream Layer 3 devices and enablingNorth-South routing.

NSX-T DistributedRouter (DR)

The DR component of the NSX-T Gateway is responsible for East-Westrouting.

Management Network The management network is a VLAN-backed network that supports allmanagement components such as NSX-T Manager and NSX-T Controllers.

Internal TenantNetworks

Internal tenant networks are NSX-T Segments and provide connectivity forthe tenant workloads. Workloads are directly connected to these networks.Internal tenant networks are then connected to a DR.

Cluster Design for NSX-T Workload Domains with Multiple Availability ZonesThe NSX-T design uses management, and shared edge and compute clusters. You can add morecompute clusters for scale-out, or different workload types or SLAs.

The logical NSX-T design considers the vSphere clusters and defines the place where each NSXcomponent runs.

Architecture and Design for VMware NSX-T for Workload Domains with Multiple Availability Zones

VMware, Inc. 55

Page 56: Architecture and Design for VMware NSX-T for …...Architecture and Design for VMware NSX-T for Workload Domains with Multiple Availability Zones 03 SEP 2019 VMware Validated Design

Figure 3-8. NSX-T Cluster Design

APP

OSAPP

OS

APP

OS

APP

OS

APP

OS

APP

OS

APP

OS

APP

OSAPP

OSAPP

OS

APP

OSAPP

OS

APP

OSAPP

OS

APP

OSAPP

OS

APP

OS

APP

OSAPP

OS

APP

OSAPP

OSAPP

OS

APP

OSAPP

OS

Virtual InfrastructureManagement

NSXControllers

(Mgmt)

OtherManagementApplications

NSXManager(Mgmt)

NSX-TManager Cluster

(Compute)

NSX-T Edges(Compute)

ESXi

TransportNodes

ESXi ESXi ESXi

SDDCPayload

Virtual Infrastructure Compute Edge

NSX-T Transport Zones (Compute)

N-VDS (Compute) vDS (Mgmt)

NSX-V Transport Zones (Mgmt)

Stretched Shared Edge and Compute Cluster

Stretched Management Cluster

Managed by: Compute vCenter Server

Managed by:Management vCenter Server

Network: External(Internet/Corporate)Network: Internal SDDC

vCenterServer(Mgmt)

vCenterServer

(Compute)

ESXiESXi

TransportNodes

ESXi

TransportNodes

ESXi

TransportNodes

Availability Zone 1 - Management and Shared Edge and Compute Clusters

ESXi

TransportNodes

ESXi ESXi ESXiESXi

ESXi

TransportNodes

ESXi

TransportNodes

ESXi

TransportNodes

N-VDS (Compute) vDS (Mgmt)

NSX-T Transport Zones (Compute) NSX-V Transport Zones (Mgmt)

Availability Zone 2 (Secondary) - Management and Shared Edge and Compute Clusters

Virtual InfrastructureManagement

NSX-TSecondary Edge(Mgmt)

OtherManagementApplications

NSX-T Edges(Compute)

SDDCPayload

Virtual Infrastructure Compute Edge

Architecture and Design for VMware NSX-T for Workload Domains with Multiple Availability Zones

VMware, Inc. 56

Page 57: Architecture and Design for VMware NSX-T for …...Architecture and Design for VMware NSX-T for Workload Domains with Multiple Availability Zones 03 SEP 2019 VMware Validated Design

Management Cluster

The management cluster contains all components for managing the SDDC. This cluster is a corecomponent of the VMware Validated Design for Software-Defined Data Center. For information about themanagement cluster design, see the Architecture and Design documentation in VMware Validated Designfor Software-Defined Data Center.

NSX-T Edge Node Cluster

The NSX-T Edge cluster is a logical grouping of NSX-T Edge virtual machines. These NSX-T Edge virtualmachines run in the vSphere shared edge and compute cluster and provide North-South routing andnetwork services for workloads in the compute clusters.

Shared Edge and Compute Cluster

In the shared edge and compute cluster, ESXi hosts are prepared for NSX-T. As a result, they can beconfigured as transport nodes and can participate in the overlay network. All tenant workloads, and NSX-T Edge virtual machines run in this cluster.

Table 3-27. Cluster Design Decisions

Decision ID Design Decision Design Justification Design Implications

NSXT-VI-SDN-009 For virtual infrastructureworkload domains, do notdedicate an edge cluster invSphere.

Simplifies configuration andminimizes the number ofESXi hosts required for initialdeployment.

The NSX-T Edge virtualmachines are deployed in theshared edge and computecluster.

Because of the shared natureof the cluster, to avoid animpact on networkperformance, you must scaleout the cluster as you addtenant workloads.

NSXT-VI-SDN-010 Deploy at least four large-size NSX-T Edge virtualmachines, two in eachavailability zone, in theshared edge and computecluster.

Creates the NSX-T Edgecluster, and meets availabilityand scale requirements.

When additional Edge VM'sare added, the Resource PoolMemory Reservation must beadjusted.

NSXT-VI-SDN-011 Apply VM-VM anti-affinityrules in vSphere DistributedResource Scheduler(vSphere DRS) to the NSX-TManager appliances.

Keeps the NSX-T Managerappliances running ondifferent ESXi hosts for highavailability.

Requires at least four physicalhosts to guarantee the threeNSX-T Manager appliancescontinue to run if an ESXi hostfailure occurs.

Additional configuration isrequired to set up anti-affinityrules.

Architecture and Design for VMware NSX-T for Workload Domains with Multiple Availability Zones

VMware, Inc. 57

Page 58: Architecture and Design for VMware NSX-T for …...Architecture and Design for VMware NSX-T for Workload Domains with Multiple Availability Zones 03 SEP 2019 VMware Validated Design

Table 3-27. Cluster Design Decisions (continued)

Decision ID Design Decision Design Justification Design Implications

NSXT-VI-SDN-012 Create two VM-VM anti-affinity rules for vSphereDRS, one per availabilityzone, for the edge virtualmachines in each availabilityzone.

Keeps the NSX-T Edgevirtual machines in anavailability zone running ondifferent ESXi hosts for highavailability.

You must perform additionalconfiguration to set up the anti-affinity rules.

NSXT-VI-SDN-013 Create a virtual machnegroup that contains the edgeand tenant virtual machinesin Availability Zone 1.

Ensures that virtual machinesare located only in theassigned availability zone.

You must add VMs to theallocated group manually toensure they are not powered-on in or migrated to the wrongavailability zone.

NSXT-VI-SDN-014 Create a VM group thatcontains the edge virtualmachines and tenantworkloads in Availability Zone2.

Ensures that virtual machinesare located only in theassigned availability zone.

You must add VMs to theallocated group manually toensure they are not powered-on in or migrated to the wrongavailability zone.

NSXT-VI-SDN-015 Create a host group thatcontains the ESXi hosts inAvailability Zone 1.

Makes it easier to managewhich virtual machinesshould run in whichavailability zone.

You must create and maintainVM/Host DRS groups.

NSXT-VI-SDN-016 Create a host group thatcontains the ESXi hosts inAvailability Zone 2.

Makes it easier to managewhich virtual machinesshould run in whichavailability zone.

You must create and maintainVM/Host DRS groups.

NSXT-VI-SDN-017 Create a VM/Host DRS rulethat specifies that VM's in theVM Availability Zone 1 groupshould run on ESXi hosts inthe Availability Zone 1 group.

Ensures VM's that should runin Availability Zone 1 do notget migrated to AvailabilityZone 2.

The should rule allows theVM's to failover to AvailabilityZone 2 in the case of afailure.

You must create VM to HostDRS rules.

NSXT-VI-SDN-018 Create a VM/Host DRS rulethat specifies that VM's in theVM Availability Zone 2 groupshould run on ESXi hosts inthe Availability Zone 2 group.

Ensures VM's that should runin Availability Zone 2 do notget migrated to AvailabilityZone 1.

The should rule allows theVM's to failover to AvailabilityZone 2 in the case of afailure.

You must create VM to HostDRS rules.

High Availability of NSX-T Components

The NSX-T Managers run on the management cluster. vSphere HA protects the NSX-T Managers byrestarting the NSX-T Manager virtual machine on a different ESXi host if a primary ESXi host failureoccurs.

Architecture and Design for VMware NSX-T for Workload Domains with Multiple Availability Zones

VMware, Inc. 58

Page 59: Architecture and Design for VMware NSX-T for …...Architecture and Design for VMware NSX-T for Workload Domains with Multiple Availability Zones 03 SEP 2019 VMware Validated Design

The data plane remains active during outages in the management and control planes although theprovisioning and modification of virtual networks is impaired until those planes become available again.

The NSX-T Edge virtual machines are deployed on the shared edge and compute cluster. vSphere DRSanti-affinity rules prevent NSX-T Edge virtual machines that belong to the same NSX-T Edge cluster fromrunning on the same ESXi host.

NSX-T SRs for North-South routing are configured in equal-cost multi-path (ECMP) mode that supportsroute failover in seconds.

Replication Mode of Segments for NSX-T Workload Domains with MultipleAvailability ZonesThe control plane decouples NSX-T from the physical network, and handles the broadcast, unknownunicast, and multicast (BUM) traffic in the segments (logical switches).

The following options are available for BUM replication on segments.

Table 3-28. BUM Replication Mode of NSX-T Segments

BUM Replication Mode Description

Hierarchical Two-Tier In this mode, the ESXi host transport nodes are groupedaccording to their TEP IP subnet. One ESXi host in each subnetis responsible for replication to a ESXi host in another subnet.The receiving ESXi host replicates the traffic to the ESXi hosts inits local subnet.

The source ESXi host transport node knows about the groupsbased on information it has received from the NSX-T controlcluster. The system can select an arbitrary ESXi host transportnode as the mediator for the source subnet if the remotemediator ESXi host node is available.

Head-End In this mode, the ESXi host transport node at the origin of theframe to be flooded on a segment sends a copy to every otherESXi host transport node that is connected to this segment.

Table 3-29. Design Decisions on Segment Replication Mode

Decision ID Design Decision Design Justification Design Implications

NSXT-VI-SDN-019 Use hierarchical two-tierreplication on all segments.

Hierarchical two-tierreplication is more efficient byreducing the number of ESXihosts the source ESXi hostmust replicate traffic to.

None.

Transport Zone Design for NSX-T Workload Domains with MultipleAvailability ZonesTransport zones determine which hosts can participate in the use of a particular network. A transportzone identifies the type of traffic, VLAN or overlay, and the N-VDS name. You can configure one or moretransport zones. A transport zone does not represent a security boundary.

Architecture and Design for VMware NSX-T for Workload Domains with Multiple Availability Zones

VMware, Inc. 59

Page 60: Architecture and Design for VMware NSX-T for …...Architecture and Design for VMware NSX-T for Workload Domains with Multiple Availability Zones 03 SEP 2019 VMware Validated Design

Table 3-30. Transport Zones Design Decisions

Decision ID Design Decision Design Justification Design Implications

NSXT-VI-SDN-020 Create a single transportzone for all overlay trafficacross all workload domains.

Ensures all Segments areavailable to all ESXi hostsand edge virtual machinesconfigured as TransportNodes.

None.

NSXT-VI-SDN-021 Create a VLAN transportzone for ESXi host VMkernelports.

Enables the migration of ESXihost VMkernel ports to the N-VDS.

The N-VDS name must matchthe N-VDS name in the overlaytransport zone.

NSXT-VI-SDN-022 Create two transport zonesfor edge virtual machineuplinks.

Enables the edge virtualmachines to use equal-costmulti-path routing (ECMP).

You must specify a VLANrange, that is use VLANtrunking, on the segment usedas the uplinks.

Network I/O Control Design for NSX-T Workload Domains with MultipleAvailability ZonesWhen a Network I/O Control profile is attached to an N-VDS, during contention the switch allocatesavailable bandwidth according to the configured shares, limit, and reservation for each vSphere traffictype.

How Network I/O Control Works

Network I/O Control enforces the share value specified for the different traffic types only when there isnetwork contention. When contention occurs, Network I/O Control applies the share values set to eachtraffic type. As a result, less important traffic, as defined by the share percentage, is throttled, grantingaccess to more network resources to more important traffic types.

Network I/O Control also supports the reservation of bandwidth for system traffic according to the overallpercentage of available bandwidth.

Network I/O Control Heuristics

The following heuristics can help with design decisions.

Shares vs. Limits When you use bandwidth allocation, consider using shares instead of limits.Limits impose hard limits on the amount of bandwidth used by a traffic floweven when network bandwidth is available.

Limits on NetworkResource Pools

Consider imposing limits on a resource pool. For example, set a limit onvSphere vMotion traffic to avoid oversubscription at the physical networklevel when multiple vSphere vMotion data transfers are initiated on differentESXi hosts at the same time. By limiting the available bandwidth forvSphere vMotion at the ESXi host level, you can prevent performancedegradation for other traffic.

Architecture and Design for VMware NSX-T for Workload Domains with Multiple Availability Zones

VMware, Inc. 60

Page 61: Architecture and Design for VMware NSX-T for …...Architecture and Design for VMware NSX-T for Workload Domains with Multiple Availability Zones 03 SEP 2019 VMware Validated Design

Network I/O Control Design Decisions

Based on the heuristics, this design has the following decisions.

Table 3-31. Network I/O Control Design Decisions

Decision ID Design Decision Design Justification Design Implication

NSXT-VI-SDN-023 Create and attach a NetworkI/O Control Policy on all N-DVS switches.

Increases resiliency andperformance of the network.

If configured incorrectly,Network I/O Control mightimpact network performancefor critical traffic types.

NSXT-VI-SDN-024 Set the share value forvSphere vMotion traffic toLow (25).

During times of networkcontention, vSphere vMotiontraffic is not as important asvirtual machine or storagetraffic.

During times of networkcontention, vMotion takeslonger than usual to complete.

NSXT-VI-SDN-025 Set the share value forvSphere Replication traffic toLow (25).

During times of networkcontention, vSphereReplication traffic is not asimportant as virtual machineor storage traffic.

During times of networkcontention, vSphereReplication takes longer andmight violate the defined SLA.

NSXT-VI-SDN-026 Set the share value for vSANtraffic to High (100).

During times of networkcontention, vSAN trafficneeds a guaranteedbandwidth to support virtualmachine performance.

None.

NSXT-VI-SDN-027 Set the share value formanagement traffic to Normal(50).

By keeping the default settingof Normal, managementtraffic is prioritized higher thanvSphere vMotion andvSphere Replication but lowerthan vSAN traffic.Management traffic isimportant because it ensuresthat the hosts can still bemanaged during times ofnetwork contention.

None.

NSXT-VI-SDN-028 Set the share value for NFStraffic to Low (25).

Because NFS is used forsecondary storage, such asbackups and vRealize LogInsight archives, its priority islower than the priority of thevSAN traffic.

During times of networkcontention, backups are slowerthan usual.

NSXT-VI-SDN-029 Set the share value forbackup traffic to Low (25).

During times of networkcontention, the primaryfunctions of the SDDC mustcontinue to have access tonetwork resources withpriority over backup traffic.

During times of networkcontention, backups are slowerthan usual.

Architecture and Design for VMware NSX-T for Workload Domains with Multiple Availability Zones

VMware, Inc. 61

Page 62: Architecture and Design for VMware NSX-T for …...Architecture and Design for VMware NSX-T for Workload Domains with Multiple Availability Zones 03 SEP 2019 VMware Validated Design

Table 3-31. Network I/O Control Design Decisions (continued)

Decision ID Design Decision Design Justification Design Implication

NSXT-VI-SDN-030 Set the share value for virtualmachines to High (100).

Virtual machines are the mostimportant asset in the SDDC.Leaving the default setting ofHigh ensures that they alwayshave access to the networkresources they need.

None.

NSXT-VI-SDN-031 Set the share value forvSphere Fault Tolerance toLow (25).

This design does not usevSphere Fault Tolerance.Fault tolerance traffic can beset the lowest priority.

None.

NSXT-VI-SDN-032 Set the share value for iSCSItraffic to Low (25).

This design does not useiSCSI. iSCSI traffic can be setthe lowest priority.

None.

Transport Node and Uplink Policy Design for NSX-T Workload Domains withMultiple Availability ZonesA transport node can participate in an NSX-T overlay or NSX-T VLAN network.

Several types of transport nodes are available in NSX-T.

ESXi Host TransportNodes

ESXi host transport nodes are ESXi hosts prepared and configured forNSX-T. N-VDS provides network services to the virtual machines runningon these ESXi hosts.

Edge Nodes NSX-T Edge nodes are service appliances that run network services thatcannot be distributed to the hypervisors. They are grouped in one orseveral NSX-T Edge clusters. Each cluster represents a pool of capacity.

Uplink profiles define policies for the links from ESXi hosts to NSX-T Segments or from NSX-T Edgevirtual machines to top of rack switches. By using uplink profiles, you can apply consistent configurationof capabilities for network adapters across multiple ESXi hosts or edge virtual machines. Uplink profilesare containers for the properties or capabilities for the network adapters.

Uplink profiles can use either load balance source or failover order teaming. If using load balance source,multiple uplinks can be active. If using failover order, only a single uplink can be active.

Architecture and Design for VMware NSX-T for Workload Domains with Multiple Availability Zones

VMware, Inc. 62

Page 63: Architecture and Design for VMware NSX-T for …...Architecture and Design for VMware NSX-T for Workload Domains with Multiple Availability Zones 03 SEP 2019 VMware Validated Design

Table 3-32. Design Decisions on Transport Nodes and Uplink Policy

Decision ID Design Decision Design Justification Design Implications

NSXT-VI-SDN-033 Create an uplink profile withthe load balance sourceteaming policy with two activeuplinks for ESXi hosts.

For increased resiliency andperformance, supports theconcurrent use of bothphysical NICs on the ESXihosts that are configured astransport nodes.

You can use this policy onlywith ESXi hosts. Edge virtualmachines must use the failoverorder teaming policy.

NSXT-VI-SDN-034 Create an uplink profile withthe failover order teamingpolicy with one active uplinkand no standby uplinks foredge virtual machine overlaytraffic.

Provides a profile accordingto the requirements for Edgevirtual machines. Edge virtualmachines support uplinkprofiles only with a failoverorder teaming policy.

VLAN ID is required in theuplink profile. Hence, youmust create an uplink profilefor each VLAN used by theedge virtual machines.

n You create and managemore uplink profiles.

n The VLAN ID used must bedifferent than the VLAN IDfor ESXi host overlaytraffic.

NSXT-VI-SDN-035 Create two uplink profiles perAvailability Zone with thefailover order teaming policywith one active uplink and nostandby uplinks for edgevirtual machine uplink traffic.

Enables ECMP in eachAvailability Zone because theеdge virtual machine canuplink to the physical networkover two different VLANs.

You create and manage moreuplink profiles.

NSXT-VI-SDN-036 Configure each ESXi host asa Transport Node without theuse of Transport NodeProfiles.

Enables the participation ofESXi hosts and the virtualmachines on them in NSX-Toverlay and VLAN networks.

Transport Node Profiles canonly be applied at the clusterlevel, because eachAvailability Zone is a memberof different VLAN's a TranportNode Profile can not be used.

ESXi hosts VMKernel adaptersare migrated to the N-VDS.Ensure the VLAN ID's for theVMKernel Segments arecorrect to ensure hostcommunication is not lost.

NSXT-VI-SDN-037 Add as transport nodes alledge virtual machines.

Enables the participation ofedge virtual machines in theoverlay network and thedelivery of services, such asrouting, by these machines.

None.

NSXT-VI-SDN-038 Create an NSX-T Edgecluster with the defaultBidirectional ForwardingDetection (BFD) settingscontaining the edge transportnodes.

Satisfies the availabilityrequirements by default.

Edge clusters are required tocreate services such as NAT,routing to physical networks,and load balancing.

None.

Architecture and Design for VMware NSX-T for Workload Domains with Multiple Availability Zones

VMware, Inc. 63

Page 64: Architecture and Design for VMware NSX-T for …...Architecture and Design for VMware NSX-T for Workload Domains with Multiple Availability Zones 03 SEP 2019 VMware Validated Design

Routing Design by Using NSX-T for NSX-T Workload Domains with MultipleAvailability ZonesThe routing design considers different levels of routing in the environment, such as number and type ofNSX-T routers, dynamic routing protocol, and so on. At each level, you apply a set of principles fordesigning a scalable routing solution.

Routing can be defined in the following directions: North-South and East-West.

n North-South traffic is traffic leaving or entering the NSX-T domain, for example, a virtual machine onan overlay network communicating with an end-user device on the corporate network.

n East-West traffic is traffic that remains in the NSX-T domain, for example, two virtual machines on thesame or different segments communicating with each other.

Table 3-33. Design Decisions on Routing Using NSX-T

Decision ID Design Decision Design Justification Design Implications

NSXT-VI-SDN-039 Create two VLANs perAvailability Zone to enableECMP between the Tier-0Gateway and the Layer 3device (ToR or upstreamdevice).

The ToR switches orupstream Layer 3 deviceshave an SVI on one of thetwo VLANS and each edgevirtual machine has aninterface on each VLAN.

Supports multiple equal-costroutes on the Tier-0 Gatewayand provides more resiliencyand better bandwidth use inthe network.

Extra VLANs are required.

NSXT-VI-SDN-040 Deploy an Active-ActiveTier-0 Gateway.

Supports ECMP North-Southrouting on all edge virtualmachines in the NSX-T Edgecluster.

Active-Active Tier-0 Gatewayscannot provide services suchas NAT. If you deploy a specificsolution that requires statefulservices on the Tier-0Gateway, such as VMwareEnterprise PKS, you mustdeploy a Tier-0 Gateway inActive-Standby mode.

NSXT-VI-SDN-041 Use BGP as the dynamicrouting protocol.

Enables the dynamic routingby using NSX-T. NSX-Tsupports only BGP .

In environments where BGPcannot be used, you mustconfigure and manage staticroutes.

NSXT-VI-SDN-042 Configure BGP Keep AliveTimer to 4 and Hold DownTimer to 12 between the ToRswitches and the Tier-0Gateway.

Provides a balance betweenfailure detection between theToR switches and the Tier-0Gateway and overburdeningthe ToRs with keep alivetraffic.

By using longer timers todetect if a router is notresponding, the data aboutsuch a router remains in therouting table longer. As aresult, the active routercontinues to send traffic to arouter that is down.

Architecture and Design for VMware NSX-T for Workload Domains with Multiple Availability Zones

VMware, Inc. 64

Page 65: Architecture and Design for VMware NSX-T for …...Architecture and Design for VMware NSX-T for Workload Domains with Multiple Availability Zones 03 SEP 2019 VMware Validated Design

Table 3-33. Design Decisions on Routing Using NSX-T (continued)

Decision ID Design Decision Design Justification Design Implications

NSXT-VI-SDN-043 Do not enable GracefulRestart between BGPneighbors.

Avoids loss of traffic. GracefulRestart maintains theforwarding table which in turnwill forward packets to a downneighbor even after the BGPtimers have expired causingloss of traffic.

None.

NSXT-VI-SDN-044 Create an IP Prefix List thatconsists of 'any' for thenetwork and Permit as theaction instead of using thedefault IP Prefix List.

Will be used in a Route Mapto configure AS Path Prependfor Availability Zone 2 BGPneighbors.

Requires manually creating anIP Prefix List that is identical tothe default.

NSXT-VI-SDN-045 Create a Route Map thatcontains the newly created IPPrefix and the Tier-0 Local ASadded twice as the AS PathPrepend value.

Will be used when configuringneighbor relationships withAvailability Zone 2 L3devices.

Ensures all ingress/egresstraffic goes throughAvailability Zone 1.

Requires manually creating theRoute Map.

The two edge VMs inAvailability Zone 2 will not routenorth/south traffic unlessAvailability Zone 1 edge VMslose their BGP neighbors, suchas ToR or Availability ZoneFailures.

NSXT-VI-SDN-046 Configure Availability Zone 2neighbors to use the newlycreated Route Map as In andOut filters.

Makes the path in and out ofAvailability Zone 2 lesspreferred as the AS Path islonger, which results in alltraffic going throughAvailability Zone 1.

The two edge VMs inAvailability Zone 2 will not routenorth/south traffic unlessAvailability Zone 1 edge VMslose their BGP neighbors, suchas ToR or Availability ZoneFailures.

NSXT-VI-SDN-047 Deploy a Tier-1 Gateway tothe NSX-T Edge cluster andconnect it to the Tier-0Gateway.

Creates a two-tier routingarchitecture that supportsload balancers and NAT.

Because the Tier-1 is alwaysActive/Standby, creation ofservices such as loadbalancers or NAT is possible.

A Tier-1 Gateway can only beconnected to a single Tier-0Gateway.

In scenarios where multipleTier-0 Gateways are required,you must create multiple Tier-1Gateways.

Architecture and Design for VMware NSX-T for Workload Domains with Multiple Availability Zones

VMware, Inc. 65

Page 66: Architecture and Design for VMware NSX-T for …...Architecture and Design for VMware NSX-T for Workload Domains with Multiple Availability Zones 03 SEP 2019 VMware Validated Design

Table 3-33. Design Decisions on Routing Using NSX-T (continued)

Decision ID Design Decision Design Justification Design Implications

NSXT-VI-SDN-048 Deploy a Tier-1 Gateway tothe NSX-T Edge cluster,choosing one Edge TransportNode from each AvailabilityZone and connect it to theTier-0 Gateway.

Creates a two-tier routingarchitecture that supportsload balancers and NAT.

Because the Tier-1 is alwaysActive/Standby, creation ofservices such as loadbalancers or NAT is possible.

Ensures that during anAvailability Zone outage anyservices running on theTier-1, such as a loadbalancer, will quickly failoverto the standby edge.

A Tier-1 Gateway can only beconnected to a single Tier-0Gateway.

In scenarios where multipleTier-0 Gateways are required,you must create multiple Tier-1Gateways.

NSXT-VI-SDN-049 Deploy Tier-1 Gateways withthe Non-Premptive setting.

Ensures that when the failedEdge Transport Node comesback online it doesn't moveservices back to itselfresulting in a small serviceoutage.

None.

Virtual Network Design Example Using NSX-T for NSX-T Workload Domainswith Multiple Availability ZonesDesign a setup of virtual networks where you determine the connection of virtual machines to Segmentsand the routing between the Tier-1 Gateway and Tier-0 Gateway, and then between the Tier-0 Gatewayand the physical network.

Architecture and Design for VMware NSX-T for Workload Domains with Multiple Availability Zones

VMware, Inc. 66

Page 67: Architecture and Design for VMware NSX-T for …...Architecture and Design for VMware NSX-T for Workload Domains with Multiple Availability Zones 03 SEP 2019 VMware Validated Design

Figure 3-9. Virtual Network Example

Physical Layer 3 Devices

Tier-1 to Tier-0 Connection

Legend:VLANs

Segment

ECMP

NSX-T Edge Cluster

Edge VM 1 Edge VM 2

Tier-1Gateway

Edge VM 1 Edge VM 3

Tier-0Gateway

Active/Active

Physical Layer 3 Devices

ECMPAS Path Prepend

Edge VM 3 Edge VM 4

Availability Zone 2Availability Zone 1

Segment 1 - 192.168.100.0/24

Linux Windows Linux

Segment 2 - 192.168.200.0/24

Linux Windows Linux

Monitoring NSX-T for NSX-T Workload Domains with Multiple AvailabilityZonesMonitor the operation of NSX-T for identifying failures in the network setup by using vRealize Log Insightand vRealize Operations Manager.

n vRealize Log Insight saves log queries and alerts, and you can use dashboards for efficientmonitoring.

n vRealize Operations Manger provides alerts, capacity management and custom views anddashboards.

Architecture and Design for VMware NSX-T for Workload Domains with Multiple Availability Zones

VMware, Inc. 67

Page 68: Architecture and Design for VMware NSX-T for …...Architecture and Design for VMware NSX-T for Workload Domains with Multiple Availability Zones 03 SEP 2019 VMware Validated Design

Table 3-34. Design Decisions on Monitoring NSX-T

Decision ID Design Decision Design Justification Design Implication

NSXT-VI-SDN-050 Install the content pack forNSX-T in vRealize LogInsight.

Add a dashboard and metricsfor granular monitoring of theNSX-T infrastructure.

Requires manually installingthe content pack.

NSXT-VI-SDN-051 Configure each NSX-Tcomponent to send loginformation over syslog to thevRealize Log Insight clusterVIP.

Ensures that all NSX-Tcomponents log files areavailable for monitoring andtroubleshooting in vRealizeLog Insight.

Requires manually configuringsyslog on each NSX-Tcomponent.

Use of SSL Certificates in NSX-T for NSX-T Workload Domains with MultipleAvailability ZonesBy default, NSX-T Manager uses a self-signed Secure Sockets Layer (SSL) certificate. This certificate isnot trusted by end-user devices or Web browsers.

As a best practice, replace self-signed certificates with certificates that are signed by a third-party orenterprise Certificate Authority (CA).

Table 3-35. Design Decisions on the SSL Certificate of NSX-T Manager

Design ID Design Decision Design Justification Design Implication

NSXT-VI-SDN-052 Replace the certificate of theNSX-T Manager instanceswith a certificate that is signedby a third-party Public KeyInfrastructure.

Ensures that thecommunication betweenNSX-T administrators and theNSX-T Manager instance isencrypted by using a trustedcertificate.

Replacing and managingcertificates is an operationaloverhead.

NSXT-VI-SDN-053 Replace the NSX-T Managercluster certificate with acertificate that is signed by athird-party Public KeyInfrastructure.

Ensures that thecommunication between thevirtual IP address of the NSX-T Manager cluster andadministrators is encrypted byusing a trusted certificate.

Replacing and managingcertificates is an operationaloverhead.

Architecture and Design for VMware NSX-T for Workload Domains with Multiple Availability Zones

VMware, Inc. 68