“A structure or substance not normally present but produced by an external agent or action”

Artifacts

Page 3: Artifacts in Ct and Errors

WHAT IS CT

• Computed tomography, more commonly known as a CT or CAT scan, is a diagnostic medical test that, like traditional x-rays, produces multiple images or pictures of the inside of the body.

Page 4: Artifacts in Ct and Errors

INVENTER

• Godfrey Newbold Hounsfield 28 August 1919

Page 5: Artifacts in Ct and Errors

CT scan sketch

Page 6: Artifacts in Ct and Errors

PROTOTYPE CT SCANNER

Page 7: Artifacts in Ct and Errors

Introduction

• There are numerous kinds of artifacts that can occur in CT.

• Some affect the quality of the CT exam.

• Some are affected by patients

Page 8: Artifacts in Ct and Errors

Sources of ArtifactsHardware Issues

Page 9: Artifacts in Ct and Errors

Software problems

Page 10: Artifacts in Ct and Errors

Patients related

Page 11: Artifacts in Ct and Errors

Where susceptibility artefacts occur

• Large susceptibility artefact seen around metal screws, clips and plates

• More subtle effect seen at natural interfaces:- – iron content of haemoglobin (haemorrhage)– trabecular bone, – paranasal sinuses, – skull base, – sella.

Page 12: Artifacts in Ct and Errors

Types of Artifact

• Streak artifact• Partial volume effect• Ring artifact• Noise• Motion artifact• Windmill• Beam hardening

Page 13: Artifacts in Ct and Errors

:

Streak artifact :

Page 14: Artifacts in Ct and Errors

Partial volume effect :

Page 15: Artifacts in Ct and Errors

Ring artifact :

Page 16: Artifacts in Ct and Errors

Noise :

Page 17: Artifacts in Ct and Errors

Windmill :

Page 18: Artifacts in Ct and Errors

MOTION ARTIFACTS

Page 19: Artifacts in Ct and Errors

Classification of Artefacts

• Physics based artifacts: Results from the physical processes involved in the acquisition of CT data.

• Patient based artifacts: Caused by patient movement / presence of metallic materials in or on the patient.

• Scanner based artifacts: Results from imperfection in scanners function.

• Helical & multisection artifacts: Produced by the image reconstruction process.

Page 20: Artifacts in Ct and Errors

Classification of artefacts

• Physics based artifacts– Beam hardening artifacts. – Partial volume artifacts. – Phantom starvation.

• Patient based artifacts• Scanner based artifacts• Helical & multi-section artifacts.

Page 21: Artifacts in Ct and Errors

Beam hardening artifact:• X-ray beam is composed of individual photons with a range of

energies.• As the beam passes through the object, it becomes “harder”.

Page 22: Artifacts in Ct and Errors

Beam hardening

• The mean energy increases.

• The lower energy photons are absorbed more rapidly than the higher energy photons and it becomes harder.

Page 23: Artifacts in Ct and Errors

Two types of artifacts can result from this effect.1. Cupping artifact.

Page 24: Artifacts in Ct and Errors

2. Appearance of dark bands / streaks between dense objects in the image.

Page 25: Artifacts in Ct and Errors

Cupping artifact• X-rays passing through the

middle portion of a uniform cylinder phantom are hardened more than those passing through the edges because they are passing through more material.

• As the beam becomes harder, the rate at which it is attenuated decreases and the resultant attenuation profile differs from the ideal profile.

Page 26: Artifacts in Ct and Errors

Streaks and Dark Bands

• In very heterogeneous cross sections, dark bands or streaks appear between two dense objects in an image.

• Occurs because portion of the beam that passes through one of the objects at certain tube portions is hardened less than when it passes through both objects at other tube positions.

Page 27: Artifacts in Ct and Errors

• Can occur in – bony regions of the body– where contrast medium

has been used.

Streaks and Dark Bands

Page 28: Artifacts in Ct and Errors

Classification of artefacts

• Physics based artifacts• Patient based artifacts

– Metal artefacts– Motion artefacts– Incomplete projections

• Scanner based artifacts• Helical & multisection artifacts.

Page 29: Artifacts in Ct and Errors

METAL ARTIFACT

• Manifest itself as “star streaking” artifact.

• It’s caused by presence of metallic objects inside or outside the patient.

• Metallic object absorbs the photons causing an incomplete attenuation profile

Page 30: Artifacts in Ct and Errors

Metal Artifacts

Page 31: Artifacts in Ct and Errors

Metal Artifacts

Page 32: Artifacts in Ct and Errors

Patient based artifacts

• Metal artefacts

• Motion artefacts

• Incomplete projections

Page 33: Artifacts in Ct and Errors

Respiratory motion Motion artifact

• Respiratory motion results in ghosting artifacts and blurring that can obsure or simulate lesions.

Page 34: Artifacts in Ct and Errors

Motion-related artifacts. (a) Abdominal image obtained without breath hold shows breathing-related motion artifacts.

(b) Abdominal image obtained with breath hold shows a minimal artifact due to respiration and several motion artifacts due to cardiac pulsation.

Page 35: Artifacts in Ct and Errors

MOTION ARTIFACT CAUSED BY:

• VOLUNTARY MOTION• INVOLUNTARY MOTION

IT PRODUCES “GHOSTING” EFFECTCT IMAGE APPEARS– AS IF COMPOSED OF

SUPERIMPOSED IMAGES

Page 36: Artifacts in Ct and Errors

VOLUNTARY MOTION

Page 37: Artifacts in Ct and Errors

INVOLUNTARY MOTION

Page 38: Artifacts in Ct and Errors

Patient based artifacts

• Metal artefacts

• Motion artefacts

• Incomplete projections

Page 39: Artifacts in Ct and Errors

Incomplete Projections

• If any portion of the patient lies outside the scan field of view, the computer will have incomplete information relating to this portion and streaking or shading artifacts are likely to be generated.– Eg: arms down by the sides– IV contrast tube outside the

scan field

Page 40: Artifacts in Ct and Errors

Classification of artefacts

• Physics based artifacts• Patient based artifacts• Scanner based artifacts

– Ring artifacts– Air-contrast interface– Tube arcing– Line in topogram

Page 41: Artifacts in Ct and Errors

Ring artifacts

Ring artifacts• If one of the detector is

out of calibration on a third generation scanner (rotating x-ray tube and detector assembly), the detector will record incorrect data in each angular position, resulting in circular artifact.

Page 42: Artifacts in Ct and Errors

Ring artifacts

Ring artifacts• This misinformation is

reconstructed as a ring in the image, with the radius of the ring determined by the position of the faulty detector in the detector array.

• Scanners with solid state detectors – more prone

Page 43: Artifacts in Ct and Errors

Air-Contrast Interface

• STREAKING

• A line, mark, smear, or band differentiated by color or texture from its surroundings.

Page 44: Artifacts in Ct and Errors

Tube Arcing

• Tungsten vapor from anode and cathode intercepts the projectile electrons intended for collisions with the target.

• Crackling sound!!!! In physics a vapor (American English spelling) or vapour (British) is a substance in the gas phase at a temperature lower than its critical point, which means that the vapor can be condensed to a liquid by increasing its pressure without reducing the temperature.

Page 45: Artifacts in Ct and Errors

Line In Topogram

• Bad detector causes continuous line on the topogram

Page 46: Artifacts in Ct and Errors
Page 47: Artifacts in Ct and Errors

WHAT IS

Sa deviation from accuracy or

correctness; mistake.

Page 48: Artifacts in Ct and Errors

WHAT ARE THE ERRORS

Page 49: Artifacts in Ct and Errors

OUT OF 3 FIDUCIAL 2 ARE THERE AND BODY CUT DURRING SCAN

Page 50: Artifacts in Ct and Errors

Conclusion

• Artifacts originate from a range of sources and can degrade the quality of an image to varying degrees.

• Design features incorporated into modern scanners minimize some types of artifact, and some can be partially corrected by the scanner software.

• However, there are many instances where careful patient positioning and the optimum selection of scan parameters are the most important factors in avoiding image artifacts.

• ERRORS