ASBESTOS INSPECTION REPORT Job Site:
1 Family Dwelling 2540 North Buffum Street
Milwaukee, Wisconsin
For:
City ofMilwaukee Department of Neighborhood Services
Attn: Marge Piwaron 841 North Broadway 1st Floor
Milwaukee, Wisconsin 53202-3613
HMG Report No.: 12-0210.2540 Contract No.: 360-12-0553
Asbestos Inspector No. All -14370
Prepared by:
HARENDA MANAGEMENT GROUP P. 0. Box 511305
New Berlin, Wisconsin 53151-2105
July 2012
P.O. Box 511305 ·New Berlin, Wisconsin 53151-2105 · (414) 383-4800 · (414) 383-4805
TABLE OF CONTENTS
I. Introduction .............. .................... .......... ...... ...... .................. ....................... .... ......... 2
II. Building Survey ..................................................... .... .......... ... ........... .... .................. 2
III. The Laboratory ....................... ........................... ....................... .. .......... .. ..... .... ......... 2 A. Method of Analysis
IV. Findings and Observations ............. ................ ................................................ .......... 3
V. Exclusions ...... ............................ .... .......................................................................... 5
VI. Limitations ..... ....... .............. .... ... .............................................................................. 5
VII. Pre-Demolition Environmental Checklist ................................................ 7
VIII. Laboratory Results .. ................................. ....... ................. .. ........ ........... ................. 11
IX. HMG Certifications ................................................................................ .. ............. 12
I Family Dwelling Asbestos Inspection 2540 NoJtb BuJfum Street Milwaukee, Wisconsin Contract# 360- 12-0553
W:/Word!HMG/ 12 Projects/12·0210.2540 July31, 20 12
HMG Project # 12-0210
I. INTRODUCTION
Harenda Management Group (HMG) was retained by the City of Milwaukee Department of Neighborhood Services to conduct an inspection for possible asbestos containing materials in the dwelling at 2540 North Buffum Street, Milwaukee, Wisconsin.
The inspection included plaster, drywall/joint compound, tar paper, paper insulation, linoleum, window glazing compound, flue packing, furnace insulation, ceiling tile, and duct paper to determine if asbestos containing materials were present within the space as required by US EPA NESHAP regulation 40 CFR 61 Subpart M
II. BUILDING SURVEY
Marge Piwaron, of the City of Milwaukee Department ofNeighborhood Services, authorized HMG to conduct a building survey and to analyze samples taken during the inspection.
On July 19, 2012, HMG conducted an asbestos inspection of a one family dwelling, scheduled for mechanical demolition, located at 2540 North Buffum Street, Milwaukee, Wisconsin. The inspection was conducted by Dean Jacobsen, Wisconsin License No. All -14370.
The inspection was comprised of three elements: 1. A visual determination as to the extent of suspect materials within the
building. 2. Sampling and documentation of observable suspect materials. Category I
nonfriable materials were assumed to be asbestos containing and not sampled.
3. Quantification of observable positive materials existing within the spaces.
The results of the survey integrated with the Polarized Light Microscopy with Dispersion Staining (PLM/DS) analysis ofbulk samples taken are outlined in this document. If you have any questions please contact HMG at (414) 383-4800.
III. THE LABORATORY
A. METHOD OF ANALYSIS
Analysis is performed by using the bulk samples for visual observation and slide preparation(s) for microscopical examination and identification. The slides are analyzed for asbestos ( chrysotile, amosite, crodcidolite, anthophyllite, and actinolite/ tremolite ), fibrous non asbestos constituents (mineral wool, paper, etc.), and nonfibrous constituents. Asbestos is identified by refractive indices (obtained by using dispersion staining), morphology, color, pleochroism, birefringence, extinction characteristics, and signs of elongation. The same characteristics are used to identify the non asbestos constituents.
I Family Dwelling Asbestos Inspection 2540 Nonh Buffum Strw }o.ifilwaukee, Wisconsin Contnct N l6G-12.0553
2 W:/Word/HMG/ 12 Projects/12..0210.2540 luly31,2012
HMG Project # 12..()210
The microscopist visually estimates relative amounts of each constituent using a stereoscope if necessary. The test results are based on a visual determination of relative volume of the bulk sample components. The results are valid only for the item tested. Current US EPA NESHAP regulations state asbestos materials means material containing more than 1% asbestos as determined using the method specified in Appendix E, Subpart E, 40 CFR Part 763 Section I, Polarized Light Microscopy. Refer to 29 CFR 1926.1101 (Construction) and 29 CFR 1910.1001 (General Industry) for specific OSHA requirements.
IV. FINDINGS AND OBSERVATIONS
The materials identified as suspect asbestos containing materials (ACM) include plaster, drywall/joint compound, tar paper, paper insulation, linoleum, window glazing compound, flue packing, furnace insulation, ceiling tile, and duct paper. These materials were sampled and the following results were noted:
Sample # Location and Description
1-2540 1 '' floor - front entry - under floor tile - paper insulation
2-2540 1 '' floor -west bedroom - under carpet - orange linoleum Quantity includes back entry & 2nd floor west bedroom
3-2540 1 '' floor - north bedroom - orange linoleum
4-2540 2n<1 floor - east bedroom - orange linoleum
5-2540a 1 '' floor- west bedroom - ceiling - plaster base coat
5-2540b 151 floor - west bedroom - ceiling - plaster skim coat
6-2540a 1 '' floor - stair- west wall- plaster base coat 6-2540b 151 floor - stair- west wall- plaster skim coat 7-2540a 151 floor - pantry - east wall - plaster base coat 7-2540b 151 floor - pantry - east wall - plaster skim coat 8-2540a 151 floor - north bedroom - north wall- plaster
base coat 8-2540b 151 floor - north bedroom - north wall- plaster
skim coat 9-2540a 2"<1 floor - west bedroom - south wall - plaster
base coat 9-2540b 2"<1 floor- west bedroom - south wall - plaster
skim coat 10-2540 2"<1 floor- east bedroom - east side - tan and
black linoleum 11-2540 2"<1 floor- west bedroom- west window -
glazing compound 12-2540 1 51 floor - pantry - north window - glazing
compound 13-2540 Basement - south window - glazing compound
I Family Dwelling Asbestos Inspection 2540 North Buffum Street 'Milwaukee, Wisconsin Contract# 360-12~553
3
Results
Negative
Positive 20% Chrysotile
Positive 20% Chrysotile
Positive 20% Chrysotile Negative
Negative
Negative Negative Negative Negative Negative
Negative
Negative
Negative
Negative
Negative
Negative
Negative
Approximate Homogeneous Quantity Code
NIA MPI
560 Sq. Ft. MFLo
Reference MFLo #2-2540
Reference MFLo #2-2540
N/A SPI
NIA SPl
N/A SPI N/A SPI N/A SPI N/A SPl N/A SPl
N/A SPl
N/A SPI
N/A SPl
N/A MFLtk
N/A MPG
N/A MPG
N/A MPG
W:/Word/HMG/12 Projects/12-02 1 0.2540 July 3 1, 2012
HMGProject # 12~2 10
Location and Description
14-2540 Basement - on chimney - west side near top -light gray flue packing
15-2540 Basement- on chimney - west side near middle -gray flue packing
16-2540 Basement- on chimney - east side - dark gray flue packing
I 7-2540 Basement - on duct near center - duct paper
18-2540 Basement - on duct west side - duct paper
19-2540 Basement - on return - duct paper
20-2540 Basement - on west side of furnace - exterior insulation
21-2540 151 floor - kitchen - east side under floor tile - tar paper
22-2540 151 floor - kitchen - west side under floor tile - tar paper
23-2540 151 floor - pantry -under floor tile - tar paper 24-2540 1st floor - kitchen - west side - 1' x 3' ceiling tile 25-2540 151 floor- kitchen - center- 1' x 3 ' ceiling tile 26-2540 151 floor - north bedroom - I ' x 3' ceiling tile 27-2540 151 floor- bathroom- yellow linoleum
28-2540 151 floor - dining room - west side - 18" ceiling tile
29-2540 151 floor - dining room - center- 18" ceiling tile 30-2540 151 floor - dining room - east side - 18" ceiling
tile 31-2540 Quality Assurance/ Quality Control Sample of
Sample 1-2540 32-2540 Quality Assurance/ Quality Control Sample of
Sample 10-2540
Notes: N/A = Not Applicable Sq. Ft. = Square Feet
Results
Positive 20% Cb_!)'Sotile
Positive 4% Cbrysotile
Positive 10% Cbrysotile
Positive 60% Cbr_ysotile
Positive 60% Cbrysotile
Positive 60% Chrysotile Negative
Negative
Negative
Negative Negative Negative Negative
Positive 20% Chrysotile Negative
Negative Negative
Negative
Negative
A ssume d c t a e~ory I N F . bl A b t C t . . M t . 1 on- na e s es os on ammg a ena: Floor Level Location Description
Approximate Homogeneous Quantity Code
1 Sq. Ft. TFPyligbt
2 Sq. Ft. TFPy
1 Sq. Ft. TFPydark
200 Sq. Ft. TDW
Reference TDW 17-2540
Reference TDW 17-2540
N/A TFE
N/A MPT
N/A MPT
N/A MPT NIA MSCT13 N/A MSCT13 N/A MSCT13
30 Sq. Ft. MFLI
N/A MSCT18
N/A MSCT18 N/A MSCT18
N/A QAQC
N/A QAQC
Approximate Quantity
Roof Dwelling A~halt Shingles & Flashing 900 Sq. Ft. 1st /2nd Dwelling Asphalt Shingle Siding
l st Front Entry/Pantry/Kitchen Floor Tile & Mastic lSI Kitchen/Living Room/Dining Floor & Wall Mastic
Room/Bathroom/Bedroom/Back Entry 2na Bedrooms Floor Mastic
Homogeneous Material Codes SPl Plaster MDW Drywall/Joint Compound MPT Tar Paper MPI Paper Insulation MPG Window Glazing Compound
I Family Dwelling Asbestos lnspoctioo 2540 North Buffiun Street Milwaukee, Wisconsin Contract # 360-12-0553
4
1,500 Sq. Ft. 600 Sq. Ft.
1,300 Sq. Ft.
400 Sq. Ft.
W:/Word/HMG/ 12 Projects/12.()2 10.2540 July 3 1, 2012
HMG Project# 12-0210
Homogeneous Material Codes MFLo Orange Linoleum MFLtk Tan & Black Linoleum MFLI Yellow Linoleum MSCT13 I' x 3' Ceiling Tile MSCT18 18" Ceiling Tile TFPy Gray Flue Packing TFPylight Light Gray Flue Packing TFPydark Dark Gray Flue Packing TDW Duct Paper TFE Exterior Furnace Insulation QA/QC Quality Assurance/Quality Control Sample
Note#l: Category I-Non-Friable Asbestos Containing Materials may become friable during mechanical demolition activities or maybe considered friable prior to demolition activities due to its current condition.
Note#2: If additional materials are discovered during demolition that are not listed above they are to be assumed to be asbestos containing.
Note#3: A copy of this report should be transmitted to the demolition contractor.
Note#4: Additional duct paper may be discovered within walls and ceilings. Exploratory demolition required for exact quantity.
Note#S: Estimated cost for friable asbestos removal
V. EXCLUSIONS
No visible or accessible areas or material were excluded from this scope of work.
HMG is not and shall not represent the building owner as its agent or representative for the purpose of the US EPAINESHAP and/or the WDNRINR447 regulations, as owner/ operator.
This report represents the condition of the building and its visible/accessible suspect asbestos containing materials at the date and the times of the onsite inspection. Hidden materials or those materials that could be present at the point of inspection, over and above those stated in the inspection report, are the responsibility of the building owner and the demolition contractor.
VI. LIMITATIONS
The care and skill given to our procedures insures the most reliable test results possible. HMG utilizes Schneider Laboratories for our Polarized Light Microscopy, unless otherwise specified by the client. The findings and conclusions ofHMG represent our professional opinions extrapolated from limited data. Significant limited data is gathered during the course of the preliminary asbestos specific site assessment. No other warranty is expressed or implied. Prior to any abatement or renovation activities, it is recommended that HMG be provided the opportunity to review such plans in order that
I Family Dwelling Asbestos Inspection 2540 Nonh Buffum Street Mil~ukee, Wisconsin Contract# 360-12-0553
5 W :/Word!HMGfl2 Projects/12-0210.2540 July 3 1, 2012
HMO Project# 12-0210
the inspection and assessments contained herein are properly interpreted and implemented.
This report and the information contained herein are prepared for the sole and exclusive use and possession of the City of Milwaukee Department of Neighborhood Services. No other person or entity may rely on this report or any information contained herein. Any dissemination of the Report or any information contained herein is strictly prohibited without prior written authorization from Harenda Management Group.
I Family Dwelling Asbestos Inspection 2540 North Bulfurn Street Mil"<Wkee, Wisconsin Con11act # 360-12~553
6 W:/Word/HMG/12 Projeas/12-021 0 .2540 July 31, 2012
HMG Project N 12~210
VII. PRE-DEMOLITION ENVIRONMENTAL CHECKLIST
1 Family Dwelling Asbestos lnspeetion 2540 North Buffum Street Milwaukee, Wisconsin Contract # 360-12-0553
7 W:/Word/HMG/12 Projeets/12-0210.2540 July 31, 2012
HMG Project # 12·0210
This guide lists materials and products commonly found in buildings with examples. It is not intended as a substitute for reading the rules and statutes and making your own independent determination of their applicability to your demolition project. These examples presented here do not represent an exhaustive listing of types of materials that may be required to be removed from the building prior to demolition.
ASBESTOS Persons conducting inspections for asbestos must hold a valid asbestos inspector certification card issued by the State of Wisconsin, Dept. of Health & Family Services. Please follow the Asbestos Inspection and Sampling Protocol for Buildings to be Demolished or Renovated.
CFCs and HALONS Equipment that may contain CFCs and Halons:
N/A Air Conditioners (rooftop, room, and central)
N/ A Dehumidifiers
N/ A Heat Pumps
N/ A Refrigerators, Freezers, Chillers
N/ A Vending Machines, Food Display Cases
N/A Walk-in Coolers
N/A Water Fountains (bubblers)
N/ A Fire Extinguishers (both portable and installed HALON suppression systems)
Nl A Water Coolers
LEAD Lead or Lead Based Paint (LBP) is common in many older buildings. When recycling construction and demolition debris, be aware that wood containing lead paint may not be chipped and spread for landscaping. State law also prohibits the sale or transfer of any fixture or other object containing LBP that might be placed upon any surface of a dwelling, which is ordinarily accessible to children.
I Family Dwelling Asbestos Insp«:tion 2540 North Bulfum Street ~1ilwaukee, Wisconsin Contract# 36().12.0553
8 W :/Word!HMG/ 12 Projects/12.0210.2540 July 31. 2012
HMG Project # 12.0210
MERCURY Products that may contain mercury:
LIGHTING 1
NIA
Fluorescent Lights - Living Room
High Intensity Discharge -Metal Halide -High Pressure Sodium -Mercury Vapor
NIA Neon
N/ A Switches for lighting using mercury relays -Look for any control associated with exterior or automated lighting systems such as "Silent" wall switches.
HVAC Check thermostats and any control associated with air handling units for switches containing mercury.
HEATING, VENTILATING AND AIR CONDITIONING SYSTEMS
1 Old Thermostats- Living Room
N/A Aquastats
NIA Firestats
N/ A Manometers
Nl A Thermometers
BOILERS, FURNACES, HEATERS, AND TANKS - 1 Furnace & 1 Water Heater in Basement
NIA Mercury Flame Sensors by pilot lights
N/ A Manometers, Thermometers, Gauges
NIA Pressure-trol
N/ A Float or Level Controls
NIA Space Heaters
I Family Dwelling Asbestos Inspection 2540 North Buffum Street .Milwaukee, Wisconsin Contract # 360- 12-0553
9 W:/Word/HMG/12 Proje<:ts/12 -02 10.2540 July 31, 2012
HMG Project# 12-Q210
ELECTRICAL SYSTEMS- 1 Breaker Box in Basement
Nl A Load Meters and Supply Relays
Nl A Phase Splitters
N/ A Microwave Relays
Nl A Mercury Displacement Relays
PCBs For electrical devices manufactured prior to 1987, it is safe to assume that they contain PCBs and should be managed accordingly. Most equipment manufactured after this time will say "PCB Free". The following is a list of areas in a building were PCBs may be found:
Nl A Transformers
N/A Capacitors (appliances, electronic equipment)
NIA Heat Transfer Equipment
Nl A Light Ballasts
Nl A Specialty Paints (such as for swimming pools or other industrial applications)
NIA Sumps or Oil Traps (in maintenance and industrial facilities)
OTHER ENVIRONMENTAL ISSUES
Nl A Hazardous Waste
1 Oil Tanks- Basement
N/ A Well Abandonment
3 Junk Auto Tires - Basement
Nl A Junk Vehicles
* 7 Gallons Paint and 1 Water Meter in Basement
I Family Dwelling Asbestos Inspection 2540 Nonh BuJ!Um Street Milwaukee. \Vi.SCOnsi.n Contract # 360-12.0553
10 W:/Word/HMG/ 12 Projeas/12.0210.2540 July 31,2012
HMG Project# 12.0210
I Family Dwelling Asbestos Inspection 2540 Nonh Buffum Street Milwaukee, Wisconsin Contract# 360-12-0553
VIII. LABORATORY RESULTS
II W:/Word/HMG/12 Projccts/12-0210.2540 July 31,2012
HMG Project # 12-0210
07/ ~1 / 201 2 12: 29 8046581708 SCHNEIDER LABS PAGE Bl/68
SCHNEIDER LABOR A TORIES GLOBAL INCORPORATED
2512 W. Cary Street • Richmond, Virginia • 23220-5117 804-353-6778 • 800-785-LABS (5227) • (FAX) 804-359-1475 Over 25 Years of Excellence in Service and Technology
AIHA/ELLAP 100527,150/IEC 17025, NVLAP 101150·0, VELAP 460135, NYELAP/NELAC 11413
LABORATORY ANALYSIS REPORT Asbestos Identification by EPA Method' 600/R-93/116
ACCOUNT#: 4001 -12·711
CLIENT: ADDRESS:
Harenda Management Group 1237 West Bruce Street
Milwaukee, WI 53204
PROJECT NAME: DNS JOB LOCATION: PROJECT NO.: 12-0210.2540
PONO.:
Client SLI Sample
Sample Sample/ ldenttrlcation/ No. layeriD Layer Name
1-2540 31542686
Layer 1: Fibrous Material Black/Beige, Fibrous
2-2540 31542687
Layer 1: Flooring Beige, Org.Bound!Fibrous
3·2540 31542688
Layer 1; Flooring Beige, Org.Bound!Fibrous
4-2540 31542689
Layer 1: Flooring Beige, Org.Bound/Fibrous
5-2540 31542690
Layer 1: Plaster Gray, Granular
Tot11l Number of Pages In Report: 5
Results relate only to samples as received by the laboratory.
Using SLI A6
DATE COLLECTED: DATE RECEIVED: DATE ANAL VZED: DATE REPORTED:
Sample Type:
7/20/2012 7/24/2012
7/25/2012
BULK
PLM Analysis Results Asbestos Fibers
None Detected
20o/o CHRYSOTILE
20% CHRYSOTILE
20o/o CHRYSOTILE
None Dotected
Other Materials
65% CELLULOSE Fl BER
15% MINERAUGLASS WOOL
20% NON FIBROUS MATERIAL
20% CELLULOSE FIBER
10o/o MINERAUGLASS WOOL
50o/o NON FIBROUS MATERIAL
20% CELLULOSE ABER
10% MINERAUGLASS WOOL 50o/a NON FIBROUS MATERIAL
20% CELLULOSE ~IBER
10% MINERAUGLASS WOOL
50o/a NON FIBROUS MATERIAL
100"/o NON FIBROUS MATERIAL
VIsit www.slabinc.com for current certifications.
Samples Bnsly=d by the EPA Test Mt:~thod :are subject to the limitation$ of liQht microsCOIJY Including matrix Interference. Gravlmerrlc reduction and correlative analyses are recommended for all non-friable, organically bovnd materials. This method has a reporting limit of 1% or greater. Visual estimation contains an Inherent range of uncertainty. This report must not be r9producsd except In full with the approval of Che lab, snd must not be used to claim NVLAP or other gov't agency endorsement.
07/31/2012 12:29 8046581708 SCHNEIDER LABS PAGE 02/ 08
Account- Workorder 4001-12-711 (Continued) Page 2 (Continued)
Client su Sample
Sample Sample/ Identification/ PLM Analysis Results No. Layer 10 Layer Name Asbestos Fibers Other Materials
Layer 2: Skim Coat None Detected 100% NON FIBROUS MATtRlAL
White, Granular
6-2540 31542691
Layer 1: Plaster None Detected 100% NON FIBROUS MATI:RtAL
Gray, Granular
Layer 2: Skim Coat None Detected 100o/. NON FIBROUS MATERIAL
White, Granular
7-2540 31542692
Layer 1: Plaster None Oetectad 100",(, NON FIBROUS MATERIAL
Gray, Granular
layer 2: Skim Coat None Detected 100o/. NON FIBROUS MATERIAl.
White, Granular
8-2540 31542693
Layer 1: Plaster None Detected 100% NON FIBROUS MATERIAL
Gray, Granular
Layer2: Skim Coat None Detected 100"/o NON FIBROUS MATERIAL
White, Granular
9-2540 31542694
Layer 1: Plaster None Detected 100% NON FIBROUS MATERIAL
Gray, Granular
Layer 2: Skim Coat None Detected 100% NON FIBROUS MATERIAL
White, Granular
10-2540 31542695
Layer 1: Flooring None Detected 35% CRLULOSE FIBER
Black/Beige, Org.Bound/Fibrous 50% NON FIBROUS MATERIAL 15% MINERAUGLASS WOOL
11-2540 31542696
Layer 1: Granular Material None Detected 100% NON FIBROUS MATERIAL
Gray, Granular
Tolal Number of Pages In Report: 5
Results relate only to samples as received by the laboratory. Visit www.slablnc.com for current certifications.
Samples analyz9d by tht!! EPA T9sl Method are subject to rhe /imitations of light microscopy including matrix interference. Gravimetric reduction and correlativfJ analyses are ftlcommended for all nan-friable, organically bound mater/8ls. This method has a reporring limit of 1% or greater. Visual estimation comains an inherenr range of uncerta/nry. This report must not be reproduced except in full with the approval of the lab, and must not be used to claim NVLAP or other go v't agency endorsement.
07 /31/2012 12:29 8046581708 SCHNEIDER LABS PAGE 03/08
Account- Workorder 4001-12-711 (Continued) Page 3 (Continued)
Client SLI Sample
Sample Sample/ Identification/ PLM Analysis Results No. LayeriD Layer Name Asbestos Fibers other Materials
12-2540 31542697
Layer 1: Granular Material Nont Detected 2'1<. CELLULOSE ABER
Beige/Brown, Granular 98% NON FIBROUS MATERIAL
13-2540 31542698
Layer1: Granular Material None Detected 2"1.. CELLULOSE FIBER
Beige/Brown, Granular 98% NON FIBROUS MATERIAL
14-2540 31542699
Layer 1; Powdery Material 20% CHRYSOTILE 80% NON FIBROUS MATERIAL
Beige, Powdery
15-2540 31542700
Layer 1: Granular Material 4o/o CHRYSOTILE 96% NON FIBROUS MATERIAL
Green/Beige, Granular
16-2540 31542701
Layer 1: Fibrous Material 10% CHRYSOTILE 40% CELLULOSE FIBER
Brown, Fibrous 20"/o MINERAUGLASS WOOL 30o/. NON FIBROUS MATERIAL
17-254{) 31542702
Layer 1: Fibrous Material 60% CHRYSOTILE 20'Yo CELLULOSE ABER
Beige, Fibrous 10.,.o MINERAUGLASS WOOL 10% NON FIBROUS MAiERIAL
18-2540 31542703
Layer 1: Fibrous Material 60% CHRYSOTILE 20% CELLULOSE FIBER
Beige, Fibrous 10% MINERAUGLASS WOOL 10o/o NON FIBROUS MATERIAL
19-2540 31542704
Layer 1; Fibrous Material 60% CHRYSOTlLE 20% CELLULOSE ABER
Beige, Fibrous 10% MINERAUGLASS WOOL 10% NON FIBROUS MATERIAL
20-2540 31542705
Layer 1: Granular Material None Detected 1 00% NON FIBROUS MATERIAL
Gray, Granular
Total Number of Pages In Report: 5
Results relate only to samples as received by the laboratory. VIsit www.slabinc.com for current certifications.
Samplt!l$ anaJyzQd by the EPA Test M9thod are sub}t!JCt to th9 limitations of light microscopy including matrix Interference. Gravimetric reduction ana correlative analyses are recommended for all non-friable, organically bound materials. This method has a r9porting limit of 1% or greater. VIsual estimation contains an inherent range of uncertainty. This report must not be reprodvced except in full with the approval of the lab, and must not be vsed to claim NVLAP or other gov't agency endorsement.
07/31/2012 12:29 8El465817El8 SCHNEIDER LABS PAGE Eld / 08
Account - Workorder 4001-12-711 (Continued) Page 4 (Continued)
Client SLI Sample Sample Sample/ Identification/ PLM Analysis Results No. L8yerl0 Layer Name Asbestos Fibers 01har Materials
21-2540 31542706
Layer 1: Fibrous Material None DGtscted 6SOJ. CELLULOSE FIBER
Brown/Black, Fibrous 15% MINERAUG~SS WOOL 20"/. NON FIBROUS MATERIAL
22·2540 31542707
Layer 1: Fibrous Material None Detected 65% CELLULOSE FIBER
Brown/Brown, Fibrous 150f. MINERAUGLASS WOOL
20% NON FIBROUS MATERIAL
23-2540 31542708
layer 1: Fibrous Material Nons Det(lcted 65% CELLULOSE FIBER
Brown/Black, Fibrous 15% MINERAUGLASS WOOL 20°/. NON FIBROUS MATERIAL
24-2540 31542709
Layer 1: Ceiling Tile None Detected 85':4 CELLUlOSE FIBER
Tan. Fibrous 15% NON FIBROUS MATERIAL
25-2540 31542710
Layer 1: Ceiling Tile None Delecttld 85% CELLULOSE FIBER
Tan, Fibrous 15% NON FIBROUS MATERIAL
26-2540 31542711
Layer 1: Ceiling Tile None Detected 85o/. CELLULOSE FIBER
Tan, Fibrous 15% NON FIBROUS MATI:RIAL
27-2540 31542712
Layer 1: Flooring 20% CHRYSOTilE 20% CELLULOSE FIBER
Tan, Org.Bound/Fibrous 10% MINERAUGLASS WOOL 50% NON FIBROUS MATERIAL
28-2540 31542713
Layer 1: Ceiling Tile None Detected 85% CELLULOSE FIBER
Tan, Fibrous 15% NON FIBROUS MATERIAL
29-2540 31542714
Layer 1: Ceiling Tile None Detected 85% CELLULOSE FIBE:R
Tan, Fibrous 15% NON FIBROUS MATERIAL
Total Number of Pages In Report: 5 Results relate only to samples as received by the laboratory. Visit www.slablnc.com for current certifications.
Samples analyziXJ by th~ EPA Test M9thod are subject to th9/imitations of light microscopy including mstrfx interference. Grsvlmarric reduction and correlsrlve analyses sre recommended for all non-friable, organically bound materials. This method has a reporting limit of 1% or greater. Visual estimation contains sn inherent range of uncertainty. This report must not be ITJproduced except in full with the approval of the lab, and must nor be used to claim NVLAP or other gov't agency endorsement.
07/3~/2012 12:29 8046581 708
Account · Workorder 4001-12-711 (Continued)
Client SLI Sample Sample Sample/ ldan1iflcatlon/ No. LayeriD L!lyerName
30-2540 31542715
layer 1: Ceiling Tile Tan, Fibrous
31-2540 31542716
Layer 1: Fibrous Material Black/Beige, Fibrous
32-2540 31542717
layer 1: Flooring Beige/Black, Org.Bound/Fibrous
Analyst: MOHAMMED B. HASHIM
Total Number of Pages In Report: 5
Results relate only to samples as received by the laboratory.
SCHNE IDER LABS PAGE 05/ 08
Page 5 (Continued)
PLM Analysis Results Asbestos Fibers
None Detected
None Detected
None Detected
Reviewed By;
Other Materials
85% CELLULOSE FIBER 1So/o NON FIBROUS MATERIAL
65% CELLULOSE FIBI:R 15% MINERAUGLASS WOOL 20% NON FIBROUS MATERIAL
35% CELLULOSE FIBER 15% MINERAUGLASS WOOL 50"/o NON FISROUS MATERIAL
Reel Hashim, Analyst
Visit www.slablnc.com for current certifications.
Samples analyzed by the EPA Tast Method are subject to the limitations of light microscopy Including matrix interlerence. Gravimetric reduction and correlative analyses are recommended for all non-friable, organice.Jiy bound materials. This m9thod has a reporting limit of 1% or greater. VIsual gstimation conralns an inherent range of unc9rtainfy. This rgport must not be reproduced except in full with the approval of the lsb, and must not be used to claim NVLAP or other gov't agency endorsement
07/31/2012 12:29 8045581708 SCHNEIDER LABS
. . . SCHNEIDER LABORATORIES, INC. Li ·. 2512 West Cary Street, Richmond, Virginia 23220-5117
. --~ 804-353-6778 • 800-785-LABS (5227) • Fax 804-359-1475
www.slabinc.com e-mail: [email protected] Submi!Dng I ~=· ., _____ _
~_£C~o·~-~~lat~•~na~M~3~~~~GM~·-~------------~W~O~a~------------------J I ~~• Phone#
.... w lertln.. WI 53151 4001
.. ~. &
PAGE 0~/08
414-383-4800
414-31~05 d)[email protected]
ProJect Name: DNS Spucfallnstructlons [(ndude reouests for SD~Ial reDortlnJL or data DaclcaaesJ
Prol.et Loeatlon: DO NOT ANALYZE MASTICS
ProJtct Number: 12·0210. ·z';5"t.tu Stet& Of Collection WI
::i~~m~~:r.-r~~~:;~:~~~~ .n~~ ~:;:~t; ::.;~(·::;:~ ·:::J~i~~.:~:~m:D.~ ii,:~~i~~ti~ldi~~r~f;~::l~·l :~:\i~~;~t~~;.~i::::!f:~~;~\ 1~. ;:1~::. ~-~~ti~~::;r.:;;.=~~•,~tii~~-i~~:~.~~~.~~·~tl i~:~,~~tii;:;:: ~ : ~~ ~;~! : ;;~r~;:~~!~~~;.':\·~~;·j1f~~:·~~f;; :: ~: ~ .. ~:;:~~~ .. D 2 hours' All umples on ronn should ba at SAME :;'~;;!~~~j;'; ~~!iai~~!:i /:': :~l.:i;~''~~~ i'Z~:~:~::;;;;;:; ·;;~; :~:;;;1:~i~f:~~:t~i:iS&UJi:i~~-:; ;rF
~ Us9 sddldons/ forms ss needed. [J Same day> 0PCM (NIOSH7400) 181 PLM lePA soo, 1982) OLQd
[J 1 bualnesa day•
O 2 bu5ine!ia day•
!BJ3 business d:w.s•
[J 5 bU&imn;s days•
D f(jl TCLP (10d)
D weeket~.s•
OAir
0Aqueou&
~B(jk
[JSotld
Owe:de
D WQS!ewater
0 HI..Vol FUtar (PM10) QWater,Drinking
0 HI-VOI Fll!er (TSP) O Compliance
CJOil 0 Wpe
0TEM (AHERA) 0 PLM (EPA Point Count) 0 RCRA Metals
LITEM {EPA Lsvslll) 0 PI.M (Qualitatiw Qnly) D ILl D NYELAP 198.1/.4/.6
ID·:<!:Mitd~~!ri~Uf~e~ii . ::::(;: 0 CAELAP (EPA Interim)
OTo1al Dusl(NIOSH 0500) [JTeM (Chlll11eld) r::JTCLP /lead
O!taap. Dt.lat(NIOSH 0600) p.ln--. _________ -IDTCL.P I RCRAMetals
• not available for all tests D Paint D Wipe, Composite 0SIIIea. FTIR (NJOSH 7602) FOR ASBESTOS AIR: nTCLP I Full (w/ onJanics)
$chodulo na1t O'iao!ler. mulfl. 0 Sludge 0 ------ 0Siica - XRD (NIOSH 7500) TYPE OF RESPIRATOR f, · ~· .. -;.:-i·:.;i ::_:;_;;;~~ ·,~ . -~:::::f.f}R~:u:!~J'~~ meujJHaW:::.!':..tl~ln .-So~ 0 10 USED: 0
Sample#
l -2.71-to
2.-'2.5"<0
5·25l.(o
1-2-S<to
Date Sampled
Time Sampled
Sample ldenUflcaUon (e.q. Emplovee SSN Bldj:~. Ma:t.erial)_
Wiped Type1 11me2 · Raw Rate~ .. -.. . Area (ltl) A B P.EI---S-ta-rt--.--5-~top---+--S-t_a_rt--r---S-to--p~
Totat4 Air Vol
1Typa: A=area B=bla~tk P•peraonel E=axcuralon 2eeglnnln!J(I:nd of Sample Period 3Pump Calibl"lltlon In LltereiMinuta 4voluma In Litera [tlmeln mint\ flow In Umhl]
isampled by Relinquished to lab by ( !\.~~ NAME NAMe Dean Jacobsen ~~
,r:/ fT'-' OweD:~ B I /A) f $1GNA1'URE SJGNA1'UR~ / . :'t{)LJ-pATEITIME DATEITlME "'\_ ... {;9/12 17:00 ./ ~ .._.. v
\ / ,-j ~ ID Samole return reauested 0 Ambient temo 0 Ice °C DH Cl DR Y"S D X .... · n corotinur:tf inlr!monv within li>b. Tcvms :md condi6onB IJIH162.
~
07/ ~1 /2012 12:29 8045581708 SCHNEIDER LABS PAGE El7/08
,.[i . ~~~-
SCHNEIDER LABORATORIES, INC. 2512 West Cary Street, Richmond, Virginia 23220-5117
804-353-6778 • 800-785-LABS (5227) ·Fax 804-359-1475
www.slabinc.com e-mail: [email protected]
Submitting I ~=· ~~C~o~. --~~·~·e~n~u~M~an~·~~·m~Mrt~~G~~~L-----------~WOI
WOU!Iel:
... o. Ilene 511305
1-:"r.co"'"ouJn-------------------i I"P!®o • Fax•
4001 &
414-383·4800
414-383-41105 d)acobsen@harend•.coorn
for,_t_ect Name: DNS Spociallnstntctlons flntluda rfKl~uts for 1111eciat reDortlntt or daUJ DM:kaaesl
Project location: DO NOT ANALYZE MASTICS
Proiect Number: 12-0210. '2 51{<:> ~ Stale Of Collection I.--nLNumbtr. IINI i;ir,it;~~~, i<rliiirid'r111~i<t : :.: ,,_;)'~~~~;&~:r:,;~ %~i~~:o~~'~'';'<, ::,~~V .. ;';.::::r.f:p;if.;'~ ·:::':::::i'.;-~:;'<'· ;'::r'~&:i·~~~~~ i~i~~,~~~,~t'i·;~I~G;~; ;_ ;·;rJt · ·,: :;~~;:,i;;i;:_~;:::~1i:·,;'~:i. Clz hou/'11· M ssmptss on fotrn should be of SAME :·A~~~ "~i'/~\li.~:~~~- ' · .-:.: :~~bc;~~~~liW~~b~io·i.:: · ;i !~,i; ~::~·~~~~ii~~ic~~~i[~jj~·y ;.i
!J!Oirir jyp& Uso eddtt/Onst fbrms as needed. D Same day• 0PCM (NJOSH HDO) 1!1 PLM (EPA 600, 1982) 0Lead
QAir
0Aqueous
!B) Bulk
Osolid owaa!a
0WasleWater
0 H._ Vol Filtllr (PM1 D) 0 Watar.Omking
O HI-Vol Fi~r (TSP) 0 Compliance
0TEM (AHERA) 0 PLM {EPA Point Count)
0TEM (EPA l.evelll) 0 PLM (QuaJJtaUve only)
D 0 NYEI.AP 198.1/.41.6
~-;)(~-~-.~~~;;i;~f~l::~- - . 0 CAELAP (EPA Interim)
0RCRAMebl&
D 0
onar O..Cat (NIOSH OSOO) D TEM (Chatfield) D TCLP /lee.d
0 1 buslne3s 12sy•
0 2 busin85& day'
[813 buslnaaa day&•
0 5 bU$lneu .Uys•
D Full TCLP {1 Od)
0Weekend• oou D wrpe OResp. oust (NrosH osoo) l'"ln.._ _______ -iD rcLP r RCRA Metal&
• not available for illl tests D Paint 0 \/VIpe, Compoa~e 0Siliea • FTIR (NIOSH 7602) FOR ASBESTOS AIR: lnTCLP I Full (w/ organics}
Schedule Nlll OlfiB/1/U, mu~ [J Sludge IIMI8II & waakend 141strin f..-,
0 0S~ie4 • XRO (NIOSH 7!00) TYPE OF RESPIRATOR
e~IIU. ILJ Sotl D 0 usee· lo Oate 11me Sample JdenlltlcaUon · • - \Mped l)'pe 1 Tim at · Flow Rata' ·
(e.Q. Emplovee SSN BldQ. Material) Area lft"l A_.B ~-1--s=-ta-rt,--:.;F-S-::-t-oo--+-"'"'s-ta...:rt-=;r-:-.:::=s:...tOP-----4 Total' Air Vol Samole# Samoled Samoled
(~ ·2?1-o
1Type; A=area Bllblank P-peraonal E=excunlon :leeglnnlng/End of ~mple Period sPump Callbr.ttlon In Lltan!Minute
f':;ampled by Rallnqulshad to lab by
~AME NAME Dea~Jacobsen
SIGNATURE ~IGNATU~E r:k~ DATE/TIME PATE/TIME -,.. UQ/12 17·00
[J Sample retum reauasled Ambient te:mo Ice
'Volum•ln Liters (lime In min • flow In Umln]
DFX []UPS 1:1 U9M []HD [J DB
WB; _ _ _
07/31/2012 12:29 8045581708 SCHNEIDER LABS PAGE 08/08
SCHNEIDER LABORATORIES, INC. 2512 West Cary Street. Richmond, Virginia 23220-5117
804-353-ene • eoo-785--LABS (5227) ·Fax 804-359-1475
www.slabinc.com e-mail: [email protected]
WOLab1l:
414-383-4800 ,,o. lloJt 811305
4001 414-383-4805
cQac:obsonQharenda.com
ProJect N1111J1: JlNS SJJ«IIJIInstrucfJons I include requests for spfiCIIII reporting_ or data pc~c#r.Jg96J
Protect Loc.tlon; DO NOT ANALYZE MASTICS
ProJtct Number: 12..()210. ~ 5'<.-o .__ Stat. Of Collection L ---1 n.o Number. IV\11 (ii/~iiii;;~~t~:~-ii~ .:+ ~): ;-·· -~~IJ~ -i ~i~.TY~:(~~,~~~i!if::,:, .': :::/~:-~, ·,,,;t~r.~t.( .- ;_, :<;~1:r;;r .. +~':t-i~Mitt;~~iAtt~'~t ~~~)·,-:/~~#:;::-:: ,, __ ,~:;~z:~!::t:)_.~;i:f 0 ~ hour-5" An sampleS on form should be of SAME .; ,~~~~it; /~i~~'td~~i- :,t·~: A~b;;~tl;~1~!k';~~~:fi:i:)J} J-:');'-t;~tt~tl~,~~?i::;:~:--~;;
matrix tvpe_ vse ae1t11ttonal forms es needed. 0Sarrt41 dooy< OPCM (NIOSH 7-400) ~PLM (EPA600,1982) 0Lead
0Air
0AquOOU$
1BJ Bulk
0Bolid
0WB&III
0 \Naatawater
0 Hi-Vol Filt.r (PM1 0) 0 Wa!sr,Orinking
CJ HJ..Vol Fittw (TSP) O Compliance
CJTEM (AHEAA) 0 PLM (EPA Pofnl Counl) ORCRAMebts
CJTEM (EPA leve111) CJ PLM (Qualltadve only) 0 D D NYE~P 198.1/ ... /.6 n i ;!_:;;~·f.illj~~.ih'~~; i~~=;-.;;;,:~,~;- D CAELAP (EPA lnrem)
CJTo131 Ou.st (NIOSH 0500) 0 TEM (Chatfield) 0 TCLP I Lead
CJ 1 busine5S day•
0 2 bu&inn& day"
IBJ3 bu&ina&& days•
0 5 buaine&& da)'$"
0 FuU TCLP (10d)
Oweekeno• CJ 08 [J Wipe 0Rosp. 011~1 (NIOSH 0600) 1'"10....__ _______ -lOTCLP I RCRA Metals
• not available fol' all tests QPainl D IMpe, Composite CJSnice- FTIR (NIOSH 7802) FOR ASBESTOS AIR: inTCLP I Full CWI omanlcsl
0 ----- CJSitiea • XRO (NIOSH 7500) TYPE OF RESPIRATOR
Date Time Sample# Samoled Samoled
0 0 · Sample tdenllllcatlon · · ·
(e.a. Emolovee SSN Bldg, Malarial\
USED: 0 Wiped Type 1 Tlme2 Flow Rate,
Area (!rl A B P .J;J---:S-tart___.:..::.r::....S_t_oo- +--S-ta...:rt...:.::.:;...:....:::;.;.S;;..t_oo--1 Total4
Air Vol
1rype: Aaaraa B=blank P•pen~onal E=eJCcuralon 2t~eglnnlng/End of S11111pla PeriOd 3Pump C•ffbratlon In UIOrs/Mlnuto "volume In Lltera(tlmaln min • flow In Umln)
Sampled by Relinquislled to tab by
NAME NAME Dean Jacobsen
SIGNATlJ~E: StGNAT\JR..,l__.~"""\----1'>....:;:_-----DATEITlME DATE/TIME 7/19/12 17-00
Samole relum reai.JEl&led 0 Ambient temo [] Ice "C oH Cl DR OS OX hla!n.oi-Cu•~nm~
DFX 0UPS OVSM CJ HO [JOB we: ___ l
· n <:x>nlinur:d illlern8flv wilhitl lab. Tetms IIJid condlrlons ,.,., 2
I Family Dwelling Asbestos Inspection 2540 Nonh Buffum Street Milwaukee, Wt>COnsin Contract# 360-12-0553
IX. HMG CERTIFICATION
12 W:/Word/HMG/ 12 Projects/12-0210.2540 July31, 201 2
HMG Project# 12-0210
ASBESTOS INSPECTOR .. l\>i>>CClBr
• • • STATEOFWISCONSlN
1)ept. ofHealth Ser-vices
ti5o lbs s os· 12/l!ll96J Male
P.O. Box 511305 · New Berlin, Wisconsin 53151-2105 · (414) 383-4800 · (414) 383-4805
ASBESTOS INSPECTION REPORT
Job Site:
1 Family Dwelling
5012 West Medford Avenue
Milwaukee, Wisconsin
For:
City of Milwaukee
Department of Neighborhood Services
Attn: Marge Piwaron
841 North Broadway 1st Floor
Milwaukee, Wisconsin 53202-3613
HMG Report No.: 13-2000-068.5012
Contract No.: 360-13-0745
________________________ Dean Jacobsen
Asbestos Inspector No. AII – 14370
Prepared by:
HARENDA MANAGEMENT GROUP
P. O. Box 511305
New Berlin, Wisconsin 53151-2105
June 2013
1 Family Dwelling Asbestos Inspection W:/Word/HMG/13 Projects/13-2000-068.5012
5012 West Medford Avenue June 19, 2013
Milwaukee, Wisconsin HMG Project # 13-2000-068.5012
Contract # 360-13-0745
1
TABLE OF CONTENTS
I. Introduction ..............................................................................................................2
II. Building Survey .......................................................................................................2
III. The Laboratory .........................................................................................................2
A. Method of Analysis
IV. Findings and Observations .......................................................................................3
V. Exclusions ................................................................................................................5
VI. Limitations ...............................................................................................................5
VII. Pre-Demolition Environmental Checklist…………………………………………6
VIII. Laboratory Results .................................................................................................10
IX. HMG Certifications ...............................................................................................11
1 Family Dwelling Asbestos Inspection W:/Word/HMG/13 Projects/13-2000-068.5012
5012 West Medford Avenue June 19, 2013
Milwaukee, Wisconsin HMG Project # 13-2000-068.5012
Contract # 360-13-0745
2
I. INTRODUCTION
Harenda Management Group (HMG) was retained by the City of Milwaukee Department
of Neighborhood Services to conduct an inspection for possible asbestos containing
materials in the dwelling at 5012 West Medford Avenue, Milwaukee, Wisconsin.
The inspection included linoleum, ceiling tile, ceiling tile glue pods, drywall with texture,
tar paper, window glazing compound and attic insulation to determine if asbestos
containing materials were present within the space as required by US EPA NESHAP
regulation 40 CFR 61 Subpart M.
II. BUILDING SURVEY
Marge Piwaron, of the City of Milwaukee Department of Neighborhood Services,
authorized HMG to conduct a building survey and to analyze samples taken during the
inspection.
On June 04, 2013, HMG conducted an asbestos inspection of a one family dwelling
scheduled for mechanical demolition, located at 5012 West Medford Avenue,
Milwaukee, Wisconsin. The inspection was conducted by Craig Dekutowski,
Wisconsin License No. AII – 500.
The inspection was comprised of three elements:
1. A visual determination as to the extent of suspect materials within the
building.
2. Sampling and documentation of observable suspect materials. Category I
nonfriable materials were assumed to be asbestos containing and not
sampled.
3. Quantification of observable positive materials existing within the spaces.
The results of the survey integrated with the Polarized Light Microscopy with Dispersion
Staining (PLM/DS) analysis of bulk samples taken are outlined in this document. If you
have any questions please contact HMG at (414) 383-4800.
III. THE LABORATORY
A. METHOD OF ANALYSIS
Analysis is performed by using the bulk samples for visual observation and slide
preparation(s) for microscopical examination and identification. The slides are analyzed
for asbestos (chrysotile, amosite, crodcidolite, anthophyllite, and actinolite/ tremolite),
fibrous non asbestos constituents (mineral wool, paper, etc.), and nonfibrous constituents.
Asbestos is identified by refractive indices (obtained by using dispersion staining),
morphology, color, pleochroism, birefringence, extinction characteristics, and signs of
elongation. The same characteristics are used to identify the non asbestos constituents.
1 Family Dwelling Asbestos Inspection W:/Word/HMG/13 Projects/13-2000-068.5012
5012 West Medford Avenue June 19, 2013
Milwaukee, Wisconsin HMG Project # 13-2000-068.5012
Contract # 360-13-0745
3
The microscopist visually estimates relative amounts of each constituent using a
stereoscope if necessary. The test results are based on a visual determination of relative
volume of the bulk sample components. The results are valid only for the item tested.
Current US EPA NESHAP regulations state asbestos materials means material containing
more than 1% asbestos as determined using the method specified in Appendix E, Subpart
E, 40 CFR Part 763 Section I, Polarized Light Microscopy. Refer to 29 CFR 1926.1101
(Construction) and 29 CFR 1910.1001 (General Industry) for specific OSHA
requirements.
IV. FINDINGS AND OBSERVATIONS
The materials identified as suspect asbestos containing materials (ACM) linoleum, ceiling
tile, ceiling tile glue pods, drywall with texture, tar paper, window glazing compound and
attic insulation. These materials were sampled and the following results were noted:
Sample # Location and Description Results Approximate
Quantity
Homogeneous
Code
1-5012 1st floor – south east entrance – west side – light
brown linoleum
Negative N/A MFLn light
2-5012 1st floor – kitchen – top layer – white/tan linoleum Negative N/A MFLwt
3-5012 1st floor – kitchen – middle layer – tan/gray
linoleum
Negative N/A MFLty
4-5012a 1st floor – kitchen – bottom layer – beige/pink
linoleum
Negative N/A MFLep
4-5012b 1st floor – kitchen – bottom layer – linoleum Negative N/A MFLep
4-5012c 1st floor – kitchen – bottom layer – tan/brown
floor tile
Negative N/A MFLep
5-5012 1st floor – bathroom – top layer – dark brown
linoleum
Negative N/A MFLn dark
6-5012 1st floor – bathroom – 2nd layer – dark gray
linoleum
Negative N/A MFLy dark
7-5012 1st floor – bathroom – 3rd layer – light gray
linoleum
Negative N/A MFLy light
8-5012a 1st floor – bathroom – 4th layer – tan linoleum Negative N/A MFLt
8-5012b 1st floor – bathroom – 4th layer – cream linoleum Negative N/A MFLc
9-5012 1st floor – south east entrance – cream 9”x9”
ceiling tile
Negative N/A MSCT9x9c
10-5012 1st floor – kitchen – white 2’x4’ ceiling tile Negative N/A MSCT2x4w
11-5012 1st floor – living room – off white 2’x4’ ceiling
tile
Negative N/A MSCT2x4w –
off
12-5012 1st floor – bedroom – cream 2’x4’ ceiling tile Negative N/A MSCT2x4c
13-5012 1st floor – north east room – white 9”x9” ceiling
tile
Negative N/A MSCT9x9w
14-5012 1st floor – south east entrance – tan ceiling tile
glue pod
Negative N/A MGPt
15-5012 1st floor – living room – brown ceiling tile glue
pod
Negative N/A MGPn
16-5012 1st floor – north east room – dark brown ceiling
tile glue pod
Negative N/A MGPn dark
17-5012 1st floor – south east entrance – north east wall –
texture
Negative N/A STX
1 Family Dwelling Asbestos Inspection W:/Word/HMG/13 Projects/13-2000-068.5012
5012 West Medford Avenue June 19, 2013
Milwaukee, Wisconsin HMG Project # 13-2000-068.5012
Contract # 360-13-0745
4
Sample # Location and Description Results Approximate
Quantity
Homogeneous
Code
18-5012a 1st floor – living room – beneath floor tile – black
tar paper
Negative N/A MPT
18-5012b 1st floor – living room – beneath floor tile – black
tar
Negative N/A MPT
19-5012 1st floor – bedroom – beneath floor tile – black tar
paper
Negative N/A MPT
20-5012 1st floor – south east entrance – transite pipe Positive 20%
Chrysotile
12 Ln. Ft. MTP
21-5012 1st floor – west entrance – near front door –
window glazing compound
Negative N/A MPG
22-5012 2nd floor – attic crawlspace – blown in insulation Negative N/A MBI
Notes: N/A = Not Applicable
Sq. Ft. = Square Feet
Assumed Category I Non-Friable Asbestos Containing Material:
Floor Level Location Description Approximate Quantity
Roof Dwelling Asphalt Shingles & Flashing 300 Sq. Ft.
1st South East Room/Living Room &
Bedroom
Floor Tile & Mastic 230 Sq. Ft.
Homogeneous Material Codes
MFLn light Light Brown Linoleum
MFLwt White/Tan Linoleum
MFLty Tan/Gray Linoleum
MFLep Beige/Pink Linoleum
MFLn dark Dark Brown Linoleum
MFLy dark Dark Gray Linoleum
MFLy light Light Gray Linoleum
MFLt Tan Linoleum
MSCT9x9c Cream 9”x9” Ceiling Tile
MSCT2x4w White 2’x4’ Ceiling Tile
MSCT2x4w-off Off White 2’x4’ Ceiling Tile
MSCT2x4c Cream 2’x4’ Ceiling tile
MSCT9x9w White 9”x9” Ceiling Tile
MGPt Tan Ceiling Tile Glue Pod
MGPn Brown Ceiling Tile Glue Pod
MGPn dark Dark Brown Ceiling Tile Glue Pod
STX Texture
MPT Tar Paper
MTP Transite Pipe
MPG Window Glazing Compound
MBI Blown in Insulation
Note#1: Category I – Non-Friable Asbestos Containing Materials may become friable during mechanical
demolition activities or maybe considered friable prior to demolition activities due to its current
condition.
Note#2: If additional materials are discovered during demolition that are not listed above they are to be
assumed to be asbestos containing.
Note#3: A copy of this report should be transmitted to the demolition contractor.
1 Family Dwelling Asbestos Inspection W:/Word/HMG/13 Projects/13-2000-068.5012
5012 West Medford Avenue June 19, 2013
Milwaukee, Wisconsin HMG Project # 13-2000-068.5012
Contract # 360-13-0745
5
Note#4: Additional transite piping may be discovered between structural walls and ceilings. Exploratory
demolition is required for exact quantity.
Note#5: Estimated cost for friable asbestos removal…
V. EXCLUSIONS
Attic not accessible. Roof visible only from ground. No other visible or accessible
areas or material were excluded from this scope of work.
HMG is not and shall not represent the building owner as its agent or representative for
the purpose of the US EPA/NESHAP and/or the WDNR/NR447 regulations, as
owner/operator.
This report represents the condition of the building and its visible/accessible suspect
asbestos containing materials at the date and the times of the onsite inspection. Hidden
materials or those materials that could be present at the point of inspection, over and
above those stated in the inspection report, are the responsibility of the building owner
and the demolition contractor.
VI. LIMITATIONS
The care and skill given to our procedures insures the most reliable test results possible.
HMG utilizes Quantem Laboratories for our Polarized Light Microscopy, unless
otherwise specified by the client. The findings and conclusions of HMG represent our
professional opinions extrapolated from limited data. Significant limited data is gathered
during the course of the preliminary asbestos specific site assessment. No other warranty
is expressed or implied. Prior to any abatement or renovation activities, it is
recommended that HMG be provided the opportunity to review such plans in order that
the inspection and assessments contained herein are properly interpreted and
implemented.
This report and the information contained herein are prepared for the sole and exclusive
use and possession of the City of Milwaukee Department of Neighborhood Services. No
other person or entity may rely on this report or any information contained herein. Any
dissemination of the Report or any information contained herein is strictly prohibited
without prior written authorization from Harenda Management Group.
1 Family Dwelling Asbestos Inspection W:/Word/HMG/13 Projects/13-2000-068.5012
5012 West Medford Avenue June 19, 2013
Milwaukee, Wisconsin HMG Project # 13-2000-068.5012
Contract # 360-13-0745
6
VII. PRE-DEMOLITION ENVIRONMENTAL CHECKLIST
1 Family Dwelling Asbestos Inspection W:/Word/HMG/13 Projects/13-2000-068.5012
5012 West Medford Avenue June 19, 2013
Milwaukee, Wisconsin HMG Project # 13-2000-068.5012
Contract # 360-13-0745
7
This guide lists materials and products commonly found in buildings with examples. It is
not intended as a substitute for reading the rules and statutes and making your own
independent determination of their applicability to your demolition project. These
examples presented here do not represent an exhaustive listing of types of materials that
may be required to be removed from the building prior to demolition.
ASBESTOS
Persons conducting inspections for asbestos must hold a valid asbestos inspector
certification card issued by the State of Wisconsin, Dept. of Health & Family Services.
Please follow the Asbestos Inspection and Sampling Protocol for Buildings to be
Demolished or Renovated.
CFCs and HALONS
Equipment that may contain CFCs and Halons:
N/A Air Conditioners (roof top, room, and central)
N/A Dehumidifiers
N/A Heat Pumps
N/A Refrigerators, Freezers, Chillers
N/A Vending Machines, Food Display Cases
N/A Walk-in Coolers
N/A Water Fountains (bubblers)
N/A Fire Extinguishers (both portable and installed HALON
suppression systems)
N/A Water Coolers
LEAD
Lead or Lead Based Paint (LBP) is common in many older buildings. When recycling
construction and demolition debris, be aware that wood containing lead paint may not be
chipped and spread for landscaping. State law also prohibits the sale or transfer of any
fixture or other object containing LBP that might be placed upon any surface of a
dwelling, which is ordinarily accessible to children.
1 Family Dwelling Asbestos Inspection W:/Word/HMG/13 Projects/13-2000-068.5012
5012 West Medford Avenue June 19, 2013
Milwaukee, Wisconsin HMG Project # 13-2000-068.5012
Contract # 360-13-0745
8
MERCURY
Products that may contain mercury:
LIGHTING
N/A Fluorescent Lights
N/A High Intensity Discharge
-Metal Halide
-High Pressure Sodium
-Mercury Vapor
N/A Neon
N/A Switches for lighting using mercury relays
-Look for any control associated with exterior or automated
lighting systems such as "Silent" wall switches.
HVAC
Check thermostats and any control associated with air handling units for switches
containing mercury.
HEATING, VENTILATING AND AIR CONDITIONING SYSTEMS
N/A Old Thermostats
N/A Aquastats
N/A Firestats
N/A Manometers
N/A Thermometers
BOILERS, FURNACES, HEATERS AND TANKS
N/A Mercury Flame Sensors by pilot lights
N/A Manometers, Thermometers, Gauges
N/A Pressure-trol
N/A Float or Level Controls
N/A Space Heaters
1 Family Dwelling Asbestos Inspection W:/Word/HMG/13 Projects/13-2000-068.5012
5012 West Medford Avenue June 19, 2013
Milwaukee, Wisconsin HMG Project # 13-2000-068.5012
Contract # 360-13-0745
9
ELECTRICAL SYSTEMS
N/A Load Meters and Supply Relays
N/A Phase Splitters
N/A Microwave Relays
N/A Mercury Displacement Relays
PCBs
For electrical devices manufactured prior to 1987, it is safe to assume that they contain
PCBs and should be managed accordingly. Most equipment manufactured after this time
will say "PCB Free". The following is a list of areas in a building were PCBs may be
found:
N/A Transformers
N/A Capacitors (appliances, electronic equipment)
N/A Heat Transfer Equipment
N/A Light Ballasts
N/A Specialty Paints (such as for swimming pools or other industrial
applications)
N/A Sumps or Oil Traps (in maintenance and industrial facilities)
OTHER ENVIRONMENTAL ISSUES
N/A Hazardous Waste
N/A Oil Tanks
N/A Well Abandonment
N/A Junk Auto Tires
N/A Junk Vehicles
* 1 Gas Meter – Exterior
1 Family Dwelling Asbestos Inspection W:/Word/HMG/13 Projects/13-2000-068.5012
5012 West Medford Avenue June 19, 2013
Milwaukee, Wisconsin HMG Project # 13-2000-068.5012
Contract # 360-13-0745
10
VIII. LABORATORY RESULTS
2033 Heritage Park Drive I Oklahoma City, OK 73120 I (405) 755-7272/ Fax (405) 755-2058
Polarized Light Microscopy Asbestos Analysis Report
QuanTEM Lab No. 222427 Client: Harenda Management Group Jolene Harenda Account Number: B929
Date Received:
Received By:
Date Analyzed:
Analyzed By:
Methodology:
QuanTEM Sample ill
06/06/2013
Joanna Mueller
06/11/2013
Sandy Baker
EPA/600/R-93/116
Client Sample ID Composition
P.O. Box 511305 New Berlin, WI 53151-2105
Project: DNS
Project Location: Milwaukee, Wl
Project Number: 13-2000-068.5012
Color I Description Asbestos (%)
Non-Asbestos Fiber(%)
Non Fibrous
----------------------------· ------
006 6-5012
007 7-5012
008 8-5012
008a
009 9-5012
010 10-5012
011 11-5012
Homogeneous
Homogeneous
Layered
Layered
Homogeneous
Homogeneous
Homogeneous
Tan
Floor Tile
Tan
Sheet Vinyl
Gray
Sheet Vinyl Backing
Cream
Sheet Vinyl
Cream
Ceiling Tile
White
Ceiling Tile
White
Ceiling Tile
Asbestos Not Present
Asbestos Not Present
Asbestos Not Present
Asbestos Not Present
Asbestos Not Present
Asbestos Not Present
Asbestos Not Present
Unless otherwise noted, upon receipt the condition of the sample was acceptable for analysis.
NA Vinyl CaC03
Cellulose 10 Vinyl Glass Fiber 5 Binder
Glass Fiber 5 Binder
Synthetic 5
Cellulose 10 Vinyl Binder
Glass Fiber 90 Paint
Cellulose 55 Perlite
Glass Fiber 5 Paint
Cellulose 30 Perlite
Glass Fiber 30 Paint
QuanTEM is a NVLAP accredited TEM and PLM laboratory (Lab Code: 101959-0). This report relates only to the specific items tested. NVLAP accreditation applies only to analysis performed utilizing EPA/6001M4-82-020 and EPA/600/R-93/116 methods. This report may not be used to claim product endorsement byNVLAP or any
other agency of the US Government. This report may not be reproduced except in full, without the written approval of the laboratory_
Page 2 of 4
2033 Heritage Park Drive 1 Oklahoma City, OK 73120 I (405) 755-7272 1 Fax (405) 755-2058
Polarized Light Microscopy Asbestos Analysis Report
QuanTEM Lab No. 222427 Client: Harenda Management Group
Account Number: B929 Jolene Harenda P.O. Box 511305
Date Received: . 06/06/2013 New Berlin, WI 53 151-2105 Received By: Joanna Mueller
Date Analyzed: 06/ 11/2013 . Project: DNS
Analyzed By: Sandy Baker Project Location: Milwaukee, WI
Methodology: EPA/600/R-93/ 116 Project Number: 13-2000-068.5012
QuanTEM Client Color I Non-Asbestos 1'-ion Fibrous SampleiD Sample ID Composition Description Asbestos (%) Fiber(%)
... ~- ····-·--------012 12-5012 Homogeneous Wbite Asbestos Not Present Cellulose 30 Perlite
Ceiling Tile Glass Fiber 30 Paint
013 13-5012 Homogeneous White Asbestos Not Present Glass Fiber 90 Paint
Ceiling Tile
014 14-5012 Layered White Asbestos Not Present Glass Fiber 90 Paint
Ceiling Tile
014a Layered Brown Asbestos :Not Present NA Glue
Mastic
015 15-5012 Homogeneous Brov.n Asbestos ?'lot Present NA Glue
Mastic
016 16-5012 Homogeneous Brov.n Asbestos Not Present NA Glue
Mastic
01 7 17-5012 Homogeneous Green Asbestos Not Present NA CaCOJ
Texture Paint
Unless otherwise noted, upon receipt the condition of the sample was acceptable for. analysis.
QuanTEM is a NVL.u> accredited TEM and PLM laboratol)· (Lab Code: 101959-0). This report relates only to the specific items tested. NVLAP accreditation applies only to analysis performed utilizingEPN600/M4-82-020 and EPN600/R-93/ll6 methods. This report may not be used to claim product endorsement by N'v'LAP or any
other agency of the US Government. This report may not be reproduced except in full, without the v.ritten approval of the laboratory.
·Page 3 of 4
®
2033 Heritage Park Drive I Oklahoma City, OK 73120 I (405) 755-7272/ Fax (405) 755-2058
Polarized Light Microscopy Asbestos Analysis Report
QuanTEM Lab No. 222427 Client: Harenda Management Group Jolene Harenda Account Number: B929
06/06/2013 Date Received:
Received By:
Date Analyzed:
Analyzed By:
Methodology:
QuanTEM Sample ID
018
018a
019
020
021
022
J canna Mueller
06/11/2013
Sandy Baker
EPA/600/R-93/116
Client Sample ID
18-5012
19-5012
20-5012
21-5012
22-5012
Composition
Layered
Layered
Homogeneous
Homogeneous
Homogeneous
Homogeneous
P.O. Box 511305 New Berlin, WI 53151-2105
Project DNS
Project Location: Ivlilwaukee, WI
Project Number: 13-2000-068.5012
Color I Description Asbestos(%)
Non-Asbestos Fiber(%)
Non Fibrous
···-------------------------------
Black
TarPaper
Black
Tar
Black
Tar Paper
Gray
Transite
Tan
Window Glazing
Brov.n
Insulation
Asbestos Not Present
Asbestos Not Present
Asbestos Not Present
Asbestos Present
Chrysotile 20
Asbestos Not Present
Asbestos ~ot Present
6/11!2013
Date of Report
Cellulose 60 Tar
NA
NA
KA
NA
Cellulose 100
Tar
Tar
Quartz CaC03
CaCOJ Paint
Unless otherwise noted, upon receipt the condition of the sample was acceptable for analysis.
QuanTEM is a NVLAP accredited TEM and PLM laboratory (Lab Code: 101959-0) _ This report relates only to the specific items tested_ NVLAP accreditation applies only to analys is performed utilizing EPAI600!1vf4-82-020 and EPA/600./R-93/116 methods . This report may not be used to claim product endorsement by NVLAP or any
other agency of the US Government. This report may not be reproduced except in full, without the written approval of the laboratory_
Page 4 of 4
._.MauRATORIES www.QuanTEM.com
ASBESTOS CHAIN OF CUSTODY 2033 Heritage Park Drive, Oklahoma City, OK 73120-7502 (800) 822-1650 • (405) 755-7272 • Fax: (405) 755-2058
LEGAL DoCUMENT ;. PLEASE PRINT LEGIBLY '
Projectlocation: Milwaukee, WI --------------------·
1 3-2000-068.5012
r::~~:>£·~\[~}fj.;:i'f<';;:~· >.jr ., .. t , · ,, 0:.:./ .. •. II _·· _.· , Y'"li' ..... , ......... , .... .• lr·.o'•"·'•.··)·"'···,:·•····
Air- NIOSH 7402 Bulk- Quantitative [weight%)- Chatfield
Air-15010312
Drinking Water- EPA 100.2 Dust- Quantitative [fibers/sq.cm)- ASTM 05755 f ! ,.. . • ,. •• .• ·l f-:1 ~==::-il-----___...
8 ~5D(z.,
9 ~2-
- %JZ....
Page of "2.
SATURDAY SAMPLE DELIVERY - CALL TO SCHEDULE • Use this address for Saturday Delivery only: 4220 N. Santa Fe Ave., Oklahoma City, OK 73105-8517 • Mark Package "Hold for Saturday Pickup"
23
24
25
26
29
30
I..ADuRATORIES www.QuanTEM.com
ASBESTOS CHAIN OF CUSTODY 2033 Heritage Park Drive, Oklahoma City, OK 73120-7502 (800) 822-1650 • (405) 755-7272 • Fax: (405) 755-2058
LEGAL DoCUMENT .- PLEASE PRINT LEGIBLY
Page 2 of ~
SATURDAY SAMPLE DELIVERY- CALL TO SCHEDULE • Use this address for Saturday Delivery only: 4220 N. Santa Fe Ave., Oklahoma City, OK 73105-8517 • Mark Pacbge "Hold for Saturday Pickup"
1 Family Dwelling Asbestos Inspection W:/Word/HMG/13 Projects/13-2000-068.5012
5012 West Medford Avenue June 19, 2013
Milwaukee, Wisconsin HMG Project # 13-2000-068.5012
Contract # 360-13-0745
11
IX. HMG CERTIFICATION
ASBESTOS INSPECTION REPORT Job Site:
2 Family Dwelling 3731 West Stark Street Milwaukee, Wisconsin
For:
City of Milwaukee Department ofNeighborhood Services
Attn: Marge Piwaron 841 North Broadway 151 Floor
Milwaukee, Wisconsin 53202-3613
HMG Report No.: 13-2000-068.3731 Contract No.: 360-13-0745
Prepared by:
HARENDA MANAGEMENT GROUP P. 0. Box 511305
New Berlin, Wisconsin 53151-2105
May 2013
P.O. Box 5 11305 · New Berlin, Wisconsin 53 15 1-2 105 · (414) 383-4800 · (4 14) 383-4805
TABLE OF CONTENTS
I. Introduction ................... ...... ........... ...... .. ... ... .. ......... .... ............................................. 2
II. Building Survey .. .. ... ... ........ ..... ........... .... .................. ..... ...... ...... ... .... ............... ... ... .. 2
III. The Laboratory ..... ............ .. ... ...... .......... ......... .. ........................ .... ........ .. ............ ...... 2 A. Method of Analysis
IV. Findings and Observations ................................. ....... .. .................... ........................ .3
V. Exclusions ...... ..... ........ .. ... .... .. ..... ... ..... .......... ... .... .................... ........................... .... . 6
VI. Limitations ............ ........ ... ..... ..... ............ ... ....................... ... ............. ......... ........ ....... 6
VII. Pre-Demolition Environmental Checklist. .... ... ...... ... ......... . ... . ......... .. ..... . 7
VIII. Laboratory Results ................... .. .. .... .... ..... .. ... ..................... .... .. ........ ... ............ .... .. 11
IX. HMG Certifications ...... ....... .. .... ... ......................................................................... 12
2 f amily Dwelling Asbestos Inspecrion 373 1 West Stark Street Milwaukee. Wisconsin Contract # 360·1l·0745
W./Word/HMG/13 Projects/13-2000-068 3731 May 7. 2013
HMG Project# 13·2000-068
I. INTRODUCTION
Harenda Management Group (HMO) was retained by the City of Milwaukee Department of Neighborhood Services to conduct an inspection for possible asbestos containing materials in the dwelling at 373 1 West Stark Street, Milwaukee, Wisconsin.
The inspection included plaster, ceiling tile, linoleum, blown in insulation, window glazing compound, duct wrap, ceramic floor tile, transite, paper insulation, tar paper, drywall/joint compound, texture and flue packing to determine if asbestos containing materials were present within the space as required by US EPA NESHAP regulation 40 CFR 61 Subpart M
II. BUILDING SURVEY
Marge Piwaron, of the City of Milwaukee Department ofNeighborhood Services, authorized HMO to conduct a building survey and to analyze samples taken during the inspection.
On April23, 2013, HMG conducted an asbestos inspection of a two family dwelling scheduled for mechanical demolition, located at 3731 West Stark Street, Milwaukee, Wisconsin. The inspection was conducted by Jazmin Spears, Wisconsin License No. All -111055.
The inspection was comprised of three elements:
1. A visual determination as to the extent of suspect materials within the building.
2. Sampling and documentation of observable suspect materials. Category I nonfriable materials were assumed to be asbestos containing and not sampled.
3. Quantification of observable positive materials existing within the spaces.
The results of the survey integrated with the Polarized Light Microscopy with Dispersion Staining (PLM/DS) analysis of bulk samples taken are outl ined in this document. If you have any questions please contact HMO at (414) 383-4800.
III. THE LABORATORY
A. METHOD OF ANALYSIS
Analysis is performed by using the bulk samples for visual observation and slide preparation(s) for microscopical examination and identification. The slides are analyzed for asbestos ( chrysotile, amosite, crodcidolite, anthophyllite, and actinolite/ tremolite ), fibrous non asbestos constituents (mineral wool, paper, etc.), and nonfibrous constituents. Asbestos is identified by refractive indices (obtained by using dispersion staining),
2 Family Dwelling Asbestos lnspect10n 373 I West Srark Srreer ~·1ilwaukee, Wisconsin Conrracr # 360- 13-0745
2 W /Word/HMG/ 13 Projecrs/13-2000-068 3731 May 7. 2013
HMG Projecr il 13-2000-068
morphology, color, pleochroism, birefringence, extinction characteristics, and signs of elongation. The same characteristics are used to identify the non asbestos constituents. The microscopist visually estimates relative amounts of each constituent using a stereoscope if necessary. The test results are based on a visual determination of relative volume of the bulk sample components. The results are valid only for the item tested. Current US EPA NESHAP regulations state asbestos materials means material containing more than 1% asbestos as determined using the method specified in Appendix E, Subpart E, 40 CFR Part 763 Section I, Polarized Light Microscopy. Refer to 29 CFR 1926.1101 (Construction) and 29 CFR 1910.1001 (General Industry) for specific OSHA requirements.
IV. FINDINGS AND OBSERVATIONS
The materials identified as suspect asbestos containing materials (ACM) plaster, ceiling tile, linoleum, blown in insulation, window glazing compound, duct wrap, ceramic floor tile, transite, paper insulation, tar paper, drywall/joint compound, texture and flue packing. These materials were sampled and the following results were noted:
Location and Description Results Approximate Homogeneous Quantity Code
IAa I 51 floor - front room - east wall - white plaster Negative N/A SPI skim coat
lAb I 51 floor - front room - east wall - white plaster
IBa
IBb
! Ca
ICb
2Aa
2Ab
2Ba 2Bb 2Ca
2Cb
3Aa 3Ab 4A SA 6A 7 8
base coat I 51 floor - kitchen - west wall - white plaster skim coat I 51 floor - kitchen - west wall - white plaster base coat I 51 floor - west bedroom - south wall - white plaster skim coat I ' 1 floor - west bedroom - south wall - white plaster base coat 2nd floor - north bedroom - plaster skim coat no. 2 2nd floor - north bedroom - plaster base coat no. 2 2na floor - hallway - plaster skim coat no. 2 2nd floor - hallway - plaster base coat no. 2 2nd floor - north west bedroom- west wall -plaster skim coat no. 2 2nd floor - north west bedroom - west wall -plaster base coat no. 2 Attic stairwell -south wall - plaster skim coat Attic stairwell - south wall - plaster base coat I 51 floor - front room - ceiling tile I 51 floor - front entrance - ceiling tile I 51 floor - east bedroom - ceiling tile I ' 1 floor - hallway - tan linoleum I 51 floor - bathroom - beneath sink - yellow linoleum
2 Family Dwelling Asbestos Inspection 3731 West Stark Street Milwaukee. Wisconsin
3
Contract # J60-13-074S
Negative
Negative
Negative
Negative
Negative
Negative
Negative
Negative Negative Negative
Negative
Negative Negative Negative Negative Negative Negative Negative
N/A SPI
N/A SPI
N/A SPI
N/A SPI
NIA SPI
NIA SPI #2
N/A SPI #2
NIA SPI #2 NIA SPI #2 NIA SPJ #2
NIA SPI #2
NIA SP I N/A SPJ N/A MSCT N/A MSCT NIA MSCT N/A MFLt N/A MFLI
W /Word/HMG/13 ProjectS/13-2000-068 3731 May 7, 2013
H.'-'IG Project # 13-2000-068
Sample# Location and Description
9 I 51 floor - north bedroom - inside south wall -blown in insulation
10 2na floor - north bedroom - inside east wall -blown in insulation
lOA Attic stairwell - inside west wall - blown in insulation
I lA Basement - south window- window glazing compound
liB I 51 floor - kitchen - east window - window glazing compound
IIC 2na floor - east bedroom - west window -window g lazing compound
12A I 51 floor - kitchen - duct wrap
12B I 51 floor - living room - duct on south wall - duct wrap
12C 2na floor- bathroom - duct on east wall - duct wrap
13a I 51 floor - kitchen - ceramic floor tile 13b I 51 floor- kitchen -ceramic floor tile grout 14A Exterior - south side of house- transite s iding
14B Exterior - north side of house - transite siding
14C Exterior- west side of house- transite siding
ISA Exterior - south side, beneath transite siding -silver paper insulation
ISB Exterior - west side, beneath transite siding -silver paper insulation
ISC Exterior - north side, beneath transite siding -silver paper insulation
16A Exterior- north side, beneath transite siding and paper insulation - tar paper
17Aa Garage - interior east wall - brown paper insulation
17Ab Garage - interior east wall - brown insulation 178 Garage - interior south wall - brown paper
insulation 17C Garage - interior west wall - brown paper
insulation 18Aa 151 floor - kitchen - north wall - drywall 18Ab I 51 floor - kitchen- north wall - joint compound 188 Attic - north room - ceiling - drywall 18C 19A Rear stairwell - on steps and landings - gray
linoleum 20A Rear stairwell - on 6m step from top - cream/gray
linoleum
2 Family Dwelling Asbestos lnspection 3731 West Stark S1reet
4 Milwaukee, Wisconsin Con1ract # 360·13-0745
Results
Negative
Negative
Negative
Negative
Negative
Negative
Positive 75% Chrysotile
Positive 75% Chrysotile
Positive 75% Chrysotile Negative Negative
Positive 20% Chrysotile
Positive 20% Chrysotile
Positive 20% Chrysotile Negative
Negative
Negative
Negative
Negative
Negative Negative
Negative
Negative Negative Negative Negative Negative
Negative
Approximate Homogeneous Qua~tity Code
N/A MBI
N/A MBI
N/A MBI
N/A MPG
N/A MPG
N/A MPG
55 Sq. Ft. TDW
Reference TDW #12A
Reference TDW #12A N/A MCTM N/A MCTM
1 ,800 Sq. Ft. MTP
Reference MTP #14A
Reference MTP #14A N/A MPis
NIA MP!s
N/A MPis
NIA MPT
N/A MP!n
N/A MP!n NIA MP!n
NIA MP!n
N/A MOW N/A MOW NIA MOW NIA MOW NIA MFLy
NIA MFLcy
W./Word/HMG/13 Projeots/13·2000·068 3731 May7, 20 13
HMG Project # 13·2000-068
Sample# Locaiion and Description Results Approximate Homogeneous
21A 2"0 floor- north west bedroom - top layer -brown linoleum
22A 2"0 floor - north west bedroom - bottom layer -brown/black linoleum
23A 2M floor - north west bedroom - scrap on floor -white linoleum
24A Attic - west room - ceiling- texture 248 Attic - west room - south wall - texture 24C 2M floor - rear stairwell - east wall - texture 25A 2"0 floor - front stairwell -on steps - tan/brown
linoleum 26A Basement stairwell - on steps - brown/gray
linoleum 27A Basement - on chimney - flue packing
Notes: N/A = Not Applicable Sq. Ft. = Square Feet
Negative
Negative
Negative
Negative Negative Negative Negative
Negative
Negative
Assumed Category I Non-Friable Asbestos Containing Material:
Quantity Code
NIA MFLn
NIA MFLnk I
N/A MFLw I
NIA STX NIA STX NIA STX N/A MFLtn '
NIA MFLny '
N/A TFP
Floor Level Location Description Approximate Quantity
Roof Dwelling Asphalt Shingles & Flashing 750 Sq. Ft. Siding Dwelling (East & West Sides Only) Asphalt Shingle Siding I ,800 Sq. Ft. Roof Garage Asphalt Shingles & Flashing 400Sq. Ft.
1st Hallway
Homogeneous Material Codes SPI Plaster SPI #2 Plaster No.2 MSCT Ceiling Tile MFLt Tan Linoleum MFLI Yellow Linoleum
Blown In Insulation MBI MPG TDW MCTM MTP MPis MPT MPin MDW MFLy MFLcy MFLn MFLnk MFLw STX MFLtn MFLny TFP
Window Glazing Compound Duct Wrap
2 Family Dwelling Asbestos lnspection 373 I West Stark Street Milwaukee, Wisconsin Contract # 360· I 3·0745
Ceramic Floor Tile & Grout Transite Siding Silver Paper Insulation Tar Paper Brown Paper Insulation DrywalVJoint Compound Gray Linoleum Cream/Gray Linoleum Brown Linoleum Brown/Black Linoleum White Linoleum Texture Tan/Brown Linoleum Brown/Gray Linoleum Flue Packing
5
Floor Tile & Mastic 30 Sq. Ft.
W:/Wo rd/HMGIJ 3 Projects/13·2000·068 3731 May 7. 2013
HMG Project# 13·2000·068
Note#l: Category 1- Non-Friable Asbestos Containing Materials may become friable during mechanical demolition activities or maybe considered friable prior to demolition activities due to its current condition.
Note#2: If additional materials are discovered during demolition that are not listed above they are to be assumed to be asbestos containing.
Note#3: A copy of this report should be transmitted to the demolition contractor.
Note#4: Additional duct wrap may be discovered between structural walls and ceilings. Exploratory demolition is required for exact quantity.
Note#S: Estimated cost for friable asbestos removal ..
V. EXCLUSIONS
Roof visible only from ground. No visible or accessible areas or material were excluded from this scope of work.
HMO is not and shall not represent the building owner as its agent or representative for the purpose ofthe US EPA/NESHAP andJor the WDNR/NR447 regulations, as owner/operator.
This report represents the condition of the building and its visible/accessible suspect asbestos containing materials at the date and the times of the onsite inspection. Hidden materials or those materials that could be present at the point of inspection, over and above those stated in the inspection report, are the responsibility of the building owner and the demolition contractor.
VI. LIMITATIONS
The care and skill given to our procedures insures the most reliable test results possible. HMG utilizes Quantem Laboratories for our Polarized Light Microscopy, unless otherwise specified by the client. The findings and conclusions of HMG represent our professional opinions extrapolated from limited data. Significant limited data is gathered during the course of the preliminary asbestos specific site assessment. No other warranty is expressed or implied. Prior to any abatement or renovation activities, it is recommended that HMO be provided the opportunity to review such plans in order that the inspection and assessments contained herein are properly interpreted and implemented.
This report and the information contained herein are prepared for the sole and exclusive use and possession of the City of Milwaukee Department of Neighborhood Services. No other person or entity may rely on this report or any information contained herein. Any dissemination of the Report or any information contained herein is strictly prohibited without prior written authorization from Harenda Management Group.
2 Family Dwelling Asbes1os Inspection 373 I West Stark Street Milwaukee, Wisconsin Contract # 360-13-0745
6 W /Word/HMG/ 13 Projeetslll-2000-068.373 I May 7, 2013
HMG Project # 13-2000-068
VII.
2 Family Dwelling Asbestos Inspection 373 I WeSI Stark Street Milwaukee, Wisconsin Contract # 360- 13-0745
PRE-DEMOLITION ENVIRONMENTAL CHECKLIST
7 W /Word!HMG/13 ProJects/13-2000-068 3731 May 7, 2013
HMG Project # I 3-2000-068
This guide lists materials and products commonly found in buildings with examples. It is not intended as a substitute for reading the rules and statutes and making your own independent determination of their applicability to your demolition project. These examples presented here do not represent an exhaustive listing oftypes of materials that may be required to be removed from the building prior to demolition.
ASBESTOS Persons conducting inspections for asbestos must hold a valid asbestos inspector certification card issued by the State of Wisconsin, Dept. of Health & Family Services. Please follow the Asbestos Inspection and Sampling Protocol for Buildings to be Demolished or Renovated.
CFCs and HALONS Equipment that may contain CFCs and Halons:
Nl A Air Conditioners (roof top, room, and central)
Nl A Dehumidifiers
N/ A Heat Pumps
N/ A Refrigerators, Freezers, Chillers
N/A Vending Machines, Food Display Cases
NIA Walk-in Coolers
NIA Water Fountains (bubblers)
NIA Fire Extinguishers (both portable and installed HALON suppression systems)
Nl A Water Coolers
LEAD Lead or Lead Based Paint (LBP) is common in many older buildings. When recycling construction and demolition debris, be aware that wood containing lead paint may not be chipped and spread for landscaping. State law also prohibits the sale or transfer of any fixture or other object containing LBP that might be placed upon any surface of a dwelling, which is ordinarily accessible to children.
2 Family Dwelling Asbestos Inspection 3 731 West Stark Street Milwaukee, Wisconsin Contract# 360-13-0745
8 IV /Word/HMG/ 13 Projects/ll-2000-068 3731 May 7, 2013
HMG Project # 13-2000-068
MERCURY Products that may contain mercury:
LIGHTING _ 1_
NIA
Fluorescent Lights - I st Floor Hall
High Intensity Discharge -Metal Halide -High Pressure Sodium -Mercury Vapor
NIA Neon
NIA Switches for lighting using mercury relays -Look for any control associated with exterior or automated lighting systems such as "Silent" wall switches.
HVAC Check thermostats and any control associated with air handling units for switches containing mercury.
HEATING, VENTILATING AND AIR CONDITIONING SYSTEMS
NIA Old Thermostats
Nl A Aquastats
Nl A Firestats
Nl A Manometers
Nl A Thermometers
BOILERS, FURNACES, HEATERS AND TANKS - 2 Furnaces & 2 Hot Water Heaters in the Basement
Nl A Mercury Flame Sensors by pilot lights
Nl A Manometers, Thermometers, Gauges
Nl A Pressure-trol
N/ A Float or Level Controls
Nl A Space Heaters
2 Family Dwelling Asbestos Inspection J 731 West Stark Street Milwaukee, Wisconsin Contract # 360· 13·0745
9 W:/Word/HMG/13 Projects/13-2000-068 373 1 May 7, 20 13
HMO Project# IJ-2000-068
ELECTRICAL SYSTEMS
N/ A Load Meters and Supply Relays
N/ A Phase Splitters
N/ A Microwave Relays
N/ A Mercury Displacement Relays
PCBs For electrical devices manufactured prior to 1987, it is safe to assume that they contain PCBs and should be managed accordingly. Most equipment manufactured after this time will say "PCB Free". The following is a list of areas in a building were PCBs may be found:
Nl A Transformers
N/A Capacitors (appliances, electronic equipment)
N/A Heat Transfer Equipment
N/ A Light Ballasts
N/A Specialty Paints (such as for swimming pools or other industrial applications)
N/A Sumps or Oil Traps (in maintenance and industrial facilities)
OTHER ENVIRONMENTAL ISSUES
N/A Hazardous Waste
2 Oil Tanks - Basement
N/A Well Abandonment
N/A Junk Auto Tires
N/A Junk Vehicles
* * 2 Gas Meters in the Basement * * 1 Quart of Motor Oil in the Garage
2 Family Dwelhng Asbestos Inspection 3 731 WeSI Stark Street Milwaukee, Wisconsin Contract # 360·13·0745
10 W ./Wordltt\1G/13 Proj<cts/13-2000-068 3731 May 7. 2013
HMG Project # 13-2000·068
2 Family Dwelling Asbestos Inspection 3731 West Stark Street Milwaukee, Wisconsin Contract # 360-13-0745
VIII. LABORATORY RESULTS
II WJWord/HMG/ 13 Projects/13-2000-068 373 1 May7, 2013
HMG Project# 13-2000-068
®
2033 Heritage Park Drive I Oklahoma City, OK 73120/ (405) 755-7272 / Fax (405) 755-2058
Polarized Light Microscopy Asbestos Analysis Report
QuanTEM Lab No. 221036
Account Number: B929 Client: Harenda Management Group
Jolene Harenda
Date Received: 05/0312013 Received By: Date Analyzed:
Analyzed By: Methodology:
QuanTEM SampleiD
001
OOla
002
002a
003
003a
004
Barbara Holder 05/06/2013
Gayle Ooten EPA/600/R.-93/116
Client SampleiD
lA
IS
IC
2A
Composition
Layered
Homogeneous
Layered
Layered
Layered
Layered
Layered
Project: DNS
P.O. Box 511305 NewBerlin, WI5315l-2105
Project Location: Milwaukee, WI Project Number: 13-2000-068.3731
Color/ Description
White
Skim Coat
White
Plaster
White
Skim Coat
White
Plaster
White
Skim Coat
White
Plaster
'\Vhite
Skim Coat
Asbestos (%)
Asbestos Not Present
Asbestos Not Present
Asbestos Not Present
Asbestos Not Present
Asbestos Not Present
Asbestos Not Present
Asbestos Not Present
Non-Asbestos Fiber(%)
NA
NA
NA
NA
NA
NA
NA
Unless otherwise noted, upon receipt the condition of the sample was acceptable for analysis.
Non Fibrous
Quartz CaC03 Paint
Gypsum Perlite
Quartz CaC03 Paint
Gypsum Perlite
Quartz CaC03 Paint
Gypsum Perlite
Quanz CaC03 Paint
Quan TEM is a NV LAP accredited TEM and PLM laboratory {Lab Code: 10 l959·0). This report relates only to the specific items tested. NVLAP accreditation applies only to analysis·performed utilizing EPN6001M4-82-020 and EPA/600/R-93/116 methods. This report may not be used to claim product endorsement by NVLAP or any
other agency of the US Government. This report may not be reproduced except in full, \\ithout the written approval of the laboratory.
Page 1 of 9
2033 Heritage Park Drive I Oklahoma City, OK 73120 I (405) 755-7272/ Fax (405) 755-2058
Polarized Light Microscopy Asbestos. Analysis Report
QuanTEM Lab No. 22l036 Account Number: B929
Client: Harenda Management Group Jolene Harenda
Date Received:
Received By:
Date Analyzed: Analyzed By: Methodology:
QuanTEM Sample ID
05/03/2013
Barbara Holder
05/06/2013 Gayle Ooten
EPA/600/R-93/116
Client SamplelD Composition
---------
004a Layered
005 2B Layered
005a Layered
006 2C Layered
006a Layered
007 JA Layered
007a Layered
P.O. Box 511305 New Berlin, WI 53151-2105
Project: DNS Proje~t L{)cation: Milwaukee, WI ·
Proj~ct Number: 13-2000-068.3731
Color I Non-Asbestos Description Asbestos (%) Fiber(%)
White Asbestos Not Present NA
Plaster
White Asbestos Not Present NA
Skim Coat
Tan Asbestos Not Present NA
Plaster
White Asbestos Not Present NA
Skim Coat
Tan Asbestos Not Present NA
Plaster
White Asb'estos Not Present NA
Skim Coat
Tan Asbestos Not Present NA
Plaster
t:nless otherwise noted, upon receipt the condition of the sample was acceptable for analysis.
Non Fibrous
Gypsum Perlite
CaC03 Paint
Quartz CaC03
CaC03 Paint
Quartz CaC03
CaC03 Paint
Quartz CaC03
QuanTE~ is a NVlAP accredited TEM and PLM laboratory (lab Code: 101959-0). This report relates only to the specific items tested. NVLAP accreditation applies only to analysis performed utilizing EPA/600/M4-82,020 and EPA/600/R-93/ 116 methods. This report may not be used to claim product endorsement by NVLAP or any
other agency of the US Government. Tbis report may !lot be reproduced except in full, without the written approval of the laboratory.
Page 2 of9
2033 Heritage Park Drive I Oklahoma City, OK 73120 I (405) 755-7272/ Fax (405) 755-2058
Polarized Light Microscopy Asbestos Analysis Report
QuanTEM Lab No. 221036 . Client: Harenda Management Group Jolene Harenda Account Number: B929
Date Received: Received By:
Date Analyzed: Analyzed By:
Methodology:
QuanTEM SampleiD
008
009
010
Oil
Of2
013
014
05/03/2013
Barbara Holder 05/06/2013
Gayle Ooten
EPA/600/R-93/116
Client SamplciD
4A
5A
6A
7
8
9
10
Composition
Homogeneous
Homogeneous
Homogeneous
Homogeneous
Homogeneous
Homogeneous
Homogeneous
P.O. Box 511305 New Berlin, WI 53151-2L05
Project: DNS
Project Location: Milwaukee, WI
Project Number: 13-2000-068.3731
Color I Description
White
Ceiling Tile
White
Ceiling Tile
White
<;eiling Tile
Beige
Linoleum
Yellow Floor Tile
Gray
Insulation
.Gray
Insulation
Asbestos (%)
Asbestos Not Present
Asbestos Not Present
Asbestos Not Present
Asbestos Not Present
Asbestos Not Present
Asbestos Not Present
Asbestos Not Present
Non-Asbestos Non Fibrous Fiber(%)
Cellulose 80 Paint
Cellulose 80 Paint
Cellulose . 80 Paint
Cellulose 25 Tar
NA
Cellulose I 00
Cellulose I 00
Vinyl CaCQ3
Unless otherwise noted, upon receipt the coadition of the sample was acceptable for analysis.
Quan1EM is a NVlAP accredited TEM and PLM laboratory (Lab Code: 101959-0). This report relates only to the specific items tested. NVLAP accreditation applies only to analysis performed utilizing EP • .tV600/lvf4-82-020 and EP N600/R-93/ll6 methods. This report may not be used to claim product endorsement by ~1.AP or any
other agency of the US Government. This report may not be reproduced except in full, without the written approval of the laboratory.
Page 3 of9
2033 Heritage Part< Drive I Oklahoma City, OK 73120./ (405) 755-7272/ Fax (405) 755-2058
Polarized Light Microscopy Asbestos Analysis Report
QuanTEM Lab No. 221036 Client: Harenda Management Group Jolene Harenda Account Number: 8929 P.O. Box 511305
Date Received: 05/03/2013
Barbara Holder
05/06/2013
New Berlin. WI 53151-2105 Received By:
Date Analyzed:
Analyzed By:
Methodology:
QuanTEM Sample ID
015
016
017
018
019
020
021
Gayle Ooten
EPA/600/R-931116
Client Sample ID
lOA
llA
liB
llC
12A
12B
12C
Composition
Homogeneous
Homogeneous
Homogeneous
Homogeneous
Homogeneous
Homogeneous
Homogeneous
Project: DNS Project Location: Milwaukee, WI
Project Number: 13-2000-068.3731
Color I Descriptiob
Gray
£nsulation
White
Window Glazing
White
Window Glazing
White
Window Glazing
Gray
Insulation
Gray
Insulation
Gray
Insulation
Asbestos(%)
Asbestos Not Present
Asbestos Not Present
Asbestos Not Present
Asbestos Not Present
Asbestps Present Chrysotile 75
Asbestos Present Chrysotile 75
Asbestos Presen~ Chrysotile 75
Unless otherwise noted, upon receipt the condition of the sample was acceptable for anal}-sis.
Non-Asbestos Fiber(%)
Cellulose
NA
NA
NA
Cellulose
Cellulose
Cellulose
Non Fibrous
100
CaC03
CaC03
CaC03
20 Binder
20 Binder
20 Binder
Quan TEM is a NVlAP accredited TEM and PLM laboratory (Lab Code: 10 1959-0). This report relates only to the specific items tested. NVlAP accreditation applies only to analysis perfonned utilizing EPA/600/M4-82-020 and EPA/600/R-93/116 methods. This report may not be used to claim product endo!SCillent by NVLAP or any
other agency of the US Government. This report may not be reproduced except in full, without the written approval of the laboratory.
Page 4 of9
2033 Heritage Park Drive I Oklahoma City, OK 73120 I (405) 755-7272 1 Fax (405} 755-2058
Polarized Light Microscopy Asbestos Analysis Report
QuanTEM Lab No. 221036
Account Number: B929
Client: Harenda Management Group Jolene Harenda
Date Received:
Received By: Date Analyzed:
Analyzed By: Methodology:
QuanTEM SampleiD
022
022a
023
024
025
026
027
05/03/2013
Barbara Holder
05/06/2013
Gayle Ooten EPA/600/R-93/116
Client Sample ill
13
14A
14B
14C
15A
158
Composition
Layered
Layered
Homogeneous
Homogeneous
Homogeneous
Homogeneous
Homogeneous
P.O. Box 511305 New Berlin, WI 53151-2105
Project: DNS
Project Location: Milwaukee, WI
Project Number: 13-2000-068.3731
Color I Description
· White
Ceramic Tile
White
Grout
Gray
Transite
Gray
Transite
Gray
Transite
Silver/Black
Wrap
Silver/Black
Wrap
Asbestos(%)
Asbestos Not Present
Asbestos Not Present
Asbestos Present Cluysotile 20
Asbestos Present Chrysotile 20
Asbestos Present Cbrysotile 20
Asbestos Not Present
Asbestos Not Present
Non-Asbestos Fiber(%)
NA
NA
NA
NA
~A
Cellulose
Cellulose
40
40
Unless otherwise noted, upon receipt the condition of the sample was acceptable for analysis.
Non Fibrous
Clay
Quartz CaC03
CaC03
CaC03
CaC03
Tar Foil
Tar Foil
QuanTEM is a NVLAP accredited TEM and PLM laboratory (Lab Code: 101959-0). This report relates only to the specific items tested. NVI.AP accreditation applies only to analysis performed utilizing EPA/600/M4-82-020·and EPA/600/R-93/116 methods. This report may not be used to claim product endorsement by NVLAP or any
other agency of the US Government. This report may not be reproduced except in full, ?.i thout the wrincri approval of the laboratory.
Page 5 of 9
2033 Heritage Park Drive I Oklahoma City, OK 73120 I (405) 755-7?:72/ Fax (405) 755-2058
Polarized Light Microscopy Asbestos Analysis Report
QuanTEM Lab No. 221036
Account Number: B929 Client: Haren cia Management Group
Jolene H.arenda
Date Received:
Received By:
Date Analyzed:
Analyzed By: .
Methodology:
QuanTEM SampleiD
028
029
0~0
030a
031
032
033
05/03/2013
Barbara Hol~er
05/06/2013
Gayle Ooten EPA/600~-93/116
Client SampleiD
15C
16A
17A
178
17C
18A
Composition
Homogeneous-
Homogeneous
Layered
Layered
Homogeneous
Homogeneous
Layered
P.O. Box 511305 New Berlin, Wl53151-2105
Project: DNS
Project Location: Milwaukee, WI Project Number: 13-2000-068.3731
Color / Description
Silver/Black
Wrap
Black
Tar Paper
Black/Brown
Tar Paper
Brown
Insulation
Black/Brown
TarPaper
Brown/Black
Tar Paper
White
Texture
Asbestos(%)
Asbestos Not Present
Asbestos Not Present
Asbestos Not Present
Asbestos Not Present
Asbestos Not Present
Asbestos Not Present
Asbestos Not Present
Non-Asbestos Fiber(%)
Cellulose
Cellulose
Cellulose
Cellulose
Cellulose
Cellulose
~A
40
40
40
90
45
45
Unless otherwise noted, upon receipt the condition of the sample was acceptable for analysis.
Non Fibrous
Tar Foil
Tar
Tar
Binder
Tar
Tar
CaC03 Paint
QuanTEM is a NVLAP accredited TEM and PLM !~oratOry (Lab Code: 101959-0). This report relates only to the specific items tested. NVLAP a<A:reditation applies only to analysis performed utilizing EPA/600~14-82-020 and EPA/600/R-93/116 methods. This report may not be used to claim product endorsement by NVLAP or any
other agency of the US Government This report m~y not be reproduced except in full, without the written approval of the laboratory.
Page 6 of 9
®
2033 Heritage Pai'X Drive i Oklahoma City, OK 73120 I (405) 755-7272/ Fa.IC (405) 755-2058
Polarized Light Microscopy Asbestos Analysis Report
QuanTEM Lab No. 221036
Account Number: B929
Date Received: 05/03/2013
Received By:
Date Analyzed: Analyzed By: Methodology:
QuanTEM SampleiD
033a
034
035
036
037
038
039
Barbara Holder 05/06/2013
Gayle Ooten EPA/600/R-93/116
Client Sample 1D
18B
18C
19A
20A
21A
22A
Composition
Layered
Homogeneous
Homogeneous
Homogeneous
Homogeneous
Homogeneous
Homogeneous
Project: DNS
Client: Harenda Management Group Jolene Harenda P.O. Box 511305 New Berlin, WI 53151-2105
Project Location: Milwaukee, WI
Project Number: 13-2000-068.3731
Color/ Description
White
Sheetrock
White
Sheetrock
White
Sheetrock
Tan
Backing
Tan
Backing
Bro"'n
Sheet Vinyl
Tan
Linoleum
Asbestos (%)
Asbestos Not Present
Asbestos Not Present
. .<\sbestos Not Present
Asbestos Not Present
Asbestos Not Present
Asbestos "Not Present
Asbestos Not Present
Non-Asbestos Fiber(%)
Non Fibrous
Cellulose 20 Gypsum
Cellulose 15 Gypsum
Cellulose 20 Gypsum
Cellulose 40 Binder Synthetic 40
Cellulose 80 Binder
Cellulose 20 Vinyl
Cellulose 25 Tar
Unless otherwise noted, upon receipt the condition of tile sample was acceptable for analysis.
QuanTEM is a NVL6J> accredited TEM and PLM laboratory (Lab Code: 101959-0). This report relates only to the specific items tested. NVLAP accreditation applies only to analysis performed utilizing EPA/600/M4-82-020 and EPA/600/R-93/1 16 methods. This report may not be used to claim product endorsement by NVLAP or any
other agency of the US Government This report may not be reproduced except in full, without the wrinen approval of the laboratory.
Page7of9
.,~....... M® ~I».'.:'~L .I ~LABORAtORIES
2033 Heritage Park Diive I Oklahoma City, OK 73120 I (405) 755-7272/ Fax (405) 755-2058
Polarized Light Microscopy Asbestos Analysis Report
QuanTEM Lab No. 221036 Client: Harenda Management Group Jolene Harenda Account Number: B929
Date Received:
Received By:
Date Analyzed: Analyzed By:
Methodology:
QuanTEM SampleiD
05/03/2013
Barbara Holder 05/06/2013 Gayle Ooten
EPAJ600nt-93/116
Client Sample ID Composition
P.O. Box 511305 New Berlin, WI 53151-2105
Project: DNS Project Location: Milwaukee, WI Project Number: 13-2000-068.3731
Color/ Description Asbestos (%)
Non-Asbestos Fiber(%)
Non Fibrous
-- ·-··-··- .. ........ ····· -· -·- ··---- . -·----------- - --
040 23A Homogeneous Cream Asbestos Not Present Cellulose 25 Vinyl
Sheet Vinyl
041 24A Homogeneous White Asbestos Not Present NA CaC03
Ceiling. Texture Paint
042 24B Homogeneous White Asbestos Not Present NA CaC03
Ceiling Texture Paint
043 24C Homogeneous White Asbestos Not Present NA CaC03
Ceiling Texture Paint
044 25A Homogeneous Tan Asbestos Not Present Cellulose 25 Tar
Linoleum
045 26A Homogeneous Beige Asbestos Not Present Cellulose 10 CaC03
Linoleum Synthetic 10
~
046 27A Homogeneous Gray Asbestos l"ot Present NA Quartz Mortar CaC03
Unless otherwise noted, upon receipt the condition of the swnple was acceptable for analysis.
QuanTEM is a NVLAP accredited TEM and PLM laboratory (lab Code: 101959·0). Tnis report relates only to the specific items tested. NVLAP accreditation applies only to analysis performed utilizing EPN600/M4-82-<J20 and EPN600/R-931116 methods. This report may not be used to claim producr endoJSement byNVLAP or any
other agency oftJ_te US Govemment. This report may not be reproduced except in full, without the writm~ approval of the laboratory.
Page 8 of9
... lUI® ••• LABORATORIES
2033 Heritage Paik Drive I Oklahoma City, OK 73120 I {405) 755-7272/ Fax (405) 755-2058
Polarized Light Microscopy Asbestos Analysis Report
QuanTEMLab No. 221036 Client: Harenda Management Group Jolene Harenda Accowtt Number: B929
Date Received: Received By:
Date Analyzed:
Analyzed By:
Methodology:
QuanTEM Sample ID
05/03/2013
Barbara Holder
05/0612013
Gayle Ooten
EPA/600/R-93/1 16
Client SampleiD Composition
P.O. Box 511305 New Berlin, WI 53151-2105
Project: DNS
Project Location: Milwaukee, WI
Project Nwnber: 13-2000-068.3731
Color/ Description Asbestos (%)
Non-Asbestos Fiber(%)
--··---------··-----·---·---.,.---
51612013 Date of Report
Unless otherwise noted, upon receipt the condition of the sample was acceptable tbr analysis.
Non Fibrous
QuanTE!\{ is a NY LAP accredited TEM and PLM laboratory (Lab Code: 101959..()). This report relates only to the specific items tested. NVLAP accreditation applies only to analysis performed utilizing EPA/6001M4-82-020 and EPA/6001R-93/ll6 methods. This repon may not be used to claim product endorsement by NVLAP or any
other agency of the US Government. This report may not be reproduced except in full, without the written approval of the laboratory.
Page 9of9
RATORIES www.QuanTEM.com
ASBESTOS CH.AIN OF CUSTODY 2033 Heritage Park Drive, Oklahoma City, OK 73120· 7502 (800) 822·1650 • (405) 7$5-7272 • Fax: (405) 755-2058
LEGAL DOCUMENT!'" PLEASE PRINT LEGIBLY
Cell Phone: ProJectLocation: Milwaukee, WI - ---------------
13-2000·068.3731 . ~ . ~·. -·- E-mail: djacob::[email protected] 11 .~•-oi_ect_ID_: _ ______ _
Bulk· Quantitative [weight%)· Chatfield
Dust- Quantitative (fibers/sq.cm)· ASTM 05755
I •
Page 1 of
Other .email
SATURDAY SAMPLE DELIVERY· CALL TO SCHEDULE • Use this address for Saturday Delivery only: 4220 N. Santa Fe Ave., Oklahoma City, OK 73105-8517 • Mark Package "Hold for Saturday Pkkup"
LABORATORIES www.QuanTEM.com
ASBESTOS CHAIN OF CUSTODY 2033 Heritage Park Drive, Oklahoma City, OK 73120-7502 (800) 822-1650 • (405) 755·7272 • Fax: (405) 755-2058
'
LEGAL DoCUMENT·- PLEASE PRINT LEGIBLY
Page 2 of _ _
SATURDAY SAMPLE DELIVERY- CALL TO SCHEDULE • Use this address for Saturday Delivery only: 4220 N. Santa Fe Ave., Oklahoma City, OK 73105-8517 • Mark Package "Hold for Saturday Pickup"
50
ASBESTOS CHAIN OF CUSTODY 2033 Heritage Park Drive, Oklahoma City, OK 73120-7502 (800} 822-1650 • (405) 755-7272 • Fax: (405) 755-2058
\
LEGAL DOCUMENT • PLEASE PRINT LEGIBLY
Page 3 of
SATURDAY SAMPLE DELIVERY - CALL TO SCHEDULE • Use thisaddress for Saturday Delivery only: 4220 N. Santa Fe Ave., Oklahoma City, OK 73105-8517 • Mark Package "Hold for Saturday Pickup"
2 Family Dwelling Asbestos lnspecrion 3731 Wes1 Stark Street Milwaukee, Wisconsin Contract # 360-13-0745
IX. HMG CERTIFICATION
12 W /Word/HMG/ 13 Projects/13-2000-068373 1 May 7, 20 1l
HMG Project# I J-2000-068
Scott Walker Governor
Kitty Rhoades Secretary
May 1, 2013
JAZMIN K C SPEARS
1237 W BRUCE ST
MILWAUKEE WI 53204-1218
State of Wisconsin Department of Health Services
DIVISION OF PUBLIC HEALTH .
ID# AII-111055
1 WEST WILSON STREET
P 0 BOX2659 MADISON WI 53701-2659
Telephone: 608 266-1251 FAX: 608 267-2832 TIY: 888-701-1253
dhs.wisconsln.gov
Congratulations, your new card for Wisconsin asbestos or lead certification is enclosed. Please contact our office immediately if any of the infonnation on the card is incorrect.
You must have this card with you whenever you are at a regulated asbestos or lead work site.
Renewing Your Certification You may not perfonn regulated asbestos or lead activities after the expiration date on your card.
Asbestos Disciplines: Schedule your annual asbestos refresher training 30-90 days before your training due date and submit your renewal application online or by mail at least one month before your current card expires.
Lead Disciplines: Schedule your lead refresher training up to 12 months before the training due date and submit your renewal application online or by mail at least one month before your current card expires.
Submit your renewal application by mail if paying by check or money order, or online at www.dhs.wisconsin.gov/waldo if paying by VISA or MasterCard credit or debit card.
Certified Company Mfiliation You must be affiliated with an appropriately certified Asbestos, Exterior Asbestos, Lead or LeadSafe Company by ownership, employment or contract before you may perform regulated lead or asbestos work in ·wisconsin. Contact the Asbestos and Lead Section for more information.
To Update Information and Apply Online You may make changes to your mailing address, other contact information, or your employer information by going to www.dhs.wisconsin.gov/waldo and selecting Asbestos and Lead Online Certification. You may also send changes in writing to the Asbestos and Lead Section at the address below.
Asbestos and Lead Section, Room 137 P.O. Box 2659 Madison WI 53701-2659
Phone: (608) 261-6876 Email: [email protected] In~emet: www,dhs.wisconsin.gov
ASBESTOS 1:-\SPECTOR
STATE OF WISCONSI:-i
Dc:pt. of He-<~l lh Scr.·iccs
Jazmio K C Spears
1237 W Bruce: St
Milwaukee: Wl53204-1218
198 lbs 5' 08"
I AII-111055 I Exo: 03/17/2014 10/1911974 \talc:
Training due by: 03127/2014
1237 West Bruce Street · Milwaukee, Wisconsin 53204 · (414) 383-4800 · (414) 383-4805
ASBESTOS SNIP INSPECTION REPORT
Job Site:
One Family Dwelling
3215 North 23rd
Street
Milwaukee, Wisconsin
For:
City of Milwaukee
Department of Neighborhood Services
Attn: Marge Piwaron
841 North Broadway 1st Floor
Milwaukee, Wisconsin 53202-3613
HMG Report No.: 13-2000-399.3215
Contract No.: 360-13-0745
________________________ Dean Jacobsen
Asbestos Inspector No. AII – 14370
Prepared by:
HARENDA MANAGEMENT GROUP
1237 West Bruce Street
Milwaukee, Wisconsin 53204
December 2013
1 Family Dwelling SNIP Asbestos Inspection W:/Word/HMG/13 Projects/13-2000-399.3215
3215 North 23rd Street December 23, 2013
Milwaukee, Wisconsin
Contract # 360-13-0745
1
TABLE OF CONTENTS
I. Introduction ..............................................................................................................2
II. Building Survey .......................................................................................................2
III. The Laboratory .........................................................................................................2
A. Method of Analysis
IV. Findings and Observations .......................................................................................3
V. Exclusions ................................................................................................................4
VI. Limitations ...............................................................................................................4
VII. Pre-Demolition Environmental Checklist…………………………………………6
VIII. Laboratory Results .................................................................................................10
IX. HMG Certifications ...............................................................................................11
1 Family Dwelling SNIP Asbestos Inspection W:/Word/HMG/13 Projects/13-2000-399.3215
3215 North 23rd Street December 23, 2013
Milwaukee, Wisconsin
Contract # 360-13-0745
2
I. INTRODUCTION
Harenda Management Group (HMG) was retained by the City of Milwaukee Department of
Neighborhood Services to conduct an inspection for possible asbestos containing materials in the
dwelling at 3215 North 23rd Street, Milwaukee, Wisconsin.
The inspection included plaster, texture, drywall, blown in insulation, duct paper, linoleum, flue
packing, joint compound patch, window glazing compound, and asphalt shingle siding to
determine if asbestos containing materials were present within the space as required by US EPA
NESHAP regulation 40 CFR 61 Subpart M.
II. BUILDING SURVEY
Marge Piwaron, of the City of Milwaukee Department of Neighborhood Services, authorized
HMG to conduct a building survey and to analyze samples taken during the inspection.
On December 13, 2013, HMG conducted an asbestos inspection of a one family dwelling,
scheduled for mechanical demolition, located at 3215 North 23rd Street, Milwaukee,
Wisconsin. The inspection was conducted by Dean Jacobsen, Wisconsin License No. AII –
14370.
The inspection was comprised of three elements:
1. A visual determination as to the extent of suspect materials within the building.
2. Sampling and documentation of observable suspect materials. Category I non-friable
materials were assumed to be asbestos containing and not sampled.
3. Quantification of observable positive materials existing within the spaces.
The results of the survey integrated with the Polarized Light Microscopy with Dispersion
Staining (PLM/DS) analysis of bulk samples taken are outlined in this document. If you have
any questions please contact HMG at (414) 383-4800.
III. THE LABORATORY
A. METHOD OF ANALYSIS
Analysis is performed by using the bulk samples for visual observation and slide preparation(s)
for microscopical examination and identification. The slides are analyzed for asbestos
(chrysotile, amosite, crodcidolite, anthophyllite, and actinolite/ tremolite), fibrous non asbestos
constituents (mineral wool, paper, etc.), and nonfibrous constituents. Asbestos is identified by
refractive indices (obtained by using dispersion staining), morphology, color, pleochroism,
birefringence, extinction characteristics, and signs of elongation. The same characteristics are
used to identify the non asbestos constituents.
The microscopist visually estimates relative amounts of each constituent using a stereoscope if
necessary. The test results are based on a visual determination of relative volume of the bulk
1 Family Dwelling SNIP Asbestos Inspection W:/Word/HMG/13 Projects/13-2000-399.3215
3215 North 23rd Street December 23, 2013
Milwaukee, Wisconsin
Contract # 360-13-0745
3
sample components. The results are valid only for the item tested. Current US EPA NESHAP
regulations state asbestos materials means material containing more than 1% asbestos as
determined using the method specified in Appendix E, Subpart E, 40 CFR Part 763 Section I,
Polarized Light Microscopy. Refer to 29 CFR 1926.1101 (Construction) and 29 CFR 1910.1001
(General Industry) for specific OSHA requirements.
IV. FINDINGS AND OBSERVATIONS
The materials identified as suspect asbestos containing materials (ACM) include included plaster,
texture, drywall, blown in insulation, duct paper, linoleum, flue packing, joint compound patch,
window glazing compound, and asphalt shingle siding. These materials were sampled and the
following results were noted:
Sample # Location and Description Results Approximate
Quantity
Homogeneous
Code
1-3215 2nd floor – east room – west wall – plaster Negative N/A SPl
2-3215 2nd floor – east room – ceiling – plaster Negative N/A SPl
3-3215 1st floor – dining room – west wall – plaster base
coat
Negative N/A SPl
4-3215 1st floor – front room – north wall – plaster Negative N/A SPl
5-3215 Basement – stair – south wall – plaster Negative N/A SPl
6-3215a 2nd floor – east room – west wall – joint compound Negative N/A MDW
6-3215b 2nd floor – east room – west wall – joint compound
layer 2
Negative N/A MDW
6-3215c 2nd floor – east room – west wall – drywall Negative N/A MDW
7-3215a 2nd floor – main room – south wall – joint
compound
Negative N/A MDW
7-3215b 2nd floor – main room – south wall – joint
compound layer 2
Negative N/A MDW
7-3215c 2nd floor – main room – south wall – drywall Negative N/A MDW
8-3215a 1st floor – kitchen – west wall – joint compound Negative N/A MDW
8-3215b 1st floor – kitchen – west wall – joint compound
layer 2
Negative N/A MDW
8-3215c 1st floor – kitchen – west wall – drywall Negative N/A MDW
9-3215 2nd floor – northeast crawl space – in wall – blown
in insulation
Negative N/A MBI
10-3215 1st floor – kitchen – in ceiling – blown in insulation Negative N/A MBI
11-3215 1st floor – dining room – in south wall – blown in
insulation
Negative N/A MBI
12-3215 1st floor – north bedroom – on south wall duct –
duct paper Quantity includes 1st floor and
basement ducts
Positive 25%
Chrysotile
6 Sq. Ft. TDW
13-3215a 1st floor – bathroom – on walls – texture layer 1 Negative N/A STX
13-3215b 1st floor – bathroom – on walls – texture layer 2 Negative N/A STX
13-3215b 1st floor – bathroom – on walls – texture layer 3 Negative N/A STX
14-3215 1st floor – rear stair – beige linoleum Negative N/A MFLe
15-3215 Basement – on chimney – flue packing Negative N/A TFP
16-3215 Basement – on north wall – joint compound patch Negative N/A MJC
17-3215 Basement – south window – glazing compound Negative N/A MPG
18-3215 Exterior – west wall – asphalt shingle siding Negative N/A MSS
19-3215 Exterior – east wall – asphalt shingle siding Negative N/A MSS
1 Family Dwelling SNIP Asbestos Inspection W:/Word/HMG/13 Projects/13-2000-399.3215
3215 North 23rd Street December 23, 2013
Milwaukee, Wisconsin
Contract # 360-13-0745
4
Sample # Location and Description Results Approximate
Quantity
Homogeneous
Code
20-3215 Exterior – south wall – asphalt shingle siding Negative N/A MSS
Notes: N/A = Not Applicable
Sq. Ft. = Square Feet
Assumed Category I Non-Friable Asbestos Containing Material:
Floor Level Location Description Approximate Quantity
Roof Dwelling Asphalt Shingles & Flashing 1,200 Sq. Ft.
1st Stair Floor Mastics 50 Sq. Ft.
Homogeneous Material Codes
SPl Plaster
STX Texture
MDW Drywall
MPG Glazing Compound
MBI Blown in Insulation
MJC Joint Compound Patch
MFLe Beige Linoleum
MSS Asphalt Shingle Siding
TDW Duct Paper
TFP Flue Packing
Note#1: Category I – Non-Friable Asbestos Containing Materials may become friable during mechanical
demolition activities or maybe considered friable prior to demolition activities due to its current
condition.
Note#2: If additional materials are discovered during demolition that are not listed above they are to be
assumed to be asbestos containing.
Note#3: A copy of this report should be transmitted to the demolition contractor.
Note#4: Additional duct paper may be within walls and ceilings.
Note#5: Estimated cost for friable asbestos removal…
V. EXCLUSIONS
Roof visible only from ground. No visible or accessible areas were excluded from the scope
of work.
HMG is not and shall not represent the building owner as its agent or representative for the
purpose of the US EPA/NESHAP and/or the WDNR/NR447 regulations, as owner/operator.
This report represents the condition of the building and its visible/accessible suspect asbestos
containing materials at the date and the times of the onsite inspection. Hidden materials or those
materials that could be present at the point of inspection, over and above those stated in the
inspection report, are the responsibility of the building owner and the demolition contractor.
1 Family Dwelling SNIP Asbestos Inspection W:/Word/HMG/13 Projects/13-2000-399.3215
3215 North 23rd Street December 23, 2013
Milwaukee, Wisconsin
Contract # 360-13-0745
5
VI. LIMITATIONS
The care and skill given to our procedures insures the most reliable test results possible. HMG
utilizes Quantem Laboratories for our Polarized Light Microscopy, unless otherwise specified by
the client. The findings and conclusions of HMG represent our professional opinions
extrapolated from limited data. Significant limited data is gathered during the course of the
preliminary asbestos specific site assessment. No other warranty is expressed or implied. Prior
to any abatement or renovation activities, it is recommended that HMG be provided the
opportunity to review such plans in order that the inspection and assessments contained herein
are properly interpreted and implemented.
This report and the information contained herein are prepared for the sole and exclusive use and
possession of the City of Milwaukee Department of Neighborhood Services. No other person or
entity may rely on this report or any information contained herein. Any dissemination of the
Report or any information contained herein is strictly prohibited without prior written
authorization from Harenda Management Group.
1 Family Dwelling SNIP Asbestos Inspection W:/Word/HMG/13 Projects/13-2000-399.3215
3215 North 23rd Street December 23, 2013
Milwaukee, Wisconsin
Contract # 360-13-0745
6
VII. PRE-DEMOLITION ENVIRONMENTAL CHECKLIST
1 Family Dwelling SNIP Asbestos Inspection W:/Word/HMG/13 Projects/13-2000-399.3215
3215 North 23rd Street December 23, 2013
Milwaukee, Wisconsin
Contract # 360-13-0745
7
This guide lists materials and products commonly found in buildings with examples. It is
not intended as a substitute for reading the rules and statutes and making your own
independent determination of their applicability to your demolition project. These
examples presented here do not represent an exhaustive listing of types of materials that
may be required to be removed from the building prior to demolition.
ASBESTOS
Persons conducting inspections for asbestos must hold a valid asbestos inspector
certification card issued by the State of Wisconsin, Dept. of Health & Family Services.
Please follow the Asbestos Inspection and Sampling Protocol for Buildings to be
Demolished or Renovated.
CFCs and HALONS
Equipment that may contain CFCs and Halons:
N/A Air Conditioners (roof top, room, and central)
N/A Dehumidifiers
N/A Heat Pumps
N/A Refrigerators, Freezers, Chillers
N/A Vending Machines, Food Display Cases
N/A Walk-in Coolers
N/A Water Fountains (bubblers)
N/A Fire Extinguishers (both portable and installed HALON
suppression systems)
N/A Water Coolers
LEAD
Lead or Lead Based Paint (LBP) is common in many older buildings. When recycling
construction and demolition debris, be aware that wood containing lead paint may not be
chipped and spread for landscaping. State law also prohibits the sale or transfer of any
fixture or other object containing LBP that might be placed upon any surface of a
dwelling, which is ordinarily accessible to children.
1 Family Dwelling SNIP Asbestos Inspection W:/Word/HMG/13 Projects/13-2000-399.3215
3215 North 23rd Street December 23, 2013
Milwaukee, Wisconsin
Contract # 360-13-0745
8
MERCURY
Products that may contain mercury:
LIGHTING
N/A Fluorescent Lights
N/A High Intensity Discharge
-Metal Halide
-High Pressure Sodium
-Mercury Vapor
N/A Neon
N/A Switches for lighting using mercury relays
-Look for any control associated with exterior or automated
lighting systems such as "Silent" wall switches.
HVAC
Check thermostats and any control associated with air handling units for switches
containing mercury.
HEATING, VENTILATING AND AIR CONDITIONING SYSTEMS
N/A Old Thermostats
N/A Aquastats
N/A Firestats
N/A Manometers
N/A Thermometers
BOILERS, FURNACES, HEATERS AND TANKS
N/A Mercury Flame Sensors by pilot lights
N/A Manometers, Thermometers, Gauges
N/A Pressure-trol
N/A Float or Level Controls
N/A Space Heaters
1 Family Dwelling SNIP Asbestos Inspection W:/Word/HMG/13 Projects/13-2000-399.3215
3215 North 23rd Street December 23, 2013
Milwaukee, Wisconsin
Contract # 360-13-0745
9
ELECTRICAL SYSTEMS
N/A Load Meters and Supply Relays
N/A Phase Splitters
N/A Microwave Relays
N/A Mercury Displacement Relays
PCBs
For electrical devices manufactured prior to 1987, it is safe to assume that they contain
PCBs and should be managed accordingly. Most equipment manufactured after this time
will say "PCB Free". The following is a list of areas in a building were PCBs may be
found:
N/A Transformers
N/A Capacitors (appliances, electronic equipment)
N/A Heat Transfer Equipment
N/A Light Ballasts
N/A Specialty Paints (such as for swimming pools or other industrial
applications)
N/A Sumps or Oil Traps (in maintenance and industrial facilities)
OTHER ENVIRONMENTAL ISSUES
N/A Hazardous Waste
N/A Oil Tanks
N/A Well Abandonment
N/A Junk Auto Tires
N/A Junk Vehicles
1 Family Dwelling SNIP Asbestos Inspection W:/Word/HMG/13 Projects/13-2000-399.3215
3215 North 23rd Street December 23, 2013
Milwaukee, Wisconsin
Contract # 360-13-0745
10
VIII. LABORATORY RESULTS
2033 Heritage Park Drive I Oklahoma City, OK 73120 I (405) 755-7272/ Fax (405) 755-2058
Polarized Light Microscopy Asbestos Analysis Report
QuanTEM Lab No. 230012 Client: Harenda Management Group Jolene Harenda Account Number: B929
Date Received:
Received By:
Date Analyzed:
Analyzed By:
Methodology:
QuanTEM Sample ID
001
002
003
004
005
006
006a
12/16/2013
Alex Raymond
12/17/2013
Crista! Veech
EPN600/R-93/116
Client Sample ID
1-3215
2-3215
3-3215
4-3215
5-3215
6-3215
Composition
Homogeneous
Homogeneous
Homogeneous
Homogeneous
Homogeneous
Layered
Layered
1237 West Bruce St. Milwaukee, WI 53204
Project: DNS
Project Location: Milwaukee, WI
Project Number: 13-2000-399.3215
Color I Description
White
Sheetrock
White
Sheetrock
Gray
Plaster
Gray
Plaster
Gray
Plaster
White
Texture
White
Joint Compound
Asbestos(%)
Asbestos Not Present
ASbestos Not Present
Asbestos Not Present
Asbestos Not Present
Asbestos Not Present
Asbestos Not Present
Asbestos Not Present
Non-Asbestos Non Fibrous Fiber(%)
Cellulose I 0 Gypsum Mica
Cellulose 10 Gypsum Mica
NA Sand Gypsum
Cellulose 2 Sand Gypsum
Cellulose 2 Sand Glass Fiber <1 Gypsum
NA CaC03
NA
Perlite Paint
CaC03 Perlite
Unless otherwise noted, upon receipt the condition of the sample was acceptable for analysis.
QuanTEM is a NVLAP accredited PLM laboratory (Lab Code: 10 1959-0). This report relates only to the specific items tested. NVLAP accreditation applies only to analysis perfonned utilizing EPN600/M4-82-020 and EPN600/R-93/116 methods. This report may not be used to claim product endorsement by NVLAP or any agency
of the US Government. This report may not be reproduced except in full, without the written approval of the laboratory.
Page 1 of 5
2033 Heritage Park Drive I Oklahoma City, OK 73120 I (405) 755-7272/ Fax (405) 755-2058
Polarized Light Microscopy Asbestos Analysis Report
QuanTEM Lab No. 230012 Client: Harenda Management Group
Account Number: B929 Jolene Harenda 1237 West Bruce St.
Date Received: 12/ 16/2013 Milwaukee, WI 53204
Received By: Alex Raymond
Date Analyzed: 12/ 17/2013 Project: DNS
Analyzed By: Crista! Veech Project Location: Milwaukee, WI
Methodology: EPA/600/R-931116 Project Number: 13-2000-399.3215
QuanTEM Client Color I Non-Asbestos Non Fibrous Sample JD Sample ID Composition Description Asbestos(%) Fiber(%)
006b Layered White Asbestos Not Present Cellulose 3 Gypsum
Sheetrock
007 7-3215 Layered White Asbestos Not Present NA CaC03
Texture Perlite Paint
007a Layered White Asbestos Not Present NA CaC03
Joint Compound Perlite
007b Layered White Asbestos Not Present Cellulose 3 Gypsum
Sheetrock
008 8-3215 Layered White Asbestos Not Present NA CaC03
Texture
008a Layered White Asbestos Not Present NA CaC03
Joint Compound
008b Layered White Asbestos Not Present Cellulose 5 Gypsum
Sheetrock
Unless otherwise noted, upon receipt the condition of the sample was acceptable for analysis.
QuanTEM is a NVLAP accredited PLM laboratory (Lab Code: I 01959-0). This report relates only to the specific items tested. NVLAP accreditation applies only to analysis performed utilizing EPN600/M4-82-020 and EPA/600/R-93/116 methods. This report may not be used to claim product endorsement by NVLAP or any agency
of the US Government. This report may not be reproduced except in full, without the written approval of the laboratory.
Page 2 of 5
2033 Heritage Park Drive I Oklahoma City, OK 73120 I (405) 755-7272 / Fax (405) 755-2058
Polarized Light Microscopy Asbestos Analysis Report
QuanTEM Lab No_ 230012 Client: Harenda Management Group
Account Number: B929 Jolene Harenda 1237 West Bruce St.
Date Received: 12/ 16/2013 Milwaukee, WI 53204 Received By: Alex Raymond
Date Analyzed: 12/ 17/2013 Project: DNS
Analyzed By: Cristal Veech Project Location: Milwaukee, WI
Methodology: EPA/600/R-93/116 Project Number: 13-2000-399.3215
QuanTEM Client Color I Non-Asbestos Non Fibrous Sample ID Sample ID Composition Description Asbestos(%) Fiber(%)
009 9-3215 Homogeneous Tan Asbestos Not Present Cellulose 100
Insulation
010 10-3215 Homogeneous Tan Asbestos Not Present Cellulose 100
Insulation
011 11-3215 Homogeneous Tan Asbestos Not Present Cellulose 100
Insulation
012 12-3215 Homogeneous Gray Asbestos Present NA Vinyl
Sheet Vinyl Chrysolite 25
013 13-3215 Layered White Asbestos Not Present NA CaC03
Texture Paint
013a Layered Tan Asbestos Not Present NA Gypsum
Skim Coat Sand
013b Layered White Asbestos Not Present Cellulose 3 Sand
Plaster Gypsum
Unless otherwise noted, upon reeeipt the condition of the sample was acceptable for analysis.
QuanTEM is a NVLAP accredited PLM laboratory (Lab Code: 101959-0). This report relates only to the specific items tested. NVLAP accreditation applies only to analysis perfom1ed utilizing EPA/600!M4-82-020 and EPA/600/R-931116 methods. This report may not be used to claim product endorsement by NVLAP or any agency
of the US Government This report may not be reproduced except in full, without the written approval of the laboratory.
Page 3 of 5
1111!!!1!!.-!!!.J!!!!!® ---~iii ••• LABORATORIES
2033 Heritage Park Drive f Oklahoma City, OK 73120 I (405) 755-7272/ Fax (405) 755-2058
Polarized Light Microscopy Asbestos Analysis Report
QuanTEM Lab No. 230012 Client: Harenda Management Group Jolene Harenda Account Nwnber: 8929
Date Received:
Received By:
Date Analyzed:
Analyzed By:
Methodology:
QuanTEM Sample ID
014
015
016
017
018
019
020
12/16/2013
Alex Raymond
12/17/2013
Cristal V eech
EPA/600/R~93/ll6
Client SampleiD
14-3215
15-3215
16-3215
17-3215
18-3215
19-3215
20-32 15
Composition
Homogeneous
Homogeneous
Homogeneous
Homogeneous
Homogeneous
Homogeneous
Homogeneous
1237 West Bruce St. Milwaukee, WI 53204
Project: DNS
Project Location: Milwaukee, WI
Project Number: 13-2000-399.3215
Color I Description
Tan
Sheet Vinyl Backing
Yellow
Plaster
Gray
Plaster
Tan
Window Glazing
Gray
Siding
Gray
Siding
Gray
Siding
Asbestos (%)
Asbestos Not Present
Asbestos Not Present
Asbestos Not Present
Asbestos Not Present
Asbestos Not Present
Asbestos Not Present
Asbestos Not Present
Non-Asbestos Non Fibrous Fiber(%)
Cellulose 90 Binder
NA Sand CaC03 Paint
Cellulose 2 Sand
Glass Fiber <1 CaC03
NA CaC03
Cellulose 40 Tar Sand
Cellulose 40 Tar Sand
Cellulose 40 Tar Sand
Unless otherwise noted, upon receipt the condition of the sample was acceptable for analysis.
QuanTEM is a NVLAP accredited PLM laboratory (Lab Code: I 0 1959-0). This report relates only to the specific items tested. NVLAP accreditation applies only to analysis performed utilizing EP AI600/M4-82-020 and EP A/600/R -93/ I t 6 methods. This report may not be used to claim product endorsement by NVLAP or any agency
of the US Government. This report may not be reproduced except in full, without the written approval of the laboratory.
Page 4 of5
2033 Heritage Park Drive / Oklahoma City, OK 73120 I (405) 755-7272/ Fax (405) 755-2058
Polarized Light Microscopy Asbestos Analysis Report
QuanTEM Lab No. 230012 Client: Harenda Management Group Jolene Harenda Account Number: B929
Date Received: 12/16/2013 1237 West Bruce St. Milwaukee, WI 53204
Received By:
Date Analyzed:
Analyzed By:
Methodology:
Alex Raymond
12/17/2013
Crista! V eech
EPA/600/R-93/116
Project: DNS
Project Location: Milwaukee, WI
Project Number: 13-2000-399.3215
QuanTEM Client Color I
~~~~ Qr~~·ption · Cci.tal V0<oh,ll.JY;l
Asbestos(%)
12/ 17/2013 Date of Report
Unless otherwise noted, upon receipt the condition of the sample WIIS acceptable for analysis.
Non-Asbestos F iber(%)
Non Fibrous
QuanTEM is a NVLAP accredited PLM laboratory (Lab Code: 101959-0). This report relates only to the specific items tested. NVLAP accreditation applies only to analysis performed utilizing EPA/600/M4-82-020 and EPA/600/R-93/116 methods. This report may not be used to claim product endorsement by NVLAP or any agency
of the US Government. This report may not be reproduced except in full, without the written approval of the laboratory.
Page 5 of 5
ASBESTOS CHAIN OF CUSTODY 2033 Heritage Park Drive, Oklahoma City, OK 73120-7502 (800) 822-1650 • (405) 755-7272 • Fax: (405) 755-2058
LEGAL DOCUMENT- PLEASE PRINT LEGIBLY
Page 1 of .:(
~--····--·-·-··-·-·-
For Lab US« Only
Lab No. '~> c:s::) l ?-.
~ Reject . . . .....___......-------.
. . : ~roject Information Report Results (ltf one bOX) · Contact lllformation · .... ·· ··
Company: Harenda Management Group
Contact: Dean Jacobsen
Account 1: 8929
SAMPLED BY: I Nam~ " " RELINQUISHfD8Y ,·-·.
_\_)~\Yd~ \
,.
PhoM: ( 414) 383-4800 Project Name: DNS D QuanTEM Website
Cell Phone: ProJectLocation: Milwaukee, WI 0 Other email
E-mail: [email protected] II Project ID: 13-2000-399.3215
Date: P.O. Number:
· J~DAtf& TIME.·.·. [ · ... ·. VIA I ' .. RECEIVED BY' DATE&TIME
I!Z/Cz.l\~ l~ I fc-JXl( J..~~ IV/~ I t!> r <::b.--..
( REOuesTeo s~RVJ~s · {PI~~~~~J':ih~-~pj:,rop~e foxes> ·
'" PlJ\,t> Pi..M~ _ . _. : . TEM~ <; ·· . TEM TURNAROUND TIME [iJ. BulkAnalysis(EPA600/R-93/116) D VermicullteAtticlnsulation 0 Air- AHERA 0 Bulk-Presence/AbsenceEPA600/R-93/116 0 Rush
r {EPA 600/R-o-t/004) D 400 Point Count D Other 0 Air- NIOSH 7402 0 Bulk- Quantitative [weight%]- Chatfield 0 Same Day
0 1000 Point Count 0 Air- ISO 103~2 0 Dust- Presence / Absence 0 24- Hour
0 G~'"'""' ""'"'~"'" I :. . ·: · ' •. · · .P<i'M . ., j 0 D•lnking ,.,.,_EPA 1002 O """-Q"'"'"""' (ftboW"l-=1-ASTM 05755 ~ 3 _ Day l D Particle ID 0 I NIOSH 7400 0 Waste Water- EPA 600/4-83-043 0 Other 0 5 - Day
No.I (-t.Q,:.:rtJ:~MI~), .--~ ~ ~'I' ,~ :. I~: :'_ ~~lor < •. _,,.,, • . . , .. , •• • ~ • •
Comm~nts.l Notes .. · ~;;~·-, : ... ~:. , .. : •. (:•••.)i~~~~riptifn '.·· vOlume/Area · .. (isa~l~e)
1 I I~ 3215 I ~ 2 IZr-32!5 I C 3 13 -32(5
4 ' '{~ aJ 5 15- ~2(5 OJ 6 I f>--£\5 I1J 7 1 7-32(~ [ 8 l 'g- 3Zt5"" [ 9 fY -3'45 [ 10 I[;) -~5 ~
SATURDAY SAMPLE DELIVERY- CALL TO SCHEDULE • Use this address for Saturday Delivery only: 4220 N. Santa Fe Ave., Oklahoma City, OK 73105-8517 • Mark Package "Hold for Saturday Pickup"
BORA TORIES www.QuanTEM.com
ProJect Information · ·.. . .. (-'· .. ... · .. .·
company: Harenda Management Group
No. Sample tO . . ··· lit· To Be 1 Color·.· ..... .... (1 0-Charact,rs .Max) . ·.A~ ·.· . .. ·. · .. . · ..
11 q --326 u;:J 12 /'l. ~ 32-CS [ 13 (3 -~2(5 [ 14 I <-{ - "3Zlt; [ 15 {5 -32L5 [ 16 t0 -32(.) [ 17 \r-32ts [ 18 \i' -=)Zl5 [ 19 l/-~2l_5 [ D 20 '2D ~?;2{5 B c: 21 D 22 D 23 D 24 D 25 D 26 D 27 0 28 D 29 D 30 ,_ D -
ASBESTOS CHAIN OF CUSTODY 2033 Heritage Park Drive, Oklahoma City, OK 731 20-7502 (800) 822-1650 • (405) 755-7272 • Fax: (405) 755-2058
LEGAL DOCUMENT - PLEASE PRINT LEGIBLY
.. .......... ....... · ...............
Page 2 of 'Z..... ,-----·-·--··-·--·---··--·----·--·--·
For .Lab use only
Lab No. ~36o 1 '?-Accept Re;ect
.
I Project Name: DNS I Project Location: Milwaukee, WI
. .. · · Oes~ription Volume./ Area .• Comment~ I Notes . . ·.• <.(c)s iippiable> 1
·.
.1b ~ \ e(t ~+..t
-
-
SATURDAY SAMPlE DEliVERY -CALl TO SCHEDULE • Use this address for Saturday Delivery only: 4220 N. Santa Fe Ave., Oklahoma City, OK 73105-8517 • Mark Package "Hold for Saturday Pi(kup"
"'
I
'
1 Family Dwelling SNIP Asbestos Inspection W:/Word/HMG/13 Projects/13-2000-399.3215
3215 North 23rd Street December 23, 2013
Milwaukee, Wisconsin
Contract # 360-13-0745
11
IX. HMG CERTIFICATION
1237 West Bruce Street · Milwaukee, Wisconsin 53204 · (414) 383-4800 · (414) 383-4805
ASBESTOS SNIP INSPECTION REPORT
Job Site:
One Family Dwelling
3227 North 25th
Street
Milwaukee, Wisconsin
For:
City of Milwaukee
Department of Neighborhood Services
Attn: Marge Piwaron
841 North Broadway 1st Floor
Milwaukee, Wisconsin 53202-3613
HMG Report No.: 13-2000-399.3227
Contract No.: 360-13-0745
________________________ Dean Jacobsen
Asbestos Inspector No. AII – 14370
Prepared by:
HARENDA MANAGEMENT GROUP
1237 West Bruce Street
Milwaukee, Wisconsin 53204
December 2013
1 Family Dwelling SNIP Asbestos Inspection W:/Word/HMG/13 Projects/13-2000-399.3227
3227 North 25th Street December 23, 2013
Milwaukee, Wisconsin
Contract # 360-13-0745
1
TABLE OF CONTENTS
I. Introduction ..............................................................................................................2
II. Building Survey .......................................................................................................2
III. The Laboratory .........................................................................................................2
A. Method of Analysis
IV. Findings and Observations .......................................................................................3
V. Exclusions ................................................................................................................4
VI. Limitations ...............................................................................................................5
VII. Pre-Demolition Environmental Checklist…………………………………………6
VIII. Laboratory Results .................................................................................................10
IX. HMG Certifications ...............................................................................................11
1 Family Dwelling SNIP Asbestos Inspection W:/Word/HMG/13 Projects/13-2000-399.3227
3227 North 25th Street December 23, 2013
Milwaukee, Wisconsin
Contract # 360-13-0745
2
I. INTRODUCTION
Harenda Management Group (HMG) was retained by the City of Milwaukee Department of
Neighborhood Services to conduct an inspection for possible asbestos containing materials in the
dwelling at 3227 North 25th Street, Milwaukee, Wisconsin.
The inspection included plaster, tar paper, drywall/joint compound, blown in insulation,
linoleum, duct paper, flue packing, and window glazing compound to determine if asbestos
containing materials were present within the space as required by US EPA NESHAP regulation
40 CFR 61 Subpart M.
II. BUILDING SURVEY
Marge Piwaron, of the City of Milwaukee Department of Neighborhood Services, authorized
HMG to conduct a building survey and to analyze samples taken during the inspection.
On December 13, 2013, HMG conducted an asbestos inspection of a one family dwelling,
scheduled for mechanical demolition, located at 3227 North 25th Street, Milwaukee,
Wisconsin. The inspection was conducted by Demicca Coe, Wisconsin License No. AII –
156385.
The inspection was comprised of three elements:
1. A visual determination as to the extent of suspect materials within the building.
2. Sampling and documentation of observable suspect materials. Category I non-friable
materials were assumed to be asbestos containing and not sampled.
3. Quantification of observable positive materials existing within the spaces.
The results of the survey integrated with the Polarized Light Microscopy with Dispersion
Staining (PLM/DS) analysis of bulk samples taken are outlined in this document. If you have
any questions please contact HMG at (414) 383-4800.
III. THE LABORATORY
A. METHOD OF ANALYSIS
Analysis is performed by using the bulk samples for visual observation and slide preparation(s)
for microscopical examination and identification. The slides are analyzed for asbestos
(chrysotile, amosite, crodcidolite, anthophyllite, and actinolite/ tremolite), fibrous non asbestos
constituents (mineral wool, paper, etc.), and nonfibrous constituents. Asbestos is identified by
refractive indices (obtained by using dispersion staining), morphology, color, pleochroism,
birefringence, extinction characteristics, and signs of elongation. The same characteristics are
used to identify the non asbestos constituents.
The microscopist visually estimates relative amounts of each constituent using a stereoscope if
necessary. The test results are based on a visual determination of relative volume of the bulk
1 Family Dwelling SNIP Asbestos Inspection W:/Word/HMG/13 Projects/13-2000-399.3227
3227 North 25th Street December 23, 2013
Milwaukee, Wisconsin
Contract # 360-13-0745
3
sample components. The results are valid only for the item tested. Current US EPA NESHAP
regulations state asbestos materials means material containing more than 1% asbestos as
determined using the method specified in Appendix E, Subpart E, 40 CFR Part 763 Section I,
Polarized Light Microscopy. Refer to 29 CFR 1926.1101 (Construction) and 29 CFR 1910.1001
(General Industry) for specific OSHA requirements.
IV. FINDINGS AND OBSERVATIONS
The materials identified as suspect asbestos containing materials (ACM) include included plaster,
tar paper, drywall/joint compound, blown in insulation, linoleum, duct paper, flue packing, and
window glazing compound. These materials were sampled and the following results were noted:
Sample # Location and Description Results Approximate
Quantity
Homogeneous
Code
1-3227 Exterior – east wall under wood – tar paper Negative N/A MPT
2-3227 Exterior – north wall under wood – tar paper Negative N/A MPT
3-3227 Exterior – west wall under wood – tar paper Negative N/A MPT
4-3227a 2nd floor – dining room – south wall – plaster skim
coat
Negative N/A SPl
4-3227b 2nd floor – dining room – south wall – plaster base
coat
Negative N/A SPl
5-3227a 2nd floor – west bedroom – south wall – plaster
skim coat
Negative N/A SPl
5-3227b 2nd floor – west bedroom – south wall – plaster
base coat
Negative N/A SPl
6-3227a 2nd floor – rear stair – north wall – plaster skim
coat
Negative N/A SPl
6-3227b 2nd floor – rear stair – north wall – plaster base
coat
Negative N/A SPl
7-3227a Basement – stair – ceiling – plaster skim coat Negative N/A SPl
7-3227b Basement – stair – ceiling – plaster base coat Negative N/A SPl
8-3227a Attic – stair – west wall – plaster skim coat Negative N/A SPl
8-3227b Attic – stair – west wall – plaster base coat Negative N/A SPl
9-3227a 1st floor – bathroom – west wall – joint compound Negative N/A MDW
9-3227b 1st floor – bathroom – west wall – drywall Negative N/A MDW
10-3227a 1st floor – rear stair – east wall – joint compound Negative N/A MDW
10-3227b 1st floor – rear stair – east wall – drywall Negative N/A MDW
11-3227 Attic – bedroom – ceiling – drywall Negative N/A MDW
12-3227 Attic – bedroom – on floor – blown in insulation Negative N/A MBI
13-3227 Attic – west side – on floor – blown in insulation Negative N/A MBI
14-3227 Attic – north side – in ceiling – blown in insulation Negative N/A MBI
15-3227 1st floor – front entry – blue linoleum Negative N/A MFLb
16-3227 1st floor – kitchen – blue linoleum #2 Negative N/A MFLb2
17-3227 1st floor – bathroom – cream linoleum Negative N/A MFLc
18-3227 Basement – on stair – cream linoleum #2 Negative N/A MFLc2
19-3227 Basement – on boots – duct paper Quantity
includes 1st floor ducts
Positive 80%
Chrysotile
12 Sq. Ft. TDW
20-3227 1st floor – living room – on floor – tar paper #2 Negative N/A MPT2
21-3227 1st floor – living room – on floor – tar paper #2 Negative N/A MPT2
22-3227 1st floor – living room – on floor – tar paper #2 Negative N/A MPT2
23-3227 1st floor – rear stair – west window – glazing
compound
Negative N/A MPG
1 Family Dwelling SNIP Asbestos Inspection W:/Word/HMG/13 Projects/13-2000-399.3227
3227 North 25th Street December 23, 2013
Milwaukee, Wisconsin
Contract # 360-13-0745
4
Sample # Location and Description Results Approximate
Quantity
Homogeneous
Code
24-3227 1st floor – north bedroom – north window – glazing
compound
Negative N/A MPG
25-3227 Basement – south window – glazing compound Negative N/A MPG
26-3227 Basement – on chimney – flue packing Negative N/A TFP
Notes: N/A = Not Applicable
Sq. Ft. = Square Feet
Assumed Category I Non-Friable Asbestos Containing Material:
Floor Level Location Description Approximate Quantity
Roof Dwelling Asphalt Shingles & Flashing 1,100 Sq. Ft.
1st Front Entry/Kitchen/Bathroom/
Hall/Stair
Floor Tile & Mastics 250 Sq. Ft.
Homogeneous Material Codes
SPl Plaster
MPT Tar Paper
MPT2 Tar Paper #2
MDW Drywall/Joint Compound
MBI Blown in Insulation
MFLb Blue Linoleum
MFLb2 Blue Linoleum #2
MFLc Cream Linoleum
MFLc2 Cream Linoleum
MPG Glazing Compound
TDW Duct Paper
TFP Flue Packing
Note#1: Category I – Non-Friable Asbestos Containing Materials may become friable during mechanical
demolition activities or maybe considered friable prior to demolition activities due to its current
condition.
Note#2: If additional materials are discovered during demolition that are not listed above they are to be
assumed to be asbestos containing.
Note#3: A copy of this report should be transmitted to the demolition contractor.
Note#4: Additional duct paper may be within walls and ceilings.
Note#5: Estimated cost for friable asbestos removal…
V. EXCLUSIONS
Roof visible only from ground. No visible or accessible areas were excluded from the scope
of work.
HMG is not and shall not represent the building owner as its agent or representative for the
purpose of the US EPA/NESHAP and/or the WDNR/NR447 regulations, as owner/operator.
This report represents the condition of the building and its visible/accessible suspect asbestos
containing materials at the date and the times of the onsite inspection. Hidden materials or those
1 Family Dwelling SNIP Asbestos Inspection W:/Word/HMG/13 Projects/13-2000-399.3227
3227 North 25th Street December 23, 2013
Milwaukee, Wisconsin
Contract # 360-13-0745
5
materials that could be present at the point of inspection, over and above those stated in the
inspection report, are the responsibility of the building owner and the demolition contractor.
VI. LIMITATIONS
The care and skill given to our procedures insures the most reliable test results possible. HMG
utilizes Quantem Laboratories for our Polarized Light Microscopy, unless otherwise specified by
the client. The findings and conclusions of HMG represent our professional opinions
extrapolated from limited data. Significant limited data is gathered during the course of the
preliminary asbestos specific site assessment. No other warranty is expressed or implied. Prior
to any abatement or renovation activities, it is recommended that HMG be provided the
opportunity to review such plans in order that the inspection and assessments contained herein
are properly interpreted and implemented.
This report and the information contained herein are prepared for the sole and exclusive use and
possession of the City of Milwaukee Department of Neighborhood Services. No other person or
entity may rely on this report or any information contained herein. Any dissemination of the
Report or any information contained herein is strictly prohibited without prior written
authorization from Harenda Management Group.
1 Family Dwelling SNIP Asbestos Inspection W:/Word/HMG/13 Projects/13-2000-399.3227
3227 North 25th Street December 23, 2013
Milwaukee, Wisconsin
Contract # 360-13-0745
6
VII. PRE-DEMOLITION ENVIRONMENTAL CHECKLIST
1 Family Dwelling SNIP Asbestos Inspection W:/Word/HMG/13 Projects/13-2000-399.3227
3227 North 25th Street December 23, 2013
Milwaukee, Wisconsin
Contract # 360-13-0745
7
This guide lists materials and products commonly found in buildings with examples. It is
not intended as a substitute for reading the rules and statutes and making your own
independent determination of their applicability to your demolition project. These
examples presented here do not represent an exhaustive listing of types of materials that
may be required to be removed from the building prior to demolition.
ASBESTOS
Persons conducting inspections for asbestos must hold a valid asbestos inspector
certification card issued by the State of Wisconsin, Dept. of Health & Family Services.
Please follow the Asbestos Inspection and Sampling Protocol for Buildings to be
Demolished or Renovated.
CFCs and HALONS
Equipment that may contain CFCs and Halons:
N/A Air Conditioners (roof top, room, and central)
N/A Dehumidifiers
N/A Heat Pumps
N/A Refrigerators, Freezers, Chillers
N/A Vending Machines, Food Display Cases
N/A Walk-in Coolers
N/A Water Fountains (bubblers)
N/A Fire Extinguishers (both portable and installed HALON
suppression systems)
N/A Water Coolers
LEAD
Lead or Lead Based Paint (LBP) is common in many older buildings. When recycling
construction and demolition debris, be aware that wood containing lead paint may not be
chipped and spread for landscaping. State law also prohibits the sale or transfer of any
fixture or other object containing LBP that might be placed upon any surface of a
dwelling, which is ordinarily accessible to children.
1 Family Dwelling SNIP Asbestos Inspection W:/Word/HMG/13 Projects/13-2000-399.3227
3227 North 25th Street December 23, 2013
Milwaukee, Wisconsin
Contract # 360-13-0745
8
MERCURY
Products that may contain mercury:
LIGHTING
N/A Fluorescent Lights
N/A High Intensity Discharge
-Metal Halide
-High Pressure Sodium
-Mercury Vapor
N/A Neon
N/A Switches for lighting using mercury relays
-Look for any control associated with exterior or automated
lighting systems such as "Silent" wall switches.
HVAC
Check thermostats and any control associated with air handling units for switches
containing mercury.
HEATING, VENTILATING AND AIR CONDITIONING SYSTEMS
N/A Old Thermostats
N/A Aquastats
N/A Firestats
N/A Manometers
N/A Thermometers
BOILERS, FURNACES, HEATERS AND TANKS
N/A Mercury Flame Sensors by pilot lights
N/A Manometers, Thermometers, Gauges
N/A Pressure-trol
N/A Float or Level Controls
N/A Space Heaters
1 Family Dwelling SNIP Asbestos Inspection W:/Word/HMG/13 Projects/13-2000-399.3227
3227 North 25th Street December 23, 2013
Milwaukee, Wisconsin
Contract # 360-13-0745
9
ELECTRICAL SYSTEMS – 1 Breaker Box in Basement
N/A Load Meters and Supply Relays
N/A Phase Splitters
N/A Microwave Relays
N/A Mercury Displacement Relays
PCBs
For electrical devices manufactured prior to 1987, it is safe to assume that they contain
PCBs and should be managed accordingly. Most equipment manufactured after this time
will say "PCB Free". The following is a list of areas in a building were PCBs may be
found:
N/A Transformers
N/A Capacitors (appliances, electronic equipment)
N/A Heat Transfer Equipment
N/A Light Ballasts
N/A Specialty Paints (such as for swimming pools or other industrial
applications)
N/A Sumps or Oil Traps (in maintenance and industrial facilities)
OTHER ENVIRONMENTAL ISSUES
N/A Hazardous Waste
N/A Oil Tanks
N/A Well Abandonment
N/A Junk Auto Tires
N/A Junk Vehicles
* ½ Gallon Ammonia in Kitchen
* 1 Gas Meter in Basement
1 Family Dwelling SNIP Asbestos Inspection W:/Word/HMG/13 Projects/13-2000-399.3227
3227 North 25th Street December 23, 2013
Milwaukee, Wisconsin
Contract # 360-13-0745
10
VIII. LABORATORY RESULTS
2033 Heritage Park Drive I Oklahoma City, OK 73120 I (405) 755-7272/ Fax (405) 755-2058
Polarized Light Microscopy Asbestos Analysis Report
QuanTEM Lab No. 230008 Client: Harenda Management Group
Account Number: B929 Jolene Harenda 1237 West Bruce St.
Date Received: 12/16/2013 Milwaukee, WI 53204
Received By: Alex Raymond
Date Analyzed: 12/18/2013 Project: DNS
Analyzed By: Sandy Baker Project Location: Milwaukee, WI
Methodology: EPA/600/R-931116 Project Number: 13-2000-399.3227
QuanTEM Client Color/ Non-Asbestos Non Fibrous SampleiD Sample lD Composition Description Asbestos (%) Fiber(%)
001 1-3227 Homogeneous Black Asbestos Not Present Cellulose 60 Tar
TarPaper
002 2-3227 Homogeneous Black Asbestos Not Present Cellulose 60 Tar
Tar Paper
003 3-3227 Homogeneous Black Asbestos Not Present Cellulose 60 Tar
Tar Paper
004 4-3227 Layered White Asbestos Not Present Cellulose 2 Quartz
Plaster Sand Paint
004a Layered Tan Asbestos Not Present Cellulose 2 Quartz
Plaster Sand
005 S-3227 Layered White Asbestos Not Present NA Quartz
Plaster Sand Paint
005a Layered Tan Asbestos Not Present NA Quartz
Plaster Sand
Unless otherwise noted, upon receipt the condition of the sample was acceptable for analysis.
QuanTEM is a NVLAP accredited PLM laboratory (Lab Code: 1 01959-0). This report relates only to the specific items tested. NVLAP accreditation applies only to analysis performed utilizing EP N600/M4-82-020 and EP N6001R-93/1 16 methods. This report may not be used to claim product endorsement by NV LAP or any agency
ofthe US Government. This report may not be reproduced except in full, without the written approval of the laboratory.
Page 1 of5
2033 Heritage Park Drive I Oklahoma City, OK 73120 I (405) 755-72721 Fax (405) 755-2058
Polarized Light Microscopy Asbestos Analysis Report
QuanTEM Lab No. 230008 Client: Harenda Management Group
Jolene Harenda Account Number:
Date Received:
Received By:
Date Analyzed:
Analyzed By:
Methodology:
QuanTEM Sample lD
B929
12/16/2013
Alex Raymond
12/18/2013
Sandy Baker
EPA/600/R-93/116
Client Sample ID Composition
Project: DNS
123 7 West Bruce St. Milwaukee, WI 53204
Project Location: Milwaukee, WI
Project Number: 13-2000-399.3227
Color I Description Asbestos(%)
Non-Asbestos Fiber(%)
·--· --- --- ·-- --- ·--- ---~~- ·---------
006 6-3227 Layered White Asbestos Not Present Cellulose
Plaster
006a Layered Tan Asbestos Not Present Cellulose
Plaster
007 7-3227 Layered White Asbestos Not Present Cellulose
Plaster
007a Layered Tan Asbestos Not Present Cellulose
Plaster
008 8-3227 Layered White Asbestos Not Present Cellulose
Plaster
008a Layered Tan Asbestos Not Present Cellulose
Plaster
Unless otherwise noted, upon receipt the condition of the sample was acceptable for analysis.
2
2
<1
3
2
2
Non Fibrous
Quartz Sand Paint
Quartz Sand
Quartz Sand Paint
Quartz Sand
Quartz Sand Paint
Quartz Sand
QuanTEM is a NVLAP accredited PLM laboratory (Lab Code: 101959-0). This report relates only to the specific items tested. NVLAP accreditation applies only to analysis performed utilizing EPN600fM4-82-020 and EPA/600/R-93/116 methods. This report may not be used to claim product endorsement by NVLAP or any agency
of the US Government. This report may not be reproduced except in full, without the ·written approval of the laboratory.
Page 2 of5
2033 Heritage Park Drive I Oklahoma City, OK 73120 I (405) 755-7272 1 Fax (405) 755-2058
Polarized Light Microscopy Asbestos Analysis Report
QuanTEM Lab No. 230008 Client: Harenda Management Group
Account Number: B929 Jolene Harenda 1237 West Bruce St.
Date Received: 12116/2013 Milwaukee, WI 53204
Received By: Alex Raymond
Date Analyzed: 12/ 18/2013 Project: DNS
Analyzed By: Sandy Baker Project Location: Milwaukee, WI
Methodology: EPA/600/R-93/116 Project Number: 13-2000-399.3227
QuanTEM Client Color I Non-Asbestos Non Fibrous Sample ID Sample ID Composition Description Asbestos(%) Fiber(%)
- -·-- - ·
009 9-3227 Layered White Asbestos Not Present NA CaC03
Texture Paint
009a Layered White Asbestos Not Present Cellulose 30 Gypsum
Sheetrock
010 10-3227 Layered White Asbestos Not Present NA CaC03
Joint Compound
OIOa Layered White Asbestos Not Present Cellulose 30 Gypsum
Sheetrock
011 I 1-3227 Homogeneous White Asbestos Not Present Cellulose 35 Gypsum
Sheetrock
012 12-3227 Homogeneous Tan Asbestos Not Present Cellulose 100
Insulation
013 13-3227 Homogeneous Tan Asbestos Not Present Cellulose 100
Insulation
Unless otherwise noted, upon receipt the condition of the sample was acceptable for analysis.
QuanTEM is a NV LAP accredited PLM laboratory (Lab Code: I 01959-0). This report relates only to the specific items tested. NVLAP accreditation applies only to analysis performed utilizing EPA/600/M4-82-020 and EPA/600/R-93/116 methods. This report may not be used to claim product endorsement by NVLAP or any agency
of the US Government. This report may not be reproduced except in full, without the written approval of the laboratory.
Page 3 of 5
2033 Heritage Pari< Drive I Oklahoma City, OK 73120 I (405) 755-7272/ Fax (405) 755-2058
Polarized Light Microscopy Asbestos Analysis Report
QuanTEM Lab No. 230008 Client: Harenda Management Group
Account Number: B929 Jolene Harenda 1237 West Bruce St.
Date Received: 12/16/2013 Milwaukee, WI 53204
Received By: Alex Raymond
Date Analyzed: 12118/2013 Project: DNS
Analyzed By: Sandy Baker Project Location: Milwaukee, WI
Methodology: EPA/600/R-93/116 Project Number: 13-2000-399.3227
QuanTEM Client Color I Non-Asbestos Non Fibrous
Sample ID Sample ID Composition Description Asbestos(%) Fiber(%)
----
014 14-3227 Homogeneous Tan Asbestos Not Present Cellulose 100
Insulation
015 15-3227 Homogeneous Brown Asbestos Not Present Cellulose 25 Vinyl
Sheet Vinyl Glass Fiber 5 Foam
016 16-3227 Homogeneous Tan/Brown Asbestos Not Present Cellulose 25 Vinyl
Sheet Vinyl Glass Fiber 5 Foam
017 17-3227 Homogeneous Tan Asbestos Not Present Cellulose 25 Vinyl
Sheet Vinyl Glass Fiber 5 Foam
018 18-3227 Homogeneous Cream Asbestos Not Present Cellulose 25 Vinyl
Sheet Vinyl Glass Fiber 5 Foam
019 19-3227 Homogeneous Light Gray Asbestos Present NA Debris
Insulation Chrysotile 80
020 20-3227 Homogeneous Black Asbestos Not Present Cellulose 60 Tar
Tar Paper
Unless otherwise noted, upon receipt the condition of the sample was acceptable for analysis.
QuanTEM is a NVLAP accredited PLM laboratory (Lab Code: 101959-0). This report relates only to the specific items tested. NVLAP accreditation applies only to analysis performed utilizing EPA/600/M4-82-020 and EPA/600/R-93/116 methods. This report may not be used to claim product endorsement by NV LAP or any agency
of the US Government. This report may not be reproduced except in full, without the written approval of the laboratory.
Page 4 of 5
2033 Heritage Park Drive I Oklahoma City, OK 73120 I (405) 755-7272/ Fax (405) 755-2058
Polarized Light Microscopy Asbestos Analysis Report
QuanTEM Lab No. 230008 Client Harenda Management Group
Account Number: B929 Jolene Harenda 1237 West Bruce St.
Date Received: 12/16/2013 Milwaukee, WI 53204
Received By: Alex Raymond
Date Analyzed: 12/18/2013 Project: DNS
Analyzed By: Sandy Baker Project Location: Milwaukee, WI
Methodology: EPA/600/R-93/116 Project Number: 13-2000-399.3227
QuanTEM Client Color I Non-Asbestos Non Fibrous
Sample ID Sample ID Composition Description Asbestos(%) Fiber(%)
021 21-3227 Homogeneous Black Asbestos Not Present Cellulose 60 Tar
Tar Paper
022 22-3227 Homogeneous Black Asbestos Not Present Cellulose 60 Tar
Tar Paper
023 23-3227 Homogeneous Tan Asbestos Not Present NA CaC03
Window Glazing Paint
024 24-3227 Homogeneous Tan Asbestos Not Present NA CaC03
Window Glazing Paint
025 25-3227 Homogeneous Black Asbestos Not Present NA CaC03
Window Glazing
026 26-3227 Homogeneous Light Gray Asbestos Not Present NA CaC0 3
Window Glazing
12118/2013
Date of Report
Unless o erwise noted, upon receipt the condition of the sample was acceptable for analysis.
Q uanTEM is a NV LAP accredited PLM laboratory (Lab Code: 101959-0). This report relates only to the specific items tested. NVLAP accreditation applies only to analysis performed utilizing EPN600/M4-82-020 and EPN600fR-93/1 16 methods . This report may not be used to claim product endorsement by NVLAP or any agency
of the US Government. This report may not be reproduced except in full, without the written approval ofthe laboratory.
Page 5 of 5
ASBESTOS CHAIN OF CUSTODY Page 1 of ~
~-t~I:IY~ .2033 Heritage Park D rive, Oklahoma City, OK 73120-7502 ~ - ·--·- -·
(800) 822-1650 • (405) 755-7272 • Fax: (405) 755-2058 For Lab Use Only
LABORATORIES d~ ·.' · Lab No. J.2 COo "'~ www.QuanTEM.com LEGAL DOCUMENT - PLEASE PRINT LEGIBLY ~ Reject
Contact thformation · · .. Proj~ct Information ..
·Report Restnts (li:1 on~ box) . Company; Harenda Management Group Phone: ( 414) 383-4800 Project Name: DNS D QuanTEM Website
Contact: Dean Jacobsen Cell Phone: ProJectlocation: Milwaukee, WI 0 Other email Account 1: 6929 E-mail: [email protected] ProjectiO: 13-2000-399.3227
SAMPLEP Br. .1 Name: Date: P.O. Number:
. ( \ ·· \'\RCEtiNQUISHEDBY. ·. '•· . •· <<DATE~ TIME' .. . .
·.· . . .. VIA RECEIVJ;O ·BY .DATE&TJME
\ 1 i;n)'JJ UA (Z{rz./t?J ~ f~ JJ~~) /')..jf &/( 3 /Oo. ,.__ ....
\ (} .... ·:,.. .. , ; ·- JteOUESTEO·SUVf(;E,~ .f~- Ql'·. the.~,r~PiYate aOx.e$) ·. ·.' .. ::: .. :
· Pl M · .···· .·, · ~~· > .. ··.: .. :. ·/ TfM· ' · TEM ·· TURNAROUND TIME ·.· ' ~ .. . . . ' · .. · ....
liJ Bulk Analysis (EPA 600/R-93/ 116) D Vermiculite Attic Insulation D Alr- AHERA D Bulk- Presence I Absence EPA600/R-93/116 D Rush
C (EPA 600/ R-04/004)
D D D 400 Point Count
D Air- NIOSH 7402 Bulk- Quantitative [weight%)- Chatfield Same Day
Other r- 1000 Point Count D Air- ISO 10312 D Dust- Presence I Absence D 24 - Hour ..-
Gravimetric Preparation I ·· .. ·PCM · . I D Drinking Water- EPA 1 00.2 D Dust- Quantitative [fibers/sq.cm)- ASTM 05755 ~ 3 - Day
D Particle 10 : t:l l NI~SH ';40~ ·- . . : D Waste Water- EPA 600/4-83-043 D Other D 5-Day
No~ · ~mple' IP : _ ·. it! To Be .. COlOr, . : ; _ .... ·., ·_. , _;: ., . : oesctilp~~"'\ <~-~. ~ :.·:: ·~ .. . ·. ···.·. . Volume / Area ·•. Comments/ Notes
·. {IO ~haracters ·Max>· .. · :~; ·· ... ·~..: .. _)~- : .- .:.- · .. _
- ·····~~>·· : •.
1 ( -3221 [(] ·-
2 () -~ [ 3 '3-?221 [ 4 ~ -~ZZI [ 5 5 -"322( [ 6 ~-?Qz( _[ 7 7~~27.1 [ 8 :o-~' [ 9 9-?Jzzl [ 10 tu-~r J!]_
-
SATURDAY SAMPLE DELIVERY · CALL TO SCHEDULE • Use thisaddress for Saturday Delivery only: 4220 N. Santa Fe Ave., Oklahoma City, OK 73105-8517 • Mark Padcage "Hold fM Saturday Pkkupn
.. -.DvRATORIES www.QuanTEM.com
Project lnfprml)tion
company: Harenda Management Group
No. ·sample 10 lti.ToBe {10 Characters Max)· Analyzed
11 (( . ")22[ 00 12 12.-:a-, [ 13 !.? -~~ h 14 /'7-~1 [ 15 15 -?;a_( [ 16 l?::>-~( [ 17 11-~\ [ 18 rg -""t>'l2r [] 19 I'? -~"2.2.( [ 20 2;:)-~221 [ 21 -z1 -'3Zzc c 22 22--~227 c 23 "23 ·-?2Zr [ 24 2~-322.7 [ 25 zs_ ~a-r c 26 "-322.\ ~ 27 D 28 D 29 D 30 D
Color. .
ASBESTOS CHAIN OF CUSTODY 2033 Heritage Park Drive, Oklahoma City, OK 73120-7502 (BOO) 822-1650 • (405) 755-7272 • Fax: (405) 755-2058
LEGAL DoCUMENT - PLEASE PRINT LEGIBLY
Page 2 of ~ For lab Use Only
Lab No. '~:>ceo <(,
Accept Reject
.
I Project Name; DNS I ProjectLocation: Milwaukee, WI
Description : ·· · . . Volume I Area Comments/ Notes (as applicable)
~0 ~.;t T~-t ~'i:,"t-.c:..
I
~
SATURDAY SAMPLE DELIVERY- CALL TO SCHEDULE • Use this address for Saturday Delivery only: 4220 N. Santa Fe Ave., Oklahoma City, OK 73105-8517 • Mark Package "Hold for Saturday Pickup"
1 Family Dwelling SNIP Asbestos Inspection W:/Word/HMG/13 Projects/13-2000-399.3227
3227 North 25th Street December 23, 2013
Milwaukee, Wisconsin
Contract # 360-13-0745
11
IX. HMG CERTIFICATION
ASBESTOS INSPECTOR
STATE OF WISCONSIN
Dept. of lleahh Services
Demicca Andrea Marie Coe
1237 W Bruce St
Milwaukee WI 53204-12 18
ISO lbs 5' 0 I "
All-156385 Ex : 09/26/2014 09/081197 1 Female
Training due by: 09/26/20 14
ASBESTOS INSPECTION REPORT Job Site:
Fire Damaged 1 Family Dwelling
3310 North 301b Street
Milwaukee, Wisconsin
For:
City of Milwaukee Department ofNeighborhood Services
Attn: Marge Piwaron 841 North Broadway 1st Floor
Milwaukee, Wisconsin 53202-3613
HMG Report No.: 13-0105.3310 Contract No.: 360-13-0745
~~~ Dean Jacobsen Asbestos Inspector No. All - 14370
Prepared by:
HARENDA MANAGEMENT GROUP P. 0. Box 511305
New Berlin, Wisconsin 53151-2105
February 2013
P.O. Box 511305 ·New Berlin, Wisconsin 53151-2 105 · (414) 383-4800 · (414) 383-4805
TABLE OF CONTENTS
I. Introduction ......... .. ...... ........................................................... ........................... ...... . 2
II. Building Survey ........................ .... ............. ...... .... .................... .. ... ................... ........ 2
III. The Laboratory .. ........... ...... .. ... .... ............... ...... ............... .... .. .. ........ .... .................. ... 2 A. Method of Analysis
IV. Findings and Observations ................................ ....... ................... .. ....... ... ..... .... ... .... .3
V. Exclusions ................ ................... ..... ........................ ....... .. .. ....... ..... ............ .......... ... 6
VI. Limitations ....... ...... ............ ... .. .. .... ........... ........... .... .............. ....... ....... .. ............... .... . 6
VII. Pre-Demolition Environmental Checklist .. . .......... ..... . ... . ..... .. ...... .. . .. ..... . . 7
VIII. Laboratory Results ...................... .. ......................... .............................................. .. 11
IX. HMG Certifications ....................................... ....... ... ... ...... ............ .................... ..... 12
I family Dwelling Asbestos Inspection 3310 North 30"' Street Milwaukee. Wisconsin Contract# 360-Jl-0745
W:/Word/HMG/ 13 Projectsfl3·0105.33 10 february 19. 2013
HMG Project il 13-0105
I. INTRODUCTION
Harenda Management Group (HMG) was retained by the City of Milwaukee Department of Neighborhood Services to conduct an inspection for possible asbestos containing materials in the dwelling at 3310 North 30th Street, Milwaukee, Wisconsin.
The inspection included plaster, texture, linoleum, flue packing, drywall/joint compound, ceramic tile, ceiling tile, and window glazing compound to determine if asbestos containing materials were present within the space as required by US EPA NESHAP regulation 40 CFR 61 Subpart M
II. BUILDING SURVEY
Marge Piwaron, of the City of Milwaukee Department ofNeighborhood Services, authorized HMG to conduct a building survey and to analyze samples taken during the inspection.
On February 7, 2013, HMG conducted an asbestos inspection of a one family dwelling scheduled for mechanical demolition, located at 3310 North 30th Street, Milwaukee, Wisconsin. The inspection was conducted by Dean Jacobsen, Wisconsin License No. All- 14370.
The inspection was comprised of three elements:
1. A visual determination as to the extent of suspect materials within the building.
2. Sampling and documentation of observable suspect materials. Category I nonfriable materials were assumed to be asbestos containing and not sampled.
3. · Quantification of observable positive materials existing within the spaces.
The results of the survey integrated ~th the Polarized Light Microscopy with Dispersion Staining (PLMIDS) analysis of bulk samples taken are outlined in this document. If you have any questions please contact HMG at (414) 383-4800.
III. THELABORATORY
A. METHOD OF ANALYSIS
Analysis is performed by using the bulk samples for visual observation and slide preparation(s) for microscopical examination and identification. The slides are analyzed for asbestos (chrysotile, amosite, crodcidolite, anthophyllite, and actinolite/ tremolite), fibrous non asbestos constituents (mineral wool, paper, etc.), and nonfibrous constituents. Asbestos is identified by refractive indices (obtained by using dispersion staining),
1 Family Dwelling Asb<stos Inspection 33 10North 30"'Street Milwaukee, \Visconsin Contract # 360-13.()745
2 W:/Word!HMG/13 Projectsl13-0105.33 10 February 19. 2013
HMG Project ~ 13-0 I OS
morphology, color, pleochroism, birefringence, extinction characteristics, and signs of elongation. The same characteristics are used to identify the non asbestos constituents. The microscopist visually estimates relative amounts of each constituent using a stereoscope if necessary. The test results are based on a visual determination of relative volume of the bulk sample components. The results are valid only for the item tested. Current US EPA NESHAP regulations state asbestos materials means material containing more than 1% asbestos as determined using the method specified in Appendix E, Subpart E, 40 CFR Part 763 Section I, Polarized Light Microscopy. Refer to 29 CFR 1926.1101 (Construction) and 29 CFR 1910.1001 (General Industry) for specific OSHA requirements.
IV. FINDINGS AND OBSERVATIONS
The materials identified as suspect asbestos containing materials (ACM) include plaster, texture, linoleum, flue packing, drywall/joint compound, ceramic tile, ceiling tile, and window glazing compound. These materials were sampled and the following results were noted:
Sample# Location and Description
1-3310 I '1 floor - front entry - top layer - brown and gray linoleum
2-33 IO 1 '' floor - front entry- bottom layer - tan linoleum
3-3310 I st floor - bathroom - top layer - brown and red linoleum
4-3310 1 '' floor- bathroom- under plywood- tan and gray linoleum
5-3310 Basement - on north side of chimney- top layer - gray flue packing
6-3310 Basement- on north side of chimney - bottom layer - white flue packing
7-3310a Basement - on east and west sides of chimney -light gray flue packing
7-3310b Basement - on east and west sides of chimney -plaster
8-3310a 1st floor -kitchen- ceiling - plaster base coat 8-33 10b 1st floor - kitchen - ceiling -plaster skim coat 9-3310a 1 ' 1 floor - northeast bedroom - ceiling - plaster
base coat 9-3310b 1 ' ' floor- northeast bedroom- ceiling- plaster
skim coat 10-3310a 1 '1 floor -northwest bedroom - ceiling - plaster
base coat 10-3310b I '1 floor- northwest bedroom - ceiling - plaster
skim coat I l-3310a 1st floor - dining room- ceiling - plaster base
coat ll -33IOb 1 '' floor- dining room - ceiling - plaster skim
coat
1 Family Dwelling Asbestos Inspection 331 o Nonb >o" Street
3 Milwaukee, Wisconsin Contract # 3~ 13-0745
Results
Negative
Negative
Negative
Negative
Negative
Negative
Negative
Negative
Negative Negative Negative
Negative
Negative
Negative
Negative
Negative
Approximate Homogeneous Quantity Code
N/A MFLny
NIA MFLt
N/A MFLnr
N/A MFLty
NIA TFPy
N/A TFPw
N/A TFPy
N/A TFPy
NIA SPl N/A SPl N/A SPl
N/A SPl
N/A SPl
NIA SPl
NIA SPl
NIA SPl
W:/Word/HMG/13 Projects/13..0105.3310 February 19, 20 13
HMG Project# 13..0105
Sample# Location and Description
12-3310a I 51 floor - living room- south wall - plaster base coat
l2-3310b I'' floor - living room - south wall - plaster skim coat
13-3310 I'' floor- northeast bedroom- ceiling- texture 14-3310 I 51 floor - northwest bedroom - ceiling - texture 15-3310 I 51 floor- living room- ceiling- texture 16-33 10a Basement - south wall - plaster #2 16-3310b Basement - south wall - plaster #2 skim coat 17-3310a Basement - north wall - plaster #2 17-3310b Basement - north wall - plaster #2 skim coat 18-3310a Basement - east wall - plaster #2 18-3310b Basement - east wall - plaster #2 skim coat 19-3310 151 floor - northeast bedroom - west wall -
texture #2 20-3310 151 floor- northwest bedroom- south wall-
texture #2 21-3310 151 floor - dining room - north wall - texture #2 22-3310 151 floor - northeast bedroom- north wall -
drywall 23-3310 1 '' floor- bathroom - south wall - drywall 24-3310 151 floor - front entry -north wall - drywall
25-3310a 151 floor -bathroom - on wall near floor - gray ceramic tile
25-33 10b 151 floor -bathroom- on wall near floor - gray ceramic tile grout
26-3310 1 ' ' floor - bathroom - on east and west walls -cream ceramic tile
27-3310a 151 floor - bathroom - on northeast corner wall -red and yellow ceramic tile
27-3310b 151 floor - bathroom - on northeast corner wall -red and yellow ceramic tile !!rout
28-3310 151 floor- dining room- 1' x 1' ceiling tile 29-3310 151 floor- living room - east side - 1' x 1' ceiling
tile 30-3310 151 floor - living room - west side- 1' x 1' ceiling
tile 31-3 310 I 51 floor - dining room- on east wall- white and
red ceramic tile 32-3310 I 51 floor- bathroom - ceiling east side - texture
#3 33-3310 I'' floor- bathroom - ceiling center - texture #3 34-3310 151 floor - bathroom - ceiling west side - texture
#3 35-33 10 I 51 floor - living room - south window- glazing
compound 36-33 10 Quality Assurance/ Quality Control Sample of
SampJe 2-3310 37-3310 Quality Assurance/ Quality Control Sample of
Sample 3-3310
I Family Dwelling Asbestos Inspection 3310 Nonh 30lb Street
4 Milwaukee, Wisconsin Contnct N 360-13-0745
Results
Negative
Negative
Negative Negative Negative Negative Negative Negative Negative Negative Negative Negative
Negative
Negative Negative
Negative Negative Negative
Negative
Negative
Negative
Negative
Negative Negative
Negative
Negative
Negative
Negative Negative
Negative
Negative
Negative
Approximate Homogeneous Quantity Code
N/A SPI
N/A SPl
N/A STX N/A STX N/A STX NIA SPI2 N/A SPI2 N/A SP12 N/A SPI2 N/A SPI2 N/A SPI2 N/A STX2
N/A STX2
N/A STX2 N/A MDW
N/A MDW N/A MDW N/A MCTMy
N/A MCTMy
N/A MCTMc
N/A MCTMrl
N/A MCTMrl
NIA MSCT11 N/A MSCTil
N/A MSCT11
N/A MCTMwr
N/A STX3
N/A STX3 N/A STX3
N/A MPG
NIA QAQC
N/A QAQC
WJWord/HMG/ 13 Projects/13-0105.3310 February 19, 2013
HMG Project # 13-0105
Notes: N/A =Not Applicable Sq. Ft.= Square Feet
A ssume d c t a egory I N F . bl A b t C t . . M t . I on- na e s es os on ammg a ena: Floor Level Location Description Approximate Quantity
Roof Dwelling Asphalt Shingles & Flashing 1 SI/ 2Dd Dwelling Asphalt Shingle Siding
J Sl Kitchen/Bathroom Floor Tile & Mastic } St Front Entry/Dining Room/Bathroom Floor & Wall Mastic
Homogeneous Material Codes
SPI SPI2 STX STX2 STX3 MPG MFLny MFLt MFLnr MFLty MFLy MDW MCTMy MCTMc MCTMrl MSCTll TFPw TFPy TFPylight QAIQC
Plaster Plaster #2 Texture Texture #2 Texture #3 Window Glazing Compound Brown & Gray Linoleum Tan Linoleum Brown & Red Linoleum Tan & Gray Linoleum Gray Linoleum DrywalVJoint Compound Gray Ceramic Tile Cream Ceramic Tile Red & Yellow Ceramic Tile 1' x I ' Ceiling Tile White Flue Packing Gray Flue Packing Light Gray Flue Packing Quality Assurance/Quality Control Sample
950 Sq. Ft. 1,300 Sq. Ft. 580 Sq. Ft. 180 Sq. Ft.
Note#l: Category I - Non-Friable Asbestos Containing Materials may become friable during mechanical demolition activities or maybe considered friable prior to demolition activities due to its current condition.
Note#2: If additional materials are discovered during demolition that are not listed above they are to be assumed to be asbestos containing.
Note#3: A copy of this report should be transmitted to the demolition contractor.
I Family Dwelling AsbeSios Inspection 33 10 Nonh 30~ Street Milwaukee, Wiscoruin ConlraCI # 360-13-0745
5 W:/WordiHMG/13 Projecu/13-0105.3310 February 19, 20\3
HMO Projecl # 13-0105
V. EXCLUSIONS
No access to 2 nd floor and attic. Roof visible only from ground. No visible or accessible areas or material were excluded from this scope of work.
HMG is not and shall not represent the building owner as its agent or representative for the purpose of the US EPA/NESHAP and/or the WDNRINR447 regulations, as owner/ operator.
This report represents the condition ofthe building and its visible/accessible suspect asbestos containing materials at the date and the times of the onsite inspection. Hidden materials or those materials that could be present at the point of inspection, over and above those stated in the inspection report, are the responsibility of the building owner and the demolition contractor.
VI. LIMITATIONS
The care and skill given to our procedures insures the most reliable test results possible. HMG utilizes Schneider Laboratories for our Polarized Light Microscopy, unless otherwise specified by the client. The findings and conclusions ofHMG represent our professional opinions extrapolated from limited data. Significant limited data is gathered during the course of the preliminary asbestos specific site assessment. No other warranty is expressed or implied. Prior to any abatement or renovation activities, it is recommended that HMG be provided the opportunity to review such plans in order that the inspection and assessments contained herein are properly interpreted and implemented.
This report and the information contained herein are prepared for the sole and exclusive use and possession of the City of Milwaukee Department of Neighborhood Serv{ces. No other person or entity may rely on this report or any information contained herein. Any dissemination of the Report or any information contained herein is strictly prohibited without prior written authorization from Harenda Management Group.
I Family Dwelling Asbestos Inspection 3310 Nonh 30~ Street Milwaulcee, Wisconsin Contract N 360-13~745
6 W:JWord/HMG/ 13 Projects/13~105.3310
Fcbru..-y 19. 2013 HMG Project# 13·0105
VII. PRE-DEMOLITION ENVIRONMENTAL CHECKLIST
1 Family Dwelling Asbestos Inspection 3310 Nonh 301b Str~t ~ii.lwaukee. Wis.consin Contract# 360-13-0745
7 W:/Word/HMG/13 Projects/13-0105.3310 febtuaiY 19, 2013
HMG Project II 13-0105
This guide lists materials and products commonly found in buildings with examples. It is not intended as a substitute for reading the rules and statutes and making your own independent determination of their applicability to your demolition project. These examples presented here do not represent an exhaustive listing of types of materials that may be required to be removed from the building prior to demolition.
ASBESTOS Persons conducting inspections for asbestos must hold a valid asbestos inspector certification card issued by the State of Wisconsin, Dept. of Health & Family Services. Please follow the Asbestos Inspection and Sampling Protocol for Buildings to be Demolished or Renovated.
CFCs and HALONS Equipment that may contain CFCs and Halons:
N/A Air Conditioners (rooftop, room, and central)
N/ A Dehumidifiers
N/ A Heat Pumps
2 Refrigerators, Freezers, Chillers - Kitchen, Basement
N/A Vending Machines, Food Display Cases
N/A Walk-in Coolers
NIA Water Fountains (bubblers)
N/ A Fire Extinguishers (both portable and installed HALON suppression systems)
N/A Water Coolers
LEAD Lead or Lead Based Paint (LBP) is common in many older buildings. When recycling construction and demolition debris, be aware that wood containing lead paint may not be chipped and spread for landscaping. State law also prohibits the sale or transfer of any fixture or other object containing LBP that might be placed upon any surface of a dwelling, which is ordinarily accessible to children.
I Family Dwelling Asbestos Inspection 3310 Nonh 30" Street MHwaukee, Wisconsin Contract 11360-13..0745
8 W:/Word.IHMG/1 3 Projects/13-0105.3310 Februa!)' 19, 2013
HMG Project II 13..0!05
MERCURY Products that may contain mercury:
LIGHTING 3
NIA
Fluorescent Lights - Basement
High Intensity Discharge -Metal Halide -High Pressure Sodium -Mercury Vapor
NIA Neon
Nl A Switches for lighting using mercury relays -Look for any control associated with exterior or automated lighting systems such as "Silent" wall switches.
HVAC Check thermostats and any control associated with air handling units for switches containing mercury.
HEATING, VENTILATING AND AIR CONDITIONING SYSTEMS
Nl A Old Thermostats
N/ A Aquastats
N/ A Firestats
N/ A Manometers
N/ A Thermometers
BOILERS, FURNACES, HEATERS AND TANKS - 1 Furnace in Basement
N/ A Mercury Flame Sensors by pilot lights
Nl A Manometers, Thermometers, Gauges
N/ A Pressure-trol
N/ A Float or Level Controls
N/ A Space Heaters
I Family Dwelling Asbestos Inspection 33 10 Nonb 30" Street Milwaukee, \Visconsin Contract# 360·13.0745
9 W:/Word/HMG/1 3 Projec1SII3.0105.3310 February 19, 2013
HMGProject # 13.0105
ELECTRICAL SYSTEMS
Nl A Load Meters and Supply Relays
Nl A Phase Splitters
Nl A Microwave Relays
Nl A Mercury Displacement Relays
PCBs For electrical devices manufactured prior to 1987, it is safe to assume that they contain PCBs and should be managed accordingly. Most equipment manufactured after this time will say "PCB Free". The following is a list of areas in a building were PCBs may be found:
NIA Transformers
NIA Capacitors (appliances, electronic equipment)
Nl A Heat Transfer Equipment
3 Light Ballasts - Basement
NIA Specialty Paints (such as for swimming pools or other industrial applications)
NIA Sumps or Oil Traps (in maintenance and industrial facilities)
OTHER ENVIRONMENTAL ISSUES
N/A Hazardous Waste
NIA Oil Tanks
NIA Well Abandonment
Nl A Junk Auto Tires
NIA Junk Vehicles
* 1 Gas Meter & 5 Gallons Paint in Basement
I Family Dwelling Asbestos Inspection 3310Nortb 30., Street Milwaukee, Wisconsin Contract ;, 360-13-0745
10 W:/Word/HMG/13 Projects/13-0105.33 10 February 19, 2013
HMG Project# 13-0105
I family Dwelling Asbestos Inspection 33 10 Nonh 30~ Street Milwaukee, \Vuco!Uin Contract# 360-13-0745
VIII. LABORATORY RESULTS
11 W:/Word/HMG/ 13 Projects/13.0105.3310 february 19, 2013
HMG Project # 13-0105
02/14/2008 02:26 8046581708 SCHNEIDER LABS PAGE 01/10
SCHNEIDER LABORATORIES GLOBAL INCORPORATED
2512 W . Cary Street • Richmond, Virginia • 23220-5117 804-353-6778 • 800-785-LABS (5227) • (FAX) 804-359-1475 Over 25 Years of Excellence In Service and Technology
AIHA/ELLAP 100527,150/IEC 17025, NVLAP 101150-0, VELAP 460135, NYELAP/NELAC 11413
LABORATORY ANALYSIS REPORT Asbestos Identification by EPA Method1 600/R-93/116, EPA 600/M4-82-020
ACCOUNT#: 4001-13-847 CLIENT: ADDRESS:
Harenda Management Group 1237 West Bruce Street Milwaukee, WI 53204
PROJECT NAME: DNS JOB LOCATION: PROJECT NO.: 13-0105.3310 PONO.:
Client SLI Sample
Sample Sample/ Identification/
No. LayeriD Layer Name
1-3310 31776973
Layer1 : Flooring
Gray, Org.Bound/Fibrous
2-3310 31776974
Layer 1: Flooring Gray, Org.Bound/Fibrous
3-3310 31776975
layer 1: Flooring Red, Org.Bound/Fibrous
4-3310 31776976
Layer 1: Flooring Red, Org.Bound/Fibrous
5-3310 31776977
Layer1: Granular Material Gray, Granular
Totai Number of Pages In Report: 6
Using SLI A6
DATE COLLECTED:
DATE RECEIVED: DATE ANAL VZED: DATE REPORTED:
Sample Type:
2/11 /2013
2/11/2013 2/11/2013
BULK
PLM Analysis Results
Asbestos Rbers Other Materials
None Detected 40% CELLULOSE FIBER
60% NON FIBROUS MATERIAL
None Detected 40% CELLULOSE FIBER
60% NON FIBROUS MATERIAL
None Detected 40% CELLULOSE FIBER
60% NON FIBROUS MATERIAL
None Detected 40% CELLULOSE FIBER
60% NON FIBROUS MATERIAL
None Detected 100% NON FIBROUS MATERIAL
Results relate only to samples as received by the laboratory. Visit www.slabinc.com for current certifications.
Samples analyzed by the EPA Test Method are subject to the limitations of light microscopy including matrix interference. Gravimetric reduction and co"elative analyses are recommended tor all non-friable, organically bound materials. This method has a reporting limit of 1% or greater. Visual estimation contains an inherent range of uncertainty. This report must not be reproduced except in full with the approval of the lab, and must not be used to claim NVLAP or other gov't agency endorsement. The EPA states that any asbestos found in vermiculite is a concern and the sample should be treated as asbestos containing material.
02/ 14/2008 02:25 8045581708 SCHNEIDER LABS PAGE 02/10
Account - Workorder 4001-13-847 (Continued) Page 2 (Continued)
Client SLI Sample Sample Sample/ Identification/ PLM Analysis Results No. LayeriD Layer Name Asbestos Fibers Other Materials
6-3310 31776978
Layer 1: Powdery Material None Detected 4% CEU.ULOSE FIBER
White, Powdery 96% NON FIBROUS MATERIAL
7-3310 31776979
Layer1: Plaster None Detected 100% NON FIBROUS MATERIAL
Gray, Granular
Layer 2: Skim Coat None Detected 100o/., NON FIBROUS MATERIAL
White, Granular
8-3310 31776980
Layer 1: Plaster None Detected 100% NON FIBROUS MATERIAL
White, Granular
Layer 2: Skim Coat None Detected 100"k NON FIBROUS MATERIAL
White, Granular
9-3310 31776981
Layer 1: Plaster None Detected 100"k NON FIBROUS MATERIAL
Gray, Granular
Layer 2: Skim Coat None Detected 100"k NON FIBROUS MATERIAL
White, Granular
10-3310 31776982
Layer 1: Plaster None Detected 100% NON FIBROUS MATERIAL
Gray, Granular
Layer 2: Skim Coat None Detected 100% NON FIBROUS MATERIAL
White, Granular
11-3310 31776983
Layer 1: Plaster None Detected 100% NON FIBROUS MATERIAL
Gray, Granular
Layer 2: Skim Coat None Detected 100"k NON FIBROUS MATERIAL
White, Granular
Total Number of Pages In Report: 6
Results relate only to samples as received by the laboratory. Visit www.slabinc.com for current certifications.
Samples analyzed by the EPA Test Method are subject to the limitations of light microscopy including matrix interference. Gravimetric reduction and correlative analyses are recommended for all non-friable, organically bound materials. This method has a reporting limit of 1% or greater. Visual estimation contains an inherent range of uncertainty. This report must not be reproduced except in full with the approval of the lab, and must not be used to claim NVLAP or other gov't agency endorsement. The EPA states that any asbestos found in vermiculite is a concern and the sample should be treated as asbestos containing material.
02/14/2008 02:26 8046581708 SCHNEIDER LABS PAGE 03/10
Account - Workorder 4001-13-847 (Continued) Page 3 (Continued)
Client SLJ Sample
Sample Sample/ Identification/ PLM Analysis Results No. LayeriD Layer Name Asbestos Fibers Other Materials
12-3310 31776984
Layer 1: Plaster None Detected 100% NON FIBROUS MATERIAL
Gray, Granular
Layer 2: Skim Coat None Detected 100% NON FIBROUS MATERIAL
White, Granular
13-3310 31776985
Layer 1: Granular Material None Detected 100"/o NON FIBROUS MATERIAL
Gray, Granular
14-3310 31776986
Layer 1: Granular Material None Detected 100"/o NON FIBROUS MATERIAL
Gray, Granular
15-3310 31776987
Layer 1: Granular Material None Detected 100"/o NON FIBROUS MATERIAL
Gray, Granular
16-3310 31776988
Layer 1: Plaster None Detected 1200% NON FIBROUS MATERIAL
Gray, Granular
Layer 2: Skim Coat None Detected 100"/o NON FIBROUS MATERIAL
White, Granular
17-3310 31776989
Layer 1: Plaster None Detected 10% NON FIBROUS MATERIAL
Gray, Granular
Layer 2: Skim Coat None Detected 100% NON FIBROUS MATERIAL
White, Granular
18-3310 31776990
layer 1 : Plaster None Detected 100% NON FIBROUS MATERIAL
Gray, Granular
Total Number of Pages In Report: 6
Results relate only to samples as received by the laboratory. Visit www.slabinc.com for current certifications.
Samples analyzed by the EPA Test Method are subject to the limitations of light microscopy including matrix interference. Gravimetric reduction and correlative analyses are recommended tor all non-trtabfe, organically bound materiafs. This method has a reponing limit of 1% or greater. Visual estfmation contains an inherent range of uncertainty. This report must not be reproduced except in full with the approval of the lab, and must not be used to claim NVLAP or other gov~ agency endorsement. The EPA states that any asbestos found in vermiculite is a concern and the sample should be treated as asbestos containing material.
02/14/2008 02:26 8046581708 SCHNEIDER LABS PAGE 04/ 10
Account- Workorder 4001-13-847 {Continued) Page 4 {Continued)
Client SLI Sample
Sample Sample/ Identification/ PLM Analysis Results No. LayeriD Layer Name Asbestos Fibers Other Materials
Layer 2: Skim Coat None Detected 100% NON FIBROUS MATERIAL
White, Granular
19-3310 31776991
Layer 1: Granular Material None Detected 100% NON FIBROUS MATERIAL
Beige/Black, Granular
20-3310 31776992
Layer 1: Granular Material None Detected 100% NON FIBROUS MATERIAL
Beige/Black, Granular
21-3310 31776993
Layer 1: Granular Material None Detected 100% NON FIBROUS MATERIAL
Beige/Black, Granular
22-3310 31776994
Layer 1: Powdery Material None Detected 4% CELLULOSE FIBER
White, Powdery 96% NON FIBROUS MATERIAL
23-3310 31776995
Layer 1: Powdery Material None Detected 4% CELLULOSE FIBER
White, Powdery 96% NON FIBROUS MATERIAL
24-3310 31776996
Layer 1: Powdery Material None Detected 4% CELLULOSE FIBER
White, Powdery 96% NON FIBROUS MATERIAL
25-3310 31776997
Layer 1: Ceramic Tile None Detected 100% NON FIBROUS MATERIAL
White, Hard
Layer 2: Granular Material None Detected 100% NON FIBROUS MATERIAL
Gray, Granular
26-3310 31776998
Layer 1: Ceramic Tile None Detected 100% NON FIBROUS MATERIAL
White, Hard
Total Number of Pages In Report: 6
Results relate only to samples as received by the laboratory. Visit www.slabinc.com for current certifications.
Samples analyzed by the EPA Test Method are subject to the limitations of light microscopy including matrix interference. Gravimetric reduction and correlative analyses are recommended for aff non-friable, organically bound materials. This method has a reporting limit of 1% or greater. Visual estimation contains an inherent range of uncertainty. This report must not be reproduced except in full with the approval of the lab, and must not be used to claim NVLAP or other goVt agency endorsement. The EPA states that any asbestos found in vermiculite is a concern and the sample should be treated as asbestos containing material.
02/ 14/2008 02:26 8046581708 SCHNEIDER LABS PAGE 05/10
Account- Workorder 4001-13-847 (Continued) Page 5 (Continued)
Client SLI Sample
Sample Sample/ Identification/ PLM Analysis Results No. LayeriD Layer Name Asbestos Fibers Other Materials
27-3310 31776999
Layer 1: Ceramic Tile None Detected 100% NON FIBROUS MATERIAL
Red, Hard
layer 2: Grout None Detected 100o/o NON FIBROUS MATERIAL
Gray, Granular
28-3310 31777000
layer 1: Ceiling Tile None Detected 90% CELLULOSE FIBER
Brown, Fibrous 10% NON FIBROUS MATERIAL
29-3310 31777001
Layer 1: Ceiling Tile None Detected 90% CELLULOSE FIBER
Brown, Fibrous 10% NON FIBROUS MATERIAL
30-3310 31777002
Layer 1: Ceiling Tile None Detected 90% CELLULOSE FIBER
Brown, Fibrous 10% NON FIBROUS MATERIAL
31-3310 31777003
Layer 1: Ceramic Tile None Detected 100% NON FIBROUS MATERIAL
White, Hard
32-3310 31777004
Layer 1: Mastic None Detected 100% NON FIBROUS MATERIAL
Tan, Soft
33-3310 31777005
Layer 1: Granular Material None Detected 100% NON FIBROUS MATERIAL
Gray, Granular
34-3310 31777006
Layer 1: Granular Material None Detected 100% NON FIBROUS MATERIAL
Gray, Granular
Total Number of Pages In Report: 6
Results relate only to samples as received by the laboratory. Visit www.slabinc.com for current certifications.
Samples analyzed by the EPA Test Method are subject to the limitations of light microscopy including matrix interference. Gravimetric reduction and correlative analyses are recommended for all non-friable, organically bound materials. This metflod has a reporting limit of 1% or greater. Visual estimation contains an inherent range of uncertainty. This report must not be reproduced except in full with the approval of the lab, and must not be used to claim NVLAP or other gov't agency endorsement. The EPA states that any asbestos found in vermiculite is a concern and the sample should be treated as asbestos containing material.
02/14/2008 02:26 8046581708
Account- Workorder 4001~13-847 (Continued}
Client SLI Sample
Sample Sample/ Identification/
No. LayeriD Layer Name
35-3310 31777007
Layer 1 : Granular Material Gray, Granular
36-3310 31777008
layer 1 : Flooring Beige, Org.Bound/Fibrous
37-3310 31777009
Layer 1 : Flooring Red, Org.Bound/Fibrous
Analyst: Ali Musa
Total Number of Pages In Report: 6
SCHNEIDER LABS PAGE 06/10
Page 6 (Continued}
PLM Analysis Results Asbestos Fibers Other Materials
None Detected 100% NON FIBROUS MATERIAL
None Detected 40% CELLULOSE FIBER
60% NON FIBROUS MATERIAL
None Detected 40% CELLULOSE ABER
60% NON FIBROUS MATERIAL
<"'"'i=-- ... -
Reviewed By: Samani Abdelfadiel, Analyst
Results relale only to samples as received by the laboratory. Visit www.slabinc.com for current certifications.
Samples analyzed by the EPA Test Method are subject to the limitations of light microscopy including matrix interference. Gravimetric reduction and correlative analyses are recommended for all non-friable, organically bound materials. This method has a reporting limit of 1% or greater. Visual estimation contains an inherent range of uncertainty. This report must not be reproduced except in full with the approval of the lab, and must not be used to claim NVLAP or other gov't agency endorsement. The EPA states that any asbestos found in vermiculite is a concern and the sample should be treated as asbestos containing material.
02/14/2008 02:26 8046581708 SCHNEIDER LABS PAGE 07/10
woiirliiliSMIWIII&IDI -
SCHNEIDER LABORATORIES, INC. 2512 West Cary Street, Richmond, Virginia 23220-5117
v . \ 9 3 6 \ 9 3 6 6 9 91
804-353-6778 • 800-785-LA.BS (5227) • Fax 804-359-1475
www.slabinc.com e-mail: [email protected]
Submitting L, Lab
lh~l-11-" ~\l .... _____________
Uae-Co. arenda Manaaament Grouo WO# -----
ACCUI I Phone# 414-383-4800 P.O. Box 511305 t-axlJ
& 414-3834805 New Berlin. WI 53151 4001 E-mail [email protected]
Project Name: PNS Sl?_ec/altnstructions [include requests for special reportJng or data packages
ProJect Location: DO NOT ANALYZE MASTICS
J>rolect Number: ~3-0105. 3?LO
.,ONumber: State Of Collec:tlon ~
. ' -Tum Around"11me .:Matrix I Sample-l\rpe(SeleCt ONE} Teate I AnlilvtasiSelect ALL.that Appl'i) .. ' . -0 2 hours• AI/ samples on form should be of SAME Asbestos Air·~ Fiber Counts • Asbeatbs Bulk f'Asb 10 Metala·Totai ·Conc:
maflix typo Use additional forms as needed. Osameday• 0PCM (NIOSH 7400) (&I PLM (EPA600, 1982) 0Lead
0 1 business day• 0Air OSolid 0TEM (AHERA) 0 PLM (EPA Point Count) 0 RCRA Metals
0 2 business day• 0Aqueous 0Wasle 0TEM (EPA Level II) 0 PLM (Qualitative only) 0
(g) 3 business daya• fig Bulk 0 Wastewater 'n 0 NYELAP 198.1/.4/.6 :n := -
0 5 business days• 0 Hi-Vol Fllter(PM10) 0Water,Drinking ,. Mlacellaneoas Testa • 0 CAELAP (EPA Interim) . Metala-Extract
0 Full TCLP (10d) 0 Hi-Vol F~ter (TSP) 0 Compliance OTotal Oust (NIOSH 0500) 0 TEM (Ctla1field) OTCLP /Lead
0VVeekand• oou 0Wpe OResp. Oust(NIOSH 0600) In 0 TCLP I RCRA Metals
• not avaiable for all teats 0Paint 0 Wpe, Composite 0Silica- FTIR (NIOSH 7602) FOR ASBESTOS AIR: [OTCLP I Full (w/ omanics) . Schedule =h OtfiWJles, mulfj. 0Siudge 0 0Silica- XRD (NIOSH 7500) TYPE OF RESPIRATOR ·., .. Others ., r
metals & w-end tats in 0Sotl 0 lo 0 advance. USED:
Date Time Sample Identification IMped Type1 ..
Time2 AowRate3 Totar-4
Sample# Sampled Sampled (_e.g. Employee SSN Bldg, Material) Area(ft") A.BP.E Start Stop Start Step Air Vol
( ~?~o Q-33£o
f3~33£o
lcr-~(o
5-~
C.c33lo 7-3:Xv
~-33<.-o
)-~o
{'> -330
I( ~33£-o
12. -~3t0 1Type: A=area B=blank P=personal E=excurslon 2Beglnnlng/End of Sample Period 3Pump Calibration In Litera/Minute 4volume In Liters [tlme In min • flow In Umin]
~ampled by ~elinquished to lab by of3 Fx:;:-0UPS
~ME ~ME Dean Jacobsen 0 USM
~IGNATURE~ 0 HO
SIGNATURE 0 DB
DATE/TIME f>ATEITIME 2lalj3 jz'QQ lbr~ ,_:::::;;?.,..., -:h.J m v 10 Samole retum reouested D Ambient temp D Ice oc PH Cl OR 11l6DX ., I '-
02/14/2008 02: 26 8046581708 SCHNEIDER LABS PAGE 08/ 10
. WOL.abel:
SCHNEIDER LABORATORIES, INC. 2512 West Cary Street, Richmond, Virginia 23220-5117
804-353-6778 • 800-785-LABS (5227) • Fax 804-359-1475
www.slabinc.com e-mail: [email protected]
Submitting~~ LaD Uae-
Co. arende Meneaement Orouo WO# 1 Acct# Phone# 414-383-4800
IP.o. Box 511305 fax# & 414-383-4805
New Berlin WI 53151 4001 E-mail [email protected]
Prolect Nama: DNS Soeclsllnstructions [include reauests for soeclsl reoortinCl or data oackBCles
ProJect Location: bb NOT ANALYZE MASTICS
Pn>"ect Number: 13-0105. 53(0 PO Number:
State Of Collection ~
Matttx I Sam. ole Tv.;. fSelecf ONE1 -
Teets tA~~a'(_Select ALL-thalAoolvl ~ '""' ... ~.~
Tum Around 11me. . . 02hours• All samples on fonn should be of SAME AsbestO. 'Air I Fiber Counta ':ASbeslo$ Buill/ Aab.ID Met.ala·TotatCOnc'.
ms/rix l)tDe Use additional fonns ss ne&ded. 0PCM (NIOSH 7400) I8J PLM (EPA 600, 1982) 0Lead Osameday•
0 1 business day• OAir 0Solid OrEM {AHERA) 0 PLM (EPA Point Count) 0 RCRA Metals
0 2 business day• 0Aqueous 0Waste QTEM (EPA level II) 0 PLM (Qualitative only) 0
l8J 3 business days• IE) Sulk 0 Wastewater lo 0 NYELAP 198.1/.4/.6 lo Mlaceilaneouadesta
' J ,.,
0 5 business days• 0 Hi-Vol Filter (PM10) 0 Water, Drinking 0 CAELAP (EPA Interim) Metals-Extract
0 Full TCLP {10d) 0 Hi-Vol Filter {TSP) 0 Compliance OTolal Dust (NIOSH 0500) 0 TEM {Chatfield) OTCLP/lead
0Weel\cnd* 00fl 0Wpe OResp. Dust {NIOSH 0600) lo 0 TCLP I RCRA Metals
• not available for all tests 0Paint 0 'Mpe, Composite 0Salca- FTIR {NIOSH 7602) FOR ASBESTOS AIR: IDTCLP I Futl (w/ Qrganics)
0Siudge D 0Silica- XRD (NIOSH 7500) .. - ~ J , .. Scheduletwh orvanles, multi- TYPE OF RESPIRATOR .Othere
metals & wHictnd -In O soi 0 !o 0 adv.nce. USED:
Date Time Sample Identification Wiped Type1 Time2 Flow Rate3 Totar-4
Sample# Sampled Sampled (e.g. Eml)loy_ee SSN Bldg._Materi<!l) Area (ft2) IABPE Start SIQQ Start Stoo Air Vol
{3--:,3£~
~~ -33fo (5'-~
{(, -33to
{1-~\)
('e-33fo
/'7-33t-u
~-~CO
d\~
~~33ro
(;8..-:f>m
61-f-33CD 1Type: A=area B=blank P.personal E• excurslon 2Beglnnlng/End of Sample Period 3Pump Calibration in Liters/Minute "volume In Litera [time In min • flow In Umln)
Sampled by Relinquished to lab by ~ CJ UPS
NAME NAME ~nJacobsen 0 USM 0 HD
SIGNATURE SIGNATURe0~ ct• DATEI11ME ./2/8£:13 jZ·QQ lk/~.~~ : ~-,~ ~ DATE111ME
intemal~laU~ ~~ OOCtJ 2. J Sam ole return reauested D Ambient temo D Ice oc pH Cl _OR l:lJ.5 OX Y"-._ \. ~- _j
02/14/2008 02:26 8046581708 SCHNEIDER LABS PAGE 09/ 10
WOLabel:
SCHNEIDER LABORATORIES, INC. 2512 West Cary Street, Richmond, Virginia 23220-5117
804-353-6778 • 800-785-LABS (5227) • Fax 804-359-1475
www.slabinc.com e-mail: [email protected]
Submitting L, LaD Uaa-
Co. arenda Manauament Group_ WO#
A"tiF Phone# 414-383-4800 P.O. Box 511305 fUll'
& 414-383-4805 New Berlht WI 53151 4001 E-mail [email protected]
ProJect Name: DNS S_p_ecia/lnstructions [Include reqpests for special reporting or data packages
Prolect Location: 00 NOT ANALYZE MASTICS
ProJect Number: 13-a1os. ~?c.o
PO Number: Stata Of Collection ~~
Tum Around Tlme- Matrhd Samola Tvoe.fS;lecit ONE}. .
Testa·/ AnatvtJ f&iiect ALL that AppiV} - - ~ ....
.,. ..... . . -02hours• All samples on form should be of SAME . Asbestos Air I Flber.Courtta Asbastoa.Bulk /:Asb ID- ..., Metals-Total cone. ,
matrix type Use additional forms as needed. osameday• 0PCM (NIOSH 7400) 18) PLM (EPA 600, 1982} 0Lead
0 1 business day• 0Air Osolid 0TEM {AHERA) 0 PLM (EPA Point Count) 0 RCRA Metals
0 2 business day• QAqueous owaste 0TEM (EPA level II) 0 PLM (Qualitative only) 0
~ 3 business days• IBJ Bulk 0 Wastewater 0 0 NYELAP 198.1/.4/.6 lo i'
MIBcellaneou. Testa Metala-Ex&-;.ct 0 5 business days• 0 HI-Vol Fllter{PM10) 0Water,Drinking 0 CAELAP (EPA Interim) ' ' D Full TCLP (10d) D HI-Vol Filter (TSP) 0 Compliance 0Total Dust (NIOSH 0500) 0 TEM (Chatfield) OTCLPILead
0Weekend' 00il 0 VVIpa 0Resp. Dust(NIOSH 0600) In 0 TCLP I RCRA Metals
• not avaUable for all tests 0 Paint 0 'Mpe, Composite 0Silica - FTIR {NIOSH 7602) FOR ASBESTOS AIR: n TCLP I Full (w/ Otllanics) -\'::;_._,..;.)
. ,rl Se/ledul• rwh otr~anks, multi- 0Siudge 0 0Silica • XRD (NIOSH 7500) TYPE OF RESPIRATOR ... OtherS.:'-~s & weekend t~os~sln
IDsoil D IO 0 •dvance. USED:
Date Time Sample Identification Vlliped Type1 limel · FlowRate3 Total4
Sample# Sampled Sampled (e.g. Employee, SSN BldQ. MateriaO Area (ft') ABP,E Start Stop Start Stop Air Vol
~5-?x\)
~h-~o 'CX7-~-o
~~-~
~~?,)(.'0
?o-~3t-o
~( -~£'0
~~-~10
33-~
~--35-o 2f5~3:x~
~-3Yo 1Type: A" area B" blank P>=personat E=excurslon 2BeglnnlngJEnd of Sample Period 3Pump Calibration In U1era/Minute 4volume In Liters [time In min • flow In Umin]
Sampled by ~elinqulshed to lab by ~ 0 UPS
NAME ~E Dean Jacobsen 0 USM OHD
SIGNATURE ~!GNAT~ 0 DB
c:tc.rc::; DATE/TIME pATE/TIME -------;8/jJ :1Z·QQ l~ \ ' linued lnte2.,h!n ;;,lr~~~s oaoe 2. ID Samole retum reouested D Ambient temp D Ice °C pH Cl ORr::vrDX . ... .,_ I - /
02/14/2008 02: 25 8045581708 SCHNEIDER LABS PAGE 10/ 10
WOUibel:
SCHNEIDER LABORATORIES, INC. 2512 West Cary Street, Richmond, Virginia 23220-5117
804-353-6778 • 800-785-LABS (5227) • Fax 804-359-1475
www.slabinc.com e-mail: [email protected]
Submitting L, UID Use-
Co. arenda Manaaemant Grouo WOtJ
Ac:ct# Phone# 414-383-4800 P.O. Box 511305 t'Uif
& 414-383-4805 New Bertin WI 531!51 4001 E-mail [email protected]
E>rolect Name: ioNS Special Instructions {Include reQuests for special reportinq or data 11Bcksqes
ProJect Location: DO NOT ANALYZE MASTICS
ProJect Number: ~3-0105. 3x-a Po Number: State Of Collection Wl
·' . Matrla /-Sample TvpefSei;J ON 'a Teats/ Analvtu (Select All.that A~Divl -· . " . :rum'Around,Ttme . . . - - . _,
02 hours• All samples on form should be of SAME Aebeatcis Air I liiber-cdunta - · Asbenos Bulk:/.A:ab 10 -· . Matals•Totafc(:()nc.. . maMx ty_po Use addffjonal forms as naedad.
osarneday• 0PCM (NIOSH 7400) lEJ PLM (EPA 600, 1982) 0Lead
0 1 business day• O Air OSolid 0TEM (AHERA) 0 PLM (EPA Point Count) 0 RCRA Metals
O 2 business day' 0Aqueous 0Waste 0TEM (EPA Level II) 0 PLM (Qualitative only} n IEJ 3 business days• ~Bulk 0 Wastewater In 0 NYElAP 198.1/.4/.6 lD 0 5 business days• 0 Hi-Vel FOter (PM10) QWater,Orinking .; Mlec:ellaneous-Taata 0 CAELAP (EPA Interim) h • Metals-E'rtrad . 0 Full TCLP (10d} 0 Hi-Vol FHter (TSP) O Compliance OTotal Oust (NIOSH 0500) 0 TEM (Chatfield) O TCLP/ Lead
0Weekend' oon 0 Wipe OResp. Oust(NIOSH 0600} !0 0 TCLP I RCRA Metals
• not avaiable tor all tests 0Painl 0 Wipe, Compostte 0Silice- FTlR (NIOSH 7602) FOR ASBESTOS AIR: !n TCLP I FuN (w/ organics)
but~,. .. ~
Schedule rush Otflanlcs, mui!J. 0Siudge 0 QSaice - XRO (NIOSH 7500) TYPE OF RESPIRATOR !· -mml$ & weekend t.m in
DSoil 0 0 0 a<:Jv.nce. USED:
Date Time Sample Identification 'Mped Type1 Time2 Flow Ratel Totat4 SamPle# Sam'pfed Sampled (e.a. Emplovee SSN Biela. MateriaO Area (ft") ABP.E Start Stoo Start Stoo Air Vol
3?-?)t..,:)
1Type: A=area B=blank P=peraonal E=eacuralon 2Beglnning/End of Sample Period 3Pump Calibration In Liters/Minute 4volume In Liters [time In min • flow In UmlnJ
~ampled by ~elinquished to lab by 0 FX -0 UPS
~AME NAME Dean Jacobsen 0 USM
$~NAWRE a~ OHO
~!GNATURE oos
CJo/~ bATEmME DATE/TIME ·_. -- lZ'OQ
b~.lmenra~ ccn6n~~l. "'-J Sample return requested 0 Ambient temp 0 lee •c PH Cl DR[JSDX . 9fii1'D>n<Jiliol>s I"'Q6 2.
'\ .. ' c. _..,. r r_s
I Family Dwelling Asbestos Inspection 3310 Nonh 30" Street Milwaukee. Wisconsin Contract~ 360-13-0745
IX. HMG CERTIFICATION
12 W:/Word/HMGI13 Projects'I3-0I 05.3310 February 19, 2013
HMG Project# 13-0105
/ /
:izai!B>
;o.:srAt'EOF vm;c()NSIN
t;lepL--ef:Beab:b ~
~~ lW;JIS~~~~~Dr
P.O. Box 511305 · New Berlin, Wisconsin 53151-2105 · (414) 383-4800 · (414) 383-4805
ASBESTOS INSPECTION REPORT
Job Site:
One Family Dwelling
4629 North 30th
Street
Milwaukee, Wisconsin
For:
City of Milwaukee
Department of Neighborhood Services
Attn: Marge Piwaron
841 North Broadway 1st Floor
Milwaukee, Wisconsin 53202-3613
HMG Report No.: 13-2000-068.4629
Contract No.: 360-13-0745
________________________ Dean Jacobsen
Asbestos Inspector No. AII – 14370
Prepared by:
HARENDA MANAGEMENT GROUP
P. O. Box 511305
New Berlin, Wisconsin 53151-2105
July 2013
1 Family Dwelling Asbestos Inspection W:/Word/HMG/13 Projects/13-2000-068.4629
4629 North 30th
Street July 10, 2013
Milwaukee, Wisconsin
Contract # 360-13-0745
1
TABLE OF CONTENTS
I. Introduction ..............................................................................................................2
II. Building Survey .......................................................................................................2
III. The Laboratory .........................................................................................................2
A. Method of Analysis
IV. Findings and Observations .......................................................................................3
V. Exclusions ................................................................................................................5
VI. Limitations ...............................................................................................................5
VII. Pre-Demolition Environmental Checklist…………………………………………7
VIII. Laboratory Results .................................................................................................11
IX. HMG Certifications ...............................................................................................12
1 Family Dwelling Asbestos Inspection W:/Word/HMG/13 Projects/13-2000-068.4629
4629 North 30th
Street July 10, 2013
Milwaukee, Wisconsin
Contract # 360-13-0745
2
I. INTRODUCTION
Harenda Management Group (HMG) was retained by the City of Milwaukee Department
of Neighborhood Services to conduct an inspection for possible asbestos containing
materials in the dwelling at 4629 North 30th Street, Milwaukee, Wisconsin.
The inspection included plaster, texture, ceramic tile, linoleum, glazing compound,
drywall/joint compound, transite, paper insulation, tar paper, and blown in insulation to
determine if asbestos containing materials were present within the space as required by
US EPA NESHAP regulation 40 CFR 61 Subpart M.
II. BUILDING SURVEY
Marge Piwaron, of the City of Milwaukee Department of Neighborhood Services,
authorized HMG to conduct a building survey and to analyze samples taken during the
inspection.
On July 3, 2013, HMG conducted an asbestos inspection of a one family dwelling,
scheduled for mechanical demolition, located at 4629 North 30th
Street, Milwaukee,
Wisconsin. The inspection was conducted by Dean Jacobsen, Wisconsin License No.
AII – 14370.
The inspection was comprised of three elements:
1. A visual determination as to the extent of suspect materials within the
building.
2. Sampling and documentation of observable suspect materials. Category I
nonfriable materials were assumed to be asbestos containing and not
sampled.
3. Quantification of observable positive materials existing within the spaces.
The results of the survey integrated with the Polarized Light Microscopy with Dispersion
Staining (PLM/DS) analysis of bulk samples taken are outlined in this document. If you
have any questions please contact HMG at (414) 383-4800.
III. THE LABORATORY
A. METHOD OF ANALYSIS
Analysis is performed by using the bulk samples for visual observation and slide
preparation(s) for microscopical examination and identification. The slides are analyzed
for asbestos (chrysotile, amosite, crodcidolite, anthophyllite, and actinolite/ tremolite),
fibrous non asbestos constituents (mineral wool, paper, etc.), and nonfibrous constituents.
Asbestos is identified by refractive indices (obtained by using dispersion staining),
1 Family Dwelling Asbestos Inspection W:/Word/HMG/13 Projects/13-2000-068.4629
4629 North 30th
Street July 10, 2013
Milwaukee, Wisconsin
Contract # 360-13-0745
3
morphology, color, pleochroism, birefringence, extinction characteristics, and signs of
elongation. The same characteristics are used to identify the non asbestos constituents.
The microscopist visually estimates relative amounts of each constituent using a
stereoscope if necessary. The test results are based on a visual determination of relative
volume of the bulk sample components. The results are valid only for the item tested.
Current US EPA NESHAP regulations state asbestos materials means material containing
more than 1% asbestos as determined using the method specified in Appendix E, Subpart
E, 40 CFR Part 763 Section I, Polarized Light Microscopy. Refer to 29 CFR 1926.1101
(Construction) and 29 CFR 1910.1001 (General Industry) for specific OSHA
requirements.
IV. FINDINGS AND OBSERVATIONS
The materials identified as suspect asbestos containing materials (ACM) include plaster,
texture, ceramic tile, linoleum, glazing compound, drywall/joint compound, transite,
paper insulation, tar paper, and blown in insulation. These materials were sampled and
the following results were noted:
Sample # Location and Description Results Approximate
Quantity
Homogeneous
Code
1-4629a 1st floor – kitchen floor – top layer – beige
ceramic tile
Negative N/A MCTMe
1-4629b 1st floor – kitchen floor – top layer – grout Negative N/A MCTMe
2-4629 1st floor – kitchen – under plywood – white
linoleum
Negative N/A MFLw
3-4629 1st floor – kitchen closet – red linoleum Negative N/A MFLr
4-4629 1st floor – back entry – white and gray linoleum Negative N/A MFLwy
5-4629 2nd floor – bedroom – ceiling – texture Negative N/A STX
6-4629 2nd floor – bathroom – south wall – texture Negative N/A STX
7-4629a 1st floor – front entry – north wall – texture Negative N/A STX
7-4629b 1st floor – front entry – north wall – texture layer
2
Negative N/A STX
8-4629 2nd floor – south east room – tan and beige
linoleum
Negative N/A MFLte
9-4629a 2nd floor – bathroom floor – tan ceramic tile Negative N/A MCTMt
9-4629b 2nd floor – bathroom floor – grout Negative N/A MCTMt
10-4629 2nd floor – bathroom floor – under ceramic tile –
mortar
Negative N/A MCTMM
11-4629 2nd floor – bathroom – under plywood – cream
linoleum
Negative N/A MFLc
12-4629 1st floor – living room – north wall – texture #2 Negative N/A STX2
13-4629 1st floor – living room – south wall – texture #2 Negative N/A STX2
14-4629 1st floor – bedroom – west wall – texture #2 Negative N/A STX2
15-4629a 2nd floor – southeast room – north wall – joint
compound
Negative N/A MDW
15-4629b 2nd floor – southeast room – north wall – drywall Negative N/A MDW
16-4629a 2nd floor – bedroom – north wall – joint
compound
Negative N/A MDW
16-4629b 2nd floor – bedroom – north wall – joint
compound #2
Negative N/A MDW
16-4629c 2nd floor – bedroom – north wall – drywall Negative N/A MDW
1 Family Dwelling Asbestos Inspection W:/Word/HMG/13 Projects/13-2000-068.4629
4629 North 30th
Street July 10, 2013
Milwaukee, Wisconsin
Contract # 360-13-0745
4
Sample # Location and Description Results Approximate
Quantity
Homogeneous
Code
17-4629a 1st floor – utility room – east wall – joint
compound
Negative N/A MDW
17-4629b 1st floor – utility room – east wall – drywall Negative N/A MDW
18-4629a 2nd floor – bathroom – north wall – patch layer Negative N/A SPl
18-4629b 2nd floor – bathroom – north wall – plaster skim
coat
Negative N/A SPl
18-4629c 2nd floor – bathroom – north wall – plaster base
coat
Trace <1%
Chrysotile
N/A SPl
18-4629c POINT COUNT RESULT Negative N/A SPl
19-4629a 2nd floor – bedroom – west wall – plaster skim
coat
Negative N/A SPl
19-4629b 2nd floor – bedroom – west wall – plaster base
coat
Trace <1%
Chrysotile
N/A SPl
19-4629b POINT COUNT RESULT Negative N/A SPl
20-4629a 1st floor – kitchen – north wall – plaster skim coat Negative N/A SPl
20-4629b 1st floor – kitchen – north wall – plaster base coat Negative N/A SPl
21-4629 1st floor – living room – ceiling – texture #3 Negative N/A STX3
22-4629 1st floor – living room – ceiling – texture #3 Negative N/A STX3
23-4629 1st floor – living room – ceiling – texture #3 Negative N/A STX3
24-4629 2nd floor – exterior – south wall – transite siding Positive 30%
Chrysotile
400 Sq. Ft. MTP
25-4629 2nd floor – exterior – east wall – transite siding Positive 30%
Chrysotile
Reference
24-4629
MTP
26-4629 2nd floor – exterior – north wall – transite siding Positive 30%
Chrysotile
Reference
24-4629
MTP
27-4629 2nd floor – exterior – south wall – under transite
siding – paper insulation
Negative N/A MPI
28-4629 2nd floor – exterior – east wall – under transite
siding – paper insulation
Negative N/A MPI
29-4629 2nd floor – exterior – north wall – under transite
siding – paper insulation
Negative N/A MPI
30-4629a 2nd floor – exterior – under transite seams – tar
paper
Negative N/A MPT
30-4629b 2nd floor – exterior – under transite seams – tar Negative N/A MPT
31-4629 1st floor – living room – on window – glazing
compound
Negative N/A MPG
31-4629 1st floor – utility room – on floor – blown in
insulation
Negative N/A MBI
33-4629 Quality Assurance/Quality Control sample of 3-
4629
Negative N/A QA/QC
Notes: N/A = Not Applicable
Ln. Ft. = Linear Feet
Assumed Category I Non-Friable Asbestos Containing Material:
Floor Level Location Description Approximate Quantity
Roof Building Asphalt Shingles & Flashing 500 Sq. Ft.
1st Kitchen/Stair/Back Entry Floor Tile & Mastic 190 Sq. Ft.
2nd Bathroom/Closets Floor Tile & Mastic 110 Sq. Ft.
1 Family Dwelling Asbestos Inspection W:/Word/HMG/13 Projects/13-2000-068.4629
4629 North 30th
Street July 10, 2013
Milwaukee, Wisconsin
Contract # 360-13-0745
5
Homogeneous Material Codes
SP1 Plaster
STX Texture
STX2 Texture #2
STX3 Texture #3
MCTMe Beige Ceramic Tile
MCTMt Tan Ceramic Tile
MCTMM Mortar
MFLw White Linoleum
MFLr Red Linoleum
MFLwy White & Gray Linoleum
MFLte Tan & Beige Linoleum
MFLc Cream linoleum
MDW Drywall/Joint Compound
MTP Transite
MPI Paper Insulation
MPT Tar Paper
MBI Blown in Insulation
MPG Glazing Compound
QA/QC Quality Assurance/Quality Control Sample
Note#1: Category I – Non-Friable Asbestos Containing Materials may become friable during mechanical
demolition activities or maybe considered friable prior to demolition activities due to its current
condition.
Note#2: If additional materials are discovered during demolition that are not listed above they are to be
assumed to be asbestos containing.
Note#3: A copy of this report should be transmitted to the demolition contractor.
Note#4: Estimated cost for friable asbestos …
V. EXCLUSIONS
No access to attic. Roof visible only from ground. No visible or accessible areas
were excluded from the scope of work.
HMG is not and shall not represent the building owner as its agent or representative for
the purpose of the US EPA/NESHAP and/or the WDNR/NR447 regulations, as
owner/operator.
This report represents the condition of the building and its visible/accessible suspect
asbestos containing materials at the date and the times of the onsite inspection. Hidden
materials or those materials that could be present at the point of inspection, over and
above those stated in the inspection report, are the responsibility of the building owner
and the demolition contractor.
VI. LIMITATIONS
The care and skill given to our procedures insures the most reliable test results possible.
HMG utilizes Quantem Laboratories for our Polarized Light Microscopy, unless
1 Family Dwelling Asbestos Inspection W:/Word/HMG/13 Projects/13-2000-068.4629
4629 North 30th
Street July 10, 2013
Milwaukee, Wisconsin
Contract # 360-13-0745
6
otherwise specified by the client. The findings and conclusions of HMG represent our
professional opinions extrapolated from limited data. Significant limited data is gathered
during the course of the preliminary asbestos specific site assessment. No other warranty
is expressed or implied. Prior to any abatement or renovation activities, it is
recommended that HMG be provided the opportunity to review such plans in order that
the inspection and assessments contained herein are properly interpreted and
implemented.
This report and the information contained herein are prepared for the sole and exclusive
use and possession of the City of Milwaukee Department of Neighborhood Services. No
other person or entity may rely on this report or any information contained herein. Any
dissemination of the Report or any information contained herein is strictly prohibited
without prior written authorization from Harenda Management Group.
1 Family Dwelling Asbestos Inspection W:/Word/HMG/13 Projects/13-2000-068.4629
4629 North 30th
Street July 10, 2013
Milwaukee, Wisconsin
Contract # 360-13-0745
7
VII. PRE-DEMOLITION ENVIRONMENTAL CHECKLIST
1 Family Dwelling Asbestos Inspection W:/Word/HMG/13 Projects/13-2000-068.4629
4629 North 30th
Street July 10, 2013
Milwaukee, Wisconsin
Contract # 360-13-0745
8
This guide lists materials and products commonly found in buildings with examples. It is
not intended as a substitute for reading the rules and statutes and making your own
independent determination of their applicability to your demolition project. These
examples presented here do not represent an exhaustive listing of types of materials that
may be required to be removed from the building prior to demolition.
ASBESTOS
Persons conducting inspections for asbestos must hold a valid asbestos inspector
certification card issued by the State of Wisconsin, Dept. of Health & Family Services.
Please follow the Asbestos Inspection and Sampling Protocol for Buildings to be
Demolished or Renovated.
CFCs and HALONS
Equipment that may contain CFCs and Halons:
N/A Air Conditioners (roof top, room, and central) Room
N/A Dehumidifiers
N/A Heat Pumps
N/A Refrigerators, Freezers, Chillers
N/A Vending Machines, Food Display Cases
N/A Walk-in Coolers
N/A Water Fountains (bubblers)
N/A Fire Extinguishers (both portable and installed HALON
suppression systems)
N/A Water Coolers
LEAD
Lead or Lead Based Paint (LBP) is common in many older buildings. When recycling
construction and demolition debris, be aware that wood containing lead paint may not be
chipped and spread for landscaping. State law also prohibits the sale or transfer of any
fixture or other object containing LBP that might be placed upon any surface of a
dwelling, which is ordinarily accessible to children.
1 Family Dwelling Asbestos Inspection W:/Word/HMG/13 Projects/13-2000-068.4629
4629 North 30th
Street July 10, 2013
Milwaukee, Wisconsin
Contract # 360-13-0745
9
MERCURY
Products that may contain mercury:
LIGHTING
N/A Fluorescent Lights
N/A High Intensity Discharge
-Metal Halide
-High Pressure Sodium
-Mercury Vapor
N/A Neon
N/A Switches for lighting using mercury relays
-Look for any control associated with exterior or automated
lighting systems such as "Silent" wall switches.
HVAC
Check thermostats and any control associated with air handling units for switches
containing mercury.
HEATING, VENTILATING AND AIR CONDITIONING SYSTEMS
N/A Old Thermostats
N/A Aquastats
N/A Firestats
N/A Manometers
N/A Thermometers
BOILERS, FURNACES, HEATERS AND TANKS
N/A Mercury Flame Sensors by pilot lights
N/A Manometers, Thermometers, Gauges
N/A Pressure-trol
N/A Float or Level Controls
N/A Space Heaters
1 Family Dwelling Asbestos Inspection W:/Word/HMG/13 Projects/13-2000-068.4629
4629 North 30th
Street July 10, 2013
Milwaukee, Wisconsin
Contract # 360-13-0745
10
ELECTRICAL SYSTEMS – 1 Breaker Box in Back Entry
N/A Load Meters and Supply Relays
N/A Phase Splitters
N/A Microwave Relays
N/A Mercury Displacement Relays
PCBs
For electrical devices manufactured prior to 1987, it is safe to assume that they contain
PCBs and should be managed accordingly. Most equipment manufactured after this time
will say "PCB Free". The following is a list of areas in a building were PCBs may be
found:
N/A Transformers
N/A Capacitors (appliances, electronic equipment)
N/A Heat Transfer Equipment
N/A Light Ballasts
N/A Specialty Paints (such as for swimming pools or other industrial
applications)
N/A Sumps or Oil Traps (in maintenance and industrial facilities)
OTHER ENVIRONMENTAL ISSUES
N/A Hazardous Waste
N/A Oil Tanks
N/A Well Abandonment
N/A Junk Auto Tires
N/A Junk Vehicles
* 4 Gallons Paint in Kitchen
1 Family Dwelling Asbestos Inspection W:/Word/HMG/13 Projects/13-2000-068.4629
4629 North 30th
Street July 10, 2013
Milwaukee, Wisconsin
Contract # 360-13-0745
11
VIII. LABORATORY RESULTS
2033 Heritage Park Drive I Oklahoma City, OK 73120 I (405) 755-72721 Fax (405) 755-2058
Polarized Light Microscopy Asbestos Analysis Report
QuanTEM Lab No. 223815 Client: Han!nda Management Group
Account Number: B929 Jolene Harenda P.O. Box 511305
Date Received: 07/05/2013 New Berlin, WI 53151-2105 Received By: Joanna Mueller
Date Analyzed: 07/08/2013 Project: DNS
Analyzed By: Sandy Baker Project Location: Milwaukee, WI
Methodology: EPA/600/R-93/116 Project Number: 13-2000-068.4629
QuanTEM Client Color I Non-Asbestos Non Fibrous Sample ID Sample ID Composition Description Asbestos(%) Fiber(%)
-----·-001 1-4629 Layered Beige Asbestos Not Present NA Clay
Ceramic Tile
OOla Layered Gray Asbestos Not Present NA Quartz
Grout Clay
002 2-4629 Homogeneous Light Gray Asbestos Not Present Glass Fiber 10 Vinyl
Sheet Vinyl Binder
003 3-4629 Homogeneous Tan/Brov.n Asbestos Not Present Cellulose 20 Vinyl
Sheet Vinyl Glass Fiber 5 Binder
'()04 4-4629 Homogeneous Light Gray Asbestos Not Present Cellulose 25 Vinyl
Sheet Vinyl Glass Fiber 5 Binder
005 5-4629 Homogeneous White Asbestos Not Present NA CaC03
Ceiling Texture Paint
006 6-4629 Hom.ogeneous White Asbestos Not Present ]';-A CaC03
Ceiling Texture Paint
Unless otherwise noted, upon receipt the condition of the sample was acceptable for analysis.
QuanTE1'.1 is aNVLAP accredited TEM and PLM laboratory {Lab Code: 101959-0). This report relates only to the specific items tested. NVLAP accreditation applies only to analysis performed utilizing EPA/600/M4-82-020 and EPA/600/R-93/116 methods. This report may not be used to claim product endorsement by NVLAP or any
other agency ofthe US Government. This report may not be reprodu~ed except in full, without the v.Titten approval of the laboratory.
Page 1 of 7
2033 Heritage Park Drive I Oklahoma City. OK 73120 I (405) 755-7272/ Fax (405) 755-2058
Polarized Light Microscopy Asbestos Analysis Report
QuanTEM Lab No. 223815 Client: Harenda Management Group
Account Number: B929 Jolene Harenda P.O. Box 511305
Date Received: 07/05/2013 New Berlin, WI 53151-2105 Received By: Joanna Mueller
Date Analyzed: 07/08/2013 Project: DNS
Analyzed By: Sandy Baker Project Location: Milwaukee, WI
Methodology: EPA/600/R-93/116 Project Number: 13-2000-068.4629
QJ.lanTEM Client Color/ Non-Asbestos ~on Fibrous SampleiD Sample ID ·Composition Description Asbestos (%) Fiber(%)
007 7-4629 Layered White Asbestos Not Present NA CaC03
Ceiling Texture Paint
007a Layered Tan Asbestos Not Present NA CaC03
Ceiling Texture Paint
008 8-4629 Homogeneous Peach Asbestos Not Present NA Vinyl
Sheet Vinyl
009 9-4629 Layered Beige Asbestos Not Present NA Clay
Ceramic Tile
009a Layered Gray Asbestos Not Present NA Quartz
Grout Clay
010 10-4629 Homogeneous Gray Asbestos Not Present NA Glue
Mastic
011 11 -4629 Homogeneous B~ige Asbestos Not Present Cellulose 25 Vinyl
Sheet Vinyl Glass Fiber 5 Binder
Unless otherwise noted, upon receipt the condition of the sample was acceptable for analysis.
QuanTEM is aNVLAP accredited TEM and PLM laboratory (Lab Code: 101959-0). This report relates only to the specific items tested. NVLAP accreditation applies only to analysis performed utilizing EPA/600/M4-&:i-020 and EPA/600/R-93!1 16 methods. This report may not be used to claim product endorsement byN'VLAP or any
other agency of the US Government. This report may not be reproduced except in full, without the "ritten approval of the laboratory.
Page 2 of 7
2033 Heritage Park Drive I Oklahoma City, OK 73120 I (405) 755-7272 1 Fax (405) 755-2058
Polarized Light Microscopy Asbestos Analysis Report
QuanTEM Lab No. 223815 Client: Harenda Management Group
Account Number: B929
Date Received: 07/05/2013
Received By: Joanna Mueller
Date Analyzed: 07/08/2013
i\nalyzed By: Sandy Baker
Methodology: EPN600/R-93/116
QuanTEM Client Sample ID Sample ID Composition
012 12-4629 Homogeneous
013 13-4629 Homogeneous
014 14-4629 Homogeneous
015 15-4629 Layered
015a Layered
016 16-4629 Layered
016a Layered
Project:
Project Location:
Project Number:
Color I Description
White
Texture
White .
Texture
White
Texture
White
Texture
White
Sheetrock
\X<'hite
Ceiling Texture
\Vhite
Joint Compound
Jolene Harenda P.O. Box 511305 New Berlin, WI 53151-2105
DNS
Milwaukee, WI
13-2000-068.4629
Non-Asbestos Asbestos(%) Fiber(%)
Asbestos Not Present NA
Asbestos Not Present NA
Asbestos Not Present NA
Asbestos Not Present NA
Asbestos Not Present KA
Asbestos Not Present NA
Asbestos Kat Present NA
Unless otherwise noted, upon receipt the condition of the sample was acceptable for analysis.
Non Fibrous
CaC03 Paint
CaC03 Paint
CaC03 Paint
CaC03 Paint
Gypsum
CaC03 Paint
CaC03
QuanTEM is a NVLAP accredited TEM and PLM laboratory (Lab Code: 101959-0). This report relates only to the specific items tested. NVL-\P accreditation applies only to analysis performed utilizing EP A/600/M4-82 -020 and EP A/600/R -93/ 116 methods . This report may not be used to claim product endorsement by NVLAP or any
other agency of the US Government. This report may not be reproduced except in full, without the written atfproval of the laboratory. '
Page 3 of 7
2033 Heritage Park Drive I Oklahoma City, OK 73120 I (405) 755-7272 1 Fax (405) 755-2058
Polarized Light Microscopy Asbestos Analysis Report
QuanTEM Lab No. 223815 Client: Harenda Management Group
AC{;ount Number: B929 Jolene Harenda P.O. Box 511305
Date Received: 07/05i2013 New Berlin, Wl53151-2105 Received By: Joanna Mueller
Date Analyzed: 07./08/2013 Project: DNS
Analyzed By: Sandy Baker Project Location: Milwaukee, WI
Methodology: EP A/600/R-93/116 ·Project Number: 13-2000-068.4629
QuanTEM Client Color I Non-Asbestos Non Fibrous Sample ID Sample ID Composition Description Asbestos(%) Fiber(%)
-·----016b Layered White Asbestos Not Present Cellulose 35 Gypsum
Sheetrock
017 17-4629 Layered White Asbestos Not Present NA CaC03
Texture
017a Layered Wbite Asbestos Not Present Cellulose 30 Gypsum
Sheetrock
018 ·18-4629 Layered White Asbestos Not Present NA CaC03
Texture Paint
018a Layered Light Gray Asbestos Not Present Talc . 10 Quartz
Skim Coat CaC03
018b Layered Gray Asbestos Present Animal Hair 3 Quartz
Plaster Chrysotile <1 Sand
019 19-4629 Layered White Asbestos Not Present NA Quartz
Skim Coat CaC03
Unless otherwise noted, upon receipt the condition of the sample was acceptable for analysis.
QuanTEM is a NVLAP accredited TEM and PLM laboratory (Lab Code: l 0 19 59-0). This report relates only to the specific items tested. NVLr'\P accreditation appiies only to analysis performed utilizing EP A/600/M4-82-020 and EP A/600/R-93/116 methods. This report may not be used to claim product endorsement by NVLAP or any
other agency of the US Government. This report may not be reproduced except in full, without the written approval of the laboratory ..
Page 4 of 7
2033 Heritage Park Drive I Oklahoma City, OK 73120 I (405) 755-7272/ Fax (405) 755-2058
Polarized Light Microscopy Asbestos Analysis Report
QuanTEM Lab No. 223815 Client: Harenda Management Group Account Number: B929 Jolene Harenda
P.O. Box 511305 Date Received: 07/05/2013 New Berlin, WI 53151-2105 Received By: Joanna Mueller
Date Analyzed: 07/08/2013 Project: DNS Analyzed By: Sandy Baker Project Location: Milwaukee, WI Methodology: EP A/600/R-93/116 Project Number: 13-2000-068.4629
QuanTEM Client Color I Non-Asbestos Non Fibro"us Sample ID Sample ID Composition Description Asbestos (%) Fiber(%)
019a Layered Gray Asbestos Present Cellulose <1 Quartz
Plaster Chrysotile <1 Animal Hair 2 Sand
020 20-4629 Layered Tan Asbestos Kot Present NA Quartz
Skim Coat CaC03
020a Layered Gray Asbestos Not Present Cellulose < 1 Quartz
Plaster Animal Hair 2 Sand
021 2 1-4629 Homogeneous White Asbestos Not Present. Cellulose 5 CaC03
Ceiling Texture Paint
022 22-4629 Homogeneous 'N"'hite Asbestos Not Present NA CaC03
Texture Paint
023 23-4629 Homogeneous White Asbestos Not Present NA CaC03
Texture Paint
024 24-4629 Homogeneous Gray Asbestos Present NA CaC03
Transite Chrysotile 30 Paint
Unless otherwise noted, upon receipt the condition of the sample was acceptable for analysis.
QuanTEM is a NVLAP accredited TEM and PLM laboratory (Lab Code: 10 1959-0). This report relates only to the specific itell!S tested. NVLAP accreditation applies only to analysis performed u tilizing EP A/600!M4-82-020 and EP A/600/R -93/116 methods . This report may not be used to claim product endorsement by NV LAP or any
other agency ofthe US Government. This re,Port may not be reproduced except in full , without the v.Titten approya[ of the laboratory.
Page 5 of 7
2033 Heritage Park Drive I Oklahoma City, OK 73120 I (405) 755-7272/ Fax (405) 755-2058
Polarized Light Microscopy Asbestos Analysis Report
QuanTEM Lab No. 223815 Client: Harenda Management Group Account Number: B929 Jolene Harenda
P.O. Box 511305 Date Received: 07/05/2013 New Berlin, WI 53151-2105 Received By: Joanna Mueller
Date Analyzed: 07/08/2013 Project: DNS
Analyzed By: Sandy Baker Project Location: Milwaukee, WI
Methodology: EPA/600/R-93/116 Project Number: 13-2000-068.4629
QuanTEM Client Color/ Non-Asbestos Non Fibrous Sample ID Sample ID Composition Description Asbestos(%) Fiber(%)
025 25-4629 Homogeneous Gray Asbestos Present NA CaC03
Transite Chrysotile 30 Paint
026 26-4629 Homogeneous Gray Asbestos Present NA CaC03
Transite Chrysotile 30 Paint
027 27-4629 Homogeneous Silver/Tan Asbestos Not Present Cellulose 90 Foil
Pipe Covering
028 28-4629 Homogeneous Silver/Tan Asbestos Not Present Cellulose 90 Foil
Pipe Covering
029 29-4629 Homogeneous Silver/Tan Asbestos Not Present Cellulose 90 Foil
Pipe Covering
030 30-4629 Layered Black Asbestos Not Present Cellulose 60 Tar
Tar Paper
030a Layered Black Asbestos Not Present NA Tar
Tar
Unless otherwise noted, upon receipt the condition of the sample was acceptable for analysis.
QuanTEM is a NVLAP accredited TEM and PLM laboratory (Lab Code: 101959-0). This report relates only to the specific items tested. NVLAP accreditation applies orJy to analysis performed utilizing EPA/600/lv14-82-020 and EPA/600/R-93/116 methods. This report may not be used to claim product endorsement by NVLAP or any
other agency of the L'S Government. This report may not be reproduced except in full, without the written approval of th~ laboratory.
Page 6 of7
jl.fl e LABORATORIES
2033 Her~age Park Drive I Oklahoma City, OK 73120 I (405) 755-7272 / Fax (405) 755-2ose
Polarized Light Microscopy Asbestos Analysis Report
QuanTEMLabNo. 223815
Account Number: B929
Date Received: 07/05/2013
Received By: Joanna Mueller
Date Analyzed: 07/08/2013
Analyzed By:
Methodology:
QuanTEM Sample ID
031
032
033
Sandy Baker
EPA/600/R-93/ 116
Client SampleiD
31-4629
32-4629
33-4629
Composition
Homogeneous
Homogeneous
Homogeneous
Client: Harenda Management Group Jolene Harenda P.O. Box 511305 New Berlin, WI 53151-2105
Project: DNS
Project Location: Milwaukee, WI
Project Number: 13-2000-068.4629
Color I Description
Tan
Window Glazing
Silver/Tan
. Pipe Covering
Brown
Sheet Vinyl
Asbestos(%)
Asbes1os Not Present
Asbestos Not Present
Asbes1os Not Present
7/8/2013 --- -
Date of Report
Non-Asbestos Fiber(%)
NA
Non Fibrous
CaC03 Paint
Cellulose 90 Paint
Cellulose 25 Vinyl
Glass Fiber 5 Binder
Unless otherwise noted, upon receipt the condition of the sample was acceptable for analysis.
QuanTEM is a WLAP accredited TEM and PLM laboratory (Lab Code: 101959-0). This report relates only to the specific items tested. ~VLAP accreditation appl ies o11\y to analysis performed utilizing EP N600fM4-82-020 and EP A/600/R-93/116 methods. This report may not be used to claim product endorsement by NVLAP or any
other agency of the US Govel1111?ent. This report may not be reproduced except in full, without the V.'l'itten approval of the laboratory.
Page 7 of 7
BORA TORIES www.QuanTEM.com
( -L(_bl>J
2 l d-~b29 -"'lb2-9 ---
4 I l.f~ '-{'5fl-9
5 15 -'-{(o~'} 6 ' f?~ L£b?~ 7 /-'-«d,Q 8 %~~~q 9 -:-i&;lq_
[!1-· .l : 10 [() -<./{dq I --
ASBESTOS CHAIN OF CUSTODY 2033 Heritage Park Drive, Okla~ma City, OK 73120-7502 (800) 822-1650 • (405) 755-72Y2 • Fax: (405) 755-2058
LEGAL DOCUMENT - PLEASE PRINT LEGIBLY
. Milwaukee, WI ------~ , - ----------
13-2000-068.4629
Air- NIOSH 7402 Bulk- Quantitative [weight%]- Chatfield
Dust- Presence I Absence
Drinking Water- EPA 100.2 Dust - Quantitative [tibers/ sq.cml- ASTM 05755
---'---~+....;;..;.."'----------'·"--·;- - - " ":' ' . -~· .•..• " ····~·. 'f"
I
f \Y
3 Page 1 of
SATURDAY SAMPLE DELIVERY- CALL TO SCHEDULE • Use this address for Saturday Delivery only: 4220 N. Santa Fe Ave., Oklahoma City, OK 731 OS-85 17 • Mark Package "Hold for Saturday Pickup"
~~~9 1--- ...,..
tL-<.((ol; -
1~ 14 /';-<{~q
15 I I C: • ({, _...,. I ffi
-16 -
17
I I
I
ASBESTOS CHAIN OF CUSTODY 2033 Heritage Park Drive, Okla~oma City, OK 73120-7502 (800) 822-1650 • (405) 755-7272 • Fax: (405)755-2058
LEGAL DOCUMENT - PLEASE PRINT LEGIBLY
. . :..
.. ,
Page 2 of 3
SATURDAY SAMPLE DELIVERY- CALL TO SCHEDULE • Use this address for Saturday Delivery only: 4220 N. Santa Fe Ave., Oklahoma City, OK 73105-8517 • Mark Package "Hold for Saturday Pickup"
34 I
35 I
36 I
37 i
38 I
39 I
40 I
41 :
42 I
43 I
44 I
45 I
:~ I 48
49 I
so I
... ulJvRATORI ES www.QuanTEM.com
I D D -
i D I D
D D D
I D I D
D D
I D D
•
D D
I D D
! ASBESTOS CHAIN OF CUSTODY 2033 Heritage Park Drive, Okla~oma City, OK 73120-7502 (800) 822-1650 • (405) 755-72,172 • Fax: (405) 755-2058
i
LEGAL DOCUMENT - P~EASE PRINT LEGIBLY '
·------- ·-·' !
Page 3 of 3
SATURDAY SAMPLE DELIVERY - CALL TO SC HE DU LE • Use this address for Saturday Delivery only: 4220 N. Santa Fe Ave., Oklahoma City, OK 731 05-8517 • Mark Package "Hold for Saturday Pickup"
2033 Heritage Park Drive I Oklahoma City, OK 73120 I (405) 755-7272/ Fax (405) 755-2058
Polarized Light Microscopy Asbestos Analysis Report
QuanTEM Lab No. 224053 Client: Harenda Management Group Jolene Harenda AccountNumber: B929
Date Received:
Received By:
Date Analyzed:
Analyzed By:
Methodology:
·QuanTEM Sample ID
001
002
07/11/2013
Sherrie Leftwich
07/11/2013
Sandy Baker
EPA/600/R-93/116
Client Sample ID Composition
P.O. Box 511305 New Berlin, WI 53151-2105
Project: PT CT for 223815, DNA
Project Location: Milwaukee, WI
Project Number: 13-2000-068.4629
Color I Description Asbestos(%)
Non-Asbestos Fiber(%)
.......... ········-·--------
18-4629
19-4629
Homogeneous
Homogeneous
Gray
Plaster
Gray
Plaster
Asbestos Not Present
400 Point Count
Asbestos Not Present
400 Point Count
7/1112013
Date of Report
Unless otherwise noted, upon receipt the condition of the sample was acceptable for analysis.
NA
NA
Non Fibrous
QuanTEM is a NVLAP accredited TEM and PLM laboratory (Lab Code: 101959-0). This report relates only to the specific items tested. NVLAP accreditation applies only to analysis performed utilizing EPN600/M4-82-020 and EPN600/R-93/116 methods. This report may not be used to claim product endorsement byNVLAP or any
other agency of the US Government. This report may not be reproduced e:::cept in full , without the written approval of the laboratory.
Page 1 of 1
LAIIOKATORIES www.QuanTEM.corn
ASBESTOS CHAIN OF CUSTODY 2033 Heritage Park Drive. Oklahoma City, OK 73120-7502 (800} 822-1650 • (4DS}7SS-7272 • Fax: (405) 755-2058
lEGAL DoCUMENT - PLEASE PRINT LEGIBLY
f~~~~!1~g]j[} U~fim£~~~Tq<I~F ''~i\~~r"'::jr · ··'''~'liif'll~~'P~~~on~~~~~
f ::~::Y ~=~:~~:~~:~~~-~ment~~~~p ---- - .. \ :::~=: -(~-1- ~~ - ~~3-480~--~ ~ :::~~~~: Milwaukee, WI
;--~~~:~~r-:~ --8929 I e---~~;~ja~o~~~~@harenda.~~ : ; Pro~~o: ---1·3~2ooo-os.S .4629 ~~~w····.·. ""1 __ ,.,""-"'' j··· --······--·--···· ···-·- -----------· ·····-·-·····--··· ........... T .. . - ---- --- -··· ~~ - -~~aW.:~~: j. Nam<!: 1 Date: ___ L~~-~~~~':
Page of _1_
Other email
I J ~ t ; - ----- ·---.. . .... . ~ --------,;- :===:_··t· ···-----·-
! Bulk- Quant itative {weight"~)- Chatfield ·------ --··--··-·····---·"-·--·
.. ·-·· ····-···' ·-·-· ·-·-·-- ····--····-·--·---·--··--···· ... ..... -------·4 \-""""'--+----------·-·-·---·--· Dust· Quantitative [fibers/sq.cm]- ASTM 05755
··--~---------·•o ·--- --·--H-
r~~J~:-~~~I~~f,~-U~''L'-1''"-"'-~0---· ~'-''--:.. ... ... , .... ,'!",, ...... _._,.,,"
18-~~~-? __ .. ... :. ....... _[21 2 19-4629 0 3 0 4 0 5 0
i .. ··-r-· t
.... l I - -..L---..--·-······
6 0
I I
7 0 8 D
l . i ·----- 1 -1-- .
-- f -· ·· -· - ... · ··-···· · 9 D
·-·----···- . ···-·-·· · - -··-·---
10 D ··- · - ···· •. .J ... J ... . i .
SATURDAY SAMPLE DELIVERY· CALL TO SCHEDULE • Use this address for Saturday Delivery only: 4nO N. Santa Fe Ave~ Oklahoma City, OK 73105-8517 • Mark PliCk.age wHQid for Saturday Pi<kup"
1 Family Dwelling Asbestos Inspection W:/Word/HMG/13 Projects/13-2000-068.4629
4629 North 30th
Street July 10, 2013
Milwaukee, Wisconsin
Contract # 360-13-0745
12
IX. HMG CERTIFICATION
Dean Jacobs
ASBESTOS INSPECTION REPORT Job Site:
Fire Damaged 2 Family Dwelling
2829-31 North 33rd Street Milwaukee, Wisconsin
For:
City of Milwaukee Department ofNeighborhood Services
Attn: Marge Piwaron 841 North Broadway 151 Floor
Milwaukee, Wisconsin 53202-3613
HMG Report No.: 12-0210.2829 Contract No.: 360-12-0553
Asbestos Insp ctor No. Ail - 14370
Prepared by:
HARENDAMANAGEMENTGROUP P. 0. Box 511305
New Berlin, Wisconsin 53151-2105
October 2012
P.O. Box 511305 · New Ber~ Wisconsin 53 151-2105 · (414) 383-4800 · (414) 383-4805
TABLE OF CONTENTS
I. Introduction ........................ ....... ....... ............ ...... ...... .... ......... .. ............... .................. 2
II. Building Survey .......... ........... ..... ......... ........ .............. ................. .... ......................... 2
III. The Laboratory ... .......... ....... .. ................................. ......................... .. ......... ..... ......... 2 A. Method of Analysis
IV. Findings and Observations ............. .... ........ ........ .. .......... .. .................... ......... ........... 3
V. Exclusions .... .. ............ ........ ... .................. ........... ... ......... ......... ....... .. ................. ... .... 6
VI. Limitations ....... .... ................ ............. .. .... ... ..... .. .. ............ ........ .......... .. ... ............. .... . 6
VII. Pre-Demolition Environmental Checklist .. . ... . ... .... . . .. . .. . ... .... ... ...... . .. . . . .. . . 7
VIII. Laboratory Results ... ..... ........... ..... ........... ...... .... .............. .......... ............ ..... ........... 11
IX. HMG Certifications .. ................... ... .. ............... .. .......... ....... ...... .... ......... .. .. ... .... .... . 12
2 Family Dwelling AsbeStos Inspection 2829·3 1 North 33"' Street Milwaukee, Wisconsin Contract# 360-12-0553
WJWord/HMG112 Projects/12· 0210.2829 October 12, 2012
HMG Project # 12·0210
I. INTRODUCTION
Harenda Management Group (HMG) was retained by the City of Milwaukee Department ofNeighborhood Services to conduct an inspection for possible asbestos containing materials in the dwelling at 2829-31 North 33rd Street, Milwaukee, Wisconsin.
The inspection included plaster, tar paper, drywaiVjoint compound, linoleum, blown in insulation, duct paper, flue packing, and window glazing compound to determine if asbestos containing materials were present within the space as required by US EPA NESHAP regulation 40 CFR 61 Subpart M
II. BUILDING SURVEY
Marge Piwaron, ofthe City of Milwaukee Department ofNeighborhood Services, authorized HMG to conduct a building survey and to analyze samples taken during the inspection.
On October 5, 2012, HMG conducted an asbestos inspection of a two family dwelling scheduled for mechanical demolition, located at 2829-31 North 33rd Street, Milwaukee, Wisconsin. The inspection was conducted by Dean Jacobsen, Wisconsin License No. All -14370.
The inspection was comprised of three elements:
1. A visual determination as to the extent of suspect materials within the building.
2. Sampling and documentation of observable suspect materials. Category I nonfriable materials were assumed to be asbestos containing and not sampled.
3. Quantification of observable positive materials existing within the spaces.
The results of the survey integrated with the Polarized Light Microscopy with Dispersion Staining (PLM/DS) analysis of bulk samples taken are outlined in this document. If you have any questions please contact HMG at (414) 383-4800.
III. THE LABORATORY
A. METHOD OF ANALYSIS
Analysis is performed by using the bulk samples for visual observation and slide preparation(s) for microscopical examination and identification. The slides are analyzed for asbestos ( chrysotile, amosite, crodcidolite, anthophyllite, and actinolite/ tremolite ), fibrous non asbestos constituents (mineral wool, paper, etc.), and nonfibrous constituents. Asbestos is identified by refractive indices (obtained by using dispersion staining),
2 Family Dwelling Asbestos Inspection 2829-3 1 North 33"' Street Milwaukee. Wisconsin Contract# 360-!2-0553
2 W:/Word/HMG/ 12 Projects/12-02 10.2829 October 12. 2012
HMG Project# 12-0210
morphology, color, pleochroism, birefringence, extinction characteristics, and signs of elongation. The same characteristics are used to identify the non asbestos constituents. The microscopist visually estimates relative amounts of each constituent using a stereoscope if necessary. The test results are based on a visual determination of relative volume of the bulk sample components. The results are valid only for the item tested. Current US EPA NESHAP regulations state asbestos materials means material containing more than 1% asbestos as determined using the method specified in Appendix E, Subpart E, 40 CFR Part 763 Section I, Polarized Light Microscopy. Refer to 29 CFR 1926.1101 (Construction) and 29 CFR 1910.1001 (General Industry) for specific OSHA requirements.
IV. FINDINGS AND OBSERVATIONS
The materials identified as suspect asbestos containing materials (ACM) include plaster, tar paper, drywall/joint compound, linoleum, blown in insulation, duct paper, flue packing, and window glazing compound. These materials were sampled and the following results were noted:
Sample# Location and Description
I-2829a I st floor - front stair- on landing - tan and brown linoleum
I-2829b I 51 floor - front stair - on landing- leveling compound
2-2829a 2nd floor - front stair - on landing - brown linoleum
2-2829b 2no floor - front stair- on landing - leveling compound
3-2829 Attic- east side under floor - blown in insulation 4-2829 Attic - center under floor - blown in insulation 5-2829 Attic - west side under floor - blown in insulation 6-2829 2nd floor - rear stair - on landing - orange and
brown linoleum 7-2829 151 floor - rear stair- on landing- brown and
gray linoleum 8-2829 151 floor- pantry - under floor tile - tan linoleum
9-2829 151 floor - kitchen - west side under floor tile - tar paper
10-2829 151 floor - kitchen - center under floor tile - tar paper
11-2829 2no floor - hall - under floor tile -tar paper 12-2829 1st floor- bathroom - under floor tile - beige and
orange linoleum l3-2829a 151 floor - dining room- north wall- plaster base
coat 13-2829b 1 ' 1 floor- dining room- north wall- plaster skim
coat 14-2829a 151 floor - living room - west wall - plaster base
coat
2 Family Dwelling Asbesros Inspection 2829·3 1 Nonh 33'" Streel
3 Milwaukee, W"1$C0nsin Conrract # 360-12.0553
Results
Positive 20% Chrysotile Negative
Positive 20% Chrysotile Negative
Negative Negative Negative
Positive 20% Chrysotile Negative
Positive 20% Chrysotile Negative
Negative
Negative Negative
Negative
Negative
Negative
Approximate Romogeneous Quantitv Code
15 Sq. Ft. MFLtn
N/A MFLtn
15 Sq. Ft. MFLn
N/A MFLn
N/A MBI N/A MBI N/A MBI
20 Sq. Ft. MFLon
N/A MFLny
24 Sq. Ft. MFLt
N/A MPT
NIA MPT
N/A MPT N/A MFLeo
N/A SPl
NIA SP1
N/A SPl
W:/Word/HMG/ 12 Projects/12.0210 .2829 October 12, 2012
HMG Project M 12.021 o
Sample# Location and Description
14-2829b }51 floor- living room -west wall - plaster skim
coat 15-2829 151 floor - kitchen - south wall - plaster base coat
15-2829b 1 '1 floor - kitchen - south wall- plaster skim coat 16-2829a l st floor - northeast bedroom - south wall -
plaster base coat 16-2829b I 51 floor- northeast bedroom - south wall -
plaster skim coat 17-2829a 2nd floor - northeast bedroom - east wall - plaster
base coat 17-2829b 2nd floor - northeast bedroom - east wall - plaster
skim coat 18-2829a 2nd floor - dining room- west wall- plaster base
coat 18-2829b 2nd floor - dining room - west wall - plaster skim
coat 19-2829a 2nd floor - southeast room - east wall - plaster
base coat 19-2829b 2na floor - southeast room - east wall - plaster
skim coat 20-2829 151 floor - living room - east window - glazing
compound 21-2829 Basement - west window - glazing compound 22-2829 Attic - east window - glazing compound
23-2829a 1st floor - dining room - ceiling - plaster #2 23-2829b l st floor - dining room - ceiling - texture 24-2829a 1st floor- kitchen - ceiling - plaster #2 24-2829b 1st floor - kitchen - ceiling - texture 25-2829a I st floor- kitchen - ceiling- plaster #2 25-2829b 1st floor - kitchen - ceiling - texture 26-2829 151 floor - kitchen - on south wall - cream
linoleum 27-2829 1 '1 floor- kitchen - on north wall - cream
linoleum 28-2829 I 51 floor - kitchen - on west wall - cream
linoleum 29-2829 Basement - on north side of chimney - top layer
- gray flue packing 30-2829 Basement - on north side of chimney - bottom
layer - white flue I>_acking 31-2829 Basement - on south side of chimney - light gray
flue Jlacking 32-2829 Basement- south wall- plaster #3 33-2829 Basement - west wall - plaster #3 34-2829 Basement - north wall - plaster #3 35-2829 Basement- on boot - duct paper
36-2829 Basement - on return - duct paper
37-2829 Basement- on duct on floor - duct paper
38-2829 2"a floor - bathroom - beige linoleum
2 Family Dwelling Asbestos Inspection 2829-3 I Nonh 33'" Street 4 MiiWllllkee, Wisconsin Cootraet # 360- 12-0SSJ
Results
Negative
Negative Negative Negative
Negative
Negative
Negative
Negative
Negative
Negative
Negative
Negative
Negative Negative Negative Negative Negative Negative Negative Negative Negative
Negative
Negative
Negative
Negative
Negative
Neg_ative Negative Negative
Positive 60% Chrysotile
Positive 60% Chrysotile
Positive 60% Chrysoti1e Negative
Approximate Homogeneous Quantity Code
N/A SPI
N/A SPI N/A SPI N/A SPl
NIA SPl
N/A SPI
NIA SPI
NIA SPI
NIA SPI
N/A SPI
NIA SPI
N/A MPG
NIA MPG NIA MPG NIA SP12 NIA SPI2 NIA SP12 N/A SP12 NIA SP12 NIA SP12 N/A MFLc
NIA MFLc
N/A MFLc
NIA TFPy
NIA TFPw
N/A TFPylight
N/A SPI3 NIA SPI3 NIA SPI3
20 Sq. Ft. TDW
Reference TDW 35-2829
Reference TDW 35-2829
N/A MFLe
W:/WordiHMG/ 12 Projects/12-02 10.2829 October 12.2012
HMG Project# 12-0210
Sample# Location and Description
39-2829 2nd floor- kitchen - west side under floor tile -gray and tan linoleum
40-2829 2nd floor- kitchen - east side under floor tile-gray and tan linoleum
41-2829 2nd floor - kitchen - north side under floor tile -gray and tan linoleum
42-2829 Quality Assurance/ Quality Control Sample of Sample 1-2829
37-2651 Quality Assurance/ Quality Control Sample of Sample 6-2829
Notes: N/A = Not Applicable Sq. Ft.= Square Feet
Results
Negative
Negative
Positive 20% Chrysotile
Positive 20% Chry_sotile
Positive 20% Chrysotile
Assumed Cate o I Non-Friable Asbestos Containin Floor Level
Roof
Floor Tile Mastic Carpet Mastic
Bedroom
Homogeneous Material Codes
MFLtn MFLn MBI MFLon MFLny MFLt MPT MFLeo SPl MPG SP1 #2 MFLc TFPy TFPw TFPy light SP1#3 TDW MFLe MFLyt QA/QC
Tan/Brown Linoleum Brown Linoleum Blown In Insulation Orange/Brown Linoleum Brown/Gray Linoleum Tan Linoleum Tar Paper Beige/Orange Linoleum Plaster Window Glazing Compound Plaster No. 2 Cream Linoleum Gray Flue Packing White Flue Packing Light Gray Flue Packing Plaster No. 3 Duct Wrap Beige Linoleum Gray/Tan Linoleum Quality Assurance/Quality Control Sample
Approximate Homogeneous Quantity Code
NIA MFLyt
NIA MFLyt
150 Sq. Ft. MFLyt
N/A QAQC
N/A QAQC
230 Sq. Ft.
Note# I: Category I - Non-Friable Asbestos Containing Materials may become friable during mechanical demolition activities or maybe considered friable prior to demolition activities due to its current condition.
Note#2: If additional materials are discovered during demolition that are not listed above they are to be assumed to be asbestos containing.
2 Family Dwelling Albestos Inspection 2829·31 North 33,. Streer Milwaukee, \V!SCOnsin Contra<! # 360-12.0553
5 W:/Word!HMG/12 Projec!SI12.0210.2829 October 12,2012
HMG Projec~ # 12.02 10
Note#3: A copy of this report should be transmitted to the demolition contractor.
Note#4: Additional duct paper may be discovered within walls and ceilings. Exploratory demolition required for exact quantity.
Note#S: Estimated cost for friable asbestos removal
V. EXCLUSIONS
Roof visible only from ground. No visible or accessible areas or material were excluded from this scope of work.
HMG is not and shall not represent the building owner as its agent or representative for the purpose of the US EPAINESHAP and/or the WDNR/NR447 regulations, as owner/operator.
This report represents the condition of the building and its visible/accessible suspect asbestos containing materials at the date and the times of the onsite inspection. Hidden materials or those materials that could be present at the point of inspection, over and above those stated in the inspection report, are the responsibility of the building owner and the demolition contractor.
VI. LIMITATIONS
The care and skill given to our procedures insures the most reliable test results possible. HMG utilizes Schneider Laboratories for our Polarized Light Microscopy, unless otherwise specified by the client. The findings and conclusions ofHMG represent our professional opinions extrapolated from limited data. Significant limited data is gathered during the course of the preliminary asbestos specific site assessment. No other warranty is expressed or implied. Prior to any abatement or renovation activities, it is recommended that HMG be provided the opportunity to review such plans in order that the inspection and assessments contained herein are properly interpreted and implemented.
This report and the information contained herein are prepared for the sole and exclusive use and possession of the City of Milwaukee Department of Neighborhood Services. No other person or entity may rely on this report or any information contained herein. Any dissemination of the Report or a71y information contained herein is strictly prohibited without prior written authorization from Harenda Management Group.
2 Family Dwelling Asbestos Inspectioo 2829·3 I North 33"' Street Milwaukee, \Vlseoosin Contract # 360-12-0553
6 W:/Word/HMG/12 Proje<t$112..0210.2829 October 12, 2012
HMG Project# 12·02 10
VII. PRE-DEMOLITION ENVIRONMENTAL CHECKLIST
2 Family Dwelling Asbestos Inspection 2829-3 1 Norlh 33,. Slreet Milwaukee. WlSCOnsin Contract # 360-12-CSSJ
7 W:/Word/HMG/12 Projects/12-C210.2829 October 12, 2012
1-D.iG Projectii12-C210
This guide lists materials and products commonly found in buildings with examples. It is not intended as a substitute for reading the rules and statutes and making your own independent determination of their applicability to your demolition project. These examples presented here do not represent an exhaustive listing of types of materials that may be required to be removed from the building prior to demolition.
ASBESTOS Persons conducting inspections for asbestos must hold a valid asbestos inspector certification card issued by the State of Wisconsin, Dept. of Health & Family Services. Please follow the Asbestos Inspection and Sampling Protocol for Buildings to be Demolished or Renovated.
CFCs and HALONS Equipment that may contain CFCs and Halons:
N/A Air Conditioners (rooftop, room, and central)
N/ A Dehumidifiers
N/ A Heat Pumps
N/ A Refrigerators, Freezers, Chillers
N/ A Vending Machines, Food Display Cases
N/A Walk-in Coolers
N/A Water Fountains (bubblers)
N/ A Fire Extinguishers (both portable and installed HALON suppression systems)
N/A Water Coolers
LEAD Lead or Lead Based Paint (LBP) is common in many older buildings. When recycling construction and demolition debris, be aware that wood containing lead paint may not be chipped and spread for landscaping. State law also prohibits the sale or transfer of any fixture or other object containing LBP that might be placed upon any surface of a dwelling, which is ordinarily accessible to children.
2 Family Dwelling Asbestos Inspection 2829-3 1 Nonh 33,. Stree1 Milwaukee, Wisconsin Contract# 360-12-0553
8 W:JWo rd/HMG/12 Projects/12-0210.2829 October 12, 2012
HMG Project# 12-0210
MERCURY Products that may contain mercury:
LIGHTING N/A
NIA
Fluorescent Lights
High Intensity Discharge -Metal Halide -High Pressure Sodium -Mercury Vapor
NIA Neon
Nl A Switches for lighting using mercury relays -Look for any control associated with exterior or automated lighting systems such as "Silent" wall switches.
HVAC Check thermostats and any control associated with air handling units for switches containing mercury.
HEATING, VENTILATING AND AIR CONDITIONING SYSTEMS
N/A Old Thermostats
N/ A Aquastats
N/ A Firestats
N/ A Manometers
N/ A Thermometers
BOILERS, FURNACES, HEATERS AND TANKS- 2 Furnaces & 2 Hot Water Heaters in the Basement
N/ A Mercury Flame Sensors by pilot lights
Nl A Manometers, Thermometers, Gauges
N/ A Pressure-trol
N/ A Float or Level Controls
N/ A Space Heaters
2 Family Dwelling Asbestos Inspection 2829-31 Nonh 33" Street Milwaukee, Wisconsin Contract 11360-12.0553
9 W:/Word/HMG/ 12 Projects/12-0210.2829 October 12, 2012
HMG Project# 12.0210
ELECTRICAL SYSTEMS- 2 Electric Breaker Boxes in the Basement
Nl A Load Meters and Supply Relays
NIA Phase Splitters
N/ A Microwave Relays
N/ A Mercury Displacement Relays
PCBs For electrical devices manufactured prior to 1987, it is safe to assume that they contain PCBs and should be managed accordingly. Most equipment manufactured after this time will say "PCB Free". The following is a list of areas in a building were PCBs may be found:
N/ A Transformers
N/A Capacitors (appliances, electronic equipment)
N/ A Heat Transfer Equipment
N/A Light Ballasts
N/ A Specialty Paints (such as for swimming pools or other industrial applications)
N/A Sumps or Oil Traps (in maintenance and industrial facilities)
OTHER ENVIRONMENTAL ISSUES
N/A Hazardous Waste
N/ A Oil Tanks
N/A Well Abandonment
N/ A Junk Auto Tires
N/ A Junk Vehicles
* 1 Water Meter in the Basement * 1 Gallon of Paint in the Attic * 1 Gallon ofUsed Oil in the Back Yard *One 5 Gallon Can of Paint in the 1st Floor Foyer
2 F amiJy Dwelling Asbestos insp<ction 2829· 31 Nonh 33,. Street Milwaukee, Wisconsin Contract# 36().12.0553
10 W:/Worci/HMG/12 Projects/12.0210.2829 October 12, 2012
HMGProject # 12·0210
2 Family Dwelli.og Asbestos Inspection 2829-31 Nonh 33" Street .Milwaukee, Wisconsin Contract # 360-12-0553
VIII. LABORATORY RESULTS
11 W:/Word/HMG/12 Projects/12-0210.2829 October 12, 2012
HMG Project# 12-0210
SCHNEIDER LABORATORIES GLOBAL INCORPORATED
2512 W. Cary Street· Richmond, Virginia • 23220-5117 804-353-6778 • 800-785-LABS (5227) • (FAX) 804-359-1475 Over 25 Years of Excellence in Service and Technology
AIHAIELLAP 100527, ISO/IEC 17025, NVLAP 101150-0, VELAP 460135, NYELAP/NELAC 11413
LABORATORY ANALYSIS REPORT Asbestos Identification by EPA Method1 600/R-93/116
ACCOUNT#: 4001-12-768
CLIENT: Harenda Management Group
ADDRESS: 1237 West Bruce Street
Milwaukee, WI 53204 PROJECT NAME: DNS
JOB LOCATION:
PROJECT NO.: 12-0210.2829 PONO.:
Client SLI Sample
Sample Sample/ Identification/
No. Layer 10 Layer Name
1-2829 31641414
Layer 1: Linoleum Beige, Org.Bound/Fibrous
Layer 2: Skim Coat White, Granular
2-2829 31641415
Layer 1: Flooring Beige, Org.Bound/Fibrous
Layer 2: Skim Coat White, Granular
3-2829 31641416
Layer 1: Insulation Beige, Fibrous
Layer 2: Skim Coat White, Granular
Total Number of Pages in Report: 7
Results relate only to samples as received by the laboratory.
Using SLI AG
DATE COLLECTED:
DATE RECEIVED: DATE ANALYZED:
DATE REPORTED:
Sample Type:
10/8/2012
10/8/2012 10/9/2012
BULK
PLM Analysis Results
Asbestos Fibers Other Materials
20% CHRYSOTILE 20% CELLULOSE FIBER
None Detected
20% CHRYSOTILE
None Detected
None Detected
None Detected
10% MINERAU GLASS WOOL
50% NON FIBROUS MATERIAL
100% NON FIBROUS MATERIAL
20% CELLULOSE FIBER
10% MINERAUGLASS WOOL
50% NON FIBROUS MATERIAL
100% NON FIBROUS MATERIAL
65% CELLULOSE FIBER
15% MINERAUGLASS WOOL
20% NON FIBROUS MATERIAL
100% NON FIBROUS MATERIAL
Visit www.slabinc.com for current certifications.
Samples analyzed by the EPA Test Method are subject to the limitations of light microscopy including matrix interference. Gravimetric reduction and correlative analyses are recommended for all non-friable, organically bound materials. This method has a reporting limit of 1% or greater. Visual estimation contains an inherent range of uncertainty. This report must not be reproduced except in full with the approval of the lab, and must not be used to claim NVLAP or other gov't agency endorsement.
Account- Workorder 4001-12-768 (Continued)
Client SLI Sample
Sample Sample/ Identification/
No. LayeriD Layer Name
4-2829 31641417
Layer 1: Insulation Beige, Fibrous
Layer 2: Skim Coat White, Granular
5-2829 31641418
Layer 1: Insulation Beige, Fibrous
6-2829 31641419
Layer 1: Flooring Beige, Org.Bound/Fibrous
7-2829 31641420
Layer 1: Flooring Black, Org.Bound/Fibrous
8-2829 31641421
Layer 1: Flooring Beige, Org.Bound/Fibrous
9-2829 31641422
Layer 1: Felt Black, Fibrous
10-2829 31641423
Layer 1: Felt Black, Fibrous
11-2829 31641424
Layer 1: Felt Black, Fibrous
Total Number of Pages in Report: 7
Results relate only to samples as received by the laboratory.
Page 2 (Continued)
PLM Analysis Results
Asbestos Fibers
None Detected
None Detected
None Detected
20% CHRYSOTILE
None Detected
20% CHRYSOTILE
None Detected
None Detected
None Detected
Other Materials
65% CELLULOSE FIBER
15% MINERAUGLASS WOOL
20% NON FIBROUS MATERIAL
100% NON FIBROUS MATERIAL
65% CELLULOSE FIBER
15% MINERAUGLASS WOOL
20% NON FIBROUS MATERIAL
20% CELLULOSE FIBER 10% MINERAUGLASS WOOL
50% NON FIBROUS MATERIAL
35% CELLULOSE FIBER
15% MINERAUGLASS WOOL
50% NON FIBROUS MATERIAL
20% CELLULOSE FIBER
10% MINERAUGLASS WOOL
50% NON FIBROUS MATERIAL
65% CELLULOSE FIBER
15% MINERAUGLASS WOOL
20% NON FIBROUS MATERIAL
65% CELLULOSE FIBER 15% MINERAUGLASS WOOL 20% NON FIBROUS MATERIAL
65% CELLULOSE FIBER
15% MINERAUGLASS WOOL 20% NON FIBROUS MATERIAL
Visit www.slabinc.com for current certifications.
Samples analyzed by the EPA Test Method are subject to the limitations of light microscopy including matrix interference. Gravimetric reduction and correlative analyses are recommended for all non-friable, organically bound materials. This method has a reporting limit of 1% or greater. Visual estimation contains an inherent range of uncertainty. This report must not be reproduced except in full with the approval of the lab, and must not be used to claim NVLAP or other gov't agency endorsement.
Account- Workorder 4001-12-768 (Continued) Page 3 (Continued)
Client SLI Sample
Sample Sample/ Identification/ PLM Analysis Results No. Layer ID Layer Name Asbestos Fibers Other Materials
12-2829 31641425
Layer 1: Flooring None Detected 35% CELLULOSE FIBER
Beige, OrgJ=!ound/Fibrous 15% MINERAUGLASS WOOL
50% NON FIBROUS MATERIAL
13-2829 31641426
Layer 1: Plaster None Detected 100% NON FIBROUS MATERIAL
Beige, Granular
Layer 2: Skim Coat None Detected 100% NON FIBROUS MATERIAL
White, Granular
14-2829 31641427
Layer 1: Plaster None Detected 100% NON FIBROUS MATERIAL
Beige, Granular
Layer 2: Skim Coat None Detected 100% NON FIBROUS MATERIAL
White, Granular
15-2829 31641428
Layer 1: Plaster None Detected 100% NON FIBROUS MATERIAL
Beige, Granular
Layer 2: Skim Coat None Detected 100% NON FIBROUS MATERIAL
White, Granular
16-2829 31641429
Layer 1: Plaster None Detected 100% NON FIBROUS MATERIAL
Beige, Granular
Layer 2: Skim Coat None Detected 100% NON FIBROUS MATERIAL
White, Granular
17-2829 31641430
Layer 1: Plaster None Detected 100% NON FIBROUS MATERIAL
Beige, Granular
Layer 2: Skim Coat None Detected 100% NON FIBROUS MATERIAL
White, Granular
Total Number of Pages in Report: 7
Results relate only to samples as received by the laboratory. Visit www.slabinc.com for current certifications.
Samples analyzed by the EPA Test Method are subject to the limitations of light microscopy including matrix interference. Gravimetric reduction and correlative analyses are recommended for all non-friable, organically bound materials. This method has a reporting limit of 1% or greater. Visual estimation contains an inherent range of uncertainty. This report must not be reproduced except in full with the approval of the lab, and must not be used to claim NVLAP or other gov't agency endorsement.
Account- Workorder 4001-12-768 (Continued) Page 4 (Continued)
Client SLI Sample
Sample Sample/ Identification/ PLM Analysis Results No. LayeriD Layer Name Asbestos Fibers Other Materials
18-2829 31641431
Layer 1: Plaster None Detected 100% NON FIBROUS MATERIAL
Gray, Granular
Layer 2: Textured Material None Detected 100% NON FIBROUS MATERIAL
Beige, Granular
19-2829 31641432
Layer 1: Plaster None Detected 100% NON FIBROUS MATERIAL
Gray, Granular
Layer 2: Textured Material None Detected 100% NON FIBROUS MATERIAL
Beige, Granular
20-2829 31641433
Layer 1: Granular Material None Detected 100% NON FIBROUS MATERIAL
Beige, Granular
21-2829 31641434
Layer 1: Granular Material None Detected 100% NON FIBROUS MATERIAL
Beige, Granular
22-2829 31641435
Layer 1: Granular Material None Detected 100% NON FIBROUS MATERIAL
Green, Granular
23-2829 31641436
Layer 1: Plaster None Detected 100% NON FIBROUS MATERIAL
Beige, Granular
Layer 2: Textured Material None Detected 100% NON FIBROUS MATERIAL
Beige, Granular
24-2829 31641437
Layer 1: Plaster None Detected 100% NON FIBROUS MATERIAL
Beige, Granular
Total Number of Pages in Report: 7
Results relate only to samples as received by the laboratory. Visit www.slabinc.com for current certifications.
Samples analyzed by the EPA Test Method are subject to the limitations of light microscopy including matrix interference. Gravimetric reduction and correlative analyses are recommended for all non-friable, organically bound materials. This method has a reporting limit of 1% or greater. Visual estimation contains an inherent range of uncertainty. This report must not be reproduced except in full with the approval of the lab, and must not be used to claim NVLAP or other gov't agency endorsement.
Account - Workorder 4001-12-768 (Continued) Page 5 (Continued)
Client SLI Sample
Sample Sample/ Identification/ PLM Analysis Results No. LayeriD Layer Name Asbestos Fibers Other Materials
Layer 2: Textured Material None Detected 100% NON FIBROUS MATERIAL
Beige, Granutar
25-2829 31641438
Layer 1: Plaster None Detected 100% NON FIBROUS MATERIAL
Beige, Granular
Layer 2: Textured Material None Detected 100% NON FIBROUS MATERIAL
Beige, Granular
26-2829 31641439
Layer 1: Flooring None Detected 35% CELLULOSE FIBER
Beige/Black, Org.Bound/Fibrous 15% MINERAUGLASS WOOL
50% NON FIBROUS MATERIAL
27-2829 31641440
Layer 1: Flooring None Detected 35% CELLULOSE FIBER
Beige/Black, Org.Bound/Fibrous 15% MINERAUGLASS WOOL
50% NON FIBROUS MATERIAL
28-2829 31641441
Layer 1: Flooring None Detected 35% CELLULOSE FIBER
Beige/Black, Org.Bound/Fibrous 15% MINERAUGLASS WOOL
50% NON FIBROUS MATERIAL
29-2829 31641442
Layer 1: Granular Material None Detected 100% NON FIBROUS MATERIAL
Gray, Granular
30-2829 31641443
Layer 1: Granular Material None Detected 100% NON FIBROUS MATERIAL
Gray, Granular
31-2829 31641444
Layer 1: Granular Material None Detected 100% NON FIBROUS MATERIAL
Gray, Granular
32-2829 31641445
Layer 1: Granular Material None Detected 2% CELLULOSE FIBER
Gray, Granular 98% NON FIBROUS MATERIAL
Total Number of Pages In Report: 7
Results relate only to samples as received by the laboratory. Visit www.slabinc.com for current certifications.
Samples analyzed by the EPA Test Method are subject to the limitations of light microscopy including matrix interference. Gravimetric reduction and correlative analyses are recommended for all non-friable, organically bound materials. This method has a reporting limit of 1% or greater. Visual estimation contains an inherent range of uncertainty. This report must not be reproduced except in full with the approval of the lab, and must not be used to claim NVLAP or other gov't agency endorsement.
Account- Workorder 4001-12-768 (Continued)
Client SLI Sample
Sample Sample/ Identification/
No. Layer 10 Layer Name
33-2829 31641446
Layer 1: Granular Material Gray, Granular
34-2829 31641447
Layer 1: Granular Material Gray, Granular
35-2829 31641448
Layer 1: Insulation Beige, Fibrous
36-2829 31641449
Layer 1: Insulation Beige, Fibrous
37-2829 31641450
Layer 1: Insulation Beige, Fibrous
38-2829 31641451
Layer 1: Flooring Gray, Org.Bound/Fibrous
39-2829 31641452
Layer 1: Flooring Gray, Org.Bound/Fibrous
40-2829 31641453
Layer 1: Flooring Gray, Org.Bound/Fibrous
41-2829 31641454
Layer 1: Flooring Beige, Org.Bound/Fibrous
Total Number of Pages in Report: 7
Results relate only to samples as received by the laboratory.
Page 6 (Continued)
PLM Analysis Results
Asbestos Fibers
None Detected
None Detected
60% CHRYSOTILE
60% CHRYSOTILE
60% CHRYSOTILE
None Detected
None Detected
None Detected
20% CHRYSOTILE
Other Materials
2% CELLULOSE FIBER
98% NON FIBROUS MATERIAL
2% CELLULOSE FIBER
98% NON FIBROUS MATERIAL
20% CELLULOSE FIBER
10% MINERAUGLASS WOOL
10% NON FIBROUS MATERIAL
20% CELLULOSE FIBER
10% MINERAUGLASS WOOL
10% NON FIBROUS MATERIAL
20% CELLULOSE FIBER
10% MINERAUGLASS WOOL
10% NON FIBROUS MATERIAL
35% CELLULOSE FIBER
15% MINERAUGLASS WOOL
50% NON FIBROUS MATERIAL
35% CELLULOSE FIBER
15% MINERAUGLASS WOOL
50% NON FIBROUS MATERIAL
35% CELLULOSE FIBER
15% MINERAUGLASS WOOL
50% NON FIBROUS MATERIAL
20% CELLULOSE FIBER
10% MINERAUGLASS WOOL
50% NON FIBROUS MATERIAL
Visit www.slabinc.com for current certifications.
Samples analyzed by the EPA Test Method are subject to the limitations of light microscopy including matrix interference. Gravimetric reduction and correlative analyses are recommended for all non-friable, organically bound materials. This method has a reporting limit of 1% or greater. Visual estimation contains an inherent range of uncertainty. This report must not be reproduced except in full with the approval of the lab, and must not be used to claim NVLAP or other gov't agency endorsement.
Account- Workorder 4001-12-768 (Continued)
Client SLI Sample
Sample Sample/ Identification/
No. Layer ID Layer Name
42-2829 31641455
Layer 1: Flooring Beige, Org.Bound/Fibrous
43-2829 31641456
Layer 1: Flooring Beige, Org.Bound/Fibrous
Analyst: MOHAMMED B. HASHIM
Total Number of Pages in Report: 7
Results relate only to samples as received by the laboratory.
Page 7 (Continued)
PLM Analysis Results
Asbestos Fibers
20% CHRYSOTILE
20% CHRYSOTILE
Other Materials
20% CELLULOSE FIBER
10% MINERAUGLASS WOOL
50% NON FIBROUS MATERIAL
20% CELLULOSE FIBER
10% MINERAUGLASS WOOL
50% NON FIBROUS MATERIAL
Reviewed By: Hind Eldanaf, Microscopy Supervisor
Visit www.slabinc.com for current certifications.
Samples analyzed by the EPA Test Method are subject to the limitations of light microscopy including matrix interference. Gravimetric reduction and correlative analyses are recommended for all non-friable, organically bound materials. This method has a reporting limit of 1% or greater. Visual estimation contains an inherent range of uncertainty. This report must not be reproduced except in full with the approval of the lab, and must not be used to claim NVLAP or other gov't agency endorsement.
I
I I \
p.o. Box 511305
~ew Bertin WI 53151
Proleet Name: bNS
Prolect Location:
SCHNEIDER LABORATORIES, INC. 2512 West Cary Street, Richmond, Virginia 23220-5117
804-353-.ena • 800-785-LABS (5227) • Fax 804-359-1475
www.slabinc.com e-mail: [email protected]
4001
WOLabsl:
Phone I# FD.If
& E-rn.all
414-383-4800
414-383-4805 [email protected]
Soeciallnstructions [include reauests for special reportina or dttta oacka_ll_SS]
bO NOT ANALYZE MASTICS ProiKt Number: 12-0210.2829
0Weekend•
• not available for all tests 0Palnt
TYPE OF RESPIRATOR
Po Number: St.lto Of Collection Wt 'I )t~. ~~~,~~·~:d··;,rh~(.':'.;·: x// .;,..·;~~~I&;_~~,:~~ {sJt~~ 'b~~~·.t ,:·. / '·. ·~,:·!.<;;~\ ':~·:<·;~\':·~;·~·.:-:):_f."';· ·:.:r~~tJi A~~~;i:iS'et~ iii ~ihiA~~tJ(:::;·{~:·.::;,.';, ; ·;::;:, ·,:·;:n'::::::~. ··i'.
D 2 hours• All samples on form should be of SAMe J',J.-~~~t~ :ri;;:f~i'~i do~~-r \ :: :~~~ e~'l.k't~~hld:;;·~::·.· ~'</:~·~~~:i~(;.~~:b'~t~;::\'U,:'!: matrix typg Use additional forms as needed.
0 Same day• 0PCM (NIOSH 7400) IB.J PLM (EPA 600, 1982) 0 Leacl
\
1
0 1 business day• D Air 0 Solid 0TEM (AHERA) 0 PLM (EPA Point Count) 0 RCRA Metals
0 2 business-day• 0 Aqueous 0 Waste. 0TEM (EPA Levell!) 0 PLM (Qualitative only) OL-L--------1 IEJ3 business days• IBl Bulk 0 Wastewa.ter lD 0 NYELA? 198.11.41.6 1-"D..._,.,~.....,..~.,......,.,,....,.,..,...,.__,,---~
0 .5 business days• 0 Hi-Vol Filter (PM10) O Water, Drinking )/:::~~~ir~n~~~ ~~~-_:;;:;_;: 0 C~LAP (EP~ Interim) \. ~\\.j·'.i: ~b;)~~~a:,•;':,·, './.;:\ .. ~ O Full TCLP (10d) 0 Hi-Vol Filter (TSP) O Compliance OTotal Oust (NIOSH 0500) O TEM (Chatfield) 0 TCLP I Lead
Don 0 \Mpe OResp. Oust (NIOSH 0000) ... ln~--------!OTCLP I RCRA Metals
QSUica- FTIR (NIOSH 7602) FOR ASBESTOS AIR: inTCLP I Full (wl omanicsl
-:;y:,.,;\'.~:::~··; ' .(~~~~;:·~;{tif: ·::.'·; 0 ~pe.Co~stte
I Schedulerosholflanks,mulfl. 0Siudge 0----- osmca-XRD(NIOSH7500) . . '!!!f!Jis _&_~r;!~il}__ Os-• ·- · . n I .-. 0
· ·~- ~==~~~·~~~====~~~======~~=· ===== .. ====~'~w======~====~~us~E~D~: ==~==~~7=~~~~~~~===; Date Time Sample ldentificatlon Wiped . Type 1 Timr .. · !'low Rate3 •• .. . • -: TotaJ4 ·
Sample# Samoled SamQ.Ied (e.a. Emolovee SSN Blc!fL Materian Area Cft"l A B.P _J;; Start Stop Start Stop Air Vol
~~~~,-~~~~~-+----~---+--------------~---+--~--~--+---,_--~--~ I 'i~ ztz_9 ;5-2829
1~282.9
I 1{V'"~
11Type: A=ar&a B"blank P"l)8rsonal E=excursfon 2Beglnnfng/End of Sample Perfocl 3Pump Calibration in Liters/Minute
l$ampled by ~elinqulshed to lab by
~ME ~AME I ~~GNATURE ---------p~&nME _____________ __
~IGNATURE
PATE/TIME
10 Samole return reouested D Ambient tem...Q D Ice
~en l/1 10/5/12 11·00 /r-:_.... A
oc oH Cl nR IllS OX. [,c'1L'\. ( latlon
4volume In Liters [time in min • flow in Umfnl
1'--" / ... __ _
i i I
I l l
(jL; •. SCHNEIDER LABORATORIES, INC. WOL.abel:
2512 West Cary Street, Richmond, Virginia 23220-5117
-~- 804-353-6778 • 800-785-LABS (5227) • Fax 8Q4-.359-1475 . . . . ..
www.slabinc.com e-mail: [email protected] ..
Submitting _l Lab
Co. aronda Mllnaaement Group_ Usa-WO#
P.O. Box 511305 ACct# Phone#
Fax# 414-383-4800
& 414-383-4805 ti•w Bertin. WI 631_$1 4001 E-mail [email protected]
ProJect Name: bNS Special /nstructlons !include reczuestt; for SJJ_ec/al reoortina or dBta packages
f>ro:lect Location: PO NOT ANALYZE MASTICS
Pr9ject Number. 112-0210.2829
i>o Number: Stolte Of Collection ~I ::~xGu;~r~~~~d'Ti~'t• •• • :f': ·Ma'i.fi /~ol~' ~~t~~i~-oN'ei'h,; \};·· '· ~) .· .·-· .. ·, '• -1 _:~x ·' ·' ·. '· .. : . ·' ' ' .... '·. ' :•. · .. , . . " .; .>.yi::'.'/(i';·,:.>;, ••. ;;\~:1> ;i. '·. •;- .: .. '.::Teat. /.Aru.ivw:a ts&IOct'ALL'thafA~i)lvi., • · :. :, -.--,:.;'..
02hours• All samples on form should be of SAME · ~t~~ ~i-i ~iii~~,~~~::·. >· .~A.i~.-~-~'ui-~/k~-(o.'>··,_ '•_',<1 '':M~~f&::t~~~\ci~~~: ._,:•\'>· matzjx tvoe. Use acWtl/onal fonns as needed.
0 PCM (NIOSH 7400) 0 Same day" IBJ PLM (EPA 600, 1982) 0Lead
0 1 business day• OAir 0Sor!d 0TEM (AHERA) 0 PLM (EPA Point Count} 0 RCRA Metals
0 2 business day• 0Aqueous owasle 0TEM (EPA Level II) 0 PLM (Qualitative only} n IEJ3 business days• [8) Bulk 0 Wastewater In 0 NYELAP 198.1/.4/.6 ID 0 5 business days• 0 Hi-Vol Filter (PM1 O) O Water, Drinking .i;/·:. -~!Sri~lra~~~Ta~~--~/::··; 0 CAELAP (EPA Interim) ;-··;.-/\··.· M~t;·i~~~~i;·,;/(:+:i'.: Q Futl TCLP (10d) 0 Hi-Vot Filter (TSP) O Compliance OTotal Dust (NIOSH 0500} 0 TEM (Chatfleld) OTCLP / Leacl
0Weekend* oo~ 0 'Mpe QResp. Dust (NlOSH 0600) In QTCLP I RCRA Metals
• not available for all tests QPaint 0 IMpe, Composite QSRica • FTIR (NIOSH 7602} FOR ASBESTOS AIR: [n TCLP I Fufl Cw/ o_manic&j
Sc"*<<u/e rush 01J1at!IC3, multi- 0 Siudge 0 0 SVica • XRD (NIOSH 7500} TYPE OF RESPIRATOR .-:= .. t~::_-'.:·:!··.N:\~-·~ }:: ~~·;i:~~~;{~---:~~>·;·i·~:::/~: metals &. we.kend tulllln
IDsol _Q_ :o lr1 advtmee. USED:
Date Time ·· - sample Identification · \Niped. ' 'Type1 . · ·Time2 Flow Rate3 ·rotaf4·· Sample# Sampled Sarnpled ~_,g. Em_Q!~ee SSN Bldtl. Material) Area~ ABP,E Start Stop Start Stop Air Vol
\3-25~9
I~''Z.&l-9
I (S-~/ I
\ ((p -'2.'SZ:/
n-~
~ '8 -'"2&:2."
(Cf -75$;2.9
-k>-7.82.1 i le ( .-1..&2."? I ~-232.9
~3 _c.gC)
f2~-uz.q I
\ 1Type: A=area Bzblank P=pareonal E=excursion 2aeglnnlng/End of Sample Period JPump Calibration In WtereiMlnute "volume in Liters (tlmo in min • flow in Lim In]
~mpledby ~eltnqulshed to lab by •. ...£:tTiX 0 UPS
~~ME ~a~acobsen 0 USM ~AME OHO
\~ ODB jsiGNATURE !siGNATURE
10~2 17:00 V" ~uJ!TMlnsTL6sc£2 I
pATE!TlME pATEITIME .. --.::;:?__,~ ' / __ l
ID Sample return [eg__uested 0 Ambient temp 0 Ice oc pH Cl .ll_R Clt\5 OX I '\...._ \ ~ -
·((i~· SCHNEIDER LABORATORIES, WOL.abel:
INC. 2512 West Cary Street, Richmond, Virginia 23220-5117
804-353-6778 • 800-785-LABS (5227) • Fax 804-359-1475 : -:-.
www.slabinc.com e-mail: [email protected] Submitting _LI Lab
Co. arenda Manaal!mant Groug ua ... WO#
,..O.IIox 511305 AC:Clll Phone1ll
Fax# 414-383-4800
& 414-383-4805 Nllw Berlin WJJ 31151 4001 E-m all [email protected]:om
Proli!Ct Name: bNS Special Instructions !Include reouests for soecial reoortina or data packages]
ProJect Loc:at!on: DO NOT ANALYZE MASTICS
ProJect Number. ~2-0210.2829
PO Number: State Of CollecUon ~I .:f,\ ~~;.{X:b~~ ii~~ :: ·: : \/.<: ·rJi~~i ·~~~~~· -r,;·~.is~i~'il~Ei('<;.:.:.: ·. -:. <'· .: :; ", \ .. . ; ~· .. ~ -::'/ .. ~· .. \···:;.·:< r~~''/i~~~· ts~~ Al.~ ·~~t ·A~i~}?/;·.=~: ;:.;, ,J,• :·1.::./~\!;;:··;./} \:'.;. ·' :~ 02hours• ' ':·.''.· .. ·; :.:::. : ,: : . ·; .• .-· .. ~· : ~. ;·.: . .. : := :::.
;;.~~~ ·~·&;;~~ ·a~f~/i~~ i&;' /· ·::.·;.,;:;:. ~~~~~f~titt:ci~'r:~: !.·-·);';-. All samples on form should b& of SAME . AsbestoS' Ai'r'l Fiber. counts-". metriiC tyoo Use additions/ forms ss needed.
0Sameday• 0PCM (NIOSH 7400) IBJ PLM (EPA 600, 1982) 0Lead 0 1 business day• OAir 0Solld 0TEM (AHERA) 0 PLM (EPA Point Count) 0 RCRA Metals 0 2 business day• QAquaous 0Waste QTEM (EPA Level II) 0 PLM (Qualitative only) 0 [29 3 business days• IBJBulk 0 Wastewater n 0 NYELAP 198.1/.4/.6 lo 0 5 buslnS&s days• 0 HI-Vol F~ter(PM10) 0 Water, Drinking ·. '·\·~~~~~·ii~ r~~;' >A 0 CAELAP (EPA interim) l\·(;~,'; ~i"ta~~~ci}::::>•); Q Full TCLP (10d) 0 Hl-Vol Filer (TSP) 0 Compfiance QTotal Dust (NiOSH 0500) 0 TEM {Chatfield) QTCLP/Lead 0Weekend• QOil 0 'Mpe 0Resp. Dust (NIOSH 0600) lrJ 0 TCLP I RCRA Metals • not avaMable for all tests QPaint 0 Wipe, Composite QSUica • FTIR (NiOSH 7602) FOR ASBESTOS AIR: lnTCLP I Full lwf organics)
Sc/H:dua TUSh oiJlan/a, multi- QSiudge 0 QSDk:a - XRD (NIOSH 7500) TYPE OF RESPIRATOR G:_\<<<>'''::~~~:>::;iy>.;;,:: ~·· mew• & weeJcfltld re.ttstn ID son D ID ID adv;mco. USED: -.. . ·- .. .
Date· Tinie .. .
- ·· Sample IdentificatiOn" - ·· Wipad ·-r-ype1 ... - Ttri1'e2 . ..... - · •· ·.· · Flow Rate3 ~ - . "lotal4.
Samole# Samoled Samoled (e.a. Employee SSN Bldg, Material) Area(ft"} ABPE Start Sto_p Start Stoo Air Vol
\ ;?5~~
l~b-~ \ ~n~~ !
~'8-U2<}
23 .-ZJ'.Z::,
3o~23'2.'1 ' I
P(r-~1 I
I IP~ .. :z.gl.?
I
133-'2329 I
'f:!f'~ I
3;5-Lm 1"~~'282.9
1Type: A=area B=blank P=pensonal E=excunslon 2eeglnningfEnd of Sample Period 3Pump Calibration In Llte1111Minuto "vorume In Litera (time in min • flow In Umln]
s~mpled by 13 FX -Relinquished to lab by OUPS I
NAME Dean Jacobsen 0USM NAME OHD l P.GNATURE~ . c!fi.b¥-~IGNATURE
P~TE!TIME ~ATetTIME 17'00 l!aJ~ conl,Q~~T.J...3ndcondi5ons-2. I \
lrl• Samo!e return reouested Cl Ambient temo Ice oc oH Cl DRI:n:GOX \_ ~ ~
! ;
i-
SCHNEIDER LABORATORIES, INC. 2512 West Cary Street, Richmond, Virginia 23220-5117
804-353-6778 • 800-785-I..ABS {5227) • Fax 804-359-1475
www.slabinc.com
Ll . . Submitting Co. aronda Manaaement GrouD
e-mail: [email protected] l..aD
Use· WO#
IP.o. ao .. a113o5 'ACCtll'
k-.rew Berlin. WI 53181 4001
WOLabel:
Phone# l'axll
414-383-4800
414-383-4805 [email protected]
F>ro·ect Name: DNS Special Instructions [Include requests for special reporting or data oackB.C/es
Pro feet Location: DO NOT ANALYZE MASTICS
Proiect Number: ~ 2-021 0.2829
Po Number: stat& Of Collection ~I :~;t:'} fu~ i~~~~ ).;~~·:, ;·~ :\:''::,.'' ~Jiiisa.ri~ii ~~~-·~s~!ectb~~, ,; ;•:: ~: ··i ·-j/ '··: : ·:>,;· ·;:_·, ;~. ;~:.. , \ ;fribil,\~~~~-ts&~~·A((' ttiilt.:A~,~;;;;~;{>~ ',,::, -~~:;;: :~;\::. :\:)-;:;:\: ';;;\ 0 2 hours• All samples on form should be of SAME . A~6i~ci~· Alr·iF~'b~/rio~rifii •, ;?,;'::i~~~t);. But~ 1 A~b ioi~· ' 1• :\\.' . ·~g~~~T~~i'tc\nclSi•·<-<:
mafriK type Use additional forms as ne&ded. 0 Same day• 0PCM (NIOSH 7400) [g) PLM (EPA 600, 1982) 0 l ead
0 1 business day•
0 2 business day•
IEJ3 business days•
0 5 business days•
0 Full TCLP (1 Od)
oweekend•
0Air 0Solid
0 Aqueous 0 Waste
IEJ Bulk 0 Wastewater
0 Hi-Vol FITter (PM10) 0Watet,Drinking
0 Ht-Vol F~lln (TSP) O Compliance
QOii O VIJipe
QTEM (AHERA) 0 PLM (EPA Point Count) D RCRA Metals
QTEM (EPA l.evelll) 0 PLM (Qualitative only) LO....._ _____ _
In o NYeLAP 198.1/.4/.a ~-~.lo...L.~,..,.,~~~,_.,..,...,.,...,.,..,..,.~ 1·\:i M~~~;j~~u~ii~~':o>\·. 0 CAELAP (EPA Interim} >~'./ :~,~~~:~tr::y;_;_~: :·'; QTotal Dust (NIOSH 0500} O TEM (Chatfield) OTCLP I Lead
QResp. Dust (NIOSH 0600) 1"'10""'---------i QTCLP I RCRA Metals
• not available for all tests 0 Paint
s~~le rush 0111an~. mufti. 0 Sludge metal$ & weekend teats in O
0 Wl(Je, Composite QSUica - FTIR {NIOSH 7602)
0 ------ QSHica- XRD {NIOSH 7500)
FOR ASBESTOS AIR:
TYPE OF RESPIRATOR
lnTCLP I Full (WI ornanics)
. ,j~·.:··:x~:,'&h~'-rit-.::·'~?;::~). :c: .:_ 0 a<tv•nce. S01l D ID USED:
· - lime'! Row Rate3 - · · • · Torar··-
1 Samole# Date
Samoled -Time
Samoled · ··- Sample Identification · (e.a. Emolovee SSN Blda Material)
Wiped - ·Type1
Area (ft2) A B P,E Start Stop start Sloe Air Vol
I ~.-7l>29
I 'i:Z-288 \~----~--~~---+----------------4---~---r---+---+----r----+--~ . t.e-21)2.9
\ 1Typ&: A "llre& B=blank P=parsonal E=axcurslon 2Beglnnlng/End of Sam pia Period 3Pump Calibration In Liters/Minute "volume In Liters (time In min • flow in l./min]
ampled by ~elinquished to lab by
AME NAME Oea~Jaoobsen
~~GNATURE SIGNATURE a.,~ p~TErTIME pATEITIME 1~/12 11:0n 6 , 6-:---:--,.--~==:L-.::~~~~ I~ __.::::... ' 1m Samole return reauestedn Ambient temo D Ice oc p_H Cl R f::JS OX t~ _.;::-L
.... / -
2 Family Dwelling Asbestos Inspection 2829-31 North 33" Street Milwaukee, \Visconsin Contract# 360-12-0553
IX. HMG CERTIFICATION
12 W:/Word/HMG/12 Projects/12-0210.2829 October 12,2012
HMG Ptojtct # 12-0210
~·I
ASBESTOS INSPECTOR ·
STATE OF WISCONSlN
~ of1:kahh Semces
&an 'T·Jaoobsen
W i3<1s9'¥8l ·,tplin~ ·Dr .M.nske,ge 'Wf~3 fS0--.3401
Tfllin.mg due~y: IMHJ!Ol2
1237 West Bruce Street · Milwaukee, Wisconsin 53204 · (414) 383-4800 · (414) 383-4805
ASBESTOS INSPECTION REPORT
Job Site:
Fire Damaged
One Family Dwelling
3319 North 38th
Street
Milwaukee, Wisconsin
For:
City of Milwaukee
Department of Neighborhood Services
Attn: Marge Piwaron
841 North Broadway 1st Floor
Milwaukee, Wisconsin 53202-3613
HMG Report No.: 13-2000-068.3319
Contract No.: 360-13-0745
________________________ Dean Jacobsen
Asbestos Inspector No. AII – 14370
Prepared by:
HARENDA MANAGEMENT GROUP
1237 West Bruce Street
Milwaukee, Wisconsin 53204
October 2013
1 Family Dwelling Asbestos Inspection W:/Word/HMG/13 Projects/13-2000-068.3319
3319 North 38th Street October 15, 2013
Milwaukee, Wisconsin
Contract # 360-13-0745
1
TABLE OF CONTENTS
I. Introduction ..............................................................................................................2
II. Building Survey .......................................................................................................2
III. The Laboratory .........................................................................................................2
A. Method of Analysis
IV. Findings and Observations .......................................................................................3
V. Exclusions ................................................................................................................4
VI. Limitations ...............................................................................................................4
VII. Pre-Demolition Environmental Checklist…………………………………………6
VIII. Laboratory Results .................................................................................................10
IX. HMG Certifications ...............................................................................................11
1 Family Dwelling Asbestos Inspection W:/Word/HMG/13 Projects/13-2000-068.3319
3319 North 38th Street October 15, 2013
Milwaukee, Wisconsin
Contract # 360-13-0745
2
I. INTRODUCTION
Harenda Management Group (HMG) was retained by the City of Milwaukee Department of
Neighborhood Services to conduct an inspection for possible asbestos containing materials in the
dwelling at 3319 North 38th Street, Milwaukee, Wisconsin.
The inspection included plaster, blown in insulation, window glazing compound, duct paper,
drywall/joint compound, and flue packing to determine if asbestos containing materials were
present within the space as required by US EPA NESHAP regulation 40 CFR 61 Subpart M.
II. BUILDING SURVEY
Marge Piwaron, of the City of Milwaukee Department of Neighborhood Services, authorized
HMG to conduct a building survey and to analyze samples taken during the inspection.
On October 8, 2013, HMG conducted an asbestos inspection of a one family dwelling,
scheduled for mechanical demolition, located at 3319 North 38th Street, Milwaukee,
Wisconsin. The inspection was conducted by Demicca Coe, Wisconsin License No. AII –
156385.
The inspection was comprised of three elements:
1. A visual determination as to the extent of suspect materials within the building.
2. Sampling and documentation of observable suspect materials. Category I non-friable
materials were assumed to be asbestos containing and not sampled.
3. Quantification of observable positive materials existing within the spaces.
The results of the survey integrated with the Polarized Light Microscopy with Dispersion
Staining (PLM/DS) analysis of bulk samples taken are outlined in this document. If you have
any questions please contact HMG at (414) 383-4800.
III. THE LABORATORY
A. METHOD OF ANALYSIS
Analysis is performed by using the bulk samples for visual observation and slide preparation(s)
for microscopical examination and identification. The slides are analyzed for asbestos
(chrysotile, amosite, crodcidolite, anthophyllite, and actinolite/ tremolite), fibrous non asbestos
constituents (mineral wool, paper, etc.), and nonfibrous constituents. Asbestos is identified by
refractive indices (obtained by using dispersion staining), morphology, color, pleochroism,
birefringence, extinction characteristics, and signs of elongation. The same characteristics are
used to identify the non asbestos constituents.
The microscopist visually estimates relative amounts of each constituent using a stereoscope if
necessary. The test results are based on a visual determination of relative volume of the bulk
sample components. The results are valid only for the item tested. Current US EPA NESHAP
1 Family Dwelling Asbestos Inspection W:/Word/HMG/13 Projects/13-2000-068.3319
3319 North 38th Street October 15, 2013
Milwaukee, Wisconsin
Contract # 360-13-0745
3
regulations state asbestos materials means material containing more than 1% asbestos as
determined using the method specified in Appendix E, Subpart E, 40 CFR Part 763 Section I,
Polarized Light Microscopy. Refer to 29 CFR 1926.1101 (Construction) and 29 CFR 1910.1001
(General Industry) for specific OSHA requirements.
IV. FINDINGS AND OBSERVATIONS
The materials identified as suspect asbestos containing materials (ACM) include plaster, blown
in insulation, window glazing compound, duct paper, drywall/joint compound, and flue packing.
These materials were sampled and the following results were noted:
Sample # Location and Description Results Approximate
Quantity
Homogeneous
Code
1-3319 1st floor – living room – south wall – plaster Negative N/A SPl
2-3319a 1st floor – west bedroom – north wall – plaster
skim coat
Negative N/A SPl
2-3319b 1st floor – west bedroom – north wall – plaster
base coat
Negative N/A SPl
3-3319a 1st floor – north bedroom – west wall – plaster
skim coat
Negative N/A SPl
3-3319b 1st floor – north bedroom – west wall – plaster
base coat
Negative N/A SPl
4-3319 1st floor – kitchen – east wall – plaster Negative N/A SPl
5-3319a 1st floor – kitchen – ceiling – plaster skim coat Negative N/A SPl
5-3319b 1st floor – kitchen – ceiling – plaster base coat Negative N/A SPl
6-3319 1st floor – living room – on floor – blown in
insulation
Negative N/A MBI
7-3319 1st floor – west bedroom – on floor – blown in
insulation
Negative N/A MBI
8-3319 Attic – on floor – blown in insulation Negative N/A MBI
9-3319 1st floor – dining room – south window – glazing
compound
Negative N/A MPG
10-3319 1st floor – bathroom – north window – glazing
compound
Negative N/A MPG
11-3319 1st floor – rear hall – west window – glazing
compound
Negative N/A MPG
12-3319 1st floor – dining room – on vent – duct paper Positive 45%
Chrysotile
12 Sq. Ft. TDW
13-3319 1st floor – bathroom – on vent – duct paper Positive 45%
Chrysotile
Reference
12-3319
TDW
14-3319 Basement – on duct above sink – duct paper Positive 45%
Chrysotile
Reference
12-3319
TDW
15-3319a 1st floor – rear hall – ceiling – joint compound Negative N/A MDW
15-3319b 1st floor – rear hall – ceiling – drywall Negative N/A MDW
16-3319a Attic – south wall – joint compound Negative N/A MDW
16-3319b Attic – south wall – drywall Negative N/A MDW
17-3319a Attic – ceiling – joint compound Negative N/A MDW
17-3319b Attic – ceiling – drywall Negative N/A MDW
18-3319a Basement – top layer on chimney – gray flue
packing
Negative N/A TFPy
18-3319a Basement – bottom layer on chimney – tan flue
packing
Positive 3%
Chrysotile
1 Sq. Ft. TFPt
1 Family Dwelling Asbestos Inspection W:/Word/HMG/13 Projects/13-2000-068.3319
3319 North 38th Street October 15, 2013
Milwaukee, Wisconsin
Contract # 360-13-0745
4
Notes: N/A = Not Applicable
Sq. Ft. = Square Feet
Assumed Category I Non-Friable Asbestos Containing Material:
Floor Level Location Description Approximate Quantity
Roof Dwelling Asphalt Shingles & Flashing 700 Sq. Ft.
1st Kitchen/Hall Floor Tile & Mastics 150 Sq. Ft.
Homogeneous Material Codes
SPl Plaster
MBI Blown in Insulation
MPG Glazing Compound
MDW Drywall
TDW Duct Paper
TFPy Gray Flue Packing
TFPt Tan Flue Packing
Note#1: Category I – Non-Friable Asbestos Containing Materials may become friable during mechanical
demolition activities or maybe considered friable prior to demolition activities due to its current
condition.
Note#2: If additional materials are discovered during demolition that are not listed above they are to be
assumed to be asbestos containing.
Note#3: A copy of this report should be transmitted to the demolition contractor.
Note#4: Additional duct paper may be within walls and ceilings. Exploratory demolition required for exact
quantity.
Note#5: Estimated cost for friable asbestos removal …
V. EXCLUSIONS
Roof visible only from ground. No visible or accessible areas were excluded from the scope
of work.
HMG is not and shall not represent the building owner as its agent or representative for the
purpose of the US EPA/NESHAP and/or the WDNR/NR447 regulations, as owner/operator.
This report represents the condition of the building and its visible/accessible suspect asbestos
containing materials at the date and the times of the onsite inspection. Hidden materials or those
materials that could be present at the point of inspection, over and above those stated in the
inspection report, are the responsibility of the building owner and the demolition contractor.
VI. LIMITATIONS
The care and skill given to our procedures insures the most reliable test results possible. HMG
utilizes Quantem Laboratories for our Polarized Light Microscopy, unless otherwise specified by
the client. The findings and conclusions of HMG represent our professional opinions
extrapolated from limited data. Significant limited data is gathered during the course of the
preliminary asbestos specific site assessment. No other warranty is expressed or implied. Prior
1 Family Dwelling Asbestos Inspection W:/Word/HMG/13 Projects/13-2000-068.3319
3319 North 38th Street October 15, 2013
Milwaukee, Wisconsin
Contract # 360-13-0745
5
to any abatement or renovation activities, it is recommended that HMG be provided the
opportunity to review such plans in order that the inspection and assessments contained herein
are properly interpreted and implemented.
This report and the information contained herein are prepared for the sole and exclusive use and
possession of the City of Milwaukee Department of Neighborhood Services. No other person or
entity may rely on this report or any information contained herein. Any dissemination of the
Report or any information contained herein is strictly prohibited without prior written
authorization from Harenda Management Group.
1 Family Dwelling Asbestos Inspection W:/Word/HMG/13 Projects/13-2000-068.3319
3319 North 38th Street October 15, 2013
Milwaukee, Wisconsin
Contract # 360-13-0745
6
VII. PRE-DEMOLITION ENVIRONMENTAL CHECKLIST
1 Family Dwelling Asbestos Inspection W:/Word/HMG/13 Projects/13-2000-068.3319
3319 North 38th Street October 15, 2013
Milwaukee, Wisconsin
Contract # 360-13-0745
7
This guide lists materials and products commonly found in buildings with examples. It is
not intended as a substitute for reading the rules and statutes and making your own
independent determination of their applicability to your demolition project. These
examples presented here do not represent an exhaustive listing of types of materials that
may be required to be removed from the building prior to demolition.
ASBESTOS
Persons conducting inspections for asbestos must hold a valid asbestos inspector
certification card issued by the State of Wisconsin, Dept. of Health & Family Services.
Please follow the Asbestos Inspection and Sampling Protocol for Buildings to be
Demolished or Renovated.
CFCs and HALONS
Equipment that may contain CFCs and Halons:
N/A Air Conditioners (roof top, room, and central)
N/A Dehumidifiers
N/A Heat Pumps
N/A Refrigerators, Freezers, Chillers
N/A Vending Machines, Food Display Cases
N/A Walk-in Coolers
N/A Water Fountains (bubblers)
N/A Fire Extinguishers (both portable and installed HALON
suppression systems)
N/A Water Coolers
LEAD
Lead or Lead Based Paint (LBP) is common in many older buildings. When recycling
construction and demolition debris, be aware that wood containing lead paint may not be
chipped and spread for landscaping. State law also prohibits the sale or transfer of any
fixture or other object containing LBP that might be placed upon any surface of a
dwelling, which is ordinarily accessible to children.
1 Family Dwelling Asbestos Inspection W:/Word/HMG/13 Projects/13-2000-068.3319
3319 North 38th Street October 15, 2013
Milwaukee, Wisconsin
Contract # 360-13-0745
8
MERCURY
Products that may contain mercury:
LIGHTING
4 Fluorescent Lights – Living Room
N/A High Intensity Discharge
-Metal Halide
-High Pressure Sodium
-Mercury Vapor
N/A Neon
N/A Switches for lighting using mercury relays
-Look for any control associated with exterior or automated
lighting systems such as "Silent" wall switches.
HVAC
Check thermostats and any control associated with air handling units for switches
containing mercury.
HEATING, VENTILATING AND AIR CONDITIONING SYSTEMS
N/A Old Thermostats
N/A Aquastats
N/A Firestats
N/A Manometers
N/A Thermometers
BOILERS, FURNACES, HEATERS AND TANKS
N/A Mercury Flame Sensors by pilot lights
N/A Manometers, Thermometers, Gauges
N/A Pressure-trol
N/A Float or Level Controls
N/A Space Heaters
1 Family Dwelling Asbestos Inspection W:/Word/HMG/13 Projects/13-2000-068.3319
3319 North 38th Street October 15, 2013
Milwaukee, Wisconsin
Contract # 360-13-0745
9
ELECTRICAL SYSTEMS – 1 Electric Meter on Exterior. 1 Breaker Box in
Basement
N/A Load Meters and Supply Relays
N/A Phase Splitters
N/A Microwave Relays
N/A Mercury Displacement Relays
PCBs
For electrical devices manufactured prior to 1987, it is safe to assume that they contain
PCBs and should be managed accordingly. Most equipment manufactured after this time
will say "PCB Free". The following is a list of areas in a building were PCBs may be
found:
N/A Transformers
N/A Capacitors (appliances, electronic equipment)
N/A Heat Transfer Equipment
N/A Light Ballasts
N/A Specialty Paints (such as for swimming pools or other industrial
applications)
N/A Sumps or Oil Traps (in maintenance and industrial facilities)
OTHER ENVIRONMENTAL ISSUES
N/A Hazardous Waste
N/A Oil Tanks
N/A Well Abandonment
N/A Junk Auto Tires
N/A Junk Vehicles
* 1 Gas Meter on Exterior
1 Family Dwelling Asbestos Inspection W:/Word/HMG/13 Projects/13-2000-068.3319
3319 North 38th Street October 15, 2013
Milwaukee, Wisconsin
Contract # 360-13-0745
10
VIII. LABORATORY RESULTS
2033 Heritage Park Drtve I Oklahoma City, OK 73120 I (405) 755-7272 / Fax (405) 755-2058
Polarized Light Microscopy Asbestos Analysis Report
QuanTEM Lab No. 227958 Client: Harenda Management Group
Account Number: B929
Date Received: 10/10/2013
Received By: Joanna Mueller
Date Analyzed: 10/15/2013
Analyzed By: Crista] Veech
Methodology: EPA/600/R-93/ 116
QuanTEM Client Sample ID SamplelD Composition
001 1-3319 Homogeneous
002 2-33 19 Layered
002a Layered
003 3-3319 Layered
003a Layered
004 4-3319 Homogeneous
Project:
Project Location:
Project Number:
Color I Description
Gray
Plaster
Tan
Skim Coat
Gray
Plaster
Tan
Skim Coat
Tan
Plaster
Gray
Plaster
Jolene Harenda 1237 West Bruce St. Milwaukee, WI 53204
DNS
Milwaukee, WI
13-2000-068.33 19
Non-Asbestos Asbestos (%) Fiber{%)
Asbestos Not Present Wollastonite
Asbestos Not Present NA
Asbestos Not Present NA
Asbestos Not Present NA
Asbestos Not Present Cellulose
Asbestos Not Present Cellulose
Unless otherwise noted, upon receipt the condition ofthe sample was acceptable for analysis.
<I
<I
2
Non Fibrous
Gypsum Perlite
Gypsum Perlite Sand
Gypsum Perlite Sand
Gypsum Perlite Sand
Gypsum Perlite Sand
Gypsum Perlite Sand
QuanTEM is a NVLAP accredited PLM laboratory (Lab Code: 101959-0). This report relates only to the specific items tested. NVLAP accreditation applies only to analysis performed utilizing EPN600/M4-82-020 and EPN6001R-93/1 16 methods. This report may not be used to claim product endorsement by NVLAP or any agency
of the US Government. This report may not be reproduced except in full, without the written approval of the laboratory.
Page 1 of4
2033 Heritage Park Drive I Oklahoma City, OK 73120 I (405) 755-7272 / Fax (405) 755-2058
Polarized Light Microscopy Asbestos Analysis Report
QuanTEM Lab No. 227958 Client: Harenda Management Group
Account Number: B929
Date Received: 10/10/2013
Received By: Joanna Mueller
Date Analyzed: 10/15/2013
Analyzed By: Crista! Veech
Methodology: EPA/600/R-93/ 116
QuanTEM Client SamplelD SampleiD Composition
005 5-3319 Layered
005a Layered
006 6-3319 Homogeneous
007 7-3319 Homogeneous
008 8-3319 Homogeneous
009 9-3319 Homogeneous
Project:
Project Location:
Project Number:
Color I Description
Tan
Skim Coat
Tan
Plaster
Gray
Insulation
Gray
Insulation
Gray
Insulation
Tan
Window Glazing
Jolene Harenda 1237 West Bruce St. Milwaukee, WI 53204
DNS Milwaukee, WI
13-2000-068.33 19
Non-Asbestos Asbestos(%) Fiber(%)
Asbestos Not Present NA
Asbestos Not Present Cellulose 2 Wollastonite <t
Asbestos Not Present Cellulose 100
Asbestos Not Present Cellulose 100
Asbestos Not Present Cellulose 100
Asbestos Not Present NA
Non Fibrous
Gypsum Perlite Sand
Gypsum Perlite Sand
CaC03 Talc
010 10-3319 Homogeneous Tan
Window Glazing
Asbestos Not Present Cellulose <1 CaC03
Unless otherwise noted, upon receipt the condition of the sample was acceptable for analysis.
QuanTEM is a NVLAP accredited PLM laboratory (Lab Code: 101959-0). This report relates only to the specific items tested. NV LAP accreditation applies only to analysis performed utilizing EPN600/M4-82-020 and EPN600/R-93/116 methods. This report may not be used to claim product endorsement by NV LAP or any agency
of the US Government. This report may not be reproduced except in full, without the written approval of the laboratory.
Page 2 of4
2033 Heritage Park Drive I Oklahoma City, OK 73120 I (405) 755-7272/ Fax (405) 755·2058
Polarized Light Microscopy Asbestos Analysis Report
QuanTEM Lab No. 227958 Client: Harenda Management Group Jolene Harenda Account Number: B929
Date Received:
Received By:
Date Analyzed:
Analyzed By:
Methodology:
QuanTEM Sample ID
Oil
012
013
014
015
015a
10/ 10/2013
Joanna Mueller
10/ 15/2013
Crista) Veech
EPA/600/R-93/ 116
Client Sample ID
11-3319
12-33 19
13-3319
14-3319
15-3319
Composition
Homogeneous
Homogeneous
Homogeneous
Homogeneous
Layered
Layered
1237 West Bruce St. Milwaukee, WI 53204
Project: DNS
Project Location: Milwaukee, WI
Project Number: 13-2000-068.33 19
Color I Description
Tan
Window Glazing
Gray
Insulation
Gray
Insulation
Gray
Insulation
White
Joint Compound
White
Sheetrock
Asbestos(%)
Asbestos Not Present
Asbestos Present
Chrysotile
Asbestos Present
Chrysotile
Asbestos Present
Chrysotile
Asbestos Not Present
Asbestos Not Present
45
45
45
Non-Asbestos Fiber (%)
NA
Cellulose
Cellulose
Cellulose
NA
Cellulose
Unless otherwise noted, upon receipt the condition of the sample was acceptable for analysis.
50
50
50
10
Non Fibrous
CaC03
Binder
Binder
Binder
Gypsum Perlite Paint
Gypsum
QuanTEM is a NV LAP accredited PLM laboratory (Lab Code: 101959-0). This report relates only to the specific items tested. NVLAP accreditation applies only to analysis performed utilizing EPN600/M4-82-020 and EPN600/R-93/116 methods. This report may not be used to claim product endorsement by NVLAP or any agency
ofthe US Government. This report may not be reproduced except in full, without the written approval of the laboratory.
Page 3 of4
®
2033 Heritage Park Drive I Oklahoma City, OK 73120 I (405) 755-7272/ Fax (405) 755-2058
Polarized Light Microscopy Asbestos Analysis Report
QuanTEM Lab No. 227958 Client: Harenda Management Group Jolene Harenda Account Number: B929
Date Received:
Received By:
Date Analyzed:
Analyzed By:
Methodology:
QuanTEM Sample ID
016
016a
017
017a
018
018a
10/ 10/2013
Joanna Mueller
10/ 15/2013
Crista! V eech
EPA/600/R-93/116
Client Sample ID
16-3319
17-3319
18-3319
Composition
Layered
Layered
Layered
Layered
Layered
Layered
1237 West Bruce St. Milwaukee, WI 53204
Project: DNS
Project Location: Milwaukee, WI
Project Number: 13 • 2000-06 8.3 319
Color / Description
White
Joint Compound
White
Sheetrock
White
Joint Compound
White
Sheetrock
Gray
Coating
Tan
Stucco
Asbestos(%)
Asbestos Not Present
Asbestos Not Present
Asbestos Not Present
Asbestos Not Present
Asbestos Not Present
Asbestos Present
Chrysotile
I 0/15/2013 - - -Date of Report
3
Non-Asbestos Fiber(%)
Non Fibrous
- - - - ·- - ----NA CaC03
Perlite Paint
Cellulose 10 Gypsum
NA Gypsum Perlite Paint
Cellulose 10 Gypsum
Wollastonite 45 Gypsum Paint
NA Quartz CaC03
Unless otherwise noted, upon receipt the condition of the sample was acceptable for analysis.
QuanTEM is a NV LAP accredited PLM laboratory (Lab Code: 1 01959-0). This report relates only to the specific items tested. NVLAP accreditation applies only to analysis performed utilizing EPA/600/M4-82-020 and EPA/600/R-93/116 methods. This report may not be used to claim product endorsement byNVLAP or any agency
of the US Government. This report may not be reproduced except in full, without the written approval of the laboratory.
Page 4 of 4
ASBESTOS CHAIN OF CUSTODY 2033 Heritage Park Drive, Oklahoma City, OK 73120-7502 (800) 822-1650 • (405) 755-7272 • Fax: (405) 755-2058
LEGAL DOCUMENT - PLEASE PRINT LEGIBLY
Contact 1nformation 1 ProjectlnfO:trri'i'ti'Ob·':
company: Harenda Management Group Phone: (414) 383-4800 ' ProJectName: DNS - ----If-- ·· - - ---
Contact: Dean Jacobsen Celt Phone: Projectlocation: Milwaukee, WI
Account II: £-mail: [email protected] II ProjectiO' 13-2000-068.3319
Bulk- Quantitative (weight%]- Chatfield
Oust- Quantitative (fibers/sq.cm]- ASTM 05755
Page of~
QuanTEM Website · --
Other email
~ ~B ~--.~ SATU RDAV SAMPLE DELIVERY- CALL TO SCHEDULE • Use this address for Saturday Delivery only: 4220 N. Santa Fe Ave., Oklahoma City, OK 73105-8517 • Mark Package "Hold for Saturday Pickup"
LADUKATORIES www.QuanTEM.com
ASBESTOS CHAIN OF CUSTODY 2033 Heritage Park Drive, Oklahoma City, OK 73120-7502 (800) 822-1650 • (405) 755-7272 • Fax: (405) 755-2058
LEGAL DoCUMENT- PLEASE PRINT LEGIBLY
Page 2 of _;;;;z
0~-~ ~~\3-3Y) I 0 I
---· .. . . 3 22 - . 0 _ .--· _
~: 11· ' . 1-, 2
[ 3o · ~ I
SATURDAY SAMPLE DELIVERY - CALL TO SCHEDULE • Use this address for Saturday Delivery only: 4220 N. Santa Fe Ave., Oklahoma City, OK 73105-8517 • Mark Package "Hold for Saturday Pickup"
1 Family Dwelling Asbestos Inspection W:/Word/HMG/13 Projects/13-2000-068.3319
3319 North 38th Street October 15, 2013
Milwaukee, Wisconsin
Contract # 360-13-0745
11
IX. HMG CERTIFICATION
1237 West Bruce Street · Milwaukee, Wisconsin 53204 · (414) 383-4800 · (414) 383-4805
ASBESTOS SNIP INSPECTION REPORT
Job Site:
Fire Damaged
Two Family Dwelling
2529-31 North 39th
Street
Milwaukee, Wisconsin
For:
City of Milwaukee
Department of Neighborhood Services
Attn: Marge Piwaron
841 North Broadway 1st Floor
Milwaukee, Wisconsin 53202-3613
HMG Report No.: 13-2000-399.2529
Contract No.: 360-13-0745
________________________ Dean Jacobsen
Asbestos Inspector No. AII – 14370
Prepared by:
HARENDA MANAGEMENT GROUP
1237 West Bruce Street
Milwaukee, Wisconsin 53204
December 2013
2 Family Dwelling SNIP Asbestos Inspection W:/Word/HMG/13 Projects/13-2000-399.2529
2529-31 North 39th
Street December 20, 2013
Milwaukee, Wisconsin
Contract # 360-13-0745
1
TABLE OF CONTENTS
I. Introduction ..............................................................................................................2
II. Building Survey .......................................................................................................2
III. The Laboratory .........................................................................................................2
A. Method of Analysis
IV. Findings and Observations .......................................................................................3
V. Exclusions ................................................................................................................5
VI. Limitations ...............................................................................................................5
VII. Pre-Demolition Environmental Checklist…………………………………………7
VIII. Laboratory Results .................................................................................................11
IX. HMG Certifications ...............................................................................................12
2 Family Dwelling SNIP Asbestos Inspection W:/Word/HMG/13 Projects/13-2000-399.2529
2529-31 North 39th
Street December 20, 2013
Milwaukee, Wisconsin
Contract # 360-13-0745
2
I. INTRODUCTION
Harenda Management Group (HMG) was retained by the City of Milwaukee Department of
Neighborhood Services to conduct an inspection for possible asbestos containing materials in the
dwelling at 2529-31 North 39th Street, Milwaukee, Wisconsin.
The inspection included plaster, texture, blown in insulation, fiberboard, drywall/joint
compound, ceramic tile, linoleum, window glazing compound, tar paper, ceiling tile, duct paper,
flue packing, and transite siding to determine if asbestos containing materials were present within
the space as required by US EPA NESHAP regulation 40 CFR 61 Subpart M.
II. BUILDING SURVEY
Marge Piwaron, of the City of Milwaukee Department of Neighborhood Services, authorized
HMG to conduct a building survey and to analyze samples taken during the inspection.
On December 13, 2013, HMG conducted an asbestos inspection of a two family dwelling,
scheduled for mechanical demolition, located at 2529-31 North 39th
Street, Milwaukee,
Wisconsin. The inspection was conducted by Dean Jacobsen, Wisconsin License No. AII –
14370.
The inspection was comprised of three elements:
1. A visual determination as to the extent of suspect materials within the building.
2. Sampling and documentation of observable suspect materials. Category I non-friable
materials were assumed to be asbestos containing and not sampled.
3. Quantification of observable positive materials existing within the spaces.
The results of the survey integrated with the Polarized Light Microscopy with Dispersion
Staining (PLM/DS) analysis of bulk samples taken are outlined in this document. If you have
any questions please contact HMG at (414) 383-4800.
III. THE LABORATORY
A. METHOD OF ANALYSIS
Analysis is performed by using the bulk samples for visual observation and slide preparation(s)
for microscopical examination and identification. The slides are analyzed for asbestos
(chrysotile, amosite, crodcidolite, anthophyllite, and actinolite/ tremolite), fibrous non asbestos
constituents (mineral wool, paper, etc.), and nonfibrous constituents. Asbestos is identified by
refractive indices (obtained by using dispersion staining), morphology, color, pleochroism,
birefringence, extinction characteristics, and signs of elongation. The same characteristics are
used to identify the non asbestos constituents.
The microscopist visually estimates relative amounts of each constituent using a stereoscope if
necessary. The test results are based on a visual determination of relative volume of the bulk
2 Family Dwelling SNIP Asbestos Inspection W:/Word/HMG/13 Projects/13-2000-399.2529
2529-31 North 39th
Street December 20, 2013
Milwaukee, Wisconsin
Contract # 360-13-0745
3
sample components. The results are valid only for the item tested. Current US EPA NESHAP
regulations state asbestos materials means material containing more than 1% asbestos as
determined using the method specified in Appendix E, Subpart E, 40 CFR Part 763 Section I,
Polarized Light Microscopy. Refer to 29 CFR 1926.1101 (Construction) and 29 CFR 1910.1001
(General Industry) for specific OSHA requirements.
IV. FINDINGS AND OBSERVATIONS
The materials identified as suspect asbestos containing materials (ACM) include included plaster,
texture, blown in insulation, fiberboard, drywall/joint compound, ceramic tile, linoleum, window
glazing compound, tar paper, ceiling tile, duct paper, flue packing, and transite siding. These
materials were sampled and the following results were noted:
Sample # Location and Description Results Approximate
Quantity
Homogeneous
Code
1-2529a 2nd floor – north bedroom – west wall - plaster
skim coat
Negative N/A SPl
1-2529b 2nd floor – north bedroom – west wall - plaster
base coat
Negative N/A SPl
2-2529a 2nd floor – dining room – ceiling - plaster skim coat Negative N/A SPl
2-2529b 2nd floor – dining room – ceiling - plaster base coat Negative N/A SPl
4-2529 Basement – stair – ceiling – plaster Negative N/A SPl
5-2529 1st floor – front entry – south wall – plaster Negative N/A SPl
6-2529a 1st floor – hall – ceiling – patch layer Negative N/A SPl
6-2529b 1st floor – hall – ceiling – plaster skim coat Negative N/A SPl
6-252cb 1st floor – hall – ceiling – plaster base coat Negative N/A SPl
7-2529a 1st floor – south bedroom – east wall – plaster skim
coat
Negative N/A SPl
7-2529b 1st floor – south bedroom – east wall – plaster base
coat
Negative N/A SPl
8-2529 1st floor – living room – on floor – blown in
insulation
Negative N/A MBI
9-2529 2nd floor – hall – on floor – blown in insulation Negative N/A MBI
10-2529 2nd floor – dining room – on floor – blown in
insulation
Negative N/A MBI
11-2529 1st floor – north bedroom – on floor – fiberboard Negative N/A MFB
12-2529 1st floor – north bedroom – on floor – fiberboard Negative N/A MFB
13-2529 1st floor – north bedroom – on floor – fiberboard Negative N/A MFB
14-2529 1st floor – south bedroom – north wall – drywall Negative N/A MDW
15-2529a 2nd floor – stair – south wall – joint compound Negative N/A MDW
15-2529b 2nd floor – stair – south wall – drywall Negative N/A MDW
16-2529 Attic – east wall – drywall Negative N/A MDW
17-2529 1st floor – kitchen – on south wall – yellow ceramic
tile
Negative N/A MCTMl
18-2529 1st floor – rear entry – brown linoleum Negative N/A MFLn
19-2529 1st floor – living room – east window – glazing
compound
Negative N/A MPG
20-2529 2nd floor – kitchen – west window – glazing
compound
Negative N/A MPG
21-2529 Basement – north window – glazing compound Negative N/A MPG
22-2529 1st floor – rear entry – under linoleum – tar paper Negative N/A MPT
2 Family Dwelling SNIP Asbestos Inspection W:/Word/HMG/13 Projects/13-2000-399.2529
2529-31 North 39th
Street December 20, 2013
Milwaukee, Wisconsin
Contract # 360-13-0745
4
Sample # Location and Description Results Approximate
Quantity
Homogeneous
Code
23-2529 2nd floor – kitchen – top layer west side – tan
linoleum
Negative N/A MFLt
24-2529 2nd floor – kitchen – top layer north side – tan
linoleum
Negative N/A MFLt
25-2529 2nd floor – kitchen – top layer east side – tan
linoleum
Negative N/A MFLt
26-2529a 2nd
floor – kitchen – bottom layer – yellow
linoleum
Positive 25%
Chrysotile
260 Sq. Ft MFLl
26-2529b 2nd floor – kitchen – under yellow linoleum –
leveling compound
Negative N/A MLC
27-2529 Attic – bathroom – bottom layer – cream linoleum Negative N/A MFLc
28-2529 2nd floor – bathroom – beige linoleum Negative N/A MFLe
29-2529 2nd floor – bathroom – ceiling tile Negative N/A MSCT
30-2529 2nd floor – dining room – ceiling – texture Negative N/A STX
31-2529a 2nd floor – dining room – ceiling – texture Negative N/A STX
31-2529b 2nd floor – dining room – ceiling – plaster patch Negative N/A STX
32-2529a 2nd floor – dining room – ceiling – texture Negative N/A STX
32-2529b 2nd floor – dining room – ceiling – plaster patch Negative N/A STX
33-2529 Basement – southwest on boots – duct paper Positive 65%
Chrysotile
5 Sq. Ft. TDW
34-2529 Basement – on chimney – flue packing Negative N/A TFP
35-2529 Attic – bathroom – top layer – gray linoleum Negative N/A MFLy
36-2529 Exterior – east wall – transite siding Positive 20%
Chrysotile
2,700 Sq. Ft. MTP
37-2529 Exterior – south wall – transite siding Positive 20%
Chrysotile
Reference 36-
2529
MTP
38-2529 Exterior – west wall – transite siding Positive 20%
Chrysotile
Reference 36-
2529
MTP
Notes: N/A = Not Applicable
Sq. Ft. = Square Feet
Assumed Category I Non-Friable Asbestos Containing Material:
Floor Level Location Description Approximate Quantity
Roof Dwelling Asphalt Shingles & Flashing 950 Sq. Ft.
1st Kitchen/Rear Hall Floor & Wall Mastics 70 Sq. Ft.
2nd Kitchen/Bathroom Floor Mastics 290 Sq. Ft.
Attic Bathroom Floor Mastics 40 Sq. Ft.
Homogeneous Material Codes
SPl Plaster
STX Texture
MBI Blown in Insulation
MFB Fiberboard
MPG Glazing Compound
MCTMl Yellow Ceramic Tile
MDW Drywall/Joint Compound
MFLn Brown Linoleum
MFLt Tan Linoleum
MFLl Yellow Linoleum
MFLc Cream Linoleum
MFLe Beige Linoleum
2 Family Dwelling SNIP Asbestos Inspection W:/Word/HMG/13 Projects/13-2000-399.2529
2529-31 North 39th
Street December 20, 2013
Milwaukee, Wisconsin
Contract # 360-13-0745
5
Homogeneous Material Codes
MFLy Gray Linoleum
MPT Tar Paper
MSCT Ceiling Tile
MTP Transite
TDW Duct Paper
TFP Flue Packing
Note#1: Category I – Non-Friable Asbestos Containing Materials may become friable during mechanical
demolition activities or maybe considered friable prior to demolition activities due to its current
condition.
Note#2: If additional materials are discovered during demolition that are not listed above they are to be
assumed to be asbestos containing.
Note#3: A copy of this report should be transmitted to the demolition contractor.
Note#4: Additional duct paper may be within walls and ceilings.
Note#5: Estimated cost for friable asbestos removal…
V. EXCLUSIONS
1st floor bathroom, bedroom, and kitchen floors buried in fire debris and not accessible.
Roof visible only from ground. No visible or accessible areas were excluded from the scope
of work.
HMG is not and shall not represent the building owner as its agent or representative for the
purpose of the US EPA/NESHAP and/or the WDNR/NR447 regulations, as owner/operator.
This report represents the condition of the building and its visible/accessible suspect asbestos
containing materials at the date and the times of the onsite inspection. Hidden materials or those
materials that could be present at the point of inspection, over and above those stated in the
inspection report, are the responsibility of the building owner and the demolition contractor.
VI. LIMITATIONS
The care and skill given to our procedures insures the most reliable test results possible. HMG
utilizes Quantem Laboratories for our Polarized Light Microscopy, unless otherwise specified by
the client. The findings and conclusions of HMG represent our professional opinions
extrapolated from limited data. Significant limited data is gathered during the course of the
preliminary asbestos specific site assessment. No other warranty is expressed or implied. Prior
to any abatement or renovation activities, it is recommended that HMG be provided the
opportunity to review such plans in order that the inspection and assessments contained herein
are properly interpreted and implemented.
This report and the information contained herein are prepared for the sole and exclusive use and
possession of the City of Milwaukee Department of Neighborhood Services. No other person or
entity may rely on this report or any information contained herein. Any dissemination of the
2 Family Dwelling SNIP Asbestos Inspection W:/Word/HMG/13 Projects/13-2000-399.2529
2529-31 North 39th
Street December 20, 2013
Milwaukee, Wisconsin
Contract # 360-13-0745
6
Report or any information contained herein is strictly prohibited without prior written
authorization from Harenda Management Group.
2 Family Dwelling SNIP Asbestos Inspection W:/Word/HMG/13 Projects/13-2000-399.2529
2529-31 North 39th
Street December 20, 2013
Milwaukee, Wisconsin
Contract # 360-13-0745
7
VII. PRE-DEMOLITION ENVIRONMENTAL CHECKLIST
2 Family Dwelling SNIP Asbestos Inspection W:/Word/HMG/13 Projects/13-2000-399.2529
2529-31 North 39th
Street December 20, 2013
Milwaukee, Wisconsin
Contract # 360-13-0745
8
This guide lists materials and products commonly found in buildings with examples. It is
not intended as a substitute for reading the rules and statutes and making your own
independent determination of their applicability to your demolition project. These
examples presented here do not represent an exhaustive listing of types of materials that
may be required to be removed from the building prior to demolition.
ASBESTOS
Persons conducting inspections for asbestos must hold a valid asbestos inspector
certification card issued by the State of Wisconsin, Dept. of Health & Family Services.
Please follow the Asbestos Inspection and Sampling Protocol for Buildings to be
Demolished or Renovated.
CFCs and HALONS
Equipment that may contain CFCs and Halons:
N/A Air Conditioners (roof top, room, and central)
N/A Dehumidifiers
N/A Heat Pumps
N/A Refrigerators, Freezers, Chillers
N/A Vending Machines, Food Display Cases
N/A Walk-in Coolers
N/A Water Fountains (bubblers)
N/A Fire Extinguishers (both portable and installed HALON
suppression systems)
N/A Water Coolers
LEAD
Lead or Lead Based Paint (LBP) is common in many older buildings. When recycling
construction and demolition debris, be aware that wood containing lead paint may not be
chipped and spread for landscaping. State law also prohibits the sale or transfer of any
fixture or other object containing LBP that might be placed upon any surface of a
dwelling, which is ordinarily accessible to children.
2 Family Dwelling SNIP Asbestos Inspection W:/Word/HMG/13 Projects/13-2000-399.2529
2529-31 North 39th
Street December 20, 2013
Milwaukee, Wisconsin
Contract # 360-13-0745
9
MERCURY
Products that may contain mercury:
LIGHTING
N/A Fluorescent Lights
N/A High Intensity Discharge
-Metal Halide
-High Pressure Sodium
-Mercury Vapor
N/A Neon
N/A Switches for lighting using mercury relays
-Look for any control associated with exterior or automated
lighting systems such as "Silent" wall switches.
HVAC
Check thermostats and any control associated with air handling units for switches
containing mercury.
HEATING, VENTILATING AND AIR CONDITIONING SYSTEMS
1 Old Thermostats – 1st Floor Living Room
N/A Aquastats
N/A Firestats
N/A Manometers
N/A Thermometers
BOILERS, FURNACES, HEATERS AND TANKS
N/A Mercury Flame Sensors by pilot lights
N/A Manometers, Thermometers, Gauges
N/A Pressure-trol
N/A Float or Level Controls
N/A Space Heaters
2 Family Dwelling SNIP Asbestos Inspection W:/Word/HMG/13 Projects/13-2000-399.2529
2529-31 North 39th
Street December 20, 2013
Milwaukee, Wisconsin
Contract # 360-13-0745
10
ELECTRICAL SYSTEMS – 2 Breaker Boxes in Basement
N/A Load Meters and Supply Relays
N/A Phase Splitters
N/A Microwave Relays
N/A Mercury Displacement Relays
PCBs
For electrical devices manufactured prior to 1987, it is safe to assume that they contain
PCBs and should be managed accordingly. Most equipment manufactured after this time
will say "PCB Free". The following is a list of areas in a building were PCBs may be
found:
N/A Transformers
N/A Capacitors (appliances, electronic equipment)
N/A Heat Transfer Equipment
N/A Light Ballasts
N/A Specialty Paints (such as for swimming pools or other industrial
applications)
N/A Sumps or Oil Traps (in maintenance and industrial facilities)
OTHER ENVIRONMENTAL ISSUES
N/A Hazardous Waste
N/A Oil Tanks
N/A Well Abandonment
3 Junk Auto Tires – Basement
N/A Junk Vehicles
* 10 Gallons Paint in Basement
2 Family Dwelling SNIP Asbestos Inspection W:/Word/HMG/13 Projects/13-2000-399.2529
2529-31 North 39th
Street December 20, 2013
Milwaukee, Wisconsin
Contract # 360-13-0745
11
VIII. LABORATORY RESULTS
®
2033 Heritage Park Drive I Oklahoma City, OK 73120 I (405) 755-7272/ Fax (405) 755-2058
Polarized Light Microscopy Asbestos Analysis Report
QuanTEM Lab No. 230092
Account Number: B929
Date Received:
Received By:
Date Analyzed:
Analyzed By:
Methodology:
QuanTEM Sample ID
001
OOla
002
002a
003
12/17/2013
Joanna Mueller
12/18/2013
Gayle Ooten
EPA/600/R-93/116
Client Sample ID
1-2529
2-2529
3-2529
Composition
Layered
Layered
Layered
Layered
....
No Sample in Container
004 4-2529 Homogeneous
005 5-2529 Homogeneous
Project: DNS
Client: Harenda Management Group Jolene Harenda 1237 West Bruce St. Milwaukee, WI 53204
Project Location: Milwaukee, WI
Project Number: 13-2000-399.2529
Color I Description
White
Skim Coat
Tan
Plaster
White
Skim Coat
Tan
Plaster
** **
Gray
Plaster
Gray
Plaster
Asbestos(%)
Asbestos Not Present
Asbestos Not Present
Asbestos Not Present
Asbestos Not Present
..
Asbestos Not Present
Asbestos Not Present
Non-Asbestos Fiber(%)
NA
NA
NA
NA
Not Analyzed
NA
NA
Unless otherwise noted, upon receipt the condition of the sample was acceptable for analysis.
Non Fibrous
CaC03 Paint
Quartz CaC03
CaC03 Paint
Quartz CaC03
Quartz CaC03
Quartz CaC03
QuanTEM is a NVLAP accredited PLM laboratory (Lab Code: 10 1959-Q). This report relates only to the specific items tested. NVLAP accreditation applies only to analysis performed utilizing EPA/600/M4-82-020 and EPA/600/R-93/116 methods. This report may not be used to claim product endorsement by NVLAP or any agency
of the US Government. This report may not be reproduced except in full, without the written approval of the laboratory.
Page 1 of 7
1111!!!!!!1 ..... ® -----••• LABORAlORIES
2033 Heritage Park Drive I Oklahoma City, OK 73120 I (405} 755-7272/ Fax (405} 755-2058
Polarized Light Microscopy Asbestos Analysis Report
QuanTEM Lab No. 230092 Client: Harenda Management Group
Account Number: 8929 Jolene Harenda 1237 West Bruce St.
Date Received: 12117/2013 Milwaukee, W1 53204 Received By: Joanna Mueller
Date Analyzed: 12118/2013 Project: DNS
Analyzed By: Gayle Ooten Project Location: Milwaukee, WI
Methodology: EPA/600/R-93/116 Project Number: 13-2000-399.2529
QuanTEM Client Color I Non-Asbestos Sample ID Sample ID. Composition Description Asbestos(%) Fiber(%)
006 6-2529 Layered White Asbestos Not Present NA
Texture
006a Layered White Asbestos Not Present NA
Skim Coat
006b Layered Gray Asbestos Not Present NA
Plaster
007 7-2529 Layered White Asbestos Not Present NA
Skim Coat
007a Layered Gray Asbestos Not Present NA
Plaster
008 8-2529 Homogeneous Brown Asbestos Not Present Glass Fiber 99
Insulation
009 9-2529 Homogeneous Brown Asbestos Not Present Glass Fiber 99
Insulation
Unless otherwise noted, upon receipt the condition of the sample was acceptable for analysis.
Non Fibrous
CaC03
CaC03 Paint
Quartz CaC03
Quartz CaC03
Quartz CaC03
Binder
Binder
QuanTEM is a NVLAP accredited PLM laboratory (Lab Code: 101959·0). This report relates only to the specific items tested. NVLAP accreditation applies only to analysis performed utilizing EPN600/M4-82-{)20 and EPN600/R-93/116 methods. This report may not be used to claim product endorsement by NVLAP or any agency
of the US Government. This report may not be reproduced except in full, without the written approval ofthe laboratory.
Page 2 of7
2033 Heritage Pari< Drive I Oklahoma City, OK 73120 I (405) 755-7272/ Fax (405) 755-2058
Polarized Ligbt Microscopy Asbestos Analysis Report
QuanTEM Lab No. 230092 Client: Harenda Management Group
Account Number: B929 Jolene Harenda 1237 West Bruce St.
Date Received: 12/17/2013 Milwaukee, WI 53204 Received By: Joanna Mueller
Date Analyzed: 12/1 8/2013 Project: DNS
Analyzed By: Gayle Ooten Project Location: Milwaukee, WI
Methodology: EP A/600/R-93/116 Project Number: 13-2000-399.2529
QuanTEM Client Color! Non-Asbestos Non Fibrous Sample ID SampleiD Composition Description Asbestos(%) Fiber(%)
010 10,.2529 Homogeneous Brown Asbestos Not Present Glass Fiber 99 Binder
Insulation
011 11-2529 Homogeneous Brown Asbestos Not Present Cellulose 100
Fiberboard
012 12-2529 Homogeneous Brown Asbestos Not Present Cellulose 100
Fiberboard
013 13-2529 Homogeneous Brown Asbestos Not Present Cellulose 100
Fiberboard
014 14-2529 Homogeneous White Asbestos Not Present Cellulose 20 Gypsum
Sheetrock Paint
015 15-2529 Layered White Asbestos Not Present NA CaC03
Joint Compound Paint
015a Layered White Asbestos Not Present Cellulose 20 Gypsum
Sheetrock
Unless otherwise noted, upon receipt the condition of the sample was acceptable for analysis.
QuanTEM is a NVLAP accredited PLM laboratory (Lab Code: I 01959·0). This report relates only to the specific items tested. NVLAP accreditation applies only to analysis performed utilizing EPA/600/M4-82-020 and EPA/600/R-93/116 methods. This report may not be used to claim product endorsement by NVLAP or any agency
of the US Government. This report may not be reproduced except in full, without the written approval of the laboratory.
Page 3 of7
2033 Heritage Pari< Drive 1 Oklahoma City, OK 73120 I (405) 755-72721 Fax (405) 755-2058
Polarized Light Microscopy Asbestos Analysis Report
QuanTEM Lab No. 230092 Client: Harenda Management Group
Account Number: B929 Jolene Harenda 1237 West Bruce St.
Date Received: 12/ 17/2013 Milwaukee, WI 53204 Received By: Joanna Mueller
Date Analyzed: 12/18/2013 Project: DNS
Analyzed By: Gayle Ooten Proj ect Location: Milwaukee, WI
Methodology: EPA/600/R-93/116 Project Number: 13-2000-399.2529
QuanTEM Client Color I Non-Asbestos Non Fibrous Sample ID Sample ID Composition Description Asbestos(%) Fiber (%)
016 16-2529 Homogeneous White Asbestos Not Present Cellulose 20 Gypsum
Sheetrock
017 17-2529 Homogeneous Yellow Asbestos Not Present NA Clay
Ceramic Tile
0 18 18-2529 Homogeneous Tan Asbestos Not Present Cellulose 25 CaC03
Linoleum Synthetic 10 Binder
0 19 19-2529 Homogeneous Tan Asbestos Not Present NA CaC03
Window Glazing
020 20-2529 Homogeneous Cream Asbestos Not Present NA CaC03
Window Glazing
021 2 1-2529 Homogeneous Cream Asbestos Not Present NA CaC03
Window Glazing
022 22-2529 Homogeneous Black Asbestos Not Present Cellulose 60 Tar
Tar Paper
Unless otherwise noted, upon receipt the condition of the sample was acceptable for analysis.
QuanTEM is a NVLAP accredited PLM laboratory (Lab Code: 101959-0). This report relates only to the specific items tested. NVLAP acc~ditation applies only to analysis perfonned utilizing EPA/600/M4-82-020 and EPA/600/R-9311 16 methods. This ~port may not be used to claim product endorsement by NVLAP or any agency
of the US Government. This ~port may not be reproduced except in full, without the written approval of the laboratory.
Page 4 of7
~IL .. liiiii LABORATORIES
2033 Heritage Park Drive/ Oklahoma City, OK 73120 I (405) 755-7272/ Fax (405) 755-2058
Polarized Light Microscopy Asbestos Analysis Report
QuanTEM Lab No. 230092
Account Number: B929
Date Received: 12/17/2013
Received By:
Date Analyzed:
Analyzed By:
Methodology:
QuanTEM SampleJD
023
024
025
026
026a
Joanna Mueller
12/18/2013
Gayle Ooten
EPN600/R-931116
Client Sample ID
23-2529
24-2529
25-2529
26-2529
Composition
Homogeneous
Homogeneous
Homogeneous
Layered
Layered
Client: Harenda Management Group Jolene Harenda 1237 West Bruce St. Milwaukee, WI 53204
Project: DNS
Project Location: Milwaukee, WI
Project Number: 13-2000-399.2529
Color/ Description
Tan
Flooring
Beige
Flooring
Tan
Flooring
Yellow
Sheet Vinyl
White
Leveling Compound
Asbestos (%)
Asbestos Not Present
Asbestos Not Present
Asbestos Not Present
Asbestos Present
Chrysotile 25
Asbestos Not Present
Non-Asbestos Fiber(%)
NA
NA
NA
NA
NA
Non Fibrous
Vinyl
Vinyl
Vinyl
Vinyl
CaC03
027 27-2529 Homogeneous Cream
Sheet Vinyl
Asbestos Not Present Cellulose 20 Vinyl
028 28-2529 Homogeneous Beige
Sheet Vinyl
Asbestos Not Present
Unless otherwise noted, upon receipt the condition of the sample was acceptable for analysis.
Cellulose 20 Vinyl
QuanTEM is a NVLAP accredited PLM laboratory (Lab Code: 101959-0). This report relates only to the specific items tested. NVLAP accreditation applies only to analysis perfonned utilizing EPN600/M4-82-020 and EPN600/R·93/116 methods. This report may not be used to claim product endorsement by NVLAP or any agency
of the US Government. This report may not be reproduced except in full, without the written approval of the laboratory.
Page 5 of7
2033 Heritage Park Drive I Oklahoma City, OK 73120 I (405) 755-7272/ Fax (405) 755-2058
Polarized Light Microscopy Asbestos Analysis Report
QuanTEM Lab No. 230092 Client: Harenda Management Group
Account Number: 8929 Jolene Harenda 1237 West Bruce St.
Date Received: 12/17/2013 Milwaukee, WI 53204 Received By: Joanna Mueller
Date Analyzed: 12/18/2013 Project: DNS
Analyzed By: Gayle Ooten Project Location: Milwaukee, WI Methodology: EPN600/R-93/116 Project Number: 13-2000-3 99.2529
QuanTEM Client Color I Non-Asbestos Non Fibrous Sample ID Sample ID Composition Description Asbestos(%) Fiber(%)
029 29-2529 Homogeneous White Asbestos Not Present Cellulose 30 Paint
Ceiling Tile Glass Fiber 30 Perlite
030 30-2529 Homogeneous White Asbestos Not Present NA Quartz
Plaster CaC03 Paint
031 31-2529 Layered White Asbestos Not Present NA CaC03
Texture Paint
031a Layered White Asbestos Not Present NA Quartz
Plaster CaC03
032 32-2529 Layered White Asbestos Not Present NA CaC03
Texture Paint
032a Layered White Asbestos Not Present NA Quartz
Plaster CaC03
033 33-2529 Homogeneous Gray Asbestos Present Cellulose 30 Binder
Insulation Chrysotile 65
Unless otherwise noted, upon receipt the condition of the sample was acceptable for analysis.
QuanTEM is a NVLAP accredited PLM laboratory (Lab Code: 101959-0). This report relates only to the speciftc items tested. NVLAP accreditation applies only to analysis performed utilizing EP N600/M4-82-020 and EP N600/R-931116 methods. This report may not be used to claim product endorsement by NVLAP or any agency
of the US Government. This report may not be reproduced except in full, without the written approval of the laboratory.
Page 6 of ?
M® LABORATORIES
2033 Heritage Park Drive I Oklahoma City, OK 73120 I (405) 755-7272/ Fax (405) 755-2058
Polarized Light Microscopy Asbestos Analysis Report
QuanTEM Lab No. 230092 Client: Harenda Management Group
Account Nwnber: B929 Jolene Harenda 1237 West Bruce St.
Date Received: 12/17/2013 Milwaukee, WI 53204
Received By: Joanna Mueller
Date Analyzed: 12118/2013 Project: DNS
Analyzed By: Gayle Ooten Project Location: Milwaukee, WI
Methodology: EPA/600/R-93/ 116 Project Nwnber: 13-2000-399.2529
QuanTEM Client Color I Non-Asbestos Non Fibrous Sample lD Sample ID Composition Description Asbestos (%) Fiber(%)
- - - ··
034 34-2529 Homogeneous Gray Asbestos Not Present NA Quartz
Plaster CaC03
035 35-2529 Homogeneous Beige Asbestos Not Present NA Vinyl
Flooring
036 36-2529 Homogeneous Gray Asbestos Present NA CaC03
Transite Chrysotile 20
037 37-2529 Homogeneous Gray Asbestos Present NA CaC03
Transite Chrysotile 20
038 38-2529 Homogeneous Gray Asbestos Present NA CaC03
Transite Chrysotile 20
12/19/2013 ---Date of Report
Unless otherwise noted, upon receipt the condition of the sample was acceptable for analysis.
QuanTEM is a NVLAP accredited PLM laboratory (Lab Code: 1 01959-0). This report relates only to the specific items tested. NV LAP accreditation applies only to analysis performed utilizing EPA/600/M4-82-020 and EPA/600/R-93/1 16 methods. This report may not be used to claim product endorsement by NVLAP or any agency
of the US Government. This report may not be reproduced except in full, without the written approval of the laboratory.
Page 7 of7
-. --~:~ ...... r~,.·;~,,
BORATORIES . ::;· ·
www.QuanTEM.com
ASBESTOS CHAIN OF CUSTODY 2033 Heritage Park Drive, Oklahoma City, OK 73120-7502 (800) 822-1650 • (405) 755-7272 • Fax: (405) 755-2058
LEGAL DOCUMENT- PLEASE PRINT LEGIBLY
Page 1 of ____i_ r------·-····-·-·------- . ------
... For lab Use Only
Lab No. 23oO Cfz. ~ Reject
Harenda Management Group
···•¢ontact.tilformation I
Phone: (414) 383-4800 I D~~P<Oject lnform~~lon .I cr~=:~.:.box)
Company: Project Name:
contact: Dean Jacobsen
Account#: 8929
SAMPL~D Bv: I Name:
r<-: ,....RELINQUISHED BY
1~ \!__
, 0 Other ..email r-----------------------------------~
Cell Phone: Pro]ecttocation: Milwaukee. WI
E·mall: [email protected] II Project 10: 13-2000-399.2529
Date: P.O. Number:
·· ·· .. OATe :& TIME · VIA . ~ RECEIVED BY . D~TE 4c TIME
I 2/t~ ~~~ (8Du F&£>'-- (_LA,,()_~ 12./1 '7/13 )/.'IX.
// ' · · · · . • ··REQUESTED SERVl.CE~'{PJease ·~the App~~te 8ox~s)
:P:J.M.. .··.·•···· > · · PlM~ . , .. . ,· . "· ·TEM TEM TURNAROUND TIME ~~ Bulk Analysis (EPA 600/R-93/116) 0 Vermiculite Attic Insulation 0 Air- AHERA 0 Bulk- Presence I Absence EPA600/R-93/11 6 0 Rush
(EPA 600/R~/004)
D 400 Point Count D D Air- NIOSH 7402 0 Sulk- Quantitative [weight%]- Chatfield D Same Day Other 0 lOOOPointCount 0 Air-15010312 0 Dust-Presence / Absence 0 24-Hour
0 G""m"'"' P~po.at;M r . •. . ' ' PGM . ;, .. 1 0 """""'-·-EPA 100,2 0 ""*a ....... ,. [fib•rthq.ont A5TM 05755 1?1 3 • O.y 0 Particle 10 0 I NIOSH 7400 0 Waste Water- EPA 600/4-83~3 0 Other _ lO 5 :!- Day
. No. ;!~ .· ...... ·.S~,.)P.t' 10 - j·. •. itJ. foBe ·I :(Qt~r:. .· .. :I ,. .,. . ·· ~~~(~p~lon • . • · .. · · .... , .. Vi .. blume/AreaJ Comments/ Notes .· · (10~racter$_Max) A,aly;zed · · h. .,, . ·: •'· .· . . : . . .'.< · ~s appllc.atile)
1 I -lSLC) U2l 2 ~ ~252') [] 3 3-252.9 m 4 l t ~ZSZ-9 ID s 15.-?SZ"l UJ 6 b-252':) [J 7 ~25Z9 -c 8 [
[ []1
SATURDAY SAMPLE DELIVERY - CALL TO SCHEDULE • Use this address for Saturday Delivery only: 4220 N. Santa Fe Ave., Oklahoma City, OK 73105-8517 • Mark Package HHold for Saturday Pickup"
~.MDUK.MTORIES
www.QuanTEM.com
.· Project lnfQrm.ation. · .. < . ··'
company: Harenda Management Group
No. . Sclhi~eiD . ~ToBe .
Color do thitr~c~$ Max) . • An .. ~
11 I\ --?St ') 0 12 12.. -25'-9 [ 13 13-2$2.; Q 14 •'1 . '-~' c 15 {5. ?.Sz.7 [ 16 I ~2..52:7 _b 17 11~ 2.5~ [ 18 t'8'-2529 [ 19 !j-2SZ' ~~ 20 ()o-252.'7 lD 21 Q \· 2 Sc?Y [ 22 ~2Sl9 [ 23 98 --252'? [ 24 ~'1 -252.' Q 25 ~ -2S2.'7 [ 26 Z,b.-2.SZ9 c 27 -;).7 ,252.') r 28 ()0 - 25::? Q] 29 2' - 2._52_<) c 30 3u -2SZ..."r _l!l
ASBESTOS CHAIN OF CUSTODY 2033 Heritage Park Drive, Oklahoma City, OK 73120-7502 (800) 822-1650 • (405) 755-7272 • Fax: (405) 755-2058
LEGAL DOCUMENT - PLEASE PRINT LEGIBLY
·:.· .... .. .· .. · . . . . . . . : : : ~ :
Page 2 of 3_ __ ,,., .. , _ , ,, ............ .
Reject
' I ProjectName: DNS J Project Location: Milwaukee, WI
.· 'pe$criptlon · · VoJdmei Area .· Comments l Notes : .. · ·... <• applicable} ·:, . ..·· .·· ···· :·. · . ... ..
j) J N-:>-+ \ ~st- ~'de I
I
1
I I
~
SATURDAY SAMPLE DELIVERY- CALL TO SCHEDULE • Use this address for Saturday Delivery only: 4220 N. Santa Fe Ave., Oklahoma City, OK 73105-8517 • Mark Package "Hold for Saturday Pickup"
I
i
I
I
.. ,.u~v RATO Rl ES www.QuanTEM.com
ProJect truorm.at~~m
company: Harenda Management Group
N(). ·1·· · ·· Sa. mp.le u>. · 1·.ftl .. •.··· li.o Be ... ·. ·.·j•· .•. ·· .· ' Color . · · . ·.·. . (10 Cl)aracterH"•x) Anal~ < 31 I '3 \ .--2)l.'} [41 32 I~ -252:} en 33 153-2529 [] 34 13\.{~~ [p 35 105-252.9 l] 36 13.0~~ [] 37 en- 252.<=.> rn 38 , .., ~-2SZ<"j
39
~ 0
-
40 0 -
41 0 -
42 0 -
43 0 -44 0 -45 0 -46 0 -47 D -48 D -49 0 -50 0
ASBESTOS CHAIN OF CUSTODY 2033 Heritage Park Drive, Oklahoma City, OK 73120-7502 (800) 822-1650 • (405) 755-7272 • Fax: (405) 755-2058
LEGAL DoCUMENT- PLEASE PRINT LEGIBLY
< ._ ... _
Page 3 of~ -----------------------
I Project Name: DNS j ProJect Location: Milwaukee, WI
Descflptlo:n, : -·;.
. VOlume I Area 1··.• · ·.·. Commertts 1 Notes (as~lcable) , _;,
~ Not- ~t ll~-i~
SATURDAY SAMPLE DELIVERY - CALL TO SCHEDULE • Use this address for Saturday Delivery only: 4220 N. Santa Fe Ave., Oklahoma City, OK 73105-851 7 • Mark Package "Hold for Saturday Pickup"
2 Family Dwelling SNIP Asbestos Inspection W:/Word/HMG/13 Projects/13-2000-399.2529
2529-31 North 39th
Street December 20, 2013
Milwaukee, Wisconsin
Contract # 360-13-0745
12
IX. HMG CERTIFICATION