Ihis report not to be guoted without prior reference to the Council" International Council for the Exploration of the Sea C.M.1989/Assess:8 REPGRT OF THE tiORKING GROUP ON CGD STOCKS OFF EAST GREENLAND Copenhaqen. 22 - 28 February 1989 Ihis document is areport of a Workinq Group of the International Council for the Exploration of the Sea and does not necessarily represent the views of the Council. Iherefore. it should not be quoted without consultation with the General Secretary. "General Secretary ICES Pal<egade 2-4 DK-1261 Copenhaqen K DENMARK

Upload: others

Post on 20-May-2020

7 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: AS83519/1 AND /2 TYPE Heat Shrink Termination (HST) Sleeves · universally accomplished with AS83519/1 and /2 type heat shrink termination (HST) sleeves. These devices, supplied in

© 2017 Glenair, Inc • 1211 Air Way, Glendale, CA 91201 • 818-247-6000 • www.glenair.com • U.S. CAGE code 06324

�� Designed to meet SAE AS83519 performance requirements

�� Fabricated from transparent cross-linked polyvinylidene fluoride tubing for optimal environmental shield termination

�� Pre-fluxed solder preform and thermally stabilized thermoplastic sealing rings to encapsulate and protect the shield-to-ground termination

�� -55ºC to 125ºC temperature range IAW SAE AS83519

Heat Shrink Termination (HST) SleevesFor EMI shield-to-ground termination

Reliable termination of EMI/RFI shielding (to ground) in wire harness applications is universally accomplished with AS83519/1 and /2 type heat shrink termination (HST)

sleeves. These devices, supplied in five different sizes—with or without pre-installed ground lead wires—provide environmental encapsulation and insulation of the shield termination site. Transparent heat shrink tubing allows for easy inspection and supplies additional strength and strain-relief. The preflux solder preform delivers a fast and controlled solder joint each and every time. Designed to meet SAE AS83519 performance requirements, Glenair Heat Shrink Termination (HST) shield to ground termination sleeves are fabricated from special transparent cross-linked polyvinylidene fluoride tubing to deliver optimal environmental shield termination in aerospace and defense industry applications. Each HST device is equipped with a pre-fluxed solder preform and thermally stabilized thermoplastic sealing rings that encapsulate and protect the shield-to-ground termination. Glenair HST devices are tested to perform from -55ºC to 125ºC IAW SAE AS83519. Best of all, these HST devices are made in the USA and stocked for immediate same-day shipment.

AS83519/1 AND /2 TYPE

Page 2: AS83519/1 AND /2 TYPE Heat Shrink Termination (HST) Sleeves · universally accomplished with AS83519/1 and /2 type heat shrink termination (HST) sleeves. These devices, supplied in

AS83519/1 AND /2 TYPE • M81824/1-1 QUALIFIEDHeat Shrink Termination Sleeves and Splices

077-010AS83519/1 Type HST SleeveNo Lead Wire

077-020AS83519/2 Type HST SleevePre-Installed Lead Wire

GS83519/1AS83519/1 Type HST SleeveNo Lead Wire

GS83519/2AS83519/2 Type HST SleevePre-Installed Lead Wire

M81824/1-1Mil-Qualified SpliceIn-Line, Insulated, Environmental

© 2017 Glenair, Inc • 1211 Air Way, Glendale, CA 91201 • 818-247-6000 • www.glenair.com • U.S. CAGE code 06324 • Heat Shrink Termination (HST) datasheet

HEAT SHRINK TERMINATION SLEEVES PRODUCT SELECTION GUIDE

AUTOMATED HST CELL ENSURES RELIABLE, REPEATABLE FABRICATION QUALITY

Glenair Heat Shrink Termination (HST) devices are supplied with pre-tinned leads including industry-standard nickel-copper per A-A-59569, Tin Copper Braid per A-A-59569, and ultra lightweight ArmorLite™ plated stainless steel microfilament.

MATERIAL/FINISH:• Insulation sleeve - Heat-shrinkable, radiation crosslinked, modified

polyvinylidene fluoride per MIL-I-23053/8. Color - Translucent blue.• Sealing ring - Thermally stabilized thermoplastic. Color - blue.• Solder - Sn63 per ANSI-J-STD-006.• Flux - ROM1 per ANSI-J-STD-004 (to be used on nickel plated shields only).• Optional thermal indicator - changes from color to colorless.